Chamberlain Wireless PTE2 Push to Exit User Manual Push To Exit 10 24

Chamberlain Wireless Products Inc. Push to Exit Push To Exit 10 24

User Manual

- 4 -Made With Pride In the USA.                                                                                                                                               A manufacturer’s full One Year Warranty covers this product.- 1 -Oracle(TM) Push To  Exit    Thank  you for  purchasing  one of  the  Oracle  Push  To  Exit products.  This  product  has been  designed  and manufactured  in  the  USA, utilizing  the  highest  quality standards available. One year limited WARRANTY   International Electronics Inc. (IEI) warrants this product to be free of defects in materials and workmanship, for one year. For a period of ONE YEAR following purchase, IEI will repair or replace  the  product  free  of  charge,  including  parts,  labor,  return  shipping  to  you,  and handling.   After the initial one year of operation, the limited lifetime warranty will cover parts, labor, and return  shipping  to  you,  with  a  minimal  handling  charge  specific  to  the  product,  as  listed below:  PUSH TO EXIT:   $20.00  If  you  have  installation  or  operation  questions  or  are  in  need  of  warranty  service,  please contact  our  Product  Support  department  by email  at  techsupp@nwlink.com  or  call  360-254-1564 Tuesday-Friday 7-5 Pacific  Time. If the issue  is not resolvable, a manufacturer’s warranty  repair order may be  issued. To have the product(s) sent for warranty service.    A Return Authorization number will be issued  for warranty service,  which must  be put on the outside of the package, to be received and handled properly.  Packages for warranty service may be sent to the following address. Packages with no RA# may not be accepted.  IEI 5913C NE 127th AVE,  Suite 800 Vancouver, WA  98682   Please include a note describing the problem that you are having and a copy of your original sales  receipt  (within  the  first  year).  If  the  warranty  service  is  outside  the  first  year,  please include a check  made  out  to  IEI,  based on the list of handling  fees, shown above. Please note that you may need to send multiple units for warranty service, testing, and upgrading, though only the applicable fee for handling the failed unit(s) will be charged.   Please allow 2-4 weeks for service and return shipping. If an EXPEDITED repair/replacement is requested, a 100% surcharge applies. In this case, please write EXPEDITED after the RA number.  IEI  will  attempt  to  return  expedited  repair  orders  within  one  week,  except  during holidays.  All repairs or replacements are at the discretion of the Manufacturer.  This warranty excludes items  that  have been abused,  altered, incorrectly installed, or  repaired  by an unauthorized person. Changes or modifications not expressly approved by the Manufacturer could void the user’s authority to operate the equipment. The manufacturer is not responsible for any radio or  TV  interference  caused  by  unauthorized  modifications  to  this  equipment.    Such modifications  could  void  the  user’s  authority  to  operate  the  equipment.  This  warranty  is limited to the product only. No consequential damages are covered. This device complies with part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  International Electronics, Inc. FCC ID:  JLFPTE1 Country Of Origin:  USA •  Completely Wireless  •  Up to 1000 Foot Range •  Algorithmically Secure  •  UV Hardened ABS Enclosure  •  Button Light When Motion Detected  •  Audible Confirmation  •  Pedestal or Surface Mount  •  Invisible to Lightning     OPE2Patents Pending7/25/2007
DSW 1 DSW 2OFFOFFONOFFOFFONONONStep 1 & 2 must occur within 5 seconds of each other.ACTIVATING A PUSH TO EXIT TO AN EXISTING MINIGAP NETWORKStep 1 & 2 must occur within 5 seconds of each other.                               PUSH TO EXIT- 2 - - 3 -                      GCU DIPSWITCH SETTINGSGCU#1                       CLEARING THE MEMORYStep 1 & 2 must occur within 5 seconds of each other.              ACTIVATING A PUSH TO EXIT TO A GCU         Step 1 & 2 must occur within 5 seconds of each other.ACTIVATING A PUSH TO EXIT TO AN EXISTING KEYPAD NETWORK #2#3#4                       USING THE PUSH TO EXITACTIVATING A PUSH TO EXIT TO AN EXISTING GAP NETWORKThe  Push  Is  Exit  is  designed  to  be  activated  into  an  existing  Gate Access Network. Install 4 ‘AA’ batteries into the Push To Exit.  Lithium are preferred in cold climates. 1.  Press the LEARN button on a Push To Exit.    2.   On the Gate Access Panel (GAP),     Enter the Master Pin Number (for example):      Followed by:  The  Push  To  Exit  will  respond  with  a  beep  indicating  a  successful activation.   12340 5NOTE:  If  the  GCU  has  already  been  activated  to  a  Gate  Access  Panel  (GAP), Keypad, or MiniGAP, then the Push To Exit should also be activated to the GAP, Keypad, or MiniGAP 1.  Press the LEARN button on the GCU.    2.  Press the LEARN button on the Push To Exit.  The  Push  To  Exit  will  respond  with  a  beep  indicating  a  successful activation.    The Push Is Exit is factory set to control GCU #1. Simply press the button to exit. Hold down the learn button until you hear the beep. 1.  Press the LEARN button on the Push To Exit.    2.  Press the LEARN button on the MiniGAP.  The  Push  To  Exit  will  respond  with  a  beep  indicating  a  successful activation. 1.  Press the LEARN button on the Push To Exit.    2.  Press the LEARN button on the Keypad.  The  Push  To  Exit  will  respond  with  a  beep  indicating  a  successful activation. OPE2Patents Pending7/25/2007

Navigation menu