Cervis SRF309 Radio Module, DSSS, 10mW, 900MHz User Manual

Cervis Inc. Radio Module, DSSS, 10mW, 900MHz Users Manual

Users Manual

2014 Cervis, Inc.   SRF309 User Manual18 August 2014 U081.0.9 User Manual for SRF309 ™
  Module SRF309    This document is the property of Cervis, Inc. and cannot be copied, modified, e-mailed, or reproduced without the express prior written consent of Cervis, Inc. Cervis, Inc. reserves the right to change this manual or edit, delete, or modify any information without prior notification. Industry Canada Statements RSS-GEN 7.1.2 – Transmitter Antenna / Antenne de L'émetteur Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. This radio transmitter 7955A-SRF309 has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le présent émetteur radio 7955A-SRF309 a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur. Approved Antenna List / Liste Antenne Approuvé Manufacturer Part Number Stock Number  Gain  Impedance Antenna-Factor/Linx Tech  ANT-916-SP  353  +1.49dBipeak  50 Ohm Nearson Or Equivalent S467TR-915S Or Equivalent BB3-06 +2dBipeak 50 Ohm Superpass Or Equivalent SPDAC80 Or equivalent BB3-08 +9dBipeak 50 Ohm  RSS-GEN 7.1.3 – Notice / Délai This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. FCC Statements 15.19 – Two Part Warning This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1)  This device may not cause harmful interference and (2)  This device must accept any interference received, including interference that may cause undesired operation. 15.21 – Unauthorized Modification NOTICE: The manufacturer is not responsible for any unauthorized modifications to this equipment made by the user. Such modifications could void the user’s authority to operate the equipment. 15.27 – Special Accessories This device is supplied with special accessories that include an RF adapter cable and antenna.  These special accessories must be used with the device. It is the responsibility of the user to use the needed special accessories supplied with the equipment. 15.105(b) – Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
User Manual 2014Cervis, Inc.      i  Table of Contents Table of Contents .......................................................................................................................... iList of Figures ............................................................................................................................... iList of Tables ................................................................................................................................. iCervis Inc. Safety Precautions ................................................................................................... 11.0SRF309 Introduction ............................................................................................................ 21.1SRF309 Features ............................................................................................................... 21.2SRF309 Pinouts ................................................................................................................ 32.0SRF309 Installation .............................................................................................................. 93.0SRF309 Tune-up Procedure ................................................................................................ 94.0SRF309 Electrical Characteristics ......................................................................................  94.1Supply Voltage and Current ............................................................................................ 94.2Operating Current ........................................................................................................... 104.3SPI Interface .................................................................................................................... 105.0SRF309 RF Characteristics ............................................................................................... 10 List of Figures Figure 1. SRF309 RF section Front .............................................................................................. 3Figure 2. SRF309 RF section Back ............................................................................................... 3Figure 3. 07440305-9H-12R, component side, shield removed ................................................. 5Figure 4. 07420305-9H-12R, component side .............................................................................. 7Figure 5. 07610305-9H, component side ...................................................................................... 6Figure 6. 14001301-9H, component side ...................................................................................... 8 List of Tables Table 1. 07440205 PCB – connector HDR1 .................................................................................. 3Table 2. 07420205 PCB – connector HDR1 .................................................................................. 7Table 3. 07610204 PCB – connector J10 ...................................................................................... 6Table 4. 14001200 PCB – connector J1 (preliminary) ................................................................. 8
  Module SRF309     U081.0.9-SRF309 User Manual iiNotes and Observations
User Manual  Cervis Inc. Safety Precautions  Read and follow all instructions.   Failure to abide by Safety Precautions may result in equipment failure, loss of authority to operate the equipment, and personal injury.  Use and maintain proper wiring. Follow equipment manufacturer instructions. Improper, loose, and frayed wiring can cause system failure, equipment damage, and intermittent operation.  Changes or modifications made to equipment not expressly approved by the manufacturer will void the warranty.  Owner/operators of the equipment must abide by all applicable Federal, State, and Local laws concerning installation and operation of the equipment. Failure to comply could result in penalties and could void user authority to operate the equipment.  Make sure that the machinery and surrounding area is clear before operating. Do not activate a remote control system until certain that it is safe to do so.  Turn off the module power before attempting any maintenance. This will prevent accidental operation of the controlled machinery.  Do not allow liquid to enter the module enclosure. Do not use high pressure equipment to clean the module.  Operate and store units only within the specified operation and storage temperatures defined in the Specifications of this document.
  Module SRF309     U081.0.9-SRF309 User Manual 21.0 SRF309 Introduction   The SRF309 receive/transmit module (RTM) is based on a single-chip radio frequency (RF) transceiver integrated circuit (RFIC), an Atmel AT86RF212B. The SRF309 RTM is intended to be integrated into Cervis Inc. products, providing a wireless RF connectivity option.   The SRF309 RTM operates in the 915 MHz ISM band, using spread spectrum modulation with a maximum conducted RF transmit power of +8.60dBm at the antenna port.   The RFIC generates RF signals compliant with the Zigbee standard, IEEE 802.15.4-2006. The spread spectrum technique is direct sequence (DSSS), the modulation method is binary phase shift keying (BPSK).   The RFIC has internal control registers that the host application can access via a serial peripheral (SPI) bus. These registers control all aspects of how the RFIC is used, which must be compliant with all applicable rules and regulations.   The SRF309 RTM is interoperable various other Cervis Inc. RTMs that use the same modulation and message data structure. Interoperability with non-Cervis RTMs, while possible, is not supported.   The SRF309 RTM is most commonly applied in half-duplex master/slave systems: the master transmits a message to a slave, the slave transmits a reply to the master. Other operating modes are possible, provided that applicable rules and regulations are not violated.   The SRF309 RTM may be realized in various PCB shapes, some with non-RF circuits applicable to the requirements of particular hot applications. Mechanical variations include:   07440305-9H-12R “Type 1” (tested, pictured)   07610304-9H “Type 2” (not yet tested)   07420305-9H-12R “Type 3” (not yet tested)   14001301 “Type 4” (not yet tested)  1.1 SRF309 Features   FCC Part 15 certified  IC Certified  CE certified  905-925 MHz Operation  2 MHz Selectable Channels   Direct Sequence Spread Spectrum (DSSS)   Binary Phase Shift Keying (BPSK) modulation (tested)  40 kbps Data Rate (tested)  Up to +8.60dBm Output Power (tested)  IEEE 802.15.4-2006 messaging   SPI host interface   Simple power requirements: 3.0-3.3V low noise regulated, 20mA
User Manual 2014Cervis, Inc.      3  Figure 1. SRF309 RF section Front   Figure 2. SRF309 RF section Back  1.2 SRF309 Pinouts Table 1-4 show the pinouts and interface signals on several alternative packaging options for the SRF309 RTM: Table 1. 07440205 PCB (SRF309 Type 1) – connector HDR1 Pin  Name  Signal Details1  SPI_CLK  SPI data clock in  Clock from SPI master 2  GND ground Low impedance ground 3  MISO  SPI data out  Data from SPI slave 4  MOSI  SPI data in  Data from SPI master 5  RF_SLP_TR RFIC control Multipurpose control signal from master 6  /RF_RST  RFIC reset  Low from SPI master
  Module SRF309     U081.0.9-SRF309 User Manual 47  /RF_CS  RFIC chip select  Low from SPI master 8  RF_IRQ  RFIC interrupt output  Input to SPI master 9  RF_PAEN  Enable external PA  High from SPI master 10  RF_HGM/BPA  Enable external LNA or Read BPA jumper Function not used in SRF309 Input to SPI master 11  GND ground Low impedance ground 12  GND ground Low impedance ground 13  DISPLAYCS  Display chip select  Low from SPI master 14  /RFEE_CS (reserved)  EE chip select  Low from SPI master 15  DISPLAYRS  Display register select  From SPI master 16  DISPLAYBLANK  Display on/off  From SPI master 17  reserved reserved reserved 18  reserved reserved reserved 19  DISPLAYRST  Display reset  Low from SPI master 20  reserved reserved reserved 21  LED_6  Indicator  High from SPI master 22  LED_7  Indicator  High from SPI master 23  LED_4  Indicator  High from SPI master 24  LED_5  Indicator  High from SPI master 25  LED_2  Indicator  High from SPI master 26  LED_3  Indicator  High from SPI master 27  LED_0  Indicator  High from SPI master 28  LED_1  Indicator  High from SPI master 29  GND ground Low impedance ground 30  GND ground Low impedance ground 31  +24VDC +3.0-30V Power indicator LED 32  +5VDC +3.0-30V Power indicator LED 33  +3.3VDC  +3.3V  Power indicator LED, RF & logic power. Low noise 50mA max. 34  REVBAT +3.0-30V Power indicator LED  Not required for SRF309        The 07440305-9H-12R PCB assembly includes all circuits and features required for properly implementing the SRF309 RTM. The PCB also provides circuits and mounting for various optional non-RF features of use to a host application, including:   12 indicator LEDs (default installation)   LED/LCD display module (future use)
User Manual 2014Cervis, Inc.      5 Figure 3. 07440305-9H-U-12R, component side, shield, internal label, external antenna connector
  Module SRF309     U081.0.9-SRF309 User Manual 6Table 2. 07610204 PCB (SRF309 Type 2) – connector J10 Pin  Name  Signal Details1  SPI_CLK  SPI data clock in  Clock from SPI master 2  GND ground Low impedance ground 3  MISO  SPI data out  Data from SPI slave 4  MOSI  SPI data in  Data from SPI master 5  RF_SLP_TR RFIC control Multipurpose control signal from master 6  /RF_RST  RFIC reset  Low from SPI master 7  /RF_CS  RFIC chip select  Low from SPI master 8  RF_IRQ  RFIC interrupt output  Input to SPI master 9  RF1_3VD  +3.3V  RF & logic power. Low noise 25mA max. 10  GND ground Low impedance ground 11  RF1_3VA  +3.3V  RF analog  power. Low noise 25mA max. 12  GND ground Low impedance ground 13  RF_PAEN  Enable external PA  High from SPI master 14  RF_HGM/BPA  Enable external LNA or Read BPA jumper Function not used in SRF309 Input to SPI master 15  GND ground Low impedance ground 16  GND ground Low impedance ground 17  GND ground Low impedance ground    The 07610305-9H PCB assembly includes all circuits and features required for properly implementing the SRF309 RTM Type 2. Insert image of 07610304-9H when available Figure 4. 07610304-9H, component side
User Manual 2014Cervis, Inc.      7 Table 32. 07420205 PCB (SRF309 Type 3) – connector HDR1 Pin  Name  Signal Details1  /RFEE_CS (reserved)  EE chip select  Low from SPI master 2  RF_SLP_TR RFIC control Multipurpose control signal from master 3  /RF_RST  RFIC reset  Low from SPI master 4  RF_IRQ  RFIC interrupt output  Input to SPI master 5  /RF_CS  RFIC chip select  Low from SPI master 6  RF_PAEN  Enable external PA  High from SPI master 7  RF_HGM/BPA  Enable external LNA or Read BPA jumper Function not used in SRF309 Input to SPI master 8  SPI_CLK  SPI data clock in  Clock from SPI master 9  MOSI  SPI data in  Data from SPI master 10  MISO  SPI data out  Data from SPI slave 11  GND ground Low impedance ground 12  GND ground Low impedance ground 13  LED_7  Indicator  High from SPI master 14  LED_6  Indicator  High from SPI master 15  LED_5  Indicator  High from SPI master 16  LED_4  Indicator  High from SPI master 17  LED_3  Indicator  High from SPI master 18  LED_2  Indicator  High from SPI master 19  LED_1  Indicator  High from SPI master 20  LED_0  Indicator  High from SPI master 21  GND ground Low impedance ground 22  GND ground Low impedance ground 23  REVBAT +3.0-30V Power indicator LED 24  +5VDC +3.0-30V Power indicator LED 25  +3.3VDC  +3.3V  Power indicator LED, RF & logic power. Low noise 30mA max. 26  +24VDC +3.0-30V Power indicator LED  Not required for SRF309        The 07420305-9H-12R PCB assembly includes all circuits and features required for properly implementing the SRF309 RTM Type 3. The PCB also provides circuits and mounting for various optional non-RF features of use to a host application, including:   12 indicator LEDs (default installation)  insert picture when available Figure 5. 07420305-9H-12R, component side
  Module SRF309     U081.0.9-SRF309 User Manual 8Table 3. 14001200 PCB (SRF309 Type 4) – connections Pin  Name  Signal Details1  SPI_CLK  SPI data clock in  Clock from SPI master 2  GND ground Low impedance ground 3  MISO  SPI data out  Data from SPI slave 4  MOSI  SPI data in  Data from SPI master 5  RF_SLP_TR RFIC control Multipurpose control signal from master 6  /RF_RST  RFIC reset  Low from SPI master 7  /RF_CS  RFIC chip select  Low from SPI master 8  RF_IRQ  RFIC interrupt output  Input to SPI master 9  RF1_3VD  +3.0-3.3V  RF & logic power. Low noise 25mA max. 10  GND ground Low impedance ground 11  RF1_3VA  +3.0-3.3V  RF analog  power. Low noise 25mA max. 12  GND ground Low impedance ground 13  RF_PAEN  Enable external PA  Active high from SPI master 14  RF_HGM/BPA  Enable external LNA or Read BPA jumper Function not used in SRF309 Input to SPI master 15  GND ground Low impedance ground 16  GND ground Low impedance ground 17  GND ground Low impedance ground 18  GND ground Low impedance ground 19  GND ground Low impedance ground 20  RF Port  Antenna connection  50 Ohm RF In/Out port 21  GND ground Low impedance ground    The 14001301 PCB assembly includes all circuits and features required for properly implementing the SRF309 RTM Type 4. Insert image of 14001301 when available Figure 4. 14001301, component side
User Manual 2014Cervis, Inc.      92.0 SRF309 Installation   When integrating an SRF309 RTM into a host application, the user must provide all text in the “FCC Statements” and “Industry Canada Statements” in the host application’s user manual (see Forward Material).  The text must not be modified in any way and presented in a conspicuous manner that the end user can be reasonably expected to access.   When integrating the SRF309 RTM into host application hardware, the user must properly connect all the circuits identified in Table 1 to suitable host application signals. The host application firmware must properly control the RTM to ensure that emitted RF signals comply with all applicable regulatory approvals.   The SRF309 RTM is always provided with an approved type of antenna, either internal fixed or external replaceable. If a fixed internal antenna is provided as part of the RTM, the on-board coaxial cable connectors are not populated. If the module is assembled for use with an external antenna, one of the on-board coaxial cable connector positions will be populated. The choice of the particular type of coaxial connector that is installed will be decided by the designer of the host application. The on-board connector is not accessible to users, so it does not need to be unique. When provided, external replaceable antennas always have a unique connector such as: RP-N, U.FL/IPEX, RP-SMA, RP-BNC or RP-TNC. A suitable coaxial cable jumper with appropriate connectors must be used to connect the SRF309 RTM external antenna port to the external antenna. The details of a particular host application will affect the design of the jumper coax, but the external connector must always be of an acceptable unique type. The coaxial cable used to make the jumper between the RTM and the external antenna mounting position must be suitable for use at 915 MHz and have 50 Ohm impedance. Low loss cable such as RG-316 is suggested, although signal loss will be small if the jumper length is short. External coaxial cables may be used to help mount the replaceable external antenna in a more useful location. Such cable must have appropriate unique connectors and must be made from low loss 50 Ohm coaxial cable. Cables equivalent to LMR-195 are suitable for lengths up to 30 feet. Longer cables must have suitably lower signal loss, typically using larger cable such as LMR240, LMR-300, or larger (or equivalent). At some point, a practical limit is reached where losses in extension cables negate any gains from relocating the antenna. 3.0  SRF309 Tune-up Procedure There is no tune-up procedure. The module contains no adjustable components. Proper RF operation of the module is verified during the manufacturing process using suitable equipment and methods.  4.0  SRF309 Electrical Characteristics 4.1  Supply Voltage and Current The SRF309 RTM (the components under the RF shield) requires the host application to provide a low noise (linear regulator as opposed to a switching regulator) regulated 3.0-3.3 VDC source that can provide 20mA without losing regulation. The RTM does not provide under-voltage, over-voltage, or reverse polarity protection so use caution when applying power. The RTM contains a low noise linear 2.5V regulator (Fig 1.”U2”, top-center) that buffers the analog power to the RFIC RF section. The RFIC has another internal low noise 1.8V regulator (see the data sheet for Atmel AT86RF212B).
  Module SRF309     U081.0.9-SRF309 User Manual 10   All external connection pints designate as signal “GND” should be connected to the host application “GND” circuit so as to maintain as low a resistive and reactive impedance as practical. The PCB hosting the RTM should be fabricated with low impedance copper floods that connect to “GND”.   The SRF309 RTM can safely operate with a supply voltage over the range of 3.0-3.3V with minimal changes in RF performance. Testing was performed at 3.3V, the preferred supply voltage.   Some implementations of the SRF309 module may have additional non-RF functions. The additional circuits may draw current in addition to what the SRF309 RF circuits use. 4.2 Operating Current The SRF309 RTM has four primary operating conditions that draw differing amounts of current from to 3.0-3.3V power source:   Off    RFIC is powered down, minimal load   PLL_ON  RFIC is ready to transmit or receive, ~5mA   RX    RFIC is receiving a message, ~12mA   TX    RFIC is transmitting, ~15-20mA, depending on TX output power   In TX mode the operating current may be less than the maximum if the drive to the external PA is reduced because the full +8.60dBm RF output power is not required. 4.3 SPI Interface   The SPI interface between the RFIC (slave) and the host application (master) microcontroller requires four signals:   SCLK – The serial data clock from the SPI master. Must be less than 8 MHz.   MOSI – Serial data from the SPI master.   MISO – Serial data from the SPI slave.   RF_CS – Chip select from the SPI master.   The SPI controller setting must be established by the host application microcontroller to be compatible with the SPI interface timing specified by the RFIC data sheet. 5.0  SRF309 RF Characteristics 5.1  General RF Information    The RFIC used in the SRF309 RTM implements RF modulation modes and timings in compliance with IEEE 802.15.4-2006. The RFIC implements additional proprietary RF modulation modes. Details may be found in the AT86RF212B RFIC data sheet.   The SRF309 general spread spectrum scheme is DSSS. The modulation type is BPSK. The data rate is 40kbps.  5.2  RF Exposure Considerations     The antennas used with the SRF309 RT module should be positioned to minimize possible RF exposure hazards. Handheld applications of the SRF309 RT module must maintain an antenna separation distance >15mm when used in a normal operating pose. Mobile applications of the
User Manual 2014Cervis, Inc.      11SFR309 RT module must maintain an antenna separation distance >20cm away from areas that are likely to be occupied by human body parts.    These separation requirements must be included in end-user manuals for host applications that include an SRF309 RT module.
  Module SRF309     U081.0.9-SRF309 User Manual 12 Visit our Web site at:  www.cervisinc.com  2014 Cervis, Inc. All rights reserved. Content is subject to change without notice.

Navigation menu