Chung s Electronic CHUNGS-05-001 Wireless Thermo-Hygro Sensor User Manual C 8105 manual

Chung's Electronic Co. Ltd. Wireless Thermo-Hygro Sensor C 8105 manual

User Manual

1 WIRELESS WEATHER STATION C-8105 USER’S INSTRUCTIONS  The multifunctional weather station is equipped with many functions providing thorough weather information to you. The receiver unit has a clear, easy-to-read display that shows weather forecast, indoor temperature, relative humidity, pressure, moon phase, time and date, as well as the temperature and relative humidity measured and transmitted by the sensor. It is able to receive and display readings from up to 3 remote sensors.  The receiver unit retains the minimum and maximum temperatures and relative humidity readings measured at various locations. The 433 MHz technology means no wire installation is required and you can place the sensors anywhere you like.  With radio controlled function, the current time and date are automatically synchronized with the time signal transmitted from Frankfurt (DCF77). The signal can cover a distance of about 1500 km from the Frankfurt transmitter.  MAIN FEATURES:  WEATHTER STATION:                  1. TIME: -  Press it once to view the year. -  Press and hold it for 2 seconds to enter the time setting mode.  2. ALARM: -  Press it to switch to alarm and temperature alarm. -  In alarm mode, press and hold it for 2 seconds to enter the alarm and pre-alarm setting mode.  3. UP:  -  In normal time mode, press it to choose between channel (1), (2) and (3). -  In setting mode, press it to increase the setting value. -  In alarm mode, press it to turn on/off alarm and snooze.  4. DOWN: -  Press and hold it for 3 seconds, release, then press it to change the weather indicator. -  In alarm mode, press it to turn on/off alarm and snooze.
2  5. HISTORY: -  Checking the past 24 hours pressure records.  6. MAX/MIN : -  Press it once to check max./ min. temperature record. -  Press and hold it for 3 seconds to delete the max. and min. record.  7. SNOOZE • LIGHT: -  Press it once, EL backlight keeps on for 5 seconds. -  Press it to stop alarm when it is sounding.  8. Table stand: -  Use to stand on desktop.  9. mb/hPa • inHg: - Switch between mb/hPa or inHg.  10.  °C / °F: - Switch between °C / °F.  11. RESET: -  Press it to set all of the values to factory value. -  In case of mal-function, the unit may be required to reset.  12. WEATHER FORECAST WINDOW: -  Displays the weather forecast indicator.  13.  OUTDOOR TEMPERATURE AND HUMIDITY WINDOW: -  Shows the outdoor temperature-trend, humidity-trend, current temperature, current humidity or the maximum or minimum recorded temperature and humidity.  14. INDOOR TEMPERATURE AND HUMIDITY WINDOW:  -  Shows the indoor temperature-trend, humidity-trend, current temperature, current humidity or the maximum or minimum recorded temperature and humidity.  15. ATMOSPHERIC PRESSURE CHART:  -  Shows the atmosphere pressure trend of the last 24 hours.  16. ATMOSPHERE PRESSURE WINDOW:  -  Displays the current atmospheric pressure data and indicates the last 24 hours pressure history.  17. CALENDAR WINDOW:  -  Displays the date, year, day of the week and moon phase.  18. CLOCK WINDOW:  -  Displays the time and radio controlled signal.
3  TRANSMITTER:             1. LED indicator:  -  Flashes when the remote unit transmits a reading.  2. Two-line LCD: -  Displays the current temperature and humidity monitored by the remote unit.  3.  Channel slide switch: -  Assign the transmitter Channel 1, Channel 2 or Channel 3.  4.  °C / °F: - Switches between °C / °F.  5. RESET: -  Return all values to default value.  6. Battery compartment: -  Accommodates 2 AAA size batteries. -  7. Battery door:  8.  Wall mount holder: -  Supports the transmitter in wall mounting.  9.  Folding table stand  BEFORE YOU BEGIN  TRANSMITTER: 1.  Remove the removable stand, unscrew the screws of the back cover and lift the cover off. 2.  Insert 2 x AAA batteries into the battery compartment. Be sure to insert them the right way round (see polarity information +/- in the battery compartment). 3.  The receiver can receive humidity and temperature data from up to 3 transmitters. Assign the channel to each transmitter, Channel 1, 2 or 3 respectively by sliding the switch besides the battery compartment. 4.  Press the reset key of the transmitter individually by a pin to confirm the channel setting. 5.  Select the temperature unit by sliding the °C / °F switch besides the battery compartment.
4 6.  Re-fix the battery compartment door, and secure its screws in evenly and diagonally. NOTE: 1. Once the channel is assigned to a transmitter, you can only change it by removing the batteries or resetting the unit. 2. Avoid placing the transmitter in direct sunlight, rain or snow.  WEATHER STATION: 1.  Remove the battery door and insert 3 x AA batteries into the battery compartment. Make sure you insert the batteries the right way round (see polarity information +/- in the battery compartment). 2.  Close the battery compartment. 3.  Press reset button to re-start the clock and it will synchroise the channels of the transmitter automatically.  NOTE: 1.  If extra transmitter is added in the future, press reset button to re-start the clock and synchronise the channel once again. 2.  The building material and the position of the receiver and transmitter affect the effective range. So try various set-ups will help to obtain the best result. 3.  Place the units away from metal objects and electrical appliances to minimize the interference. Position the receiver and the transmitter within effective transmission range: 30 meters in usual circumstances.  SETTING WEATHER INDICATOR  Important: To get a better result of weather forecast indicator, please set the weather forecast icon according to the current weather condition. 1.  In normal time mode, press and hold DOWN key for 3 seconds, weather indicator flashing. 2.  Press DOWN key to change the weather indicator in this order: Slightly cloudy – Cloudy – Rainy – Storm – Sunny 3.  Choose the suitable indicator according to the current weather. 4.  Press TIME key to return to the normal mode or let it automatically return to normal mode after 30 seconds without pressing any keys. Slightly cloudy           Cloudy       Rainy      Storm     Sunny
5  NOTE: 1. Do not set the weather indicator when it is raining. Raining will give unstable data. 2. Do not set the weather indicator in nighttime.  RECEPTION OF RADIO CONTROLLED TIME SIGNAL The time and date are radio-controlled. The current time and date are automatically synchronized with the time signal transmitted from Frankfurt, Germany (DCF77), provided the device is within about of 1500 km range of the transmitter.  When used for the first time (after inserting the batteries or pressing RESET), the clock starts receiving time signals and the reception display flashes.  SIGNAL STRENGTH INDICATOR The signal indicator displays signal strength in 3 levels. Wave segment flashing means time signals are being received. The signal quality could be classified into three types:      NOTE: 1.  It is strongly recommended to start this clock at nighttime and let the clock receive signal automatically during midnight. Everyday the unit will automatically search for the time signal at 2:00, 8:00, 14:00 and 20:00. 2.  Always place the unit away from interfering sources such as TV set, computer, etc. 3.  Avoid placing the unit on or next to metal plate. 4.  Closed area such as airport, basement, tower block or factory is not recommended. 5.  Do not start reception on a moving article such as vehicle or train.
6  English German French Spanish  Italian SUN SON DIM DOM DOM MON MON  LUN  LUN  LUN TUE DIE MAR MAR MAR WED MIT MER MIE  MER THU DON  JEU  JUE  GIO FRI FRE VEN VIE  VEN SAT SAM SAM SAB  SAB  MANUAL TIME SETTING If you are out of the reach of the Radio Controlled Tranmsitter or if the reception is not reachable, the time can be set manually. As soon as the transmitter is received again, the clock will automatically synchronise with the received time.  1.  In normal time mode, press and hold TIME key for 2 seconds, hour flashing, press UP or DOWN key to change its value. 2.  Press TIME key again, minute flashing, press press UP or DOWN key to change its value. 3.  Repeat the above operation to set the time in this order: Hour – Minute – Second – 12/24 hour – Year – Month – Date – Day language. 4.  5 languages weekday setting sequence is : English-GB / French-FR / German-DE / Spanish-ES / Italian-IT. 5.  After setting completed, press TIME key to exit setting mode, or let it exit automatically in 30 seconds without pressing any key.              ALARM AND SNOOZE SETTING 1.  In normal time mode, press ALARM key once to enter the alarm mode. Press UP or DOWN key once, alarm is on with the bell indicator displayed. Press UP or DOWN key again to turn on SNOOZE with Zz displayed. Press UP or DOWN key to turn off ALARM and SNOOZE. 2.  In normal mode or alarm mode, press and hold ALARM key for 2 seconds, hour flashing. Press UP or DOWN key to set the value. Repeat the same operation to set the alarm minute. 3.  After setting completed, press ALARM key to return to normal mode, or let it exit automatically 30 seconds later without pressing any key.  NOTE: 1.  The alarm will automatically turn on when setting the alarm time. 2.  The EL backlight will keep on for 5 seconds when the alarm is sounding. 3.  Once the snooze is turn on, the 4-step crescendo alarm will sound 4 times in 5-minute interval. The alarm duration is 120 seconds.          Alarm OFF            Alarm ON       Alarm and Snooze ON
7      SETTING THE TEMPERATURE ALARM Use this function to be woken up at a determined period of time earlier (1-30 minutes), if one of the transmitter‘s temperatures is below -1 °C. 1.  In normal time mode, press ALARM key twice to enter pre-alarm mode, press UP or DOWN key to turn pre-alarm on. 2.  Press and hold the ALARM key for 2 seconds, pre-alarm time flashing, press UP or DOWN key to change its value.  NOTE: 1.  To activate pre-alarm function, ALARM must be on.  Temperature alarm ON      Pre-alarm 15 minutes        Pre-alarm mode        VIEWING THE CHANNEL The default channel is channel 1. In normal time mode, press UP key to view the channel from 1 to 3.  HOW TO READ INDOOR AND OUTDOOR TEMPERATURE & HUMIDITY RECORDS Change the temperature unit by sliding °C / °F slide switch to °C for Centigrade or °F for Fahrenheit. If the readings go above or below the specified range, the receiver and transmitter will keep show the last record within the operation range.  NOTE: 1.  If no signals are received or the transmission is interfered with, “---“ appears in the display. 2.  Locate the clock in other position and make sure the transmission is within the effective range of 30 meters approx.   3.  After several trials but in vain, please reset the clock thoroughly. Try out where your multifunctional alarm clock receives the signals best.  CHECKING AND DELETING MAX./MIN/ TEMPERATURE & HUMIDITY REOCRDS
8 1.  Press MAX/MIN key to check Maximum temperature and humidity records. Press it twice to check the Minimum records. Press it thrice to exit. 2.  Press and hold MAX/MIN key for 3 seconds to delete the records.   MAX. Temperature / humidity record        MIN. Temperature / humidity record        WEATHER TREND The temperature-trend, humidity-trend and pressure-trend indicators show the trends of changes for the last few minutes. Arrows indicate a rising, steady or falling trend.  Arrow indicator      Temperature trend  Rising Steady Falling Arrow indicator        Humidity trend  Rising  Steady  Falling Arrow indicator      Pressure trend  Rising  Steady  Falling   WEATHER FORECAST The built-in barometer can notice atmospheric pressure changes. Based on the data collected, it can predict the weather condition in the forthcoming 6-12 hours. The effective range covers area of about 30 to 50 km  NOTE: 1.  The accuracy of a general pressure-based weather forecast is about 70 to 75% , and therefore, cannot be held responsible for any inconveniences caused by an inaccurate data. 2.  The weather forecast is meant for next 6 to 12 hours. It may not necessarily reflect the current situation.
9 3.  The “Sunny” icon, when applies to nighttime, implies clear weather.     Slightly cloudy       Cloudy        Rainy      Storm     Sunny     NOTE:THE COMFORT-LEVEL ICONS The comfort level icons COMFORT, DRY and WET will tell you what the current environment is.  Comfort level  Icon displayed  Temperature Range  Humidity Range  Current Environment COMFORT    20 °C to 25 °C (68 °F to 77°F) 40% RH ~ 70% RH  Ideal range for both temperature and relative humidity   WET   -5 °C to 50 °C (23 °F to 122°F) Over 70% RH Excess moisture DRY   -5 °C to 50 °C (23 °F to 122°F) Below 70% RH Insufficient moisture  No Indicator Less than 20 °C (68 °F ) or more than 25 °C ( 77°F)40% RH to 70% RH  No comment  PAST 24 HOURS PRESSURE RECORDS The current and historical barometric pressure is shown on the atmospheric pressure window. The atmospheric pressure can be displayed in mb/hPa or inHg by selecting the atmospheric pressure slide switch at the case back.  Checking the pressure history for a particular hour during the past 24 hour’s pressure, press the HISTORY button. Each press on the button will go back by an hour. The recorded atmospheric changes for the past 24 hours are displayed in a bar chart above the atmospheric pressure window.
10       ABOUT THE MOON PHASE: The unit has 8 different moon phases. It will change according to the lunar calendar. 1. New moon 2. Waxing crescent 3. First quarter 4. Waxing Gibbous 5. Full moon 6. Waning Gibbous 7. Last quarter 8. Waning crescent  LOW BATTERY INDICATOR When the battery does not have enough power to operate the unit, the low battery indicator will appear to remind you to replace with new batteries. Transmitter low battery indicates    Transmitter low battery indicator    Receiver low battery indicator         ( shows in the main unit)    NOTE Attention should be drawn to the environmental aspects of battery disposal.    USINGTHE TABLE STAND OR WALL MOUTING The receiver has both desk-top and wall-mounting structure. Fix the separate wall-mounting stand on the wall by screws. Push the stand of the clock upward, hang it on the wall-mounting stand by its recessed holes.  For the transmitter, fix the wall-mount holder on the wall or simply place it on the table.
11        NOTE  Under the environment with radio frequency interference, the sample could not maintain communication link and resume to normal when interference stops.  FCC Remarks:  This device complies with Part 15 of the FCC Rules.    Operation is subject to the following two conditions:   (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.    Warning:    Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.    NOTE:    This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.    These limits are designed to provide reasonable protection against harmful interference in a residential installation.    This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.   However, there is no guarantee that interference will not occur in a particular installation.    If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.  SPECIFICATIONS  MAIN UNIT Indoor temperature measurement range:    -5 °C to +50 °C
12 Recommended operating range:        0 °C to +45 °C Temperature resolution:      0.1 °C / 1°F (above 0 °C)           1 °C / °F (below 0 °C)  Indoor relative humidity measurement range:    20% RH to 90% RH Recommended operating range:       20% RH to 90% RH  Resolution:        1% RH  REMOTE SENSOR Our temperature measuring range:        -20 °C to +60 °C Recommended operating range:        -20 °C to +50 °C Temperature resolution:     0.1 °C / 1°F (above 0 °C)           1 °C / °F (below 0 °C)  Remote relative humidity measuring range:   20% RH to 90% RH Recommended operating range:       20% RH to 90% RH Resolution:        1%RH   RF Transmission Frequency:    433MHz No of remote unit:      up to 3 units RF Transmission Range:     Maximum 30 meters Temperature sensing cycle:        around 60 ~ 64 seconds   Pressure measuring range:     800mb to 1050mb Pressure sampling cycle:      15 minutes  Moon Phase Scanner Range:     From 2000 to 2050  Radio Controlled Signal:      DCF77  Power:  Main unit:        4.5 V, use 3 x AA 1.5V alkaline battery Remote sensor:       3 V, use 2 x AAA 1.5V alkaline battery  Weight Main unit:        298gm Remote sensor:       53gm  Dimension Main unit:        115 (W) x 220 (H) x 90(D) mm Remote sensor:             65 (W) x 93 (H) x 27 (D) m