Champion Industries Euccw Series Specification Sheet
2015-08-26
: Champion-Industries Champion-Industries-Euccw-Series-Specification-Sheet-802761 champion-industries-euccw-series-specification-sheet-802761 champion-industries pdf
Open the PDF directly: View PDF .
Page Count: 6
Download | |
Open PDF In Browser | View PDF |
STANDARD FEATURES • • • • • • • • • • • • • • • • • • • • • • ENERGY STAR® Qualified (EUCCW6 & EUCCW8 only) Exclusive Dual Rinse Technology All-purpose 29" wide peg belt Dish capacities up to 19,140 dishes per hour (NSF Certified) Automatic tank fill Chemical dispensing equipment connection provisions Choice of tank heat: electric, steam coils or direct steam injectors Common hot water connection Common drain connection Common electric connection (separate connection required for optional electric booster and blower-dryer) One piece stainless steel wash/rinse manifold system, easy to remove Door safety switch Electric eye energy sentinel (idle pump shut-off) Easy-to-reach top-mounted controls Heavy-gauge stainless construction Low-water tank heat protection Push-button start-stop station – load end Recirculating flushing nozzles – load end with prewash Rinse saver device Conveyor shut-off shelf – unload end Stainless steel enclosure panels – front & ends Vent fan control connection provided OPTIONAL WORLD CLASS FEATURES • Heat Recovery – redirects lost steam to heat using less energy EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine Photo is for general visual representation only. Please refer to specifications for the latest detailed product information. SPECIFIER STATEMENT Specified unit will be Champion model EUCCW4, EUCCW6 or EUCCW8 upright 29" conveyor water saver dishwashing machine. Features automatic tank fill, chemical dispensing connection provisions, common water, drain and electrical connections, door safety switch, low water tank heat protection, rinse saver. 1 year parts and labor warranty. CH104 The DualRinse feature offers the Lowest Water/Utility/Chemical Consumption as low as 57 GPH usage while circulating as much as 400 gallons of water for Consistently Good Results 2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 Tel: 905-562-4195 Fax: 905/562-4618 Champion Industries, Inc. 3765 Champion Boulevard, Winston-Salem, NC 27105 Tel: 336/661-1556 Fax: 336/661-1979 www.championindustries.com (pdf) 8/15 Champion, an Ali Group Company EUCCW SERIES UPRIGHT CONVEYORS Project Item No. Quantity EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine MODULAR SECTIONS: Right to Left Operation Dimensions shown in inches and [millimeters] EUCCW4 5'-8" [1727] 9'-4" CL-CL [2845] 4B 1 2'-1" [635] 1'-10" [559] 4A 3 6" [152] 18-5/8" [473] 39" [991] CL CL 12" [305] 29" [737] Clearance Plumbing Clearance 37-1/4" [946] 6-1/4" [159] 31-1/2" [800] 4' [1219] 2 Overall Length “C” Minimum For Screen Removal “B” Unload “A” Load 4' [1219] Wash 2'-6" [762] 2' [610] 4" [102] 4B 1 4" [102] 4A 5-1/2" [140] 7" [178] 12" [305] Plumbing Clearance 7" [178] 19" [483] 100" [2540] Door Clear Removal Dual Rinse 1/2 HP Wash Prewash 38" [965] 36" [914] 0.2 HP 10-1/2" [266] 1 3 HP HP TABLE A - Machine Connection Machine Only - Electric Heat Elec. Specs. Rated Amps Minimum Supply Ckt. Conductor Ampacity 208/60/3 240/60/3 480/60/3 171 149 74 200 175 90 Maximum Overcurrent Protective Device Elec. Specs. 200 175 90 208/60/3 240/60/3 480/60/3 Elec. Specs. Rated Amps 208/60/3 240/60/3 480/60/3 28 36 12 35 30 15 Start/Stop Notes: Machine-steam TABLE B - Booster Connection 40°F/22°C Rise – 10kW Electric Built-in Booster Minimum Supply Ckt. Conductor Ampacity 62" [1575] Machine Height 3 1-5/8" [41] 2 Rated Amps Minimum Supply Ckt. Conductor Ampacity Maximum Overcurrent Protective Device 21 18 10 25 25 15 25 25 15 • • • • • 70°F/39°C Rise - 18kW Electric Built-in Booster Maximum Overcurrent Protective Device Elec. Specs. 35 30 15 208/60/3 240/60/3 480/60/3 95" [2413] Doors Up Rated Amps Minimum Supply Ckt. Conductor Ampacity Maximum Overcurrent Protective Device 50 43 22 70 60 30 70 60 30 • • • • Load Section (A) Standard 5', contains 30" Prewash Prewash also available in a 48" HD section Non-standard load section available in 12" increments Minimum load length 5' (includes 30" prewash) Unload Section (B) Standard 5 ft contains 24" Aux. Rinse and 36" belt, available in 12" increments Built in electric booster requires a 5' minimum unload Built in steam booster requires a minimum 6' unload Blow dryer section adds 4' to overall length of machine Contact Factory for additional voltages. Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice. Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618 EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine MODULAR SECTIONS: Right to Left Operation Dimensions shown in inches and [millimeters] EUCCW6 5'-8" [1727] 11'-4" CL-CL [3454] 4B 2'-1" [635] 1'-10" [559] 18-5/8" [473] 39" [991] 1 4A 3 6" [152] Plumbing Clearance CL CL 29" Clear 37-1/4" [737] [946] 12" [305] 6-1/4" [159] 2 31-1/2" [800] 4' [1219] Overall Length “C” Minimum For Screen Removal “B” Unload 4B 6' [1829] Wash/Rinse 4" [102] 2' [610] 3' [914] “A” Load 3' [914] 5-1/2" 1 [140] 2'-6" [762] 4" [102] 7" [178] 4A 12" [305] Plumbing Clearance 7" [178] 19" [483] 100" [2540] Door Clear Removal Dual Rinse 1/2 HP Power Rinse Wash Prewash 38" [965] 36" [914] 0.2 HP 3 3 1 HP HP 10-1/2" 2 [266] 1-5/8" [41] TABLE A - Machine Connection Machine Only - Electric Heat Elec. Specs. Rated Amps Minimum Supply Ckt. Conductor Ampacity 208/60/3 240/60/3 480/60/3 183 158 80 250 200 100 Maximum Overcurrent Protective Device Elec. Specs. 250 200 100 208/60/3 240/60/3 480/60/3 Elec. Specs. Rated Amps 208/60/3 240/60/3 480/60/3 28 36 12 35 30 15 Rated Amps Minimum Supply Ckt. Conductor Ampacity Maximum Overcurrent Protective Device 29 26 14 40 35 20 40 35 20 • • • • • 70°F/39°C Rise - 18kW Electric Built-in Booster Maximum Overcurrent Protective Device Elec. Specs. 35 30 15 208/60/3 240/60/3 480/60/3 62" [1575] Machine Height Start/Stop Notes: Machine-steam TABLE B - Booster Connection 40°F/22°C Rise – 10kW Electric Built-in Booster Minimum Supply Ckt. Conductor Ampacity 3 HP 95" [2413] Doors Up Rated Amps Minimum Supply Ckt. Conductor Ampacity Maximum Overcurrent Protective Device 50 43 22 70 60 30 70 60 30 • • • • Load Section (A) Standard 5', contains 30" Prewash Prewash also available in a 48" HD section Non-standard load section available in 12" increments Minimum load length 5' (includes 30" prewash) Unload Section (B) Standard 5 ft contains 24" Aux. Rinse and 36" belt, available in 12" increments Built in electric booster requires a 5' minimum unload Built in steam booster requires a minimum 6' unload Blow dryer section adds 4' to overall length of machine Contact Factory for additional voltages. Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice. Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618 EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine MODULAR SECTIONS: Right to Left Operation Dimensions shown in inches and [millimeters] EUCCW8 4B 5'-8" [1727] 13'-4" CL-CL [4064] 1 2'-1" [635] 1'-10" [559] 18-5/8" [473] 4A 3 6" [152] CL CL 39" [991] 12" [305] Plumbing Clearance 29" [737] 37-1/4" [946] Clear 6-1/4" [159] 4' [1219] 2 31-1/2" [800] Overall Length “C” Minimum For Screen Removal 4" [102] 4B 7" [178] 2' [610] 4' [1219] 36" [914] 0.2 HP 10-1/2" [266] 4' [1219] 1 5-1/2"[140] 2'-6" [762] [102] 4" 4A 7" [178] Wash Power Rinse Dual Rinse 1/2 HP “A” Load 8' [2438] Wash/Rinse “B” Unload 3 19" [483] 100" [2540] Clear Door Removal Prewash 3 HP 1 HP 3 HP 1-5/8" [41] 2 TABLE A - Machine Connection Machine Only - Electric Heat Elec. Specs. Rated Amps Minimum Supply Ckt. Conductor Ampacity 208/60/3 240/60/3 480/60/3 183 158 80 250 200 100 Elec. Specs. 250 200 100 208/60/3 240/60/3 480/60/3 TABLE B - Booster Connection 40°F/22°C Rise – 18kW Electric Built-in Booster Elec. Specs. Rated Amps Minimum Supply Ckt. Conductor Ampacity 208/60/3 240/60/3 480/60/3 50 43 22 70 60 30 Maximum Overcurrent Protective Device 70 60 30 Rated Amps Minimum Supply Ckt. Conductor Ampacity Maximum Overcurrent Protective Device 29 26 14 40 35 20 40 35 20 • • • • • 70°F/39°C Rise - 32kW Electric Built-in Booster Elec. Specs. Rated Amps 95" [2413] Doors Up 38" [965] 62" [1575] Machine Height Start/Stop Notes: Machine-steam Maximum Overcurrent Protective Device 12" [305] Plumbing Clearance Minimum Supply Ckt. Conductor Ampacity 208/60/3 89 125 240/60/3 77 100 480/60/3 39 50 Contact Factory for additional voltages. Maximum Overcurrent Protective Device 125 100 50 • • • • Load Section (A) Standard 5', contains 30" Prewash Prewash also available in a 48" HD section Non-standard load section available in 12" increments Minimum load length 5' (includes 30" prewash) Unload Section (B) Standard 5 ft contains 24" Aux. Rinse and 36" belt, available in 12" increments Built in electric booster requires a 5' minimum unload Built in steam booster requires a minimum 6' unload Blow dryer section adds 4' to overall length of machine Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice. Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618 EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine Shipping weight crated: 150 lbs./ft.[68kg./m.] Height with doors up: 95" Height to remove doors: 100" Utilities EUCCW4 1 Electrical Connection A Machine connection (see table A) B Booster connection (see table A) SPECIFICATIONS Capacities EUCCW4 EUCCW6 EUCCW8 Dishes per hr. (NSF rated) 9,965 Conveyor speed (ft./min.) 6.3 Motor horsepower 2 Hot Water Drive Prewash 30" [762] Prewash 48" [1219] Wash Power Rinse* Auxiliary Rinse 1/2 Hp 1 Hp 3 Hp 3 Hp N/A 1/5 Hp Gal. per hr. (max. use) Temperatures °F 19,140 12.1 Wash (min.) Power Rinse (min.)* Auxiliary Rinse (min.) Final rinse (min.) 1/2 Hp 1 Hp 3 Hp 3 Hp 3 Hp 1/5 Hp 58 160 N/A 165 180 1/2 Hp 1 Hp 3 Hp 3 Hp 3 Hp 1/5 Hp 57 150 160 165 180 158 150 160 165 180 Heating Tank heat Steam Electric Wash tank 125 lbs./hr. 25 kW Wash tank (EUCCW4) 225 lbs./hr. 45 kW Rinse tank * 100 lbs./hr. 20 kW Auxiliary rinse 50 lbs./hr. 10 kW Electric booster 10 10 18 (kW required for 40°F rise) Electric booster 18 18 32 (kW required for 70°F rise) Steam booster 50 50 90 (lbs./hr. required for 40°F rise) Steam booster 90 90 150 (lbs./hr. required for 70°F rise) 3 Drain 2" NPT connection, 62 gpm max flow rate 4 Vents Water consumption 13,445 8.5 3/4" NPT 180°F hot water connection. (For machine without built-in booster) Venting Minimum CFM, load end Minimum CFM, unload end *EUCCW4 has no power rinse tank 300 800 Booster connections may vary. Contact the Factory. Standard Voltages (Specify choice): 208/60/3, 240/60/3, and 480/60/3. Available in 3-phase only. For non-standard 3-phase voltages, contact the Factory. Plumbing Notes Because of the variation in house-supplied water pressure, a water pressure regulating valve (PRV) is needed (water PRV is standard with a booster). Steam PRV’s may be required for pressure higher than 30 psi. The PRVs can either be purchased from Champion or obtained locally. A Load end: 300 CFM 1/4" S.P. B Unload end: 800 CFM 1/4" S.P. With blower-dryer, increase room ventilation by 600 CFM. Utilities EUCCW6 1 Electrical Connection Contact factory for specific machine electrical requirements NOTE: Electric booster connection – contact Factory 2 Hot Water 3/4" NPT 180°F hot water connection. (For machine without built-in booster) 3 Drain 2" NPT connection, 62 gpm max flow rate 4 Vents A Load end: 300 CFM 1/4" S.P. B Unload end: 800 CFM 1/4" S.P. With blower-dryer, increase room ventilation by 600 CFM. Utilities EUCCW8 1 Electrical Connection Contact factory for specific machine electrical requirements NOTE: Electric booster connection – contact Factory 2 Hot Water 3/4" NPT 180°F hot water connection. (For machine without built-in booster) 3 Drain 2" NPT connection, 62 gpm max flow rate 4 Vents A Load end: 300 CFM 1/4" S.P. B Unload end: 800 CFM 1/4" S.P. With blower-dryer, increase room ventilation by 600 CFM. Warning Plumbing and electrical connections should be made by qualified personnel who will observe all the applicable plumbing, sanitary, safety codes and the National Electrical Code. Note Water Hammer Arrestor (meeting ASSE-1010 standard or equivalent) to be supplied (by others) in common water supply line at service connection. Venting Notes Fabricated duct size: 3-7/8" x 23-7/8" (outside dimensions) Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice. Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618 Champion, an Ali Group Company EUCCW SERIES UPRIGHT CONVEYOR EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine Control Panel OPTIONS & ACCESSORIES □□ Tank heat; choices of electric, steam coil or Digital Gauges Heat Recovery – Redirects lost steam to heat using less energy. steam injectors 110 Heated °F water travels back to booster □□ Booster Heaters – stainless steel (completely inter-plumbed, controls are inter-wired) □□ Electric: (40°F rise or 70°F rise) □□ Steam: (40°F or 70°F rise) □□ 48" Blower Dryer, electric or steam (add 4' to overall length) □□ Belts: standard peg belt, flat belt, thermal tray belt, silverware belt, belts with upper cross rods, and other select combination belts Water leaves booster at 180°F+ and travels to final rinse arms Booster 60°F incoming water to machine. □□ Start/Stop station, unload end □□ Back panels, stainless steel □□ Cold water thermostat (for pre-wash) □□ External scrap bucket on 48" pre-wash (standard on 30" pre-wash) □□ External scrap bucket on wash tank □□ Insulated hoods, lower panels □□ Motor pumps, 2 or 3 Hp optional in lieu of 1 Hp on pre-wash □□ Bumper rail, machine mounted □□ Steam pressure regulating valve (unmounted □□ Drain water tempering kit (mounted) □□ Insulated hinged door □□ Shock arrestor (water) □□ Drain interlocks □□ Heat Recovery Unit redirects lost steam to heat using less energy Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice. Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2015:08:10 14:25:29-04:00 Creator : Adobe InDesign CS6 (Macintosh) Modify Date : 2015:08:10 14:30:30-04:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Instance ID : uuid:20d3945e-a79a-49ba-bbc2-2c37b8e02f53 Original Document ID : adobe:docid:indd:c4aaa224-9dad-11dd-ac7e-b54cc0ce0783 Document ID : xmp.id:F0E51D9663226811822AF493D6651AF7 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:EFE51D9663226811822AF493D6651AF7 Derived From Document ID : xmp.did:EFE51D9663226811822AF493D6651AF7 Derived From Original Document ID: adobe:docid:indd:c4aaa224-9dad-11dd-ac7e-b54cc0ce0783 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2015:08:10 14:25:29-04:00 Metadata Date : 2015:08:10 14:30:30-04:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 6EXIF Metadata provided by EXIF.tools