Chamberlain Group The 1591 Remote Control Transmitter User Manual Exhibit D Users Manual per 2 1033 b3

Chamberlain Group Inc, The Remote Control Transmitter Exhibit D Users Manual per 2 1033 b3

Exhibit D Users Manual per 2 1033 b3

Download: Chamberlain Group The 1591 Remote Control Transmitter User Manual Exhibit D Users Manual per 2 1033 b3
Mirror Download [FCC.gov]Chamberlain Group The 1591 Remote Control Transmitter User Manual Exhibit D Users Manual per 2 1033 b3
Document ID170558
Application IDoQmr0bHN4LKaDgi+XrS+nA==
Document DescriptionExhibit D Users Manual per 2 1033 b3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize32.86kB (410729 bits)
Date Submitted2001-09-20 00:00:00
Date Available2001-09-20 00:00:00
Creation Date2001-09-12 11:13:46
Producing SoftwareAcrobat 4.0 Import Plug-in for Windows
Document Lastmod2001-09-12 11:14:44
Document TitleExhibit D Users Manual per 2 1033 b3
Document CreatorAcrobat 4.0 Import Plug-in for Windows

fyfl/ML 14/5 TIUéflaA/S
Lift-Muster "
it: lll'l‘Y-F
To comply with rcciic rules, adiustment or moaiircaticn oi receiver mid/Dr
transmiller IS prohibited, except for changing the code selling and replacing the
transmitter oallery THERE ARE No OTHER USER SERVICEABLE PARlS.
Features
For use With any SECURlTY+
compatible garage door opener
receiver,
Personalized Password: Up to
10,000 possible combinations Password
can be easily changed it desired
Temporary password: Can be added tor visitors
or service persons. This temporary password can be
limited to a programmable number ol hours or a
programmable number oi entries,
Rolling Code: While your password remains constant until
you change it, the code between the Keyless Entry and the
receiver changes with each use, randomly accessing over
tot) billion new codes.
Operation: Opener activates when 4-dlgit password and
Enter button is pressed.
ll wrong numbers are accidentally pressed, correction can be
made immediately. The Entor button wtll transmit only the last
four digits.
The Keypad will blink tor 15 seconds alter the password is
transmitted During that time the Enter button can be used to
stop or reverse the door travel.
Setting the Personal Entry Password
We recommend that you program your personal
password now, before you install the Keyless Entry.
Then you can test the reception at the mounting
location before you proceed further.
1. Choose a 4-digit personal entry password using the
numbers from 0 to 9 (a number can be used more than
once, for example, 4,0, 4,1).
2. Press the four buttons for the
password, then press and
holdthe Enter button. The
indicator light on the door
opener panel will blink.
3. Press and release the “Sman‘
(learn) button on the door
opener panel. After the
opener lights blink, release
the Enter button.
Test by pressmg the the password, then press Enter. The
door should begin to move.
SECURITY-I-
Garage Door Opener
'Smarl' (learn)
Blllton
indicator ugm
You may also program the Keyless Entry from a
multifunction door control, as follows:
1. With the door closed, enter the tour digit password
desrred, then press and hold Enter.
2. Press and hold the light button on the door control.
3. Press and hold the door control push bar.
4. Alter the opener lights blink, release all buttons.
Model 7— 3/51- M Security-I-
3 [5M/1z Wireless Keyless Entry
Children operating or playing th a garage door
opener can injure themselves or others. The
garage door could close and cause serious injury
or death. Do not allow children to operate the wall
push hutton(s) or remote control(s).
A moving garage door could injure or kill someone
under it. Activate the opener only when you can see
the door clearly, it is tree of obstructions, and is
properly adjusted.
Installation
Choose a convenient
location for installation.
It should be at eye
level, reachable by the
shortest person who
will use it, and within M . . . ;1/'//goorianc Edge
Sight of the door. ~\ 1 if/ l'ovr‘l‘lfigzmoggofigl
For a onevpicce door, ‘
use the optional
location shown in the
illustration (on the edge ‘
of the door ramp) to avoid injury as the door
swings up and out.
Test the reception of the Keyless
Entry by operating your opener
from the selected location.
Change the location if necessary.
Remove the battery compartment
cover to access the bottom
mounting hole:
0 Insert a small phillips screw driver
into the small hole at the bottom of
the cover and gently pull outward to
loosen,
. Slide the cover down to remove.
Typical
KevDsd////\r / /
Se |
~77t ig/ .°.‘:::i.i:,:°'
V‘x/f/ EkleriurFiontWall
., //— Hiram
Sectional Door
Dooriaiiiti Face
srCTiONAi noon ONLV
KEVF'AD MUST BE INSTALLED
WlTHlN sici W or THE boon
Bottom
mounting hole 7
Baltery
Driver
Center the keypad at eye level against the selected
location. Mark 4-1/ " up the centerline from the bottom and
drill a 1/8" pilot hole. Install top mounting screw, allowing
1/8” to protrude above surface. Posilion keypad on scrcw
head and adjust for snug fit.
With cover open so bottom mounting hole is Visible, use a
punch to mark hole. Remove keypad and drill t/ “ pilot
hole, Replace keypad and complete installation with
bottom screw, using care to avoid cracking plastic housing
Do not overtighten.
To replace the battery cover, insert the lip at the top and
snap in place.
Side two contains instructions for changing the personal
entry password and setting a temporary password.
Changing the Personal Entry Password
Press the tour buttons tor the present password. then
press and hold the t‘t button.
The opener light will blink twice. Release the # button.
Press the new 4-digit password you have chosen, then
press Enter.
The opener light will blink once when the password has
been learned.
Test by pressing the new password, then press Enter.
The door should move.
Setting a Temporary Password
In addition to the personal entry password which works at
all times, a 4~digit temporary password can be added lor
the convenience of visitors or service persons. ThlS
allows authorized persons a way to garn temporaly
access. After a programmed number of hours or number
of accesses, this temporary entry password expires and
will no longeropan the door. The temporary password
can be used to close the door even after it has expired.
To set a temporaw entry password.
1. Press the tour buttons for your personal entry password
(not the last temporary password), then press and hold
the >l< button.
The opener light will blink three times. Release the
button.
2. Press the temporary 4~digit entry password you have
chosen, then press Enter.
The opener light will blink four times.
3. To set the number of hours this temporary password
Will work, press the number of hours (up to 255), then
press >l=.
OR
3. To set the number of times this temporary password
will work, press the number of times (up to 255), then
press tt.
The opener light Wlll blink once when the temporary
password has been learned.
Test by pressing the tour buttons for the temporary
password, then press Enter. The door should move. It the
temporary password was set to a certain number of
openings, remember that the test has used up one
opening.
To clear the temporary password. repeat steps 1-3,
setting the number of hours or times to 0 ln Step 3.
7x
Battery
The 9 volt battery should produce power lor at least one
year. Replace when keypad illumination becomes dim.
FOR SERVICE DIAL OUR TOLL FREE NUMBER: 1~BOD~528~2817
IN CANADA, DIAL 1-600-654-4736
©1997 The Chamberlain Group, Inc.
114A2232
All Rights Reserved
Printed in Mexlco

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Modify Date                     : 2001:09:12 11:14:44-05:00
Create Date                     : 2001:09:12 11:13:46-05:00
Creator                         : Acrobat 4.0 Import Plug-in for Windows
Producer                        : Acrobat 4.0 Import Plug-in for Windows
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: HBW1591

Navigation menu