ELATION PLATINUM BEAM 5R EXTREME USER MANUAL 120618

Elation Platinum Beam 5R Extreme - User Manual ELATION PLATINUM BEAM 5R EXTREME - USER MANUAL ELATION PLATINUM BEAM 5R EXTREME - USER MANUAL binaries adjmedia 3:

2019-02-19

: Cdb Elation Platinum Beam 5R Extreme - User Manual ELATION PLATINUM BEAM 5R EXTREME - USER MANUAL 9972 ItemRelatedFiles

Open the PDF directly: View PDF PDF.
Page Count: 40

DownloadELATION PLATINUM BEAM 5R EXTREME - USER MANUAL 120618
Open PDF In BrowserView PDF
user manual

EL AT IO N | PLATINUM BEAM 5R EXTREME | user manual

PLATINUM BEAM 5R EXTREME™

©2018 ELATION PROFESSIONAL all rights reserved. Information, specifications,
diagrams, images, and instructions herein are subject to change without notice. ELATION
PROFESSIONAL logo and identifying product names and numbers herein are trademarks
of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and
matters of copyrightable materials and information now allowed by statutory or judicial law
or hereinafter granted. Product names used in this document may be trademarks or
registered trademarks of their respective companies and are hereby acknowledged. All
non-ELATION brands and product names are trademarks or registered trademarks of their
respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages, injuries to any persons,
and direct or indirect economic loss associated with the use or reliance of any information
contained within this document, and/or as a result of the improper, unsafe, insufficient and
negligent assembly, installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com

Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu

Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000
+52 (728) 282-7070

DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated
version of this document may be available online.
Please check www.elationlighting.com for the latest revision/update of this
manual, before beginning installation and/or programming.
DMX
Channel Modes

Date

Document
Version

Software
Version

02/23/15

1

≥1.0.0

12/14/18

12/06/18

1.2

≥1.3.2

NO CHANGE

Notes
Updated manual format.

2

Updated release.

CONTENTS

General Information

4

Limited Warranty (USA Only)

5

Safety Guidelines

6

Discharge Lamp Warning

8

Maintenance Guidelines

9

Fixture Overview

10

Lamp Installation

11

Installation Guidelines

19

System Menu

23

WDMX Internal Wireless DMX Receiver Set Up

31

DMX Channel Functions And Values

33

Error Codes

36

Specifications

37

Optional Accessories

39

3

G E N E RA L I N F O RM AT I O N
INTRODUCTION
Please read and understand the instructions in this manual carefully and thoroughly before
attempting to operate this device. These instructions contain important safety and use
information.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect operating
condition. Carefully check the shipping carton for damage that may have occurred during
shipping. If the carton is damaged, carefully inspect the device for damage, and be sure all
accessories necessary to install and operate the device have arrived intact. In the event
damage has been found or parts are missing, please contact our customer support team
for further instructions. Please do not return this device to your dealer without first
contacting customer support. Please do not discard the shipping carton in the trash.
Please recycle whenever possible.
BOX CONTENTS
2 Omega Brackets
1 Power Cable
1 Safety Cable
CUSTOMER SUPPORT
Contact ELATION Service for any product related service and support needs.
Also visit forums.elationlighting.com with questions, comments or suggestions.
ELATION SERVICE USA - Monday - Friday 8:00am to 4:30pm PST
323-582-3322 | Fax 323-832-9142 | support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
+31 45 546 85 63 | Fax +31 45 546 85 96 | support@elationlighting.eu
REPLACEMENT PARTS please visit parts.elationlighting.com

I M P O R T A N T

N O T I C E !

THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT.
DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR
MANUFACTURES WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO
THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND
GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE
NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
4

LIMITED WARRANTY (USA ONLY)
A. Elation Professional hereby warrants, to the original purchaser, Elation Professional products to be free of
manufacturing defects in material and workmanship for a period of two years (730 days), and Elation
Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for
a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps
and all product accessories. This warranty shall be valid only if the product is purchased within the United
States of America, including possessions and territories. It is the owner’s responsibility to establish the date and
place of purchase by acceptable evidence, at the time service is sought. B. For warranty service, send the
product only to the Elation Professional factory. All shipping charges must be pre-paid. If the requested repairs
or service (including parts replacement) are within the terms of this warranty, Elation Professional will pay return
shipping charges only to a designated point within the United States. If any product is sent, it must be shipped
in its original package and packaging material. No accessories should be shipped with the product. If any
accessories are shipped with the product, Elation Professional shall have no liability what so ever for loss and/or
or damage to any such accessories, nor for the safe return thereof. C. This warranty is void if the product serial
number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional
concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by
anyone other than the Elation Professional factory unless prior written authorization was issued to purchaser by
Elation Professional; if the product is damaged because not properly maintained as set forth in the product
instructions, guidelines and/or user manual. D. This is not a service contract, and this warranty does not include
any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional will
replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by
reason of defects in material or workmanship. The sole responsibility of Elation Professional under this warranty
shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of
Elation Professional. All products covered by this warranty were manufactured after January 1, 1990, and bare
identifying marks to that effect. E. Elation Professional reserves the right to make changes in design and/or
performance improvements upon its products without any obligation to include these changes in any products
theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any
accessory supplied with the products described above. Except to the extent prohibited by applicable law, all
implied warranties made by Elation Professional in connection with this product, including warranties of
merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties,
whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after
said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is
expressly provided above; and under no circumstances shall Elation Professional be liable for any loss and/or
damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product. G. This
warranty is the only written warranty applicable to Elation Professional products and supersedes all prior
warranties and written descriptions of warranty terms and conditions heretofore published.

WARRANTY RETURNS
All returned service items whether under warranty or not, must be freight pre-paid and accompany a return
authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A
brief description of the problem as well as the R.A. number must also be written down on a piece of paper and
included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of
purchase invoice. Items returned without a R.A. number clearly marked on the outside of the package will be
refused and returned at customer’s expense. You may obtain a R.A. number by contacting customer support.
ONLY Use the original packaging and materials to transport the fixture in for service.

5

SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee a smooth
operation, it is important to follow all instructions and guidelines in this manual. Elation
Professional is not responsible for injury and/or damages resulting from the misuse of this
fixture due to the disregard of the information printed in this manual. Only qualified and/or
certified personnel should perform installation of this fixture and only the original rigging
parts (omega brackets) included with this fixture should be used for installation. Any
modifications to the fixture and/or the included mounting hardware will void the original
manufactures warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT.
DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID
YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM
MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF
SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID
THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY
WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK - MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
INDOOR / DRY LOCATIONS USE ONLY!
DO NOT EXPOSE FIXTURE TO RAIN AND MOISTURE!

MINIMUM DISTANCE TO OBJECTS/SURFACES
MUST BE 27 FEET (8 METERS)
MAXIMUM TEMPERATURE OF EXTERNAL
SURFACE 212° F (100°C)
6

SAFETY GUIDELINES
RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET UV
RADIATION! FIXTURE EMITS HIGH INTENSITY WAVELENGTH
OF ULTRAVIOLET UV LIGHT FROM THE UV COLOR FILTER.
WEAR PROPER EYE AND SKIN PROTECTION. AVOID
PROLONGED PERIODS OF EXPOSURE TO UV COLOR FILTER.
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING
UV PAINTS ON SKIN. AVOID DIRECT EYE AND/OR SKIN
EXPOSURE AT DISTANCES LESS THAN 11 feet (3.3m). DO NOT OPERATE FIXTURE
WITH DAMAGED/MISSING EXTERNAL COVERS. DO NOT LOOK DIRECTLY INTO THE
UV LIGHT AND/OR VIEW UV LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT
MAY CONCENTRATE THE LIGHT/RADIATION OUTPUT. INDIVIDUALS SUFFERING
FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE DIS-ORDERS, OR
INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY RECEIVE DISCOMFORT
IF EXPOSED TO THE ULTRAVIOLET UV LIGHT EMITTED FROM THE UV LED.
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow
approximately 15 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord is frayed, crimped, damaged and/or if any of the
power cord connectors are damaged and do not insert into the fixture securely with ease.
NEVER force a power cord connector into the fixture. If the power cord or any of its
connectors are damaged, replace it immediately with a new one of similar power rating.
DO NOT block any air ventilation slots.
All fan and air inlets must remain clean and never blocked.
Allow approx. 6” (15cm) between fixture and other devices or a wall for proper cooling.
When installing fixture in a suspended environment, always use mounting hardware that is no
less than M10 x 25 mm, and always install fixture with an appropriately rated safety cable.
Always disconnect fixture from main power source before performing any type of service
and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the
plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit from the interior of
the fixture. This is a normal process and is caused by excess paint in the interior of the casing
burning off from the heat associated with the lamp and will decrease gradually over time.
Consistent operational breaks will ensure fixture will function properly for many years.

7

DISCHARGE LAMP WARNING
This fixture is fitted with a DISCHARGE LAMP, which is highly
susceptible to damage if improperly handled. NEVER touch the lamp
with your bare hands, as the oil from your hands will shorten the life of
the lamp. NEVER move the fixture until the lamp has had ample time
to cool. DISCHARGE LAMPS are NOT covered under warranty
conditions. Avoid switching the fixture ON and OFF repeatedly in short
intervals, as this will reduce lamp life and intensity. To achieve the
intensity associated with discharge lamps, these lamps use gas
sealed in a high-pressure environment to emit a brilliant output.
Due to the high pressure involved with the construction of the lamp, it MAY EXPLODE
DURING PROLONGED EXTENSIVE USE. This risk is increased with age; added care is
encouraged when dealing with older lamps. Thus, the lamp must always be replaced at the
end of their recommended duty cycle. Extreme caution should be used when operating this
or any fixture fitted with a gas discharge lamp.

UV RADIATION NOTICE
THIS FIXTURE EMITS INTENSE UV RADIATION, WHICH IS HARMFUL
TO THE EYES AND SKIN. THE INTENSE LUMINANCE OF THE LAMP
CAN CAUSE SEVERE DAMAGE TO THE RETINA. NEVER OPERATE
THIS FIXTURE WITH ANY OF THE PROTECTIVE COVERS REMOVED.
THESE COVERS HAVE BEEN SPECIALLY DESIGNED TO SHIELD
AGAINST UV RADIATION.

LAMP REPLACEMENT
THE PHILIPS™ PLATINUM 5R LAMP MUST BE REPLACED EVERY 2,000
HOURS OR WHEN DAMAGED AND/OR DEFORMED!
USE ONLY GENUINE ORIGINAL PHILIPS™ LAMPS. OTHER BRAND
LAMPS WILL CAUSE DAMAGE AND WILL VOID FIXTURE WARRANTY!
DISCONNECT THE MAIN POWER SUPPLY BEFORE REPLACING LAMP!
FIXTURE MUST COOL FOR 60 MINUTES BEFORE REPLACING LAMP!
NEVER TOUCH LAMP WITH BARE HANDS, ALWAYS WEAR GLOVES!
OIL FROM HANDS WILL SHORTEN LIFE OF LAMP!
MAKE SURE ALL COVERS/PANELS ARE REPLACED/SECURED BEFORE
OPERATING FIXTURE TO PREVENT ANY RISK AND/OR DAMAGE TO
EYE RETINA FROM UV RADIATION EXPOSIURE!

8

MAINTENANCE GUIDELINES
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output, and
an extended life. The frequency of cleaning depends on the environment in which the
fixture operates: damp, smoky or particularly dirty environments can cause greater
accumulation of dirt on the fixture’s optics. Clean the external lens surface at least every 20
days with a soft cloth to avoid dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service issues to
an authorized Elation service technician. Should you need any spare parts, please order
genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:
A detailed review by an approved electrical engineer every three months, to make sure the
circuit contacts are in good condition and prevent overheating.
Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out
during normal operation resulting in damage or injury as larger parts could fall.
Check for any deformations on the housing, color lenses, rigging hardware and rigging
points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to
enter into the fixture. Damaged rigging points or unsecured rigging could cause the fixture
to fall and seriously injure a person(s).
Electric power supply cables must not show any damage, material fatigue or sediments.
NEVER remove the ground prong from the power cable.

9

FIXTURE OVERVIEW

10

1.

LED Assembly

2.

LCD Menu Function Display

3.

Wireless DMX Indicator

4.

DC Switch

5.

Microphone

6.

LEFT Button

7.

DOWN Button

8.

RIGHT Button

9.

MODE/ESC Button

10.

UP Button

11.

ENTER Button

12.

Wireless DMX Antenna

13.

Carrying Handle(s)

14.

Lamp Access/Cover Panel

15.

3pin DMX Input

16.

3pin DMX Output

17.

5pin DMX Output

18.

5pin DMX Input

19.

powerCON Input

20.

Fuse

L A M P I N S TA L L AT I O N
L A M P

R E P L A C E M E N T

Please note that due to the nature of the Philips™ Platinum 5R
Lamp and the optical path of the Elation PLATINUM BEAM 5R
EXTREME fixture, the lamp MUST BE replaced at 2,000 hours.
Use only Genuine Original Philips™ Platinum 5R Lamps. Other
brand lamps may cause damage and void warranty!
INSTALLING OR REPLACING THE LAMP
To ensure a proper/safe lamp change, carefully read all the following instructions.
LAMP PROTECTION CIRCUITRY
Because of the nature of the extreme heat associated with the Philips Platinum 5R lamp
and the tight nature of the internal optical system, it is IMPERATIVE that the lamp be
replaced every 2,000 Hours. This is done to protect the internal optical system as well as
prevent accidental lamp explosion, which could lead to hot glass particles falling from the
fixture.
FAILURE TO CHANGE THE LAMP WITHIN 300 HOUR of the 2,000 HOUR RATED LIFE,
WILL CAUSE THE FIXTURE TO AUTOMATICALLY SHUT DOWN!
At 2,000 Hours the LCD control display will begin to flash, “Replace The Lamp” and the
lamp will flicker for the first five minutes of operation. At this point the lamp has reached the
maximum rated life and should be replaced immediately. After the lamp has flickered for
about five minutes it should strike normally allowing the fixture to be used temporarily until
a replacement lamp can be installed. The fixture will continue to operate for an additional
300 hours, however the “Replace the Lamp” warning will continue to flash in the display.
Keep in mind that the flicker protection circuitry will only work for about 300 Hours (lamp
clock life of 2,000-2,300 Hours).
After 2,300 Hours the fixture will no longer respond to DMX commands and immediately
enter a hibernation mode that will electronically discontinue all fixture functionality with the
exception of a few menu commands. The fixture will continue to enter hibernation mode
until the lamp is replaced and the lamp clock has been reset. To replace the lamp follow the
safety guidelines and procedures listed on the next page.
11

LAMP SAFETY INSTRUCTIONS

•! ALWAYS replace lamp every 2,000 Hours.
•! Use only Genuine Original Philips™ Platinum 5R lamps. Other brand lamps may
cause damage and void the warranty!
•! NEVER touch the lamp with your bare hands, as the oil from your hands will
shorten the life of the lamp.
•! Always disconnect the fixture’s main power supply before replacing lamp.
•! Allow fixture to cool for at least 15 minutes before attempting any type of service.
•! Make sure ALL covers/panels are replaced/secured before operating the fixture to
prevent any risk and/or damage to eye retina from UV Radiation exposure!
LAMP INSTALLATION PROCEDURE

1.! Place fixture on a flat surface and remove (4) screws marked “A”, “B”, “C”, and “D”
and then remove rear cover plate (see image below) to access the lamp.
LAMP COVER PLATE

12

2.! Gently remove (2) Wires connected to spade terminals on base of lamp.

3.! Using two fingers on your RIGHT hand, pull the retention handle OUT and towards the
RIGHT as far as possible.

13

4.! While pulling the retention handle with your RIGHT hand, use your LEFT hand to gently
twist the lamp COUNTERCLOCKWISE to remove it from under the retention brackets.

14

5.! Using two fingers on your RIGHT hand, pull the retention handle OUT and towards the
RIGHT as far as possible.

6.! While pulling the retention handle with your RIGHT hand, use your LEFT had to gently
install the lamp under the retention brackets by holding the lamp at a slight angle and
positioning it until it is flush with the base.

15

7.! While still holding the retention handle with your RIGHT hand, gently turn the lamp
CLOCKWISE with your LEFT hand until the lamp is correctly aligned under the
retention brackets.

8.! Release the retention handle with your RIGHT hand and make sure the handle is
upright and not at an angle.

16

9.! Gently attached (2) Wires connected to spade terminals on base of lamp.

10.!Replace the lamp cover back into place by securing (4) screws marked “A”, “B”, “C”,
and “D”.

11.!Be sure to reset the LAMP HOURS in the system menu to prevent the protection
circuitry from accidently shutting off the lamp during normal operation.
12.!If the lamp protection circuitry has already been initiated and the LAMP HOURS is not
reset, the “Replace the Lamp” warning will continue to flash and fixture will eventually
shut down. To reset LAMP HOURS, see instructions on the next page.
17

LAMP HOURS RESET PROCEDURE
1.! Activate the main menu by pressing MODE/ESC and toggle to “Information”.
2.! Press ENTER and press UP or DOWN to toggle to “Time Information”.
3.! Press UP or DOWN to toggle to “L-Timer Password” and press ENTER. Then press
UP or DOWN to enter the reset pass code, “038” and press ENTER to confirm. The
display will automatically revert to “L-Timer Password”, next press UP or DOWN to
toggle down to “Clear Lamp Time”.
4.! Press ENTER and select “ON”. The lamp timer has now been reset, press MODE/ESC
to exit the menu and return to the home screen.

LAMP OPTIMIZATION
Unlike traditional discharge lamps the Philips™ Platinum 5R PRO Lamp does NOT require
optimization. The lamp orientation and optimization procedure has been preset during the
manufacturing process of the lamp.
Please remember the Philips™ Platinum 5R PRO Lamp is NOT a hot-restrike lamp
therefore, you must wait approximately 15 minutes before you can attempt to restrike the
lamp once it has been turned off.

18

I N S TA L L AT I O N G U I D E L I N E S
FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 feet (1.5m) away from any
flammable materials, decorations, pyrotechnics, etc.

ELECTRICAL

CONNECTIONS

A q ua l i fi e d e l e c tr i ci a n s h o ul d b e u s ed f or a l l
el ec tr i c al c o n n ec t i o n s a n d/ or i n s t a l l at i o n s .

MINIMUM DISTANCE TO OBJECTS/SURFACES
MUST BE 27 FEET (8 METERS)
MAXIMUM TEMPERATURE OF EXTERNAL
SURFACE 212° F (100°C)
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical
and construction codes and regulations.
Before rigging/mounting the fixture to any metal truss/structure or placing the fixture on any
surface, a professional equipment installer MUST be consulted to determine if the metal
truss/structure or surface is properly certified to safely hold the combined weight of the
fixture, clamps, cables, and accessories.
Fixture ambient operating temperature range is 14° to 113°F. (-10° to 45°C)
Do not use the fixture under or above this temperature.
Fixture should be installed in areas outside walking paths, seating areas, or away from
areas were unauthorized personnel might reach the fixture by hand.
NEVER stand directly below the fixture when rigging, removing or servicing.
Overhead fixture installation must always be secured with a secondary safety attachment,
such as an appropriately rated safety cable.
Allow approximately 15 minutes for the fixture to cool down before serving.

19

I N S TA L L AT I O N G U I D E L I N E S
MOUNTING POINTS
Overhead mounting requires extensive experience, including amongst others calculating
working load limits, installation material being used, and periodic safety inspection of all
installation material and the device. If you lack these qualifications, do not attempt the
installation yourself. Improper installation can result in bodily injury.
Fixture is fully operational only in the specific mounting positions as illustrated below.

SAFETY

CABLE

ALWAYS ATTACH A SAFETY CABLE
WHENEVER INSTALLING THIS FIXTURE
IN A SUSPENDED ENVIRONMENT TO
ENSURE THE FIXTURE WILL NOT DROP
IF THE CLAMP FAILS.

20

I N S TA L L AT I O N G U I D E L I N E S
CLAMP MOUNTING
The fixture provides a unique mounting bracket assembly that integrates the bottom of the
base, the included Omega Brackets (x2) and safety cable rigging point in one unit (see the
illustration below). When mounting this fixture to truss be sure to secure an appropriately
rated clamps to the included omega brackets using a M10 screw fitted through the center
hole of the Omega Bracket. Be sure to attach the included Safety Cable to the fixture
using the safety cable rigging point integrated in the base assembly.

SECURING
Regardless of the rigging option you choose for your fixture always be sure to secure your
fixture with a safety cable. The fixture provides a built-in rigging point for a safety cable on
the hanging bracket as illustrated above. Be sure to only use the designated rigging point
for the safety cable and never secure a safety cable to a carrying handle.
21

POTENTIAL INTERNAL FIXTURE DAMAGE FROM EXTERNAL SOURCES OF LIGHT BEAMS
External sources of light beams from direct sunlight, lighting moving head fixtures, and
lasers, which are focused directly towards the exterior housing and/or penetrate the front
lens opening of ELATION lighting fixtures, can cause severe internal damage including
burning to optics, dichroic color filters, glass and metal gobos, prisms, animation wheels,
frost filters, iris, shutters, motors, belts, wiring, discharge lamps, and LEDs.
This issue is not specific only to ELATION lighting fixtures, it is a common issue with lighting
fixtures from all manufacturers. Although there is no true way to fully prevent this issue from
happening, the guidelines below can prevent any potential damage from occurring if
followed. Contact ELATION Service for more details.

DO NOT EXPOSE THE FIXTURE AND/OR FRONT LENS OPENING TO
LIGHT BEAMS FROM DIRECT SUNLIGHT, OTHER LIGHTING MOVING
HEAD FIXTURES, AND LASERS WHILE UNPACKING, INSTALLATION,
USE, AND EXTENDED IDLE TIMES OUTDOORS.
DO NOT FOCUS A LIGHT BEAM FROM ONE LIGHTING FIXTURE
DIRECTLY TOWARDS ANOTHER.

22

SYSTEM MENU
The fixture includes an easy to navigate system menu. The control panel (see image below)
located on the front of the fixture, provides access to the main system menu and is where
all necessary system adjustments are made to the fixture. During normal operation,
pressing MODE/ESC button once will access the fixture’s main menu. Once in the main
menu you can navigate through the different functions and access the sub-menus with the
UP, DOWN, RIGHT, and LEFT buttons. Once you reach a field that requires adjusting,
press the ENTER button to activate that field and use the UP and DOWN buttons to adjust
the field. Pressing the ENTER button once more will confirm your setting. You may exit the
main menu at any time without making any adjustments by pressing the MODE/ESC
button.
To access the LCD Menu Control Display via the internal battery, press and hold the
MODE/ESC button for 3 seconds. The LCD Menu Control Display will shut OFF
automatically about 1 minute from the last button press.

23

ELATION PLATINUM BEAM 5R EXTREME
SYSTEM
MAIN MENU

FUNCTION

Specifications and features are subject to change without any prior written notice.
SUB MENU
OPTIONS / VALUES (Default Settings in BOLD)
DESCRIPTION
Set DMX Address
DMX Value
Slave Mode
Auto Program
Sound Control

Time Information

INFORMATION

LAMP
CONTROL

Temperature Info
Software Version
Lamp ON or OFF
Automatic Lamp ON
Lamp ON via DMX
Lamp OFF via DMX
Max ON at Temp
Lamp OFF Temp

Status Settings

Service Setting

PERSONALITY

MENU

Fans Control
Display Setting

A001~AXXX
ALL……
Slave1, Slave2, Slave3
Master / Alone
Master / Alone
Current Time
XXXX (Hours)
Total Run Time
XXXX (Hours)
Last Run Time
XXXX (Hours)
Lamp Hours
XXXX (Hours)
Lamp Off Time
XXXX (Minutes)
LastRun Password Password=XXX
Clean Last Run
ON / OFF
LampTime
Password=XXX
Password
ON / OFF
Clean Lamp Time
Head Temperature
XXX C° / F °
V1.0.0...
ON/OFF
ON/OFF
ON/OFF
ON/OFF
20~79°C (45°C) / 68 ~ 174°F (113°F)
80~139°C (130°C) / 176 ~ 282°F (266°F)
Address via DMX
ON/OFF
No DMX Status
Close/Hold/Auto/Music
Pan Reverse
ON/OFF
Tilt Reverse
ON/OFF
630/540/540-90 Offset
Pan Degree
Feedback
ON/OFF
Movement Speed
Speed 1 ~ 4
Mic Sensitivity
0-99%
Hibernation
OFF, 01M~99M, 15M
Password
Password=XXX
RDM PID
XXXXXX
Auto, High, Low
Shutoff Time
02~60m 05m
Display Reverse
ON/OFF
Key Lock
ON/OFF

Temperature C/F

Celsius/Fahrenheit

Initial Status

PAN =XXX
WDMX OFF
Activate WDMX
Act & Data Out
Clean WDMX Memo
ON/OFF

Wireless DMX
Reset Default

24

DMX Address Setting
DMX Value Display
Slave Setting
Auto Program
Sound Control
Fixture Run Time From Power ON
Fixture Total Run Time
Clear Fixture Last Run Time
Lamp Total Run Time
Lamp OFF Time
Password 038
Reset Fixture Last Run Time
Password 038
Reset Lamp Run Time
Temperature in Fixture Head
Software Version
Lamp ON/OFF
Lamp ON/OFF when Power ON
Lamp ON via DMX
Lamp OFF via DMX
Lamp ON at Temp
Lamp OFF at Temp
Address Via DMX
Auto Run If No DMX
Pan Reverse Movement
Tilt Reverse Movement
Pan Degree Select
Movement Feedback
Movement Mode Select
Sensitivity of Microphone
Stand By Mode
Service Password 050
RDM PID Code
Fans Speed Select
Display Shut Off Time
Display Reverse 180º
Key Lock
Temperature Switch Between C˚/
F˚
Initial Effect Position
De-activate WDMX
Activate WDMX
Act & Data Out
Reset Wireless DMX Mem
Restore factory settings

ELATION PLATINUM BEAM 5R EXTREME
SYSTEM
MAIN MENU

Reset
Function

Effect Adjust

MENU

Specifications and features are subject to change without any prior written notice.
OPTIONS / VALUES (Default Settings in
SUB MENU
DESCRIPTION
BOLD)

Reset All
Reset Pan^Tilt
Reset Colors
Reset Gobos
Reset Shutter
Reset Others
Test Channel
Manual Control
Calibration

User Mode

User Mode Set

Edit User Mode
Select Programs

Edit Program

Edit Program
Edit Scenes
Record Controller

PAN ……
PAN =XXX, ......
Calibrate Password
Standard Mode
Basic Mode
Extended Mode
User Mode A
User Mode B
User Mode C
Max Channel = XX
PAN = CH01
Auto Pro Part1 = Program 1~10 (Program 1)
Auto Pro Part2 = Program 1~10 (Program 2)
Auto Pro Part3 = Program 1~10 (Program 3)
Program 1
Program Test
:
Step 01=SCxxx
Program 10
Step 64=SCxxx
Pan,Tilt,……
Scene 001
--Fade Time-~
--Scene Time-Scene 250
Input By Outside
XX~XX

Reset All Motors
Reset Pan/Tilt
Reset Color Wheel
Reset Gobos
Reset Shutter and/or Dimmer
Reset Other Motors
Test function
Fine Adjustments
Password 050
DMX Channel Modes

User Defined Channel Assignment
Edits User Defined
Channel Assignments
Select Programs To Be Run
Testing Program
Program In Loop
Save and Exit
Save and Automatically Return
Manual Scenes Edit
Stores Scenes via Ext DMX Console
Automatic Scenes Recorder

FUNCTION - Auto Program
Define fixture mode (Master or Alone) for running Auto Programs. Select desired internal
programs under “Select Program”, set the number of steps under “Edit Program”, and
edit individual scenes under “Edit Scenes”.
This counter can be reset.
LAMP CONTROL - Lamp ON at Temp
The fixture is designed to shut the lamp OFF when an excessive temperature is sensed
inside the head by the on-board CPU. The lamp is shut OFF to prevent damage to the lamp
and avoid possible internal damage to the fixture head.
This function sets the MIN internal operating temperature of the fixture head before the
lamp will restrike after the lamp has been automatically shut OFF.
25

LAMP CONTROL - Lamp OFF Temp
The fixture is designed to shut the lamp OFF when an excessive temperature is sensed
inside the head by the on-board CPU. The lamp is shut OFF to prevent damage to the lamp
and avoid possible internal damage to the fixture head.
This function sets the MAX internal operating temperature of the fixture head when the
lamp will automatically be shut OFF.
PERSONALITY - Status Settings - Address Via DMX
When ON, define the desired DMX address via an external controller.
1.! Connect the fixture to the external controller and power ON.
2.! Set the DMX value of Channel 1 on the controller to (7).
3.! Set the DMX value of Channel 2 on the controller to (7) or (8).
When set to (7), the DMX address can be set between (1) and (255).
When set to (8), the DMX address can be set between (256) and (511).
4.! Using Channel 3 on the controller set the desired DMX address of the fixture.
Example 1:
If the desired DMX address is 57, set Channel 1 to a value of (7), set Channel 2 to a
value of (7), and then set Channel 3 to a value of (57).
Example 2:
If the desired DMX address is 420, set Channel 1 to a value of (7), set Channel 2 to a
value of (8), and then set Channel 3 to a value of (164). (256+164=420)
5.! After setting Channel 3 to the desired DMX address value, wait for approximately 20
seconds for the fixture to complete the address reset function.
EFFECT ADJUST – Manual Control
Select and manually test and fine adjust each individual channel function
Independently from DMX control board. This function will center PAN and TILT motors and
set dimmer to 100%. PAN and TILT functions will still operate if the fixture needs to be
positioned to a flat clear surface. With the individual functions, you can focus the light on a
flat surface (wall) and perform fine adjustments.

26

EFFECT ADJUST – Calibration
ONLY QUALIFIED TECHNICIANS SHO ULD PERFORM THI S FUNCTION.
This function allows small adjustments to be made to the effect wheels (Color, Gobo,
Shutter, etc.) to compensate for ware or in the event a sensor has been knocked slightly out
of place. Because improper use of this function can result in undesired operation this
function has been password protected. The password is 050 and must be entered each
time the calibration menu function is entered. Because calibration is an extremely delicate
procedure, instructions on performing this action are left out of this manual. For a first time
calibrator, please contact our customer support team for step-by-step instructions.
USER MODE SET – User Mode
Select operating mode, which includes DMX Channel and User defined modes.
USER MODE SET – Edit User Mode
Create user defined channel orders allowing the fixture to match the channel order of other
fixtures on the market for easier operation. A total of three user modes may be configured:
User Mode A, User Mode B, and User Mode C.
EDIT PROGRAM – Select Program
Select one of the (10) user defined internal Auto Programs.
EDIT PROGRAM – Edit Program
Edit any of the (10) user defined internal Auto Programs.
EDIT PROGRAM – Edit Scenes
Edit any of the scenes of the internal Auto Programs.
EDIT PROGRAM – Record Controller
The fixture features an integrated DMX-recorder by which you can transmit the
programmed scenes from your DMX-controller to the moving head. Adjust the desired
scene numbers via the encoder (from – to). When you call up the scenes at your controller,
they will automatically be transmitted to the moving head.

27

EDIT PROGRAM – Record Controller – Working With Built In Programs
A Master unit can send up to 3 different data groups to the Slave units, i.e. a Master unit
can start 3 different Slave units, which run 3 different programs. The Master unit sends the
3 program parts in a continuous loop.

The Slave unit receives data from the Master unit according to the group which the Slave
unit was assigned to. If e.g. a Slave unit is set to “Slave 1” in the menu “Set to Slave”, the
Master unit sends “Auto Program Part 1” to the Slave unit.
If set to “Slave 2”, the Slave unit receives “Auto Program Part 2”.
To start an Auto Program proceed as follows:

1. Slave Setting
• Select “Function Mode”.
• Press ENTER to confirm.
• Select “Set to Slave”.
• Press ENTER to confirm.
• Select “Slave 1”, “Slave 2” or “Slave 3”.
• Press ENTER to confirm.
• Press MODE/ESC in order to return to the main menu.
2. Automatic Program Run
• Select “Function Mode”.
• Press ENTER to confirm.
• Select “Auto Program”.
• Press ENTER to confirm.
• Select “Master” or “Alone”.
• Press ENTER to confirm.
• Press MODE/ESC in order to return to the main menu.
28

EDIT PROGRAM – Record Controller – Working With Built-In Program [continued]
3. Program Selection for Auto Pro Part
• Select “Edit Program”.
• Press ENTER to confirm.
• Select “Select Programs”.
• Press ENTER to confirm.
• Select “Auto Pro Part 1”, “Auto Pro Part 2” or “Auto Pro Part 3”, and select which
Slave program is to be sent. Selection “Part 1” means, that the Slave unit runs the
same program as the master units.
• Press ENTER to confirm.
• Press MODE/ESC in order to return to the main menu.
4. Program Selection for Edit Program
• Select “Edit Program”.
• Press ENTER to confirm.
• Select “Edit Program”.
• Press ENTER to confirm.
• Select the desired program. With this function you can edit specific scenes into a
specific program.
• Press ENTER to confirm.
• Press MODE/ESC in order to return to the main menu.
5. Automatic Scene Recording
• Select “Edit Program”.
• Press ENTER to confirm.
• Select “Edit Scenes”.
• Select desired scene numbers. A maximum of 250 scenes can be programmed.
• Press ENTER to confirm.
• Press MODE/ESC in order to return to the main menu.

29

EDIT PROGRAM – Record Controller – Working With Built-In Program [continued]
Example:
Program 2 includes scenes: 10, 11, 12, & 13
Program 4 includes scenes: 8, 9, & 10
Program 6 includes scenes: 12, 13, 14, & 15
Auto Pro Part 1 is Program 2
Auto Pro Part 2 is Program 3
Auto Pro Part 3 is Program 6
The 3 Slave groups run the Auto Program in certain time segments, as shown in the
following picture:

30

WDMX INTERNAL WIRELESS DMX RECEIVER SET UP
The fixture is equipped with an internal Wireless DMX Receiver, which is fully compatible
with an Elation Wireless DMX System. Access the “Wireless DMX” sub menu from the
“PERSONALITY” menu, then select desired WDMX connection function, which includes:
WDMX Off - Turn OFF Wireless DMX
Activate WDMX - Turn ON Wireless DMX
Act & Data Out - Turn ON Wireless DMX and send DMX data to wired 3/5pin outputs
Clean WDMX Memo - Clear WDMX memory
When the WDMX system is “Activated” the internal DMX “IN” XLR jacks are OFF. However
the internal DMX “OUT” XLR jacks will function normally. If the fixture is powered ON with
the internal WDMX system “Activated”, it will automatically scan for a wireless DMX signal
from an Elation Wireless Transmitter.
IF NO WIRELESS SIGNAL AVAILABLE, FIXTURE WILL SEND DATA TO 3/5PIN OUTPUTS!

W A R N I N G !
NEVER CONNECT A FIXTURE TO A CONTROLLER VIA A DMX CABLE
WHEN THE WDMX SYSTEM IS IN USE. THIS COULD CAUSE SERIOUS
DAMAGE TO THE CONTROLLER!!
SETTING UP THE WDMX SYSTEM
Follow the instructions included with the Elation EWDMX Transmitter and connect it to
the output of your DMX controller. To sync your fixture with the Elation EWDMX
Transmitter follow the steps below:
•! Initially, the Wireless Indicator on the fixture control panel should be solid RED.
•! Press and hold the configuration button on your EWDMX Transmitter for about 3
seconds. The RED/GREEN LED indicators on the EWDMX Transmitter and the fixture
should begin to flash rapidly for about 5-10 seconds while the two systems pair.
•! Once the fixture is paired with the EWDMX Transmitter (T1), the Wireless status
indicators on the both the fixture and the EWDMX Transmitter will stop flashing and
glow solid GREEN. If paring is unsuccessful repeat the process until paring is secured.
•! The fixture will store the pairing information inside a nondestructive memory bank once
a link is created between the fixture and an EWDMX Transmitter. The fixture will
remember the paired EWDMX Transmitter even if the fixture is turned OFF for
extended periods of time.

31

WDMX INTERNAL WIRELESS DMX RECEIVER SET UP
CLEARING EWDMX TRANSMITTER LINK
•! Access the “Wireless DMX” sub menu from the “PERSONALITY” menu, and then
select “Clear WDMX Memo” to clear any existing link between the fixture and a
EWDMX Transmitter. The Wireless indictor on the fixture will turn solid RED when the
link is severed.
•! You may also clear the link directly from the EWDMX Transmitter. First, be sure the
fixture(s) is powered ON, and then hold down the configuration button on the EWDMX
Transmitter for as least 5 seconds. This will automatically clear the link between the
EWDMX Transmitter and any fixture that is powered ON. All EWDMX indictors will
glow solid RED if the procedure was successful.
FIXTURE WIRELESS INDICATOR

RED/GREEN (Rapid Flashing) = Syncing to an EWDMX Transmitter.
RED/GREEN (Slow Flashing) = Paired with an EWDMX Transmitter but
not receiving a DMX signal from a controller.
GREEN (Solid) = Paired with an EWDMX Transmitter and receiving
DMX data.
RED (Solid) = Not paired with an EWDMX Transmitter (FREE).

32

DMX CHANNEL FUNCTIONS AND VALUES
ELATION PLATINUM BEAM 5R EXTREME
DMX Channel Values / Functions (18 DMX Channels)
Specifications are subject to change without any prior written notice.
*Rotation direction (Clockwise or Counterclockwise) of COLOR, GOBO, and PRISM effects depends on the orientation of the fixture head.

MODE / CHANNEL
BASIC

STAND

EXTEND

1

1

1

2
2

2
3

4

3
4

VALUE

FUNCTION
PAN MOVEMENT [8 BIT]

0-255

PAN Movement By 630/540
PAN FINE MOVEMENT [16 BIT]

0-255

Fine Control of PAN Movement
TILT MOVEMENT [8 BIT]

0-255

TILT Movement By 270
TILT MOVEMENT [16 BIT]

0-255

Fine Control of TILT Movement
COLOR WHEEL

0-10

3

5

5

6

11-21

OPEN / WHITE
RED

22-32

BLUE

33-43

GREEN

44-54

YELLOW

55-65

MAGENTA

66-76

LIGHT BLUE

77-87

ORANGE

88-98

PURPLE

99-109

UV FILTER

110-120

CTO

121-127

CTB

128-189

*Clockwise Color Rotation from FAST to SLOW

190-193

NO Rotation

194-255

*Counterclockwise Color Rotation from SLOW to FAST
COLOR WHEEL FINE ADJUSTMENT

0-255

FINE Adjustment of Color Wheel to Any Position
ROTATING GOBOS, CONTINOUS ROTATION

0-9

4

6

7

OPEN / WHITE

10-19

Rotating Gobo 1

20-29

Rotating Gobo 2

30-39

Rotating Gobo 3

40-49

Rotating Gobo 4

50-59

Rotating Gobo 5

60-69

Rotating Gobo 6

70-79

Rotating Gobo 7

80-89

Rotating Gobo 8

90-104

Rotating Gobo 1 Shake

105-119

Rotating Gobo 2 Shake

120-134

Rotating Gobo 3 Shake

135-149

Rotating Gobo 4 Shake

150-164

Rotating Gobo 5 Shake

165-179

Rotating Gobo 6 Shake

180-194

Rotating Gobo 7 Shake

195-209

Rotating Gobo 8 Shake

210-255

Gobo Wheel Continuous Rotation from SLOW to FAST

33

ELATION PLATINUM BEAM 5R EXTREME
DMX Channel Values / Functions (18 DMX Channels)
Specifications are subject to change without any prior written notice.
*Rotation direction (Clockwise or Counterclockwise) of COLOR, GOBO, and PRISM effects depends on the orientation of the fixture head.

MODE / CHANNEL
BASIC

STND

VALUE

FUNCTION

EXTEND
9

ROTATING GOBOS, FINE INDEX ROTATION
0-255

Gobo Rotation FINE Indexing
ROTATING GOBOS, INDEX ROTATION

0-127
5

7

8

Gobo Indexing

128-189

*Clockwise Gobo Rotation from FAST TO SLOW

190-193

NO Rotation

194-255

*Counterclockwise Gobo Rotation from SLOW to FAST
ROTATING PRISM, PRISM / GOBO MACROS

6

7

8

9

10

11
12

0-3

OPEN

4-63

8-FACET PRISM *Clockwise Rotation from FAST to SLOW

64-67

NO Rotation

68-127

8-FACET PRISM *Counterclockwise Rotation from SLOW to FAST

128-135

Macro 1

136-143

Macro 2

144-151

Macro 3

152-159

Macro 4

160-167

Macro 5

168-175

Macro 6

176-183

Macro 7

184-191

Macro 8

192-199

Macro 9

200-207

Macro 10

208-215

Macro 11

216-223

Macro 12

224-231

Macro 13

232-239

Macro 14

240-247

Macro 15

248-255

Macro 16
FOCUS

0-255

Continuous Adjustment from NEAR to FAR
FOCUS FINE

0-255

Continuous FINE Focus Adjustment
SHUTTER, STROBE

8

9

10

11

13

14
15

0-31

Shutter CLOSED

32-63

NO Function (Shutter OPEN)

64-95

Strobe Effect SLOW to FAST

96-127

NO Function (Shutter OPEN)

128-159

Pulse Effect In Sequences

160-191

NO Function (Shutter OPEN)

192-223

Random Strobe Effect SLOW to FAST

224-255

NO Function (Shutter Open)
DIMMER INTENSITY

0-255

Intensity 0 to 100%
DIMMER INTENSITY FINE

0-255

Dimmer Intensity FINE Adjustment

34

ELATION PLATINUM BEAM 5R EXTREME
DMX Channel Values / Functions (18 DMX Channels)
Specifications are subject to change without any prior written notice.
*Rotation direction (Clockwise or Counterclockwise) of COLOR, GOBO, and PRISM effects depends on the orientation of the fixture head.

MODE / CHANNEL
BASIC

STND

EXTEND

10

12

16

VALUE

FUNCTION
FROST

0-127

Disable FROST

128-255

Enable FROST
PAN / TILT MOVEMENT SPEED

0-225
11

13

17

MAX to MIN Speed

226-235

Blackout by Movement

236-245

Blackout by ALL Wheel Changing

246-255

NO Function
LAMP ON/OFF, RESET, INTERNAL PROGRAMS

12

14

18

0-19

COLOR & GOBO Change Normal

20-29

COLOR Change to Any Position

30-39

COLOR & GOBO Change to Any Position

40-59

LAMP ON

60-79

LAMP Switch OFF

80-84

ALL Motor Reset

85-87

SCAN Motor Reset

88-90

COLORS Motor Reset

91-93

GOBO Motor Reset

94-96

SHUTTER & DIMMER Motor Reset

97-99

OTHER Motor Reset

100-119

Internal Program 1

120-139

Internal Program 2

140-159

Internal Program 3

160-179

Internal Program 4

180-199

Internal Program 5

200-219

Internal Program 6

220-239

Internal Program 7

240-255

Auto Program by Sound Control

35

ERROR CODES
When power is applied, the unit will automatically enter a “Reset/Test” mode. This mode
brings all the internal motors to a home position. If there is an internal problem with one or
more of the motors an error code will flash in the display in the form of “XXer” were as XX
will represent a function number. For example, when the display shows “0Er” it means
there is some type of error with the Pan motor. If there are multiple errors during the start-up
process they will all flash in the display. For example: if the fixtures has errors on Channel 1,
2, and 5 all at the same time, you will see the error message “01Er”, “02Er”, and ”05Er”
flash repeated 5 times.
If an error does occur during the initial start-up procedure the fixture will self-generate a
second reset signal and try to realign all the motors and correct the errors. If the error
persists after a second attempt a third attempt will be made. If after a third attempt all the
errors have not been corrected the fixture will make the following determinations:
•! 3 or More Errors - The fixture cannot function properly with three or more errors
therefore the fixture will place itself in a stand-by mode until subsequent repairs can be
made.
•! Less Than 3 Errors - The fixture has less than 3 errors; therefore most other functions
will work properly. The fixture will attempt to operate normally until the errors can be
correct by a technician. The errors in question will remain flashing in the display as a
reminder of internal errors.

PAN Er

Gobo Rot. 1 Er

TILT Er

Focus Er

Color Wheel Er

Gobo Wheel 1 Er

36

S P E C I F I C AT I O N S
SOURCE
189W Platinum 5R Lamp
2,000 Hour Average Life*
*May vary depending on several factors including but not limited to:
Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.

EFFECTS
Frost
Motorized Focus
Strobe (1-18 fps)
Electronic Dimming: 0% - 100%
8 Facet Rotating Prisms and Macros
COLOR
(12) Colors Including UV, CTO, CTB
GOBOS
(8) Metal Rotating, Indexing, Interchangeable Gobos
CONTROL / CONNECTIONS
(3) DMX Channel Modes (12 / 14 / 18)
Remote Device Management
Pan Movement: 540°/630° / Tilt Movement: 270°
6 Button Control Panel
Full Color 180° Reversible LCD Menu Display
16 Bit 3-Phase Pan/Tilt Motors
3pin & 5pin DMX In/Out
powerCON In
Internal EWDMX Wireless DMX Receiver
SIZE / WEIGHT
Length: 13.9” (352mm)
Width: 13.0” (329mm)
Vertical Height: 20.0” (509mm)
Weight: 44.0 lbs. (20.0 kg)
ELECTRICAL / THERMAL
AC 100-240V - 50/60Hz
350W Max Power Consumption
14°F to 113°F (-10°C to 45°C)
APPROVALS
CE | IP20

Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

37

COLORS AND GOBOS

**IMPORTANT NOTICE REGARDING GOBO DIMENSIONS AND CUSTOM GOBOS
OD = Outside Diameter | ID = Image Diameter
Due to varying manufacturing processes, it is highly recommended to provide a gobo and
holder sample from the fixture to 3rd party custom gobo vendors for accurate sizing.

PHOTOMETRIC DATA

Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

38

FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation.
This device uses and can radiate radio frequency energy and, if not installed and used in accordance with the
included instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this device does cause harmful
interference to radio or television reception, which can be determined by turning the device off and on, the
user is encouraged to try to correct the interference by one or more of the following methods:
•! Reorient or relocate the device.
•! Increase the separation between the device and the receiver.
•! Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
•! Consult the dealer or an experienced radio/TV technician for help.
DIMENSIONAL DRAWINGS

Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

OPTIONAL ACCESSORIES
ORDER CODE

ITEM

ZB-MSD PLATINUM 5R

Philips MSD Platinum 5R Lamp

TRIGGER CLAMP

Heavy Duty Wrap Around Hook Style Clamp

DRCPLAT

Dual Flight Case For Platinum Beam 5R EXTREME™

DRCPLATQUAD

Quad Flight Case For Platinum Beam 5R EXTREME™

EWDMXSYSTEM

Wireless DMX System (1 Transmitter, 1 Receiver)

AC3PDMX5PRO

5 ft. (1.5m) 3pin PRO DMX Cable

AC5PDMX5PRO

5 ft. (1.5m) 5pin PRO DMX Cable
Additional Cable Lengths Available
39



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
Linearized                      : No
XMP Toolkit                     : XMP Core 5.4.0
Modify Date                     : 2018:12:06 15:19:03-08:00
Creator Tool                    : Word
Create Date                     : 2018:12:06 23:18:22Z
Metadata Date                   : 2018:12:06 15:19:03-08:00
Producer                        : Mac OS X 10.10.5 Quartz PDFContext
Creator                         : cmg
Format                          : application/pdf
Title                           : ELATION PLATINUM BEAM 5R EXTREME - USER MANUAL 120618
Document ID                     : uuid:e76d761d-6c95-b44e-a4af-2f381fd55e51
Instance ID                     : uuid:619769d3-dcc9-a64f-87f4-c638b2425534
Page Count                      : 40
PDF Version                     : 1.4
Author                          : cmg
EXIF Metadata provided by EXIF.tools

Navigation menu