Chamberlain Elite El25 Users Manual Keypad Quickstart

ELITE EL25 114A3042

EL25 to the manual 5cb4f683-6925-9a04-bd5c-43b431b6c304

2015-01-25

: Chamberlain Chamberlain-Elite-El25-Users-Manual-214100 chamberlain-elite-el25-users-manual-214100 chamberlain pdf

Open the PDF directly: View PDF PDF.
Page Count: 26

DownloadChamberlain Chamberlain-Elite-El25-Users-Manual- EL25 Keypad Quickstart  Chamberlain-elite-el25-users-manual
Open PDF In BrowserView PDF
®

™

Quickstart
EL25 Keypad Programming Guide
Telephone entry/access control system with a 25 directory code capacity
This Quickstart Guide is intended to highlight some applications. These instructions are not intended to be
comprehensive. Please consult the Keypad Programming Manual for complete information.

© 2005 The Chamberlain Group, Inc.
All Rights Reserved

Guide for Programming the EL25

Programming
Number

***
0
1
2
3
4
5
6
7
9
10
11

Description of Task

Factory
Setting

Programming Procedure

Entering Programming Mode

*** (6 Digit Password)

Exiting Programming Mode

0#

Change or Verify the Unit's Password
Set Unit ID Number and No. in Chain

000000

Unit ID 1, Chain No. 1 2 # (unit ID number, 1-7) # (Number of Units in Chain, 1-7) #

Set the Clock
Enable/Disable Daylight Savings Time
Set Visitor Talk Time

1 # (1 to change; 2 to verify) # (six-digit code) #

3 # yymmdd # (day of the week) # hhmm #
Enabled
60 Seconds

4 # (0 = disable; 1 = enable) #
5 # (15 – 250 seconds) #

Set Directory Code Length

2 Digits

6 # (1 or 2) #

Set Entry Code Length

4 Digits

7 # (3-9) #

Enable/Disable Call Waiting

Enabled

9 # (0 = disable; 1 = enable) #

Enable/Disable Do Not Disturb Schedule

Disabled

10 # (directory code) # (0 = disable; 1 = enable) #

Enable/Disable Unlock Time Zone

Enabled

11 # (0 = disable; 1 = enable) #

12

Enable/Disable Anti-Passback

Disabled

12 # Enable/Disable True Anti-Passback (0 = disable;
1 = enable) # Enable/Disable Timed Anti-Passback (0
= disable; 1 = enable) #

13

Set Anti-Passback Time

3 Minutes

13 # (1-60 minutes) #

14

Set Maximum Number of Rings
Allowed Before Aborting Attempt

15

Set Standard Single Ring or Double
Ring Response

16

Number of Rings Before Unit Answers

5 Rings

16 # (0 – 15) # Each unit in chain must have same setting

17

Set “Strikes” and “Out”

3 Errors

17 # (max errors, 0-5) #

18
19

Set Speaker Volume

5

18 # (0 = mute; 1-10, 1 is low and 10 is high) #

Set Microphone Volume

5

19 # (0 = mute; 1-10, 1 is low and 10 is high) #

20
21
22

Enable/Disable the Telco Mode

Enabled

20 # (0 = disable; 1 = enable) #

Enable/Disable Direct Commands

Enabled

21 # (0 = disable; 1 enable) #

Enable/Disable Voice Mail

Disabled

22 # (0 = disable; 1 = enable) #

23

Enable/Disable Access Granted Beeps

Enabled

23 # (0 = disable; 1 = enable) #

24

Enable/Disable Real-Time Monitoring

Disabled

24 # (0 = disable; 1 = enable) #

Optional Steps Indicated with a

Important:

5 Rings
0 = One
Long Ring

14 # (1 – 9) #
15 # (0 – 1; 0 = one long ring, 1 = double ring) #

Background, all other steps are Required

The Pound Key (#) must be used as Data Field Separator and to Save Data at the end of the sequence.
Time must be entered using a 24-hour format (8AM=0800, 3PM=1500 etc.)
2 Short Beeps: Programming input is valid. 1 Long Beep: Input is not valid.
If you make an error during an entry, press the asterisk key ( ) to begin again.

*

Page 1

Programming
Number
28
29

Description of Task

Factory
Setting

Programming Procedure

Restore Factory Settings

28 # 101010 #

Reset the Unit

29 # 101010 #

30

Create a Time Zone

30 # (time zone number, 2-63) # (segment number;
99) # (starting time = hhmm; 99) # (ending time =
hhmm) # (day of week, 1-8; 1 = Sunday; 7 = Saturday;
8 = holiday) #

31

Assign Door Auto Lock/Unlock Time Zone

32

Setting Holidays

32 # (1 = add, 2 = verify, 0 = delete) # (yymmdd;
yy = year, mm = month, dd = day of the month) #

40

Add a Basic Directory Code

40 # (directory code) # (phone number) # (phone
extension) #

41

Add or Edit a Full Function Directory
Code

41 # (directory code) # (phone number) # (phone ext)
# (DnD schedule number, 0-63) # (enable/disable call
fwd) # (call fwd schedule number, 0-63) # (new call
fwd phone number) # (call fwd phone ext) #

44

Change a Directory Code ONLY

44 # (new directory code) # (directory code to change) #

45

Activate/Deactivate a Directory Code

45 # (directory code) # (0 = deactivate; 1 activate) #
(0 = don't use start; 1 = use start) # (Start Date =
yymmdd) # (Start Time = hhmm) # (0 = don't use
end; 1 = use end) # (End Date = yymmdd) # (End
Time = hhmm) #

46

Enable/Disable Call Forwarding
(Directory Calls)

47
48

Verify a Directory Code

47 # (directory code) #

Delete a Directory Code

48 # (directory code) #

49

Enable/Disable Call Forwarding and Do
Not Disturb Schedule with Residence
“Call” Button Only

49# DnD Enable (1)/Disable (0) # DnD Schedule (063) # Call Forward Enable/Disable (0 = disable; 1 =
enable) # Call Forward Schedule (schedule number,
0-63 # (new call forward phone number) #
(call forward phone extension) # (call forward
extension delay, 0 to 30 sec.) #

50

Add a Basic Entry Code

51

Add/Edit a Full Function Entry Code

54
55

Change an Entry Code ONLY

54 # (entry code to change) # (new entry code) #

Verify an Entry Code

55 # (entry code) #

Activate/Deactivate an Entry Code

56 # (entry code) # (0 = deactivate; 1 activate) # (0 =
don't use start; 1 = use start) # (Start Date = yymmdd)
# (Start Time = hhmm) # (0 = don't use end; 1 = use
end) # (End Date = yymmdd) # (End Time = hhmm) #

56

Optional Steps Indicated with a

Disabled

Disabled

Disabled

31 # (door 1-4) # (time zone, 2-63; 99) #

46 # (directory code) # (0 = disable; 1 = enable)
(schedule number, 0-63) # (new call forward phone
number) # (call forward phone extension) #

50 # (entry code) #
51 # (entry code) # (schedule for door 1, 0-63) #
(schedule for door 2, 0-63) # (schedule for door 3,
0-63) # (schedule for door 4, 0-63) #

Background, all other steps are Required

To enter programming mode from the EL25:
and the 6-Digit Password (2 short beeps will be heard)
Press
Exiting programming mode allows changes to take effect

***

Page 2

Programming
Number
57

Description of Task

Factory
Setting

Delete an Entry Code

Programming Procedure
57 # (entry code) #

60

Assign Each External Access Control
Device a “Door Number” (Step 1 of 4)

No Device
Assigned

60 # (device 1-4) # (device type 0-2; 0 = no device,
1 = wiegand card reader or keypad, 2 = RF receiver) #
(door 1-4) #

61

D1=Relay 1
D2=Relay 2
D3=Relay 3
D4=Relay 4

61 # (door 1-4) # (relays to activate 0000-1111) #

Assign “Each” Door Number to One or
More Relays (Step 4 of 4)

63

Assign Door Use Time Zone

64

Set Anti-Passback Entry/Exit for
Specific Devices

65

Order of relay is: relay 4 – relay 3 – relay 2 – relay 1 for an
example if you want relay 4 active you would enter 1000, if
you want relay 1 active you would enter 0001

D1,D2,D3,D4=Enabled 63 # (door 1-4) # (time zone, 0-63) #

Disabled

64 # (device 0-4) # (0-3; 0 = disable,
1 = set device to timed anti-passback,
2 = set device to true anti-passback - entrance,
3 = set device for true anti-passback - exit) #

Set Each “Relay Type” to get the
Appropriate Response (Step 2 of 4)

All Relays =“Strike”

65 # (relay 1-4) # (0-5; 0 = unknown, 1 = strike,
2 = shunt, 3 = CCTV, 4 = alarm, 5 = control) #

66

Set Each Relay's “Activation Time”
(Step 3 of 4)

All Relays =
10 seconds

66 # (relay number 1-4) # (activation time, 1-300
seconds) #

67

Configure an Exit Device (REX)

R1=Door 1
R2=Door 2
R3=Door 3
R4=Door 4

67 # (REX number 1-4) # (select REX option: 0 =
disabled, 1 = use your door settings or 2 = use
specific relay(s) 0000-1111) #
Order of Relays are 4321

68

Configure a Door Sensing Device

DS1=Door 1
DS2=Door 2
DS3=Door 3
DS4=Door 4

68 # (sensor number 1-4) # (select sensor option: 0 =
disabled, 1 = use your door settings or 2 = use
specific relay(s) 0000-1111) #
Order of Relays are 4321

69

Assign a Postal Lock Switch to Door No.

70

Door 1

69 # (door 0-4; 0 = no postal lock) #

Set Relay(s) for AutoCall

No Relays
Assigned

70 # (relays to activate 0000-1111) #
Order of relays are 4321

71

Set the Default Card Type

30-bit Cards

73

Set the Default Facility Code

74

Enable/Ignore Facility Code when Card is Used

80

Add a Basic Card

80 # (card PIN code) # (facility code) # (card type, 26
or 30) #

81

Add or Edit a Full Function Card

81 # (card PIN code) # (facility code) # (card type, 26
or 30) # (schedule for door 1, 0-63) # (schedule for
door 2, 0-63) # (schedule for door 3, 0-63) #
(schedule for door 4, 0-63) #

Add a Card Group

82 # (card PIN code start range) # (card PIN code
end range) # (facility code) # (card type, 26 or 30) #
(0 = deactivate; 1 = activate) # (schedule for door 1,
0-63) # (schedule for door 2, 0-63) # (schedule for
door 3, 0-63) # (schedule for door 4, 0-63) #

82

Optional Steps Indicated with a

Important:

0
Ignored

71 # (26 or 30) #
73 # (0-255) #
74 # (0 = disable; 1 = ignore) #

Background, all other steps are Required

The Pound Key (#) must be used as Data Field Separator and to Save Data at the end of the sequence.
Time must be entered using a 24-hour format (8AM=0800, 3PM=1500 etc.)
2 Short Beeps: Programming input is valid. 1 Long Beep: Input is not valid.
If you make an error during an entry, press the asterisk key ( ) to begin again.

*

Page 3

Programming
Number

Description of Task

Factory
Setting

Programming Procedure

85

Replace a Card

85 # (lost or stolen card PIN code) # (facility code) #
(card type, 26 or 30) # (new card PIN) # (new facility
code) # (new card type, 26 or 30) #

86

Verify a Card

86 # (card PIN code) # (facility code) # (card type, 26
or 30)

87

Activate or Deactivate a Card

87 # (card PIN code) # (facility code) # (card type, 26
or 30) # (0 = deactivate; 1 = activate) # (0 = don't use
start; 1 = use start) # (Start Date = yymmdd) # (Start
Time = hhmm) # (0 = don't use end; 1 = use end) #
(End Date = yymmdd) # (End Time = hhmm) #

88

Delete a Card

88 # (card PIN code) # (facility code) # (card type, 26
or 30) #

90

Add a Basic Transmitter

90 # (transmitter PIN code) # (facility code) #
(sequence number) # (ID number) # (button number) #

Add or Edit a Full Function Transmitter

91 # (transmitter PIN code) # (facility code) #
(sequence number) # (ID number) # (button number)
# (schedule for door 1, 0-63) # (schedule for door 2,
0-63) # (schedule for door 3, 0-63) # (schedule for
door 4, 0-63) #

Add a Group of Transmitters at Once

94 # (transmitter PIN code start range) # (transmitter
PIN code end range) # (facility code) # (sequence
number) # (ID number) # (button number) #
(0 = deactivate; 1 activate) # (schedule for door 1,
0-63) # (schedule for door 2, 0-63) # (schedule for
door 3, 0-63) # (schedule for door 4, 0-63) #

95

Replace a Lost Transmitter

95 # (transmitter PIN to change) # (facility code) #
(sequence number) # (ID number) # (button number)
# (new transmitter PIN) # (new facility code) # (new
sequence number) # (new ID number) # (new button
number) #

96

Verify a Transmitter

96 # (transmitter PIN code) # (facility code) #
(sequence number) # (ID number) # (button number) #

98

Activate or Deactivate a Transmitter

98 # (transmitter PIN code) # (facility code) #
(sequence number) # (ID number) # (button number)
# (0 = deactivate; 1 activate) # (0 = don't use start; 1 =
use start) #(Start Date = yymmdd) # (Start Time =
hhmm) # (0 = don't use end; 1 = use end) #(End Date
= yymmdd) # (End Time = hhmm) #

100

Deactivate a Button on a Transmitter
and/or Delete a Transmitter

100 # (transmitter PIN code) # (facility code) #
(sequence number) # (ID number) # (button number) #

102

Configure “Door Held Open” Alarm
Feature

103

Configure “Door Forced Open” Alarm
Feature

91

94

Optional Steps Indicated with a

Disabled

102 # (alarm option; 0 = disable, 1 = enable until
relay time expires, 2 = enable until alarm clears) #
(relay group, 0000-1111) #
Order of relays is 4321

Disabled

103 # (alarm option; 0 = disable, 1 = enable until
relay time expires, 2 = enable until alarm clears) #
(relay group, 0000-1111) #
Order of relays is 4321

Background, all other steps are Required

Page 4

Programming
Number

Description of Task

Factory
Setting

Programming Procedure

104

Configure “Strikes and Out” Alarm
Feature

Disabled

104 # (alarm option; 0 = disable, 1 = enable until
relay time expires, 2 = enable until alarm clears) #
(relay group, 0000-1111) #
Order of relays is 4321

105

Enable or Disable Anti-Passback
Forgiveness at Midnight

Enabled

105 # (0 = disable; 1 = enable) #

109

Override Telephone Company
Answering Service

110

Set a Phone Number's Extension Delay
Time

111

Verify Multi-Unit Number

113

Dial “0-9” First to Get an Outside Line
Using a Automated Phone System

Disabled

113 # (0 = disable; 1 = enable) # (0-9, when enabled) #

115

Set Alternative Prefixes

Normal

115 # (normal-00, mixed-01, asterisk-02, pound-03,
number-1n) # each unit in chain must have same setting

116

Change the Visitor Call Response Keys

9, 5, 3, 7, 2, 1,*

116 # (activate door 1) # (activate door 2) # (activate
door 3) # (activate door 4) # (call wait toggle) #
(extend talk time) # (hang up and deny access) #

120
121
122
123
124
131
201
202
203
204
205

Talk through the EL25 Speaker

120 #

Cycle Door

121 # (door 1-4) #

Latch Door “Open” Until...

122 # (door 1-4) # (end time = hhmm) #

Latch Door “Closed” Until...

123 # (door 1-4) # (end time = hhmm) #

Release Door “Now”

124 # (door 1-4) #

Cycle Relay “Now”

131 # (relay 1-4) #

Delete ALL Directory Codes

201 # 101010 #

Delete ALL Entry Codes

202 # 101010 #

Delete ALL Access Cards

203 # 101010 #

Delete ALL Transmitter Codes

204 # 101010 #

Delete ALL Time Zones

205 # 101010 #

Delete ALL Access Codes from Database

206 # 101010 #

206

Optional Steps Indicated with a

No
No Delay

109 # (0 = no; 1 = yes) # Default is “No”
110 # (directory code) # (phone extension delay) #
(call forward extension delay) #
111 #

Background, all other steps are Required

To enter programming mode from the EL25:
and the 6-Digit Password (2 short beeps will be heard)
Press
Exiting programming mode allows changes to take effect

***

Important:

The Pound Key (#) must be used as Data Field Separator and to Save Data at the end of the sequence.
Time must be entered using a 24-hour format (8AM=0800, 3PM=1500 etc.)
2 Short Beeps: Programming input is valid. 1 Long Beep: Input is not valid.
If you make an error during an entry, press the asterisk key ( ) to begin again.

*

Page 5

Programming Single Unit Overview

The EL25 can be programmed 3 different ways.
1 EL25 Keypad: You may use the keypad on the front panel. (Next Page)
2 Local/Remote DTMF Phone: You may use the keypad on a local or remote phone to program the system. The unit
responds to the DTMF signals generated by your touch-tone phone. (Next Page)
3 Direct/Modem Connection to a PC: In order to program the EL25 with a direct or modem connection, your PC must be
running Sentex's Windows®-compatible Versa XS software. (Not covered in this Quickstart Guide)

THIS guide will outline some programming for the EL25 from the keypad or
local/remote DTMF (Touch-Tone) phone ONLY.
For more information, refer to the Manuals and/or your installation dealer.

Procedure Required to Program the EL25:
1 1, 2 or 3 digit # Programming Number. (See “Quick Reference Guide” Tables for descriptions and procedures)
2 One or more Data Fields.
3 Pound Key (#) as a Data Field Separator and at the end of the programming sequence to Save the Data.

Notes:
• All data fields must be separated with the pound key (#).
Example: ( # Programming Number) # (Data Field) # (Data Field) # (Data Field) #
1
Required Step

2
Optional Step

3
Required Step

Required Step
Optional Step,
Press (#) to Skip.

4
Required Step

• Steps tagged with a ( ) are optional, press the pound key (#) to skip them. Note: Some steps are required
and must have data entered in them to continue, tagged with ( ).
• If you make an error during an entry, press the asterisk key (*) to cancel the step.
• When you correctly enter the entire programming sequence, the unit will respond with 2 short beeps
(see also System Feedback/Responses (Beeps)).

Example of a Programming Sequence: “
1st Pound Key:
Separates the 1st field.
Pound Key:
Separates the data field.

1

Changing the Password”
Last Pound Key:
Saves the data.

Enter
Programming
Mode
(Next page)
Programming Number:
1 changes or verifies
the password.

Exit
2 short
beeps Programming
Mode
(Next page)
Data Field:
1 changes the password

Data Field:
(The new password)

(2 verifies the password)

If you make an error during an entry, press the asterisk key ( ) to begin again.

*

Page 6

Programming Single Unit Overview

Programming Single Unit Overview

Programming Basics

Enter Programming Mode

***

Important: After entering programming mode for the first time, we suggest you change
the password to maintain the security of your system.
1

From the EL25 Keypad:
1 Press
2 Enter the (6) six-digit password. The default is six zeroes.

2 Short Beeps

The unit is now ready to accept programming instructions!
2

From the Residence Telephone:
1 When you hear the dial tone, press
1A If multiple EL25 units are sharing the same phone line, then a Unit ID Code (1-7) will need
to be entered at this time.
2 Enter the (6) six-digit password. The default is six zeroes.
3 Press

and the tone will stop.

The unit is now ready to accept programming instructions!
2

From the Remote Telephone:
1 Dial the unit's phone number.
Note: If the EL25 and an answering machine (or answering service) utilize the same phone line, let the line
ring at least (2) two times, hang-up, and call back within one (1) minute. The EL25 will answer on the
second call. If the unit does not answer, you may need to change the ring count.
2 When the EL25 picks up the call, you will hear 2 beeps.
3 Press
3A If multiple EL25 units are sharing the same phone line, then a Unit ID Code (1-7) will need
to be entered at this time.
4 Enter the (6) six-digit password. The default is six zeroes.
5 Press

and the beeps will stop.

The unit is now ready to accept programming instructions!

Exit Programming Mode

0

• Press

on the EL25 keypad and the unit will respond with 3 short beeps when disconnecting.

• Press

on the telephone and the unit will respond with 3 short beeps when disconnecting.
Press

when using a telephone or the EL25 to cancel

programming sequence and exit programming mode.

Page 7

Programming Single Unit Overview

Programming Single Unit Overview

If you will be programming the unit via modem, please refer to the Versa XS online help.

System Feedback / Responses (Beeps)

Programming Responses:
2 Short Beeps:
3 Short Beeps:

Programming step was valid.
Programming mode was exited.

1 Long Beep:

Input was not valid.

2 Long Beeps:

Duplicate entry code was entered.

3 Long Beeps:

Memory is full.

4 Long Beeps:

Unit has reset or is powering up.

Busy Signal:

Line is busy or Do Not Disturb feature is in effect.

Direct Command Responses:
5 Short Beeps:

Gate is closing by command.

10 Short Beeps

Gate is opening by command.

Other Responses:
1 Short Beep:

Key was pressed on the unit's keypad.

1 Beep:

Talk time for a visitor call is lapsing and the unit will beep once per second for the
last 10 seconds unless the talk time is extended.

Ring Back:

The unit is ringing the building.

10 Short Beeps: The unit has granted access.

Silence:

The keypad has struck out, the unit is being programmed from
another source, or an alarm condition exists.

Sending Direct Commands from the Resident's Phone
(NPBI / Single Family Residence ONLY)
You can send commands directly to the EL25 from your phone without being in programming mode.
This feature is only available for a single-family residence or a manager is sharing a phone line
with the EL25.
To Enter a Direct Command from a Residence Phone:
1 Lift the receiver and press
1A If multiple EL25 units are sharing the same phone line, then a Unit ID Code (1-7) will need
to be entered at this time.

The unit is now ready to allow direct commands only!
Example 1:

Example 2:

Enters direct command mode

Enters direct command mode for unit three

Page 8

Programming Single Unit Overview

Programming Single Unit Overview

The EL25 emits various audio tones to respond to input and to indicate certain conditions.

Up to seven (7) EL25s can be installed on a single telephone line. Each unit must have a “Unique
Unit ID” number and the “Number of Units in Chain” assigned to it.

Set the Unit ID Number and Number of Units in Chain:

2

The unit ID identifies each unit within a chain. Adding or removing EL25s will require the unit ID's to be re-entered.

Factory Setting: Unit ID 1 and Number of Units in Chain 1.
1 Press

Then

Important: This must be performed
for EACH unit in the Chain.

2 Unit ID Number (1-7), Then
3 Total Number of Units in Chain (1-7), Then

Example:

Unique Unit ID Sequencial Order

Unit ID “1”

Residence

Unit ID “2”

Unit ID “3”

Unit ID “7”

Telco Entrance Box
Demarcation Point

Number of Units in Chain “7”

Important:
EACH unit in the Chain must have the same “Rings Before Answer”. 16 Factory Setting - 5 Rings
EACH unit in the Chain must have the same “Alternate Prefix”. 115 Factory Setting - Normal

Verify Unit Number:

111

This allows you to verify a unit's number within a chain. When you perform this step, the unit will respond with the
number of beeps corresponding to its unit ID number. Two beeps, for example, mean the unit is number 2 in the chain.
Then

Note: You cannot program a unit within a multi-unit chain from a local/remote DTMF phone (Touch-Tone) unless
you know the unit's ID number. Therefore, you can only verify the unit number while programming from the unit's
front keypad.

If you make an error during an entry, press the asterisk key ( ) to begin again.

*

Page 9

Programming Multiple Units Overview

Programming Multiple Units Overview

Programming Multiple Units Overview

EL25 SetUp “Your Settings”
The EL25 comes preprogrammed with Factory Settings. When the unit is first installed,
you DO NOT need to program each feature.
Review the unit's factory settings before programming (see Quick Reference Guide in front for ALL the Factory
Settings).

Getting Started

EL25 SetUp “Your Settings”

1

Change the unit password to prevent any tampering with your system's database. When changing the password,
save a copy of it in a secure location. If you lose the password, you will not be able to enter into programming
mode. Factory Setting: 000000 (See Page 6)

Example:
1 Press

Then

1

2

3

Changes the unit's password to “123456”.
2 Change (1) or Verify (2) the Password. Then (#)
3 Enter New Password or Password to Verify (6 Digits). Then (#)

Set the Clock

3

An accurate clock is critical to the proper use of schedules, time zones and for accurately reporting transactions.
The system will adjust itself to daylight saving time if enabled.
1 Press

Then

2 Enter Date (yymmdd). Then (#)
3 Enter Day of week. Then (#)
1 = Sunday, 2 = Monday, 3 = Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, 7 = Saturday
4 Time of Day (hhmm). Then (#)
All time must be entered using a 24-hour format (8AM=0800, 3PM=1500 etc.)
Year

Month

Day

24-Hour Time

Example:
1

2

3

4

Sets the clock to 1PM, Saturday, January 1st, 2005.

Important: We recommend you check the clock after installation.

Change the Unit's ID and Chain Number for Multiple Unit Configurations ONLY

2

The Unit ID number identifies each unit within the chain. Setting the “Unit ID” and “Number of Units in the
Chain” are required so Versa XS can send or receive data to/from the correct units within the chain.
Factory Setting: Unit ID Number “1” and Number of Units in Chain “1”. (See Previous Page)

If you make an error during an entry, press the asterisk key ( ) to begin again.

*

Page 10

EL25 SetUp “Your Settings”

Change the Unit Password

Setup External Access Control Devices

What is a Door Number?
A Number (1-4) YOU assign to the EL25 unit to Identify the External Access Control
Devices wired to it. Up to 4 devices can be connected. Once identified, the unit will keep
the Same Door Numbers in other programming. The Internal Keypad is ALWAYS
Assigned to Door Number 1.

What is a Relay?
A relay is a device that reacts to an electric current to activate other devices. Allowing
the EL25 to lock or unlock a door/gate, shunt (bypass) alarm contacts, signal an alarm,
or turn on a camera wired to a closed-circuit television (CCTV). The relays can be
programmed to 5 different modes.

The 5 Modes of Operation are:
Strike Relay: A Strike Relay controls a door or gate by unlocking or opening it. It does not control any
other component associated with a system like Alarms, CCTV, etc.
Shunt Relay: A Shunt Relay is normally wired to an alarm and works with strike relays to shunt
(bypass) the alarm when the door is opened with a valid access code. If the door is forced open, the
system will not shunt the alarm and the alarm will be triggered.
CCTV Relay: A CCTV Relay activates the system's optional camera. The camera is wired to a closed
circuit television (CCTV). A camera can be activated when an alarm condition occurs or when a resident
enters a valid access code.
Alarm Relay: The Alarm Relay will activate another device, such as a siren, when 3 conditions occur. A
door is opened without a valid access code, A door is open past the allotted time programmed in, or too
many invalid codes are tried. Any of these will trigger the alarm relay.

Control Relay: The Control Relay can control another device such as an outdoor or indoor light near
the unit. For example, you could configure the system to turn on an entry light through a darkened area
after a resident enters a valid access code. Then the light would then turn off after a specified amount of
time.

Page 11

EL25 SetUp “Your Settings”

EL25 SetUp “Your Settings”

The EL25 must have all external access control device options configured into it, before many of
the other programming options can proceed. You must tell the unit “what it's wired to” and “how
you want the devices to behave.” To do this you must know what a “Door” Number is and what a
“Relay” is.

Configuring “YOUR” EL25
There are 3 sample configurations on page 14-16 to help you understand
the 4 step process needed to setup YOUR external access control devices.

Step 1 Assign Each External Access Control Device to a Door Number: When a valid access code is entered
into a external access control device, the Assigned door's relays will activate (See Below).

Step 2 Set Each Relay Mode for the Appropriate Response: There are 5 different relay modes (Previous Page).
Step 3 Set Each Relay's Activation Time: The relay time determines the amount of time the relay remains
activated. For example, when a strike relay activates to unlock a door, the relay activation time determines
how long the door will remain unlocked. (Next Page)

Step 4 Assign Each Door Number to One or More Relays: Defines which relays will activate when a resident
presents a valid access code to an external access control device. (Next Page)

Step 1 Assign Each External Access Control Device a “Door Number”:

60

To perform these 4 steps you MUST know EXACTLY where the External Access Control
Device(s) were wired in “Your” EL25! When the table on page 14 is completed by you or
your installer, this will help you understand “Your” personal layout. If you do not know
this, DO NOT PROCEED. Consult your Installer and/or refer to the installation manual for
assistance.
The EL25 can be equipped with Wiegand reader and radio frequency (RF) modules that allow your system to
accommodate external access control devices such as a Wiegand-compatible card reader (keypad) and RF
receiver. In order for the devices to work successfully, you must assign them a “Door Number”. When a
valid access code is presented to the device, the Assigned Door's Relays will activate.

Factory Setting: EL25 Keypad Always Assigned to Door 1, No Devices Assigned - 0
1 Press

4
1
Important: Allthroughepsmust
be
performed for EACH external access
control device of unit.

Then

2 Enter External Access Control Device Number (1-4). Then (#)
Internal Keypad is ALWAYS Assigned to External Access Control Device Number 0
3 Enter External Access Control Device Type (0-2). Then (#)

0 = Not Activated/No Device Assigned
1 = (Wiegand) Card Reader or Keypad Only
2 = RF Receiver

Note: A “Door Number” is a number
you assign to each external access
control device.

4 Assign a Door Number (1-4) to the Device. Then (#)

Example A:
1

2

3

4

Device “1” is a Radio Receiver and Assigned as Door “3”.

Example B:
1

2

3

4

Device “3” is a Card Reader or Keypad and Assigned as Door “4”.

Page 12

EL25 SetUp “Your Settings”

EL25 SetUp “Your Settings”

The relay mode determines what the relay will control (a door, alarm, CCTV, etc.). (Next Page)

Step 2 Set Each “Relay Mode” to get the Appropriate Response: 65
There are 5 different relay modes. The Relay Mode determines what the response will be when a valid access
code is entered (open a door, turn on an alarm, turn on a light then turn it off, turn on a CCTV, etc.).

Factory Setting: All Relays are Set at “1 - Strike”
1 Press

3
1
Important: Allthroughepsmust
be
performed for EACH Relay assigned
to the unit.

Then

3 Enter Relay Mode (0-5). Then (#)
0 = Not Used
3 = CCTV - activates system's optional camera.
4 = Alarm - activates another device (siren).
1 = Strike - controls a door/gate by unlocking/opening it.
2 = Shunt - bypasses the alarm under normal circumstances. 5 = Control - controls another device (on/off light).

Example:
1

2

3

Assigns Relay “2” as a Shunt Relay

Step 3 Set Each Relay's “Activation Time”:

66

This is the amount of time (in seconds) the relay remains activated. This will define the amount of time a
door cycles (unlocks, then relocks) or how long the CCTV camera remains on after being activated.

Factory Setting: All Relays are set at 10 seconds
1 Press

3
1
Important: Allthroughepsmust
be
performed for EACH Relay assigned
to the unit.

Then

2 Enter the Relay Number (1-4). Then (#)
3 Enter Activation Time (1-300 Seconds). Then (#)

Example:
1

2

3

When Activated, the Relay Number “4” will activate for “30” seconds.

Note: A relay that controls a gate operator must be set to activate for 2 seconds.

Step 4 Assign “Each” Door Number to One or More Relays:

61

When a valid access code is used at an external access control device (Door), the EL25 can be set to activate
one or more relays. Factory Settings: Door 1 Activates Relay 1; Door 2 Activates Relay 2;

Door 3 Activates Relay 3; Door 4 Activates Relay 4
1 Press

Then

3
1
Important: Allthroughepsmust
be
performed for EACH Door Number
assigned to the unit.

2 Enter Door Number (1-4). Then (#)

3 Enter Relays to be Activated (0000-1111). Then (#)
0 = Deactivate , 1 = Activate (1st digit=Relay 4, 2nd digit=Relay 3, etc.)
Relay 4 Relay 3 Relay 2 Relay 1

Example:
1

2

Deact

Deact Activate Activate

3

When a Resident uses a Valid Code at “Door 1”, Relay “1” and Relay “2” will Activate.

Page 13

EL25 SetUp “Your Settings”

EL25 SetUp “Your Settings”

2 Enter the Relay Number (1-4). Then (#)

“Your” Door Settings
Location

Door No. Relay

Relay
Mode

Relay Function

Relay Activation
Time (Seconds)

When “Your Door Settings” or “Door 1,2,3 or 4” are referenced throughout this guide,
this completed chart will outline how your EL25 system will function.
Sample: EL25 Controlling 1 Door (Page 16)
Device

Location

Door No.

Main Keypad
Front Door

Door 1

(REX) Exit Request

Relay Relay Mode

Relay Function

Relay Activation Time (Seconds)

Unlocks Door
Bypasses/Signals Alarm

10 sec.
40 sec.

Alarm

Sounds a Siren

10 sec.

CCTV

Activates Camera

10 sec.

1
2

Strike
Shunt

3
4

Sample: EL25 Controlling 2 Doors and a Vehicle Gate (Page 16)
Device

Location

Main Keypad and Postal Lock
Security Light

Front Door

Wiegand Card Reader
Transmitter

Back Door
Gate Operator

Door No.

Relay Relay Mode

Relay Function

Relay Activation Time (Seconds)

Door 1

1
2

Strike
Control

Unlocks Door
Turns on Security light

10 sec.
60 sec.

Door 2

3

Strike

Unlocks Door

10 sec.

Door 3

4

Strike

Opens Gate

10 sec.

Sample: EL25 Controlling 4 Doors (Page 17)
Device

Location

Door No.

Main Keypad
Wiegand Keypad

Front Door (Entrance)
Front Door (Exit)

Door 1

Wiegand Card Reader
Wiegand Card Reader

Manager’s Door

Back Door

Door 2
Door 3
Door 4

Relay Relay Mode

Relay Function

Relay Activation Time (Seconds)

1
2

Strike
Strike

Unlocks Door
Unlocks Door

10 sec.
10 sec.

3

Strike

Unlocks Door

10 sec.

4

Strike

Unlocks Door

10 sec.

Sample: EL25 Controlling Single Family Residence (Page 18)
Device

Location

Main Keypad and
(REX) Exit Request

Driveway

Wiegand Card Reader
CCTV

Pedestrian Gate
In EL25

Door No.

Relay Function

Relay Activation Time (Seconds)

1

Strike

Opens Vehicular Gate

10 sec.

2

Control

Turns on Security Light

10 sec.

Door 2

3

Strike

Unlocks Pedestrian Gate

10 sec.

Door 3

4

CCTV

Activates Camera

10 sec.

Relay Function

Relay Activation Time (Seconds)

Unlocks Door
Unlocks Door

10 sec.
10 sec.

Door 1

Relay Relay Mode

Sample: EL25 Controlling Multi-Resident Apartment (Page 19)
Device

Location

Door No.

Main Keypad
Transmitter and REX Exit Device

Front Door (Entrance)
Vehicular Gate

Door 1

Wiegand Card Reader
Siren

Front Door (Entrance)

Pool Gate

Door 2
Door 3
Door 4

Relay Relay Mode
1
2

Strike
Strike

3

Strike

Unlocks Door

10 sec.

4

Shunt

Bypasses/Signals Alarm

30 sec.

Page 14

EL25 SetUp “Your Settings”

EL25 SetUp “Your Settings”

Device

(See Tables below for reference)

Your System Layout

Door Stat 1
Connection

Door Sensor
and/or
Exit Device

EL25 SetUp “Your Settings”

EL25 SetUp “Your Settings”

How your system has been wired is an important part of programming it. Write down your
configuration. To help visualize it, draw a map of it below. If you're unsure of your setup, consult
your dealer/installer for more information.

External Access Control Device(s) connected to aux board(s)
Device 0 (Default Internal Keypad)
Device 1

Door Stat 2
Connection

Door Sensor
and/or
Exit Device

Device 2
Device 3
Device 4

Door Stat 3
Connection

Door Sensor
and/or
Exit Device

Relay Connections

Door Sensor
and/or
Exit Device

Yes
No

Postal
Lock

Yes
No

CCTV
Camera

Yes
No

Relay 1
Relay 2

Door Stat 4
Connection

Autocall
Device

Relay 3
Relay 4

Page 15

EL25 Controlling 1 Door

Relay 1 - Strike Mode
Unlocks Door for 10 sec.
Relay 2 - Shunt Mode
Bypasses/Signals Alarm
for Maglock for 40 sec.

Relay 4 - CCTV Mode
Activates Camera for
10 sec.

REX Device
(Exit)
EL25
Main Keypad
(Front Door)

Device

Location

Door No.

Main Keypad
Front Door

Door 1

(REX) Exit Request

Relay Relay Mode

Relay Function

Relay Activation Time (Seconds)

Unlocks Door
Bypasses/Signals Alarm

10 sec.
40 sec.

Alarm

Sounds a Siren

10 sec.

CCTV

Activates Camera

10 sec.

1
2

Strike
Shunt

3
4

EL25 Controlling 2 Doors and Vehicle Gate
Card Reader (Back Door)

Relay 3 - Strike Mode
Unlocks Door for 10 sec.

Relay 2 - Control Mode
Turns on Security Light
for 60 sec.

Relay 1 - Strike Mode
Unlocks Door for 10 sec.

EL25
Main Keypad
(Front Door)

Postal
Lock

Transmitter
(Gate Operator)
Device

Location

Main Keypad and Postal Lock
Security Light

Front Door

Wiegand Card Reader
Transmitter

Back Door
Gate Operator

Door No.

Relay Relay Mode

Relay 4 - Strike Mode
Opens Gate for 10 sec.

Relay Function

Relay Activation Time (Seconds)

Door 1

1
2

Strike
Control

Unlocks Door
Turns on Security light

10 sec.
60 sec.

Door 2

3

Strike

Unlocks Door

10 sec.

Door 3

4

Strike

Opens Gate

10 sec.

Page 16

EL25 SetUp “Your Settings”

EL25 SetUp “Your Settings”

Relay 3 - Alarm Mode
Sounds Siren for 10 sec.

EL25 Controlling 4 Doors

Relay 3 - Strike Mode
Unlocks Door for 10 sec.

Card Reader
(Manager's Door)

Relay 4 - Strike Mode
Unlocks Door for 10 sec.

Relay 2 - Strike Mode
Unlocks Door for 10 sec.

Wiegand Keypad (Exit)
Enter

Exit

EL25
Main Keypad
(Front Door)

Relay 1 - Strike Mode
Unlocks Door for 10 sec.

Device

Location

Door No.

Main Keypad
Wiegand Keypad

Front Door (Entrance)
Front Door (Exit)

Door 1

Wiegand Card Reader
Wiegand Card Reader

Back Door
Manager’s Door

Door 2
Door 3
Door 4

Relay Relay Mode

Relay Function

Relay Activation Time (Seconds)

1
2

Strike
Strike

Unlocks Door
Unlocks Door

10 sec.
10 sec.

3

Strike

Unlocks Door

10 sec.

4

Strike

Unlocks Door

10 sec.

Page 17

EL25 SetUp “Your Settings”

EL25 SetUp “Your Settings”

Card Reader
(Back Door)

Single Family Residence

Car Exit Sensor

Relay 3 - Unlocks
Pedestrian Gate

Relay 1 - Opens
Vehicular Gate

Gate Operator
(Vehicular Gate)

Card Reader
(Pedestrian Gate)

Relay 2 - Turns on Light

EL25 with optional CCTV
Camera is always on.

Device
Main Keypad and
(REX) Exit Request
Wiegand Card Reader
CCTV

Location
Driveway

Door No.
Door 1

Relay Relay Mode

Relay Function

Relay Activation Time (Seconds)

1

Strike

Opens Vehicular Gate

10 sec.

2

Control

Turns on Security Light

10 sec.

Pedestrian Gate

Door 2

3

Strike

Unlocks Pedestrian Gate

10 sec.

In EL25

Door 3

4

CCTV

Activates Camera

10 sec.

Page 18

EL25 SetUp “Your Settings”

EL25 SetUp “Your Settings”

This EL25 can operate the vehicular gate with an access code or by remote control. It will allow
Pedestrians entry with an Access Card. It will also open the gate automatically for exiting cars.

Multi-Resident Complex
This EL25 can control the property with a vehicular gate operator, access card or the unit's
keypad. Residents can use programmed transmitters for the parking lot, access cards for the pool
or a personal entry code for the main entrance. The main entrance is equipped with a door sensor
to alert management about inappropriate use. The exit sensor will automatically open the gate for
exiting cars.

Card Reader Relay 3
Opens Pool Gate

Card Reader
(Pool Gate)

Parking Lot

Manager's
Office
Car Exit Sensor

Relay 4 - Shunts Alarm
for Main Entrance

Gate Operator
(Vehicular Gate)

Internal Keypad Relay 1
Opens Main Entrance

EL25
(Main Entrance)

RF Receiver Relay 2
Opens Vehicular Gate

Device

Location

Door No.

Main Keypad
Transmitter and REX Exit Device

Front Door (Entrance)
Vehicular Gate

Door 1

Wiegand Card Reader
Siren

Pool Gate
Front Door (Entrance)

Door 2
Door 3
Door 4

Relay Relay Mode
1
2

Strike
Strike

Relay Function

Relay Activation Time (Seconds)

Unlocks Door
Unlocks Door

10 sec.
10 sec.

3

Strike

Unlocks Door

10 sec.

4

Shunt

Bypasses/Signals Alarm

30 sec.

Page 19

EL25 SetUp “Your Settings”

EL25 SetUp “Your Settings”

Pool

Entry Codes
When adding entry codes, note the following:
Each assigned Entry Code must be entered with the set amount of allowable digits (3-9). For example, if
you assign “4578” as a resident's Entry Code, but the system is set for 5 digits, the visitor will have to enter
“04578” to enter the building.

50

Add an Entry Code ONLY. For adding or editing full function Entry Codes (i.e., codes with additional options
such as use schedules, door assignments, etc.).
1 Press

Then

2 Enter Entry Code (3-9 digits). Then (#)

Note: Factory Setting for Entry Code Length is 4 digits
See “Entry Code Length” above.

Example:
1

2

Adds Entry Code “5400”.

Note: A basic Entry Code will be active with the current date, time and never deactivates, unlock all controlled
doors, with no time constraint (i.e., can be used 24 hours a day, 7 days a week).

If you make an error during an entry, press the asterisk key ( ) to begin again.

*

Access Cards
When adding cards, note the following:
• If you don't add a facility code or card type, the system will assign the default. The allowable facility code
range is 0-255 for 26-bit cards and 0-63 for 30-bit cards.

• When entering cards with facility codes:
–
Enter the facility codes individually when adding cards OR
– Enter a default facility code. If you don't, the card will be assigned the default facility code.

Add a Basic Card:

80

This programming step allows you to add a card using the card's number. For adding or editing full function
cards (i.e., cards with additional options such as use schedules, door assignments, etc.).
Then

1 Press

Required Step
Optional Step,
Press (#) to Skip.

2 Enter Card Number (1-65534). Then (#)
3 Enter Facility Code (0-63 or 0-255, depending on the card type). Then (#)
4 Enter Card Type (26 or 30). Then (#)

Example:
1

2

3

4

Adds card with number “34432”, default Facility Code and 30-bit Card Type.

Notes: A basic card will be active with the current system time and never deactivate, unlock all doors connected
to the EL25, with no time constraint (i.e., can be used 24 hours a day, 7 days a week).
For new records, if you don't add a Facility Code or Card Type, the system will add the defined default values.

Page 20

Entry Codes / Access Cards

Entry Codes / Access Cards

Add a Basic Entry Code:

Transmitters
When adding transmitter codes, note the following:
• The label on the back of the transmitter displays the codes necessary to program the transmitter.
ID Number
Button Number

PASSPORT
SW ID SEQ FC PIN
1-3 03 00 034 12241
4 03 00 163 45009

• To activate more than one button on a transmitter, you must repeat all steps for each button. If you want to
activate four buttons of a new transmitter, you will need to perform the Program Number fourfour
times,
90
activating each button separately.

Add a Basic Transmitter:

90

Add a Basic transmitter to the system's database. A basic transmitter will be active, unlock all doors/gates
assigned to the RF module with no time constraints (i.e., can be used 24 hours a day, 7 days a week.).

1 Press

Then

4 Enter Sequence Code (0-2). Then (#)

2 Enter Transmitter Number (1-65534). Then (#)

5 Enter ID Number (0-26). Then (#)

3 Enter Facility Code (0-255). Then (#)

6 Enter Button Number (1-4). Then (#)
6
1
Important: Allthroughepsmust
be
performed for EACH Transmitter
assigned.

Example:

1

2

3

4

5

6

Activates transmitter number “34430”, facility code “3”, sequence code “2”, ID number “4” and
button “1”.

If you make an error during an entry, press the asterisk key ( ) to begin again.

*

Page 21

Transmitters

Transmitters

Codes for Buttons 1-3
Codes for Button 4

Sequence Code
Facility Code
Transmitter Number

A

Access Device (RF Receiver, Card Reader, or Keypad) - A device that reads transmitter, card or entry codes, allowing
the system to allow or reject entry based on the code's validity.
Access Codes - Codes that enable visitors and residents to enter a building through a controlled area. Access codes
include directory codes, entry codes, cards and transmitters. An access code is associated with a specific access device.
Directory codes are associated with the EL25 unit; entry codes with the unit keypad; cards with card readers; and
transmitters with radio frequency (RF) receivers.
Alarms - The EL25 unit may be configured to trigger an alarm (e.g., Activate a siren and/or a warning light, etc.) when
an alarm condition occurs. These conditions include a door held open too long, a door forced open, or keypad errors
that exceed the maximum allowed.
Anti-Passback - The Anti-Passback feature prevents unauthorized use of entry codes, cards, and transmitters. When
anti-passback is enabled, an access code will be temporarily disabled after each use, thereby prohibiting people from
“passing back” their access code, card, or transmitter to unauthorized people.

B

Button Number - Refers to the number assigned to each button on a multi-button transmitter. Up to 4 buttons per
remote.

C

Call Forwarding - The EL25 can be programmed to “forward” a visitor call to another location when residents are away.
This feature also allows you to grant access to a visitor from a remote location.
Call Forward Control Setting - When enabled, allows the unit to use Call Forwarding with schedules.
Call Waiting (NPBI / Single Family Residence) - If the resident's phone is in use when the visitor presses the “Call”
key, they will hear 2 short tones to signal that a visitor is attempting to call. They may simply switch over to the call
from the visitor, let him/her in, and go back to the original call. This feature is only available for a single-family residence
or a manager's phone sharing a phone line with the EL25.
Card Type - 26-Bit standard or 30-Bit.
Credential - A card, PIN or Biometric .

D

Direct Commands (NPBI / Single Family Residence) - You may send a direct command from your residence phone to
activate one of four relays (i.e., to open a door). This feature is only available for a single-family residence or a
manager's phone sharing a phone line with the EL25 unit.
Directory Code - Unique 1-2 digit codes that dial a corresponding telephone number in the building. The unit will dial
the phone number assigned to the code.
Do Not Disturb (DnD) - The EL25 has the ability to block visitor calls during specific times. Using schedules, the feature
activates and deactivates automatically.
DnD Control Setting - When enabled the unit will enforce DnD schedule, if disabled the unit will ignore DnD schedule.
DTMF phone - Dual Tone Multi Frequency (Touch-Tone Phone).

E

Entry Card - A resident presents an entry card to a card reader to gain entry into a controlled area. A card's PIN, or
“Personal Identification Number”, is a part of the encoded information that makes a card unique.
Entry Code - Programmable, numeric codes (3-9 digits in length) that allow entry or exit through a gate/door. Residents
enter their assigned entry code onto the unit's keypad to prompt the system to grant access.

F

Facility Code - A code that allows access cards/transmitters to be associated with a facility or complex. This allows you
to manage more than one complex. You may also assign a default facility code if a group of access cards/transmitters
will share the same code.

Continued on next page

Page 22

Glossary

Glossary

Glossary

Glossary
Gate or Door - Used synonymously throughout the manual, these terms refer to controllable entry/exit areas of the

G complex, normally a gate or door.

H Holiday Schedules - Holiday schedules will modify fixed schedules for selected holiday dates.
I

ID Number - One part of the number sequence on a transmitter.

M Manager - This person manages a complex and/or programs the system.
NPBI system - No Phone Bill Interface. Uses main phone line like a intercom system between EL25 and the resident

P

PBX - A PBX telephone system (Automated) needs to dial a specific number (0-9) then pause briefly, allowing the PBX
system to connect to an outside phone line, then the phone number can be dialed.
PIN Code - Personal Identification Number predefined for a HID card or Transmitter.
Programming Number - This is a number that the EL25 uses to program a function. Each number performs a specific
task.

R

Radio Frequency (RF) and Wiegand Module - Each RF module is an RF receiver that is compatible with Chamberlain
Passport™ transmitters. Each Wiegand module provides Wiegand inputs for two card readers or other compatible
devices.
Relay - A device that responds to an electric current by activating other devices, allowing the system, for example, to
lock or unlock a door/gate, shunt (i.e., reroute) alarm contacts, signal an alarm, or turn on a camera that transmits its
images to a closed circuited television (CCTV).
Resident - Person occupying and/or who has entry access to the building or complex that is controlled by a EL25 unit.
The term “resident” as used in the context of the manual refers to such persons as homeowners, tenants of an
apartment complex, etc.
Schedules - You can restrict the use of access codes/transmitters by setting limits on the days and times they may be

S used. Schedules may also be assigned to doors to restrict residents from gaining access to the building.
Sequence Code - One part of the number sequence of a transmitter.

T

Telco Mode - Uses the main telephone line for the unit's communications to a house or complex.
Transaction - System activity logged and recorded into the EL25's memory. Such activity includes visitor to resident
directory calls and transmitter, card, or code activity.
Transmitter - A resident-activated clicker device used to gain entry into a controlled area.
Unit - The unit houses the EL25's core components. All system programming will be routed to the EL25.

U Unit ID Code - Identification number for each unit in a multiple unit setup sharing the same phone line.
Versa XS - The software to program the EL25 with.

V Visitor - A visitor can communicate with residents via the EL25. A resident can grant or deny a visitor access with their
touch tone phone.

Page 23

Glossary

Glossary

N phone. No monthly or per call telephone charges.

Appendix
Access Cards

Page 20

Direct Commands

Page 8
Page 20

Programming
– Enter Program Mode
– Exit Program Mode
– Multiple Units
– Single Unit
Quick Reference Guide
System
– Clock
– Feedback/Responses
– Password
– Unit’s ID

Page 7
Page 7
Page 9
Page 6
Pages 1-5

Page 10
Page 8
Page 10
Page 10

Setup
– Doors
– Relays

Pages 12-19
Pages 11-13

Transmitters

Page 21

Glossary

Pages 22-23

Page 24

Appendix

Appendix

Entry Codes

®

™
845 Larch Avenue
Elmhurst, Illinois 60125-1196

114A3042

© 2005 The Chamberlain Group, Inc.
All Rights Reserved



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Page Count                      : 26
Page Mode                       : UseOutlines
Page Layout                     : SinglePage
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:df812a96-b276-11d9-9f47-003065c8be78
Producer                        : Acrobat Distiller 6.0.1 for Macintosh
Modify Date                     : 2005:04:21 08:06:00-07:00
Creator Tool                    : QuarkXPress: pictwpstops filter 1.0
Create Date                     : 2005:01:06 15:25:01-08:00
Metadata Date                   : 2005:04:21 08:06:00-07:00
Document ID                     : uuid:4bde5857-603a-11d9-a337-000a9567ae2a
Format                          : application/pdf
Creator                         : The Chamberlain Group, Inc.
Title                           : EL25 Keypad Quickstart
Author                          : The Chamberlain Group, Inc.
EXIF Metadata provided by EXIF.tools

Navigation menu