Chaney Instrument 00595XTX2 Wireless Weather Station User Manual
Chaney Instrument Co. Wireless Weather Station Users Manual
Users Manual
The ACURITE® professional wireless weather station comes complete with the following items: 1. Main unit with foot stand for desktop use 2. Wireless Thermo-Hygrometer & mounting bracket 3. Wireless Wind speed sensor & mounting bracket 4. Instruction Manual 5. Quick Start Guide 6. Mounting screws & wall anchors QUICKT STAR TOOLS NEEDED: • Philips type screwdriver: for optional surface mounting of the wireless sensor / brackets. OVERVIEW OF FEATURES WEATHER STATION MAIN UNIT: The main unit measures the indoor environment temperature and humidity and receives weather and time data from the two outdoor wireless sensors. The following sensors send data back to the main unit: 1. Wireless Thermo-Hygrometer/Atomic Clock Sensor 2. Wireless Wind Sensor The wireless weather station receives the wireless sensor data a number of times each minute, updating you with the latest and most accurate weather information on the large, easy-to-read LCD display, using icons and trend indicators. Enjoy using the weather station either on the wall, using the hanging slot by fastening with a nail or provided screw, or on a desktop, using the included snap-on foot stand. The professional wireless weather station is composed of the following features: • Displays the NIST (National Institute of Standards and Technology) WWVB Radio Controlled time and date • Weather data, with programmable alarms for certain weather conditions, and records all minimum and maximum values • Indoor/outdoor temperature in either Fahrenheit or Celsius (user selectable) • Indoor/outdoor relative humidity • Air pressure reading in Hg or hPa • Weather forecast with weather icons and trend indicators • Wind speed and wind direction display with LCD compass • Wind chill temperature display • Heat index temperature display • Dew point temperature display • Time, temperature and storm alarms • Buttons for use: MAX (+), MIN (-), DISPLAY (daily record), CLEAR, SET-UP (on/off/record), ALARM, CHANNEL (off/wave), SNOOZE (alarm off) NIST WWVB RADIO CONTROLLED ATOMIC SIGNAL DESCRIPTION: The National Institute of Standards and Technology government operated WWVB atomic radio signal, located in Fort Collins, Colorado, is the most accurate radio signal, used by television, radio and military for the most split-second time and date information. The time and date display on this weather station is based on the signal provided by the atomic clock in Colorado. WIRELESS THERMO-HYGROMETER ATOMIC CLOCK SENSOR: The thermo-hygrometer atomic clock sensor measures the outdoor temperature and relative humidity. It also includes the radio controlled atomic clock transmitter, which receives data from the atomic clock in Fort Collins, Colorado, and then sends the received data back to the main unit display. The data is sent by a 433MHz radio controlled wireless transmission. Transmission can be received up to 100 feet away in an unobstructed open area. WIRELESS WIND SPEED SENSOR: The wind sensor measures wind speed and wind direction and transmits this information to the main unit display. The data is sent by a 433MHz radio controlled wireless transmission. Transmission can be received up to 100 feet away in an open area. GETTING STARTED MOUNTING AND PLACEMENT CONSIDERATIONS: The wireless transmission distance from the thermo-hygrometer sensor and wind speed sensor to the main unit in open space under ideal conditions is 100ft. Although the signal transmission may travel through solid surfaces or objects, try to place the wireless sensors and main unit in a location with minimal obstructions. The following points should be avoided if possible. • High density of large trees. • High radio frequency areas. • Low-E Glass. • Thick concrete, stone or brick. • The main unit, thermo-hygrometer and wind speed sensors should not be mounted to metal surfaces as this can reduce range of transmission. • Prior to drilling mounting holes or permanently affixing any of the units, please ensure the main unit con receive the signal from the remote sensors in the desired location. • For best reception of the signal from the atomic clock in Fort Collins, Colorado, place the sensor in a location with a direction towards Colorado. • The WWVB signal will be obtained easiest in the nighttime hours when the signal is the strongest. MOUNTING INSTRUCTIONS MAIN UNIT: The included foot mount can be attached to the bottom of the main unit for easy placement on any flat surface. Alternatively, the main unit can be wall mounted in the desired location by using the hang hole on the back of the unit. WIRELESS THERMO-HYGROMEMTER SENSOR: The best place to mount the thermohygrometer sensor is in a location out of direct sunlight and protected by extreme weather conditions, such as under the extension of the home roof, under a covered patio or deck. Mount the bracket that the thermohygrometer sensor will set in at about eye level by using the four included screws. Once the bracket has been properly affixed in the desired location, place the sensor in the bracket holder. The thermo-hygrometer wireless sensor may also be mounted on a pole; which is outlined in the section “OPTIONAL POLE MOUNTING.” Mount With Arrow Pointing Up MOUNTING THE WIRELESS WIND SPEED AND WIND DIRECTION SENSOR: Before permanently mounting the wind speed bracket, make sure that the wind-fan and wind-vane can rotate freely without any disruption. Also note that the wind speed sensor bracket arm must be pointing north. The wind speed sensor should be positioned to allow the wind to flow around the sensor unhindered from all directions for the most accurate and correct readings. OPTIONAL POLE MOUNTING: Both sensors are designed to mount in two ways, either to flat surfaces like wood posts, or to 3/4” schedule 40 PVC pipe (the outside dimension of the pipe actually measures approximately 1, 1/16”). The pipe mounting method is often referred to in these instructions. The ideal mounting scenario would be for the wireless thermo-hygrometer to be mounted on the north side of the building and for the wind sensor to be mounted well away from the building and high in the air. Please test the wireless signal range before permanently mounting. Since PVC pipe is somewhat flexible, if a tall wind sensor mast is being erected, a larger diameter PVC pipe should be used for the base with a reducer fitting placed at the top. Plastic pipes used for mounting are non-conductive and reduce the likelihood of lightening strikes. BATTERIES (not included) NOTE: Do not install batteries in any of the units until you have read through the initial set-up steps in their entirety. BATTERY TYPE: INDOOR UNIT: “AA” (3) alkaline type batteries can be used for the indoor unit. WIRELESS OUTDOOR UNITS: It is recommended that LITHIUM type “AA” batteries be used in any outdoor units when the temperature drops below -4ºF. Alkaline batteries may freeze at very low temperatures and will fail to provide adequate power to the wireless units. MAIN UNIT BATTERY REPLACEMENT: When the low battery indicator icon becomes present, it is recommended that you change the batteries. Replace only with the same or equivalent type of fresh alkaline batteries. BATTERY INSTALLATION: For the first installation, insert the batteries into the two WIRELESS SENSORS FIRST and then into the main unit. Thermo-Hygrometer Sensor: (See illustration next page) Rotate and pull the top casing from the bottom cone by turning the unit upside down and rotating counter-clock wise until casing pulls apart. Insert 2 fresh “AA” batteries (batteries not included). Replace the battery compartment cover and rotate the top back into the bottom piece. Wind Sensor: (See illustration next page) Twist off the top from the bottom and open the battery cover located on the bottom of the sensor. Insert 2 fresh “AA” batteries. (Batteries not included). Replace battery door cover by putting battery cover on half way and then sliding into place. Twist on the top to the bottom piece. Main Unit: Open the battery cover located on the back of the unit and insert 3 fresh “AA” batteries. (Batteries not included). Replace battery door cover. NOTE: When reinstalling the batteries while holding down the “CLEAR” button, all user settings will be cleared and the unit will set back to the factory default settings. If no button is pushed during battery replacement, the last record and user settings will be saved. NOTE: When installing batteries, always install according to the polarity indicated in the battery compartment ( + to + and - to - ). LOW BATTERY INDICATOR: Low Battery Battery O.K. Low battery indicator is displayed on the main unit for the main unit and all wireless sensors. When replacing the batteries, please follow the battery installation procedure as mentioned in this instruction manual. When installing or replacing batteries do not mix battery types or old batteries with new batteries. BATTERY REPLACEMENT: When the low battery indicator icon becomes present, it is recommended that you change the batteries. Replace only with the same or equivalent type of fresh alkaline batteries. This method of battery replacement ensures there will be no loss in MIN/MAX and history data. However, if main unit or sensors have remained without batteries for an extended period of time, the main unit will lose the MIN/MAX and all weather data recordings and will have to be synchronized again. INITIAL SET-UP ACCESSING THE BATTERY COMPARTMENTS Main Unit: Open the battery cover located on the back of the unit. Remove the screw set provided for wall mount use and insert 3 fresh “AA” batteries. (Batteries not included). Replace battery door cover. Top Casing Thermo-Hygrometer Sensor: Rotate and pull the top casing from the bottom cone by turning the unit upside down and rotating counter-clock wise until casing pulls apart. Slide the battery compartment cover (located on the side of the sensor) off. Insert 2 fresh “AA” batteries (batteries not included). Replace the battery compartment cover and rotate the top back into the bottom piece. Battery Door Batteries POWER ON: Once the batteries have been inserted into the wireless sensors, they will automatically begin transmitting data. Thermo-Hygrometer Wind Reception Sensor-reception Optional Rain Gauge Icon Icon Reception Icon Wireless Reception The main unit has wireless signal reception icons in the temperature display area. If there are a low number of “bars” present, you may experience no temperature or wind display ( “--” ) . In either case, you may need to relocate one or both of the units. If most or all 4 of the bars are present, wireless reception is good and no action is required. Bottom Cone no reception great reception OPERATION Wind Sensor: Twist off the top from the bottom and open the battery cover located on the bottom of the sensor. Insert 2 fresh “AA” batteries. (Batteries not included). Replace battery door cover by putting battery cover on half way and then sliding into place. Twist on the top to the bottom piece. NOTE: 1. When installing batteries, always install according to the polarity indicated in the battery compartment. 2. When installing or replacing batteries do not mix battery types or old batteries with new batteries. Top Casing Battery After the main unit and the wireless sensor are both powered on and wirelessly synchronized, no further input is required. The atomic clock will automatically re-synchronize occasionally to ensure the clock is accurate. Battery Door Bottom Casing Battery Atomic Clock Reception Icon B 14 Day Learning Mode This weather station has a patent pending fourteen day learning mode calibration process. During this learning mode the weather station will make altitude calculations that may affect the accuracy of the forecast. Once the 14 day learning mode process is complete, the learning mode icon will disappear and the weather forecast should be ready for superior operation. C Forecast Icon This feature gives you the predicted weather forecast for the next 12 to 24 hours based on an advanced algorithm that includes barometric pressure and temperature. This weather station will provide the most accurate forecast that a single station weather instrument can provide. SIGNAL RECEPTION: OUTDOOR WIRELESS SENSORS: As soon as the main unit is powered up, it will begin to search for the outdoor wireless sensor signals. While in search mode, the bar icons will be animated. During this time, all of the outdoor values will be shown as “---“ until the weather data has been received correctly. To force a signal search, press and hold the “CHANNEL” button for 3 seconds. RADIO CONTROLLED ATOMIC CLOCK: The Radio Controlled Atomic Clock (RCC) signal from Fort Collins, CO is relayed through the wireless thermo-hygrometer sensor. If the RCC signal has successfully been received, “ ” will be displayed. If the RCC signal has not been received, only the icon “ ” will be displayed. The RCC signal is best received at night and may take up to 24 hours to be received initially. REFERENCE GENERAL SET-UP BUTTON OPERATION DESCRIPTIONS: The main unit has 7 buttons for user operation. Some buttons have multiple functions. Please refer to the following for button operation description: The general setting mode allows the user to change several product default settings, which is done by simply accessing one setting after the other by pressing the “SET-UP” button. In normal mode, press and hold the “SET-UP” button for 3 seconds to enter the manual set-up mode. The icon to set will be blinking. If no key is pressed for 30 seconds, the manual set-up mode returns to the normal display mode. The general programming takes the user through the modes listed below. 1. MIN BUTTON: Press the “MIN” button to enter the MIN MODE. The “MIN” icons on the main unit will be displayed, showing minimum temperature, humidity, wind speed and pressure for that day (resets every evening at midnight). Press the “EXIT” button to exit the MIN MODE. The “MIN” icons will disappear. 2. MAX BUTTON: Press the “MAX” button to enter the MAX MODE. The “MAX” icons on the main unit will be displayed, showing maximum temperature, humidity, wind speed and pressure for that day (resets every evening at midnight). Press the “EXIT” button to exit the MAX MODE. The “MAX” icon will disappear. 3. - / + BUTTON: In alarm and set up modes, decreases/ increases time, temp, humidity levels. 4. DISPLAY (DAILY HISTORY) BUTTON: Press the “DISPLAY” button to toggle between the following information in the upper right hand side of the main unit: WIND CHILL, HEAT INDEX, DEW POINT, and RAIN GAUGE (sold separately). 5. DAILY HISTORY(DISPLAY) BUTTON: See pages 11-12 for instructions on viewing daily highs and lows. 6. CLEAR BUTTON: Press the “CLEAR” button to clear any settings currently stored in the main unit. 7. SET-UP (ON/OFF/RECORDS BUTTON): Press and hold for 3 seconds to enter the general set-up mode. 8. ON/OFF (SET-UP): Turns off alarm when beeping; sets alarm when in ALARM mode. 9. RECORDS BUTTON: See page 13 for instructions on viewing long term highs and lows. 1. Manual time setting (hours/minutes), if atomic time is not available. 2. Calendar setting (month/date/year). 3. Time zone setting (P/M/C/E) (Note: zone will be blinking to the right of the WAVE icon). a. P = Pacific Standard Time b. M = Mountain Standard Time c. C = Central Standard Time d. E = Eastern Standard Time 4. Daylight Saving Time setting (ON or OFF) DST ON = Daylight Saving Time enabled. DST OF = Daylight Saving Time disabled. 5. Temperature unit setting (ºC or ºF) 6. Wind speed unit setting (mph/kph/knots) 7. Air pressure unit setting (mbar/hPa/inHg). While in the set-up mode, use “MAX” (+) or “MIN” (-) buttons to adjust the blinking values. Press and hold for rapid scrolling through of the values. Press the “EXIT” button to exit the set-up mode. SELECTABLE DISPLAY MODES: The following information options can be displayed on the main unit above the digital wind direction compass. Press the “DISPLAY” button to toggle between the below weather data information. WIND CHILL: Wind chill is the rapid cooling of the human body caused by air motion. Air motion accelerates the rate of heat transfer from a human body to the surrounding atmosphere, especially when temperatures are low. The wind chill is a calculation of temperature data from the wireless thermo-hygrometer remote sensor and the wind sensor. 10. ALARM BUTTON: Press the “ALARM” button to stop any alarm for one day when the alarm sounds. Press and hold for 3 seconds to enter the alarm set-up mode. See page 11. NOTE: In “SET-UP” and “ALARM” setting mode, pressing either the “MIN” or “MAX” buttons will allow the user to change any values. The user may press and hold the button for rapid scroll through of values. HEAT INDEX: Heat index is the perceived temperature to the human body based on both air temperature and the amount of moisture present in the air. The heat index is a calculation based on the combined temperature and humidity data received from the wireless thermo-hygrometer remote sensor. 11. CHANNEL (EXIT) BUTTON: Press the “CHANNEL” button to view the outdoor temperature and humidity for any additional sensors used. Additional sensors are sold separately. Additional sensors are optional. Press and hold the “CHANNEL” button will force the main unit into signal searching mode. NOTE: Pressing the “EXIT” button will exit all of the MIN/MAX, SET-UP, and ALARM settings while in these modes. DEW POINT: The dew point temperature is the temperature to which the air must be cooled to reach saturation. The dew point is a calculation of temperature and humidity data received from the wireless thermo-hygrometer remote sensor. 12. SNOOZE BAR (TOP OF UNIT): Press the “SNOOZE” bar to enter into the snooze mode for 5 minutes when the time alarm is activated. The ALARM icon will be displayed and blinking. RAIN GAUGE (Sold Separately): When using the ACURITE® on Wireless Rain Gauge models 614/626, displays the rainfall amount from the past 1 hour, 24 hours, 2 days and 19 days, as well as total amount of rainfall recorded by this unit. GENERAL WEATHER STATION FUNCTIONS WEATHER AND TIME ALARMS After the initial and general set-up, the following data will be displayed in different sections on the main unit display. MOON PHASE: The moon phase indicator, found under the date display, shows the current phase of the moon based on the yearly calendar. CALENDAR FUNCTION: The calendar display, found under the time display shows the current month and date with day indicator. FORECAST ICONS: The main unit predicts weather conditions for the next 12 – 24 hours based on the change in temperature and atmospheric pressure. The coverage area is up to 25 miles. Weather forecasts based on atmospheric pressure changes are about 70-75% accurate. As weather conditions cannot be 100% correctly forecasted, we cannot be responsible for any loss caused by an incorrect forecast. More than 20 icons will represent the 24 hr. weather forecast. Some common icons include: SUNNY RAINY / SNOW CLOUDY PARTLY CLOUDY TREND INDICATORS: Trend indicators for outdoor temperature and humidity and wind speed show the trend tendency based on the past and current weather conditions. ALARM SETTING MODE: The alarm setting mode allows the user to change several alarm settings, which is done by accessing one mode after the other, simply by pressing the “ALARM”” button. The individual alarm can be turned on and off by using the “ON/OFF/RECORDS” button. When an alarm goes off, an audible tone will sound for one minute. Press and hold the “ALARM” button for 3 seconds to enter the alarm setting mode. The time display and “AL” for alarm will be blinking. This indicates the user is now in the alarm-setting mode. In alarm setting mode, to activate or deactivate any alarm, press the “ON/OFF ” button. For non-time alarms, the blinking “HH.H” means the high alarm value is to be set. For non-time alarms, the blinking “LL.L” means the low alarm value is to be set. While in the alarm mode, use “MIN” (-) or “MAX” (+) buttons to change any of the values. Press and hold for rapid scroll through of any values. Press the “EXIT” button to exit any of the above alarm modes. Press the “ALARM” button to stop the alarm for one day, or press the “SNOOZE” button to turn the alarm time off for five-minute increments. This weather station also comes equipped with a audible storm alarm. When activated, the storm alarm will sound if there is a sudden or extreme drop in barometric pressure or if there is a constant progressive drop in barometric pressure. NOTE: If no button is pressed for 30 seconds, the alarm setting mode returns to the normal display mode. Pressing the “ALARM” button during the alarm-setting mode scrolls through the following settings: 1. Time alarm setting (hours, minutes) 2. Indoor temperature alarm (high, low) BAROMETRIC BAR GRAPH AND PRESSURE HISTORY: The main unit shows BAROMETRIC pressure in two forms, numerically and as a pressure history graph. The graph indicates the pressure changes (range from +0.24inHg to -0.24inHg/ -8hPa mb to +8 hPa mb) of the current and past 1,2,3,6 and 12 hours. 3. Indoor humidity alarm (high, low) WIND FUNCTIONS: 7. Heat index alarm (high) 5. Outdoor humidity alarm (high, low) 6. Wind chill alarm (low) 8. Dew point alarm (high, low) Digital Compass: The digital compass indicates the direction from which the wind is coming from, marked by the arrow indicator, with 16 possible directions. The wind direction is shown here coming out of the WEST. Wind Speed: The wind speed values are located in the center of the digital compass. The wind speed is transmitted from the wind sensor and is updated approximately every 18 seconds. The wind speed shown here is 4 (mph). 4. Outdoor temperature alarm (high, low, at the current channel) 9. Wind speed alarm 10. Storm alarm MINIMUM & MAXIMUM RECORD MODE The “MIN/MAX” buttons provide the user with information about the minimum and maximum values of today’s weather data. It also acts as an access mode for the daily and long-term records, with the time and date of their recordings. SPEED TO ACCESS THE MIN OR MAX VALUES (TODAY’S HIGH’S AND LOW’S): Press the “MIN” or “MAX” button to display the corresponding highs or lows of the day. Wind Peak: The wind Peak displays the highest recorded wind speed over he past 1 hour. 10 11 (CONTINUED): When pressing the “MIN” or “MAX” button, the unit will show the highest and lowest valves for that day for the following records. Outdoor temperature, outdoor humidity, indoor temperature, indoor humidity, wind speed, wind peak, the selectable display item and barometric pressure. Barometric pressure is displayed in the lower display window. These valves reset at midnight daily. NOTE: To show min/max values for wind chill, heat index, or dew point (the selectable display area), the value of interest must first be displayed by pressing the “DISPLAY” button until the desired value is displayed. DAILY HISTORY: The Daily History is a feature that displays a single value with the date and time of its recording. When the daily history is being displayed, the value, date and time will be blinking. When the unit is in a daily history mode, the unit will display a blinking “dr” next to the time of the recording, indicating Daily History. The main unit automatically stores the last seven days worth of recordings. TO ACCESS THE DAILY HISTORY: While in either the “MIN” or “MAX” mode, press the “DAILY HISTORY” button to show either the “MIN” or “MAX” for any of the values shown in the graph below. Continue to press the “DAILY HISTORY” button to scroll through each of the values shown in the graph below. To review the history of a blinking value, press the “-“ or “+” button to scroll backwards and forwards within the last seven days of recordings. The value, date and time will update to show when the record occurred. NOTE: While reviewing the history for a certain value, pressing the “DAILY HISTORY” button automatically returns the unit to the present-day next value as shown in the graph below. NOTE: Pressing the “exit” button at anytime, returns the unit to normal operating mode. NOTE: Daily records can not be cleared; they automatically adjust on the seven day cycle. Display History Outdoor Temperature Outdoor Humidity Indoor Temperature Indoor Humidity Wind Peak ** Selectable Display Barometric Pressure TO ACCESS THE LONG-TERM RECORDS: While in either the “MIN” or “MAX” mode, press the “RECORDS” button to show the long-term record highs or lows of the weather station. At this point, the unit will display a blinking “Lr” in the second’s window and the unit will show all the record values.These values show the highest or lowest values ever recorded on the weather station. To obtain the historical details for these records, press the “RECORDS” button and the record, along with time and date will be blinking. Press the “RECORDS” button again to scroll through each of the unit’s minimum and maximum record values. CLEARING LONG-TERM RECORDS: To clear long-term records, press either the “MIN” or “MAX” button, then press the “RECORDS” button. At this point, the unit will display a blinking “Lr” in the second’s window and the unit will show all the record values. Press the “CLEAR” button to clear all the minimum or maximum values. All Long-Term records are cleared at once. This feature is most often used at the beginning or end a of a given season. Pressing the “exit” button at anytime, returns the unit to normal operating mode. MAINTENANCE Clean the housing and screen of the base station only with a soft damp cloth. Do not use abrasives or solvents. Do not submerge in water. • Clean the outer housing of the thermo-hygrometer sensor with a soft damp cloth. Do not use abrasives or solvents. Do not take sensor apart. Do not clean funnel of sensor. Do not submerse sensor under running water. • Clean the wind speed and direction sensor only with a soft damp cloth. Do not take sensor apart. Do not use abrasives or solvents. Do not submerge in water. • Should there be damage to any part of main unit and/or sensors, do not attempt to repair, as this will result in loss of any manufacturer guarantee. Please send damaged part(s) to manufacture for repair/replacement. Manufacturer information is located at the end of this user manual. GENERAL CARE OF MAIN UNIT AND WIRELESS SENSORS: • Avoid exposing main unit and wireless sensors to extreme temperatures, keep out of direct sunlight away from water or severe shock. • When the outside temperature falls below -4ºF, the batteries in the wireless sensors may not produce enough current to power the transmitter, if this happens, the main unit will not show an outdoor temperature reading. We recommend the thermohygrometer wireless sensor be brought indoors during prolonged periods of sub-freezing temperatures. RESET On the back of the receiver unit is a small hole labeled “Reset”. Inserting a narrow rod such as a paperclip will reset the unit and restore factory setting. Daily History will be lost but long term records remain in memory. Wind Chill Heat Index Dew Point Rainfall History (If connected with rain gauge) 12 13 “Daily History” 14 15 “Records” REFERENCE: FACTORY DEFAULT SETTINGS MODEL# 00594W 2009 EST Wind Peak 19 Do not return product to retail store. For Technical Assistance and product return information, please contact Customer Care at: 877-221-1252 HOURS: Monday through Friday from 8:00 a.m. to 5:00 pm CST.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2009:10:23 10:50:36+08:00 Modify Date : 2009:10:23 10:54:17+08:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2009:10:23 10:54:17+08:00 Producer : PDF-XChange 3.60.0106 (Windows XP) Format : application/pdf Document ID : uuid:aa3696e0-798e-461f-a799-0d6b14e03008 Instance ID : uuid:f0bf0a38-6724-4417-ab55-ccb1113bf2a8 Page Count : 10EXIF Metadata provided by EXIF.tools