Centrak DM31Y MULTI-MODE VIRTUAL WALL ITD-318 &IT-313C; User Manual Microsoft PowerPoint IT 313 Monitor 1 03x

Centrak, Inc. MULTI-MODE VIRTUAL WALL ITD-318 &IT-313C; Microsoft PowerPoint IT 313 Monitor 1 03x

Contents

User Manual 1

©CenTrak2013.AllRightsReserved.ProprietaryandConfidential.1/03CenTrak,Inc.5CaufieldPlace,Suite102Newtown,PA18940t:215‐860‐2928e:sales@centrak.comwww.centrak.comCenTrak MonitorIT‐313*•CenTrak Gen2IR™Technologyforaccurateroom‐levellocationand2‐waycommunicationwithStarbasestations•BatteryOperated– Standard5+yearstypical•BatteryOperated– ExtendedLifeOption10+yearstypical•Canbeconfiguredandmonitoredbycentralserverforsuperiorcontrol•Simpletoinstallceilingtilemountingbracket,noin‐roomwiringrequiredTheMonitorisanIR(infrared)signalingunitusedwithIR‐enabledtagstoprovideamethodoflocatingtaggedassetsorpeople.EachMonitortransmitsaninfraredpulsepatterncontainingauniquelocationcode.TheCenTrakproprietaryIRprotocolachievesamarkedimprovementoverconventionalIRprotocolsthatweredesignedforremotecontrolapplications.Itprovidessuperiorresiliencetofluorescentandothercommonindoorinterferencesources.Coveragezonesarelimitedbysolidphysicalstructuressuchaswalls;however,contrarytopopularbelief,IRdoesnotneedlineofsightforeffectivecommunication.IRsignalsbounceeffectivelyfromstructuresandwallsfloodtheentireroomincludinglocationsthatarenotindirectlineofsighttotheMonitor.Thebatteryoperationandtheextremelysimplemountingmechanismallowforthequickandlowcostinstallationofthemonitor.AboutCenTrak Gen2IR™TechnologySecondGenerationInfrared(Gen2IR)Monitorscanbepositionedwhereveraccuratelocationdataisneededincludingrooms,hallways,andevenbays.Similartolight,Gen2IRwillnotpassthroughwalls,anditdoesnotsufferfromtraditionalinfraredandultrasoundline‐of‐sightlimitations.Therefore,whenatagreadsaroomnumber,therearenoerrors.Thisiscertainty‐basedRTLS, arequirementfortoday’shealthcareautomationandworkflowapplications.*IT‐313isforusewiththeCenTrak 2.0system.OrderIT‐311forusewiththe1.0system.IT‐313CenTrak MonitorIT‐313MountedtoCeiling
©CenTrak2013.AllRightsReserved.ProprietaryandConfidential.1/03CenTrak,Inc.5CaufieldPlace,Suite102Newtown,PA18940t:215‐860‐2928e:sales@centrak.comwww.centrak.comCenTrak MonitorIT‐313*TechnicalSpecificationsOperationFCCOperatingFrequencyRange 902‐928MHz (Model#IT‐313)*CEOperatingFrequencyRange 868‐870MHz(Model#ITEU‐313)*PowerControl Localon/off,RemoteIRon/offDefaultSetting Factorysetlocationcode markedonMonitorIndicators NoneReachMaximumRoomSize 20’square rooms(withsinglemonitor)Maximum Range Upto60’EnclosureDiameter 6.5in(165.1mm)Height 2.25in(57.15mm)Weight(withoutbatteries) 21 oz (.6kg)Case PCMounting Ceilingtileclip,wall‐mount,desktopoperationMonitor MountingPlate ITA‐352EnvironmentalOperatingTemperature ‐20Cto+70 CStoragetemperature ‐25Cto+80COperatingHumidity SplashresistantoroptionalweatherproofcasePowerExternalPower Externalpoweradaptercapability(optional)contactCenTrakfordetailsBatterytype Pre‐installed LithiumStandard:5+yearstypicalExtendedLifeOption:10+yearstypical*IT‐313isforusewiththeCenTrak 2.0system.OrderIT‐311forusewiththe1.0system.THISDEVICECOMPLIESWITHPART15OFTHEFCCRULESANDINDUSTRYCANADALICENSE‐EXEMPTRSSSTANDARD(S).OPERATIONISSUBJECTTOTHEFOLLOWINGTWOCONDITIONS:(1)THISDEVICEMAYNOTCAUSEHARMFULINTERFERENCE,AND(2)THISDEVICEMUSTACCEPTANYINTERFERENCERECEIVED,INCLUDINGINTERFERENCETHATMAYCAUSEUNDESIREDOPERATION.Modifyingortamperingwiththetransceiver’sorreceiver’sinternalcomponentscancauseamalfunction,invalidatethewarranty,andwillvoidFCCauthorizationtousetheseproducts.ThisproductoritssystemsarecoveredbyoneormoreofthefollowingU.S.patents:5,917,425,7,061,428,7,378,964,7,619,532.L‘utilisationdecedispositifestautoriséeseulementauxconditionssuivantes:(1)ilnedoitpasproduiredebrouillage et (2)l’utilisateurdudispositifdoitétre prêtàacceptertoutbrouillageradioélectriquereçu,mêmesicebrouillageestsusceptibledecompromettrelefonctionnementdudispositif.IT‐313CenTrak MonitorIT‐313MountedtoCeiling
©CenTrak2013.AllRightsReserved.ProprietaryandConfidential.1/03CenTrak,Inc.5CaufieldPlace,Suite102Newtown,PA18940t:215‐860‐2928e:sales@centrak.comwww.centrak.comCenTrak MonitorIT‐313*Accessories*IT‐313isforusewiththeCenTrak 2.0system.OrderIT‐311forusewiththe1.0system.ITA‐361MonitorMetalCeilingAttachment(9/16inch)ITA‐362MonitorMetalCeilingAttachment(15/16inch)ITA‐356DCellLithiumBattery(2)(forillustrationpurposesonly)CeilingAttachmentsPowerITA‐374MonitorWeather‐ProofProtectiveDome(Monitornotincluded)ITA‐351MonitorPowerAdapterITA‐353CeilingTileAttachment(standard)ITA‐363MonitorMetalCeilingAttachment(5/16inch)ITA‐352MonitorMountingPlate(standard)EnclosureIT‐313CenTrak MonitorIT‐313MountedtoCeiling

Navigation menu