Chris Harvey
From: Chris Harvey
Sent: Friday, June 01, 2001 9:07 AM
To: Liming Xu; Greg Czumak; Marianne Bosley
Subject: RE: Celletra
I agree with Liming's comments.
1) The Bandedge compliance does not apply to this device which is an amplifier, because it is dependant on the BTS that
it is connected to.
2) The Radiated Spurious Emissions are listed in the report as being >30dB below the limit and thus not reported. I
verified on the datasheet that this test was performed with no measurable emissions. No further testing is necessary.
3) we will get the customer to modify the manual in accordance with discussions between Liming and Israel.
This spplication is ready to Grant.
-----Original Message-----
From: Liming Xu
Sent: Thursday, May 31, 2001 9:26 PM
To: Chris Harvey; Greg Czumak; Marianne Bosley
Subject: RE: Celletra
Please my answer follow each questions
-----Original Message-----
From: Marianne Bosley
Sent: Thursday, May 31, 2001 4:47 PM
To: Liming Xu
Subject: FW: Celletra
Here it is Liming, Greg said he would be back to reviewing around 9PM. his phone number is 610-380-1857.
Marianne T. Bosley
EMC Administrator
410-354-3300, ext. 412
-----Original Message-----
From: Fr. Gregory Czumak [SMTP:Gregory.Czumak@verizon.net]
Sent: Thursday, May 31, 2001 4:12 PM
To: Marianne Bosley; charvey@metlabs.com
Subject: Re: Celletra
Technical review complete- RT questions below. Checklists copied below RT questions, and
also attached.
RT questions:
1. The output plots indicate noncompliance at the bandedge if tuned to a bandedge channel,
however, no video averaging was employed, as is permitted for CDMA emissions. Please
submit output plots using video averaging in order to demonstrate bandedge compliance.
Answer: Please notice this is an amplifier ( or signal repeater not a BTS).
90% of amplifiers do not have bandedge channel frequency assignment,
So, we have nothing to test on the bandedge channel emissions ( so as this project).
10% of amplifiers do have bandedge channel frequency assignment to associate with
2
specified BTS, only this case we need to test emissions on the bandedge channel frequency.
2. Please submit radiated spurious emissions.
Answer: We ( Chris, you and me) discussed this issue several times,
we do not submit radiated spur emissions for Pt.24 report ( please reff to page 4
statement which was you pepared).
we do submit radiated spur emissions for Pt.15 report
Please let me know if you have new idear for this issue.
3. The technical information contains an apparent discrepancy. The active antenna gain is
listed as 13 dBi, so, in conjunction with a conducted output power of 33 dBm, the EIRP would
be 46 dBm, or 40W. However, the technical description goes to list the EIRP as 53 dBm, or
200 W. Please clarify.
Answer: I will forward this issue to the client again, because I discussed this issue with client
on 5/17/01 they said they will correct this on the manual.
Certification Checklist For Licensed Transmitters
Applicant's Name: _Celletra___________ Test Firm: __MET Labs____
FCC ID: ___PNQCBPABMONGXNA55 ____ EA # ________
Equipment Functional Description: _PCS Repeater__________________ Equipment Class
Correct (Y / N)__PCB
Administrative Information
Check off:
a. Associated Pending Application? (Y/N)_No__
b. Confidentiality Requested? (Y / N) _Yes__ Letter with details included? (Y/N)__Yes___
c. Statement / letter supplied for special requirements or inter-agency coordination?
__No________ Date of letter_________________
Technical Information
(To make the Grant line entry)
Enter:
a. Rule Parts ___24E__________________________________
b. Frequency Range ____1930-1990___________________________
c. Power Output ____2.0 W_conducted, EIRP = ?_____________________________
(Levels - variable or switched?) _________________
Antenna connector or integral antenna__integral__________
d. Frequency Tolerance Rating ____n/a___(Repeater)_______________
3
e. Emissions ___Authorized for use with F9W
emissions__________________________________
Necessary Bandwidth Values Justified? (Y/N)_n/a______
Emission Types Justified? (Y/N) __n/a_______________
Descriptive Information (Section 2.1033(c)(1))
Check off:
a. Instruction Manual ___Yes_______________________
b. DC Voltages and Currents __yes_____________________
c. Tune-up Procedure ___ yes _________________________
d. Circuit diagram / Block Diagram Yes _______________
e. Photographs: Internal__Yes__ External__Yes___
Technical Report (Sections 2.1046 thru 2.1057)
Check off and compare with Radio Service Rule requirements:
a. Power output: ERP or Conducted __2 W conducted, EIRP = ?________
b. Audio Frequency Response M=___n/a_______
c. Modulation Limiting D=___n/a______________
d. Audio Low Pass Filter Response Plot _n/a_____
e. Transient Frequency Response (Part 90.214) _ n/a _____ / (Attack time for Part 95 CB) _
n/a _____
f. Occupied Bandwidth plots for each emission? (Y/N)_Y____ (VBW & ResBW = __30
______KHz)
Properly Modulated (Y / N) __Y_______
g. Conducted Spurious __yes_____________________
h. Radiated Spurious ___NO_____________________
i. Frequency Stability vs. Voltage (+/- 15% or Battery Endpoint) _n/a____
j. Frequency Stability vs. Temperature (-30 to + 50 C) __n/a___________
Notes
Subpart (E) - Broadband PCS
4
Is the device operating in the following operating frequency band?
__yes____ Blocks from 1850 - 1990 MHz
Are the following General Technical Requirements met?
_ yes _____Section 24.232 - Power output (EIRP)
_n/a_____Section 24.235 - Frequency Stability
? _____Section 24.238 - Emission limits
Are the following Special Requirements met?
__n/a____MPE or SAR evaluation required for portable and mobile units per
Sections 2.1091 and 2.1093.
Special Interpretations:
Power output for units with built-in antenna to be listed as EIRP.
Otherwise same as Cellular
Marianne Bosley wrote:
Just disregard anything you got there. I resent ALL documents to your
mailbox here.
Marianne T. Bosley
EMC Administrator
410-354-3300, ext. 412
> -----Original Message-----
> From: Fr. Gregory Czumak [SMTP:Gregory.Czumak@verizon.net]
> Sent: Wednesday, May 30, 2001 10:22 AM
> To: Marianne Bosley
> Subject: Re: Celletra
>
> Hi Marianne,
>
> I did receive (here at home) 2 Celletra emails a few minutes ago, with a
> total
> of 7 attachments between them. I don't know why they're getting kicked
> back to
> you as undelivered(?). And, btw, I am able again to get into my metlabs
> inbox-
> Patrick and I worked it out...please thank him for me. I will try to
> begin the
5
> Celletra app later today, or if not, then tomorrow. I must leave now to
> visit
> an ill parishioner, just home from the ICU of the hospital.
>
> Gregory
>
> Marianne Bosley wrote:
>
> > Hi Greg,
> >
> > Well, this one is a little more complicated. I've already had two
> returned
> > to me - I was trying to break it down. So, Please check your metlab
> mailbox
> > - I sent everything there. Things to remember - this is a priority
> (Chris
> > promised Friday to have grant that is of course unless something major
> was
> > uncovered. ) Also, I sent both Pt. 24 check lists for you to choose
> which
> > one applied. Also there is the general licensed transmitter one
> attached.
> >
> > Marianne T. Bosley
> > EMC Administrator
> > 410-354-3300, ext. 412
<< File: ATT06286.ATT >> << File: ATT06287.ATT >>