CipherLab ID-20 RFID READER MODULE User Manual

CipherLab Co., Ltd. RFID READER MODULE Users Manual

Users Manual

Download: CipherLab ID-20 RFID READER MODULE User Manual
Mirror Download [FCC.gov]CipherLab ID-20 RFID READER MODULE User Manual
Document ID592095
Application IDPZmPitISahRb5NfA+9ITWg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize53.49kB (668591 bits)
Date Submitted2005-10-14 00:00:00
Date Available2005-10-05 00:00:00
Creation Date2005-10-05 03:53:52
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2005-10-14 22:25:50
Document TitleUsers Manual

5000/5100
Reference Manual
Version 1.02
Oct. 5, 05
Reserved.
This page is a reverse of the preceding page; they are for identifying a draft version.
When the document is converted to PDF, they are to be replaced by the designed
cover and a blank page. To identify version of a PDF document, use the stamp tool.
(Draft / Final / For Public Release / Revised … etc.)
STATEMENTS
Copyright
© Syntech Information Co., Ltd. 2004 All rights reserved.
This document, as well as any software included, may not be reproduced, stored in
retrieval system or transmitted, in any form or by any means, without prior written
consent of the copyright owners.
Trademark
The
logo is a registered trademark of Syntech Information Co., Ltd.
Disclaimer of Liability
Efforts have been made to ensure the accuracy of the information presented in this
document. In the interest of improving internal design, operational function, and/or
reliability, Syntech reserves the right to make changes to the products described in this
document without prior notice. Syntech does not assume any liability that may occur
due to the use or application of the product(s) or circuit layout(s) described herein.
Technical Support
For product consultancy and technical questions, please contact your local sales
representative. For more information, please visit our website.
http://www.cipherlab.com
Statements
Statements:
FCC Regulations & Technical Standards
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Statements
FEDERAL COMMUNICATIONS COMMISSION
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:(1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Limited Module Approval Statement:
This device is intended only for OEM Integrators. The OEM integrator should
be aware of the following important issues.
Labeling of the End Product
The end product integrate this module has to be clearly identified on the label
that this end product contains a FCC approved RF module. The format of
such statement could “Contain Tx FCC ID: Q3N-ID-20” or similar.
Integration Note
The transmitter module may not be co-located with any other transmitter or
antenna.
The OEM integrator is responsible for testing their
end-product for any additional compliance requirements required with this
module installed (for example, digital device emission, PC peripheral
requirements, etc.)
In the event that these conditions can not be met, then the FCC authorization
is no longer considered valid and the FCC ID can not be used on the final
product (including the transmitter) and obtaining a separate FCC authorization.
CONTENTS
PREFACE ...................................................................................................V
CARE & MAINTENANCE .............................................................................. 1
GETTING READY ........................................................................................ 2
1. INTRODUCING 5000/5100....................................................................... 3
1.1 Product Highlights ............................................................................................. 3
1.2 Nomenclature...................................................................................................... 4
1.2.1 Inside Enclosures ...................................................................................... 5
1.2.2 Dimensions................................................................................................ 6
1.3 Features .............................................................................................................. 7
1.3.1 Power ........................................................................................................ 7
1.3.2 CPU........................................................................................................... 9
1.3.3 Memory & Calendar ................................................................................... 9
1.3.4 Keyboard ................................................................................................. 11
1.3.5 LCD ......................................................................................................... 12
1.3.6 Status LEDs............................................................................................. 13
1.3.7 Buzzer ..................................................................................................... 13
1.3.8 Readers ................................................................................................... 13
1.3.9 Ethernet ................................................................................................... 14
1.3.10 Programming Support............................................................................ 15
1.4 Unpacking the package .................................................................................... 16
1.5 Options .............................................................................................................. 16
Table of Contents
Contents:
Section 2 ~4.3
2. INSTALLING 5000/5100........................................................................ 17
2.1 Setting up the terminal ..................................................................................... 17
2.2 Wiring................................................................................................................ 22
2.2.1 Pin Assignments ...................................................................................... 23
3. SYSTEM ARCHITECTURE....................................................................... 25
3.1 Operation .......................................................................................................... 26
3.2 Download .......................................................................................................... 27
3.3 Management ..................................................................................................... 28
4. CONFIGURING 5000/5100 .................................................................... 29
4.1 Identifying current menu ................................................................................. 29
4.2 Selecting from menus ....................................................................................... 30
4.3 System Menu..................................................................................................... 32
4.3.1 Information............................................................................................... 33
4.3.2 Settings.................................................................................................... 34
4.3.3 Tests........................................................................................................ 38
4.3.4 Memory.................................................................................................... 40
4.3.5 Power ...................................................................................................... 41
4.3.6 Load Program .......................................................................................... 42
4.3.7 NET Menu ............................................................................................... 43
Tables of Contents
Contents:
Section 4.4 ~
4.4 Program Manager ............................................................................................ 49
4.4.1 Download................................................................................................. 50
4.4.2 Activate.................................................................................................... 53
4.4.3 Version .................................................................................................... 54
4.5 Kernel Menu ..................................................................................................... 55
4.5.1 Information............................................................................................... 56
4.5.2 Load Program .......................................................................................... 57
4.5.3 Kernel Update.......................................................................................... 58
4.5.4 Test & Calibrate ....................................................................................... 58
5. MANAGING 5000/5100......................................................................... 59
5.1 For proprietary applications ............................................................................ 60
5.2 For custom applications ................................................................................... 60
SPECIFICATIONS ...................................................................................... 61
TROUBLESHOOTING ................................................................................. 63
APPENDIX I – MOUNTING TEMPLATE ......................................................... 65
Table of Contents
Contents:
Tables
Table 1: Power consumption .............................................................................. 8
Table 2: Memory explained................................................................................. 9
Table 3: Keypad explained ............................................................................... 11
Table 4: Display formats ................................................................................... 12
Table 5: Types of readers ................................................................................. 13
Table 6: Decide resistance value ....................................... 錯誤! 尚未定義書籤。
Table 7: Optional accessories........................................................................... 16
Table 8: Stages of installation........................................................................... 17
Table 9: Types of interfaces............................................... 錯誤! 尚未定義書籤。
Table 10: Pin Assignment of JP2 ...................................................................... 23
Table 11: Pin Assignment of JP3 ...................................................................... 24
Table 14: Purposes of software modules/menus .............................................. 26
Table 15: Application programs ........................................................................ 27
Table 16: Management programs ..................................................................... 28
Table 17: Function keys used in selecting from menus..................................... 30
Table 18: Default system settings ..................................................................... 34
Table 19: Downloading interfaces..................................................................... 42
Table 20: Listing of multiple programs and font................................................. 50
Table 21: Downloading spare programs ........................................................... 51
Table 22: Downloading active program or font.................................................. 52
Table 23: Device code explained ...................................................................... 56
List of Tables
Contents:
Figures
Figure 1: References for setting up system......................................................... 2
Figure 2: Nomenclature of terminal..................................................................... 4
Figure 3: Components inside terminal................................................................. 5
Figure 4: Physical dimensions ............................................................................ 6
Figure 5: Installing battery pack ......................................... 錯誤! 尚未定義書籤。
Figure 6: Installing memory card....................................................................... 10
Figure 7: Keypad layout .................................................................................... 11
Figure 12: An example for Ethernet networking ................................................ 14
Figure 13: Installing Ethernet card .................................................................... 15
Figure 14: Drilling holes & assembling cables................................................... 18
Figure 15: Mounting to wall............................................................................... 19
Figure 16: Wiring & connecting ......................................................................... 20
Figure 17: Assembling enclosures .................................................................... 21
Figure 18: Terminal blocks................................................. 錯誤! 尚未定義書籤。
Figure 20: Terminator’s switch ........................................... 錯誤! 尚未定義書籤。
Figure 22: System Architecture......................................................................... 25
Figure 23: Function keys as menu indicators .................................................... 31
Figure 24: System Menu................................................................................... 32
Figure 25: Program Manager menu .................................................................. 49
Figure 26: Kernel Menu .................................................................................... 55
Figure 27: Remote management ...................................................................... 59
Figure 28: Mounting template ........................................................................... 65
List of Figures
Contents:
Sample Screens
Screen 1: Status lights as menu indicators ....................................................... 29
Screen 2: System Menu> 1. Information ........................................................... 33
Screen 3: System Menu> 2. Settings................................................................ 34
Screen 4: System Menu> 2. Settings> 1. Clock ................................................ 34
Screen 5: System Menu> 2. Settings> 2. Backlight Period ............................... 35
Screen 6: System Menu> 2. Settings> 3. CPU Speed ...................................... 35
Screen 7: System Menu> 2. Settings> 4. Key Click .......................................... 36
Screen 8: System Menu> 2. Settings> 5. System Password............................. 36
Screen 9: System Menu> 2. Settings> 6. Font.................................................. 37
Screen 10: System Menu> 3. Tests .................................................................. 38
Screen 11: System Menu> 4. Memory.............................................................. 40
Screen 12: System Menu> 5. Power................................................................. 41
Screen 13: System Menu> 6. Load Program .................................................... 42
Screen 14: System Menu> 7. Net Menu ........................................................... 43
Screen 15: System Menu> 7. Net Menu> 1. Information................................... 43
Screen 16: System Menu> 7. Net Menu> 2. IP Setting ..................................... 45
Screen 17: System Menu> 7. Net Menu> 3. Echo Tests................................... 46
Screen 18: System Menu> 7. Net Menu> 3. Echo Tests: Client Mode .............. 47
Screen 19: System Menu> 7. Net Menu> 4. Download via TCP/IP................... 48
Screen 20: Program Manager> 1. Download .................................................... 50
Screen 21: Program Manager> 2. Activate ....................................................... 53
List of Screens
PREFACE
The 5000/5100 stationary batch terminals are intended for versatile data collection
applications with its large and expandable database capacity, and allow programmable
solutions to meet varying needs of customers. Various operational parameters can be
configured, such as backlight control, buzzer control, graphic screen and output
format.
Integrated with a proximity reader and backlit keypad, the 5000 terminal simply
satisfies general needs regarding large data collection. Based on the 5000 terminal,
the 5100 terminal comes with a backlit LCD for displaying information. Alternatively,
both models can make use of a battery pack for achieving a non-interruptible operation
during power outage. Without such power backup, the terminals will not function during
a power fail, but all transaction and configuration data stored in memory will be
maintained by the 3V lithium button cell for at least one week.
The 5000/5100 terminals can be easily added to your legacy networks. Networking
options include 10/100Base-T Ethernet. Moreover, detachable terminal blocks make it
easy and flexible to connect with other external devices, such as a reader, door switch,
siren, door sensor, electronic lock, etc.
This manual serves to guide you through how to install, configure, and operate the
5000/5100 terminals. The Care & Maintenance section is specifically prepared for
those who are in charge of taking care of the terminals.
We recommend you to keep one copy of the manual at hand for quick reference or
maintenance purposes. To avoid any improper disposal or operation, please read the
manual thoroughly before use.
Thank you for choosing the CipherLAB products!
CARE & MAINTENANCE
This is specifically prepared for those who are in charge of taking care of the terminals,
such as a terminal operator or maintenance engineer.
Here are some tips on how to take care and maintain the terminals.
Taking care of the terminal
Always keep electric equipments like the terminals away from any flammable
sources.
Always make sure there is stable power supply for the terminal to operate
properly.
This terminal is intended for indoor use. It may do damage to the terminals when
being exposed to extreme temperatures or soaked wet.
When the body of the terminal gets dirty, use a clean and wet cloth to wipe off the
dust. DO NOT use/mix any bleach or cleaner. Always keep the LCD dry.
For a liquid crystal display (LCD), DO NOT use any pointed or sharp objects to
move against the surface.
Maintaining the terminal
If you want to put away the terminal for a period of time, download the collected
data to a host first, and then take out the battery pack. Store the terminal and
battery pack separately.
When the terminal resumes its work, the rechargeable main and backup batteries
will take a certain time to become fully charged.
If you shall find the terminal malfunctioning, refer to the Troubleshooting section
for self help first.
If the problem persists, please write down the specific scenario and consult your
local sales representative.
In no circumstances, users are allowed to repair components.
GETTING READY
If you are using the terminal for the first time, the illustration below gives outline of the
system and section references.
Access to the configuration menus needs to disconnect the external and internal
power connection of the terminal first. Therefore, we suggest that you do all the
configuration and downloading jobs before setting up the system on site.
Figure 1: References for setting up system
1. INTRODUCING 5000/5100
This section mainly explains the hardware construction and features of the 5000/5100
terminals. The 5100 terminal looks similar to the 5000 terminal except for the screen.
1.1 Product Highlights
2, 4 or 8 MB for expandable data memory, powered by backup cell
Graphic LCD supports double-byte languages
Tamper switch to activate the buzzer during removal of enclosures
4 Digital Input & 4 Digital Output for monitoring/controlling external devices
Programmable signals to accommodate custom applications
Programming support: OCX, BASIC and C
Introducing 5000/5100:
Nomenclature
1.2 Nomenclature
The pictures below show the major components:
Figure 2: Nomenclature of terminal
Introducing 5000/5100:
Nomenclature
1.2.1 Inside Enclosures
Figure 3: Components inside terminal
Introducing 5000/5100:
Nomenclature
1.2.2 Dimensions
These drawings provide 3-sided views with dimensions, which are helpful in choosing
a suitable location for installation.
Figure 4: Physical dimensions
Introducing 5000/5100:
Features
1.3 Features
1.3.1 Power
Line Power
A 12 V/ 1000 mA wall adaptor is used to power the 5000/5100 terminals.
Introducing 5000/5100:
Features
Power Consumption Status
The System Menu provides information on power consumption.
Monitor voltage level: Line / Main / Backup
>> Also see Section 4.3.5 Power
For the 5100 terminal, the smart battery icon will replace the plug icon on the screen
when it is battery-operated. Here is another way to tell a low or discharged main
battery from the screen.
Examine the levels of the smart battery icon
Utilizing the low voltage/power technology, the terminal draws very little power. The
power consumption is estimated in different conditions as follows:
EM reader –
backlight off:
backlight on:
backlight on, charging:
55
125
240
mA @ +12V
mA @ +12V
mA @ +12V
Table 1: Power consumption
It can be easily seen that there are still some rooms for the adaptor’s supply capability.
However, it is strongly recommended to use other supplies to power heavy loads such
as door locks, alarms and so on. Also, if possible, keep these heavy loads electrically
isolated from the terminal. Electronic equipments such as the terminal tend to be
upset by surges from surrounding “noisy” devices.
Introducing 5000/5100:
Features
1.3.2 CPU
A 16-bit low power CMOS CPU is utilized. With little current consumed, yet, this CPU
can run under 22.1184MHz and provide more than 6 MIPS of computation powers.
1.3.3 Memory & Calendar
An optional memory card upgrades memory to 2, 4, or 8 Mbytes SRAM with its own
contents backup button cell. The DIP switch on the card must be set ON for the cell to
work.
Program memory:
2 Mbytes flash memory for core, OS, application software, fonts, etc.
Data memory:
256 Kbytes SRAM with contents backup by a 7 mAh rechargeable Li button cell.
Calendar:
A calendar chip is also equipped for accurate time/date logging.
Non-stop operation is also provided through the same Li button cell for SRAM
contents backup.
Table 2: Memory explained
Introducing 5000/5100:
Features
Installing Memory Card
1. Align pinholes at the back of the card to the pins on the main PCB.
2. Press down the card flatly. Be careful not to bend or distort any pins.
3. Then apply the screw to screw down to the pole.
Figure 6: Installing memory card
10
Introducing 5000/5100:
Features
1.3.4 Keyboard
A 21-key keypad is for system setup, user entry and so on.
Figure 7: Keypad layout
Silicon rubber has been chosen for their durability and prompt feedback. The key click
can be configured through the System Menu.
>> Also see Section 4.3.2 Settings
These keys can be categorized into two groups:
Function keys (F1~F6):
User-definable, each comes with a GREEN LED underneath.
Can be used to show the current system status such as working shifts, etc.
Also, in combination with the graphic LCD, user-friendly graphic selection menu
can be implemented.
Alphanumeric keys:
The alphanumeric keypad layout is similar to phone keypad, and also with GREEN
LED backlight. Default input mode is numeric.
Capital letters mode: press the Alpha key once and A appears on the screen.
Small letters mode: press the Alpha key twice and a appears on the screen.
Table 3: Keypad explained
11
Introducing 5000/5100:
Features
Optional External Keyboard
The 5000/5100 terminals provide one keyboard port. You may connect an external
keyboard to this port.
1. Connect wires from the keyboard module to the receptacle on the main PCB.
2. Connect the external keyboard to the PS/2 port.
1.3.5 LCD
The 5100 terminal comes with a 128 by 64 pixels FSTN graphic LCD, which is able to
display message in formats as follows:
English fonts:
Chinese fonts:
Other language fonts, company logo, etc.
(6×8 pixels)
21 by 8 lines
(8×16 pixels)
16 by 4 lines
(16×16 pixels)
8 by 4 lines
Programmable
Table 4: Display formats
The LED backlight helps ease reading under dim environments, and can be
configured through the System Menu.
>> Also see Section 4.3.2 Settings
Also, other language fonts, company logo and so on can be shown to accommodate
varying application needs.
12
Introducing 5000/5100:
Features
1.3.6 Status LEDs
There are four indicators on the front panel for status feedback. They are
programmable for diagnostics and application dependant.
Red LED
Green LED
Yellow LED
Orange LED
– Power
– Good Read
– 485 Comm.
– Host Comm.
1.3.7 Buzzer
The buzzer is a low power transducer type, and its pitch and duration are software
programmable.
1.3.8 Readers
Two types of readers are supported:
125 KHz EM:
From contact to 6 cm
Table 5: Types of readers
A second reader can be attached via the JP2 “external reader port”. Please note that
these are “CMOS level” (0~+5V) signals. A +5V output is also available on the JP2
and can be used to power this external reader.
13
Introducing 5000/5100:
Features
1.3.13 Ethernet
An optional 10/100 Base-T Ethernet card can be attached to merge the terminals onto
any existing legacy Ethernet networks. It comes with a standard RJ-45 connector and
is fully standard compliant. Just like the RS-485, the IP address must be set
accordingly.
Figure 12: An example for Ethernet networking
14
Introducing 5000/5100:
Features
Installing Ethernet Card
You may have to install the Ethernet card to the terminal by yourself. If you have
installed a memory card, attach the Ethernet card on top of it then.
1. Align the pinholes at the back of the card to the pins on the main PCB.
2. Press down the card flatly. Be careful not to bend or distort any pins.
3. Then apply the screw to screw down to the pole.
Figure 13: Installing Ethernet card
1.3.14 Programming Support
For custom applications, development tools include BASIC and C compliers.
In addition, OCX support is also available for proprietary 5100*.SHX application
programs.
15
Introducing 5000/5100:
Unpacking & Options
1.4 Unpacking the package
The following items are included in the package. Save the box and packaging material
for future use when you need to store or ship the terminal.
The 5000 or 5100 Terminal
Power Adaptor
Software CD & Reference Manual (for authorized distributors only)
1.5 Options
There are several optional accessories to enhance the total performance of the
terminals. Some of them may be ordered separately, and therefore, require you to
install them to the main PCB by yourself.
For installation details, please refer to relevant sections.
Memory card:
2, 4 or 8 MB SRAM for data memory
Reader:
Built-in RFID reader EM type
Ethernet card:
RJ-45 port for 10/100Base-T Ethernet networking
Table 7: Optional accessories
16
2. INSTALLING 5000/5100
2.1 Setting up the terminal
The whole installation can be simply classified into the following stages:
Site Survey:
Choose a location that is close to the target door and provides clearance for the cables
and access to an AC outlet.
Mounting:
Drill holes on the wall.
Mount the lower enclosure on the wall.
Attaching:
Attach optional accessories to the PCB.
Wiring & Connecting:
Connect wires to terminal blocks.
Connect connectors to receptacles.
Connect to Ethernet networks.
Assembling:
Secure enclosures.
Power Supplying:
Connect to an appropriate wall outlet.
Table 8: Stages of installation
The site survey should take both location and topology into consideration. And the
actions specified for each stage should be taken with care to avoid any damages to
the terminals or peripherals.
To ensure proper wiring and safe operation, we strongly recommend that the terminals be
set up by an experienced electrician.
17
Installing 5000/5100:
Setting up the terminal
Figure 14: Drilling holes & assembling cables
Drilling Holes & Assembling Cables
1. Make use of the mounting template provided in the appendix, and drill four holes
in an appropriate location for installing the terminal:
Each hole shall be 6 mm in diameter and 21 mm in depth.
The four holes enclose a square of 120 mm x 120 mm.
2. Insert the four wall plugs (screw anchors for concrete surface) into the four holes.
Make sure each of them is completely inside a hole.
. Apply the two-piece cable holder
3. Pull cables through the cable entry hole
to organize the in-coming cables, and secure the holder to the pole
by screw.
18
Installing 5000/5100:
Setting up the terminal
Figure 15: Mounting to wall
Mounting to the Wall
4. Make sure the cables are routing and arranged in the cable channel at the back.
Such design is to keep cables invisible and inaccessible from the outside.
5. Apply four 4x16 screws to mount the lower enclosure on the wall.
Attaching Optional Items
6. Attach the memory card and Ethernet card, if there is any.
>> Also see Sections 1.3 Features & 1.5 Options
19
Installing 5000/5100:
Setting up the terminal
Figure 16: Wiring & connecting
Wiring & Connecting
7. Attach connectors of the keyboard module, reader module, charger or battery
pack to receptacles on the PCB.
8. Follow the wiring instructions to insert every wire to a corresponding slot of the
. Tighten screws to secure wires. Then plug the terminal block
terminal blocks
in to the PC board socket.
Connect line power.
Connect digital inputs and outputs.
Connect RS-232, if necessary
Connect RS-485, if necessary
9. If the Ethernet card
is installed, simply connect a standard networking cable
(two ends with RJ-45 connectors) to the Ethernet ports on the module and your
networking device.
Proceed to enable TCP/IP and set other networking parameters.
20
Installing 5000/5100:
Setting up the terminal
Figure 17: Assembling enclosures
Assembling Enclosures from Bottom to Top
10. Make sure there is no more need to do hardware configuration and/or
downloading application program.
At last, position the two tabs at the bottom of the upper enclosure into the notches
at the bottom of the lower enclosure. The two pieces of enclosures snap to fit.
11. Apply two M2x6 screws to secure the upper enclosure to the lower enclosure on
top.
Connecting to Power
12. Connect the power adaptor to an outlet.
When being installed for the first time, both the battery pack and the button cell for memory
backup take a certain time to be fully charged.
21
Installing 5000/5100:
Wiring
2.2 Wiring
22
Installing 5000/5100:
Wiring
2.2.1 Pin Assignments
The pin assignments are listed and described below.
JP2:
Pin No. Name
GND
GND
Category
Power
Power
Description
Ground
Ground
Table 10: Pin Assignment of JP2
23
Installing 5000/5100:
Wiring
JP3:
Pin No. Name
Category
18
Vsys
System power
19
Vsys
System power
Table 11: Pin Assignment of JP3
24
Description
+12V (from adaptor) or main
battery
+12V (from adaptor) or main
battery
3. SYSTEM ARCHITECTURE
The whole system can be simplified as hardware and software at PC end and terminal
end. The software inside the terminal mainly consists of three modules: Kernel,
System, and Program. For system configurations and managing multiple programs,
each terminal comes with System Menu, Kernel Menu, and Program Manager.
Figure 22: System Architecture
Program Manager Menu, which is generated by 51pm.shx, is unavailable by default.
Please download 51pm.shx in the System Manu first.
25
System Architecture:
Operation
According to different purposes for which the modules serve, the software inside the
terminal also can be viewed in the following way:
Menus
Purposes
Setup Menu
OR
User-defined menu
Setup Menu is generated by the proprietary 5100*.SHX
program. The menu functions and access keys depend on
the application program you download to the terminal.
System Menu
A portal to system configurations.
Kernel Menu
Generally, this is for manufacturing use only.
Program Manager
A portal to manage multiple programs.
Table 14: Purposes of software modules/menus
Because the 5000 terminal comes without the LCD screen, we suggest you keep the
manual at hand while configuring the terminals.
3.1 Operation
After being properly configured and physically set up together with peripherals, the
terminal is ready to work when a corresponding management utility is ready at PC
end.
Applications scope include Access Control system, Time & Attendance, Shop Floor
Control, etc. It depends on which application program is running.
Proper configuration is very important for a system that consists of a number of terminals.
26
System Architecture:
Download
3.2 Download
The terminal must be configured correctly for downloading either of the following:
Program update
New application program
Proprietary Application Programs (5100*.SHX):
The following programs have been developed to meet varying application needs.
One of them is preloaded inside the terminal.
Access Control: 5100AC-MS-V1.0.SHX
Time & Attendance: 5100T&A-V1.0.SHX
Shop Floor (Work-in-Process, WIP): 5100SF-V1.0.SHX
Corresponding to each of these programs, a Setup Menu is available on the terminal
for setting parameters.
Alternatives:
Aided by programming support, user-defined application programs can be developed
to satisfy specific needs as being part of a system.
Table 15: Application programs
27
System Architecture:
Management
3.3 Management
Install a management utility at PC end that corresponds to the current application.
Then, proceed to define the environments for the terminal to work.
Please see programming guide for details.
The terminal must be loaded with an appropriate application first.
Proprietary Management Software for 5100*.SHX:
The software is in correspondence to proprietary application programs.
Several PC end utilities are available for remote management. For example,
Menjin.exe is for access control system.
Aided by OCX support, customized management utilities can be developed.
Command sets are mainly for managing the terminals. Yet, sending commands
from a host can do part of the configuration as well.
Alternatives:
The custom management software is specifically in correspondence to user-defined
application programs.
Table 16: Management programs
28
4. CONFIGURING 5000/5100
This section mainly describes the alternatives to configure the 5000/5100 terminals,
including hardware configuration and downloading application programs.
Although the 5000 terminal is not equipped with a screen, you may proceed with
configurations by following the LED indicators and relevant sample screens of menus
in this manual.
Without a screen, some menus are not operational on the 5000 terminal.
4.1 Identifying current menu
With or without a screen, the LEDs on the front panel will indicate the current layer of
menus when configuring settings.
Screen 1: Status lights as menu indicators
29
Configuring 5000/5100:
Selecting from menus
4.2 Selecting from menus
The function keys can also be used in selecting item from menus on the screen.
To select item 1 to 5 on any menu, simply press [F1] to [F5].
To select item 6 on any menu, press [F6] then [F1].
To select item 7 on any menu, press [F6] then [F2].
F1
1 + [Enter]
F2
2 + [Enter]
F3
3 + [Enter]
F4
4 + [Enter]
F5
5 + [Enter]
F6
Next page
F6 followed by F1
6 + [Enter]
F6 followed by F2
7 + [Enter]
Table 17: Function keys used in selecting from menus
30
Configuring 5000/5100:
Selecting from menus
Figure 23: Function keys as menu indicators
31
Configuring 5000/5100:
System Menu
4.3 System Menu
The System Menu is generated by a powerful utility, which offers an interface for
engineers (programmers or system integrator) to view system information, change the
configuration parameters, manage files and run diagnostics.
This menu is designed for engineering tests and maintenance ONLY. For this reason,
the System Menu provides password protection to prevent unauthorized users from
accidentally changing system settings.
Warning! The System Menu is NOT for the use of any end users.
The system password helps ensure system safety and integrity.
How to access the System Menu?
1. Lift the upper enclosure by unscrewing the two screws on top of the terminal.
2. Disconnect BOTH the line power and main battery.
3. Re-connect the main battery and simultaneously press [5] + [7] + [9] from the
keyboard.
4. The System Menu is displayed on the LCD screen as shown below.
5. Re-connect the line power when configuration is done.
* Net Menu is available only when Ethernet card is present.
Figure 24: System Menu
32
Configuring 5000/5100:
System Menu
4.3.1 Information
Screen 2: System Menu> 1. Information
The information provided here helps diagnose the system.
H/W:
Hardware version (PCB)
S/N:
Serial number of the terminal
M/D:
Manufacturing date
KNL:
Kernel version
LIB:
C library version
USR:
Application program version
DEV:
Code for optional hardware configurations, i.e. 1700.
See Kernel> Information for device code.
NET:
Serial number of Ethernet card if installed
Without a screen, this is not available on the 5000 terminals.
33
Configuring 5000/5100:
System Menu
4.3.2 Settings
Screen 3: System Menu> 2. Settings
Here provides options to change the default settings.
System settings
Clock
N/A
Backlight Period
20 seconds
CPU Speed
Full speed
Key Click
Tone 2
System Password
Open access
Font
System font
Table 18: Default system settings
Settings > Clock
Set date and time for Real Time Clock.
Enter two digits for the year, i.e. 04 for 2004.
Screen 4: System Menu> 2. Settings> 1. Clock
34
Default values
Configuring 5000/5100:
System Menu
Settings > Backlight Period
Set the backlight duration for the keypad and LCD.
Enter a value between 0 and 99999.
Screen 5: System Menu> 2. Settings> 2. Backlight Period
Settings > CPU Speed
Set the CPU speed to save power if necessary. The current value is highlighted.
Options include: Full, Half, Quarter, Eighth and Sixteenth.
Screen 6: System Menu> 2. Settings> 3. CPU Speed
35
Configuring 5000/5100:
System Menu
Settings > Key Click
There is audible feedback for pressing a key on the keypad.
The current value is highlighted. Select a tone for the buzzer or mute it.
Screen 7: System Menu> 2. Settings> 4. Key Click
Settings > System Password
Set a password to control user access to the System Menu.
The password consists of eight characters at most.
To disable a previous password, enter blank on the following screens.
Screen 8: System Menu> 2. Settings> 5. System Password
36
Configuring 5000/5100:
System Menu
Settings > Font
Current font information can be viewed here.
Default: System font
Custom font file, if there is one
The font settings here can be changed if a multi-languages font file has been
downloaded. (Press [2] / [8] to move down / up the menu of options.)
Screen 9: System Menu> 2. Settings> 6. Font
Without a screen, this is not available on the 5000 terminals.
37
Configuring 5000/5100:
System Menu
4.3.3 Tests
Screen 10: System Menu> 3. Tests
Here provides functional tests for key parts:
Tests > Memory
Test the data memory (SRAM), and the results will be shown on the screen.
Press any key to exit.
Without a screen, this is not available on the 5000 terminals.
Warning! The contents of the data memory (SRAM) will be wiped out after test.
Tests > Buzzer
Test the buzzer with different frequency/duration combinations.
Press [Enter] to start. Press any key to stop and exit the test.
38
Configuring 5000/5100:
System Menu
Tests > LCD & LED
Test the LCD display and LED indicator.
Press [Enter] to start. Press any key to stop and exit the test.
You may only be able to test the LED indicators on the 5000 terminals.
Tests > Keyboard
Test the rubber keys.
Press any key and its corresponding character will be shown on the screen.
Press [ESC] to stop and exit the test.
Without a screen, this is not available on the 5000 terminals.
Tests > RFID
Test the reading performance of the RFID reader when a proximity card is present.
Press [ESC] to stop and exit the test.
Without a screen, this is not available on the 5000 terminals.
39
Configuring 5000/5100:
System Menu
4.3.4 Memory
Screen 11: System Menu> 4. Memory
Memory > Size information
Here provides information regarding the data and program memory:
Base RAM
Memory Card
Flash
(SRAM for data memory)
(SRAM for data memory)
(for program memory)
Without a screen, this is not available on the 5000 terminals.
Memory > Initialize
Perform task initializing the data memory (Base RAM or Memory Card).
Warning! The contents of the data memory (SRAM) will be wiped out after memory
initialization.
40
Configuring 5000/5100:
System Menu
4.3.5 Power
Screen 12: System Menu> 5. Power
Here shows current voltage consumption for Line / Main / Backup.
Line:
Line power (DC) status.
Main:
Main battery status.
The battery pack is a standby power source when line power is down.
Backup: Backup battery status.
The button cell is used to retain data in SRAM and maintain RTC.
Without a screen, this is not available on the 5000 terminals.
41
Configuring 5000/5100:
System Menu
4.3.6 Load Program
Screen 13: System Menu> 6. Load Program
The terminal must be configured correctly for downloading either of the following:
Program update
New application program
Interfaces:
Ethernet
See System Menu> Net Menu> Download via TCP/IP
Table 19: Downloading interfaces
Results
Success: the new program or font file will be activated right after downloading.
Failure: the terminal will resume to the current application program or font
42
Configuring 5000/5100:
System Menu
4.3.7 NET Menu
Screen 14: System Menu> 7. Net Menu
This submenu is for IEEE 802.3 10/100Base-T Ethernet networking, and is available
only when an Ethernet card is installed. Parameters must be configured correctly.
The menu can only be shown when the 5kTCPIP.LIB is linked.
Net Menu > Information
Information of network configuration can be viewed here.
LIB:
MAC:
DHCP:
IP:
Mask:
Gate:
Version of 5KTCPIP.LIB
MAC ID of the installed Ethernet (TCP/IP) module
DHCP being enabled or disabled
IP address of the terminal
Subnet Mask
Default Gateway
Screen 15: System Menu> 7. Net Menu> 1. Information
Without a screen, this is not available on the 5000 terminals.
43
Configuring 5000/5100:
System Menu
Net Menu > IP Setting
Set network parameters:
DHCP:
SubNet Mask:
Local IP Address:
Default Gateway:
DNS Server:
Local Name:
Domain Name:
Options – Enable or Disable
Enter a new Mask IP, if necessary.
Enter a new address for the terminal, if necessary.
Enter a new address for the default Gateway, if necessary.
Enter a new address for the DNS server, if necessary.
Enter a name for identifying the terminal.
The domain name of the host is shown here.
All of the setting could be obtained form DHCP server if DHCP is activated
44
Configuring 5000/5100:
System Menu
Screen 16: System Menu> 7. Net Menu> 2. IP Setting
45
Configuring 5000/5100:
System Menu
Net Menu > Echo Tests
Echo tests are used for verify connectivity. Press [ESC] to stop and exit the test.
You also need a test utility on PC to test the networking.
Screen 17: System Menu> 7. Net Menu> 3. Echo Tests
46
Configuring 5000/5100:
System Menu
Client Mode:
Set the terminal as a client.
Enter the IP address of a server that connection is desired.
Followed by an attempt to make connection with the access point.
Server Mode: Set the terminal as a server.
Followed by an attempt to make connection with the access point.
Screen 18: System Menu> 7. Net Menu> 3. Echo Tests: Client Mode
47
Configuring 5000/5100:
System Menu
Net Menu > Download via TCP/IP
If an Ethernet card is installed, the terminal can download new application program or
program update via TCP/IP.
You also need a downloading utility on PC to download program through network.
Results
Success: the new program will be activated right after downloading.
Failure: the terminal will resume to the current application program
Screen 19: System Menu> 7. Net Menu> 4. Download via TCP/IP
48
Configuring 5000/5100:
Program Manager
4.4 Program Manager
The 5000/5100 terminals support multiple applications and languages. In the menu of
Program Manager, it can download up to seven programs and one of them is made
active.
Warning! The Program Manager menu is NOT for the use of any end users.
How to access the Program Manager?
1.
2.
3.
4.
5.
Lift the upper enclosure by unscrewing the two screws on top of the terminal.
Disconnect BOTH the line power and main battery.
Re-connect the main battery and simultaneously press [5] + [8] from the keyboard.
The Program Manager menu is displayed on the LCD screen as shown below.
Re-connect the line power when configuration is done.
Figure 25: Program Manager menu
Program Manager Menu, which is generated by 51pm.shx, is unavailable by default.
Please download 51pm.shx in the System Manu first.
49
Configuring 5000/5100:
Program Manager
4.4.1 Download
Screen 20: Program Manager> 1. Download
Multiple programs as well as custom font file can be downloaded through RS-232
interface. There is a full list of programs and font file that are currently stored in the
terminal as follows.
01 ~ 06
File Name
Volume
Press [1 ~ 6] + [Enter]
ACT
File Name
Volume
[7] + [Enter]
or
[F6] + [F2]
Table 20: Listing of multiple programs and font
The terminal can store up to seven programs (including the one in active memory)
and one font file (may not be shown in this list).
Spare application programs (max. 6):
baud rate selectable
Active application program (1):
default baud rate 115200, none, 8, 1
Font file (1):
default baud rate 115200, none, 8, 1
A slot number followed by “c”: the program is written by C language.
A slot number followed by “f”: this is a font file.
50
Configuring 5000/5100:
Program Manager
Spare application programs
Empty slot:
1.
2.
3.
4.
Select an empty slot by pressing the corresponding number and then [Enter].
Select baud rate for downloading. Set matching parameters at PC end.
Connect cable and wait connecting…
To abort the action, press [ESC]. Then press [ESC] again to return to the menu.
Occupied slot:
If no available slots, you’ll have to replace one program with the new one.
1. Select a program that you want to delete by pressing the corresponding number
and then [Enter].
2. The program information is displayed on the screen. Press [Alpha] to enter the
capital mode. Then press [C].
3. Select baud rate for downloading. Set matching parameters at PC end.
4. Connect cable and wait connecting…
5. To abort the action, press [ESC]. Then press [ESC] again to return to the menu.
From the menu, you’ll find the program is deleted but no new program is present.
If you simply want to delete a program, press [D] in step 2.
Table 21: Downloading spare programs
[C], [D]: press the keypad to produce C or D when in the capital mode A.
51
Configuring 5000/5100:
Program Manager
Active application program or font file
The active slot:
1. Select the active program (may be an empty slot) by pressing the corresponding
number (that is 7) and then [Enter].
2. Set matching parameters at PC end: 115200, none, 8, 1
3. Connect cable and wait connecting…
4. If the downloaded program is an application, it will replace the active program and
come into effect immediately.
5. If it is a font file, then the current active program is still in use.
Table 22: Downloading active program or font
No font file will replace the active application program.
The new font file may not be shown in the program list if all slots are taken by
application programs, but you can view font information under System Menu>
Settings> Font.
>> Also see Section 4.3.2 Settings
52
Configuring 5000/5100:
Program Manager
4.4.2 Activate
Screen 21: Program Manager> 2. Activate
The list shows the entire spare programs stored in the terminal. From the list, you can
select from 01 to 06 and activate one of them.
When an application program is activated, it will be copied to the active memory
and replace the old one.
The  screen instructs that “Press [ESC] to clear file”. It
means the file system in the SRAM will be cleared out when pressing [ESC]. Then
there will be no data (transactions, settings, etc.) stored in the terminal when the
new program comes into effect. To keep the data, simply press any other key.
When a font file is activated, it will replace the system font. The active application
program will remain intact.
53
Configuring 5000/5100:
Program Manager
4.4.3 Version
Here provides information about the version of Program Manager.
Without a screen, this is not available on the 5000 terminals.
54
Configuring 5000/5100:
Kernel Menu
4.5 Kernel Menu
The Kernel Menu resides in the innermost core of the system. It has the highest
security and is always protected by the system. When the application program is
corrupted and the System Menu fails, the Kernel Menu provides an access to fix the
system.
Warning! The Kernel Menu is NOT for the use of any end users.
How to access the Kernel Menu?
1. Lift the upper enclosure by unscrewing the two screws on top of the terminal.
2. Disconnect BOTH the line power and main battery.
3. Re-connect the main battery and simultaneously press [1] + [5] + [7] from the
keyboard.
4. The Kernel Menu is displayed on the LCD screen as shown below.
5. Re-connect the line power when configuration is done.
Figure 26: Kernel Menu
55
Configuring 5000/5100:
Kernel Menu
4.5.1 Information
The information provided here helps diagnose the system.
H/W:
S/N:
M/D:
KNL:
DEV:
Hardware version
A unique serial number for the device
Manufacturing date
Kernel version
Code for optional hardware configurations, i.e. 1700
Type of Reader Module
Type of LAN Module
0= none
1= EM
2= Mifare
0= none
7= Ethernet
Reserved
Table 23: Device code explained
Without a screen, this is not available on the 5000 terminals.
56
Reserved
Configuring 5000/5100:
Kernel Menu
4.5.2 Load Program
The terminal must be configured correctly for downloading either of the following:
Program update
New application program
Font file
1. Connect RS-232 cable.
2. Set communication parameters at PC end: 115200, none, 8, 1.
3. Enter Kernel Menu> Load Program.
The system is ready to download the program to the active slot.
Results
Success: the new program or font file will be activated right after downloading.
Failure: the terminal will resume to the current application program or font
57
Configuring 5000/5100:
Kernel Menu
4.5.3 Kernel Update
The Kernel might be changed for improving performance or other reasons, and an
update is necessary.
1. Connect cable.
2. Set communication parameters at PC end: 115200, none, 8, 1.
3. Enter Kernel Menu> Kernel Update.
The system is ready to update the Kernel firmware.
Only RS-232 interface is allowed.
4.5.4 Test & Calibrate
These tools are provided for manufacturing use. No user definition is allowed.
Burn-In Test
Calibrate RTC
Warning! This is NOT for the use of any end users.
58
5. MANAGING 5000/5100
Depending on the application program downloaded to the terminals, managing the
5000/5100 terminals at PC end can be very flexible and simple.
For details, please see relevant documents such as Programming Guide.
Figure 27: Remote management
59
Managing 5000/5100
5.1 For proprietary applications
For any preloaded application program (5100*.SHX), we provide several ways for
managing the terminal from PC end.
Management Utilities
This is application dependant. For example, Menjin.exe is developed for Access
Control application.
Commands
Sending commands serves as an alternative to manage the terminals.
OCX Support
Customized utilities can be developed in an efficient way.
5.2 For custom applications
For user-defined application programs, management software is to be developed by
your own system programmers.
Programming Support
For development of custom application software, proprietary BASIC or C complier is
available through licensing agreement, as well as libraries.
60
SPECIFICATIONS
Power
Line power:
12 V ± 5% DC at 1000 mA
Backup battery:
Rechargeable 3.0 V, 7 mAh Lithium button cell
CPU
16-bit CPU:
Tunable clock, up to 22 MHz
Memory
Flash:
2 MB program memory
SRAM:
Standard 256 KB on-board data memory
Memory card (optional)
Programming Support
Components:
OCX
Compilers:
BASIC and C
Environment
Humidity:
Operating: 20% to 90% non-condensing
Storage: 10% to 95% non-condensing
Temperature:
Operating: 0 to 45 °C
Storage: -20 to 60 °C
EMC certified
FCC
Class B
61
Specifications
Enclosure
Material & Color:
ABS plastic
Black
Dimensions:
150 mm (L) x 150 mm (W) x 50 mm (H)
Weight:
Approx. 1.6 Kg (including one battery pack)
Input Devices
Reader:
Built-in RFID reader EM type
Keyboard:
21 keys rubber including 6 function keys, backlit, programmable
One external Mini Din connector provided by keyboard module
Display
Graphic LCD:
128 x 64 pixels, LED backlit, programmable –
4 lines by 8 characters for Chinese characters
Indicators
LED:
4 LEDs, programmable
Buzzer:
Low power transducer type, 1 KHz to 4 KHz, programmable
Interfaces
RJ-45 port:
62
Ethernet networking (optional)
TROUBLESHOOTING
The terminal cannot accept valid cards…
Regarding power –
Check if the power adaptor is plugged into a wall outlet.
Check if the outlet is working.
If the problem persists, check if the wiring inside the terminal is correct and secured.
Regarding memory –
Check if memory buffer is full. Then clean buffer by downloading data to a computer.
Regarding the reader –
Check if the selected reader type in your application matches the default setting.
>> Also see Section 4.3.1 Information: DEV
Check if the reader is working.
>> Also see Section 4.3.3 Tests: RFID
If the problem persists, re-connect the power and perform test.
The terminal cannot transmit or receive data to and from a host…
For Ethernet networking –
Check if the Ethernet cable is secured at both ends.
Check if parameters are correct.
>> Also see Section 4.3.7 NET Menu
63
Troubleshooting
The keyboard input seems not working properly…
Test keyboard.
>> Also see Section 4.3.3 Tests: Keyboard
If the problem persists, re-connect the power and perform test.
The external devices controlled by DI/DO signals are not working properly…
Check if the device is properly wired to the terminal blocks.
If the problem persists, re-connect the power and perform test.
About abnormal response…
The LEDs or LCD seem not working properly –
Test components.
>> Also see Section 4.3.3 Tests: LCD & LED
If the problem persists, re-connect the power and perform test.
The buzzer seems not working properly –
Test audible indicators.
>> Also see Section 4.3.3 Tests: Buzzer
If the problem persists, re-connect the power and perform test.
The terminal seems not working properly –
First upload all data to a computer, and then test memory.
>> Also see Section 4.3.3 Tests: Memory
If the problem persists, re-connect the power and perform test.
64
APPENDIX I – MOUNTING TEMPLATE
This mounting template is provided in actual size (1:1 scale).
1. Place this paper on the place you desire to mount the terminal.
2. Use paper tape to attach it on the surface.
3. Then use a power drill to drill holes on the four corners.
The size of these holes is 6mm in diameter and 21mm in depth.
Make sure that your printout doesn’t zoom in/out during printing.
Figure 28: Mounting template
65

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
About                           : uuid:97c20684-809b-468b-86dd-e21bd7de9458
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Create Date                     : 2005:10:05 03:53:52Z
Modify Date                     : 2005:10:14 22:25:50+08:00
Metadata Date                   : 2005:10:14 22:25:50+08:00
Document ID                     : uuid:00d0b708-0cc1-4089-b9d0-807ba9bba002
Instance ID                     : uuid:d6889d5e-d3f4-4a91-b03d-778fb6e73dd3
Format                          : application/pdf
Has XFA                         : No
Page Count                      : 78
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Q3N-ID-20