CipherLab 1560 BT Barcode scanner User Manual 1560 Series Barcode Scanner

CipherLab Co., Ltd. BT Barcode scanner 1560 Series Barcode Scanner

Manual

     1560/1562 BT Barcode Scanner  Setup labels included.      Version 1.01
 Copyright © 2009 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided under a license agreement containing restrictions on use and disclosure and is also protected by copyright law.    Reverse engineering of the software is prohibited. Due to continued product development this information may change without notice.  The information and intellectual property contained herein is confidential between CIPHERLAB and the client and remains the exclusive property of CIPHERLAB CO., LTD.  If you find any problems in the documentation, please report them to us in writing.  CIPHERLAB does not warrant that this document is error-free. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written permission of CIPHERLAB CO., LTD. For product consultancy and technical support, please contact your local sales representative. Also, you may visit our web site for more information. The CipherLab logo is a registered trademark of CIPHERLAB CO., LTD.   All brand, product and service, and trademark names are the property of their registered owners. The editorial use of these names is for identification as well as to the benefit of the owners, with no intention of infringement.   CIPHERLAB CO., LTD.  Website: http://www.cipherlab.com
 FOR USA This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FOR CANADA This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled "Digital Apparatus," ICES-003 of Industry Canada. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de Classe B prescrites dans la norme sur le material brouilleur: "Appareils Numeriques," NMB-003 edictee par l'Industrie.  FOR HAND-HELD PRODUCT WITH RF FUNCTIONS The 1560/1562 unit (FCC ID: Q3N-1560) complies with FCC radiation exposure limits set forth for uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C to OET65. The 1560 unit has very low level of RF energy that it is deemed to comply without testing of specific absorption ratio (SAR).   IMPORTANT NOTICES
 The 3656 unit (FCC ID: Q3N-3656) complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. It only operated in hand-held used. If you only transfer data to Host wirelessly, please keep the minimum distance 20 cm between machine & your body. FOR PRODUCT WITH LASER Per FDA and IEC standards, the scan engines described in this manual are not given a laser classification. However, the following precautions should be observed: CAUTION This laser component emits FDA / IEC Class 2 laser light at the exit port. Do not stare into beam. SAFETY PRECAUTIONS RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.  The use of any batteries or charging devices, which are not originally sold or manufactured by CipherLab, will void your warranty and may cause damage to human body or the product itself.  DO NOT disassemble, incinerate or short circuit the battery.  DO NOT expose the scanner or the battery to any flammable sources.  For green-environment issue, it's important that batteries should be recycled in a proper way.    Under no circumstances, internal components are self-serviceable.  The charging and communication cradle uses an AC power adaptor. A socket outlet shall be installed near the equipment and shall be easily accessible. Make sure there is stable power supply for the mobile computer or its peripherals to operate properly. CARE & MAINTENANCE  Use a clean cloth to wipe dust off the scanning window and the body of the scanner as well as the cradle. DO NOT use/mix any bleach or cleaner.  If you want to put away the scanner for a period of time, download the collected data to a host computer when in the memory mode, and then take out the battery. Store the scanner and battery separately.    When the scanner resumes its work, make sure the battery is fully charged before use.  If you shall find the scanner malfunctioning, write down the specific scenario and consult your local sales representative.
 Version  Date  Notes 1.01  June 3, 2009   Modified: 1.10 Auto-Sense Mode — Power supply cord is required.  Modified: Appendix II Host Serial Commands 1.00  Apr. 29, 2009  Initial release  RELEASE NOTES
  CONTENTS IMPORTANT NOTICES ...................................................................................................................... - 3 - For USA .......................................................................................................................................... - 3 - For Canada .................................................................................................................................... - 3 - For Hand-held Product with RF Functions ................................................................................... - 3 - For Product with Laser .................................................................................................................. - 4 - Safety Precautions ........................................................................................................................ - 4 - Care & Maintenance ..................................................................................................................... - 4 - RELEASE NOTES.............................................................................................................................. - 5 - INTRODUCTION.................................................................................................................................... 1 Getting Familiarized with 1560/1562 and 3656 ........................................................................... 2 Installing the Battery to 1560/1562 .......................................................................................... 2 Setting up 3656 ........................................................................................................................... 3 Charging the Battery via 3656 .................................................................................................... 5 Inside the Package............................................................................................................................ 6 Product Highlights ............................................................................................................................. 6 QUICK START ....................................................................................................................................... 7 Enter Configuration Mode................................................................................................................. 9 Exit Configuration Mode.................................................................................................................... 9 Default Settings...............................................................................................................................10 Save User Settings as Defaults.................................................................................................10 Restore User Defaults................................................................................................................10 Restore System Defaults ........................................................................................................... 10 Read a Setup Label.........................................................................................................................11 Configure Parameters................................................................................................................ 11 List the Current Settings............................................................................................................15 UNDERSTANDING THE BARCODE SCANNER .................................................................................... 17 1.1 Battery .......................................................................................................................................17 1.1.1 How to Operate the Scanner ...........................................................................................17 1.1.2 Auto Power Off..................................................................................................................18 1.2 Memory ..................................................................................................................................... 19 1.2.1 Transmit Buffer ................................................................................................................19 1.2.2 Memory Mode ..................................................................................................................20 1.3 LED Indicator ............................................................................................................................22 1.3.1 Good Read LED ................................................................................................................23 1.3.2 Good Read LED Duration.................................................................................................23 1.4 Beeper.......................................................................................................................................24 1.4.1 Beeper Volume.................................................................................................................25 1.4.2 Good Read Beep ..............................................................................................................26 1.4.3 Low Battery Alarm ............................................................................................................27 1.5 Send “NR” to Host ....................................................................................................................28
 1560 Series Barcode Scanner User Guide  1.6 Scan Modes ..............................................................................................................................29 1.6.1 Continuous Mode.............................................................................................................30 1.6.2 Test Mode.........................................................................................................................31 1.6.3 Laser Mode.......................................................................................................................31 1.6.4 Auto Off Mode...................................................................................................................31 1.6.5 Auto Power Off Mode .......................................................................................................32 1.6.6 Aiming Mode..................................................................................................................... 32 1.6.7 Multi-Barcode Mode.........................................................................................................33 1.6.8 Alternate Mode.................................................................................................................33 1.7 Scanning Timeout.....................................................................................................................34 1.8 Delay between Re-read ............................................................................................................35 1.9 Effective Decoding Area ...........................................................................................................36 1.9.1 Positioning Window.......................................................................................................... 36 1.9.2 Adjusting Window.............................................................................................................36 1.10 Auto-Sense Mode (1560 Only) ..............................................................................................38 1.11 CCD Sensor Always Active (1560 Only).................................................................................39 1.12 Negative Barcodes .................................................................................................................39 1.13 Symbologies Supported .........................................................................................................40 1.13.1 Read Redundancy for All Symblogies ...........................................................................41 1.13.2 Addon Security for UPC/EAN Barcodes ........................................................................ 42 SELECTING OUTPUT INTERFACE .......................................................................................................43 2.1 BT HID........................................................................................................................................44 2.1.1 Activate BT HID & Select Keyboard Type........................................................................44 2.1.2 Reset Connection.............................................................................................................45 2.1.3 Keyboard Settings............................................................................................................ 46 2.1.4 Inter-Function Delay.........................................................................................................50 2.2 BT SPP.......................................................................................................................................51 2.2.1 Activate BT SPP ................................................................................................................51 2.2.2 Inter-Function Delay.........................................................................................................51 2.2.3 ACK/NAK Timeout............................................................................................................52 2.3 Keyboard Wedge via 3656 ......................................................................................................53 2.3.1 Activate Keyboard Wedge & Select Keyboard Type.......................................................53 2.3.2 Keyboard Settings............................................................................................................ 54 2.3.3 Inter-Character Delay .......................................................................................................60 2.3.4 Inter-Function Delay.........................................................................................................60 2.4 RS-232 via 3656 ......................................................................................................................61 2.4.1 Activate RS-232 Interface ...............................................................................................61 2.4.2 Baud Rate.........................................................................................................................61 2.4.3 Data Bits ...........................................................................................................................62 2.4.4 Parity .................................................................................................................................62 2.4.5 Stop Bit .............................................................................................................................63 2.4.6 Flow Control......................................................................................................................63 2.4.7 Inter-Character Delay .......................................................................................................64 2.4.8 Inter-Function Delay.........................................................................................................64 2.4.9 ACK/NAK Timeout............................................................................................................65 2.5 USB HID via 3656.....................................................................................................................66 2.5.1 Activate USB HID & Select Keyboard Type .....................................................................66 2.5.2 Keyboard Settings............................................................................................................ 68 2.5.3 Inter-Function Delay.........................................................................................................72
 1560 Series Barcode Scanner User Guide 2.6 USB Virtual COM via 3656.......................................................................................................73 2.6.1 Activate USB Virtual COM ................................................................................................73 2.6.2 Inter-Function Delay.........................................................................................................73 2.6.3 ACK/NAK Timeout............................................................................................................74 SETTING UP A WPAN CONNECTION ..................................................................................................75 3.1 Connecting via 3656 ................................................................................................................ 76 3.1.1 Connect to 3656 .............................................................................................................. 76 3.1.2 Change Interface..............................................................................................................77 3.2 Connecting via Bluetooth® Dongle ..........................................................................................78 3.2.1 Change Interface..............................................................................................................78 3.2.2 Configure Related Settings..............................................................................................79 3.2.3 Connect to Dongle............................................................................................................82 CHANGING SYMBOLOGY SETTINGS.................................................................................................. 89 4.1 Codabar.....................................................................................................................................90 4.1.1 Start/Stop Characters Selection .....................................................................................90 4.1.2 Start/Stop Transmission..................................................................................................91 4.1.3 CLSI Conversion ...............................................................................................................91 4.2 Code 25 – Industrial 25........................................................................................................... 92 4.2.1 Start/Stop Pattern Selection ...........................................................................................92 4.2.2 Checksum Verification .....................................................................................................93 4.2.3 Checksum Transmission..................................................................................................93 4.2.4 Code Length Qualification ...............................................................................................94 4.3 Code 25 – Interleaved 25........................................................................................................95 4.3.1 Start/Stop Pattern Selection ...........................................................................................95 4.3.2 Checksum Verification .....................................................................................................96 4.3.3 Checksum Transmission..................................................................................................96 4.3.4 Code Length Qualification ...............................................................................................97 4.4 Code 25 – Matrix 25 ................................................................................................................98 4.4.1 Start/Stop Pattern Selection ...........................................................................................98 4.4.2 Checksum Verification .....................................................................................................99 4.4.3 Checksum Transmission..................................................................................................99 4.4.4 Code Length Qualification .............................................................................................100 4.5 Code 39...................................................................................................................................101 4.5.1 Start/Stop Transmission................................................................................................101 4.5.2 Checksum Verification ...................................................................................................101 4.5.3 Checksum Transmission................................................................................................102 4.5.4 Standard/Full ASCII Code 39 ........................................................................................102 4.6 Code 93...................................................................................................................................103 4.7 Code 128 ................................................................................................................................103 4.8 EAN-8.......................................................................................................................................104 4.8.1 Convert to EAN-13..........................................................................................................105 4.8.2 Checksum Transmission................................................................................................105 4.9 EAN-13 ....................................................................................................................................106 4.9.1 ISBN Conversion.............................................................................................................107 4.9.2 ISSN Conversion.............................................................................................................107 4.9.3 Checksum Transmission................................................................................................107 4.10 GS1-128 (EAN-128) .............................................................................................................108 4.10.1 Code ID Transmission..................................................................................................108
 1560 Series Barcode Scanner User Guide  4.10.2 Field Separator (GS Character)...................................................................................108 4.11 ISBT 128 ...............................................................................................................................109 4.12 MSI ........................................................................................................................................110 4.12.1 Checksum Verification.................................................................................................110 4.12.2 Checksum Transmission .............................................................................................111 4.12.3 Code Length Qualification ...........................................................................................112 4.13 French Pharmacode.............................................................................................................113 4.13.1 Checksum Transmission .............................................................................................113 4.14 Italian Pharmacode ..............................................................................................................114 4.14.1 Checksum Transmission .............................................................................................114 4.15 Plessey ..................................................................................................................................115 4.15.1 Convert to UK Plessey .................................................................................................115 4.15.2 Checksum Transmission .............................................................................................115 4.16 GS1 DataBar (RSS Family) ..................................................................................................116 4.16.1 Code ID Selection ........................................................................................................116 4.16.2 GS1 DataBar Omnidirectional (RSS-14).....................................................................116 4.16.3 GS1 DataBar Expanded (RSS Expanded)...................................................................117 4.16.4 GS1 DataBar Limited (RSS Limited) ...........................................................................118 4.17 Telepen .................................................................................................................................120 4.17.1 Telepen Output – Full ASCII/Numeric ........................................................................120 4.18 UPC-A.....................................................................................................................................121 4.18.1 Convert to EAN-13 .......................................................................................................122 4.18.2 System Number Transmission....................................................................................122 4.18.3 Checksum Transmission .............................................................................................122 4.19 UPC-E.....................................................................................................................................123 4.19.1 System Number Selection...........................................................................................124 4.19.2 Convert to UPC-A..........................................................................................................124 4.19.3 System Number Transmission....................................................................................125 4.19.4 Checksum Transmission .............................................................................................125 DEFINING OUTPUT FORMAT............................................................................................................127 5.1 Letter Case..............................................................................................................................127 5.2 Character Substitution ...........................................................................................................128 5.2.1 Select a Set for Character Substituion .........................................................................128 5.2.2 Symbologies for Character Substitution (All 3 Sets) ....................................................129 5.3 Prefix/Suffix Code...................................................................................................................134 5.4 Code ID....................................................................................................................................135 5.4.1 Select Pre-defined Code ID............................................................................................135 5.4.2 Change Code ID..............................................................................................................136 5.4.3 Clear Code ID Settings...................................................................................................138 5.5 Length Code............................................................................................................................139 5.6 Multi-Barcode Editor...............................................................................................................142 5.6.1 Edit a Concatenation of Barcodes ................................................................................143 5.6.2 Activate the Concatenation of Barcodes ......................................................................144 5.7 Removal of Special Character ...............................................................................................145 APPLYING FORMATS FOR DATA EDITING........................................................................................147 6.1 Format Selection ....................................................................................................................148
 1560 Series Barcode Scanner User Guide 6.1.1 Activate Editing Formats................................................................................................148 6.1.2 Exclusive Data Editing....................................................................................................149 6.2 Editing Format.........................................................................................................................150 6.2.1 Select Format to Configure............................................................................................151 6.2.2 Restore Default Format .................................................................................................152 6.2.3 Define Data Criteria .......................................................................................................153 6.2.4 Divide Data into Fields...................................................................................................156 6.2.5 Field Settings..................................................................................................................158 6.2.6 Field Transmission Sequence .......................................................................................164 6.3 Programming Examples .........................................................................................................166 6.3.1 Example I ........................................................................................................................166 6.3.2 Example II .......................................................................................................................167 SPECIFICATIONS ..............................................................................................................................169 FIRMWARE UPGRADE......................................................................................................................171 How to Upgrade 1560/1562 Firmware.......................................................................................171 Using 3656...............................................................................................................................171 Using a Generic Dongle ...........................................................................................................173 How to Upgrade 3656 Firmware ..................................................................................................175 Upgrading 3656 CPU Firmware...............................................................................................175 Upgrading 3656 USB Bridge Firmware...................................................................................177 HOST SERIAL COMMANDS ..............................................................................................................179 1560/1562 Serial Commands ....................................................................................................179 Example ....................................................................................................................................180 3656 Serial Commands................................................................................................................181 Example ....................................................................................................................................184 KEYBOARD WEDGE TABLE ..............................................................................................................185 Key Type.........................................................................................................................................185 Key Status......................................................................................................................................186 User-defined Scan Code ...............................................................................................................186 NUMERAL SYSTEMS........................................................................................................................187 Decimal System.............................................................................................................................187 Hexadecimal System.....................................................................................................................188 ASCII Table.....................................................................................................................................189 Entering PIN Code for Authentication ..........................................................................................190 Use Preset PIN..........................................................................................................................190 Disable Authentication or Use Random PIN...........................................................................191
    1 Update  CipherLab’s 1560 Series Barcode Scanners are specifically designed to answer your mobile demands. The versatile scanners are designed to help accelerate productivity while lowering the total cost of ownership. Intensive data collection jobs are made easier with fast, accurate barcode scanning in various working environments, especially in small businesses. Integrating short-distance wireless technology to small-form-factor scanners, the 1560/1562 scanners are ideal for carrying around, and thus give workers tether-free mobility anytime anywhere and get job done more efficiently. This line of scanners deliver data over a wireless personal network at a range of up to 90 meters and a prolonged battery life to keep business running. Owing to the slim, ergonomic design, extremely low power consumption, and powerful decoding capability, the 1560 Series Barcode Scanners are the best choice for the following applications –    Receiving in Retail  Product labeling & Tracking  Shelf Product Replenishment  Mobile Point of Sale (POS)    Mobile Inventory Management  Order Picking & Staging  Work-In-Process Tracking  Material Flow Control  Transportation & Distribution  Warehousing  Asset Management  This manual contains information on operating the scanner and using its features. We recommend you to keep one copy of the manual at hand for quick reference or maintenance purposes. To avoid any improper disposal or operation, please read the manual thoroughly before use.   Thank you for choosing CipherLab products!     INTRODUCTION
2 Enter Setup 1560 Series Barcode Scanner User Guide  GETTING FAMILIARIZED WITH 1560/1562 AND 3656 INSTALLING THE BATTERY TO 1560/1562 When you first receive the package, the rechargeable battery is stored separately from the scanner. Insert the battery into the scanner first so that it can be charged when sitting in the Auto-Sense stand.   Note:  Any improper handling may reduce the battery life. 1) Hold the scanner still and insert the battery into the battery compartment at the bottom of the scanner. 2) Slide the battery latch to lock the battery in the compartment. 3) Hold down the trigger about 2 seconds to turn on the scanner. The scanner will respond with a long beep and its LED will come on and off shortly.               Note:  (1) To turn off the scanner, remove the battery. Refer to settings of “Auto Power Off”.             (2) For shipping and storage purposes, save the scanner and the battery separately. This will keep the battery in good condition for future use.     (3) When the battery charge becomes low, you will find the scanner cannot emit scan beam and its power-on beep sounds differently.
    3 Update  Introduction  SETTING UP 3656 Capable of charging 1560/1562, the 3656 stand is specifically designed for the scanner to communicate with a host computer wirelessly. The connection between the scanners and 3656 is made easy and reliable. Refer to 3.1.1 Connect to 3656. The 3656 stand is also an Auto-Sense stand when used with the scanner set to Auto-Sense mode.    Two LED indicators are provided for communications status and battery charging status. Power LED  Meaning Red, solid  Power ON ---   Power OFF Communication LED  Meaning ---  Blue, solid Initialize Red, solid ---  Failed to establish a USB connection Red, solid Blue, flashing Serial command mode with USB Virtual COM or RS-232: wait 3 seconds for starting a serial command Red, flashing Blue, flashing Serial command mode with USB HID: wait 3 seconds for pressing [NumLock] or [CapsLock] 5 times via keyboard ---  Blue, flashing Wait for connection request from the scanner (Slow flash at 0.5 Hz)
4 Enter Setup 1560 Series Barcode Scanner User Guide  ---  Blue, flashing Connected with the scanner (Fast flash at 1 Hz) Red, solid Blue, flashing Failed to send data to host via USB Virtual COM (Fast flash at 1 Hz) Red, flashing ---  Enter Download Mode
    5 Update  Introduction  CHARGING THE BATTERY VIA 3656 The battery may not be charged to full for shipment. When you first receive the package, you will need to charge the battery to full before using the scanner.   Note: It takes approximately 3 hours to charge the battery to full (from the power adaptor). If the two pivot bolts are not tightened properly, charging error may occur. 1) Install the battery to the scanner. 2) Seat the scanner in the 3656 stand. 3) Connect the 3656 stand to your computer or notebook via the USB or RS-232 cable.  If using the RS-232 cable, it is necessary to connect the power supply cord. 4) The LED for power indication on 3656 will become solid red. 5) The scanner LED will be flashing red during charging. When the charging is done, the LED will turn off. When charging error occurs, the LED will turn solid red. 6) The LED for communications on 3656 will first become solid blue while initializing. Refer to the table above for details on different stage of communications.   Warning:  It is recommended that the charging devices be operated at room temperature (18°C to 25°C) for optimal performance. The charging devices will not charge the battery when the temperature exceeds 40°C.  The two pivot bolts need to be tightened, or charging error may occur.
6 Enter Setup 1560 Series Barcode Scanner User Guide  INSIDE THE PACKAGE The items included in the package may be different, depending on your order. Save the box and packaging material for future use in case you need to store or ship the scanner.  Barcode Scanner (1560 or 1562)  BT Base (3656)  Rechargeable Li-ion battery  Product CD Note: The CD-ROM includes this manual and Windows-based ScanMaster software for configuration.  PRODUCT HIGHLIGHTS  Small-form-factor and built tough to survive drop test  Extremely low power consumption  Firmware upgradeable  Supports most popular barcode symbologies, including GS1-128 (EAN-128), GS1 DataBar (RSS), etc.  Supports negative barcodes  Supports different scan modes, including Aiming Mode and Multi-Barcode Mode  User feedback via LED indicator and beeper  Beeping tone and duration programmable for Good Read  512 KB flash memory for Memory Mode operation, storing up to 32,768 scans based on EAN-13 barcodes  Provides up to 4 KB SRAM for reserve buffer while getting out of range over a wireless personal area network (WPAN), storing up to 256 scans based on EAN-13 barcodes  Capable of transmitting scanned data, emulating a serial cable (BT SPP) or as keyboard input (BT HID), to a notebook computer or PDA with Bluetooth® wireless technology  Programmable parameters include data output format, editing format, symbologies, etc.
    7 Update  The configuration of the scanner can be done by reading the setup labels contained in this manual or via the ScanMaster software. This section describes the procedure of configuring the scanner by reading the setup barcodes and provides some examples for demonstration. Configuration Mode 1. Hold down the trigger about 2 seconds to turn on the scanner. It will respond with a long beep and its LED will come on and off shortly. 2. Have the scanner read the “Enter Setup” label. It will respond with six beeps and its LED indicator will become flashing red after reading the label.   3. Have the scanner read more setup barcodes… Most of the setup barcodes are normal labels. The scanner will respond with two beeps (low-high tone). For special labels, it requires reading more than one setup barcode to complete the setting. 4. Have the scanner read the “Update” or “Abort” label. It will respond with six beeps and its LED indicator will become flashing red after reading the label. 5. The scanner will restart automatically upon reading the “Update” or “Abort” label. It will respond with a long beep and its LED will come on and off shortly.   Note: Refer to Appendix II Host Serial Commands for how to configure the 3656 stand by having the scanner read 3656-related setup labels or using serial commands.  QUICK START
8 Enter Setup 1560 Series Barcode Scanner User Guide  Working Mode Upon powering up, the 1560/1562 scanner will try to establish a connection with 3656 or a computer with Bluetooth® wireless technology. Refer to Chapter 3 – Setting up a WPAN Connection for details. The connection between the scanners and 3656 is made easy and reliable.   Note:  If RS-232, USB Virtual COM or BT SPP is selected for output interface, the host can directly send serial commands to configure the scanner. For example, run HyperTerminal.exe and type the 6-digit command located under each setup label. Refer to Appendix II Host Serial Commands.
    9 Update  Quick Start  ENTER CONFIGURATION MODE For the scanner to enter the configuration mode, you must have it read the "Enter Setup" label, which can be located at the bottom of almost every even page of this manual.    The scanner will respond with six beeps and its LED indicator will become flashing red after reading the label.    For configuring scanner parameters, see “Read a Setup Label” below. EXIT CONFIGURATION MODE For the scanner to exit the configuration mode, you must have it read the “Update” label, which can be located at the bottom of almost every odd page of this manual. If you want to exit the configuration mode without saving any changes, have the scanner read the “Abort” label instead.    Just like reading the “Enter Setup” label, the scanner will respond with six beeps and its LED indicator will become flashing red after reading the label. Wait for a few seconds for the scanner to restart itself.        Update Abort Enter Setup
10 Enter Setup 1560 Series Barcode Scanner User Guide  DEFAULT SETTINGS SAVE USER SETTINGS AS DEFAULTS For the scanner to keep the customized settings as user defaults, you must have it read the “Save as User Defaults” label. This is a normal label, and the scanner will respond with two beeps (low-high tone).  After reading the “Update” label, the current settings will be saved as user defaults.   RESTORE USER DEFAULTS For the scanner to restore the user defaults, which you have saved earlier, you must have it read the “Restore User Defaults” label. This is a normal label, and the scanner will respond with two beeps (low-high tone).  After reading the “Update” label, all the parameters of the scanner will return to their customized values.     RESTORE SYSTEM DEFAULTS For the scanner to restore the factory defaults, you must have it read the “Restore System Defaults” label. This is a normal label, and the scanner will respond with two beeps (low-high tone).  After reading the “Update” label, all the parameters of the scanner will return to their default values. The current connection record will be cleared as well.   Note: The system default value (if there is) for each setting is indicated by an asterisk “*”.   Save as User DefaultsRestore User DefaultsRestore System Defaults
    11 Update  Quick Start  READ A SETUP LABEL CONFIGURE PARAMETERS For most of the scanner parameters, only one read is required to set them to new values. The scanner will respond with two beeps when each parameter is set successfully.   But for a number of special parameters, multiple reads are required to complete the setting. In this case, the scanner will respond with a short beep to indicate it needs to read more setup labels. These special parameters may require reading one or more setup labels, such as  Numeric labels, say, for keyboard type, inter-character delay, length qualification  Hexadecimal labels, say, for character strings as prefix, suffix, etc.  When “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to change key status when “Normal Key” is selected for Key Type. To complete the configuration of these special parameters, it requires reading the “Validate” label, and the scanner will respond with two beeps (low-high tone) to indicate the input values are validated.
12 Enter Setup 1560 Series Barcode Scanner User Guide  The example below shows how to save your settings as “User Default” so that you may restore user defaults at a later time: Steps  Action  User Feedback if Successful 1  Power on the scanner… The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off quickly. 2  Enter the Configuration Mode…  The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will be flashing red.  3  Read a Setup label… For example,               The scanner will respond with two beeps (low-high tone) if reading a normal label. 4  Exit the Configuration Mode…     OR    Same as for Enter the Configuration Mode. 5  The scanner will automatically restart itself…  Same as for Power on the scanner. *  When any configuration error occurs... The scanner will respond with one long beep (low tone).
    13 Update  Quick Start  The example below shows how to set numeric parameters: Steps  Action  User Feedback if Successful 1  Power on the scanner... The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off quickly. 2  Enter the Configuration Mode…  The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will become flashing red.  Read a Setup label... For example,     The scanner will respond with two beeps (low-high tone) if reading a normal label. 3        The scanner will respond with one short beep if reading a special label such as “Max. Length”, indicating the setup requires reading more labels.    Read the “Decimal Value” label(s).  Refer to Appendix IV “Decimal System”      The scanner will respond with two beeps (low-high tone) when the input values are validated. 4  Exit the Configuration Mode…   OR     Same as for Enter the Configuration Mode. 5  The scanner will automatically restart itself…  Same as for Power on the scanner. Normal label Normal label Special label Decimal label or labels
14 Enter Setup 1560 Series Barcode Scanner User Guide  The example below shows how to set string parameters: Steps  Action  User Feedback if Successful 1  Power on the scanner...  The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off quickly. 2  Enter the Configuration Mode…  The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will become flashing red.  Read a Setup label... For example,   The scanner will respond with one short beep if reading a special label such as “Prefix Code”, indicating the setup requires reading more labels.        When “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to change key status when “Normal Key” is selected for Key Type.  Refer to Appendix III 3      Read the “Hexadecimal Value” labels for the desired character string. For example, read “2” and “B” for the scanner to prefix the character “+”.  Refer to Appendix IV “Hexadecimal System”   The scanner will respond with two beeps (low-high tone) when the input values are validated. 4  Exit the Configuration Mode…   OR     Same as for Enter the Configuration Mode. 5  The scanner will automatically restart itself…  Same as for Power on the scanner.  Special label Hexadecimal labels
    15 Update  Quick Start  LIST THE CURRENT SETTINGS The current settings of all scanner parameters can be sent to the host computer for user inspection. The listing includes ten pages as shown below. You can select the page of interest by having the scanner read the “List Page x” label. The scanner will respond with two beeps (low-high tone) and send the selected page to the host immediately.   List settings regarding Firmware Version, Serial Number, Interface, Buzzer, and Other Scanner Parameters   List settings regarding Prefix, Postfix, and Length Code Setting   List settings regarding Code ID   List settings regarding: Readable Symbologies   List settings regarding Symbology Parameters (1/3)   List settings regarding Symbology Parameters (2/3)   List settings regarding Symbology Parameters (3/3) List Page 1 List Page 2 List Page 3 List Page 4 List Page 5 List Page 6 List Page 7
16 Enter Setup 1560 Series Barcode Scanner User Guide    List settings regarding Editing Format 1   List settings regarding Editing Format 2   List settings regarding Editing Format 3   List settings regarding Editing Format 4   List settings regarding Editing Format 5  List Page 8 List Page 9 List Page 10 List Page 11 List Page 12
    17 Update  This chapter explains the features and usage of the barcode scanner.   IN THIS CHAPTER 1.1 Battery..................................................................... 17 1.2 Memory.................................................................... 19 1.3 LED Indicator ............................................................ 22 1.4 Beeper ..................................................................... 24 1.5 Send "NR" to Host ..................................................... 28 1.6 Scan Modes .............................................................. 29 1.7 Scanner Time-out ...................................................... 34 1.8 Delay between Re-read............................................... 35 1.9 Effective Decoding Area .............................................. 36 1.10 Auto-Sense Mode (1560 Only) .................................. 38 1.11 CCD Sensor Always Active (1560 Only)  ...................... 39 1.12 Negative Barcodes ................................................... 39 31.13 Symbologies Supported ............................................ 40 1.1 BATTERY The scanner is powered by a rechargeable 3.7 V/800 mAh Li-ion battery, and it takes approximately 3 hours to charge the battery to full (from the power adaptor). However, the charging time may vary by working condition. For intensive data collection, you may purchase a spare battery for non-stop operation. Note: The scanner can be configured to save battery power. Refer to settings of “Auto Power Off”, “CCD Sensor Always Active”, “Sniff Mode”, as well as “Low Battery Alarm”. 1.1.1 HOW TO OPERATE THE SCANNER Turn on the scanner… After installing the battery, hold down the trigger for about 2 seconds. The scanner will respond with a long beep (high tone), and its LED will become solid red and go off quickly. Turn off the scanner… Remove the battery directly or let it turn off automatically in specific circumstances.   Chapter 1 UNDERSTANDING THE BARCODE SCANNER
18 Enter Setup 1560 Series Barcode Scanner User Guide  1.1.2 AUTO POWER OFF Specify the time interval (1~254 min.; 0= Disable) for the scanner to automatically turn off in the following circumstances. By default, it is set to 10 minutes. If this feature is not desired, set it to 0. Auto Power Off before establishing a WPAN connection successfully... 1. The scanner will stay active for 2 minutes for the following scenarios. Its CPU is running at full speed, and the LED is flashing blue (On/Off ratio 0.5 s: 0.5 s).   (a) waiting for a connection request from the host (BT SPP)   (b) trying to connect to the host (BT HID) (c) trying to connect to 3656 2. If it fails to connect within 2 minutes, the scanner will become inactive to save power for the remaining period of time (the specified value minus 2 minutes). Its CPU is running at low speed, and the LED is flashing red (On/Off ratio 0.3 s: 2.5 s).   Press the trigger to wake up the scanner when it becomes inactive, and the scanner will stay active for 2 minutes again. 3. If it fails to connect again and again, and finally stays inactive until the specified time interval has elapsed, the scanner will automatically turn off in order to conserve battery power. Hold down the trigger for about 2 seconds to turn it on. For scenarios (a) and (b) in step 1, on your computer you will have to search for the scanner again. Auto Power Off after establishing a WPAN connection successfully... Once a WPAN connection is established successfully, the LED is flashing blue (On/Off ratio 0.02 s: 3 s). If the scanner is idle during the specified time interval for Auto Power Off, it will automatically turn off when the time is up. You will hear three short beeps, tone descending from high to low. For BT HID or SPP, there is no transition from full CPU speed to low CPU speed. However, when connecting with 3656, the scanner will go through the transition in order to save power.  For BT HID, the scanner will resume connection with the host upon powering on again, as long as the host application is running. You will hear three short beeps, tone ascending from low to high. If the scanner fails to resume connection, it will try every 5 seconds to re-connect to the host unless you have the scanner read the “Reset Connection” label.  For BT SPP, the scanner must wait for the host to re-connect.  With the use of 3656, the scanner will try re-connecting to 3656 unless you turn off the scanner.     1) Read the label above to specify the time interval before the scanner automatically turns off. 2) Read the “Decimal Value” label on page 187. For example, read “1” and “5” for the scanner to automatically turn off after being idle for 15 minutes.   3) Read the “Validate” label on the same page to complete this setting.   Auto Off after 0~254 minutes (*10)
    19 Update  Chapter 1   Understanding the Barcode Scanner  1.2 MEMORY The collected data can be sent back to a host computer one by one via the WPAN connection or stored in flash memory when the scanner is set to Memory mode. 1.2.1 TRANSMIT BUFFER By default, transmit buffer is enabled and for use when the scanner is out of range. Upon reading a barcode successfully within range, the scanner responds with one short beep (high tone) and its LED indicator becomes solid green and goes off quickly. However, the host computer may not receive the data immediately if getting out of range. With the 4 KB transmit buffer, the scanner can ignore the transmission status and keep on reading barcodes until the buffer is full.  When transmit buffer is enabled and the scanner is out of range, the scanner will respond with two short beeps, high-low tone, upon reading a barcode successfully. When transmit buffer is full, the scanner will respond with one long beep (low tone) and its LED indicator will become solid red and go off quickly. You are advised to get back to range.  When transmit buffer is disabled and the scanner is out of range, the scanner will respond with one long beep (low tone) and its LED indicator will become solid red and go off quickly. You are advised to get back to range.     Note:  The 4 KB transmit buffer on the scanner can hold as many as 256 scans based on EAN-13 barcodes. Data will be cleared out once the scanner is turned off or running out of battery power!  Enable Transmit Buffer* Disable Transmit Buffer
20 Enter Setup 1560 Series Barcode Scanner User Guide  1.2.2 MEMORY MODE The scanner keeps 512 KB flash memory for memory mode operation. When the scanner is in memory mode, it means a WPAN connection is disabled.       Warning:  No WPAN connection is allowed unless the memory mode is disabled.  Memory Data Delay You may set a delay between each data record while transmitting data back to the server.        Enable Memory Mode *Disable Memory Mode*None 1 sec 2 sec 500 ms 250 ms
    21 Update  Chapter 1   Understanding the Barcode Scanner       Send Data The 512 KB flash memory on the scanner can store up to 32,768 scans based on EAN-13 barcodes. When it is used up, the scanner will respond with two short beeps (high-low tone) as a warning. You are advised to send data to the server immediately by having the scanner read the label below.     Clear Data & Confirm Even though data has been sent back to the server, the flash memory is still occupied unless you erase the memory by having the scanner read two labels – “Clear Data” and “Confirm”. 1. Read the “Clear Data” label to clear the flash memory. 2. Read the “Confirm” label to confirm the action.       3 sec 5 sec 8 sec Send DataClear Data Confirm
22 Enter Setup 1560 Series Barcode Scanner User Guide  1.3 LED INDICATOR The triple-color LED on top of the scanner is used to provide user feedback. For example, the LED becomes solid red and goes off quickly upon powering on or running out of transmit buffer. You may tell the difference by the beeps – you will hear a long beep of high tone when powering on the scanner, and a long beep of low tone when the transmit buffer becomes full. Scanner LED  Meaning Red, flashing    Charging (On/Off ratio 0.5 s: 0.5 s) Red, solid   Charging error Red, on-off      Power on, with one long beep (high tone, LED on for 1 second)  Data saved to buffer when transmit buffer is enabled and the scanner is out of range, with two short beeps (high-low tone)  Transmit buffer full, with one long beep (low tone)  Transmit buffer disabled, with one long beep (low tone)  Memory full in memory mode, with two short beeps (high-low tone)   Green, on-off Good Read, with one short beep (high tone) and beeper pitch and duration programmable  Blue, flashing   First, flashing blue (On/Off ratio 0.5 s: 0.5 s) for two minutes indicates the scanner is waiting for connection, and goes off if no connection is established, then flashing red (On/Off ratio 0.3 s: 2.5 s) indicates the scanner is inactive. It is ready for connection only while the LED is flashing blue —  SPP: waiting host to connect  HID: trying to connect to host  Using 3656: trying to connect to 3656 Red, flashing    Flashing red (On/Off ratio 0.3 s: 2.5 s) indicates the scanner is inactive and its CPU running at low speed to save power —  No WPAN connection is established after waiting for two minutes  Blue, flashing   Flashing blue (On/Off ratio 0.1 s: 0.1 s) indicates the scanner receives a PIN code request from host (flashing more quickly than waiting connection).  Blue, flashing   Flashing blue (On/Off ratio 0.02 s: 3 s) indicates the scanner has established a WPAN connection successfully.  Blue, flashing Green, flashing Flashing blue and green (On/Off ratio 0.1 s: 0.1 s) indicates an error occurs while entering the PIN code. Press the trigger to get ready for re-connecting. Red, flashing    Configuration Mode (On/Off ratio 0.5 s: 0.5 s)
    23 Update  Chapter 1   Understanding the Barcode Scanner  1.3.1 GOOD READ LED     1.3.2 GOOD READ LED DURATION By default, the Good Read LED stays on for 40 milliseconds. Specify a value, ranging from 1 to 254 in units of 10 milliseconds.    1) Read the label above to specify the time interval before the Good Read LED goes off. 2) Read the “Decimal Value” label on page 187. For example, read “1” and “5” for the Good Read LED to go off after 150 milliseconds.   3) Read the “Validate” label on the same page to complete this setting.       *Enable Good Read LED Disable Good Read LEDGood Read LED Time-Out after 0.01~2.54 seconds (*40 ms)
24 Enter Setup 1560 Series Barcode Scanner User Guide  1.4 BEEPER The scanner has a buzzer to provide user feedback in various operating conditions. Beeping  Meaning One long beep, high tone  Power on, with red LED on (1 second) and off quickly One short beep, high tone (programmable, default to 4 KHz) Good Read, with green LED on and off quickly Six short beeps, high-low tone repeats three times  Enter Configuration Mode, with red LED flashing  Exit Configuration Mode Two short beeps, low-high tone  Setup label read successfully One short beep, high tone   More setup label required  Input PIN code  Clear PIN code One short beep, low tone  More barcodes required to complete the “output sequence” requirements of Multi-Barcode Editor, with green LED on and off quickly (Upon completion, same as Good Read.) One long beep, low tone   Transmit buffer full, with red LED on and off quickly  Transmit buffer disabled, with red LED on and off quickly  Configuration error (Wrong label…)  PIN code input error  Reject random PIN request  Fail to send data in memory mode Two short beeps, high-low tone   Data saved to buffer when transmit buffer is enabled and the scanner is out of range, with red LED on and off quickly  Memory Mode – Memory full, with red LED on and off quickly Two long beeps, high-low tone  Multi-Barcode Mode – Buffer full Three short beeps, tone ascending from low to high  WPAN connection established, with blue LED flashing  WPAN connection resumed, with blue LED flashing Three short beeps, tone ascending from high to low WPAN connection out of range or suspended
    25 Update  Chapter 1   Understanding the Barcode Scanner  1.4.1 BEEPER VOLUME                     Mute Medium Volume*Maximum VolumeMinimum Volume
26 Enter Setup 1560 Series Barcode Scanner User Guide  1.4.2 GOOD READ BEEP Frequency    Duration     8 kHz  * 4 kHz  2 kHz  1 kHz  *Shortest  Longer Longest Shorter
    27 Update  Chapter 1   Understanding the Barcode Scanner  1.4.3 LOW BATTERY ALARM By default, it will activate the beeper to give a warning when the battery charge gets low.                                        * Low Battery AlarmNo Alarm
28 Enter Setup 1560 Series Barcode Scanner User Guide  1.5 SEND “NR” TO HOST The scanner can send the “NR” string to the host to notify the No Read event.                                      Enable *Disable
    29 Update  Chapter 1   Understanding the Barcode Scanner  1.6 SCAN MODES Different scan modes are supported – select the scan mode that best suits the requirements of a specific application. Refer to the comparison table below.  Scan Mode  Start to Scan  Stop Scanning  Always Press trigger once Hold trigger Press trigger twice Release trigger Press trigger once Barcode being read Timeout Continuous mode          Test mode          Laser mode            Auto Off mode           Auto Power Off mode         Aiming mode             Multi-Barcode  mode         Alternate mode           Note:  By default, the scan mode is set to Laser mode.
30 Enter Setup 1560 Series Barcode Scanner User Guide  1.6.1 CONTINUOUS MODE The scanner is always scanning.  After a successful decoding, the removal of barcode is required. It is not allowed to proceed to decode until the decoding delay time has passed.  To decode the same barcode repeatedly, move away the barcode and put it back again and again for scanning. Note:  Refer to “Delay between Re-read”.    Decoding Delay Set the time interval between each decoding.        Continuous Mode*Disable 0.5 sec 1 sec 2 sec
    31 Update  Chapter 1   Understanding the Barcode Scanner  1.6.2 TEST MODE The scanner is always scanning.  Capable of decoding the same barcode repeatedly without removing it, for testing purpose.    1.6.3 LASER MODE The scanner will start scanning once the trigger is hold down.  The scanning won't stop until (1) a barcode is decoded, (2) the pre-set timeout expires, or (3) you release the trigger. Note:  Refer to “Scanning Timeout”.    1.6.4 AUTO OFF MODE The scanner will start scanning once the trigger is pressed.  The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout expires. Note:  Refer to “Scanning Timeout”.     Test Mode*Laser ModeAuto Off Mode
32 Enter Setup 1560 Series Barcode Scanner User Guide  1.6.5 AUTO POWER OFF MODE The scanner will start scanning once the trigger is pressed.  The scanning won't stop until the pre-set timeout expires, and, the pre-set timeout period re-counts after each successful decoding. Note:  Refer to “Delay between Re-read” and “Scanning Timeout”.    1.6.6 AIMING MODE The scanner will aim at a barcode once the trigger is pressed, and start scanning when the trigger is pressed again within one second.  The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout expires.    Aiming Timeout You can limit the aiming time interval (1~15). By default, the scanner time-out is set to 1 second.     1. Read the label above to specify the time interval before aiming ends. (It is set to 1 by default.) 2. Read the “Decimal Value” label on page 187. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 10 seconds.   3. Read the “Validate” label on the same page to complete this setting.  Auto Power Off ModeAiming ModeAiming Time-Out after 1~15 seconds (*1)
    33 Update  Chapter 1   Understanding the Barcode Scanner  1.6.7 MULTI-BARCODE MODE The scanner will be scanning as long as the trigger is held down, capable of decoding not only one single barcode but a concatenation of unique barcodes.  The scanning won't stop until you release the trigger.    Note: (1) A barcode is considered unique when its Code Type or data is different from others.            (2) Multi-Barcode Mode has nothing to do with the Multi-Barcode Editor. 1.6.8 ALTERNATE MODE The scanner will start scanning once the trigger is pressed  The scanning won't stop until you press the trigger again.       Multi-Barcode ModeAlternate Mode
34 Enter Setup 1560 Series Barcode Scanner User Guide  1.7 SCANNING TIMEOUT Specify the scanning time interval (1~254 sec.; 0= Disable) when the scan mode is set to any of the following –    Laser mode  Auto Off mode  Auto Power Off mode  Aiming mode     1) Read the label above to specify the time interval before the scan engine times out. 2) Read the “Decimal Value” label on page 187. For example, read “1” and “5” for the scanner to automatically shut down after being idle for 15 seconds.   3) Read the “Validate” label on the same page to complete this setting.  Scanner Time-Out after 0~254seconds (*10)
    35 Update  Chapter 1   Understanding the Barcode Scanner  1.8 DELAY BETWEEN RE-READ This is also referred to as the “Blocking Time”, which is used to prevent the scanner from accidentally reading the same barcode twice when the scan mode is set to any of the following –    Continuous mode  Auto Power Off mode  Alternate mode           100 ms 200 ms 800 ms * 400 ms 2 sec 3 sec 5 sec 1 sec
36 Enter Setup 1560 Series Barcode Scanner User Guide  1.9 EFFECTIVE DECODING AREA By default, the effective decoding area is 100% covered by the scanned area. However, you may narrow down the decoding area to prevent reading the wrong barcode when a number of barcodes are printed closely. The scanner will only read barcodes that appear in the effective decoding area. Read the label “Centering On” and specify the percentage to narrow down the decoding area. For example, read “Left 10%” and then “Right 30%” for the scanner to decode barcode “A” only.    1.9.1 POSITIONING WINDOW   1.9.2 ADJUSTING WINDOW Percentage for Left Half   Centering On*Centering Off*Left 50%
    37 Update  Chapter 1   Understanding the Barcode Scanner     Percentage for Right Half       Left 20% Left 10% Left 30% Left 40% Right 10% Right 20% *Right 50% Right 40% Right 30%
38 Enter Setup 1560 Series Barcode Scanner User Guide  1.10 AUTO-SENSE MODE (1560 ONLY) This mode is only available when you want to seat the scanner in the Auto-Sense Stand. When you enable this mode, it will force the scanner to apply Laser mode as the scan mode. However, it works differently from the original Laser mode. Now the scanner will be scanning as long as it is seated in the Auto-Sense Stand, as shown below. Whenever a barcode is brought within range, the scanner will be able to decode it. Warning:  When you disable this mode later, the scan mode remains unchanged. If Laser mode is not desired, proceed to select a scan mode best suits your application.  Note:  For Auto-Sense mode to work, you must connect (1) the power supply cord and (2) the interface cable to the Auto-Sense Stand. USB power is insufficient.  When the ambient light is too dim to activate the sensor, you may have the scanner read the “High Sensitivity” label to improve performance.    *Disable Enable *Normal High Sensitivity
    39 Update  Chapter 1   Understanding the Barcode Scanner  1.11 CCD SENSOR ALWAYS ACTIVE (1560 ONLY) This feature is used to keep the CCD sensor always active so that the scanner can decode more efficiently. However, you may disable it in order to save battery power.    1.12 NEGATIVE BARCODES Normally, barcodes are printed with the color of the bars darker than that of the spaces. But for negative barcodes, they are printed in the opposite sense just like negative films. The spaces of negative barcodes are printed with a color darker than that of the bars. You can configure the scanner to be able to read negative barcodes.                   Enable *Disable *Enable Disable
40 Enter Setup 1560 Series Barcode Scanner User Guide  1.13 SYMBOLOGIES SUPPORTED Most of the popular barcode symbologies are supported, as listed below. Each can be individually enabled or disabled. The scanner will automatically discriminate and recognize all the symbologies that are enabled. Refer to Chapter 4 Changing Symbology Settings for details of each symbology. Symbologies Supported: Enable/Disable  CCD Scan Engine Codabar  Enabled Code 93  Enabled MSI   Disabled Plessey   Disabled Telepen   Disabled Code 128  Enabled GS1-128 (EAN-128)    Disabled Code 128 ISBT-128  Disabled Industrial 25    Enabled Interleaved 25  Enabled Code 2 of 5 Matrix 25    Disabled Code 39  Enabled Italian Pharmacode      Disabled Code 3 of 9 French Pharmacode    Disabled EAN-8 Enabled EAN-8 Addon 2    Disabled EAN-8 Addon 5    Disabled EAN-13 Enabled EAN-13 & UPC-A Addon 2    Disabled EAN-13 & UPC-A Addon 5    Disabled ISBN  Disabled UPC-E0 Enabled UPC-E1  Disabled UPC-E Addon 2    Disabled UPC-E Addon 5    Disabled EAN/UPC UPC-A Enabled GS1 DataBar Omnidirectional (RSS-14)    Disabled GS1 DataBar Limited (RSS Limited)    Disabled GS1 DataBar (RSS) GS1 DataBar Expanded (RSS Expanded)    Disabled
    41 Update  Chapter 1   Understanding the Barcode Scanner  1.13.1 READ REDUNDANCY FOR ALL SYMBLOGIES Select the level of reading security. For example,  If "No Redundancy" is selected, one successful decoding will make the reading valid and induce the "READER Event".  If "Three Times" is selected, it will take a total of four consecutive successful decodings of the same barcode to make the reading valid. The higher the reading security is (that is, the more redundancy the user selects), the slower the reading speed gets.   It is obvious that the more redundancy you select, the higher the reading security is, and thus, the slower the reading speed becomes. You will have to compromise between reading security and decoding speed.                     *No RedundancyTwo Times  One Time Three Times
42 Enter Setup 1560 Series Barcode Scanner User Guide  1.13.2 ADDON SECURITY FOR UPC/EAN BARCODES You may like to enforce read redundancy (0~30 times) on UPC/EAN barcodes with addons only. Note: UPC/EAN Addon 2 and Addon 5 must be enabled individually for this setting to take effect.   1) Read the label above to specify the read redundancy when missing add-ons while scanning UPC/EAN barcodes. (It is set to 0 by default.)       2) Read the “Decimal Value” label on page 187. For example, read “1” and “2” for the scanner to re-read the barcode for 12 times.   3) Read the “Validate” label on the same page to complete this setting.    Addon Security Level (*0 ~ 30)
    43 Update  In order to establish a proper connection between your computer and the scanner, we suggest that you follow these instructions –   1) Install batteries and hold down the trigger for about 2 seconds to turn on the scanner. 2) Have the scanner read the “Enter Setup” label to enter the configuration mode. 3) Have the scanner read the associated label to activate the desired interface. See the following sections for output interfaces supported. 4) Have the scanner read the labels for related settings. 5) Have the scanner read the “Update” label to exit the configuration mode. 6) Turn on your computer or laptop and establish a WPAN connection with the scanner.  Refer to Chapter 3 – Setting up a WPAN Connection. Note:  By default, the output interface is set to “BT HID”.    IN THIS CHAPTER 32.1 BT HID..................................................................... 44 32.2 BT SPP ..................................................................... 51 2.3 Keyboard Wedge via 3656 .......................................... 53 2.4 RS-232 via 3656........................................................ 61 2.5 USB HID via 3656...................................................... 66 2.6 USB Virtual COM via 3656........................................... 73             Chapter 2 SELECTING OUTPUT INTERFACE
44 Enter Setup 1560 Series Barcode Scanner User Guide  2.1 BT HID For BT HID, refer to Chapter 3 – Setting up a WPAN Connection for related connection settings. Run any text editor on your computer, and the scanned data will be transmitted to the computer. HID Settings  Defaults Keyboard Type  PCAT (US) Digits Layout  Normal Capital Lock Type  Normal Capital Lock State  Off Alphabets Transmission  Case-sensitive Digits Transmission  Alphanumeric keypad Inter-Function Delay  0 (ms) Send “NR” to Host  Disable  2.1.1 ACTIVATE BT HID & SELECT KEYBOARD TYPE When BT HID interface is activated, you will have to select a keyboard type to complete this setting. By default, BT HID is activated on the scanner, and the keyboard type is set to PCAT (US).      1) Read the label above to activate BT HID and select a keyboard type.  2) Read the “Decimal Value” label on page 187. Refer to the table below for the number of desired keyboard type.   3) Read the “Validate” label on the same page to complete this setting. Activate BT HID & Select Keyboard Type …
    45 Update  Chapter 2   Selecting Output Interface  BT HID By default, the keyboard type is set to PCAT (US). The following keyboard types are supported for BT HID or USB HID when using 3656 with the USB cable provided —   No.  Keyboard Type  No. Keyboard Type 64  PCAT (US)  70  PCAT (UK) 65  PCAT (French)  71  PCAT (Belgium) 66  PCAT (German)  72  PCAT (Spanish) 67  PCAT (Italy)  73  PCAT (Portuguese) 68  PCAT (Swedish)  74  PS55 A01-2 (Japanese) 69 PCAT (Norwegian)  75 User-defined table   2.1.2 RESET CONNECTION For BT HID, you can only have the scanner connected to one computer at a time. If you want to connect the scanner to another host, you must have it read the “Reset Connection” label so that the current connection record will be cleared. Then, the scanner will restart itself automatically. Go through the whole process in 3.2.3 Connect to Dongle to establish a new connection.  Note: The “Restore System Defaults” label will have the current connection record cleared as well.   Reset Connection
46 Enter Setup 1560 Series Barcode Scanner User Guide  2.1.3 KEYBOARD SETTINGS  Digits Layout  Capital Lock Type  Capital Lock Setting  Alphabets Transmission  Digits Transmission Note:  BT HID does not support these functions on PDAs – (1) Capital Lock Setting: Auto Detection (2) Digits Transmission: Numeric Key Digits Layout Select a proper layout that matches the alphabets layout. The scanner will make adjustments according to this setting. Options  Description Normal  Depends on the [Shift] key or [Shift Lock] setting Lower Row  For QWERTY or QWERTZ keyboard Upper Row  For AZERTY keyboard     Note:  This setting is to be used with the Character Substitution setting when support to certain keyboard types (languages) is unavailable but required. Capital Lock Type & Setting In order to send the alphabets with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being transmitted.  *Normal Lower Row Upper Row
    47 Update  Chapter 2   Selecting Output Interface  Cap Lock Type  Description Normal Normal type Capital Lock  When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys. Shift Lock  When enabled, the keys of alphabetic characters will be interpreted as capital letters. In addition, this affects the number or punctuation keys.     Capital Lock State  Description Capital Lock OFF  Assuming  that the status of Caps Lock on the keyboard is OFF, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Capital Lock ON  Assuming that the status of Caps Lock on the keyboard is ON, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission).  Refer to the Capital Lock Type above. Auto Detection The scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted; transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission).  This setting is not supported on PDAs.     *Capital Lock OFF Capital LockShift Lock *Normal
48 Enter Setup 1560 Series Barcode Scanner User Guide   Alphabets Transmission By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of Caps Lock on the keyboard only.      Auto DetectionCapital Lock ONRefer to 5.1 Letter Case.
    49 Update  Chapter 2   Selecting Output Interface     Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you wish to use the keys on the numeric keypad.     Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard should be "ON". This setting is not supported on PDAs.    Ignore Case*Case-sensitive *Alphanumeric Key Numeric Key
50 Enter Setup 1560 Series Barcode Scanner User Guide  2.1.4 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Value  Delay Time  Value  Delay Time 0  Disable  195 ~ 204  200 millisecond 1 ~ 14  10 millisecond  205 ~ 214  210 millisecond 15 ~ 24  20 millisecond  215 ~ 224  220 millisecond 25 ~ 34  30 millisecond  225 ~ 234  230 millisecond 35 ~ 44  40 millisecond  235 ~ 244  240 millisecond 45 ~ 54  50 millisecond  245 ~ 254  250 millisecond … …        1) Read the label above to specify the inter-function delay.       2) Read the “Decimal Value” label on page 187 for the desired inter-function delay (millisecond).  3) Read the “Validate” label on the same page to complete this setting.    Inter-Function Delay … (*0 ~ 254)
    51 Update  Chapter 2   Selecting Output Interface  2.2 BT SPP For BT SPP, refer to Chapter 3 – Setting up a WPAN Connection for related connection settings. For example, run HyperTerminal.exe on your computer, and the scanned data will be transmitted to the computer. 2.2.1 ACTIVATE BT SPP  2.2.2 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Value  Delay Time  Value  Delay Time 0  Disable  195 ~ 204  200 millisecond 1 ~ 14  10 millisecond  205 ~ 214  210 millisecond 15 ~ 24  20 millisecond  215 ~ 224  220 millisecond 25 ~ 34  30 millisecond  225 ~ 234  230 millisecond 35 ~ 44  40 millisecond  235 ~ 244  240 millisecond 45 ~ 54  50 millisecond  245 ~ 254  250 millisecond … …        1) Read the label above to specify the inter-function delay.       2) Read the “Decimal Value” label on page 187 for the desired inter-function delay (millisecond).  3) Read the “Validate” label on the same page to complete this setting. Activate Bluetooth SPPInter-Function Delay … (*0 ~ 254)
52 Enter Setup 1560 Series Barcode Scanner User Guide  2.2.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data three more times. If all the attempts fail without any notification, data loss will occur.    1) Read the label above to specify the time interval for the scanner to send data and wait for a response from the host.             2) Read the “Decimal Value” label on page 187. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 1 second.   3) Read the “Validate” label on the same page to complete this setting. ACK/NAK Error Beep    Note:  We suggest you to enable the error beep so that you will be notified of such data loss and have the scanner re-read data.      ACK/NAK Time-Out after … (*0 ~ 99)Enable Error Beep *Disable Error Beep
    53 Update  Chapter 2   Selecting Output Interface  2.3 KEYBOARD WEDGE VIA 3656 The Y cable allows you to connect the scanner via 3656 to the keyboard input port of PC and you may join the keyboard as well. The scanned data will be transmitted to the host keyboard port as if it is manually entered via the keyboard. For example, run a text editor on your computer to receive the data. Keyboard Wedge Settings  Defaults Keyboard Type  PCAT (US) Alphabets Layout  Normal Digits Layout  Normal Capital Lock Type  Normal Capital Lock State  Off Alphabets Transmission  Case-sensitive Digits Transmission  Alphanumeric keypad Alternate Composing  No Inter-Character Delay  0 (ms) Inter-Function Delay  0 (ms) Send “NR” to Host  Disable Laptop Support  Disable 2.3.1 ACTIVATE KEYBOARD WEDGE & SELECT KEYBOARD TYPE When Keyboard Wedge interface is activated, you will have to select a keyboard type to complete this setting.    1) Read this label above to activate Keyboard Wedge and select a keyboard type.   2) Read the “Decimal Value” label on page 187. Refer to the table below for the number of desired keyboard type.   3) Read the “Validate” label on the same page to complete this setting. Activate & Select Keyboard Type…
54 Enter Setup 1560 Series Barcode Scanner User Guide  Keyboard Wedge via 3656 By default, the keyboard type is set to PCAT (US). The following keyboard types are supported when using 3656 with the keyboard wedge cable provided — No.  Keyboard Type  No. Keyboard Type 1  PCAT (US)  16  PS55 001-2 2  PCAT (French)  17  PS55 001-82 3  PCAT (German)  18  PS55 001-3 4  PCAT (Italian)  19  PS55 001-8A 5  PCAT (Swedish)  20  PS55 002-1, 003-1 6  PCAT (Norwegian)  21  PS55 002-81, 003-81 7  PCAT (UK)  22  PS55 002-2, 003-2 8  PCAT (Belgium)  23  PS55 002-82, 003-82 9  PCAT (Spanish)  24  PS55 002-3, 003-3 10  PCAT (Portuguese)  25  PS55 002-8A, 003-8A 11  PS55 A01-1  26  IBM 3477 Type 4 (Japanese) 12  PS55 A01-2 (Japanese)  27  PS2-30 13  PS55 A01-3  28  IBM 34XX/319X, Memorex Telex 122 Keys 14 PS55 001-1  29 User-defined table 15 PS55 001-81      2.3.2 KEYBOARD SETTINGS Alphabets Layout By default, the alphabets layout is set to normal mode, also known as the standard English layout. Select French or German keyboard layout if necessary. The scanner will make adjustments when sending the "A", "Q", "W", "Z", "Y", and "M" characters according to this setting.   *Normal AZERTY QWERTZ
    55 Update  Chapter 2   Selecting Output Interface  US Keyboard Style – Normal QWERTY layout, which is normally used in western countries.   Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters. French Keyboard Style – AZERTY French layout; see below for French Keyboard Style.   Select “Upper Row” for the “Digits Layout” setting for the lower row is for special characters. German Keyboard Layout – QWERTZ German layout; see below for German Keyboard Style.   Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters.
56 Enter Setup 1560 Series Barcode Scanner User Guide  Note:  This setting only works when the keyboard type selected is US keyboard, such as PCAT (US). The Alphabets Layout and Digits Layout setting must match your keyboard. Digits Layout Select a proper layout that matches the alphabets layout. The scanner will make adjustments according to this setting. Options  Description Normal  Depends on the [Shift] key or [Shift Lock] setting Lower Row  For QWERTY or QWERTZ keyboard Upper Row  For AZERTY keyboard     Note:  This setting is meant to be used with the Alphabets Layout; and perhaps with the Character Substitution setting when support to certain keyboard types (languages) is unavailable but required. Capital Lock Type & Setting In order to send the alphabets with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being transmitted. Cap Lock Type  Description Normal Normal type Capital Lock  When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys. Shift Lock  When enabled, the keys of alphabetic characters will be interpreted as capital letters. In addition, this affects the number or punctuation keys. *Normal Lower Row Upper Row
    57 Update  Chapter 2   Selecting Output Interface      Capital Lock State  Description Capital Lock OFF  Assuming that the status of Caps Lock on the keyboard is OFF, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Capital Lock ON  Assuming that the status of Caps Lock on the keyboard is ON, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission).  Refer to the Capital Lock Type above. Auto Detection  The scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted; transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission).       *Capital Lock OFF Capital LockShift Lock *Normal Auto DetectionCapital Lock ON
58 Enter Setup 1560 Series Barcode Scanner User Guide  Alphabets Transmission By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of Caps Lock on the keyboard only.      Ignore Case*Case-sensitive Refer to 5.1 Letter Case.
    59 Update  Chapter 2   Selecting Output Interface  Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you wish to use the keys on the numeric keypad.    Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard should be "ON". ALT Composing By default, Alternate key composing is disabled. Select [Yes] to allow emulating Alternate key code of a specific keyboard character. For example, [Alt] + [065] will be sent to host for the character “A” regardless the keyboard type you are using.    Laptop Support By default, laptop support is disabled. It is suggested to enable this feature if you connect the wedge cable to a laptop without an external keyboard being inter-connected. *Alphanumeric Key Numeric Key*No Yes
60 Enter Setup 1560 Series Barcode Scanner User Guide    2.3.3 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be.    1) Read the label above to specify the inter-character delay.     2) Read the “Decimal Value” label on page 187 for the desired inter-character delay (millisecond).  3) Read the “Validate” label on the same page to complete this setting. 2.3.4 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be.    1) Read the label above to specify the inter-function delay.       2) Read the “Decimal Value” label on page 187 for the desired inter-function delay (millisecond).  3) Read the “Validate” label on the same page to complete this setting.  Inter-Character Delay … (*0 ~ 254)Inter-Function Delay … (*0 ~ 254)*Disable Enable
    61 Update  Chapter 2   Selecting Output Interface  2.4 RS-232 VIA 3656 Use the RS-232 cable to connect the scanner via 3656 to the serial port of PC, and connect the power supply cord. The associated RS-232 parameters must match those configured on the computer. You may run HyperTerminal.exe on your computer, and the scanned data will be transmitted to the computer. RS-232 Settings  Defaults Baud Rate, Data Bit, Parity, Stop Bit  9600 bps, 8 bits, No parity, 1 stop bit Flow Control  None Inter-Character Delay  0 (ms) Inter-Function Delay  0 (ms) Send “NR” to Host  Disable ACK/NAK Timeout  0 ACK/NAK Beep  Disable 2.4.1 ACTIVATE RS-232 INTERFACE   2.4.2 BAUD RATE      Activate RS-232 Interface*115200 bps57600 bps 38400 bps 19200 bps
62 Enter Setup 1560 Series Barcode Scanner User Guide      2.4.3 DATA BITS   2.4.4 PARITY   1200 bps 9600 bps 2400 bps 600 bps * 8 bits 7 bits *No Parity Even
    63 Update  Chapter 2   Selecting Output Interface   2.4.5 STOP BIT   2.4.6 FLOW CONTROL By default, there is no flow control in use. Select the flow control (handshake) method. Options  Description No  No flow control Scanner Ready  The scanner will activate the RTS signal upon powering on. After each good read, the scanner will then wait for the CTS signal to become active. Data will not be sent until the CTS signal becomes active. Data Ready The RTS signal will be activated after each good read. The scanner will then wait for the CTS signal to become active. Data will not be sent until the CTS signal becomes active. Inverted Data Ready  It works the same as the Data Ready flow control, except that the RTS signal level is inverted.    Odd 2 stop bits * 1 stop bit*None Scanner Ready
64 Enter Setup 1560 Series Barcode Scanner User Guide    2.4.7 INTER-CHARACTER DELAY  By default, the inter-character delay is zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be.    1) Read the label above to specify the inter-character delay.     2) Read the “Decimal Value” label on page 187 for the desired inter-character delay (millisecond).  3) Read the “Validate” label on the same page to complete this setting. 2.4.8 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be.    1) Read this label above to specify the inter-function delay.       2) Read the “Decimal Value” label on page 187 for the desired inter-function delay (millisecond).  3) Read the “Validate” label on the same page to complete this setting.  Data Ready Invert Data ReadyInter-Character Delay … (*0 ~ 254)Inter-Function Delay … (*0 ~ 254)
    65 Update  Chapter 2   Selecting Output Interface  2.4.9 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data three more times. If all the attempts fail without any notification, data loss will occur.    1) Read the label above to specify the time interval for the scanner to send data and wait for a response from the host.             2) Read the “Decimal Value” label on page 187. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 1 second.   3) Read the “Validate” label on the same page to complete this setting. ACK/NAK Error Beep    Note:  We suggest you to enable the error beep so that you will be notified of such data loss and have the scanner re-read data.   ACK/NAK Time-Out after … (*0 ~ 99)Enable Error Beep *Disable Error Beep
66 Enter Setup 1560 Series Barcode Scanner User Guide  2.5 USB HID VIA 3656 For USB HID, use the USB cable to connect the scanner via 3656 to the USB port of PC and connect the power supply cord if necessary. Run any text editor on your computer, and the scanned data will be transmitted to the computer. HID Settings  Defaults Keyboard Type  PCAT (US) Digits Layout  Normal Capital Lock Type  Normal Capital Lock State  Off Alphabets Transmission  Case-sensitive Digits Transmission  Alphanumeric keypad Inter-Function Delay  0 (ms) Send “NR” to Host  Disable  2.5.1 ACTIVATE USB HID & SELECT KEYBOARD TYPE When USB HID interface is activated, you will have to select a keyboard type to complete this setting. By default, BT HID is activated on the scanner, and the keyboard type is set to PCAT (US).      1) Read the label above to activate USB HID and select a keyboard type.   2) Read the “Decimal Value” label on page 187. Refer to the table below for the number of desired keyboard type.   3) Read the “Validate” label on the same page to complete this setting. Activate USB HID & Select Keyboard Type …
    67 Update  Chapter 2   Selecting Output Interface  USB HID via 3656 By default, the keyboard type is set to PCAT (US). The following keyboard types are supported for BT HID or USB HID when using 3656 with the USB cable provided —   No.  Keyboard Type  No. Keyboard Type 64  PCAT (US)  70  PCAT (UK) 65  PCAT (French)  71  PCAT (Belgium) 66  PCAT (German)  72  PCAT (Spanish) 67  PCAT (Italy)  73  PCAT (Portuguese) 68  PCAT (Swedish)  74  PS55 A01-2 (Japanese) 69 PCAT (Norwegian)  75 User-defined table
68 Enter Setup 1560 Series Barcode Scanner User Guide  2.5.2 KEYBOARD SETTINGS  Digits Layout  Capital Lock Type  Capital Lock Setting  Alphabets Transmission  Digits Transmission Digits Layout Select a proper layout that matches the alphabets layout. The scanner will make adjustments according to this setting. Options  Description Normal  Depends on the [Shift] key or [Shift Lock] setting Lower Row  For QWERTY or QWERTZ keyboard Upper Row  For AZERTY keyboard     Note:  This setting is to be used with the Character Substitution setting when support to certain keyboard types (languages) is unavailable but required. Capital Lock Type & Setting In order to send the alphabets with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being transmitted. Cap Lock Type  Description Normal Normal type *Normal Lower Row Upper Row
    69 Update  Chapter 2   Selecting Output Interface  Capital Lock  When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys. Shift Lock  When enabled, the keys of alphabetic characters will be interpreted as capital letters. In addition, this affects the number or punctuation keys.     Capital Lock State  Description Capital Lock OFF  Assuming that the status of Caps Lock on the keyboard is OFF, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Capital Lock ON  Assuming that the status of Caps Lock on the keyboard is ON, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission).  Refer to the Capital Lock Type above. Auto Detection The scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted; transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission).    *Capital Lock OFF Capital LockShift Lock *Normal Capital Lock ON
70 Enter Setup 1560 Series Barcode Scanner User Guide   Alphabets Transmission By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of Caps Lock on the keyboard only.    Auto Detection*Case-sensitive Refer to 5.1 Letter Case.
    71 Update  Chapter 2   Selecting Output Interface   Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you wish to use the keys on the numeric keypad.     Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard should be "ON".      *Alphanumeric Key Numeric KeyIgnore Case
72 Enter Setup 1560 Series Barcode Scanner User Guide  2.5.3 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Value  Delay Time  Value  Delay Time 0  Disable  195 ~ 204  200 millisecond 1 ~ 14  10 millisecond  205 ~ 214  210 millisecond 15 ~ 24  20 millisecond  215 ~ 224  220 millisecond 25 ~ 34  30 millisecond  225 ~ 234  230 millisecond 35 ~ 44  40 millisecond  235 ~ 244  240 millisecond 45 ~ 54  50 millisecond  245 ~ 254  250 millisecond … …        1) Read the label above to specify the inter-function delay.       2) Read the “Decimal Value” label on page 187 for the desired inter-function delay (millisecond).  3) Read the “Validate” label on the same page to complete this setting.        Inter-Function Delay … (*0 ~ 254)
    73 Update  Chapter 2   Selecting Output Interface  2.6 USB VIRTUAL COM VIA 3656 Use the USB cable to connect the scanner via 3656 to the USB port of PC and connect the power supply cord if necessary. You may run HyperTerminal.exe on your computer, and the scanned data will be transmitted to the computer. Note:  If you are using USB Virtual COM for the first time, you must install its driver from the CD-ROM. Driver version 5.3 or later is required. Please remove older versions! 2.6.1 ACTIVATE USB VIRTUAL COM  2.6.2 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Value  Delay Time  Value  Delay Time 0  Disable  195 ~ 204  200 millisecond 1 ~ 14  10 millisecond  205 ~ 214  210 millisecond 15 ~ 24  20 millisecond  215 ~ 224  220 millisecond 25 ~ 34  30 millisecond  225 ~ 234  230 millisecond 35 ~ 44  40 millisecond  235 ~ 244  240 millisecond 45 ~ 54  50 millisecond  245 ~ 254  250 millisecond … …        1) Read the label above to specify the inter-function delay.       2) Read the “Decimal Value” label on page 187 for the desired inter-function delay (millisecond).  3) Read the “Validate” label on the same page to complete this setting. Activate USB Virtual COMInter-Function Delay … (*0 ~ 254)
74 Enter Setup 1560 Series Barcode Scanner User Guide  2.6.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data three more times. If all the attempts fail without any notification, data loss will occur.    1) Read the label above to specify the time interval for the scanner to send data and wait for a response from the host.             2) Read the “Decimal Value” label on page 187. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 1 second.   3) Read the “Validate” label on the same page to complete this setting. ACK/NAK Error Beep    Note:  We suggest you to enable the error beep so that you will be notified of such data loss and have the scanner re-read data.        ACK/NAK Time-Out after … (*0 ~ 99)Enable Error Beep *Disable Error Beep
    75 Update  The 1560/1562 scanner can be configured to send data to a host computer wirelessly via the 3656 stand, or to a notebook computer or PDA with Bluetooth® wireless technology. Upon powering up, the scanner will be ready for establishing a WPAN connection.   To establish a connection via 3656 after reading “Set Connection” and “Serial No.” labels … Cable Type  Interface Option  Reference Keyboard Wedge Cable  Keyboard Wedge  Section 2.3 RS-232 Cable  RS-232  Section 2.4 USB HID  Section 2.5 USB Cable USB Virtual COM  Section 2.6  To establish a connection via a generic Bluetooth® dongle after pairing…   Interface Option  Reference BT HID  Section 2.1 BT SPP  Section 2.2   IN THIS CHAPTER 3.1 Connecting via 3656 .................................................. 76 3.2 Connecting via Bluetooth® Dongle ................................ 78  Chapter 3 SETTING UP A WPAN CONNECTION
76 Enter Setup 1560 Series Barcode Scanner User Guide  3.1 CONNECTING VIA 3656 Use the interface cable to connect the scanner via 3656 to PC. You can have up to seven scanners connected to one computer at the same time. Note:  If you are using USB Virtual COM for the first time, you must install its driver from the CD-ROM. Driver version 5.3 or later is required. Please remove older versions! 3.1.1 CONNECT TO 3656 By default, the interface of 3656 is set to “USB HID”. You can connect any scanner to 3656 by having the scanner read the two labels at the back of 3656. The scanner will respond with one beep upon reading each of the labels.  “Set Connection” label  “Serial Number” label After reading these labels, the scanner will stay active for 2 minutes trying to connect to the 3656 stand while its LED is flashing blue (On/Off ratio 0.5 s: 0.5 s). Once connected, the scanner will respond with three beeps (tone ascending from low to high), and the LED becomes flashing blue (On/Off ratio 0.02 s: 3 s). When getting out of range, the scanner will respond with three short beeps (tone descending from high to low). Read the “Set Connection” label first, and then the “Serial Number” label. If the “Set Connection” label on 3656 is illegible, try this one —  Note:  The 3656 settings will overwrite the interface-related settings on the scanners that are currently connected to 3656.        Set Connection
    77 Update  Chapter 3   Setting up a WPAN Connection  3.1.2 CHANGE INTERFACE If you want to change the interface cable of 3656, use one of the scanners to configure the interface-related settings and it will pass the new settings to 3656, which will then initialize and pass the settings to any other connected scanners. 1) Have the scanner read the “Set Connection” and “Serial Number” labels at the back of 3656. 2) Within two minutes, connect the interface cable, Keyboard Wedge, RS-232 or USB, between 3656 and your computer. For USB Virtual COM, you may need to install its driver first! 3) The scanners will connect to your computer via 3656. 4) Have one scanner read the “Enter Setup” label to enter the configuration mode. 5) Have the scanner read the desired interface label and configure its related settings –   “Activate Keyboard Wedge & Select Keyboard Type”  “Activate RS-232”  “Activate USB HID & Select Keyboard Type”  “Activate USB Virtual COM” 6) Have the scanner read the “Update” label to exit the configuration mode. 7) After the scanner resumes connection with 3656, it will pass the interface-related settings to 3656. 8) Upon receipt of the new settings, 3656 will initialize itself. 9) Updated with new settings, 3656 will pass the settings to other connected scanners.
78 Enter Setup 1560 Series Barcode Scanner User Guide  3.2 CONNECTING VIA BLUETOOTH® DONGLE 3.2.1 CHANGE INTERFACE Below is the procedure to configure the scanner before establishing a WPAN connection via a generic Bluetooth® dongle. 1) Have the scanner read the “Enter Setup” label to enter the configuration mode. 2) Have the scanner read the desired interface label –    “Activate BT HID & Select Keyboard Type”  “Activate BT SPP” 3) Have the scanner read the labels related to WPAN settings, such as Device Name Broadcasting, Authentication & PIN Code, etc. 4) Have the scanner read the “Update” label to exit the configuration mode. 5) The scanner will stay active for 2 minutes waiting for a connection request from the host (SPP) or trying to connect to the host (HID). Its CPU is running at full speed, and the LED is flashing blue (On/Off ratio 0.5 s: 0.5 s). Once connected, when getting out of range, the scanner will respond with three short beeps (tone descending from high to low).
    79 Update  Chapter 3   Setting up a WPAN Connection  3.2.2 CONFIGURE RELATED SETTINGS Sniff Mode (Power-saving) By default, this feature is enabled, meaning the scanner will listen to the wireless network at a reduced rate.    Note: When connecting more than two scanners to a notebook computer or PDA with Bluetooth® wireless technology, we suggest you to disable the power-saving setting for a more reliable connection. Device Name Broadcasting The scanner can be configured to hide itself from other devices equipped with Bluetooth® wireless technology. Simply disable the device name broadcasting setting so that it won’t be discovered by any other computer or PDA. However, broadcasting must be enabled for establishing an initial connection with the scanner. For example, you can disable device name broadcasting after successfully connecting the scanner to WorkStation1. Such connection will be maintained automatically unless the scanner is removed from the paired device list (called unpairing) by WorkStation1 or any changes made to authentication and the PIN code. If you want WorkStation2 to connect to the scanner, you will have to enable device name broadcasting first.    Note: By default, device name broadcasting is enabled (which is required for initial connection).  *Enable Disable *Enable Disable
80 Enter Setup 1560 Series Barcode Scanner User Guide  Authentication For security concerns, it is suggested that you enable authentication and specify a unique PIN code, also known as the passkey used to pair two devices before establishing a WPA connection. When any changes are made to authentication and PIN code on the scanner side, you will have to remove the scanner from the paired device list (called unpairing) and go through the whole process to re-establish the connection. The scanner allows up to 16 characters for a PIN code and provides two options for authentication: Enable Authentication with Preset PIN Have the scanner read the “Use preset PIN” label, and change the preset PIN if necessary. This means you will have to enter exactly the same string for your computer or PDA to connect to the scanner. If the PIN or passkey is incorrect, any connection attempt will be turned down by the scanner. See step 8 in 3.2.3 Connect to Dongle.   Enable Authentication with Random PIN or No Authentication By default, it is set to “No PIN or use random PIN”, which depends on the setting of the target device. (No PIN = No authentication.)             Note:  When using BT HID, some device driver may not support pre-defined PIN code for authentication. In this case, make sure you have the scanner set to “No PIN or use random PIN” before pairing. While pairing, the host PIN code will be displayed on the computer screen. Have the scanner read the setup barcode “Enter PIN Code in Decimal” or “Enter PIN Code in Hexadecimal” to input the matching PIN code. Use preset PIN *No PIN or  use random PIN Use random PIN No PIN required
    81 Update  Chapter 3   Setting up a WPAN Connection  Entering preset PIN code… 1. Read the “Use preset PIN” label to enable authentication with a preset PIN.    2. Read one of the labels to specify the PIN code, in decimal or hexadecimal.   By default, the PIN code is set to “0000”. Maximum 16 characters are allowed.                                                               3. Read the “Decimal Value” label on page 187 or the “Hexadecimal Value” label on page 188 for the desired digits or character string.   Read the “Clear PIN Code” label first if you need to re-input the PIN code.    4. Read the “Validate” label to complete this setting.          Enter PIN Code in Hexadecimal … Enter PIN Code in Decimal … Use preset PINClear PIN Code
82 Enter Setup 1560 Series Barcode Scanner User Guide  3.2.3 CONNECT TO DONGLE The procedure goes through associating devices for establishing a WPAN connection, which is pretty much the same except for the software you are using. If your computer is running Microsoft® Windows® XP Service Pack 3 (SP3) or Windows Vista® Service Pack 1 (SP1), you can use the generic software support that Windows® includes, or you can use the driver that the device manufacturer provides. Now, let’s try using the generic software support that Windows® XP Service Pack 2 includes.  BT HID Procedure By default, BT HID is activated on the scanner, and the keyboard type is set to PCAT (US). When BT HID is re-activated, you will have to select a keyboard type to complete this setting. The procedure is the same as for BT SPP. Refer to steps 1~11 below. BT SPP Procedure 1. Turn on the Bluetooth® function on your computer, running Windows XP SP2. 2. Double-click the Bluetooth® icon fro the lower right of the taskbar.   Alternatively, you may go to Control Panel > Bluetooth Devices. 3. Click [Add] to search devices nearby.
    83 Update  Chapter 3   Setting up a WPAN Connection  4. Turn on the scanner with correct WPAN settings, such as select BT SPP or BT HID, broadcasting enabled, authentication enabled, and PIN code specified, etc. Select the check box of [My device is set up and ready to be found] on your computer. 5. Click [Next].
84 Enter Setup 1560 Series Barcode Scanner User Guide  6. Wait for a few seconds for the Wizard to search available devices nearby.   The scanner will appear with its “serial number” as the device name. You may double-check the “Serial Number” label on the scanner to ensure connecting with the correct scanner. Select the target scanner. If the target scanner does not appear on the list, click [Search Again] to refresh the list. The scanner might enter Suspend Mode now, and you can press the trigger to have it active again (=discoverable). It will then stay active for 2 minutes and wait for PC to establish a connection. 7. Click [Next].
    85 Update  Chapter 3   Setting up a WPAN Connection  8. Enter the passkey for authentication, which must be exactly the same as configured for the scanner. 9. Click [Next].   Wait for a few seconds for Windows to exchange passkeys.
86 Enter Setup 1560 Series Barcode Scanner User Guide  10. Click [Finish].     Bluetooth SPP Only
    87 Update  Chapter 3   Setting up a WPAN Connection  11. Now the target scanner will be listed as shown below. You can have up to seven scanners connected to one computer at the same time.  Note:  When any changes are made to authentication and PIN code on the scanner side, or you want to change to use BT HID, it is suggested that you remove the scanner from the paired device list (called unpairing) and go through the whole process to re-establish the connection.                  Select and Remove
88 Enter Setup 1560 Series Barcode Scanner User Guide  12. Run the desired application on your computer, such as HyperTerminal.exe if using BT SPP or Notepad.exe if using BT HID. The status of the scanner listed on the device list will be updated to “Connected”, indicating the WPAN connection is established successfully via the outgoing COM port if using BT SPP.   BT SPP Connected BT SPP Disconnected
    89 Update  In this chapter, a brief on the symbology settings is provided for your reference.    IN THIS CHAPTER 4.1 Codabar ................................................................... 90 4.2 Code 25 - Industrial 25............................................... 92 4.3 Code 25 - Interleaved 25 ............................................ 95 4.4 Code 25 - Matrix 25 ................................................... 98 4.5 Code 39 ..................................................................101 4.6 Code 93 ..................................................................103 4.7 Code 128.................................................................103 4.8 EAN-8 .....................................................................104 4.9 EAN-13 ...................................................................106 44.10 GS1-128 (EAN-128) ................................................108 4.11 ISBT 128 ...............................................................109 4.12 MSI.......................................................................110 4.13 French Pharmacode.................................................113 4.14 Italian Pharmacode .................................................114 4.15 Plessey..................................................................115 44.16 GS1 DataBar (RSS Family) .......................................116 4.17 Telepen .................................................................120 4.18 UPC-A ...................................................................121 4.19 UPC-E ...................................................................123            Chapter 4 CHANGING SYMBOLOGY SETTINGS
90 Enter Setup 1560 Series Barcode Scanner User Guide  4.1 CODABAR   4.1.1 START/STOP CHARACTERS SELECTION Select one of the four different start/stop character pairs –                   *Enable Codabar Disable Codabar* abcd/abcd abcd/tn*e ABCD/ABCD ABCD/TN*E
    91 Update  Chapter 4   Changing Symbology Settings  4.1.2 START/STOP TRANSMISSION Decide whether or not to include the start/stop characters in the data being transmitted.     4.1.3 CLSI CONVERSION When enabled, the CLSI editing strips the start/stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar barcode.    Note:  The 14-character barcode length does not include start/stop characters.        *Do Not TransmitTransmit Codabar Start/Stop Characters Apply CLSI Editing *Do Not Apply
92 Enter Setup 1560 Series Barcode Scanner User Guide  4.2 CODE 25 – INDUSTRIAL 25   4.2.1 START/STOP PATTERN SELECTION This decides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 2 of 5 barcode but with Interleaved 2 of 5 start/stop pattern. In order to read this barcode, the start/stop pattern selection parameter of Industrial 2 of 5 should set to "Interleaved 25".                   *Enable Industrial 25 Disable Industrial 25*Industrial 25 Start/Stop Pattern Matrix 25        Start/Stop Pattern Interleaved 25 Start/Stop Pattern
    93 Update  Chapter 4   Changing Symbology Settings  4.2.2 CHECKSUM VERIFICATION Decide whether to verify the checksum. If the checksum is incorrect, the barcode will not be accepted.     4.2.3 CHECKSUM TRANSMISSION Decide whether to include the checksum in the data being transmitted.            Verify Industrial 25 Checksum *Transmit Industrial 25 Checksum Do Not Transmit*Do Not Verify
94 Enter Setup 1560 Series Barcode Scanner User Guide  4.2.4 CODE LENGTH QUALIFICATION Because of the weak structure of the 2 of 5 symbologies, it is possible to make a "short scan" error. To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length.  If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified.  If “Fixed Length” is selected, up to 2 fixed lengths can be specified.  1) Read the label to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.    2) Read the label for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2.    3) Read the “Decimal Value” label on page 187 for the desired length.   4) Read the “Validate” label on the same page to complete this setting.   *Enable Max./Min. Length (0 ~ 127) … Enable Fixed Length(s) …Max. Length (*127) Or Fixed Length 1 Min. Length (*4) Or Fixed Length 2
    95 Update  Chapter 4   Changing Symbology Settings  4.3 CODE 25 – INTERLEAVED 25   4.3.1 START/STOP PATTERN SELECTION This decides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 2 of 5 barcode but with Interleaved 2 of 5 start/stop pattern. In order to read this barcode, the start/stop pattern selection parameter of Industrial 2 of 5 should set to "Interleaved 25".                  *Enable Interleaved 25 Disable Interleaved 25Industrial 25 Start/Stop Pattern Matrix 25        Start/Stop Pattern *Interleaved 25 Start/Stop Pattern
96 Enter Setup 1560 Series Barcode Scanner User Guide  4.3.2 CHECKSUM VERIFICATION Decide whether to verify the checksum. If the checksum is incorrect, the barcode will not be accepted.     4.3.3 CHECKSUM TRANSMISSION Decide whether to include the checksum in the data being transmitted.           Verify Interleaved 25 Checksum *Transmit Interleaved 25 Checksum Do Not Transmit *Do Not Verify
    97 Update  Chapter 4   Changing Symbology Settings  4.3.4 CODE LENGTH QUALIFICATION Because of the weak structure of the 2 of 5 symbologies, it is possible to make a "short scan" error. To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length.  If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified.  If “Fixed Length” is selected, up to 2 fixed lengths can be specified.  1) Read the label to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.    2) Read the label for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2.     3) Read the “Decimal Value” label on page 187 for the desired length.   4) Read the “Validate” label on the same page to complete this setting.      Enable Fixed Length(s) …*Enable Max./Min. Length (0 ~ 127) … Max. Length (*126) Or Fixed Length 1 Min. Length (*4) Or Fixed Length 2
98 Enter Setup 1560 Series Barcode Scanner User Guide  4.4 CODE 25 – MATRIX 25   4.4.1 START/STOP PATTERN SELECTION This decides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 2 of 5 barcode but with Interleaved 2 of 5 start/stop pattern. In order to read this barcode, the start/stop pattern selection parameter of Industrial 2 of 5 should set to "Interleaved 25".                   Enable Matrix 25 *Disable Matrix 25Industrial 25 Start/Stop Pattern *Matrix 25        Start/Stop Pattern Interleaved 25 Start/Stop Pattern
    99 Update  Chapter 4   Changing Symbology Settings  4.4.2 CHECKSUM VERIFICATION Decide whether to verify the checksum. If the checksum is incorrect, the barcode will not be accepted.     4.4.3 CHECKSUM TRANSMISSION Decide whether to include the checksum in the data being transmitted.           Verify Matrix 25 Checksum *Transmit Matrix 25 Checksum Do Not Transmit*Do Not Verify
100 Enter Setup 1560 Series Barcode Scanner User Guide  4.4.4 CODE LENGTH QUALIFICATION Because of the weak structure of the 2 of 5 symbologies, it is possible to make a "short scan" error. To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length.  If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified.  If “Fixed Length” is selected, up to 2 fixed lengths can be specified.  1) Read the label to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.    2) Read the label for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2.    3) Read the “Decimal Value” label on page 187 for the desired length.   4) Read the “Validate” label on the same page to complete this setting.    Enable Fixed Length(s) …*Enable Max./Min. Length (0 ~ 127) … Min. Length (*4) Or Fixed Length 2 Max. Length (*127) Or Fixed Length 1
    101 Update  Chapter 4   Changing Symbology Settings  4.5 CODE 39   4.5.1 START/STOP TRANSMISSION Decide whether or not to include the start/stop characters in the data being transmitted.     4.5.2 CHECKSUM VERIFICATION Decide whether or not to perform checksum verification when decoding barcodes.    If enabled and the checksum found incorrect, the barcode will not be accepted.       *Enable Code 39 Disable Code 39Transmit Code 39 Start/Stop Characters *Do Not TransmitVerify Code 39 Checksum *Do Not Verify
102 Enter Setup 1560 Series Barcode Scanner User Guide  4.5.3 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted.     4.5.4 STANDARD/FULL ASCII CODE 39 Decide whether or not to support Code 39 Full ASCII that includes all the alphanumeric and special characters.                     Code 39 Full ASCII *Standard Code 39*Transmit Code 39 Checksum Do Not Transmit
    103 Update  Chapter 4   Changing Symbology Settings  4.6 CODE 93 You can only configure the scanner to read this symbology or not.    4.7 CODE 128 You can only configure the scanner to read this symbology or not.                   *Enable Code 93 Disable Code 93*Enable Code 128 Disable Code 128
104 Enter Setup 1560 Series Barcode Scanner User Guide  4.8 EAN-8               *Enable EAN-8 (No Addon) Disable EAN-8 (No Addon) *Disable EAN-8 Addon 2 *Disable EAN-8 Addon 5 Enable EAN-8 Addon 2 Enable EAN-8 Addon 5
    105 Update  Chapter 4   Changing Symbology Settings  4.8.1 CONVERT TO EAN-13 Decide whether or not to expand the read EAN-8 barcode into EAN-13.    If enabled, the next processing will follow the parameters configured for EAN-13.     4.8.2 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted.        Convert EAN-8 to EAN-13 *Transmit EAN-8 Checksum Do Not Transmit*Do Not Convert
106 Enter Setup 1560 Series Barcode Scanner User Guide  4.9 EAN-13              Disable EAN-13 (No Addon) *Disable EAN-13 Addon 2 *Disable EAN-13 Addon 5 Enable EAN-13 Addon 2 Enable EAN-13 Addon 5 *Enable EAN-13 (No Addon)
    107 Update  Chapter 4   Changing Symbology Settings  4.9.1 ISBN CONVERSION Decide whether or not to convert the EAN-13 barcode, starting with 978 and 979, to ISBN.    4.9.2 ISSN CONVERSION Decide whether or not to convert the EAN-13 barcode, starting with 977 to ISSN.    4.9.3 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted.       Convert EAN-13 to ISBN *Do Not Convert*Do Not ConvertConvert EAN-13 to ISSN Do Not Transmit*Transmit EAN-13 Checksum
108 Enter Setup 1560 Series Barcode Scanner User Guide  4.10 GS1-128 (EAN-128)   4.10.1 CODE ID TRANSMISSION Decide whether or not to include the Code ID ("]C1") in the data being transmitted.     4.10.2 FIELD SEPARATOR (GS CHARACTER) Decide whether or not to apply a field separator (to convert the FNC1 control character to human readable character).    1) Read the label above to enable field separator. 2) Read the “Hexadecimal Value” label on page 188 for the desired character string.   3) Read the “Validate” label to complete this setting. Enable EAN-128*Disable EAN-128Transmit EAN-128 Code ID *Do Not TransmitEnable Field Separator …
    109 Update  Chapter 4   Changing Symbology Settings  Note: EAN-128 barcodes start with the FNC1 control character to distinguish themselves from other uses of Code 128. FNC1 is also used to separate data fields in the EAN-128 barcodes. 4.11 ISBT 128 You can only configure the scanner to read this symbology or not.       Enable ISBT 128 *Disable ISBT 128
110 Enter Setup 1560 Series Barcode Scanner User Guide  4.12 MSI   4.12.1 CHECKSUM VERIFICATION Select one of the three checksum calculations to perform checksum verification when decoding barcodes.  If enabled and the checksum found incorrect, the barcode will not be accepted.                   Enable MSI *Disable MSI*Single Modulo 10 Double Modulo 10Modulo 10 & 11
    111 Update  Chapter 4   Changing Symbology Settings  4.12.2 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted.                                   *Last Digit Not Transmitted Both Digits Not Transmitted Both Digits Transmitted
112 Enter Setup 1560 Series Barcode Scanner User Guide  4.12.3 CODE LENGTH QUALIFICATION Because of the weak structure of the symbology, it is possible to make a "short scan" error. To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length.    If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified.  If “Fixed Length” is selected, up to 2 fixed lengths can be specified. Note:   The specified barcode length(s) must include the checksum, regardless of which option is selected for “Checksum Transmission”. 1) Read the label to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.    2) Read the label for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2.       3) Read the “Decimal Value” label on page 187 for the desired length.   4) Read the “Validate” label on the same page to complete this setting. Enable Fixed Length(s) …*Enable Max./Min. Length (0 ~ 127) … Min. Length (*4) Or Fixed Length 2 Max. Length (*127) Or Fixed Length 1
    113 Update  Chapter 4   Changing Symbology Settings  4.13 FRENCH PHARMACODE   4.13.1 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted.                        Enable French Pharmacode *Disable French Pharmacode *Transmit French Pharmacode Checksum Do Not Transmit
114 Enter Setup 1560 Series Barcode Scanner User Guide  4.14 ITALIAN PHARMACODE    4.14.1 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted.         Enable Italian Pharmacode *Disable Italian Pharmacode *Transmit Italian Pharmacode Checksum Do Not Transmit
    115 Update  Chapter 4   Changing Symbology Settings  4.15 PLESSEY   4.15.1 CONVERT TO UK PLESSEY Decide whether or not to change each occurrence of the character 'A' to character 'X' in the decoded data.    4.15.2 CHECKSUM TRANSMISSION Decide whether or not to include the checksum characters (two digits) in the data being transmitted.     Enable Plessey*Disable PlesseyConvert to UK Plessey *Do Not Convert*Transmit Plessey Checksum Do Not Transmit
116 Enter Setup 1560 Series Barcode Scanner User Guide  4.16 GS1 DATABAR (RSS FAMILY) 4.16.1 CODE ID SELECTION Select a desired Code ID to use – RSS Code ID "]e0” or EAN-128 Code ID "]C1".    4.16.2 GS1 DATABAR OMNIDIRECTIONAL (RSS-14)    Code ID Transmission Decide whether or not to include the Code ID in the data being transmitted.    Enable RSS-14 & RSS Expanded *Disable RSS-14 & RSS Expanded “]C1” for RSS Code ID “]e0” for RSS Code ID (Default) *Transmit RSS-14 Code ID Do Not Transmit
    117 Update  Chapter 4   Changing Symbology Settings  Application ID Transmission Decide whether or not to include the Application ID ("01") in the data being transmitted.    Checksum Transmission Decide whether or not to include the check digit in the data being transmitted.    4.16.3 GS1 DATABAR EXPANDED (RSS EXPANDED)     Enable RSS-14 & RSS Expanded *Disable RSS-14 & RSS Expanded *Transmit RSS-14 Application ID Do Not Transmit*Transmit RSS-14 Checksum Do Not Transmit
118 Enter Setup 1560 Series Barcode Scanner User Guide  Code ID Transmission Decide whether or not to include the Code ID in the data being transmitted.    4.16.4 GS1 DATABAR LIMITED (RSS LIMITED)   Code ID Transmission Decide whether or not to include the Code ID in the data being transmitted.       Enable RSS Limited *Disable RSS Limited*Transmit RSS Expanded Code ID Do Not Transmit*Transmit RSS Limited Code ID Do Not Transmit
    119 Update  Chapter 4   Changing Symbology Settings  Application ID Transmission Decide whether or not to include the Application ID ("01") in the data being transmitted.      Checksum Transmission Decide whether or not to include the check digit in the data being transmitted.                *Transmit RSS Limited Application ID Do Not Transmit*Transmit RSS Limited Checksum Do Not Transmit
120 Enter Setup 1560 Series Barcode Scanner User Guide  4.17 TELEPEN   4.17.1 TELEPEN OUTPUT – FULL ASCII/NUMERIC Decide whether or not to support Telepen in full ASCII code. By default, it supports ASCII mode.  AIM Telepen (Full ASCII) includes all the alphanumeric and special characters.          Enable Telepen*Disable TelepenOriginal Telepen     (Numeric) *AIM Telepen
    121 Update  Chapter 4   Changing Symbology Settings  4.18 UPC-A              Disable UPC-A (No Addon) *Disable UPC-A Addon 2 *Disable UPC-A Addon 5 Enable UPC-A Addon 2 Enable UPC-A Addon 5 *Enable UPC-A (No Addon)
122 Enter Setup 1560 Series Barcode Scanner User Guide  4.18.1 CONVERT TO EAN-13 Decide whether or not to expand the read UPC-A barcode into EAN-13.   If enabled, the next processing will follow the parameters configured for EAN-13.     4.18.2 SYSTEM NUMBER TRANSMISSION Decide whether or not to include the system number in the data being transmitted.     4.18.3 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted.     Convert UPC-A to EAN-13 *Do Not ConvertDo Not Transmit*Transmit UPC-A Checksum Do Not Transmit*Transmit UPC-A System Number
    123 Update  Chapter 4   Changing Symbology Settings  4.19 UPC-E               Disable UPC-E (No Addon) *Disable UPC-E Addon 2 *Disable UPC-E Addon 5 Enable UPC-E Addon 2 Enable UPC-E Addon 5 *Enable UPC-E (No Addon)
124 Enter Setup 1560 Series Barcode Scanner User Guide  4.19.1 SYSTEM NUMBER SELECTION Decide whether to decode the ordinary UPC-E barcodes only or both UPC-E0 and UPC-E1 barcodes.  System number 0 enabled for decoding UPC-E0 barcodes.  System number 1 enabled for decoding UPC-E1 barcodes.     Warning:  Because of the way system number 1 is encoded, if both system numbers are enabled, the user might suffer from short scanning UPC-A or EAN-13 barcodes into UPC-E1 barcodes. 4.19.2 CONVERT TO UPC-A Decide whether or not to expand the read UPC-E barcode into UPC-A.    If enable, the next processing will follow the parameters configured for UPC-A.             Convert UPC-E to UPC-A *Do Not ConvertSystem Number 0 & 1 * System Number 0 Only
    125 Update  Chapter 4   Changing Symbology Settings  4.19.3 SYSTEM NUMBER TRANSMISSION Decide whether or not to include the system number in the data being transmitted.     4.19.4 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted.       Do Not Transmit*Transmit UPC-E Checksum *Do Not TransmitTransmit UPC-E System Number
126 Enter Setup 1560 Series Barcode Scanner User Guide
    127 Update  You may configure in which format the collected data will be output to the host computer. Barcode read by the scanner will be processed in the following sequence –   1) Perform character substitution on the data scanned. 2) Add Code ID and Length Code to the front of the data:[Code ID][Length Code][Data] 3) Process the whole data in step 2 with user formats. Data is now divided into fields by user specified rules. Refer to Chapter 6 Applying Formats for Data Editing. 4) Add  Prefix Code and Suffix Code before transmission:[Prefix Code][Processed Data][Suffix Code] IN THIS CHAPTER 5.1 Letter Case ..............................................................127 5.2 Character Substitution...............................................128 5.3 Prefix/Suffix Code .....................................................134 5.4 Code ID...................................................................135 5.5 Length Code ............................................................139 5.6 Multi-Barcode Editor..................................................142 5.7 Removal of Special Character .....................................145 5.1 LETTER CASE By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case. Ignoring the original letter case, select [Upper Case] to output data in upper case only; otherwise, select [Lower Case] to output data in lower case only.      Chapter 5 DEFINING OUTPUT FORMAT *Normal Upper CaseLower Case
128 Enter Setup 1560 Series Barcode Scanner User Guide  5.2 CHARACTER SUBSTITUTION Character substitution is performed on every occurrence of the first character specified. If only one character is specified, every occurrence of that character in the barcode will be taken away.  The first character will be replaced by the second character(s).    Up to three sets of character substitution can be configured. Note: The character substitution is performed only on the barcode itself and before the processing of editing formats. It is not applicable to the Prefix/Suffix Code, Code ID, Length Code, or any Additional Field. 5.2.1 SELECT A SET FOR CHARACTER SUBSTITUION    1) Read the label above to enable character substitution by set.   For example, have the scanner read the “Set 1” label to configure the first set of character substitution. The scanner will respond with one short beep, high tone, to indicate more setup labels are required. 2) Read the “Hexadecimal Value” label on page 188 for the desired character string. For example, have the scanner read (1) “3”, “0”, “2” and “D” to replace the character [0] with a dash [-] for Set 1, and (2) “3”, “0”, “2”, “D”, “3” and “0”to replace the character [0] with a dash [- 0] for Set 2. 3) Read the “Validate” label to complete this setting. (The defined set or sets will be applied to all symbologies by default.) Configure Set 1 Configure Set 2Configure Set 3
    129 Update  Chapter 5   Defining Output Format  5.2.2 SYMBOLOGIES FOR CHARACTER SUBSTITUTION (ALL 3 SETS) By default character substitution will be performed on all symbologies. If the character substitution is not desired with one or more symbologies, read the “Do Not Apply” label for each undesired symbologies and all the three sets will be ignored for them. Character Substitution for Codabar                                       Character Substitution for Code 39                                       Character Substitution for Code 93                                       Character Substitution for Code 128                                       Character Substitution for GS1-128 (EAN-128)                                           *Apply Do Not Apply*Apply Do Not Apply*Apply Do Not Apply*Apply Do Not Apply*Apply Do Not Apply
130 Enter Setup 1560 Series Barcode Scanner User Guide  Character Substitution for EAN-8 (No Addon)                                       Character Substitution for EAN-8 Addon 2                                       Character Substitution for EAN-8 Addon 5                                       Character Substitution for EAN-13 (No Addon)                                       Character Substitution for EAN-13 Addon 2                                       Character Substitution for EAN-13 Addon 5                                          *Apply Do Not ApplyDo Not Apply*Apply *Apply Do Not Apply*Apply Do Not Apply*Apply Do Not ApplyDo Not Apply*Apply
    131 Update  Chapter 5   Defining Output Format  Character Substitution for French Pharmacode                                       Character Substitution for Italian Pharmacode                                       Character Substitution for Industrial 25                                       Character Substitution for Interleaved 25                                       Character Substitution for Matrix 25                                       Character Substitution for MSI                                         *Apply Do Not Apply*Apply Do Not Apply*Apply Do Not Apply*Apply Do Not Apply*Apply Do Not Apply*Apply Do Not Apply
132 Enter Setup 1560 Series Barcode Scanner User Guide  Character Substitution for Plessey                                       Character Substitution for GS1 DataBar (RSS)                                       Character Substitution for Telepen                                       Character Substitution for UPC-A (No Addon)                                       Character Substitution for UPC-A Addon 2                                       Character Substitution for UPC-A Addon 5                                          *Apply Do Not Apply*Apply Do Not Apply*Apply Do Not Apply*Apply Do Not Apply*Apply Do Not Apply*Apply Do Not Apply
    133 Update  Chapter 5   Defining Output Format  Character Substitution for UPC-E (No Addon)                                       Character Substitution for UPC-E Addon 2                                       Character Substitution for UPC-E Addon 5                                                     *Apply Do Not Apply*Apply Do Not Apply*Apply Do Not Apply
134 Enter Setup 1560 Series Barcode Scanner User Guide  5.3 PREFIX/SUFFIX CODE By default, there is no prefix code, and [ENTER] or [CR] (Carriage Return) is configured to be suffix code. Up to 8 characters can be configured, for example, “Barcode_”, and you will have the string appear in front of the barcode read, like this – “Barcode_1234567890”.  If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. Refer to Keyboard Wedge Table. Key Type  Key Status Scan Code    Up to 4 scan code values are allowed.  N/A Normal Key    Up to 8 character strings are allowed.  Default setting  Add Shift  Add Left Ctrl  Add Left Alt  Add Right Ctrl  Add Right Alt  Add Break For example, read labels for [Add Shift], [A], [Add Shift], and [B].      1) Read the label above to apply prefix code or suffix code separately, and follow steps 2~3. (Max. 8 characters each) 2) Read the “Hexadecimal Value” label on page 188 for the desired character string. For example, read “2” and “B” for the scanner to prefix or suffix the character [+]. 3) Read the “Validate” label to complete this setting. Configure Prefix Configure Suffix
    135 Update  Chapter 5   Defining Output Format  5.4 CODE ID Up to two characters for Code ID can be configured for each symbology. To make the Code ID configuration easier, the scanner provides five pre-defined Code ID sets that you can select one and make necessary changes on it.  If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. Refer to Keyboard Wedge Table. Key Type  Key Status Scan Code    Up to 1 scan code values are allowed.  N/A Normal Key    Up to 2 character strings are allowed.  Default setting  Add Shift  Add Left Ctrl  Add Left Alt  Add Right Ctrl  Add Right Alt  Add Break For example, read labels for [Add Shift] and the character [A]. Note:  "]C1" is the Code ID of GS1-128 (EAN-128) barcodes; "]e0" is the default Code ID of GS1 DataBar (RSS) barcodes. 5.4.1 SELECT PRE-DEFINED CODE ID Code ID options  Set 1  Set 2  Set 3  Set 4  Set 5 Code 39  A  C  Y  M  A Italian Pharmacode  A  C  Y  M  A French Pharmacode  A  C  Y  M  A Industrial 25 C H H H S Interleaved 25  D  I  Z  I  S Matrix 25 E  G G G S Codabar F  N  X  N  F Code 93 I  L L L G Code 128 H K K K C UPC-E S E C E E EAN-8 P B B FF E EAN-13 M A A F  E
136 Enter Setup 1560 Series Barcode Scanner User Guide  UPC-A  J  A A A E MSI V V D P M Plessey W W E Q P Telepen  Z  --- --- --- ---          5.4.2 CHANGE CODE ID 1) Read the label of a specific symbology below to change its code ID. 2) Read the “Hexadecimal Value” label on page 188 for the desired character string. For example, read “4” and “4” for applying the character [D] for Code ID. 3) Read the “Validate” label to complete this setting. Apply Code ID Set 1 Apply Code ID Set 2Apply Code ID Set 3 Apply Code ID Set 4Apply Code ID Set 5
    137 Update  Chapter 5   Defining Output Format              Configure Code ID for CodabarConfigure Code ID for Code 39Configure Code ID for Code 93Configure Code ID for Code 128Configure Code ID for EAN-8 Configure Code ID for EAN-13Configure Code ID for French Pharmacode Configure Code ID for Italian PharmacodeConfigure Code ID for Industrial 25 Configure Code ID for Interleaved 25
138 Enter Setup 1560 Series Barcode Scanner User Guide         5.4.3 CLEAR CODE ID SETTINGS               Configure Code ID for Matrix 25Configure Code ID for MSI Configure Code ID for Plessey Configure Code ID for TelepenConfigure Code ID for UPC-A Configure Code ID for UPC-EClear All Code ID Settings
    139 Update  Chapter 5   Defining Output Format  5.5 LENGTH CODE A two-digit code representing the length of barcode data (character count) can be inserted in front of data being transmitted. Such "Length" code can be individually enabled or disabled for each symbology. Length Code for Codabar                               Length Code for Code 39                               Length Code for Code 93                               Length Code for Code 128                               Length Code for GS1-128 (EAN-128) & GS1 DataBar (RSS)                               Length Code for EAN-8                                  Apply *Do Not Apply *Do Not Apply Apply Apply Apply Apply *Do Not Apply *Do Not Apply *Do Not Apply *Do Not Apply Apply
140 Enter Setup 1560 Series Barcode Scanner User Guide  Length Code for EAN-13                               Length Code for French Pharmacode                               Length Code for Italian Pharmacode                               Length Code for Industrial 25                               Length Code for Interleaved 25                               Length Code for Matrix 25                               Length Code for MSI                                 *Do Not Apply *Do Not Apply *Do Not Apply *Do Not Apply *Do Not Apply *Do Not Apply *Do Not Apply Apply Apply Apply Apply Apply Apply Apply
    141 Update  Chapter 5   Defining Output Format  Length Code for Plessey                               Length Code for Telepen                               Length Code for UPC-A                               Length Code for UPC-E                                                   Apply Apply Apply Apply *Do Not Apply *Do Not Apply *Do Not Apply *Do Not Apply
142 Enter Setup 1560 Series Barcode Scanner User Guide  5.6 MULTI-BARCODE EDITOR The Multi-Barcode Editor allows you to decide the output sequence of a concatenation of barcodes. Up to five barcodes can be specified. When you enable this mode, it will force the scanner to apply Laser mode as the scan mode.   Note:  The Multi-Barcode Editor has nothing to do with Multi-Barcode Mode. The barcodes that are found meeting the specified criteria below will be arranged in the desired sequence.   Code Type  4-digit barcode length, excluding prefix, suffix, length code, etc.  Matching the first character of barcode data
    143 Update  Chapter 5   Defining Output Format  5.6.1 EDIT A CONCATENATION OF BARCODES   1) Read the label above to start editing a concatenation of barcodes. 2) Code Type setting – read the “Hexadecimal Value” label on page 188 for Code Type of the (first) barcode. For example, read “4” and “1” for Code 39. Code Type  Symbology  Code Type  Symbology 41 (A)  Code 39  4F (O)  EAN-8 with Addon 5 42 (B)  Italian Pharmacode  50 (P)  EAN-13 43 (C)  French Pharmacode)  51 (Q)  EAN-13 with Addon 2 44 (D)  Industrial 25  52 (R)  EAN-13 with Addon 5 45 (E)  Interleaved 25  53 (S)  MSI 46 (F)  Matrix 25  54 (T)  Plessey 47 (G)  Codabar (NW7)  55 (U)  GS1-128 (EAN-128) 48 (H)  Code 93  56 (V)  UPC-A 49 (I)  Code 128  57 (W)  UPC-A with Addon 2 4A (J)  UPC-E0 / UPC-E1  58 (X)  UPC-A with Addon 5 4B (K)  UPC-E with Addon 2     4C (L)  UPC-E with Addon 5  5A (Z)  Telepen 4D (M)  EAN-8  5B ( [ )  GS1 DataBar (RSS) 4E (N)  EAN-8 with Addon 2      3) Barcode Length setting – read the “Decimal Value” label on page 187 for the 4-digit length of the (first) barcode. For example, read “0065” for barcode length of 65 characters or read “0000” for any length.   Note: If not reading 0000 for any length, the 4-digit length must exclude prefix, suffix (0x0d by default), length code, etc. 4) Matching Character setting – read the “Hexadecimal Value” label on page 188 for the 1st character that must be found matching in the (first) barcode. For example, read “4” and “1” for matching character “A” as the first character in the barcode or read “00” for any character. 5) Read twice the “F” label on page 188 (“FF”) to complete the setting of each barcode. 6) Read the “Validate” label to end the editing of the barcode set. Edit Output Sequence
144 Enter Setup 1560 Series Barcode Scanner User Guide  5.6.2 ACTIVATE THE CONCATENATION OF BARCODES By default, the output sequence editing of the concatenation of barcodes is not applied.   When “Enforce Output Sequence” is enabled, all barcodes read by the scanner must meet with the criteria for the concatenation. If data is found excluded from all output sequence sets (= not meeting with the criteria), the scanner will not accept the reading, and therefore, data will not be transmitted. When “Apply Output Sequence” is enabled, only barcodes found meeting with the criteria are counted for the concatenation. Those found not meeting with the criteria are processed normally and individually. Note: When it requires reading more barcodes to complete the “output sequence” requirements, the scanner will respond with one short beep (low tone). After reading an acceptable barcode, its LED indicator will become solid green and go off quickly (= Good Read).         Upon completion of reading acceptable barcodes, the scanner will respond with one short beep (high tone) and its LED indicator will become solid green and go off quickly (= Good Read).        Warning:  When you disable the Multi-Barcode Editor later, the scan mode remains unchanged. If Laser mode is not desired, proceed to select a scan mode best suits your application.       *Ignore Output Sequence Enforce Output Sequence Apply Output Sequence
    145 Update  Chapter 5   Defining Output Format  5.7 REMOVAL OF SPECIAL CHARACTER You can only specify 1 character, but it will remove every matching character encountered from the starting position of barcode data until a different character is met. For example, if it is configured to remove the character “0” (hex value is “30”), one or more zeros will be stripped off the barcode data “012345” and “00012345”. However, for barcode data “010333”, only the first zero will be stripped off. 1) Read the label below to remove the specified character.    2) Read the “Hexadecimal Value” label on page 188 for the desired character.   For example, read “3” and “0” for the scanner to remove the character “0”. 3) Read the “Validate” label to complete this setting.   Remove Special Character
146 Enter Setup 1560 Series Barcode Scanner User Guide
    147 Update  The scanner allows advanced data editing by applying user-configured editing formats. The whole processed data can be divided into fields by user-specified rules. These fields together with the user-configurable additional fields consist of the data actually sent to the host computer.    [Prefix Code] [Code ID]  [Length Code] [Data] [Suffix Code] Additional Field(s) None        by default None        by default None        by default Barcode itself  0x0d        by default   IN THIS CHAPTER 6.1 Format Selection ......................................................148 6.2 Editing Format..........................................................150 6.3 Programming Examples .............................................166                            Chapter 6 APPLYING FORMATS FOR DATA EDITING
148  End Programming Format 1560 Series Barcode Scanner User Guide  6.1 FORMAT SELECTION 6.1.1 ACTIVATE EDITING FORMATS If you have already configured any editing format before, you may directly apply the editing format. If not, you must start with configuring an editing format first, and then, activate the editing format when it is desired in use. Editing Format 1                              Editing Format 2                               Editing Format 3                                   *Disable Format 1 Enable Format 1 *Disable Format 2Enable Format 2 *Disable Format 3Enable Format 3
    149 Update  Chapter 6   Applying Formats for Data Editing  Editing Format 4                             Editing Format 5  6.1.2 EXCLUSIVE DATA EDITING By default, only barcodes found meeting with the criteria are processed by the editing formats. Those found not meeting with the criteria are processed normally. When “Exclusive Data Editing” is enabled, all barcodes read by the scanner must be processed by the editing formats. If data is found excluded from all enabled editing formats (= not meeting with the specified criteria), the scanner will not accept the reading, and therefore, data will not be transmitted.        Yes  *No *Disable Format 4Enable Format 4 *Disable Format 5Enable Format 5
150  End Programming Format 1560 Series Barcode Scanner User Guide  6.2 EDITING FORMAT
    151 Update  Chapter 6   Applying Formats for Data Editing  6.2.1 SELECT FORMAT TO CONFIGURE Start Programming Format Select one editing format (Format 1~5) and the parameters pertaining to the editing format can then be configured – applicable code type, data length, matching string & location, total number of fields, field settings (field-dividing rule), additional fields, and field transmission sequence.  Up to five different formats can be specified.     Note: Before you complete the programming of an editing format, if you have the scanner read any label for parameters other than those pertaining to the editing format, it will automatically abort the programming process.   End Programming Format After having configured all the desired parameters, you must have the scanner read the “End Programming Format” label, which can be located at the bottom of every even page in this chapter.  End Programming FormatConfigure Format 1 Configure Format 3 Configure Format 4Configure Format 5 Configure Format 2
152  End Programming Format 1560 Series Barcode Scanner User Guide  6.2.2 RESTORE DEFAULT FORMAT You may select an existing editing format and have the defaults restored. The default settings of an editing format are listed below. Editing format  Defaults Applicable Code Type  All Data Length  0 (No qualification.) Matching String  Disable Matching String Location  None Total Number of Fields  1 Field Setting – field-dividing rule  Not configured. Additional Fields  None Field Transmission Sequence  F1                            Restore Default Format
    153 Update  Chapter 6   Applying Formats for Data Editing  6.2.3 DEFINE DATA CRITERIA Three applicable conditions can be configured to check whether the data read by the scanner can be processed by the particular editing format.   Note:  Data editing cannot be performed unless the three conditions are all met. Applicable Code Type By default, barcodes of all the supported symbologies will be processed by any editing format, if having been configured and enabled.                                                                                                                                                                                                                                     *Apply to AllCodabar Code 39 Code 93  Code 128 EAN-8 EAN-8 Addon 2EAN-8 Addon 5  EAN-13 EAN-13 Addon 2 EAN-13 Addon 5Clear All
154  End Programming Format 1560 Series Barcode Scanner User Guide                                                                                                                                                                                                                                                                             Data Length The length must include prefix, suffix (0x0d by default), length code, etc. By default, barcodes of any length (character count) are eligible for data editing.  Italian Pharmacode Industrial 25Interleaved 25  Matrix 25 MSI Plessey UPC-A Addon 2 UPC-A Addon 5UPC-E UPC-E Addon 2Telepen  UPC-A  EAN-128 & RSS French PharmacodeUPC-E Addon 5
    155 Update  Chapter 6   Applying Formats for Data Editing   You may specify a value from 0 to 254.  When zero is given to both, the scanner will not perform the length qualification.  1. Read the label below to specify Max. Length or Min. Length separately, and follow steps 2~3.   2. Read the “Decimal Value” label on page 187 for the desired length.   3. Read the “Validate” label on the same page to complete this setting. Matching String & Location By default, no matching string is specified, and therefore, it is disabled. You may enable this feature by specifying a matching string; up to four characters are allowed.   When the Matching String Location is zero, the scanner will only check for the existence of the matching string in the barcode data.   You may specify a value from 1 to 254 to indicate where the matching string starts in the barcode data.  1. Read the label to specify a matching string.    2. Read the “Hexadecimal Value” label on page 188 for the desired character string.   3. Read the “Validate” label to complete this setting. 4. Read the label to specify the location of the matching string.   5. Read the “Decimal Value” label on page 187 for the desired location. 6. Read the “Validate” label on the same page to complete this setting. Max. Length Min. LengthMatching String …Location of Matching String …
156  End Programming Format 1560 Series Barcode Scanner User Guide  6.2.4 DIVIDE DATA INTO FIELDS Start Position Data can be divided into fields in one of the following direction –    from head (F1) to tail (F5)  from tail (F1) to head (F5)   Field Adjustment You may apply equal length to all fields, if necessary. It will add “Space” (0x20) to field when data is found shorter than specified.    1. Read the label above to adjust field by length.   2. Read the “Decimal Value” label on page 187 for the desired field length. 3. Read the “Validate” label on the same page to complete this setting. Total Number of Fields Data can be divided into at most 6 fields; each of them is numbered from F1 to F6 accordingly. However, only F1~F5 can be configured.    The total number of fields must be specified correctly. If three fields are configured for the editing format, the data characters after F3 will be assigned to F4 automatically. This feature is quite useful especially when data of variable lengths is processed by editing formats.   *From Head From Tail Set Length to adjust fields … (*0)*No Adjustment *One Field
    157 Update  Chapter 6   Applying Formats for Data Editing       Note: The number of configurable fields is always one less than the total number of fields specified. The extra data characters beyond the last field configured will be automatically assigned to the next field.            Two Fields Three FieldsFour FieldsFive Fields Six Fields
158  End Programming Format 1560 Series Barcode Scanner User Guide  6.2.5 FIELD SETTINGS Data eligible for editing formats is divided into fields by user-specified rules – either using the field terminating string or specified field length. By Terminating String Specify the field terminating string. Up to two characters are allowed. The scanner will search for the occurrence of this particular string in the data.    By default, this string will be included in the field. You may discard it. By Length Alternatively, you may simply specify the field length. The scanner will assign the next specified number of characters into the field.    Field 1 Setting    1. Read the above label to divide field by a specified terminating string. 2. Read the “Hexadecimal Value” label on page 188 for the desired character string.   3. Read the “Validate” label to complete this setting. 4. Read the “Discard Separator” label if the field separator is not desired in the field.                                 If not dividing the field by a specific separator, you may divide it by a specified length.    1. Read the above label to divide field by length. 2. Read the “Decimal Value” label on page 187 for the desired field length. 3. Read the “Validate” label on the same page to complete this setting. Select Field Separator to Divide Field 1 … *Include Separator Discard Separator Divide Field 1 by Length …
    159 Update  Chapter 6   Applying Formats for Data Editing  Field 2 Setting    1. Read the above label to divide field by a specified terminating string. 2. Read the “Hexadecimal Value” label on page 188 for the desired character string.   3. Read the “Validate” label to complete this setting. 4. Read the “Discard Separator” label if the field separator is not desired in the field.                                 If not dividing the field by a specific separator, you may divide it by a specified length.    1. Read the above label to divide field by length. 2. Read the “Decimal Value” label on page 187 for the desired field length. 3. Read the “Validate” label on the same page to complete this setting.                  Select Field Separator to Divide Field 2 … *Include Separator Discard Separator Divide Field 2 by Length …
160  End Programming Format 1560 Series Barcode Scanner User Guide  Field 3 Setting    1. Read the above label to divide field by a specified terminating string. 2. Read the “Hexadecimal Value” label on page 188 for the desired character string.   3. Read the “Validate” label to complete this setting. 4. Read the “Discard Separator” label if the field separator is not desired in the field.                                 If not dividing the field by a specific separator, you may divide it by a specified length.    1. Read the above label to divide field by length. 2. Read the “Decimal Value” label on page 187 for the desired field length. 3. Read the “Validate” label on the same page to complete this setting.                   Select Field Separator to Divide Field 3 … *Include Separator Discard Separator Divide Field 3 by Length …
    161 Update  Chapter 6   Applying Formats for Data Editing  Field 4 Setting    1. Read the above label to divide field by a specified terminating string. 2. Read the “Hexadecimal Value” label on page 188 for the desired character string.   3. Read the “Validate” label to complete this setting. 4. Read the “Discard Separator” label if the field separator is not desired in the field.                                 If not dividing the field by a specific separator, you may divide it by a specified length.    1. Read the above label to divide field by length. 2. Read the “Decimal Value” label on page 187 for the desired field length. 3. Read the “Validate” label on the same page to complete this setting.                   Select Field Separator to Divide Field 4 … *Include Separator Discard Separator Divide Field 4 by Length …
162  End Programming Format 1560 Series Barcode Scanner User Guide  Field 5 Setting    1. Read the above label to divide field by a specified terminating string. 2. Read the “Hexadecimal Value” label on page 188 for the desired character string.   3. Read the “Validate” label to complete this setting. 4. Read the “Discard Separator” label if the field separator is not desired in the field.                                 If not dividing the field by a specific separator, you may divide it by a specified length.    1. Read the above label to divide field by length. 2. Read the “Decimal Value” label on page 187 for the desired field length. 3. Read the “Validate” label on the same page to complete this setting.                   Select Field Separator to Divide Field 5 … *Include Separator Discard Separator Divide Field 5 by Length …
    163 Update  Chapter 6   Applying Formats for Data Editing  Additional Fields Up to five additional fields can be created for each editing format; each of them is numbered from AF1 to AF5 accordingly.   1. Read the label below to specify an additional field, one at a time. 2. Read the “Hexadecimal Value” label on page 188 for the desired additional field.   3. Read the “Validate” label to complete this setting.                                                                          If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. Refer to Keyboard Wedge Table. Key Type  Key Status Scan Code    Up to 2 scan code values are allowed. N/A Normal Key  Up to 4 character strings are allowed.  Default setting  Add Shift  Add Left Ctrl  Add Left Alt  Add Right Ctrl  Add Right Alt  Add Break For example, read labels for [Add Shift], [A], [Add Shift], and [B].       Additional Field 1 … Additional Field 2 …Additional Field 4 …Additional Field 5 … Additional Field 3 …
164  End Programming Format 1560 Series Barcode Scanner User Guide  6.2.6 FIELD TRANSMISSION SEQUENCE After configuring the data fields and additional fields, you must now program the transmission sequence of these fields that comprise the final data. This field transmission sequence can be assigned in any desired order and fields can be assigned multiple times as well.   Note:  Up to twelve fields can be assigned. 1) Read the “Start” label to begin with programming the field transmission sequence.  2) Program the transmission sequence by reading the desired fields as well as additional fields.                                                                                                                                                                                                                       Start (Programming) …Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Additional Field 1 Additional Field 2Additional Field 3 Additional Field 4Additional Field 5
    165 Update  Chapter 6   Applying Formats for Data Editing  3) Read the “End” label to complete this setting.  End
166  End Programming Format 1560 Series Barcode Scanner User Guide  6.3 PROGRAMMING EXAMPLES 6.3.1 EXAMPLE I Extract data from the 10th character to the 19th character... The editing format should be configured as follows: 1. Read the “Enter Setup” label to enter the Configuration Mode. 2. Read the “Configure Format 1” label. 3. Read the “Clear All” and “Code 128” labels for applicable code type. 4. Read the “Three Fields” label. 5. Read the “Divide Field 1 by Length” label, and set length to 9. Field 1 data starts from the 1st character to the 9th character. 6. Read the “Divide Field 2 by Length” label, and set length to 10. Field 2 data starts from the 10th character to the 19th character. 7. Read the “Start (Programming)” label to program the transmission sequence. 8. Read the “Field 2” label. 9. Read the “End” label to complete the transmission sequence setting. 10. Read the “End Programming Format” label to complete the setting of Editing Format 1. 11. Read the “Enable Format 1” label to apply Editing Format 1 to Code 128. 12. Read the “Update” label to exit the Configuration Mode.
    167 Update  Chapter 6   Applying Formats for Data Editing  6.3.2 EXAMPLE II Extract the date code, item number, and quantity information from barcodes.   Data in a barcode is encoded like this:    From the 1st character to the 6th character is the date code.    From the 7th character to the dash ‘-’ character is the item number.  After the dash ‘-’ character is the quantity information. Data will be transmitted like this:  The item number goes first, then a TAB character, followed by the date code, then another TAB character, and finally the quantity information.  The editing format should be configured as follows: 1. Read the “Enter Setup” label to enter the Configuration Mode. 2. Read the “Configure Format 2” label. 3. Read the “Three Fields” label. 4. Read the “Divide Field 1 by Length” label, and set length to 6. Field 1 data starts from the 1st character to the 6th character. 5. Read the “Select Field Separator to Divide Field 2” label, and use a dash ‘-’ character. Field 2 data starts from the 7th character until the dash ‘-’ character is met. 6. Read the “Additional Field 1” label, and use a tab character for the field. 7. Read the “Start (Programming)” label to program the transmission sequence. 8. Read the “Field 2”, “Additional Field 1”, “Field 1”, “Additional Field 1”, “Field 3” labels. 9. Read the “End” label to complete the transmission sequence (F2 A1 F1 A1 F3) setting. 10. Read the “End Programming Format” label to complete the setting of Editing Format 1. 11. Read the “Enable Format 2” label to apply Editing Format 2 to all code types. 12. Read the “Update” label to exit the Configuration Mode.
168  End Programming Format 1560 Series Barcode Scanner User Guide
    169 Update    Optical Characteristics  1560  1562 Scan Engine  Non-contact type  Non-contact type Optical Sensor  CCD, 2500 pixels  Laser Light Source  Visible red LED  Visible laser diode RF Characteristics WPAN Module  Wireless PAN BT Class 2 compliance Coverage (line-of-sight)  90 meters with 3656 Interface Supported   Serial Port Profile (BT SPP)  Human Interface Device Profile (BT HID)  3656 Physical Characteristics Memory   4 KB for transmit buffer  512 KB flash for memory mode Switch Tactile switch Weight  Approx. 170 g  Approx. 175 g Color Black  SPECIFICATIONS
170 Enter Setup 1560 Series Barcode Scanner User Guide  Electrical Characteristics Battery  Rechargeable Li-ion battery – 3.7 V, 800 mAh DC 5V ± 5% (with adaptor) Power Adapter Input  AC 100~240 V, 50/60 Hz Output  DC 5V ± 5% (with adaptor via 3656) Environmental Characteristics Temperature Operating Storage 0 °C to 50 °C -20 °C to 60 °C Humidity (Non-condensing) Operating Storage 10% to 90% 5% to 95% Resistance Impact Resistance  1.5 m, 5 drops per 6 sides Electrostatic Discharge    ± 15 kV air discharge, ± 8 kV contact discharge Regulations EMC Regulation  FCC, IC, CE, C-Tick, KCC, NCC, SRMC, TELEC Programming Support Configuration via Setup Labels  Use setup labels or host serial commands. Software Windows®-based ScanMaster Firmware upgradeable  Download firmware updates via the download utility. Accessories (√  means “supported”) Rechargeable Li-ion Battery  √ √ 3656 Stand  √ √ Note: The 3656 stand is not only an Auto-Sense stand (for 1560 only) and capable of charging the 1560/1562 scanner, but specifically designed for the scanner to communicate with a host computer wirelessly.
    171 Update  You can only upgrade firmware of one scanner at a time. For example, you must turn off each of the rest 1560/1562 scanner when there is more than one scanner connected to your computer. Note: In case it fails downloading due to low battery, make sure the targe scanner is loaded with good alkaline batteries and the battery charge is enough. HOW TO UPGRADE 1560/1562 FIRMWARE USING 3656 1) Connect the interface cable, RS-232 or USB, between 3656 and your computer. 2) Connect the power supply cord from 3656 to a proper power outlet. 3) Refer to 3.1.1 Connect to 3656 for the target scanner to connect to 3656. Read the “Set Connection” label first, and then the “Serial Number” label. Both labels can be located at the back of 3656.   4) Read the following labels in sequence to configure the scanner to use RS-232 or USB Virtual COM as output interface.                                           Appendix I FIRMWARE UPGRADE Enter SetupActivate USB Virtual COMUpdateActivate RS-232 115200 bps
172 Enter Setup 1560 Series Barcode Scanner User Guide    5) Read the following labels in sequence for the scanner to enter the download mode. The scanner will respond with beeps to indicate it is ready for downloading.    6) Run the download utility “ProgLoad.exe” on your computer.   1. For the communication settings, select “RS-232” and the correct COM port. For RS-232, select 115200 bps for baud rate. For USB Virtual COM interface, ignore the baud rate setting.   2. For the file option, click [Browse] to select the target file for firmware update — Kernel (K*.shx) or user program (STD*.shx). 3. Click [OK].  7) After upgrading kernel, you will need to manually restart the scanner.           After upgrading the user program, the scanner will automatically restart itself once the download is completed successfully.   Note:  The output interface remains unchanged as specified in step 4 (= RS-232 or USB Virtual COM). For RS-232, the baud rate setting is still 115200 bps!  Enter SetupDownload
    173 Update Appendix I  Firmware Upgrade USING A GENERIC DONGLE 1) Refer to 43.2.3 Connect to Dongle for the target scanner to accept the connection request from your computer. 2) Read the following labels in sequence to configure the scanner to use BT SPP as output interface.       3) Read the following labels in sequence for the scanner to enter the download mode.   The scanner will respond with beeps to indicate it is ready for downloading.      4) Run the download utility “ProgLoad.exe” on your computer.   1. For the communication settings, select “RS-232” and the correct COM port for BT SPP interface, and ignore the baud rate setting.           2. For the file option, click [Browse] to select the target file for firmware update — Kernel (K*.shx) or user program (STD*.shx). 3. Click [OK]. Enter SetupActivate BT SPP (and read labels for PIN code …)UpdateEnter SetupDownload
174 Enter Setup 1560 Series Barcode Scanner User Guide   5) After upgrading kernel, you will need to manually restart the scanner.           After upgrading the user program, the scanner will automatically restart itself once the download is completed successfully.   Note:  The output interface remains unchanged as specified in step 2 (= BT SPP).
    175 Update Appendix I  Firmware Upgrade HOW TO UPGRADE 3656 FIRMWARE UPGRADING 3656 CPU FIRMWARE    1) Connect the interface cable, RS-232 or USB, between 3656 and your computer. 2) Connect the power supply cord from 3656 to a proper power outlet. 3) Refer to 3.1.1 Connect to 3656 for the target scanner to connect to 3656. Read the “Set Connection” label first, and then the “Serial Number” label. Both labels can be located at the back of 3656.   4) Read the following labels in sequence to configure the scanner to use RS-232 or USB Virtual COM as output interface.                                         5) Read the following labels in sequence for 3656 to enter the download mode. The Communication LED on 3656 will be flashing red to indicate it is ready for downloading.                         Enter Setup3656 Download CPU FirmwareEnter SetupActivate USB Virtual COMUpdateActivate RS-232
176 Enter Setup 1560 Series Barcode Scanner User Guide  6) Run the download utility “ProgLoad.exe” on your computer.   1. For the communication settings, select “RS-232” and the correct COM port. For RS-232, select 115200 bps for baud rate. For USB Virtual COM interface, ignore the baud rate setting.   2. For the file option, click [Browse] to select the target file for firmware update (3656*.shx). 3. Click [OK]. 7) The 3656 will automatically restart itself when upgrading firmware is completed successfully. 8) Read the “Update” label for the scanner to resume its operation (exit the configuration mode).                 Update
    177 Update Appendix I  Firmware Upgrade UPGRADING 3656 USB BRIDGE FIRMWARE 1) Connect the USB cable between 3656 and your computer. 2) Connect the power supply cord from 3656 to a proper power outlet. 3) Refer to 3.1.1 Connect to 3656 for the target scanner to connect to 3656. Read the “Set Connection” label first, and then the “Serial Number” label. Both labels can be located at the back of 3656.   4) Read the following labels in sequence to configure the scanner to use USB Virtual COM as output interface.                                    Note:  You can download USB Bridge firmware via USB Virtual COM only! 5) Read the following labels in sequence for 3656 to enter the download mode. The Communication LED on 3656 will be flashing red to indicate it is ready for downloading.       6) Run the download utility “ProgLoad.exe” on your computer.   Enter Setup3656 Download USB Bridge FirmwareEnter SetupActivate USB Virtual COMUpdate
178 Enter Setup 1560 Series Barcode Scanner User Guide  1. For the communication settings, select “RS-232” and the correct COM port for USB Virtual COM interface, and ignore the baud rate setting.          2. For the file option, click [Browse] to select the target file for firmware update (3656*.shx). 3. Click [OK]. 7) The 3656 will automatically restart itself when upgrading firmware is completed successfully. 8) Read the “Update” label for the scanner to resume its operation (exit the configuration mode).   Update
    179 Update  1560/1562 SERIAL COMMANDS D Purpose  To disable the scanner. Remarks  “D” E Purpose  To enable the scanner. Remarks  “E” #@ nnnnnn <CR> Purpose  To configure the scanner. Remarks  nnnnnn – the six digits of command parameters.   For example, “109952” is to list the current Code ID settings.  “0x23” + “0x40” + “0x31” + “0x30” + “0x39” + “0x39” + “0x35” + “0x32” + “0x0d”Note:  After configuring the scanner, you may send the serial command “#@109999” to save the settings. #@ - - - -<CR> Purpose  To halt the scanner. Remarks  “0x23” + “0x40” + “0x2d” + “0x2d” + “0x2d” + “0x2d” + “0x0d” #@ . . . . <CR> Purpose  To resume operation. Remarks  “0x23” + “0x40” + “0x2e” + “0x2e” + “0x2e” + “0x2e” + “0x0d” #@////<CR> Purpose  To respond with a beep. Remarks  “0x23” + “0x40” + “0x2f” + “0x2f” + “0x2f” + “0x2f” + “0x0d”   Appendix II HOST SERIAL COMMANDS Serial CommandList Page 3
180 Enter Setup 1560 Series Barcode Scanner User Guide  #@TRIGOFF<CR> Purpose  To disable the software trigger Remarks  “0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” + “0x46” + “0x46” + “0x0d” #@TRIGON<CR> Purpose  To enable the software trigger Remarks  “0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” + “0x4e” + “0x0d”EXAMPLE You may run HyperTerminal.exe on the host computer to send serial commands to the 1560/1562 scanner via RS-232, USB Virtual COM or BT SPP.  For the scanner to stop immediately –   D  For the scanner to resume working –   E  For the scanner to change the beeper to medium volume and beep –  #@101011<CR> #@////<CR>  For the scanner to change the beeper to minimal volume and beep –   #@101010<CR> #@////<CR>  For the scanner to change the beeper frequency to 8 kHz (for Good Read Beep only) and beep –   #@101001<CR> #@////<CR>  For the scanner to change the beeper length to longest (for Good Read Beep only) and beep –   #@101008<CR> #@////<CR>   For the scanner to save the settings, send the serial command “#@109999” –   #@101011<CR> #@109999<CR> Note:  (1) For RS-232 or USB Virtual COM, you can only configure the first scanner that connects to 3656. To identify the scanner, you may send the serial command to have it respond with a beep.         (2) For BT SPP, you can configure up to seven scanners at the same time.
    181 Update  Appendix II   Host Serial Commands  3656 SERIAL COMMANDS Normally, you can configure the 3656 stand by having a connected scanner read 3656-related setup labels. 1) Connect the interface cable, RS-232 or USB, between 3656 and your computer. 2) Connect the power supply cord from 3656 to a proper power outlet. 3) Refer to 3.1.1 Connect to 3656 for the target scanner to connect to 3656. Read the “Set Connection” label first, and then the “Serial Number” label. Both labels can be located at the back of 3656.   4) Read the following labels in sequence to configure 3656.      For 3656-related setup labels, refer to the Serial Command table below. Note that for the “Version” and “GetID” labels, you must run HyperTerminal.exe or any text editor to receive the information.  If the output interface is USB Virtual COM or RS-232, run HyperTerminal.exe on your computer to receive the information.    If the output interface is USB HID, run any text editor to receive the information. Enter Setup(3656-related setup labels)Update
182 Enter Setup 1560 Series Barcode Scanner User Guide  Config<CR> Purpose  To configure 3656. Remarks  A list of the current settings will be displayed. Run HyperTerminal.exe on your computer and change the settings one by one.  DefaultSetting<CR> Purpose  To restore the default settings. Remarks  SingleConnection<CR> Purpose  To allow only one scanner connecting to 3656. Remarks  MultiConnection<CR> Purpose  To allow up to seven scanners connecting to 3656. Remarks  UseOnePortforAll<CR> Purpose  To use one Virtual COM port for all whenever connecting 3656 to PC via USB. This setting requires you to connect one 3656 at a time, and will facilitate configuring a great amount of 3656 via the same Virtual COM port (for administrators’ or factory use). Remarks
    183 Update  Appendix II   Host Serial Commands  UseVariablePort<CR> Purpose  To use variable Virtual COM port when connecting more than one 3656 to PC via USB. Remarks  Version<CR> Purpose  To get the firmware versions (CPU+USB Bridge). Remarks  GetID<CR> Purpose  To get MAC ID. Remarks  Download<CR> Purpose  To download CPU firmware to 3656 via RS-232 or USB. Remarks  LoadBridge<CR> Purpose  To download USB Bridge firmware to 3656 via USB only. Remarks
184 Enter Setup 1560 Series Barcode Scanner User Guide  EXAMPLE Without using the scanner to read the above setup labels for configuring the 3656 stand, you may run HyperTerminal.exe on the host computer to send serial commands to 3656 via RS-232, USB Virtual COM or HID. 1) Connect the interface cable, RS-232 or USB, between 3656 and your computer. 2) Connect the power supply cord from 3656 to a proper power outlet. The Communication LED will indicate when 3656 can accept serial commands after initializing. Refer to the table below. Communication LED Meaning ---  Blue, solid Initialize Red, solid Blue, flashing Serial command mode with USB Virtual COM or RS-232: wait 3 seconds for starting a serial command Red, flashing Blue, flashing Serial command mode with USB HID: wait 3 seconds for pressing [NumLock] or [CapsLock] 5 times via keyboard  If the output interface is USB Virtual COM or RS-232, run HyperTerminal.exe on your computer. While the Communication LED on 3656 is purple (red with flashing blue), type the serial command within three seconds.  If the output interface is USB HID, press the “NumLock” or “CapsLoack” key on your keyboard 5 times within 3 seconds while the Communication LED on 3656 is flashing red and blue. This will change the interface from USB HID to USB Virtual COM and the Communication LED will become purple (red with flashing blue). Then, run HyperTerminal.exe on your computer. While the Communication LED on 3656 is purple (red with flashing blue), type the serial command within three seconds. After configuring via serial commands, the interface will be reset to USB HID after re-connecting the power supply cord.
    185 Update   0 1 2 3 4 5 6 7 8 0    F2 SP 0 @ P ` p  1  INS F3  !  1  A  Q  a  q   2  DLT F4  "  2  B  R  b  r   3  Home F5  #  3  C  S  c  s   4  End F6 $ 4 D T d t   5  Up F7 % 5 E U e u  6  Down F8  &  6  F  V  f  v   7  Left F9  '  7  G  W  g  w   8  BS F10 (  8 H X h x  9  HT F11 )  9  I  Y  i  y   A  LF F12 * : J Z j  z  B  Right ESC + ; K [ k {  C  PgUp Exec , < L \ l  |  D  CR CR* - = M ] m }  E  PgDn   .  > N ^ n  ~  F  F1   /  ?  O _ o Dly ENTER* Note: (1) ~: Digits of numeric keypad.       (2) CR*/Send/ENTER*: ENTER key on the numeric keypad. KEY TYPE If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable.   Appendix III KEYBOARD WEDGE TABLE *Normal
186 Enter Setup 1560 Series Barcode Scanner User Guide   KEY STATUS Decide whether or not to change key status when “Normal Key” is selected for Key Type.                                                                        USER-DEFINED SCAN CODE 1) Read the “Set Scan Code” label to define new scan code.  2) Read the “Hexadecimal Value” label on page 188 for the desired character string.   3) Read the “Validate” label to complete this setting. 4) Read the “Confirm” label to confirm the action.    Scan CodeSet Scan CodeConfirmAdd Shift Add Left CtrlAdd Right Ctrl Add Left AltAdd Right Alt
    187              Update AbortDECIMAL SYSTEM Decimal                Validate the Values                                           Appendix IV NUMERAL SYSTEMS 0 1 2 3 4 5 6 7 8 9 Validate
188 Enter Setup 1560 Series Barcode Scanner User Guide  HEXADECIMAL SYSTEM Hexadecimal                         0 1 2 3 4 5 6 7 8 9 A B C D E F
    189              Appendix IV  Numeral Systems  Update AbortValidate the Values  ASCII TABLE   0 1 2 3 4 5 6 7  0    DLE SP 0 @ P ` p  1  SOH DC1 !  1  A  Q  a  q   2  STX DC2 "  2  B  R  b  r   3  ETX DC3 # 3 C S c s  4  EOT DC4 $ 4 D T d t   5  ENQ NAK % 5 E U e u  6  ACK SYN &  6  F  V  f  v   7  BEL ETB '  7  G  W  g  w   8  BS CAN (  8 H X h x  9  HT EM )  9  I  Y  i  y   A  LF SUB * : J Z j  z  B  VT ESC + ; K [ k {  C  FF FS , < L \ l  |  D  CR GS - = M ] m }  E  SO RS .  > N ^ n  ~  F  SI US /  ? O _ o DEL         Validate
190 Enter Setup 1560 Series Barcode Scanner User Guide  ENTERING PIN CODE FOR AUTHENTICATION USE PRESET PIN 1) In the configuration mode, read the label below to use a preset PIN for authentication.    2) Read one of the labels to specify the PIN code, in decimal or hexadecimal.   By default, the PIN code is set to “0000”. Maximum 16 characters are allowed.                                                                3) Read the “Decimal Value” label on page 187 or the “Hexadecimal Value” label on page 188 for the desired digits or character string.   Read the “Clear PIN Code” label first if you need to re-input the PIN code.     4) Read the “Validate” label to complete this setting.    Use preset PINClear PIN CodeEnter PIN Code in Hexadecimal … Enter PIN Code in Decimal …
    191              Appendix IV  Numeral Systems  Update AbortDISABLE AUTHENTICATION OR USE RANDOM PIN In the configuration mode, read the label below to disable authentication (= No PIN) or use a random PIN for authentication.    Note:  When using BT HID, some device driver may not support pre-defined PIN code for authentication. In this case, make sure you have the scanner set to “No PIN or use random PIN” before pairing. While pairing, the host PIN code will be displayed on the computer screen. Use Random PIN When the target device is set to use a random PIN for authentication, wait until the random PIN is displayed on the target device while pairing, and then input the matching PIN code on the scanner. Note:  Follow the steps below to enter the matching PIN on the scanner. There is no need to enter the configuration mode! 1. Read one of the labels to specify the PIN code, in decimal or hexadecimal.                                                               2. Read the “Decimal Value” label on page 187 or the “Hexadecimal Value” label on page 188 for the desired digits or character string. Read the “Clear PIN Code” label first if you need to re-input the PIN.   3. Read the “Validate” label to complete this setting.   *No PIN or  use random PINEnter PIN Code in Hexadecimal … Enter PIN Code in Decimal … Clear PIN Code
192 Enter Setup 1560 Series Barcode Scanner User Guide   Reject Random PIN Request When the random PIN is displayed on the target device while pairing, you can reject the PIN request by having the scanner read the “Validate” label.

Navigation menu