Chamberlain Group The 1216 Garage Door Opener User Manual instructions
Chamberlain Group Inc, The Garage Door Opener instructions
instructions
Lift-Musten s proh ted, except for ctta transmitter battery HERE ARE No OTHER USER SERVIOEABLE PARTS. Features For use with any SECURITY-i- compatible garage door opener receiver. Personalized Password: Up to 10,000 possible combinations. Password can be easily changed if desired. Temporary password: Can be added tor Visitors or service persons. This temporary password can be limited to a programmable number ol hours or a programmable number of entries. Rolling Code: While your password remains constant until you change it. the code between the Keyless Entry and the receiver changes with each use, randomly accessing over 100 billion new codes. Operation: Opener activates when 4-digit password and Enter button is pressed, It wrong numbers are accidentally pressed, correction can be made immediately. The Enter button will transmit only the last four digits. The Keypad will blink tor 15 seconds after the password is transmitted, During that time the Enter button can be used to stop or reverse the door travel. Setting the Personal Entry Password We recommend that you program your personal password now, before you install the Keyless Entry. Then you can test the reception at the mounting location before you proceed further. 1, Choose a 4-digit personal entry password using the numbers from 0 to 9 (a number can be used more than once. for example, 4,0, 4,1). 2. Press the four buttons for the password, then press and holdthe Enter button. The indicator light on the door opener panel will blink. 3. Press and release the “Smart" (learn) button on the door opener panel. After the opener lights blink, release the Enter button. Test by pressing the the password, then press Enter. The door should begin to move. SECURITY-I- Garage Door Opener 'Smarl' (learn) Button indicator ugnl You may also program the Keyless Entry from a multifunction door control, as follows: 1. With the door closed, enter the tour digit password desired. then press and hold Enter. 2. Press and hold the light button on the door control. 3. Press and hold the door control push bar. 4. After the opener lights blink, release all buttons. Model 976LM, 976LMC Security-l- Wireless Keyless Entry Children operating or playing with a garage door opener can iniure themselves or others. The garage door could close and cause serious injury or death. Do not allow children to operate the wall push button(s) or remote control(s). A moving garage door could lniure or kill someone under It. Activate the opener only when you can see the door clearly, It is free of obstructions, and is properly adiusted. Installation Choose a convenient location for installation. ./ It should be at eye level. reachable by the shortest person who will use it, and within sight of the door. For a one-piece door, use the optional location shown in the illustration (on the edge of the door jamb) to avoid injury as the door swings up and out. Test the reception of the Keyless Entry by operating your opener from the selected location. Change the location if necessary. Remove the battery compartment mowingmle cover to access the bottom mounting hole: - insert a small phillips screw driver ”my Q 1 into the small hole at the bottom of may " " the cover and gently pull outward to Cover loosen. V 0 Slide the cover down to remove. Center the keypad at eye level against the selected location. Mark 4-1/4" up the centerline from the bottom and drill a 1/8" pilot hole. Install top mounting screw, allowing 1/ “ to protrude above surface. Position keypad on screw head and adjust for snug fit. With cover open so bottom mounting hole is visible, use a punch to mark hole. Remove keypad and drill 1/8" pilot hole. Replace keypad and complete installation with bottom screw, using care to avoid cracking plastic housing. Do not overtighten. To replace the battery cover. insert the lip at the top and snap in place. Typical Sectional Door installation Exterior Front Wall l-Plece or Secltoflal Door Door Jamb Edge (Optional Location for l»Piece Door) Door Jarnb Face SECTIONAL DOOR oNLv KEVPAD MUST BE INSTALLED WiTHlN SIGHT or THE DOOR Bottom Side two contains instructions for changing the personal entry password and setting a temporary password. Changing the Personal Entry Password Press the tour buttons lor the present password, then press and hold the # button. The opener light will blink twice. Release the it button. Press the new 4-digit password you have chosen, then press Enter. The opener light will blink once when the password has been learned, Test by pressing the new password, then press Enter. The door should move. Setting a Temporary Password In addition to the personal entry password which works at all times, a 4-digit temporary password can be added for the convenience of visitors or service persons. This allows authorized persons a way to gain temporary access. After a programmed number of hours or number ol accesses, this temporary entry password expires and will no longer open the door. The temporary password can be used to close the door even after it has expired. To set a temporary entry password: 1. Press the four buttons for your personal entry password (not the last temporary password), then press and hold the =l= button. The opener light will blink three times. Release the button. 2. Press the temporary 4-digit entry password you have chosen, then press Enter. The opener light will blink four times. 3. To set the number of hours this temporary password will work, press the number of hours (up to 255), then press *. OR 3. To set the number of times this temporary password will work. press the number of times (up to 255), then press #. The opener light will blink once when the temporary password has been learned, Test by pressing the tour buttons for the temporary password, then press Enter. The door should move. If the temporary password was set to a certain number of openings. remember that the test has used up one opening. To clear the temporary password, repeat steps 13, setting the number ot hours or times to 0 in Step 3. Battery The 9 volt battery should produce power for at least one year. Replace when keypad illumination becomes dim. FOR SERVICE DIAL OUR TOLL FREE NUMBER: 1-800-528-2817 IN CANADA, DIAL 1-800-654-4736 ©1997 The Chamberlain Group, Inc. 1 t 4A2232 All nghts Reserved Printed in Mexlcu
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Modify Date : 2000:02:04 15:48:13 Creator : Photoshop PDF Plug-in 1.0 Producer : Photoshop PDF Plug-in 1.0 Create Date : 2000:02:04 15:47:16 Page Count : 2EXIF Metadata provided by EXIF.tools