Centrak IT373GJ Hand Sanitizer i-DIM-GO IT-373GJ User Manual PowerPoint Presentation

Centrak, Inc. Hand Sanitizer i-DIM-GO IT-373GJ PowerPoint Presentation

Users Manual

Download: Centrak IT373GJ Hand Sanitizer i-DIM-GO IT-373GJ User Manual PowerPoint Presentation
Mirror Download [FCC.gov]Centrak IT373GJ Hand Sanitizer i-DIM-GO IT-373GJ User Manual PowerPoint Presentation
Document ID2114748
Application IDPcxOmYeqTi0LIHaLvOltQA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize49.66kB (620780 bits)
Date Submitted2013-11-08 00:00:00
Date Available2013-11-08 00:00:00
Creation Date2013-10-28 15:30:40
Producing SoftwareMicrosoft® Office PowerPoint® 2007
Document Lastmod2013-10-28 15:30:40
Document TitlePowerPoint Presentation
Document CreatorMicrosoft® Office PowerPoint® 2007
Document Author: Adam Peck

IT-373GJ i-DIM-GO
•
•
•
•
IT-373GJ i-DIM-GO
Automatically tracks hand hygiene compliance at the
caregiver level
Collects data on all events at hand washing stations
Designed to integrate with GOJO hand hygiene dispensers
Works in conjunction with CenTrak’s full RTLS and with
CenTrak’s Clinical-Grade Locating Staff Badge.
The Integrated Dispenser Interface Module for GOJO (i-DIM-GO) is a
component of CenTrak’s Clinical-Grade Hand Hygiene Compliance Solution –
the healthcare industry’s only solution designed to automatically monitor
hygiene dispenser usage by caregivers as well as their entry and exit to patient
care areas. It eliminates costly manual monitoring, and proactively alerts
caregivers who enter patient care environments without proper hand hygiene,
to assist in compliance and behavior modification.
IT-373GJ units integrate with GOJO dispensers, and automatically
communicate a specific caregiver’s badge ID from patient care areas along
with hand hygiene events, based upon hospital determined compliance
business rules. The i-DIM-GO communicates each event to the network which
records each caregiver’s compliance performance. All of the recorded data is
stored on CenTrak’s local or hosted server and can be accessed by third party
compliance management and reporting solutions.
The LED indicator on the IT-373GJ flashes a blue confirmation light when the
dispenser is activated and detects a care giver wearing a CenTrak badge is
within range (approximately 4 feet).
The i-DIM-GO captures all hand hygiene events whether or not a caregiver is in
direct line of sight of the module using a combination of technologies. Unlike
other hand hygiene compliance solutions, CenTrak is able to capture 100% of
clinical hand washing events without errors.
IT-373GJ shown integrated
with a GOJO dispenser
CenTrak, Inc.
125 Pheasant Run
Newtown, PA 18940
t: 215-860-2928 e: sales@centrak.com
www.centrak.com
© CenTrak 2013. All Rights Reserved. Proprietary and Confidential.
IT-373GJ i-DIM-GO
Technical Specifications
Operation
FCC Operating Frequency Range
902-928 MHz
Maximum transmission power
1 mW peak
Low Frequency
125 KHz
Indicators
IT-373GJ i-DIM-GO
LED Indicators
Enables integrated blue confirmation LED
light on GOJO Dispenser
Enclosure
Case width
3.1 in (78.7 mm)
Case height
1.85 in (47 mm)
Case depth
0.6 -1.5 in (15 to 38 mm)
Construction
ABS Plastic
Environmental
Operating Temperature
0 C to +50 C
Storage temperature
-30 C to +70 C
Operating Humidity
10% to 90% non-condensing
Power
Battery type
N/A, GOJO Dispenser powered
Activation Sensors
Proximity and/or Motion
Optional configurations
Low Frequency Range
Up to 4 feet
IT-373GJ shown integrated
with a GOJO dispenser
Note: Must use CenTrak disinfection procedure. Other methods may void product warranty.
CenTrak, Inc.
125 Pheasant Run
Newtown, PA 18940
t: 215-860-2928 e: sales@centrak.com
www.centrak.com
This component complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) The device may not cause harmful
interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Modifying or
tampering with the transceiver’s or receiver’s internal components can cause a malfunction, invalidate the warranty, and will void FCC authorization to
use these products. This product or its systems are covered by one or more of the following U.S. patents: 5,917,425, 7,061,428, 7,378,964, 7,619,532.
L ‘ utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif
doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif.
© CenTrak 2013. All Rights Reserved. Proprietary and Confidential.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 2
Language                        : en-US
Tagged PDF                      : Yes
Title                           : PowerPoint Presentation
Author                          : Adam Peck
Create Date                     : 2013:10:28 15:30:40
Modify Date                     : 2013:10:28 15:30:40
Producer                        : Microsoft® Office PowerPoint® 2007
Creator                         : Microsoft® Office PowerPoint® 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ST2-IT373GJ

Navigation menu