Chamberlain Wireless EC1 Echo Remote User Manual Model OPG K5 K250

Chamberlain Wireless Products Inc. Echo Remote Model OPG K5 K250

User Manual

Download: Chamberlain Wireless EC1 Echo Remote User Manual Model OPG K5 K250
Mirror Download [FCC.gov]Chamberlain Wireless EC1 Echo Remote User Manual Model OPG K5 K250
Document ID879210
Application ID1MTBATDyoGQjQBglcewNIw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize10.97kB (137074 bits)
Date Submitted2007-12-13 00:00:00
Date Available2007-12-17 00:00:00
Creation Date2007-12-11 14:55:01
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2007-12-11 14:55:10
Document TitleModel OPG-K5/K250
Document CreatorAcrobat PDFMaker 7.0 for Word
Document Author: Tammy

Universal Wireless Solutions
Oracle
(TM)
Echo Remote
Compatibility:
•
•
•
Compatible with Oracle GCU (Gate Controller
Unit)/DFGCU (Dual Frequency Gate Controller
Unit), up to 4 units
Compatible with Oracle UltraRX 900 Receiver
Module
Oracle Gate Controller Unit (GCU)/Dual Frequency
Gate Controller Unit (DFGCU). Can be used alone (up
to 4 GCU/DFGCU’s) or in combination with Oracle
GAP and other Access Control and Communication
products.
Model
ModelOPG-K5/K250
ERMT
12/11/2007
Patents Pending
Thank you for purchasing the
Oracle Echo Remote. This
product has been designed and
manufactured in the USA,
utilizing the highest quality
standards available.
Features:
•
•
•
•
•
•
•
•
•
For: Gates, Garage Doors, Security Systems, Lighting and anything Electric!
4 Button, Multi Channel design, can control 4 devices
Lithium Battery Lasts for Years and will not be effected by high vehicle temperatures and humidity
Over 1000 Feet Of Range through multiple channels, chosen automatically
Audible and Visual Indication Of Command Receipt, as well as indication of failure
Automatic Retry of Command on Multiple Radio Channels
125 Channel, Digital, Ultra-Secure, 900 MHz
Built-in Unique ID as well as "Learning" of Network ID. WEIGAND compatible
All functions Performed automatically by Built-in Microprocessor
Setup Instructions
1: Setting up the Echo Remote:
• Will the Echo Remote (ERMT) be used with an ULTRX900-R Unit in Receiver Mode?
ƒ No: Go to Step 2.
ƒ Yes: Place the Ultra RX 900 Unit in Learn Mode by disconnecting the power and waiting at
least 5 seconds before reapplying power.
- Within 15 seconds, press the large button on the remote.
- The Ultra RX 900 Unit will buzz indicating success.
- Proceed to Step 5.
2: Setting up the Echo Remote:
• Will the Echo Remote be used with a Gate Access Panel (GAP) or Keypad (OWK) that includes a
GCU or ULTRX900-R as the gate activator?
ƒ No: Go to Step 3.
ƒ Yes: The Echo Remote needs to be taught directly to the Active Unit (GAP or OWK). To
put the Echo Remote in Learn Mode, press the large button, button 2 and button 4 at the
same time, for 1 second and release.
- On the GAP or Keypad Unit, enter in the Master Pin Number, followed by 05.
- The remote will give an acceptance beep indicating success.
- Proceed to Step 6.
3a: Setting up the Echo Remote:
• Will the Echo Remote be used with a Gate Controller Unit (GCU) or a Dual Frequency Gate
Controller Unit (DFGCU) as the gate activator? NOTE: If activating an Echo remote directly
to a GCU/DFGCU, there can be NO other Primary Gate Access Unit in the network.
ƒ No: Go to Step 4.
ƒ Yes: Press the Learn button on the GCU/DFGCU once, until the LED lights up solid, and
release.
- Within 5 seconds, on the Echo Remote press the large button, button 2 and button 4 at the
same time, for 1 second, until the LED lights up, and release.
- The LED on both units will double blink, 3 times, and the remote will beep, indicating
success.
- Proceed to Step 3b.
3b: Setting up the Echo Remote:
• Will you be using more than 1 Echo Remote?
ƒ No: Go to Step 3c.
ƒ Yes: NOTE: Before starting this step, please make sure you disconnect power to the
GCU/DFGCU. On the additional Echo Remote, press the large button, button 2 and
button 4 at the same time, for 1 second, until the LED lights up, and release.
- Within 5 seconds, on the main Echo Remote (the one activated to the GCU/DFGCU),
press the large button only, 1 time.
- The LED on the additional unit will double blink, 3 times, and the LED on the main unit
will blink twice, indicating success.
- For any additional remotes please repeat Step 3b for each unit that will be used.
- Proceed to Step 3c.
3c: Setting up the Echo Remote:
• Will you be using more than 1 GCU/DFGCU with your Echo Remotes?
ƒ No: Go to Step 6.
ƒ Yes: NOTE: This will allow up to (4) gate controllers to be activated independently by
each of the 4 buttons based on their controller ID# (1-4)..
Setting the Gate Controller ID (1-4)
ƒ If you are using more then one Gate Controller, the additional units must have their ID set.
The Gate Controller ID is set by changing dipswitches #1&2 in the Gate Control Unit (see
picture below)
GCU ID
ƒ
SW1
off
on
off
on
SW2
off
off
on
on
Example: The dipswitches for Gate
Controller #2 would look like this:
Proceed to Step 6.
4: Setting up the Echo Remote:
•
•
•
The Echo Remote needs to be taught directly to the Active Unit (MiniGAP (OMG) Unit, Basic Access
(OMG2) Unit, or Push-To-Exit (OPE) Unit)
To put the Echo Remote in Learn Mode, press the large button, button 2 and button 4 at the same time, for
1 second and release.
On the OMG, OMG2, or OPE, press and release the black learn button located inside the unit on the circuit
board.
- The remote will give an acceptance beep indicating success.
- Proceed to Step 6.
Clearing the Memory
If you get an error tone at any time or need to re-teach a unit, you will need to clear the memory.
• To clear the memory on an Ultra RX 900, hold down the learn button, located on the inside of the unit, until
the LED gives blinks 4 times, twice.
• To clear the memory on a GCU, hold down the learn button until the LED gives 4 double blinks.
• To clear the memory on a MiniGAP, Basic Access or Push-To-Exit, hold down the learn button until you
hear a low tone.
•
To clear the memory on an Echo Remote, press the large button, button 2 and button 4 at the same time
until you hear a beep.
General Operation
5: Using the Echo Remote with the ULTRX900-R in receiver mode:
•
Once the Echo Remote has been taught to the Ultra RX 900 unit, the buttons will automatically operate as follows:
ƒ Large Button – Activates Relay #1
ƒ Button #2 – Activates Relay #2
ƒ Button #3 – Activates Output 3
ƒ Button #4 – Activates Output 4
See the ULTRX900-R Instruction manual for more detailed instructions.
6: Using the Echo Remote with an Active Unit:
•
Once the Echo Remote has been taught to a GAP, Keypad, MiniGAP, Basic Access, Push-To-Exit, or DFGCU, the
buttons will automatically operate as follows:
Large Button – Activates GCU #1
Button #2 – Activates GCU #2
Button #3 – Activates GCU #3
Button #4 – Activates GCU #4
Note: If the Echo Remote has activated GCU 2, 3, or 4, and one of those GCU’s is removed from the network, the
corresponding button, if pressed, will give a 6 tone error signal.
If there is only 1 GCU, then buttons 2, 3, & 4, will do nothing.
FCC STATEMENT
This device complies with part 15 of the FCC Rules.
Part 15.21
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate
the equipment.
International Electronics, Inc.
FCC ID: JLFEC1
Country Of Origin: USA
Warranty: This product is warranted to be free of defects for the period of One Year from the date of purchase. The warranty covers parts, labor, and return
shipping to you, but not all accessories. IEI will repair or replace any defective product at our discretion. Warranty does not cover misuse or damage other than due to
normal operating conditions. If you need to send the system to IEI for repair, contact IEI for a Return Authorization number via email: techsupp@nwlink.com.
Packages without a Return Authorization number will be rejected.
Universal Wireless Solutions
Designed and Manufactured In the USA.
A manufacturer’s full One Year Warranty covers this product.
See www.WirelessGateAccess.com for technical information and questions

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Company                         : IEI
Source Modified                 : D:20071211225429
Creator Tool                    : Acrobat PDFMaker 7.0 for Word
Modify Date                     : 2007:12:11 14:55:10-08:00
Create Date                     : 2007:12:11 14:55:01-08:00
Metadata Date                   : 2007:12:11 14:55:10-08:00
Document ID                     : uuid:67f92423-8cfa-4cd5-9a78-42b7fe9ffdeb
Instance ID                     : uuid:257985df-df31-4642-a9ca-56ab6d90321d
Version ID                      : 3
Format                          : application/pdf
Title                           : Model OPG-K5/K250
Creator                         : Tammy
Subject                         : 
Headline                        : 
Page Count                      : 3
Page Layout                     : OneColumn
Author                          : Tammy
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JLFEC1

Navigation menu