Champion Pumps Cps5 Pump Specification Sheet SCOPE

2015-08-26

: Champion-Pumps Champion-Pumps-Cps5-Pump-Specification-Sheet-802869 champion-pumps-cps5-pump-specification-sheet-802869 champion-pumps pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadChampion-Pumps Champion-Pumps-Cps5-Pump-Specification-Sheet- SCOPE  Champion-pumps-cps5-pump-specification-sheet
Open PDF In BrowserView PDF
SPECIFICATIONS
Sewage
CPS5

SCOPE: Furnish and install________ submersible non-clog sewage pump (s). Each pump shall
be capable of delivering the following performance points,__________ U.S. GPM
at____________ TDH ; ____________U.S. GPM at__________TDH; ___________U.S. GPM at
_____________TDH, with a shut off head of __________TDH (minimum) : ________U.S. GPM
at______________TDH (operating point). The pump motor speed shall be 3450RPM, 1/2 HP
(maximum) , Single Phase, 60 Hertz, ____________Volts. The pump (s) shall be manufactured
by a company regularly engaged in the manufacture and assembly of similar units for a minimum
of five (5) years. The pump (s) shall be Champion Pumps model__________________________.
PUMP DESIGN: Each pump shall be capable of handling raw, unscreened domestic sewage
consisting of water, fibrous materials, and two (3/4) inch diameter spherical solids. The pump (s)
shall be capable of handling liquids with temperatures to 140 degrees F intermittent.
PUMP CONSTRUCTION: The upper volute, seal plates and motor housing shall be constructed
of high quality ASTM A-48 class 20-30 cast iron. The pump (s) shall be painted with a water
based air dry enamel of 2.0 mil minimum thickness. All exposed hardware shall be 300 series
stainless steel. The pump construction shall contain no points of critical clearance nor require
periodic adjustment or replacement to maintain operating efficiency. Discharge connection shall
be a standard 2” inch NPT in the vertical position. All critical gaskets shall be of the point
compression o-ring type eliminating critical slip fits and the possibility of damage during service
associated with other sealing arrangements. This also ensures ease of procuring standard
industry o-ring sizes.
The impeller shall be cast iron and of the vortex design with pump out vanes on the back side.
The impeller shall be dynamically balanced to ISO G6.3 specifications.
The unit shall utilize a single mechanical Type 21 or equal shaft seal which will operate in an oil
atmosphere. The seal shall be of the inboard seal design with a secondary exlusion V seal. The
materials of construction shall be carbon for the rotating face and ceramic for the stationary face,
lapped and polished to a tolerance of one light band, 300 series stainless steel hardware, and all
elastomer parts to be of Buna-N. The seal shall be commercially available and not a propriatary
design of the manufacturer.
The pump shall be designed to be non-overloading throughout the entire pump curve. The rotor
and stator assembly shall be of the standard frame design and secured to the pump seal plate by
four threaded fasteners allowing for easy serviceability. Motor designs incorporating shrink or
press fit assembly between the stator and motor housing shall not be acceptable. The motor shall
be constructed with the windings operating in a sealed environment containing clean dielectric oil,
making it capable of operating in a totally, partially or non-submerged condition for extended
periods of time without damage due to the heat being generated. Air-filled motors shall not be
acceptable. The motor windings shall be of Class B insulation. The motor shall meet the standard
NEMA design L. The motor shaft shall be of 416 stainless steel. The lower bearing shall be of the
single ball type to accept radial and thrust loads, and the upper bearing of the single ball design,
for radial loads. Bearings shall operate in an oil bath atmosphere for superior life. Permanently
lubricated bearings are not acceptable.
Motors shall have an overload switch on the motor windings and do not require any external
protection.

SPECIFICATIONS
Sewage
CPS5

The pump shall be equipped with_______ft. of type__________power cable and connected to
the motor via molded quick disconnect socket terminals. Crimp connected cords are not
acceptable. A secondary molded rubber pressure flange shall be provided as an additional
sealing point with stainless steel back plate that provides secure compression and strain relief at
the point of cable entry. Cable entry designs utilizing compression grommets and terminal boards
to connect power cord leads with motor leads shall not be acceptable. No exposure to the motor
oil, motor chamber or motor winding leads, is acceptable when changing or servicing cord.
PUMP TEST: The pump manufacturer shall perform the following inspections and tests in
accordance with SSPMA standards before shipment from the factory:
1.
A check of the motor voltage and frequency shall be made as shown on the name plate.
2.
A motor and cable insulation test for moisture content or insulation defects shall be made
per UL/CSA criteria.
3.
The pump shall be completely submerged and run.
START-UP: The pump(s) shall be tested at start-up by a qualified representative of the
manufacturer. A start-up report as provided by the qualified representative shall be completed.
DOCUMENTATION: The manufacturer, if requested, will supply a minimum of________sets of
standard submittal data;
Standard submittal data consist of:
a.
Pump catalog data;
b.
Pump performance curve;
c.
Typical installation drawing;
d.
Installation & Operation Manuals.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Company                         : CP&S
Source Modified                 : D:20120719143130
Create Date                     : 2012:07:26 11:04:10-04:00
Creator Tool                    : Acrobat PDFMaker 7.0.7 for Word
Modify Date                     : 2012:07:26 11:04:33-04:00
Metadata Date                   : 2012:07:26 11:04:33-04:00
Document ID                     : uuid:e605e821-3cd2-48fe-8acc-2a76f568e186
Instance ID                     : uuid:71b88497-97eb-429b-8a0f-f8a2a45fe601
Version ID                      : 8
Format                          : application/pdf
Title                           : SCOPE: Furnish and install________ submersible non-clog sewage pump (s)
Creator                         : jhoman
Description                     : done 7/19
Subject                         : 
Headline                        : done 7/19
Page Count                      : 2
Page Layout                     : OneColumn
Language                        : EN-US
Author                          : jhoman
EXIF Metadata provided by EXIF.tools

Navigation menu