Chung s Electronic 000000-06-007 Wireless Weather Station (433.9MHz Tx) User Manual
Chung's Electronic Co. Ltd. Wireless Weather Station (433.9MHz Tx)
User Manual
MULTI-CHANNEL CABLE FREE REMOTE THERMO-HYGRO SENSOR MODEL: C-8201 USER’S MANUAL INTRODUCTION Thanks for your purchasing of the Remote Sensor. The Remote Sensor is used with the Chung’s 433MHz multi-channel In-Out wireless weather station to monitor the temperature and humidity changes of remote or outdoor sites. Operation is easy and no wire installation is required. MAIN FEATURES 1. LED INDICATOR Flashing when the sensor transmitting a reading. 2.CHANNEL SLIDE SWITCH Designate the channel of the sensor to Channel 1, Channel 2 or Channel 3. 3.RESET BUTTON Reset all settings to default values 4.°C/°F Switches between °C/°F. 5.BATTERY COMPARTMENT Contains 2 AA size batteries. 6.BATTERY DOOR Covers the battery compartment 7.WALL-MOUNT HOLDER Support the sensor on wall 8.FOLDING TABLE STAND For standing the unit on a flat surface TRANSMITTER: 1. Remove the removable stand and screws the back cover off the transmitter. 2. Insert 2 x AA batteries into the battery compartment. Be sure to insert them the right way round (see polarity information +/- in the battery compartment). 3.The receiver can receive humidity and temperature data from up to 3 transmitters. Assign the channel to each transmitter, Channel 1, 2 or 3 respectively by sliding the switch besides the battery compartment. 4. Press the reset key of the transmitter individually by a pin to confirm the channel setting. 5. Select the temperature unit by sliding the °C/°F switch besides the battery compartment. NOTE: 1. Once the channel is assigned to a transmitter, you can only change it by removing the batteries or resetting the unit. 2. Avoid placing the transmitter in direct sunlight, rain or snow. CHANGE CHANNEL Once a channel is assigned to a transmitter, you can change it by removing the batteries and repeating the above procedure, the other way is to select the designated channel and then reset the transmitter. LOW BATTERY WARNING When the low battery indicator displays in the sensor, it will show up in the main unit under the represented channel, replace with 2 new AA batteries at once. OPERATION Once batteries are inserted, the transmitter will start transmitting samplings at 60-64 seconds intervals. The transmitter’s LED are flashing. The temperature unit ℃ / ℉ shows in the receiver is determined by the setting on the receiver. THE RESET BUTTON Refer to the main unit’s manual for further information. This button is used to reset all settings to default values, when changing the channel or malfunctioning. Use a blunt wire to hold down the button to reset it. HOW TO USE THE TABLE STAND OR WALL MOUNTING The transmitter comes with a wall-mount holder and folding stand. Use either to set up the unit. CAUTIONS This unit is engineered to give you years of satisfactory service if you handle it carefully. Follows are a few cautions: 1. Do not immerse the unit in water. 2. Do not leave disabled battery in the watch for a long time and be sure to replace it with new ones. If battery fluid leaks out, it may damage movement components. 3. Avoid rough using or dropping the unit. 4. To clean the unit, use a dry soft cloth or a soft cloth moistened in a solution of water and a mild neutral detergent. Never use solvents (such as benzene, spray cleanser). 5. Always read the user’s manual thoroughly before operating the unit. SPECIFICATIONS Our temperature measuring range: Recommended operating range: Temperature resolution: -20 °C to +60 °C -20 °C to +55°C 0.1 °C / 1°F (above 0 °C) 1 °C / °F (below 0 °C) RF Transmission Frequency: No of remote unit: RF Transmission Range: Temperature sensing cycle: Pressure measuring range: Pressure sampling cycle: Moon phase scanner range: Radio controlled signal: 433MHz up to 3 units Maximum 30 meters around 60 ~ 64 seconds 800mb to 1050mb 15 minutes From 2000 to 2050 Power: DCF77, MCF, WWVB, JJY 3 V, use 2 x AA 1.5V alkaline battery Weight: 53gm Dimension: 40(W) x 131(H) x 23.5(D) mm FCC Remarks: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. MULTI-CHANNEL CABLE FREE REMOTE THERMO-HYGRO SENSOR MODEL: C-8202 USER’S MANUAL INTRODUCTION Thanks for your purchasing of the Remote Sensor. The Remote Sensor is used with the Chung’s 433MHz multi-channel In-Out wireless weather station to monitor the temperature and humidity changes of remote or outdoor sites. Operation is easy and no wire installation is required. MAIN FEATURES 1.LCD Displays the current temperature and humidity monitored by the remote unit alternately. 2.CHANNEL SLIDE SWITCH Designate the channel of the sensor to Channel 1, Channel 2 or Channel 3. 3.RESET BUTTON Reset all settings to default values 4.°C/°F Switches between °C/°F. 5.BATTERY COMPARTMENT Contains 2 AA size batteries. 6.BATTERY DOOR Covers the battery compartment 7.WALL-MOUNT HOLDER Support the sensor on wall 8.FOLDING TABLE STAND For standing the unit on a flat surface TRANSMITTER: 1. Remove the removable stand and screws the back cover off the transmitter. 2. Insert 2 x AA batteries into the battery compartment. Be sure to insert them the right way round (see polarity information +/- in the battery compartment). 3.The receiver can receive humidity and temperature data from up to 3 transmitters. Assign the channel to each transmitter, Channel 1, 2 or 3 respectively by sliding the switch besides the battery compartment. 4. Press the reset key of the transmitter individually by a pin to confirm the channel setting. 5. Select the temperature unit by sliding the °C/°F switch besides the battery compartment. NOTE: 1. Once the channel is assigned to a transmitter, you can only change it by removing the batteries or resetting the unit. 2. Avoid placing the transmitter in direct sunlight, rain or snow. CHANGE CHANNEL Once a channel is assigned to a transmitter, you can change it by removing the batteries and repeating the above procedure, the other way is to select the designated channel and then reset the transmitter. LOW BATTERY WARNING When the low battery indicator displays in the sensor, it will show up in the main unit under the represented channel, replace with 2 new AA batteries at once. OPERATION Once batteries are inserted, the transmitter will start transmitting samplings at 60-64 seconds intervals. The current temperature and humidity will be shown on the transmitter’s LCD. The temperature unit ℃ / ℉ shows in the receiver is determined by the setting on the receiver. THE RESET BUTTON Refer to the main unit’s manual for further information. This button is used to reset all settings to default values, when changing the channel or malfunctioning. Use a blunt wire to hold down the button to reset it. HOW TO USE THE TABLE STAND OR WALL MOUNTING The transmitter comes with a wall-mount holder and folding stand. Use either to set up the unit. CAUTIONS This unit is engineered to give you years of satisfactory service if you handle it carefully. Follows are a few cautions: 1. Do not immerse the unit in water. 2. Do not leave disabled battery in the watch for a long time and be sure to replace it with new ones. If battery fluid leaks out, it may damage movement components. 3. Avoid rough using or dropping the unit. 4. To clean the unit, use a dry soft cloth or a soft cloth moistened in a solution of water and a mild neutral detergent. Never use solvents (such as benzene, spray cleanser). 5. Always read the user’s manual thoroughly before operating the unit. SPECIFICATIONS Our temperature measuring range: Recommended operating range: Temperature resolution: -20 °C to +60 °C -20 °C to +55°C 0.1 °C / 1°F (above 0 °C) 1 °C / °F (below 0 °C) RF Transmission Frequency: No of remote unit: RF Transmission Range: Temperature sensing cycle: Pressure measuring range: Pressure sampling cycle: Moon phase scanner range: Radio controlled signal: 433MHz up to 3 units Maximum 30 meters around 60 ~ 64 seconds 800mb to 1050mb 15 minutes From 2000 to 2050 Power: DCF77, MCF, WWVB, JJY 3 V, use 2 x AA 1.5V alkaline battery Weight: 53gm Dimension: 40(W) x 131(H) x 23.5(D) mm FCC Remarks: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. MULTI-CHANNEL CABLE FREE REMOTE THERMO-HYGRO SENSOR MODEL: C-8203 USER’S MANUAL INTRODUCTION Thanks for your purchasing of the Remote Sensor. The Remote Sensor is used with the Chung’s 433MHz multi-channel In-Out wireless weather station to monitor the temperature and humidity changes of remote or outdoor sites. Operation is easy and no wire installation is required. MAIN FEATURES 1. LED INDICATOR Flashing when the sensor transmitting a reading. 2.outer connect To test the temperature anywhere u need 3.CHANNEL SLIDE SWITCH Designate the channel of the sensor to Channel 1, Channel 2 or Channel 3. 4.RESET BUTTON Reset all settings to default values 5.°C/°F Switches between °C/°F. 6.BATTERY COMPARTMENT Contains 2 AA size batteries. 7.BATTERY DOOR Covers the battery compartment 8.WALL-MOUNT HOLDER Support the sensor on wall 9.FOLDING TABLE STAND For standing the unit on a flat surface TRANSMITTER: 1. Remove the removable stand and screws the back cover off the transmitter. 2. Insert 2 x AA batteries into the battery compartment. Be sure to insert them the right way round (see polarity information +/- in the battery compartment). 3.The receiver can receive humidity and temperature data from up to 3 transmitters. Assign the channel to each transmitter, Channel 1, 2 or 3 respectively by sliding the switch besides the battery compartment. 4. Press the reset key of the transmitter individually by a pin to confirm the channel setting. 5. Select the temperature unit by sliding the °C/°F switch besides the battery compartment. 6. Use the outer connect to test the temperature anywhere u like. NOTE: 1. Once the channel is assigned to a transmitter, you can only change it by removing the batteries or resetting the unit. 2. Avoid placing the transmitter in direct sunlight, rain or snow. CHANGE CHANNEL Once a channel is assigned to a transmitter, you can change it by removing the batteries and repeating the above procedure, the other way is to select the designated channel and then reset the transmitter. LOW BATTERY WARNING When the low battery indicator displays in the sensor, it will show up in the main unit under the represented channel, replace with 2 new AA batteries at once. OPERATION Once batteries are inserted, the transmitter will start transmitting samplings at 60-64 seconds intervals. The transmitter’s LED are flashing. The temperature unit ℃ / ℉ shows in the receiver is determined by the setting on the receiver. THE RESET BUTTON Refer to the main unit’s manual for further information. This button is used to reset all settings to default values, when changing the channel or malfunctioning. Use a blunt wire to hold down the button to reset it. HOW TO USE THE TABLE STAND OR WALL MOUNTING The transmitter comes with a wall-mount holder and folding stand. Use either to set up the unit. CAUTIONS This unit is engineered to give you years of satisfactory service if you handle it carefully. Follows are a few cautions: 1. Do not immerse the unit in water. 2. Do not leave disabled battery in the watch for a long time and be sure to replace it with new ones. If battery fluid leaks out, it may damage movement components. 3. Avoid rough using or dropping the unit. 4. To clean the unit, use a dry soft cloth or a soft cloth moistened in a solution of water and a mild neutral detergent. Never use solvents (such as benzene, spray cleanser). 5. Always read the user’s manual thoroughly before operating the unit. SPECIFICATIONS Our temperature measuring range: Recommended operating range: Temperature resolution: -20 °C to +60 °C -20 °C to +55°C 0.1 °C / 1°F (above 0 °C) 1 °C / °F (below 0 °C) RF Transmission Frequency: No of remote unit: RF Transmission Range: Temperature sensing cycle: Pressure measuring range: Pressure sampling cycle: Moon phase scanner range: Radio controlled signal: 433MHz up to 3 units Maximum 30 meters around 60 ~ 64 seconds 800mb to 1050mb 15 minutes From 2000 to 2050 Power: DCF77, MCF, WWVB, JJY 3 V, use 2 x AA 1.5V alkaline battery Weight: 53gm Dimension: 40(W) x 131(H) x 23.5(D) mm FCC Remarks: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Company : domaincn Source Modified : D:20060712084528 Create Date : 2006:08:14 11:57:57+08:00 Creator Tool : Acrobat PDFMaker 7.0 for Word Modify Date : 2006:08:14 12:03:46+08:00 Metadata Date : 2006:08:14 12:03:46+08:00 Document ID : uuid:d3577abb-fe7e-4bf9-9b16-efe7f39a4ff8 Instance ID : uuid:6b7146ab-0572-4f22-ba57-796d4d8fc76f Version ID : 2 Format : application/pdf Title : MULTI-CHANNEL CABLE FREE REMOTE THERMO-HYGRO SENSOR Creator : r&d Subject : Headline : Page Count : 12 Page Layout : OneColumn Author : r&dEXIF Metadata provided by EXIF.tools