Centrak DM34Y LOW FREQUENCY MONITOR ITD-34Y User Manual PowerPoint Presentation

Centrak, Inc. LOW FREQUENCY MONITOR ITD-34Y PowerPoint Presentation

Contents

USERS MANUAL

Download: Centrak DM34Y LOW FREQUENCY MONITOR ITD-34Y User Manual PowerPoint Presentation
Mirror Download [FCC.gov]Centrak DM34Y LOW FREQUENCY MONITOR ITD-34Y User Manual PowerPoint Presentation
Document ID1808940
Application ID9zag7+3nDISqh/lAdEMF5A==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize41.01kB (512641 bits)
Date Submitted2012-10-05 00:00:00
Date Available2012-10-05 00:00:00
Creation Date2012-09-04 11:38:23
Producing SoftwareMicrosoft® Office PowerPoint® 2007
Document Lastmod2012-09-04 11:38:23
Document TitlePowerPoint Presentation
Document CreatorMicrosoft® Office PowerPoint® 2007
Document Author: Adam Peck

Low Frequency Monitor ITK-340
•
•
•
•
•
•
ITK-340 Low Frequency Monitor
900 MHz and Wi-Fi enabled
Quick installation with convenient wall mounting bracket
Can be configured and monitored by central server for
superior control
Battery-operated for plug-an-play installation – no wiring
necessary
2+ years battery life in egress detection mode (less than 1
second update speed)
10+ years battery life in location presence mode (1 minute
updates)
The Low Frequency (LF) Monitor is a signaling unit used with LFenabled tags to segment zones or designate egress points. The LF
Monitors create a detection “sphere”. When a tag enters the LF
Monitor sphere, the tag’s LF sensor is triggered and the tag
immediately reports this event to the CenTrak Location Engine.
The LF Monitors are typically used to segment zones/areas and for
egress detection. The LF Monitors may be strategically placed on the
floor to define zonal areas. When a tag passes the LF Monitor, the
system knows it passed from one zone to another zone. In the same
manner, the LF Monitors may be placed in elevator banks and
stairwells to determine if a tag passed from one floor to another. An
additional use for the LF Monitors involves attaching the devices
under beds and/or chairs to enable bed-/chair-level location accuracy.
ITA-790 Low Frequency
Monitor Mounting Bracket
The battery operation and the extremely simple mounting mechanism,
allow for the quick and low cost installation.
CenTrak, Inc.
5 Caufield Place, Suite 102
Newtown, PA 18940
t: 215-860-2928
e: sales@centrak.com
www.centrak.com
© CenTrak 2012. All Rights Reserved. Proprietary and Confidential. 7/12
Low Frequency Monitor ITK-340
Technical Specifications
Operation
FCC Operating Frequency Range
2.4 - 2.5 GHz
902-928 MHz
125 KHz
Reach
Low range
Up to 4 ft. (battery operated)
Medium range
Up to 8 ft. (battery operated)
Long range
Up to 15 ft. (power adapter)
Enclosure
ITK-340 Low Frequency Monitor
Length
7.38 in (186 mm)
Width
4.75 in (120 mm)
Height
1.9 in (49 mm)
Weight
11.87 oz (.34 kg) without batteries
Mounting
Wall mounting bracket
Monitor Mounting Plate
ITA-790
Environmental
Operating Temperature
0 C to +50 C
Storage temperature
-20 C to +70 C
Operating Humidity
10-90%, non-condensing
Power
ITA-790 Low Frequency
Monitor Mounting Bracket
CenTrak, Inc.
5 Caufield Place, Suite 102
Newtown, PA 18940
t: 215-860-2928
e: sales@centrak.com
www.centrak.com
Battery type
Pre-installed Lithium D Cell (4)
This component complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) The device may not cause harmful
interference, and 2) this device must accept any interference received, including interference that may cases undesired operation. Modifying or
tampering with the transceiver’s or receiver’s internal components can cause a malfunction, invalidate the warranty, and will void FCC authorization to
use these products. This product or its systems are covered by one or more of the following U.S. patents: 5,917,425, 7,061,428, 7,378,964, 7,619,532
L ‘ utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif
doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif.
© CenTrak 2012. All Rights Reserved. Proprietary and Confidential. 7/12

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 2
Language                        : en-US
Tagged PDF                      : Yes
Title                           : PowerPoint Presentation
Author                          : Adam Peck
Create Date                     : 2012:09:04 11:38:23
Modify Date                     : 2012:09:04 11:38:23
Producer                        : Microsoft® Office PowerPoint® 2007
Creator                         : Microsoft® Office PowerPoint® 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ST2-DM34Y

Navigation menu