Champion Industries Euccw Series Specification Sheet

2015-08-26

: Champion-Industries Champion-Industries-Euccw-Series-Specification-Sheet-802761 champion-industries-euccw-series-specification-sheet-802761 champion-industries pdf

Open the PDF directly: View PDF PDF.
Page Count: 6

DownloadChampion-Industries Champion-Industries-Euccw-Series-Specification-Sheet-  Champion-industries-euccw-series-specification-sheet
Open PDF In BrowserView PDF
STANDARD FEATURES
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

ENERGY STAR® Qualified (EUCCW6 & EUCCW8 only)
Exclusive Dual Rinse Technology
All-purpose 29" wide peg belt
Dish capacities up to 19,140 dishes per hour (NSF Certified)
Automatic tank fill
Chemical dispensing equipment
connection provisions
Choice of tank heat: electric, steam
coils or direct steam injectors
Common hot water connection
Common drain connection
Common electric connection (separate
connection required for optional electric
booster and blower-dryer)
One piece stainless steel wash/rinse
manifold system, easy to remove
Door safety switch
Electric eye energy sentinel (idle pump shut-off)
Easy-to-reach top-mounted controls
Heavy-gauge stainless construction
Low-water tank heat protection
Push-button start-stop station – load end
Recirculating flushing nozzles –
load end with prewash
Rinse saver device
Conveyor shut-off shelf – unload end
Stainless steel enclosure panels – front & ends
Vent fan control connection provided

OPTIONAL WORLD CLASS FEATURES
•	 Heat Recovery – redirects lost steam to heat
using less energy

EUCCW SERIES

Upright 29" Conveyor
Dual Rinse Dishwashing Machine

Photo is for general visual
representation only. Please refer
to specifications for the latest
detailed product information.

SPECIFIER STATEMENT
Specified unit will be Champion model EUCCW4,
EUCCW6 or EUCCW8 upright 29" conveyor water
saver dishwashing machine.
Features automatic tank fill, chemical dispensing
connection provisions, common water, drain and
electrical connections, door safety switch, low water
tank heat protection, rinse saver.
1 year parts and labor warranty.

CH104

The DualRinse feature offers the
Lowest Water/Utility/Chemical Consumption
as low as 57 GPH usage while circulating
as much as 400 gallons of water for
Consistently Good Results      

2674 N. Service Road,
Jordan Station, Ontario, Canada L0R 1S0
Tel: 905-562-4195 Fax: 905/562-4618

Champion Industries, Inc.
3765 Champion Boulevard, Winston-Salem, NC 27105 Tel:
336/661-1556 Fax: 336/661-1979
www.championindustries.com

(pdf) 8/15
Champion, an Ali Group Company

EUCCW SERIES UPRIGHT CONVEYORS

Project
Item No.
Quantity

EUCCW SERIES
Upright 29" Conveyor
Dual Rinse
Dishwashing Machine
MODULAR SECTIONS: Right to Left Operation
Dimensions shown in inches and [millimeters]

EUCCW4

5'-8"
[1727]

9'-4" CL-CL
[2845]

4B

1

2'-1"
[635]
1'-10"
[559]

4A

3
6" [152]

18-5/8"
[473]
39" [991]

CL

CL

12" [305]

29" [737]
Clearance

Plumbing
Clearance

37-1/4"
[946]

6-1/4" [159]
31-1/2"
[800]

4' [1219]

2

Overall Length “C”

Minimum For Screen Removal
“B”
Unload

“A”
Load

4' [1219]
Wash
2'-6"
[762]

2'
[610]

4" [102]
4B

1

4" [102]
4A

5-1/2"
[140]

7" [178]

12" [305]
Plumbing
Clearance

7" [178]

19" [483] 100" [2540]
Door
Clear
Removal
Dual
Rinse

1/2 HP

Wash

Prewash

38"
[965]

36" [914]
0.2
HP

10-1/2" [266]

1

3

HP

HP

TABLE A - Machine Connection
Machine Only - Electric Heat
Elec.
Specs.

Rated
Amps

Minimum
Supply Ckt.
Conductor
Ampacity

208/60/3
240/60/3
480/60/3

171
149
74

200
175
90

Maximum
Overcurrent
Protective
Device

Elec.
Specs.

200
175
90

208/60/3
240/60/3
480/60/3

Elec.
Specs.

Rated
Amps

208/60/3
240/60/3
480/60/3

28
36
12

35
30
15

Start/Stop

Notes:

Machine-steam

TABLE B - Booster Connection
40°F/22°C Rise – 10kW Electric Built-in Booster
Minimum
Supply Ckt.
Conductor
Ampacity

62" [1575]
Machine Height

3
1-5/8" [41]

2

Rated
Amps

Minimum
Supply Ckt.
Conductor
Ampacity

Maximum
Overcurrent
Protective
Device

21
18
10

25
25
15

25
25
15

•	
•	
•	
•	
•	

70°F/39°C Rise - 18kW Electric Built-in Booster

Maximum
Overcurrent
Protective
Device

Elec.
Specs.

35
30
15

208/60/3
240/60/3
480/60/3

95" [2413]
Doors Up

Rated
Amps

Minimum
Supply Ckt.
Conductor
Ampacity

Maximum
Overcurrent
Protective
Device

50
43
22

70
60
30

70
60
30

•	
•	
•	
•	

Load Section (A) Standard 5',
contains 30" Prewash
Prewash also available in a
48" HD section
Non-standard load section
available in 12" increments
Minimum load length 5'
(includes 30" prewash)
Unload Section (B) Standard
5 ft contains 24" Aux.
Rinse and 36" belt, available
in 12" increments	
Built in electric booster requires
a 5' minimum unload
Built in steam booster requires
a minimum 6' unload
Blow dryer section adds 4' to
overall length of machine	

Contact Factory for additional voltages.
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618

EUCCW SERIES
Upright 29" Conveyor
Dual Rinse
Dishwashing Machine
MODULAR SECTIONS: Right to Left Operation
Dimensions shown in inches and [millimeters]

EUCCW6

5'-8"
[1727]

11'-4" CL-CL
[3454]

4B

2'-1"
[635]
1'-10"
[559]

18-5/8"
[473]
39" [991]

1
4A
3
6" [152]

Plumbing
Clearance

CL

CL

29" Clear 37-1/4"
[737]
[946]

12" [305]

6-1/4" [159]
2

31-1/2"
[800]

4'
[1219]

Overall Length “C”
Minimum For Screen Removal

“B”
Unload

4B

6' [1829]
Wash/Rinse
4"
[102]

2'
[610]

3'
[914]

“A”
Load
3'
[914]
5-1/2"
1 [140]

2'-6"
[762]

4"
[102]

7" [178]

4A

12" [305]
Plumbing
Clearance

7" [178]

19"
[483] 100" [2540]
Door
Clear
Removal
Dual
Rinse

1/2 HP

Power
Rinse

Wash

Prewash

38"
[965]

36" [914]
0.2
HP

3

3

1

HP

HP

10-1/2" 2
[266]

1-5/8"
[41]

TABLE A - Machine Connection
Machine Only - Electric Heat
Elec.
Specs.

Rated
Amps

Minimum
Supply Ckt.
Conductor
Ampacity

208/60/3
240/60/3
480/60/3

183
158
80

250
200
100

Maximum
Overcurrent
Protective
Device

Elec.
Specs.

250
200
100

208/60/3
240/60/3
480/60/3

Elec.
Specs.

Rated
Amps

208/60/3
240/60/3
480/60/3

28
36
12

35
30
15

Rated
Amps

Minimum
Supply Ckt.
Conductor
Ampacity

Maximum
Overcurrent
Protective
Device

29
26
14

40
35
20

40
35
20

•	
•	
•	
•	
•	

70°F/39°C Rise - 18kW Electric Built-in Booster

Maximum
Overcurrent
Protective
Device

Elec.
Specs.

35
30
15

208/60/3
240/60/3
480/60/3

62" [1575]
Machine
Height

Start/Stop

Notes:

Machine-steam

TABLE B - Booster Connection
40°F/22°C Rise – 10kW Electric Built-in Booster
Minimum
Supply Ckt.
Conductor
Ampacity

3

HP

95" [2413]
Doors Up

Rated
Amps

Minimum
Supply Ckt.
Conductor
Ampacity

Maximum
Overcurrent
Protective
Device

50
43
22

70
60
30

70
60
30

•	
•	
•	
•	

Load Section (A) Standard 5',
contains 30" Prewash
Prewash also available in a
48" HD section
Non-standard load section
available in 12" increments
Minimum load length 5'
(includes 30" prewash)
Unload Section (B) Standard
5 ft contains 24" Aux.
Rinse and 36" belt, available
in 12" increments	
Built in electric booster requires
a 5' minimum unload
Built in steam booster requires
a minimum 6' unload
Blow dryer section adds 4' to
overall length of machine	

Contact Factory for additional voltages.
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618

EUCCW SERIES
Upright 29" Conveyor
Dual Rinse
Dishwashing Machine
MODULAR SECTIONS: Right to Left Operation
Dimensions shown in inches and [millimeters]

EUCCW8
4B

5'-8"
[1727]

13'-4" CL-CL
[4064]

1
2'-1"
[635]
1'-10"
[559]

18-5/8"
[473]

4A
3
6" [152]
CL

CL

39" [991]

12" [305]

Plumbing
Clearance

29" [737] 37-1/4"
[946]
Clear

6-1/4" [159]
4' [1219]

2

31-1/2"
[800]

Overall Length “C”

Minimum For Screen Removal

4" [102]
4B
7" [178]

2'
[610]

4'
[1219]

36" [914]

0.2
HP

10-1/2" [266]

4'
[1219]
1 5-1/2"[140]

2'-6"
[762]

[102]
4" 4A
7" [178]

Wash

Power
Rinse

Dual
Rinse

1/2 HP

“A”
Load

8' [2438]
Wash/Rinse

“B”
Unload

3

19" [483] 100" [2540]
Clear
Door
Removal

Prewash

3

HP

1

HP

3

HP

1-5/8"
[41]

2

TABLE A - Machine Connection
Machine Only - Electric Heat
Elec.
Specs.

Rated
Amps

Minimum
Supply Ckt.
Conductor
Ampacity

208/60/3
240/60/3
480/60/3

183
158
80

250
200
100

Elec.
Specs.

250
200
100

208/60/3
240/60/3
480/60/3

TABLE B - Booster Connection
40°F/22°C Rise – 18kW Electric Built-in Booster
Elec.
Specs.

Rated
Amps

Minimum
Supply Ckt.
Conductor
Ampacity

208/60/3
240/60/3
480/60/3

50
43
22

70
60
30

Maximum
Overcurrent
Protective
Device

70
60
30

Rated
Amps

Minimum
Supply Ckt.
Conductor
Ampacity

Maximum
Overcurrent
Protective
Device

29
26
14

40
35
20

40
35
20

•	
•	
•	
•	
•	

70°F/39°C Rise - 32kW Electric Built-in Booster
Elec.
Specs.

Rated
Amps

95" [2413]
Doors Up
38"
[965] 62" [1575]
Machine
Height
Start/Stop

Notes:

Machine-steam
Maximum
Overcurrent
Protective
Device

12" [305]
Plumbing
Clearance

Minimum
Supply Ckt.
Conductor
Ampacity

208/60/3
89
125
240/60/3
77
100
480/60/3
39
50
Contact Factory for additional voltages.

Maximum
Overcurrent
Protective
Device

125
100
50

•	
•	
•	
•	

Load Section (A) Standard 5',
contains 30" Prewash
Prewash also available in a
48" HD section
Non-standard load section
available in 12" increments
Minimum load length 5'
(includes 30" prewash)
Unload Section (B) Standard
5 ft contains 24" Aux.
Rinse and 36" belt, available
in 12" increments	
Built in electric booster requires
a 5' minimum unload
Built in steam booster requires
a minimum 6' unload
Blow dryer section adds 4' to
overall length of machine	

Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618

EUCCW SERIES
Upright 29" Conveyor
Dual Rinse
Dishwashing Machine

Shipping weight crated:	 150 lbs./ft.[68kg./m.]
Height with doors up: 	
95"
Height to remove doors: 	
100"

Utilities EUCCW4

1 Electrical Connection

A Machine connection (see table A)
B Booster connection (see table A)

SPECIFICATIONS
Capacities	
	
	

EUCCW4	EUCCW6	EUCCW8

Dishes per hr. (NSF rated)	 9,965	
Conveyor speed (ft./min.)	 6.3	

Motor horsepower
	
	
	
	
	
	

2 Hot Water

Drive	
Prewash 30" [762]	
Prewash 48" [1219]	
Wash	
Power Rinse*	
Auxiliary Rinse	

1/2 Hp	
1 Hp	
3 Hp 	
3 Hp	
N/A	
1/5 Hp	

Gal. per hr. (max. use)	

Temperatures °F
	
	
	
	

19,140
12.1

Wash (min.)	
Power Rinse (min.)*	
Auxiliary Rinse (min.)	
Final rinse (min.)	

1/2 Hp	
1 Hp	
3 Hp	
3 Hp	
3 Hp	
1/5 Hp	

58	
160	
N/A	
165	
180	

1/2 Hp
1 Hp
3 Hp
3 Hp
3 Hp
1/5 Hp

57	
150	
160	
165	
180	

158
150
160
165
180

Heating

Tank heat 	
Steam	Electric
	 Wash tank	
125 lbs./hr.	 25 kW
	 Wash tank (EUCCW4)	 225 lbs./hr.	 45 kW
	 Rinse tank *	
100 lbs./hr.	 20 kW
	 Auxiliary rinse	
50 lbs./hr.	 10 kW
	 Electric booster 	
10	
10	
18	
(kW required for 40°F rise)	
	 Electric booster 	
18	
18	
32	
(kW required for 70°F rise)	
		Steam booster	
50	
50	
90	
(lbs./hr. required for 40°F rise)	
		Steam booster 	
90	
90	
150
(lbs./hr. required for 70°F rise)	
	

3 Drain

2" NPT connection, 62 gpm max flow rate

4 Vents

Water consumption
	

13,445	
8.5	

3/4" NPT 180°F hot water connection.
(For machine without built-in booster)

Venting

	 Minimum CFM, load end	
	Minimum CFM, unload end	
*EUCCW4 has no power rinse tank

300
800

Booster connections may vary. Contact the Factory.

Standard Voltages (Specify choice): 208/60/3, 240/60/3, and

480/60/3. Available in 3-phase only. For non-standard 3-phase
voltages, contact the Factory.

Plumbing Notes Because of the variation in house-supplied water

pressure, a water pressure regulating valve (PRV) is needed (water
PRV is standard with a booster). Steam PRV’s may be required for
pressure higher than 30 psi. The PRVs can either be purchased
from Champion or obtained locally.

A	 Load end: 300 CFM 1/4" S.P.
B	 Unload end: 800 CFM 1/4" S.P. With blower-dryer,
	 increase room ventilation by 600 CFM.

Utilities EUCCW6

1 Electrical Connection

Contact factory for specific machine electrical requirements 	
NOTE: Electric booster connection – contact Factory

2 Hot Water

3/4" NPT 180°F hot water connection.
(For machine without built-in booster)

3 Drain

2" NPT connection, 62 gpm max flow rate

4 Vents

A	 Load end: 300 CFM 1/4" S.P.
B	 Unload end: 800 CFM 1/4" S.P. With blower-dryer,
	 increase room ventilation by 600 CFM.

Utilities EUCCW8

1 Electrical Connection

Contact factory for specific machine electrical requirements 	
NOTE: Electric booster connection – contact Factory

2 Hot Water

3/4" NPT 180°F hot water connection.
(For machine without built-in booster)

3 Drain

2" NPT connection, 62 gpm max flow rate

4 Vents

A	 Load end: 300 CFM 1/4" S.P.
B	 Unload end: 800 CFM 1/4" S.P. With blower-dryer,
	 increase room ventilation by 600 CFM.

Warning Plumbing and electrical connections should be made by
qualified personnel who will observe all the applicable plumbing,
sanitary, safety codes and the National Electrical Code.

Note Water Hammer Arrestor (meeting ASSE-1010 standard or

equivalent) to be supplied (by others) in common water supply line
at service connection.

Venting Notes

Fabricated duct size: 3-7/8" x 23-7/8" (outside dimensions)

Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Champion, an Ali Group Company

EUCCW SERIES UPRIGHT CONVEYOR

EUCCW SERIES
Upright 29" Conveyor
Dual Rinse
Dishwashing Machine

Control Panel

OPTIONS & ACCESSORIES
□□ Tank heat; choices of electric, steam coil or

Digital Gauges

Heat Recovery –

Redirects lost steam to heat using less energy.

steam injectors

110

Heated
°F water
travels back to booster

□□ Booster Heaters – stainless steel

(completely inter-plumbed, controls are
inter-wired)
□□ Electric: (40°F rise or 70°F rise)
□□ Steam: (40°F or 70°F rise)

□□ 48" Blower Dryer, electric or steam (add 4' to

overall length)

□□ Belts: standard peg belt, flat belt, thermal tray

belt, silverware belt, belts with upper cross rods,
and other select combination belts

Water leaves
booster at

180°F+

and travels to
final rinse arms

Booster

60°F incoming water
to machine.

□□ Start/Stop station, unload end
□□ Back panels, stainless steel
□□ Cold water thermostat (for pre-wash)
□□ External scrap bucket on 48" pre-wash

(standard on 30" pre-wash)

□□ External scrap bucket on wash tank
□□ Insulated hoods, lower panels
□□ Motor pumps, 2 or 3 Hp optional in lieu of 1 Hp

on pre-wash

□□ Bumper rail, machine mounted
□□ Steam pressure regulating valve (unmounted
□□ Drain water tempering kit (mounted)
□□ Insulated hinged door

□□ Shock arrestor (water)
□□ Drain interlocks
□□ Heat Recovery Unit redirects lost steam to

heat using less energy

Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., 3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Create Date                     : 2015:08:10 14:25:29-04:00
Creator                         : Adobe InDesign CS6 (Macintosh)
Modify Date                     : 2015:08:10 14:30:30-04:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Instance ID                     : uuid:20d3945e-a79a-49ba-bbc2-2c37b8e02f53
Original Document ID            : adobe:docid:indd:c4aaa224-9dad-11dd-ac7e-b54cc0ce0783
Document ID                     : xmp.id:F0E51D9663226811822AF493D6651AF7
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:EFE51D9663226811822AF493D6651AF7
Derived From Document ID        : xmp.did:EFE51D9663226811822AF493D6651AF7
Derived From Original Document ID: adobe:docid:indd:c4aaa224-9dad-11dd-ac7e-b54cc0ce0783
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2015:08:10 14:25:29-04:00
Metadata Date                   : 2015:08:10 14:30:30-04:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 6
EXIF Metadata provided by EXIF.tools

Navigation menu