Ventless Fireplace Models: UVDR36C UVDR42C INSTALLER/CONSUMER SAFETY INFORMATION Read and save these instructions. This book contains your installation instructions and should be kept in a safe place. For you to realize all the advantages and use of the reliable service that has been engineered into your CFM Corporation fireplace, you must carefully follow all of the instructions contained in this book regarding installation and operation of the fireplace. These instructions should be read carefully in their entirety before beginning installation of the fireplace. It is suggested that you wear work gloves and safety glasses to protect your hands and eyes when installing your fireplace. NOTE: Authorities having jurisdiction (i.e. building inspectors, fire marshals, etc.) should be consulted before installation to determine the need to obtain a permit. When installing the Blower Kit, it is necessary to bring the power source to the fireplace before walls are enclosed. Refer to Blower Kit instructions. Homeowner’s Installation and 7469 Operating Manual UVDR36/42C cover 2/04 These fireboxes are approved as universal fireboxes and can be paired with any ANSI Z21.11.2 approved vent-free log set. The vent-free log manufacturer’s instructions - including their required dimensional clearances for firebox size, - must be followed. Refer to the manual that is packed with the log set for operating instructions. Not for use in bedroom or bathroom installations. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. 20007469 9/07 Rev. 5 UVDR Series Unvented Gas Fireplaces Table of Contents Hearth Dimensions ........................................................................................................................ 2 Fireplace Dimensions .................................................................................................................. 3 Installation Instructions ............................................................................................................... 4 Locating the Fireplace ........................................................................................................ 4 Gas line .............................................................................................................................. 4 Drafts .................................................................................................................................. 4 Clearances ......................................................................................................................... 4 Installing the Firebox .......................................................................................................... 5 Finishing the Fireplace ....................................................................................................... 7 Hearth Extension ................................................................................................................ 7 Pre-wiring of Junction Box .................................................................................................. 7 Electrical Services .............................................................................................................. 7 BL-4 Blower Installation ...................................................................................................... 8 UVDR36C Installation......................................................................................................... 8 UVDR42C Installation......................................................................................................... 8 Install Optional Outside Air Kit ............................................................................................ 9 Replacement Parts ..................................................................................................................... 11 Accessories ................................................................................................................................ 12 Servicing ..................................................................................................................................... 12 Warranty ...................................................................................................................................... 15 UVDR36C, UVDR42C Certified To ANSI Z 21.91a - 2002 Ventless Fireboxes for use with any ANSI Z21.11.2 Unvented Room Heaters Units: UVDR36C UVDR42C GF1VF2 GF1VF4 B C A FP1531 Front Width Back Width Depth A UVDR36C UVDR42C C FP1531 B hearth dimensions 35” 23¹⁄₈” 16¹⁄₄” djt mm) (413 mm) (889 mm) 9/04 (589 32⁷⁄₈” 18¹⁄₂” 40³⁄₄” (683 mm) (559 mm) (451 mm) Fig. 1 Hearth dimensions. 2 20007469 UVDR Series Unvented Gas Fireplaces Fireplace Dimensions P Rough Opening Depth K L N H P 1/2” Clearance to Combustibles not Required at this Point Rough Opening Height M 1/2” Clearance to Combustibles not Required at this Point Rough Opening Width C F E A J Gas Line Access G B E 6���" D C Fig. 1a UVDR36/42C specifications and framing dimensions. A B C D E F G H J K L M N P 20007469 UVDR36C 36” 21⁷⁄₈” 39” 7” 35” 38¹⁄₄” 9” 21” 8⁵⁄₈” 22” 21” 65” 32¹⁄₂” 46” UVDR42C 42” 21⁷⁄₈” 45” 78984 ADF36/42C 8” SPECS 39” 2/04 42¹⁄₄” 10¹⁄₂” 22” 9³⁄₄” 32” 22” 76¹⁄₄” 38¹⁄₈” 54” 3 UVDR Series Unvented Gas Fireplaces Installation Instructions Locating the Fireplace Figure 2 shows some of the many ways your fireplace may be installed. Consider the traffic pattern in your room and the location of doors and windows. Moving air from ceiling fans, open doors and hot air grilles may cause the flames to soot. If a disturbance is found that effects the flames, it must be eliminated by turning off the ceiling fan, closing the door or closing or moving the hot air register. A corner location may be best where space is limited. Your fireplace weighs no more than some of your fine furniture. If the fireplace is located near a load bearing wall, additional supports to the foundation will not be necessary. HEAVY FACINGS SUCH AS BRICK, STONE, ETC., MAY REQUIRE ADDITIONAL FOUNDATION SUPPORT. ALTHOUGH THIS UNIT MAY BE INSTALLED ON COMBUSTIBLE SURFACES, IT MUST NOT BE INSTALLED ON CARPET OR VINYL. Room Divider Partial Room Projection Full Room Projection Corner Flush T224 Fig. 2 Locating the fireplace. Gas T224 Line place fireplace The gas line must be installed before framing in the fire2/04 place by a licensed gas line installer. Drafts Do not locate the fireplace in high traffic areas or areas exposed to high drafts and winds. Locate the fireplace away from furniture and draperies. Fireplace Clearances The fireplace may be placed directly on a combustible floor, against a combustible wall at marked clearances or on a raised wooden platform. 4 If the fireplace is to be installed on a raised wooden platform, the platform must be a continuous level surface. The fireplace must be secured in place so it cannot shift positions. The nailing flanges on the sides of the firebox make securing it to the framing easy. They were designed to allow the installation of 1/2” wallboard or plywood flush with the face of the fireplace. Only the header (Fig. 1) may rest on the standoffs on top of the firebox. When the fireplace is installed over carpeting, vinyl, tile or any combustible material other than wood flooring, it must be installed on a metal or wood panel extending its full width and depth. Alternatively, the carpeting, vinyl tile, etc., may be removed from beneath the fireplace before installing. COMBUSTIBLE MATERIALS MUST NOT BE INSTALLED OVER OR TOUCH ANY BLACK PAINTED SURFACE. DO NOT BLOCK HEAT CIRCULATING AIR OUTLETS. DOING SO MAY RESULT IN POTENTIAL FIRE HAZARD. Clearances To ensure a safe installation the following instructions must be carefully observed. 1. Sidewall Clearances: Clearances from the side of the fireplace opening to any combustible wall should not be less than 5”. (Fig. 3a) 2. Ceiling Clearances: The ceiling height should not be less than 42” from the top of the fireplace opening. 3. Mantel Clearances: a. If the fireplace has no mantelpiece, then the heat resistant material must extend upwards a distance of at least 9¹⁄₂" from the fireplace opening. A mantel projection must be a minimum of 24” above the top fireplace opening if a canopy is not installed. (Fig. 3b) b. Noncombustible materials used in this installation such as slate, marble, tile, etc. must be at least 1/2" thick. Do not install a combustible material behind sheet metal. Failure to use noncombustible materials above the opening as specified in these instructions may cause damage to the materials used and create a fire hazard. c. A heat reducing canopy is shipped with the fireplace. Use of this canopy is optional in order to reduce mantel heights as shown in Figure 3d. If the canopy is installed, a combustible mantel piece may project 2" from the wall at 6¹⁄₂" above the fireplace opening. A 6" mantel projection at 13" above the fireplace opening and a 10" projection at 22" above the opening. (Fig. 3a and 3d) To install the optional canopy, remove the four (4) screws supplied with a Phillips screwdriver. Two (2) 20007469 UVDR Series Unvented Gas Fireplaces 3a 3c Clearance to Combustible Mantel Projections without Canopy 3d Clearance to Combustible Mantel Projections with 4” Canopy 5" Min. Combustible Perpendicular Wall 3b 10" Clearances without Canopy 6" Noncombustible Material 24" Min. Clearance* from Top of Fireplace Opening (“) 42" 24 22 22 20 20 18 18 16 16 14 14 12 12 10 10 8 8 6 9���" Min. FP604b Fig. 3 Clearances to combustibles. screws are located across the top of the fireplace opening approximately 5” to the right and left from center. Two (2) screws are located 4” down from the top on each side of the fireplace opening. Place the canopy, making sure the 1/4” hex head screws FP604a across the top of clearances the opening align with the clearance holes in the2/04 canopy. Secure with the four (4) previously removed screws. WARNING: The firebox canopy must not be modified or replaced with a canopy that may be provided with the unvented decorative room heater. 4. Floor Clearances: No clearance is required if the appliance is installed per these instructions. Installing the Firebox This list of specific instructions will help you make certain that every installation operation is done correctly. Complete the installation steps in the sequence shown. LOCAL BUILDING CODES SHOULD BE CONSULTED IN ALL CASES AS TO THE PARTICULAR REQUIREMENTS CONCERNING THE INSTALLATION OF FACTORY BUILT FIREPLACES. Select the location for the fireplace by taking into consideration the factors previously outlined in the Locating the Fireplace section of the manual. 20007469 4 6 8 10 Mantel (Combustible) Projections (“) 16" Min. Fireplace Opening 2 2 4 6 8 10 *Combustible Projections above the fireplace must be within the area described by the dashed line. T225 mantel clearance 2/04 T225 Step 1: Framing the Firebox The width of the framed opening must be 39” for 36” models or 45¹⁄₄" for 42" models. (Fig. 4) The entire fireplace can be elevated above the floor to achieve a raised hearth effect. This can be done by adding a small platform to achieve the desired height. NOTE: Refer to Pre-wiring the Junction Box and Electrical Service on Page 7. Step 2: Install the Firebox Install the firebox into the framed opening by setting it directly in front of the opening and sliding it into the proper position. Step 3: Level the Firebox Check the level of the firebox on the top edge of the fireplace face. Shim if necessary. Step 4: Secure the Firebox Four (4) nailing flanges are supplied with the fireplace (found on the fireplace hearth). To level the box and secure it firmly in place, remove the nailing flanges from the hearth and install at the sides of the fireplace as shown in Figure 5. NOTE: The nailing flanges have two (2) sets of holes to allow for adjustment for 1/2” or 5/8” offset of the face of the unit. When installing the nailing flanges, choose the set of holes on the nailing flange that fit with your application. 5 UVDR Series Unvented Gas Fireplaces D The normal gas connection is 1/2” NPT, made at the left side facing the unit. If a right side connection is desired, the connecting pipe must be led at the rear of the fireplace to terminate at the left hand side for connection to the fireplace. 1/2" C Noncombustible Insulation 5" 1/2” Clearance not Required at This Point A Side Refractory 1" Min. Fireplace Outer Wrap Refractory Cement 1/2” Gas Pipe T227 Fig. 6 Gas line installation. B B A Side View Front View 36” Models 42” Models A 39” 45” B T226 C framing dimensions 38¹⁄₄” 21” 2/04 42¹⁄₄” 22” D 22’ 32” T226 Fig. 4 Framing dimensions. Nailing Flanges FP1532 Fig. 5 Secure firebox. Step 5: GasFP1532 Piping and Connection The gas piping must be installed in accordance with Vent free local codes or, in the absence of local codes, in accornailing flanges dance with the National Fuel Gas Code, ANSI Z223.1/ 10/04 NFPA 54, latest edition. 6 Piping should be testedT227 for leaks prior to final wall gas line install installation. Test for leaks using soap and water solution 2/04 after completing the connection. DO NOT USE OPEN FLAME. Step 6: Optional Procedure For Cold Climate Installations The insulation and sealing of the enclosure around the fireplace is very important in cold climates. If the enclosure is insulated and sealed properly, you can avoid future cold air problems. The time taken to install the firebox correctly is well worthwhile. The following steps are to stop potential cold air problems. Insulation of the Fireplace Enclosure When in a chase or an outside wall, the fireplace enclosure should be insulated like any other wall of your home. Insulation should be installed on the outside wall(s) and the wall above the fireplace. Insulate to Seal Under the Fireplace Insulating under the fireplace is beneficial for installations on a concrete slab. The fireplace should be placed on insulating board. It is important that a hard, rigid surface be maintained, so do not use fiberglass insulation for this purpose. CAUTION: WHEN INSTALLING A FIREPLACE IN AN INSULATED ENCLOSURE, BE SURE TO MAINTAIN ALL MARKED AIR SPACES. Seal Seams Seal the seams of the fireplace where the outer wall meets the bottom pan and the front face. Also seal between the fireplace and finishing materials. Use high temperature caulk. Refer to Figure 7 for details of sealing spaces between the fireplace and finishing materials. Note the small amount of insulation installed across the top of the fireplace and down the sides as a backing for the caulk. 20007469 UVDR Series Unvented Gas Fireplaces Hearth Extension Finishing Material A hearth extension may be used but is not required for these fireboxes. Stud Noncombustible Material Insulation Caulking or Sealant A raised hearth extension may be used as shown in Figure 8. Hearth Extension Standoff Hearth Brick Seal with Noncombustible Material Side View 1/2" Noncombustible Insulation Finishing Material Top View Caulking or Sealant FP568 Fig. 7 Sealing spaces between fireplace and finishing materials. Finishing the Fireplace There are a wide variety of finishing materials availFP568 able for your fireplace from formal wall treatments with UVBR/CN marble and mantels to7/01 rustic wood paneling, stone or brick. IT IS IMPORTANT THAT THE BLACK FACE OF THE FIREPLACE NOT BE COVERED WITH ANY TYPE OF COMBUSTIBLE MATERIAL. Noncombustible facing materials such as marble, brick or ceramic tile may overlap the black face of the fireplace up to the opening on either side of the fireplace. Seal all joints between the black fireplace face and the wall covering with a heat-resistant material such as rock wool insulation or mortar. Be sure to use high temperature adhesive or mortar when anchoring brick, stone or tile to the face of the fireplace. Check to see whether man-made brick and stone are made of noncombustible materials before using them on the face of the fireplace. Some of these products contain combustible materials. Combustible wall coverings such as paneling or wallboard may not overlap the black face of the fireplace. The space between the wall covering and the fireplace should be sealed with a heat-resistant material such as rock wool insulation or mortar. NOTE: An “L” shaped steel lintel must be installed across the top of the firebox opening where facing materials such as brick or stone are used on the face of the firebox. It acts as a support/firestop. It should be attached to the face of the fireplace with screws and sealed to the fireplace with a heat-resistant sealer. WARNING: The firebox screens must be in place before operating the fireplace. WARNING: These vent free fireplaces are not to be used with glass doors. 20007469 Combustibles Allowed (no carpet or vinyl) Surround Combustible Plateform T238 Fig. 8 A raised hearth extension. T238 Pre-Wiring of Junction Box Hearth Extension 2/26/04 djt Wiring should be connected at the junction box located on the right side of the firebox prior to the installation of the blower kit. A standard wall box should be used to contain the SCVS - Variable Speed Control Kit. Electrical Services If an electrical supply of 120V is being roughed in to the fireplace junction box to provide for future installation of optional blower kit, the wiring should be connected to the junction box located on the right side of the firebox. NOTE: All electric connections are to be made in accordance with CSA Standard C22.1-Canadian Electrical Code part 1 or with the National Electrical Code, ANSI/ NFPA 70 (latest edition) and/or in accordance with local codes. CAUTION: Should this blower require servicing, the power supply must be disconnected. 120 Volt Speed Control Switch M Black White G Wall Electrical Box Firebox Accessory Junction Box T229 Fig. 9 Blower wiring diagram. T229 Blower wiring diagram 2/11/04 djt 7 UVDR Series Unvented Gas Fireplaces Blower Installation BEFORE YOU BEGIN...A FEW BASIC RULES 1. Check to ensure that electrical service has been provided to the junction box located in the bottom chamber of the firebox. 2. Check local building codes before installation of the firebox and the blower kit. 3. All wiring must be installed and/or inspected as necessary to comply with the local authority having jurisdiction. 4. The circuit breaker controlling the power supply to the pre-wired junction box in the appliance must be in the “OFF” position before beginning installation of the blower. 5. The appliance, when installed, must be electrically grounded in accordance with local codes or - in the absence of local codes - with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1. Step 2: The SCVS - Variable Speed Control Kit (or standard wall switch) should be installed before the blower assembly installation. Please refer to instructions found in the SCVS Kit. Step 3: Remove the metal hearth cover and the bottom two right brick panels from the fireplace and carefully place them to the side to prevent damage. Step 4: Locate the blower access cutout found at the rear of the hearth pan. Next, remove tape backing from tape on blower housing. Center the blower assembly in the access cutout area with the blower outlet duct pointing upward, then press firmly to attach foam tape to the back and bottom of the fireplace. (Fig. 10) Step 5: Locate the junction box cutout found on the right side of the hearth pan. Route the powercord under the hearth pan and plug it into the receptacle outlet found in the junction box. (Fig. 11) Step 6: Turn power back on and test blower operation. Step 7: Replace the metal hearth cover and the bottom two center panels in the fireplace. Read all the installation instructions for the applicable appliance before beginning the installation of the blower. UVDR36C Blower Installation Step 1: Carefully unpack the blower assembly and familiarize yourself with the parts. Care should be taken not to damage the fan blades or housing. Step 2: The SCVS - Variable Speed Control Kit (or standard wall switch) should be installed before the blower assembly installation. Please refer to instructions found in the SCVS Kit. Step 3: Remove the bottom brick from the fireplace and carefully place it to the side to prevent damage. Use a flat blade screwdriver to gently lift up the front edge of the brick, then pull forward to remove. Step 4: Locate the blower access cutout found at the rear of the hearth pan. Next, remove tape backing from tape on blower housing. Center the blower assembly in the access cutout area with the blower outlet duct pointing upward, then press firmly to attach foam tape to the back and bottom of the fireplace. (Fig. 10) Step 5: Locate the junction box cutout found on the right side of the hearth pan. Route the powercord under the hearth pan and plug it into the receptacle outlet found in the junction box. (Fig. 11) Step 6: Turn power back on and test blower operation. Step 7: Replace the bottom brick in the fireplace. Blower Access Cutout inHearth Pan Back Firebrick NOTE: Hearth brick and/or hearth cover is removed as shown to gain access for blower and junction box installation. T230 Fig. 10 Blower access. T230 blower access Receptacle Outlet in Juc2/04 tion Box UVDR42C Blower Installation Step 1: Carefully unpack the blower assembly and familiarize yourself with the parts. Care should be taken not to damage the fan blades or housing. 8 Junction Box Cutout in Hearth Pan of Firebox T231 Fig. 11 Route powercord under the hearth pan and plug into the receptacle outlet. T231 junctin box cutout 2/04 20007469 UVDR Series Unvented Gas Fireplaces Install Optional Outside Air Kit The AKU3 Outside Air Kit can be installed to bring combustion air to the heated room air. The air that is drawn into the heated room air from outside the home or unheated area helps relieve the pressure in the home. The duct termination should be located so it is exposed to an out-of-doors opening at least 100 square inches. If the duct termination must be located in a crawl space or basement, be sure the termination area has 100 square inches of ventilation opening to outside air. The duct termination must be located so it does not compete for air flow with exhaust fans, gas vent hoods or other air consuming devices or appliances. It must not be obstructed by rafters, insulation materials or other obstructions. The less restrictive the air supply, the better the outside air kits will perform. should be caulked around its perimeter to assure a tight seal. The rain cap opening should be positioned downward. (Fig. 15) The Outside Air Kit is now installed and ready for use. Soffit Termination Attic Duct Termination Ceiling 40’ Max. Duct Run Duct It is good practice to protect your hands and eyes during installation by wearing work gloves and safety glasses. CAUTION: Do not install termination into a garage or other area that could contain flammable liquids or fumes, or into an attic space. Installation Instructions Determine the location of the fireplace as described in the fireplace installation manual. Then plan location of the duct termination and the route of the duct run between the fireplace and the duct termination. Duct run must be limited to a maximum distance of 40’ (12.2m) from the fireplace pipe collar to duct termination. This will provide the least restriction to air flow. No more than four (4) 90° elbows can be used. Duct run may be horizontal, vertical, inclined or any combination of these. (Fig. 12) You are now ready to install the Outside Air Kit. 1. Remove the screws retaining the outside air coverplate, if provided. (Located on the left side of front open units, on backside of multisided units.) Discard coverplate. (Fig. 13) 2. Secure the inlet collar assembly to the outer casing with four screws (not provided). (Fig. 14) 3. Slide the duct over the collar and attach the duct to the collar using the plastic tie straps or three (3) screws (screws not provided). Continue attaching the ducting together using three (3) screws at each joint until you have installed sufficient duct to arrive at your duct termination locations. 4. At the termination end, install the duct termination. This should be installed from the outside of the home. Cut a hole in the desired location approximately 4¹⁄₂” (114mm) in diameter, caulk around the hole, and slide the termination through the opening from outside the home. The termination/rain cap 20007469 Exterior Wall Termination Exterior Wall 40’ Max. Duct Run Rain Cap Duct Termination Duct FP1060 Fig. 12 Typical outside air installations. Cover Plate FP1060 AKMST installation 7/6/00 djt KT143 Fig. 13 Remove outside air cover plate and discard, retain screws. KT143 AKU cover plate 9/5/00 djt 9 UVDR Series Unvented Gas Fireplaces Operating Precautions and Instructions Operation is automatic. A slight negative pressure inside the house will open the barometric flapper valve. Periodically inspect the duct termination for any blockage. Correct if necessary. KT145 Fig. 14 Secure the inlet collar assembly. Caulking KT145 Duct TerAKU reinstall mination cover plate 9/6/00 djt Rain Cap Wall FP1061 Fig. 15 Caulk and install duct termination/rain cap in place. FP1061 AKMST rain cap 7/6/00 djt 10 20007469 UVDR Series Unvented Gas Fireplaces 7 5 6 2 1 3 8 4 9 12 10 13 11 14 7469 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. UVDR36/42C Series Unvented Fireplaces 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 7469 Description UVDR36/42C parts Firescreen Rod (2 per fireplace) 8/04 Firescreeen w/Rings (2 per fireplace) Screen Retainer (4 per fireplace) Black Canopy Back Brick Right Side Brick Left Side Brick Side Brick (2 per fireplace) Bottom Brick Bottom Left Brick Bottom Middle Right/Left Brick Bottom Right Brick Cover, Hearth Nailing Flange - Bag of 4 w/Screws 20007469 UVDR36C 68403 66146 62222 68779 73535 73498 75752 -73500 ----2253160 UVDR42C 65864 62197 62222 69554 73395 --73394 -79013 79014 79015 78988 2253160 11 UVDR Series Unvented Gas Fireplaces Accessories Decorative Surrounds Blower Kit (Junction box is provided with fireplace) Variable Speed Control Heat Reducing Canopy Brick Canopy Outside Air Kit Contact CFM Corporation for questions concerning prices and policies covering replacement parts. Parts may be ordered through your Majestic Fireplaces distributor or dealer. You will need the correct name, part number and model number of the appliance when ordering replacement parts. SPB36 SPB42 BL-4 or FK12 SCVS UC36PB (UVDR36C) Polished Brass UC42PB (UVDR42C) Polished Brass BC36L (UVDR36C) BC42L (UVDR42C) AKU3 Servicing Repair and replacement work should only be done by a qualified service person. Always shut off the gas supply and make sure the appliance is cool before beginning any service operation. Always check for gas leaks after servicing. Should you need additional information beyond what your dealer can furnish, contact: CFM Corporation 410 Admiral Blvd. Mississauga, Ontario Canada L5T 2N6 12 20007469 UVDR Series Unvented Gas Fireplaces 20007469 13 UVDR Series Unvented Gas Fireplaces 14 20007469 UVDR Series Unvented Gas Fireplaces LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations. EXTENDED LIFETIME WARRANTY The heat exchanger, where applicable, and combustion chamber of every Vermont Castings or Majestic gas product is warranted for life against through wall perforation. All appliances equipped with an Insta-Flame Ceramic Burner have limited lifetime coverage on the ceramic burner plaque. Warrantees are made to the original owner subject to proof of purchase and the conditions and limitations listed on this Warranty Document • • • • COMPONENT WARRANTY CAST IRON: All external and internal cast iron parts are warranted for a period of three years. Note: On porcelain enamel finished external parts and accessories The Company offers no Warranty on chipping of enamel surfaces. Inspect all product prior to accepting it for any damage to the enamel. The salt air environment of coastal areas or a high humidity environment can be corrosive to the porcelain enamel finish. These conditions can cause rusting of the cast iron beneath the porcelain enamel finish, which will cause the finish to flake off. Dye lot variations with replacement parts and/or accessories can occur and are not covered by warranty. GLASS DOORS: Glass doors are covered for a period of one year. Glass doors are not warranted for breakage due to misuse or accident. Glass doors are not covered for discoloration or burned in stains due to environmental issues, or improper cleaning and maintenance. BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar mix and masonry cleaners may corrode the brass finish. The Company will not be responsible for, nor will it warrant any brass parts which are damaged by external chemicals or down draft conditions. GAS VALVES: Gas valves are covered for a period of one year • • • • • • ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and mechanical components of the burner assembly are covered for one year. All steel tube burners are warranted for one year. ACCESSORIES: Unless otherwise noted all components and CFM Corporation company supplied accessories are covered for a period of one year. CONDITIONS AND LIMITATIONS • • • • This new Vermont Castings or Majestic product must be installed by a competent, authorized, service contractor. A licensed technician, as prescribed by the local jurisdiction must perform any installation/service work. It must be installed and operated at all times in accordance with the Installation and Operating instructions furnished with the product. Any alteration, willful abuse, accident, or misuse of the product shall nullify this warranty. This warranty is non-transferable, and is made to the original owner, provided that the purchase was made through an authorized supplier of the Company. The customer must pay for any Authorized Dealer in-home travel fees or service charges for in-home repair work. It is the dealers option whether the repair work will be done in the customer’s home or in the dealer’s shop. If upon inspection, the damage is found to be the fault of the manufacturer, repairs will be authorized at no charge to the customer parts and/or labor. 20007469 • Any part and/or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty, whichever is longest. This warranty is limited to the repair of or replacement of part(s) found to be defective in material or workmanship, provided that such part(s) have been subjected to normal conditions of use and service, after said defect is confirmed by the Company’s inspection. The company may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of the defective part(s) Any installation, labor, construction, transportation, or other related costs/expenses arising from defective part(s), repair, replacement, or otherwise of same, will not be covered by this warranty, nor shall the Company assume responsibility for same. Further, the Company will not be responsible for any incidental, indirect, or consequential damages except as provided by law. SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. All other warranties-expressed or implied- with respect to the product, its components and accessories, or any obligations/liabilities on the part of the Company are hereby expressly excluded. The Company neither assumes, nor authorizes any third party to assume on its behalf, any other liabilities with respect to the sale of this Vermont Castings or Majestic product The warranties as outlined within this document do not apply to chimney components or other non CFM Corporation accessories used in conjunction with the installation of this product.. Damage to the unit while in transit is not covered by this warranty but is subject to claim against the common carrier. Contact the dealer from whom you purchased your fireplace/stove (do not operate the appliance as this might negate the ability to process the claim with the carrier). The Company will not be responsible for: a) Down drafts or spillage caused by environmental conditions such as near-by trees, buildings, roof tops, hills, or mountains. b) Inadequate ventilation or negative air pressure caused by mechanical systems such as furnaces, fans, clothes dryers, etc. This warranty is void if: a) The fireplace has been operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals. b) The fireplace has been subjected to prolonged periods of dampness or condensation c) Any damages to the fireplace, combustion chamber, heat exchanger or other components due to water, or weather damage, which is the result of but not limited to, improper chimney/venting installation. d) Any alteration, willful abuse, accident, or misuse of the product has occurred. IF WARRANTY SERVICE IS NEEDED… 1) Contact your supplier. Make sure you have your warranty, your sales receipt, and the model/serial number of your CFM Corporation product. 2) DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF. 15 CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www.cfmcorp.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 16 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:d91965e0-5cae-11dc-a120-0003934a9da6 Create Date : 2007:09:06 15:24:13Z Metadata Date : 2007:09:06 15:24:55-04:00 Modify Date : 2007:09:06 15:24:55-04:00 Creator Tool : Adobe InDesign CS (3.0.1) Rendition Class : proof:pdf Derived From Instance ID : 1b4ed454-5e18-11dc-9c8e-84eea4362c13 Derived From Document ID : adobe:docid:indd:d918d37c-c805-11db-88f4-b2cc26a4b5d6 Document ID : adobe:docid:indd:8d9c6574-5e1f-11dc-9c8e-84eea4362c13 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Reference Instance ID : uuid:0afe2260-15a1-11db-b3bd-0003934a9da6, uuid:091978a1-15a1-11db-b3bd-0003934a9da6, uuid:6c069d9e-c2fb-11d9-967c-0003934a9da6, uuid:9fa4021e-c2f9-11d9-967c-0003934a9da6, uuid:5ed674e6-c2fb-11d9-967c-0003934a9da6, uuid:82a793a2-9b3c-11db-bb81-0003934a9da6, uuid:3e5540f7-894e-11db-ad12-0003934a9da6, uuid:833ea67a-9b3c-11db-bb81-0003934a9da6, uuid:82fa758a-9b3c-11db-bb81-0003934a9da6, uuid:0a3e95f9-15a1-11db-b3bd-0003934a9da6 Manifest Reference Document ID : uuid:08044d90-8755-11da-a305-0003934a9da6, uuid:b7bca84c-c864-11d9-8162-0003934a9da6, uuid:6c068dd0-c2fb-11d9-967c-0003934a9da6, uuid:9fa3f034-c2f9-11d9-967c-0003934a9da6, uuid:5ed667d4-c2fb-11d9-967c-0003934a9da6, uuid:a766aa44-c192-11d9-b371-0003934a9da6, uuid:b45fd3a1-c192-11d9-b371-0003934a9da6, uuid:bd1ab315-c192-11d9-b371-0003934a9da6, uuid:c5bb620c-c192-11d9-b371-0003934a9da6, uuid:0a3e8a15-15a1-11db-b3bd-0003934a9da6 Format : application/pdf Title : 2-7469 UVDR36_42C.indd Trapped : False Creator : Adobe InDesign CS (3.0.1) Producer : Adobe PDF Library 6.0EXIF Metadata provided by EXIF.tools