Chamberlain Group The 190A1808-1 Keypad Access Control User Manual 01 37534 REVIEW indd
Chamberlain Group Inc, The Keypad Access Control 01 37534 REVIEW indd
User Manual
Wireless Commercial Keypad Models KPW5 and KPW250 OVERVIEW The Wireless Commercial Keypad comes with one 9V Lithium battery, instructions, and two keys. A wireless signal is transmitted when a valid 4-digit PIN and the # key is pressed. A long tone will sound. The keypad backlight will illuminate for 15 seconds when any key is pressed. If an invalid PIN or partial PIN is accidentally entered, an error tone will sound. The Wireless Commercial Keypad is compatible with the brands of commercial door and gate operators listed in the table below. MODEL FREQUENCY AND ENCRYPTION PIN CAPACITY KPW5 LiftMaster Security+ 2.0™ Default Tri-band 390 MHz, 315 MHz, and 310 MHz LiftMaster Security+ 2.0™ Default Tri-band 390 MHz, 315 MHz, and 310 MHz Up to 5 permanent PINs and Up to 10 unique temporary PINs Up to 250 permanent PINs and Up to 10 unique temporary PINs KPW250 LiftMaster Security+® 315 MHz LiftMaster Security+® 390 MHz Linear Multi-Code 300 MHz KPW5 KPW250 Specifications Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9V lithium battery Operating temperature range . . . . . . . . . . . . . . . . . . . . . . . . . -40°F to 140°F (-40°C to +60°C) Storage and shipping temperature range . . . . . . . . . . . . . . .-40°F to 140°F (-40°C to +60°C) Enclosure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NEMA 3R INSTALLATION To prevent possible SERIOUS INJURY or DEATH from a moving gate or door: • ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with remote controls. • Activate gate or door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel. • ALWAYS keep gate or door in sight until completely closed. NEVER permit anyone to cross path of moving gate or door. 1. Choose a mounting location suitable for your application such as a wall, flat surface, or a pedestal with a 3" x 3" mounting pattern (LiftMaster gooseneck pedestal post models PED42 or PED64). Battery Cover Faceplate 2. Unlock and remove the faceplate from the mounting plate. 3. Mount the mounting plate to the desired surface and secure with 1/4" screws or bolts (not provided). Mounting plate 4. Remove the battery cover using a Phillips screw driver. Install the battery (provided) and re-install inner cover. Battery 5. Reattach the faceplate to the mounting plate and lock with the key. BASIC PROGRAMMING The Wireless Commercial Keypad must be put into programming mode prior to any of the programming steps below unless otherwise indicated. The keypad backlight will remain on if the product is in programming mode. While in programming mode, if an invalid code is entered, an error tone will sound, but the keypad will remain in programming mode. After 60 seconds of inactivity, the keypad will exit the programming mode. The 6-digit Master Code is used to prevent unauthorized access to the system. A Master Code is required (factory default code: 888888) to operate the Wireless Commercial Keypad. It is highly recommended to change and record your unique Master Code. Set Master Code Programming Step 1. Enter program mode 2. Update Master Code 3. Exit Program Mode Keystroke Combination Indicator (Master Code) # Long tone 09 # (New 6-digit Code) # (New 6-digit Code) # Long tone Keypad backlight will turn off ** Program a PIN Programming Step 1. Enter program mode 2. Set new pin 3. Exit Program Mode Keystroke Combination (Master Code) # 01 # (New 4-digit PIN) # (new 4-digit PIN) # ** Indicator Long tone Long tone Keypad backlight will turn off NOTE: An error tone will sound if the maximum number of PINs is exceeded or if user tries to program a PIN already programmed in the memory. PROGRAM TO OPERATOR LiftMaster NOTE: The Master Code and a PIN need to be set before the gate operator can be programmed. See Basic Programming, page 2. KPW5 - The frequency and encryption are set at the factory. Proceed to Step 4. KPW250 - The frequency and encryption are set at the factory for LiftMaster Security+ 2.0 (tri-band 310, 315, and 390 MHz) operators. Proceed to Step 4. For LiftMaster Security+ (315 MHz or 390 MHz), the frequency and encryption need to be set. Proceed to Step 1. 1. Enter program mode: (Master Code) # Set frequency and encryption (KPW250 only): • LiftMaster Security+ 315 MHz - Press 03 # 2 #. A long tone will sound. • LiftMaster Security+ 390 MHz - Press 03 # 3 #. A long tone will sound. • To reset factory default - Press 03 # 1 #. A long tone will sound. 3. Exit Program Mode: #. ** 4. Press the Learn Button on the operator. 5. Within 30 seconds- Enter a valid 4-digit PIN then press #. A long tone will sound. Linear Multi-Code KPW250 ONLY 1. Locate the DIP switch sequence on the operator and record it. If DIP switch is in the “up” or “on” (CLOSED) position place a 1, “down” or “off” (OPEN) position place a 0 in the corresponding box in the chart below. NOTE: Leave any unused switch locations blank. DIP Switch Sequence 10 UP / ON (CLOSED) DOWN / OFF (OPEN) Write the DIP switch 10-digit sequence: ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ 2. Enter program mode: (Master Code) #. A long tone will sound. 3. Set Linear Multi-Code frequency and encryption: Press 03 # 4 #. A long tone will sound. 4. Enter the DIP Switch sequence (Use ONLY 1 and 0). Press #. A long tone will sound. 3. Exit Program Mode: ** #. NOTE: When entering the DIP Switch sequence 3 beeps will sound if an incorrect number of entries is input. Once an operator has been programmed, enter a valid 4-digit PIN and the # key to activate the operator. ADDITIONAL PROGRAMMING The Wireless Commercial Keypad must be put into programming mode prior to any of the programming steps below unless otherwise indicated. Set Temporary PIN A temporary 4-digit PIN can be programmed to allow access to visitors (maximum of 9 uses). The temporary PIN cannot be the same as any previously programmed PIN. The keypad will store up to 10 unique temporary PINs. Programming Step Keystroke Combination (Master Code) # 1. Enter program mode 2. Set Temporary PIN 05 # (New temporary 4-digit PIN) # (New temporary 4-digit PIN) # Number of uses (9 maximum) # 3. Exit Program Mode Indicator Long tone Long tone ** Keypad backlight will turn off Delete Permanent and Temporary PIN Programming Step Keystroke Combination (Master Code) # 1. Enter program mode 2. Delete PIN 07 # (4-digit PIN to be deleted) # (4-digit PIN to be deleted) # 3. Exit Program Mode Indicator Long tone Long tone ** Keypad backlight will turn off Reset Master Code Resetting the Master Code will not remove PINs or temporary PINs from memory and will not change the frequency and encryption type. After resetting the Master Code, the keypad will not operate any previously programmed operators until they are reprogrammed. To reset the Master Code to the factory default (888888): 1. Unlock and remove the faceplate. 2. Press and hold the RESET button on the control board for 6 seconds, a long tone sounds indicating the Master Code has been reset. Reset Keypad Resetting the keypad will erase the Master Code, all permanent PINs, all temporary PINs, and frequency and encryption settings. All settings will be set to factory default. After resetting, the keypad will not operate the previously programmed operators until they are reprogrammed. To reset the keypad: 1. Unlock and remove the faceplate. 2. Press and hold RESET button on the control board for 6 seconds until a long tone sounds then release. 3. Press and hold RESET button on the control board for 15 seconds, 3 long tones will sound indicating the keypad has been reset. Lockout Mode (Default is ON) If the keypad receives five consecutive invalid PINs, the keypad will enter lockout mode and will not accept any keypad inputs for 30 seconds. After 30 seconds, the keypad will begin accepting new inputs. Programming Step 1. Enter program mode 2. Set Lockout mode to ON: 3. Exit Program Mode Keystroke Combination (Master Code) # 02 # 1 # Programming Step 1. Enter program mode 2. Set Lockout mode to OFF: 3. Exit Program Mode Keystroke Combination (Master Code) # 02 # 0 # Indicator Long tone Long tone Keypad backlight will turn off ** Indicator Long tone Long tone Keypad backlight will turn off ** BATTERY To prevent possible SERIOUS INJURY or DEATH: • NEVER allow small children near batteries. • If battery is swallowed, immediately notify doctor. To reduce risk of fire, explosion or chemical burn: • Replace ONLY with 9V Lithium battery. • DO NOT recharge, disassemble, heat above 212° F (100° C) or incinerate. The 9V Lithium battery should produce power for up to 5 years. To replace the battery: 1. Unlock and remove the faceplate from the mounting plate. 2. Remove the battery cover using a Phillips screw driver. 3. Remove the old battery and install new 9V Lithium battery. Re-install inner cover. 4. Reattach the faceplate to the mounting plate and lock with the key. 5. Dispose of old battery properly. Battery Cover Faceplate Mounting plate Battery TROUBLESHOOTING Symptom: The keypad will not program to the operator. Cause: The keypad is programmed to the wrong frequency and encryption. Solution: Program the keypad to match the operator's frequency and encryption (see page 3). Symptom: The backlight and tone on the keypad no longer work. Cause: Battery may be dead. Solution: Replace battery with 9V Lithium battery. ONE YEAR LIMITED WARRANTY LiftMaster warrants to the first consumer purchaser of this product that it is free from defect in materials and/or workmanship for a period of 1 year from the date of purchase. NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. LiftMaster.com 1-800-528-2806 REVIEW COPY
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author : mrutledg Create Date : 2015:01:21 15:52:30-07:00 Modify Date : 2015:01:21 15:53:13-07:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 10.1.1 (Macintosh) Format : application/pdf Creator : mrutledg Title : 01-37534 REVIEW.indd Creator Tool : Adobe InDesign CS6 (Macintosh) Metadata Date : 2015:01:21 15:53:13-07:00 Document ID : uuid:c7a8fe77-1cee-aa42-8bdc-5de481739879 Instance ID : uuid:97383ad6-fa45-484d-8c08-e497050bcbd7 Page Count : 5EXIF Metadata provided by EXIF.tools