Cisco Systems BTS-TP1 Ripwave TTA Base Station User Manual ttaicguide

Cisco Systems, Inc Ripwave TTA Base Station ttaicguide

Contents

User Manual Section 1

Download: Cisco Systems BTS-TP1 Ripwave TTA Base Station User Manual ttaicguide
Mirror Download [FCC.gov]Cisco Systems BTS-TP1 Ripwave TTA Base Station User Manual ttaicguide
Document ID369728
Application IDNM0xcQUmYe7eD6RxmYPqEA==
Document DescriptionUser Manual Section 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize253.25kB (3165684 bits)
Date Submitted2003-10-30 00:00:00
Date Available2004-01-27 00:00:00
Creation Date2003-10-29 09:26:03
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2003-10-29 09:26:43
Document TitleMicrosoft Word - ttaicguide.doc
Document CreatorPscript.dll Version 5.0
Document Author: BBoyea

Ripwave Base Station
™
Installation & Commissioning Guide
Part Number 40-00047-00
Revision D, Version 1.0
February 28, 2003
Proprietary
All information disclosed by this document is the proprietary property of Navini Networks, Inc. and is protected by
copyright, trademark, and/or trade secret laws. All rights therein are expressly reserved.
Ripwave Base Station I&C Guide
Navini Networks, Inc.
About This Document
Purpose
This document provides a Navini-certified Installation & Commissioning Technician with
instructions to properly install the Base Transceiver Station, Radio Frequency Subsystem, and
cabling; and to test and commission the Base Station after installation.
Revision History
Date
2001
Revision/Version
A/1.0
Editors
N/A
Comments
Draft
B/v1.0
C/1.0
C/1.0
C/1.0
C/1.0
D/1.0
Authors
J. Price
C. Keltner
A. Chua
P. Blain
J. Coulson
D. Karina
K. Sharp
L. Hoffman
Same
Same
Same
Same
Same
Same
4.02
8.30.02
9.3.02
9.27.02
10.18.02
2.7.03
N/A
N/A
S. Redfoot
Same
Same
Same
D/1.0
Same
Same
Preliminary
Prepare for release 1.16
Review comments from class 8.30.02
Preliminary Commercial Release 1.18
Feedback on forms and specifications
Combined all Base Station I&C into one
manual; Preliminary 1.19
Standard Release 1.19
2.28.03
Contacts
Contact Navini Networks Technical Support during normal business hours: Monday through
Friday 8:30 a.m. to 5:30 p.m. Central Time. You can also submit questions or comments by web
or email at any time.
Corporate Headquarters:
Technical Support:
Web Address:
E-mail:
(972) 852-4200
1-866-RIPWAVE
www.navini.com / select Technical Support
techsupport@navini.com
Navini Networks, Inc.
2240 Campbell Creek Blvd.
Suite 110
Richardson, Texas 75082
USA
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Permissions, Trademarks & Distribution
Copyright© February 2003, Navini Networks, Inc. All information contained herein and
disclosed by this document is the proprietary property of Navini Networks, Inc. and all rights
therein are expressly reserved. Acceptance of this material signifies agreement by the recipient
that the information contained in this document is confidential and that it will be used solely for
the purposes set forth herein. Acceptance of this material signifies agreement by the recipient
that it will not be used, reproduced in whole or in part, disclosed, distributed, or conveyed to
others in any manner or by any means – graphic, electronic, or mechanical, including
photocopying, recording, taping, or information storage and retrieval systems – without the
express written permission of Navini Networks, Inc.
Navini Networks, Internet at the Speed of Thought, zero-install, unwired by Navini, the Navini
Networks logo, and Ripwave are trademarks of Navini Networks, Inc. Other product and
company names mentioned herein may be trademarks and/or service marks of their respective
owners.
Nothing herein constitutes any representation, warranty, assurance, or guaranty of any
kind.
Because of continuing developments and improvements in design, manufacturing, and
deployment, material in this document is subject to change without notification and does not
represent any commitment or obligation on the part of Navini Networks, Inc.
Navini Networks, Inc. shall have no liability for any error or damages resulting from the use of
this document. Any unauthorized usage is strictly prohibited without the express written
permission of Navini Networks, Inc.
 2003 Navini Networks, Inc. All rights reserved.
Navini Networks, Inc.
2240 Campbell Creek Boulevard
Suite 110
Richardson, Texas 75082
USA
Part #40-00047-00 Rev D v1.0
February 28, 2003
Ripwave Base Station I&C Guide
Navini Networks, Inc.
TABLE OF CONTENTS
ABOUT THIS DOCUMENT .............................................................................................................. 2
PERMISSIONS, TRADEMARKS & DISTRIBUTION ............................................................................ 3
SAFETY ........................................................................................................................................ 6
REGULATORY INFORMATION........................................................................................................ 8
BATTERY CAUTION & PROCEDURES ............................................................................................ 9
GLOSSARY OF TERMS & ABBREVIATIONS .................................................................................. 10
CHAPTER 1: OVERVIEW ...................................................................................................... 17
RIPWAVE DESCRIPTION .............................................................................................................. 17
PROCEDURAL DOCUMENTS & FORMS ........................................................................................ 18
I&C PROCESS FLOWCHART........................................................................................................ 19
BASE STATION COMPONENTS..................................................................................................... 29
GENERAL SPECIFICATIONS ......................................................................................................... 33
BASE STATION SPECIFICATIONS ................................................................................................. 34
MATERIALS SPECIFICATIONS...................................................................................................... 36
CHAPTER 2: INSTALLATION .............................................................................................. 39
PRE-INSTALLATION .................................................................................................................... 39
INSTALL POWER & GROUNDING ................................................................................................ 42
INSTALL CABLES ........................................................................................................................ 45
INSTALL THE BTS ...................................................................................................................... 50
INSTALL GPS ANTENNAS........................................................................................................... 55
INSTALL THE RFS....................................................................................................................... 58
VERIFY INSTALLED CIRCUIT CARDS .......................................................................................... 69
BASE STATION INSTALLATION CERTIFICATION .......................................................................... 70
CHAPTER 3: COMMISSIONING .......................................................................................... 71
REVIEW CUSTOMER NETWORK PLANS ....................................................................................... 71
INSTALL EMS SERVER ............................................................................................................... 71
VERIFY CABLE CONNECTIONS ................................................................................................... 72
CONFIGURE & POWER UP THE BTS ........................................................................................... 73
CALIBRATE THE BASE STATION ................................................................................................. 96
VERIFY THE CALIBRATION ....................................................................................................... 100
EXPORT BTS DATA.................................................................................................................. 110
PERFORM LOCAL CPE TESTS ................................................................................................... 111
INSTALL & TEST CUSTOMER EMS OPERATIONS ..................................................................... 116
PERFORM CALIBRATION USING CUSTOMER’S EMS ................................................................. 116
VERIFY SYSTEM PERFORMANCE .............................................................................................. 117
VERIFY SYSTEM OPERATION WITH MULTIPLE CPE’S ............................................................. 118
BACK UP EMS DATABASE....................................................................................................... 118
CUSTOMER ACCEPTANCE ......................................................................................................... 118
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
APPENDIX A: ORDERING DOCUMENTATION & FORMS ......................................... 119
APPENDIX B: SITE CANDIDATE EVALUATION FORM.............................................. 121
APPENDIX C: RFS SYSTEM TEST (CABLE SWEEPS) .................................................. 133
APPENDIX D: BASE STATION INSTALLATION CERTIFICATION .......................... 151
APPENDIX E: CONFIGURATION FORMS....................................................................... 154
APPENDIX F: BASE STATION CALIBRATION VERIFICATION* ............................. 175
APPENDIX G: DRIVE STUDY ............................................................................................. 183
APPENDIX H: LOCATION (FTP) TESTS .......................................................................... 188
APPENDIX I: CUSTOMER ACCEPTANCE ...................................................................... 195
APPENDIX J: OUTDOOR ENCLOSURES ......................................................................... 197
APPENDIX K: INSTALL CONNECTORS ON CABLES .................................................. 213
APPENDIX L: CHASSIS ALARMS...................................................................................... 215
APPENDIX M: ANTENNA DRAWINGS............................................................................. 217
APPENDIX N: RECTIFIER/BBU SPECIFICATIONS ...................................................... 219
APPENDIX O: SAMPLE BILL OF MATERIALS (BOM)................................................. 227
APPENDIX P: SAMPLE BASE STATION DRAWING ..................................................... 231
APPENDIX Q: SAMPLE STATEMENT OF WORK ......................................................... 233
APPENDIX R: SAMPLE RESPONSIBILITY ASSIGNMENT MATRIX (RAM)........... 237
LIST OF EXHIBITS................................................................................................................. 245
LIST OF FIGURES .................................................................................................................. 247
LIST OF TABLES .................................................................................................................... 249
Part #40-00047-00 Rev D v1.0
February 28, 2003
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Safety
To optimize safety and expedite installation and service, read this document thoroughly. Follow
all warnings, cautions, and instructions marked on the equipment and included in this document.
To aid in the prevention of injury and damage to property, cautionary symbols have been placed
in this document to alert the reader to known potentially hazardous situations, or hazards to
equipment or procedures. The symbols are placed before the information to which they apply.
However, any situation that involves heavy equipment and electricity can become hazardous, and
caution and safety should be practiced at all times when installing, servicing, or operating the
equipment.
Caution Symbol - possible equipment or property damage
Warning Symbol - could cause personal injury or otherwise be hazardous to
your health
Navini Networks, Inc., expressly requires that when using Navini electronic equipment always
follow the basic safety precautions to reduce the risk of electrical shock, fire, and injury to
people and/or property.
1. Follow all warnings and instructions that come with the equipment.
2. Do not use the equipment while you are in a bathtub, shower, pool, or spa. Exposure of the
equipment to water could cause severe electrical shock or serious damage to the equipment.
3. Do not allow any type of liquid to come in contact with the equipment. Unplug the
equipment from the power source before cleaning. Use a damp cloth for cleaning. Do not use
any soaps or liquid cleaners.
4. Follow all airport and FAA regulations when using the equipment on or near aircraft.
5. Only operate the equipment from the type of power source(s) indicated in this manual (110
VAC or Navini supplied battery). Any other type of input power source may cause damage to
the equipment.
6. Power the equipment using only the battery or the AC adapter cable provided, and in
accordance with the instructions specified in the User Guide.
7. Do not use a frayed or damaged power cord. Do not place the power cord where it can be
stepped on or tripped over.
8. Do not touch wires where the insulation is frayed or worn unless the equipment has been
disconnected from its power source.
9. Do not overload wall outlets, power strips, or extension cords. This can cause serious
electrical shock or fire.
10. Do not place the equipment on an unstable surface. It can fall and cause injury or damage to
the equipment.
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
11. Do not disassemble the equipment. Removing covers exposes dangerous voltages or other
risks and also voids the warranty. Incorrect reassembly can cause equipment damage or
electrical shock. Only an authorized repair technician should service this product.
12. Do not expose the equipment to extreme hot or cold temperatures.
13. Do not use the equipment under the following conditions:
• When the equipment has been exposed to water or moisture.
• When the equipment has been damaged.
• When the power cord is damaged or frayed.
• When the equipment does not operate properly or shows a distinct
change in performance.
Part #40-00047-00 Rev D v1.0
February 28, 2003
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Regulatory Information
FCC Notice
WARNING! This device is a Radio Frequency transmitter. It is required to comply with
FCC RF exposure requirements for transmitting devices. A minimum separation distance
of 8 inches (20 cm) or more must be maintained between the antenna and all persons
during device operations to ensure compliance with the FCC’s rules for Radio Frequency
Exposure. If this minimum distance cannot be maintained, exposure to RF levels that
exceed the FCC’s limits may result.
FCC Compliance and Advisory Statement
Tested To Comply
With FCC Standards
FOR HOME OR OFFICE USE
This equipment has been tested and found to comply with the limits for a class B digital
device, Pursuant to Part 15 of the FCC rules. The operation is subject to the following
two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may
cause undesired operation.
These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed or used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
(1) Reorient or relocate the receiving antenna;
(2) Increase the separation between the equipment and the receiver;
(3) Connect the equipment to an outlet on a circuit different from that to which the
receiver is connected;
(4) Consult the dealer or an experienced radio/TV technician for additional suggestions.
INFORMATION TO USER
This device has been authorized as a radio frequency transmitter under the appropriate
rules of the Federal Communications Commission. Any changes or modifications not
expressly approved by Navini Networks could void the user’s authority to operate the
equipment.
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Battery Caution & Procedures
WARNING! To reduce risk of injury or fire, follow these instructions when handling the
battery.
1. Risk of explosion is possible if the battery is replaced with one not supplied by Navini
Networks.
2. Do not dispose of the battery in a fire. It may explode. Check with the local codes for
battery disposal guidelines.
3. Do not open or mutilate the battery. The battery contains substances that are toxic,
corrosive, or harmful to humans. If battery substances come in contact with the skin,
seek medical help immediately.
4. Do not attempt to recharge the battery by any means except per the instructions in this
manual.
5. Remove the battery from the equipment if the equipment is not going to be used for a
long period of time. The battery could leak and cause damage to the equipment.
6. Exercise care when handling the battery to prevent shorting the battery with conducting
materials such as bracelets, rings, and keys.
7. Store the battery pack in a dry place, 0 to +40 degrees Celsius.
8. Dispose of used batteries according to environmental guidelines.
Part #40-00047-00 Rev D v1.0
February 28, 2003
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Glossary of Terms & Abbreviations
Term
802.11
Stands For....
802.11 Standard
ACC
ACK
Access Channel or
Access Code Channel
Acknowledge
AP
Access Point
ARP
Address Resolution Protocol
ASYNCH
Asynchronous
ATM
Asynchronous Transfer Mode
BB
BCC
BS
Broadband
Broadcast Code (or Control)
Channel
Base Station
BTS
Base Transceiver Station
BW
Bandwidth
BYTE
CAM
Byte
Configuration & Alarm Manager
CC
10
Communications Controller or
Cross-check
Meaning
An IEEE LAN standard for wireless Ethernet replacement
technology in the ISM band. Runs at up to 10 Mbps.
AKA, Paging Channel. The signal path that tells a mobile to
prepare for an incoming call.
Positive message sent by a protocol to acknowledge reception
of a transmitted packet
Wireless LAN transceiver that acts as a center point of an allwireless network or as a connection point between wireless and
wired networks.
The function of the ARP is to match higher-level network IP
addresses with the physical hardware address of a piece of
equipment.
Not occurring at regular intervals, as in data piped over a
network
Transporting a broad range of user data at irregular intervals
over network facilities
RF system with constant data rate of 1.5 Mbps or higher.
A channel of data transmitted by one entity and received by
many devices.
Network Access equipment and software that transmits and
receives, as well as processes, voice or data calls from mobile
units to network connections. A Ripwave Base Station consists
of the Base Transceiver Station (BTS) and the Radio
Frequency Subsystem (RFS), or antenna, plus a Global
Positioning System (GPS) antenna for timing.
The Ripwave BTS is a two-shelf rack that holds the RF
modules and digital circuit cards that interpret radio signals
into computer language and sends messages to and from the
local or wide area network. It functions between the RFS and
the EMS to handle the signaling.
Frequency spectrum usable for data transfers. It describes the
maximum data rate that a signal can attain on the medium
without encountering significant loss of power. Usually
expressed in bits per second (digital) or Hertz (analog).
8 bits
An EMS functionality that is handled through a Graphical User
Interface for purposes of configuring elements in the system
and handling other OAM requirements.
A type of circuit card that resides in the Digital shelf of the
Ripwave BTS. It handles all interfaces between BTS and
network. 2An EMS functionality that allows the system to
perform an automated sanity check of the datafill.
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Term
CD
CDMA
CD-ROM
CHP
CLEC
CLI
CORBA
CPE
dB
dBd
dBi
DHCP
DiffServ
DIR
DL
DNS
DS-1
DSL
Ripwave Base Station I&C Guide
Stands For....
Meaning
Compact Disk or 2Change Directory 1An optical disk capable of storing large amounts of data (700x
floppy disk). It can be inserted into most pc’s and “read” to
load files onto a computer 2A software programming term in
“C” language that tells the computer to go to a different
location in the computer’s memory.
Code Division Multiple Access
Digital cellular technology that uses a spread-spectrum
technique where individual conversations are encoded with a
random digital sequence. Increases capacity and speed of
communications messages between mobile units over other
types of wireless networks.
Compact Disk - Read Only Memory See “CD.” If a CD is not Read Only, computers can write data
to it with that capability.
Channel Processor Card
A card in the digital shelf of the BTS that performs the first
stage of signal processing for up to 4 antennae. One Navini 2.4
GHz BTS has 8 antennae. The card performs digital-to-analog
conversion (DAC) and analog-to-digital conversion (ADC) for
up to 10 carriers.
Competitive Local Exchange Carrier A telephone company that competes with an incumbent Local
Exchange Carrier (LEC).
Command Line Interface
A text-based programming language through which a user
communicates with an operating system or an application.
Common Object Request Broker
A standard for Network Management Systems that allows
Agent
integration with NMS regardless of programming language or
Operating System.
Customer Premise Equipment
Communications equipment that resides at the customer’s
location.
Decibel
Unit of measurement for sound.
Decibel/Dipole
A ratio, measured in decibels, of the effective gain of an
antenna compared to a dipole antenna (2 horizontal rods in line
with each other). The greater the dBd value the higher the gain
and therefore the more acute the angle of coverage.
Decibel/Isotropic
A ratio, measured in decibels, of the effective gain of an
antenna compared to an isotropic antenna (measured along
axes in all directions). The greater the dBi value the higher the
gain and therefore the more acute the angle of coverage.
Dynamic Host Configuration
A protocol for dynamically assigning IP addresses to devices
Protocol
on a network.
Differentiated Service
Different Quality of Service (QoS) descriptions for different
types of traffic, i.e., voice, video, email. The DiffServ table is
where each level of QoS is defined. Equivalent to Class of
Service (COS) in POTS.
Directory
A special kind of file used to organize other files into a
hierarchical structure.
DownLink
In this case, data messages transmitted from the BTS to the
CPE.
Domain Name Server
TCP/IP networking term that is a protocol for matching objects
to network (IP) addresses.
Digital Signal - 1
Also “T1” or “E1”. Digital transmission equipment that can
handle up to 1.544 Mbps.
Digital Subscriber Line
A type of service whereby users gain access to the Internet
through high-speed data networks.
Part #40-00047-00 Rev D v1.0
February 28, 2003
11
Ripwave Base Station I&C Guide
Term
DSP
Stands For....
Digital Signal Processor
EID
Equipment Identifier
EMS
Element Management System
ERP
Effective Radiated Power
FCC
Federal Communications
Commission
FE
Far End
FTP
File Transfer Protocol
Gain
Gain
Gb
GB
GHz
Gigabit
Gigabyte
Gigahertz
GPS
Global Positioning System
GUI
Graphical User Interface
HW
Hz
I&C
Hardware
Hertz
Installation & Commissioning
IEC
Inter-exchange Carrier
IF
Interface Card
IMA
Inverse Multiplexing over ATM
IP
Internet Protocol
ISP
Kb
KB
KHz
Internet Service Provider
Kilobit
Kilobyte
Kilohertz
12
Navini Networks, Inc.
Meaning
Compressing or manipulating analog signals to digital signals
and vice-versa.
Field in EMS for assigning IP address or name to individual
pieces of equipment for purposes of configuring the system.
An application that allows the user to define and manipulate
managed objects as a system within an overall network.
The actual power in Watts radiated from a transmitter’s
antenna.
United States government regulatory agency that supervises,
licenses and otherwise controls electronic and electromagnetic
transmission standards.
A relative term that refers to the receiving element in a
network, as opposed to the near-end element that is
transmitting data.
A TCP/IP method consisting of a client and server and used to
transfer files between two or more sites or elements in a
network.
Ratio of the output amplitude of a signal to the input amplitude
of a signal, expressed in decibels (dB).
One billion (1,000,000,000) bits.
One billion (1,000,000,000) bytes.
One billion (1,000,000,000) hertz - cycles per second. Ultra
high frequency (UHF) signals, including microwave signals.
A constellation of 24 well-spaced satellites that orbit the earth
and enable users with GPS antennas to pinpoint their exact
geographical position.
A graphic rather than purely text based user interface to a
computer or computing system.
Physical, tangible equipment
1 cycle per second.
Term used to describe the procedures of physically installing
technical equipment then powering up the equipment to make
sure it will operate (to put it “into commission”).
Also IXC. Public switching network service provider (carrier)
that connects across and between local exchange carriers
(LEC).
Card on the digital shelf of the Ripwave BTS that takes the
analog signal from the Channel Processor card (CHP) and
converts it to a baseband signal before sending it on to the RF
modules for transmission (forward link), and vice-versa
(reverse link).
A method of building dynamic routes of 2 or more T1’s to
increase bandwidth so that PVC’s can share the IMA
resources, as needed, for data transmissions.
A TCP/IP protocol used to route data from its source to its
destination.
A company that provides access to the Internet.
1,024 bits
1,024 bytes
1,000 hertz.
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Term
L1
Stands For....
Layer 1
L2
Layer 2
L3
Layer 3
LAN
Local Area Network
LCP
Link Control Protocol
LED
Light-emitting Diode
LLC
Logical Link Controller
LOS
Line-of-sight
MAC
Media Access Control
Mb
MB
Mbps
MDM
Megabit
Megabyte
Megabits Per Second
Modem Card
MHz
Megahertz
MIB
Management Information Base
MMDS
NE
Multipoint Multi-channel
Distribution Service
Near-end or 2Network Element
NLOS
Non Line-of-site
Part #40-00047-00 Rev D v1.0
February 28, 2003
Ripwave Base Station I&C Guide
Meaning
Physical Layer. Part of the OSI rules and standards for network
management. L1 describes the physical layer, or electrical and
mechanical port-to-port connections, in the network.
Data Link Layer. Part of the OSI rules and standards for network
management. L2 describes the data link layer where data is set up
and torn down in a specific format (frames), through the overall
network. Also responsible for detecting and correcting errors by
requesting retransmission.
Network Layer. Part of the OSI rules and standards for network
management. L3 describes the network addressing that gets data
to its destination within the network, i.e., IP addressing.
A data network of interconnected computers, servers, printers,
and other peripherals that communicate at high speeds over short
distances, usually within the same building. Also allows for
sharing of resources.
Basis of the Point-to-Point Protocol (PPP) scheme for negotiating
and establishing connections.
An electronic device that lights up when electricity passes
through it. Often used to indicate equipment or system state.
A protocol that governs the transition of frames between data
stations regardless of how the medium is shared. It’s the upper
sub-layer that further defines the Media Access Control (MAC)
protocol. It provides the basis for an unacknowledged
connectionless service on a LAN - i.e., error correction,
multiplexing, broadcasting.
Describes laser, microwave, RF, and infrared transmission
systems that require no obstruction in a direct path between the
transmitter and the receiver.
Protocol that governs access to a network in order to transmit
data between nodes. In a wireless LAN, the MAC is the radio
controller protocol (L2).
One million (1,000,000) bits.
One million bytes. Literally - 1,048,576 bytes.
Transmission speed at rate of one million bytes per second.
A card in the Navini BTS that converts digital signals into analog
so the signals can be transmitted over telephone lines, and viceversa. Modem stands for modulator/demodulator.
One million (1,000,000) hertz - cycles per second. Normally used
to refer to how fast a microprocessor can execute instructions.
A collection of managed objects used in SNMP-based networks.
MIB’s carry information in a standard format so external tools
can analyze network management and performance.
Fixed wireless, high-speed local service that operates at 2.1 - 2.7
GHz. Speed 10 Mbps. Originally conceived for cable TV service.
The transmitting end, versus the receiving end, of a signal
transmission. 2 A router, switch, or hub in an ISDN network.
Describes laser, microwave, RF, and infrared transmission
systems that can penetrate obstructions in the path between the
transmitter and the receiver.
13
Ripwave Base Station I&C Guide
Term
NMS
NOC
OAM
OS
OSI
PC
PCB
PDU
Ping
PPPoE
Propagation
PSK
PSN
PSTN
QAM
QoS
14
Navini Networks, Inc.
Stands For....
Network Management System
Meaning
A product that helps manage a network generally hosted on a
well-equipped computer such as an engineering workstation. The
system tracks network statistics and resources.
Network Operations Center
A centralized point, much like a traffic control tower, where
technicians or engineers can monitor network activity, alarms,
and statistics, as well as make network configuration and other
changes dynamically. For Internet, the NOC is often a hub for
ISP services.
Operation, Administration,
A set of network management functions. Also describes the
Maintenance
human-machine interface tasks - i.e., to operate the system, to
administer the system, and to maintain the system.
Operating System
A software program that manages the basic operation of a
computer. Most Operating Systems are either based on
Open Systems Interconnection
An ISO model for worldwide communications that defines 7
layers of network protocol: L1 Physical Layer; L2 Data Link
Layer; L3 Network Layer; L4 Transport Layer; L5 Session
Layer; L6 Presentation Layer; L7 Application Layer.
Personal Computer
Any IBM-compatible computer, so named because IBM’s first
commercial end user computer was called a PC.
Printed Circuit Board
A hardware module that holds electronic circuitry and usually
fits into a larger frame where the various PCB’s are
interconnected electronically.
Packet Data Unit or Protocol Data A data packet. Refers to that which is exchanged between peerUnit
layer entities. Contains header, data, and trailer information.
Ping
Generalized term from sonar science, where a short sound burst
is sent out and an echo or “ping” is received. Used to determine
if signals or packets have been dropped, duplicated, or reordered.
Point-to-point Protocol Over
A protocol that allows dial-up Internet connections. Includes the
Ethernet
Link Control Protocol as well as Network Control Protocols.
Propagation
To spread out and affect a greater area; travel through space, as
in radio waves.
Phase Shift Keying
Digital transmission term that means an angle modulation where
the phase of the carrier varies in relation to a reference or former
phase. An encoded shift. Each change of phase carries one bit of
information, where the bit rate equals the modulation rate.
Packet Switched Network
A network in which data is transferred in units called packets.
Packets can be routed individually and reassembled to form a
complete message at the definition.
Public Switched Telephone
Typically used in the same context as POTS. Analogous to a
Network
network of major highways originally built by a single
organization but added to and expanded by multiple
organizations. AKA, backbone networks.
Quadrature Amplitude ModulationA bandwidth conservation process routinely used in modems.
Creates higher throughput but decreased coverage area.
Quality of Service
A guaranteed throughput for critical network applications, such
as Voice over IP. Term primarily used in an ATM environment.
Five classes of service: Class 1 Video; Class 2 Audio; Class 3
Data Connection.
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Term
RAM
RF
RFS
RSSI
Rx
S-CDMA
SMDS
SMS
SNMP
SNR
SO/HO
SSI
SW
SYN
SYNCH
TCC
TCP
TCP/IP
Ripwave Base Station I&C Guide
Stands For....
Random Access Memory
Radio Frequency
Meaning
Computer memory that can be accessed randomly.
A portion of the electromagnetic spectrum in the frequency
range between audio and infrared: 100 KHz to 20 GHz. RF
measurements are expressed in Hz (unit for measuring
frequency); MHz = 1 Million Hz; GHz = 1 Billing Hz.
Radio Frequency Subsystem
A term for the antenna portion of the base station.
Receiver Signal Strength Indicator A term that describes the measure of the signal strength in
kilohertz or gigahertz between the transmission and the receiving
end.
Receive
An abbreviated way of expressing the term, receive, as in to
receive a transmission.
Synchronous Code Division
Wireless technology based on data being transferred at a fixed
Multiple Access
rate using Code Division Multiple Access algorithms.
Switched Multi-megabit Data
Connectionless service for MAN/WAN based on 53-byte packets
Service
that target the interconnection of different LAN’s into a public
switched network at speeds higher than T1.
Short Message Service or
A protocol that allows mobile users to send text-based messages
from one device to another. The text appears on a device’s screen
Systems Management Server
and may be a maximum 160 characters in length. 2A Windows
NT process that allows a network administrator to inventory all
hardware and software on the network, then perform software
distribution over the LAN.
Simple Network Management
Standard management request-reply protocol for managing
Protocol
TCP/IP networks. A device is said to be SNMP compatible if it
can be monitored or controlled using SNMP messages.
Signal-to-noise Ratio
Related to RSSI, a measurement of the intended signal being
transmitted against the other entities that can interfere with the
signal.
Small Office/Home Office
Small, remote office with a MAN or WAN connection back to a
larger corporate network and/or the Internet.
Signal Strength Indicator
See “RSSI”.
Software
Computer instructions or data.
Synthesizer Card
A circuit card in the Navini BTS digital shelf that provides a
local oscillator and system clock with a single calibration
transceiver. The card is used to calibrate the Base Station so that
no external spectrum analyzer or signal generator is required.
Synchronous
Digital packets or signals that are sent at the same, precisely
clocked fixed rate of speed.
Traffic Channel or 2Transmission 1A portion of a radio channel used to enable transmission of one
Control Code
direction of a digitized voice conversation (as opposed to the
Voice Channel). 2A way of segregating traffic in order to define
controlled communities of interest among subscribers.
Transport Control Protocol
A standardized transport protocol between IP-based network
nodes that allows two hosts to establish a connection and
exchange streams of data. TCP operates on top of Internet
Protocols and handles the multiplexing of sessions, error
recovery, reliability and flow; it guarantees packets are delivered
in the same order in which they were sent.
Transport Control
A set of protocols that allows cooperating computers to share
Protocol/Internet Protocol
resources across the network. TCP provides the reliability in the
transmission, while IP provides connectionless packet service.
Part #40-00047-00 Rev D v1.0
February 28, 2003
15
Ripwave Base Station I&C Guide
Term
TDD
Stands For....
Time Division Duplex
TFFS
True Flash File System
TTL
Time-to-live
Tx
Transmit
UL
UpLink
USB
Universal Serial Bus
VCC
Virtual Channel Circuit
VCI
Virtual Channel Identifier
VCL
Vector
Virtual Channel Link
Vector
VPC
Virtual Private Channel
VP
Virtual Path
VPI
Virtual Path Identifier
VPL
Virtual Path Link
WAN
16
Wide Area Network or
Wireless Access Network
Navini Networks, Inc.
Meaning
A digital transmission method that combines signals from
multiple sources and allows a single channel to alternately carry
data in each direction of a link.
Memory in a computing device that does not lose its information
when powered off. Available as a SIMM or PCMCIA card, it
usually stores router Operating System (OS) software. Can be
easily updated.
A field in the Internet Protocol that specifies how many more
hops a packet can travel before being discarded or returned.
To send by wire or other medium electronically or through air
via electromagnetic waves to a receiving communications device.
Describes the direction of signal flow being sent from a
subscriber to a network system, as in from a mobile device (CPE)
to a base station.
An external bus standard for plug-and-play interfaces between a
computer and add-on devices, such as a mouse, modem,
keyboard, etc. One USB port can connect up to 127 devices.
AKA, Virtual Channel Connection or Virtual Circuit Connection.
A logical circuit made up of Virtual Channel Links, which carry
data between two end points in an ATM network.
A 16-bit value in the ATM cell header that provides a unique
identifier for the Virtual Channel that carries that particular cell.
A connection between two ATM devices.
A quantity representative of both magnitude and direction
(energy + orientation in space)
AKA, Virtual Path Connection. A grouping of Virtual Channel
Connectors, which share one or more contiguous VPL’s.
A set of Virtual Channels grouped together between cross-points
(i.e., switches).
An 8-bit value in the cell header that identifies the VP as well as
the VC to which the cell belongs. The VPI + VCI identify the
next destination of a cell as it passes through a series of ATM
switches.
A group of unidirectional VCL’s with the same end points in a
Virtual Path. Grouping VCL’s into VPL’s reduces the number of
connections to be managed. One or more VPL’s makes up a
VPC.
A communications network that spans geographically separate
areas and which provide long-haul services. Examples of internetworked connections are frame relay, SMDS, and X.25
protocols. 2 General term for any product primarily used to gain
access to the Internet, as opposed to being part of the actual
Internet devices or software.
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Chapter 1: Overview
Ripwave Description
A Ripwave system has three main components: the Customer Premise Equipment (CPE); the
Base Station; and the Element Management System (EMS). The Base Station performs the CPE
registration and call processing, and provides the interface between the backhaul network and the
EMS. It is made up of the Base Transceiver Station (BTS) and the Radio Frequency Subsystem
(RFS) (Figure 1). This manual provides the guidelines and instructions for installing and
commissioning (I&C) the Base Station.
Figure 1: Base Station Installation With Panel Antenna
LIGHTNING
ROD
ANTENNA
BRACK
ET
SELF SUPPORTING
GUIDE
PANEL
ANTENNA
Note: The illustration shows both
an outdoor and an indoor BTS,
but only one panel antenna. In
reality, each BTS requires
its own panel.
PSX-ME
GROUND PROTECTOR
RF CABLES
SURGE
ANTENNA TOWER
BAR
CABLE
HANGERS
GPS
SHELTER / HUT
CABLE
ENTRY
PSX
OPTION 2
GROUND BAR
OUTDOOR BTS
24VDC @ 60A
ETHERNET
TELCO
CABINET
GND
Part #40-00047-00 Rev D v1.0
February 28, 2003
CABLE
LADDER
GROUND
BAR
OPTION 1
INDOOR BTS
24VDC
@ 60A
ETHERNET
/ TELCO
CABINET
GND
OVERHEAD
CABLE LADDER
PSX
GROUND BAR
NAVINI
BTS
17
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Procedural Documents & Forms
You will refer to other Ripwave documents, procedures, and forms in the process of installing
and commissioning the Base Station. They are listed in Appendix A of this manual. The product
documentation is provided on the Ripwave Standard Documentation CD (Table 1). As well, the
EMS manuals can be viewed on-line through the EMS Server and Client applications.
Table 1: Ripwave Standard Documentation CD
Order Number 95-00116-00
EMS Overview Manual
EMS Software Installation
EMS Administration Guide
Ripwave Configuration Guide
EMS CLI Reference Manual
Ripwave Alarm Resolution Reference Manual
Ripwave Base Station Operations & Maintenance Guide
Ripwave RFS Configuration Quick Guide
EMS Diagnostic Tools Guide
Ripwave Modem Quick Installation Guide
English
Spanish
Ripwave Modem User Guide
English
Spanish
Ripwave Modem Software Update Tool Guide
Component or
Part Number
40-00016-03
40-00017-00
40-00031-00
40-00016-01
40-00016-02
40-00033-00
00-00046-00
40-00067-00
40-00032-00
40-00112-00
40-00098-00
40-00096-00
40-00111-00
40-00097-00
40-00099-00
40-00066-00
Format
MSWord/.pdf
MS Word/.pdf
MS Word/.pdf
MS Word/.pdf
MS Word/.pdf
MS Word/.pdf
MS Word/.pdf
MS Word/.pdf
MS Word/.pdf
MS Word/.pdf
MS Word/.pdf
MS Word/.pdf
MS Word/.pdf
MS Word/.pdf
MS Word/.pdf
MS Word/.pdf
A separate CD specifically created for personnel involved with installation and commissioning
of the Ripwave system, called “VAR I&C Documentation”, may be ordered by authorized
business partners and customers. The CD includes detailed procedures and electronic forms that
are used during the I&C process. Table 2 contains a partial listing of the files on this CD, while
Appendix A provides the complete list. The I&C forms found on the CD are referenced
throughout this manual, and copies are included in the appendices.
Table 2: VAR I&C Documentation CD
Order Number 95-00017-00
RFS Omni & Panel Data Sheets
Site Candidate Evaluation Form
RFS System Test Form
Base Station Calibration Verification Form
Drive Study Survey Form
Location (FTP) Test Form
Customer Acceptance Form
BTS Outdoor Selection Guide
Rectifier/Battery Backup Specification
18
Part Number
44-00037/38-00
40-00091-00
40-00093-00
40-00059-00
40-00076-00
40-00077-00
40-00117-00
44-00035-00
44-00036-00
Format
Excel (includes drawings)
Excel Spreadsheet
Excel Spreadsheet
Excel Spreadsheet
Excel Spreadsheet
Excel Spreadsheet
MS Word Document
MS Word Document
MS Word Document
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
I&C Process Flowchart
To put the I&C activities in the context of overall system deployment, Figure 2 provides a ‘flow’
of the key activities that are performed prior to and during the installation and commissioning of
the Ripwave Base Station. Post-I&C, the system that has been installed and commissioned goes
through Acceptance Testing against the customer’s objectives for that site. Once customer signoff on the site is achieved, the customer becomes fully responsible for operating the system.
Different job holders may perform various portions of these activities and not necessarily all of
the activities. In fact, Marketing and Engineering personnel typically handle the earlier tasks,
while installation may be a stand-alone function. Commissioning may or may not be handled by
the same people who designed or installed the site. Regardless of who does them, these key
activities have to be accomplished for successful deployment:
•
•
•
•
Site Engineering
Installation
Commissioning
Acceptance Testing and sign-off
Prior to installation, Navini and the customer formulate a Project Plan and Responsibility
Assignment Matrix (RAM) to clarify who will do what to complete the I&C activities. If
requested by the customer, Navini may provide personnel, procedures, forms, and/or tools
required to install and commission the Base Station equipment. They may also provide special
commissioning software programs, computers, and any other special test equipment required.
As part of the I&C duties, all testing results are recorded and kept for the customer to review and
approve. These test results include the cable sweeps, the BTS Calibration Verification, RF
System Tests, Drive Study, Line-of-Sight (LOS) FTP tests, and Non-Line-of-Sight (NLOS) FTP
test results. The I&C Supervisor provides site tracking and weekly status reports. All of these
tasks can be negotiated with the customer.
If Navini Networks is hired by a customer to provide Installation & Commissioning Services,
involvement and some actual deliverables are still required by the customer. For example, the
customer will need to review or perhaps even explain their Site Design Specifications, approve
Logistics Plans, provide shipping information, approve the Network Architecture Plan, etc.
As part of a successful hand-off from Navini to the customer, it is usually necessary for Navini to
provide some product training to customer personnel who will support the Base Station operation
on-going. Customers may opt to take on a Train-the-Trainer program, in which case Navini
certifies the customer’s instructors who then provide staff training thereafter.
Part #40-00047-00 Rev D v1.0
February 28, 2003
19
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Figure 2: I&C Process Flowchart
Site Engineering
1-Complete Project Plan
for customer
2-Generate coverage
prediction map
3-Conduct site survey
& complete the Site
Candidate Evaluation Form.
Complete the Interference
Analysis/CPE Site Survey
Tool.
Appendix B:
Site Candidate
Evaluation Form
4-Acquire chosen customer
site information
5-Perform Network
Architecture design
6-Develop Bill of Materials
(BOM)
Sample BoM provided
in Appendix P
7-Acquire materials
8-Confirm customer
backhaul & EMS Server
Hardware & FTP Server
are installed & operational
End
Click here to link to Appendix B or to Appendix P.
20
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Figure 2: I&C Process Flowchart, cont’d.
Installation
1-From shipping containers received at
customer site, gather Manufacturing’s inventory
sheet & test data collected from the BTS & RFS
equipment shipped. Verify all equipment arrived,
the test data is available, & serial numbers match
paperwork. Keep as part of customer site records.
2-Install all system buss
bars & surge protectors
3-Install & sweep RF
cables. Record results on
RFS System Test Form.
Appendix C:
RFS System
Test Form
4-Install & sweep
GPS cables
5-Test & install
data/power cable
6- If required, install
BTS mounting rack
7-Install BTS chassis
8-Install & verify
BTS & RFS grounding
Click here to link to Appendix C.
Part #40-00047-00 Rev D v1.0
February 28, 2003
21
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Figure 2: I&C Process Flowchart, cont’d.
9-Install & verify DC
input power source to BTS
10-Install GPS antennas
11-Sweep the RFS. Record the results
and the RFS serial numbers on the RFS
System Test Form.
12-Install RFS & surge protectors.
Connect 9 RF cables & data/power
cable to the RFS.
13-Sweep installed RFS & cables to verify
connections & cable loss. Record results on
RFS System Test Form.
14-Verify digital cards & PA cards are
installed & seated properly.
15-Record serial numbers & version
numbers of digital & PA cards on the Base
Station Installation Certification Form.
16-If required in Responsibility Assignment
Matrix (RAM), test the backhaul to the
customer demarcation point.
Appendix D:
Base Station
Installation
Certification
Form
Click here to link to Appendix D.
22
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Figure 2: I&C Process Flowchart, cont’d.
17-Provide printed package of measured
results & equipment inventory to
customer on-site.
18-Go over results using forms &` get
customer sign-off on Installation using
Base Station Site Installation Form.
End
Part #40-00047-00 Rev D v1.0
February 28, 2003
23
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Figure 2: I&C Process Flowchart, cont’d.
Commissioning
1-Review customer network plans
(i.e., T1 vs. Ethernet)
2-Are you using
No 3a-Install & configure* the Test
the customer
EMS Server & Client. Connect
EMS Server
to the BTS.
Yes
3b-Install & configure* the
customer EMS Server &
Client. Connect to the BTS.
*Appendix E:
Configuration
Data Forms
4-Enter the RFS configuration
by running the RFS script that
shipped with the antenna eqpt.
5-Verify all cables are
connected
6-Power up BTS & reconfigure Boot
Line configuration data through the
serial port.
7-After BTS has been powered up
at least 15 minutes, perform
3 calibrations.
8-Pass
calibration
Yes
No
9a-Perform system
troubleshooting procedures.
Click here to link to Appendix E.
24
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Figure 2: I&C Process Flowchart, cont’d.
9b-Perform Base Station calibration
Verify and record measurements on the
Base Station Calibration Verification Form.
10-Pass
calibration
verification
No
11a-Perform system
troubleshooting procedures
Appendix F:
Base Station
Calibration
Verification
Form
Yes
11b-Perform local “wireline”
CPE test
12-Wireline
CPE test
pass
No
Yes
13-Perform local over-the-air
(OTA) CPE test
14-OTA
CPE test
pass
No
Yes
Click here to link to Appendix F.
Part #40-00047-00 Rev D v1.0
February 28, 2003
25
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Figure 2: I&C Process Flowchart, cont’d.
15-’Test’
EMS used
No
Yes
16-Install & configure the
customer EMS Server & Client.
Connect to the BTS.
17-Verify EMS Server
& BTS connectivity.
18-Perform calibration. Ensure
successful results 3 times.
26
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Figure 2: I&C Process Flowchart, cont’d.
*NOTE: Step 19 is performed
only if no RF plot is available.
19*-Validate that the GPS & constellation
debugger are installed & operational on
the Drive Study computer. Perform
preliminary Drive Study. Record results
on the Drive Study Form.
20-Perform preliminary LOS Location
(FTP) testing. Perform 3 uploads & 3
downloads at 3 locations. Record results on
the FTP Test Form.
Appendix G:
Drive Study
Form
Appendix H:
FTP Test
Form
21-Perform preliminary NLOS Location
(FTP) testing. Perform 3 uploads & 3
downloads at 3 locations. Record results on
the FTP Test Form.
22-Send all preliminary test results
to Navini Technical Support
for evaluation.
23-Results
adequate
No
24a-Adjust RF parameters &
troubleshoot. Go back to
Step 17, Perform calibration.
Yes
Click here to link to Appendix G.
Click here to link to Appendix H.
Part #40-00047-00 Rev D v1.0
February 28, 2003
27
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Figure 2: I&C Process Flowchart, cont’d.
24b-Perform full Drive Study, & record
results on the Drive Study Form.
This is used for tuning the model.
25-Perform full LOS Location
(FTP) testing. Record results.
26-Perform full NLOS Location
(FTP) testing. Record results.
27-Send test results to
Tech Support
28-Verify system operation with
multiple CPE devices.
29-Back up the EMS database
30-Gather all required documents &
forms to create a delivery package
for the customer sign-off & for the
Navini Technical Support database.
31-Participate in customer sign-off
of Customer Acceptance Form.
End
Appendix I:
Customer
Acceptance
Form
Click here to link to Appendix I.
28
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Base Station Components
Base Transceiver Station (BTS)
The BTS consists of the RF Power Amplifiers (PA’s), the digital circuit cards, the backplane,
and the mechanical enclosure or housing. It performs the signal processing and RF transmission
for the system. There are two types of chassis: Combo and Split. The Combo Chassis is used
primarily with 2.4 GHz systems. The Split Chasses is used for all other (2.3, 2.5, 2.6 GHz)
systems (Figure 3).
The chassis is compartmentalized into two sections - the RF shelf and the Digital shelf. The BTS
connects to the network using a 10/100 Base-T Ethernet connection or up to 8 T1 interfaces. Up
to three BTS assemblies can be installed per system, depending on the configuration.
Figure 3: BTS Chassis
Combo Chassis
Split Chassis
RF Shelf
(Power Amplifiers)
Digital Shelf
(Circuit Cards)
Part #40-00047-00 Rev D v1.0
February 28, 2003
29
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Radio Frequency Subsystem (RFS)
The Radio Frequency Subsystem (RFS) is mounted on a transmission tower or building rooftop.
It transmits and receives data to and from the Ripwave Customer Premise Equipment (CPE)
using a digital beamforming transmission technique. The RFS may be either a panel antenna or
an omni antenna (Figure 4).
An RFS panel transmits in a directional mode, covering a transmit angle of 120 degrees. The
antenna can be used as a single mode antenna, or it can be used in a group of two or three
sectored antennas, covering 240 and 360 degrees respectively. Each panel requires a BTS to
operate. For example, in a tri-sectored cell with 3 panels, you would need 3 BTS’s. The omni
antenna provides omni-directional coverage of 360 degrees.
An RFS panel or omni contains eight (8) antenna elements, cavity filters, and, optionally, low
noise amplifiers (LNA). For downtilt, the omni must be situated as it comes from the factory. A
panel’s downtilt can be adjusted at the site. The higher up the antenna is placed, the more
downtilt it typically required.
Figure 4: RFS
Panel (Front)
30
Panel (Back)
Omni
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Global Positioning System (GPS)
One or two Global Positioning System (GPS) antennas are used with each Base Station. A GPS
antenna works with a constellation of satellites that orbit the earth, and it provides the ability to
pinpoint geographical locations. The two types of GPS antennas that may be ordered with a
Ripwave Base Station are the VIC 100 and the Motorola Timing 2000 (Figure 5).
Figure 5: GPS Antennas
VIC 100 GPS
Motorola Timing
2000 GPS
Part #40-00047-00 Rev D v1.0
February 28, 2003
31
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Mounting Racks & Enclosures
The BTS can be installed indoors or outdoors in industry standard 19- or 23-inch racks. Rack
adapters are needed to mount the equipment in a standard 23-inch rack. For outdoor BTS’s, the
customer can supply any standard enclosure from a multitude of vendors. Appendix J offers
suggestions for outdoor BTS enclosures. Figure 6 shows 3 BTS’s installed indoors.
Figure 6: Indoor BTS
Data/Power Cable
32
Lightning Arrestors Across Top
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
General Specifications
Input Power
The BTS requires +21 to 28 VDC power supply rated at 60 amps. Installers are referred to
industry standards for power supply installations.
Humidity
The operating environment of the BTS must control relative humidity to 5% to 95% RH, noncondensing.
Heat Dissipation
The combo BTS chassis, under normal operating conditions, will dissipate a maximum of 1000
Watts or 3415 BTU’s. The split chassis will dissipate a maximum of 1500 watts.
Airflow
Fresh air intake for the BTS chassis is along the lower front vertical panel. Exhaust is out of the
upper rear of the chassis. The I&C crew must ensure there are no obstacles to airflow present in
these areas. Exhaust air from other equipment should not mix with the BTS fresh air intake.
Accessibility
The BTS is intended for installation and use only in a restricted access location.
Part #40-00047-00 Rev D v1.0
February 28, 2003
33
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Base Station Specifications
Current Ripwave operating frequencies include those shown in Table 3. Testing on other
frequencies is underway and soon will be commercially available.
Table 3: Operating Frequencies
Model
2.3 GHz
2.4 GHz
2.5 GHz
2.6 GHz
Frequency Range
2.305 GHz to 2.359 GHz
2.40 GHz - 2.473 GHz
2.50 GHz - 2.595 GHz
2.602 GHz – 2.637 GHz
Operating Band
WCS
ISM
MMDS/ITFS
MMDS/ITFS
Chassis
Split
Combo
Split
Split
The Ripwave Base Station can be in a combo chassis or split chassis system. The split chassis is
for MMDS bands only; it is not available for 2.4 GHz systems. The specifications for the combo
and split chassis are shown in Tables 4 and 5.
Table 4: Combo Chassis System (ISM Systems)
Antenna Downtilt:
Antenna Gain:
Antenna Options:
Backhaul Interfaces:
Bandwidth Allocation:
Baseband Modulation:
Beamforming Gain:
Configurations:
DC Power Consumption:
Duplex Format:
Mechanical Dimensions:
Multiple Access Schemes:
Operational Frequency Band:
Operational Temperature:
Polarization:
Power Control:
Regulatory:
Reliability/Availability:
RF Channel Bandwidth:
RF Output Power (per channel):
Sensitivity:
Serviceability:
Spreading Spectrum Scheme:
Storage Temperature:
System Features:
34
2 & 4 degree options for Omni-directional; Mechanical for 120 degree
Sectored
12dBi Omni-directional, 17 dBi for 120-degree Sectored
Omni-directional or 120-degree Sectored
10/100 BaseT Ethernet or ATM over T1; up to (8) T1’s with or without
IMA, long haul support
Dynamic
Uplink QAM4
18dB
Omni-directional or Sectored; Indoor or Outdoor
21VDC to 28VDC @ 40 amps; 1000 watts
Time Division Duplexing (TDD)
30’’x19’’x14’’ for indoor BTS (single cell/sector), 60“x15”diameter for
omni RFS antenna, 46”x23” sectored RFS antenna
Multi-carrier Beamforming Synchronized (MCBS) CDMA
See Table 3
0 to +50 degrees C (indoor); -40 to +50 degrees C (outdoor)
Vertical
Forward & reverse, open & closed loop
UL 1950, FCC part 15
Load-sharing
6MHz
5 watts max
-114 dBm/single channel (NF of 5dB)
Field replaceable cards, EMS remote reset
Direct Sequence Spreading (DSS)
-40 to +70 degrees C
Reed Soloman forward error correction (FEC), congestion control, automatic
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
System Throughput:
Up/down Link Duplex:
Upgradeability:
Weight:
Ripwave Base Station I&C Guide
repeat request (ARQ), extensive GoS/QoS mechanisms
12 Mbps (fully loaded max raw data rate downstream + upstream)
Symmetrical TDD
Software downloads
100 lbs (indoor BTS), 64 lbs (RFS antenna)
Table 5: Split Chassis System (MMDS & WCS Systems)
Antenna Downtilt:
Antenna Gain:
Antenna Options:
Backhaul Interfaces:
Bandwidth Allocation:
Baseband Modulation:
Beamforming Gain:
Configurations:
DC Power Consumption:
DC Power Interface:
Duplex Format:
Humidity:
Mechanical Dimensions:
Multiple Access Schemes:
Operational Frequency Band:
Operational Temperature:
Polarization:
Power Control:
Regulatory:
Reliability/Availability:
RF Channel Bandwidth:
RF Output Power (per channel):
Sensitivity:
Serviceability:
Spreading Spectrum Scheme:
Storage Temperature:
System Features:
System Throughput:
Up/down Link Duplex:
Upgradeability:
Weight:
Part #40-00047-00 Rev D v1.0
February 28, 2003
2 & 4 degree options for Omni-directional; Mechanical for 120 degree
Sectored
12dBi Omni-directional, 17 dBi for 120-degree Sectored
Omni-directional or 120-degree Sectored
10/100 BaseT Ethernet or ATM over T1; up to (8) T1’s with or without
IMA, long haul support
Dynamic
Uplink QAM4
18dB
RFS Omni-directional or Sectored. 1 BTS per antenna.
21VDC to 28VDC; 1353 Watts typical, 1500 Watts maximum
2 - ¼” lugs for +24V DC and 24V return.
Time Division Duplexing (TDD)
0 to 95% non-condensing
Digital: H19.2” X W19.0” X D12.9” (add ~1.3” to D with modules
installed). RF: H14.0” X W19.0” XD15.2” (add ~1.5” to D with modules
installed).
Multi-carrier Beamforming Synchronized (MCBS) CDMA
See Table 3
0 to +50 degrees C (indoor); -40 to +50 degrees C (outdoor)
Vertical
Forward & reverse, open & closed loop
UL 1950, FCC part 15
Load-sharing
6MHz
5 watts max
-114 dBm/single channel (NF of 5dB)
Field replaceable cards, EMS remote reset; Front and rear access required
Direct Sequence Spreading (DSS)
-40 to +70 degrees C
Reed Soloman forward error correction (FEC), congestion control, automatic
repeat request (ARQ), extensive GoS/QoS mechanisms
12 Mbps (fully loaded max raw data rate downstream + upstream)
Symmetrical or Asymmetrical TDD with a maximum of 3:1 ratio for
down/up allocations
Software downloads
Digital Shelf 35 lbs + RF Shelf 82 lbs.
35
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Materials Specifications
The Base Station installation requires general materials and parts for installation. In Table 6 is a
partial list of the items that may be used for a typical installation of the Ripwave Base Station. A
more complete list is provided in Appendix O. The quantity and use of materials will vary
depending on the specific installation. The lists in Table 6 and in Appendix O are based on a
150-foot site.
Table 6: Materials Specifications
Base Station General Materials Requirements List
BTS Install Kit 96-05000-00
Description
Supplier
Rqd Qty
Lightning Rod
Ground Rod
Ground Wire
Ground Wire
Ground Buss Bar (Tower)
Ground Buss Bar (Shelter)
Ground Lug
Ground Lug
Ground Lug
Grounding Kit (1/2"), LMR600
Grounding Kit (3/8"), LMR400
Grounding Kit (1/2"), RF-1/2"
Universal Grounding kits
GROUNDING
Lightning Rod - 8'
Tinned copper ground rod, 5/8" x 8'
# 2 Stranded green ground wire
# 6 AWG Stranded Green Wire
Ground buss bar kit, 1/4" x 2-1/2" x 12-1/2"
Copper Gnd buss bar, 1/4" x 4", drilled to 5/8"
#6, One Hole
#6, Two Hole
#2, Two Hole
STD Ground kit, LMR-600, 5' x 3/8" 2 hole lug
STD Ground kit, LMR-400, 5' x 3/8" 2 hole lug
Ground Kit, RF-1/2", 2 hole lug
Universal grounding kit, 3' with 3/8" 2 hole lug
MTS
MTS
MTS
LOCKE
MTS
ALT
T&B
T&B
T&B
MTS
MTS
NK Cables
MTS
50 Ft
50 Ft
1 Kit
1 Kit
3 Pcs
6 Pcs
2 Pcs
27 Kits
2 Kits
RFS Antenna
RFS Surge Protector
RFS Antenna Mount
Weatherproofing kits
RFS Antenna Power Cable
RFS Antenna Jumper Cable
Mounting Clamps
Mounting Clamps
RFS Cable
RFS Type N Male Connectors
Hoisting Grips
Cushion Hangers 1/2"
Cushion Hangers 3/8"
Angle Adapter
Cross Cushion Hanger Mounts
Universal Hanger 1/2"
Support Blocks
RFS Connector
RFS Connector
RFS Connector
RFS Connector
36
ANTENNA SYSTEM
Omni Antenna
RFS surge protector
Omni Antenna Mount
Universal weatherproofing kit, Large
RFFE Power/Data Main Cable assembly
RFFE Power/Data Jumper cable, 10 Feet.
Crossover Clamp, 1.5" x 3.5" OD
Pipe to pipe clamps, kit of 2
MAIN FEEDER
LMR 600, 1/2" coaxial cable
EZ600 N type, Male connectors
Pre-laced Hoisting Grip, 1/2"
Cushion hanger assembly, 5H, 1/2", kit of 5
Cushion hanger assembly, 6H, 3/8" for LMR400
Adapter, Galvanized, Angle kit of 10
Cross cushion hanger mount, kit of 5
Hanger, Universal, Snap-In, 1/2", kit of 10
Mini Coax Support Blocks, kit of 10
HUTTON/TIMES
HUTTON/TIMES
MTS
MTS
MTS
MTS
MTS
NK Cables
MTS
MALE, N TYPE, 3/8 INCH
NK Cables
MALE, N TYPE, 5/8 INCH
NK Cables
MALE, N TYPE, 1/2 INCH
NK Cables
MALE, N TYPE, 7/8 INCH
NK Cables
Navini
POLYPHASER
MTS
MTS
Probity
Probity
MTS
MTS
9 Pcs
1 Kit
2 Kits
1 Kit
1 Kit
1 Kit
1 Kit
1350 Ft
36 Pcs
10 Pcs
12 kits
6 Kits
2 Kits
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
RFS Connector
RFS Connector
RFS Connector
RFS Connector
RFS Connector
RFS Connector
Weatherproofing
RFS Cable
RFS Cable
RFS Cable
RFS Cable
GPS Antenna
GPS Surge Protector
GPS Surge Protector
GPS Cable
GPS Type N Male Connectors
Goose Neck - J type Hood entry
Feed Thru Entry Panel
Boot Assembly Kits
Ripwave 2400 BTS
BTS Surge Protector
24 VDC Power Supply
DC Power Wire
DC Power Wire
BREAKER
ROUTER
SERIAL WAN
T1-IMA MODULE
Air conditioning
110 VAC Power Outlets
Telco / Ethernet Connectors RJ45
Ripwave Base Station I&C Guide
FEMALE, N TYPE, 5/8 INCH
NK Cables
FEMALE, N TYPE, 7/8 INCH
NK Cables
N STRAIGHT PLUG, EZ PIN, FEMALE (LMR400)
HUTTON/TIMES
N RIGHT ANGLE, EZ PIN, MALE (LMR400)
HUTTON/TIMES
N RIGHT ANGLE, SOLDER PIN, MALE (LMR400)
HUTTON/TIMES
N STRAIGHT, SOLDER PIN,MALE (LMR400)
HUTTON/TIMES
Sealing Compound, Coax Cable Connector
NK Cables
CABLE, COAX, RF, CORRUGATED, 3/8 INCH
NK Cables
CABLE, COAX, RF, CORRUGATED, 5/8 INCH
NK Cables
CABLE, COAX, RF, CORRUGATED, 1/2 INCH
NK Cables
CABLE, COAX, RF, CORRUGATED, 7/8 INCH
NK Cables
GPS SYSTEM
GPS Antenna, N-type Female
GPS surge protector, Redundant
GPS surge protector, Non-redundant
LMR400, 3/8" coaxial cable
EZ400 N type, Male connectors
ENTRY PORT SYSTEM
Motorola
POLYPHASER
POLYPHASER
HUTTON/TIMES
HUTTON/TIMES
2 Pcs
2 Pcs
1 Pc
200 Ft
8 Pcs
TBD
TBD
MTS
4 Kits
Navini
POLYPHASER
Argus
9 Pcs
1 Unit
Boot Assembly Kit, 4" w/ 4 holes (LMR 600)
BTS SYSTEM
BTS surge protector
# 6 AWG, Stranded, RED Wire
# 6 AWG, Stranded, BLACK Wire
24 VDC, 60A Distribution Breaker
CISCO 2600 Dual 10/100 ENET, WIC/NM Slots
Serial Interface WAN Card, One Port
Multiport T1/E1 Network Module with IMA
Argus
CISCO
CISCO
CISCO
TBD
TBD
TBD
MISCELLANEOUS
Expanding Foam Sealer
Bolts (Ground)
Nuts (Ground)
Flat Washer (Ground)
Lock Washer (Ground)
Star Washer (Ground)
Star Washer (BTS Chassis Ground)
Nut (BTS, Power/Data Surge P)
Equipment Open Rack
Tie wraps
Split Bolt #2/0
Uni-Struts
Anchor/Expansion Bolts
Cable Ladder
Part #40-00047-00 Rev D v1.0
February 28, 2003
Bolt, Hex, 1/4-20 x 1.000 LG, SSPA
Nut, Reg, Hex, Cres, 1/4-20UNC
Wash, Flat, Cres, #6 T-B-Reg .156x.438x.040
Wash, Lock. Split, Cres 1/4, Reg .252x.487x.062
Wash, Star, 1/4
Wash, Star, #10
Nut, Hex, #10-24
Rack, 19" x 72" with 1/4" x 1" holes
TBD
QUESTRON
QUESTRON
QUESTRON
QUESTRON
QUESTRON
QUESTRON
QUESTRON
CHATSWORTH
TBD
TBD
TBD
TBD
TBD
37
Ripwave Base Station I&C Guide
38
Navini Networks, Inc.
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Chapter 2: Installation
Pre-installation
As was shown in Figure 2, prior to installation a number of planning activities take place. The
installation itself takes only about 2 days. The I&C crew usually is not involved with all the preinstallation activities. Of these, they are likely to be most involved in the Site Candidate
Evaluation.
Project Plan
A Project Plan is a document that lays out the work to be done, the objectives of the project, the
schedule, resources required, and so forth. If Navini is performing the I&C activities, a Project
Manager is assigned. The Project Manager prepares the Project Plan and shares it with the
Navini and customer teams.
Coverage Prediction Map
Early in the planning of deployment of Ripwave Base Station equipment, an RF Engineer will go
through the process of studying the RF environment of the candidate sites that the customer has
identified. Readings are taken and analyzed at each site in order to predict what range of
coverage can be expected from installing a Base Station at the site. Coverage predictions account
for both Base Station performance as well as Marketing objectives with the service itself. The
customer accomplishes the latter as part of the decisions concerning site selection.
Site Candidate Evaluation
Often Technicians will be very comfortable with either the networking side or the wireless side
of the system, but not usually both. To evaluate a potential install site, a form is used to ensure
all aspects of the site have been considered. Information is recorded on the form. Since each site
is unique, the form helps to ensure nothing is taken for granted or assumed about the installation
site for the Ripwave equipment. A copy of this form may be found in Appendix B. It includes
places to capture the logistics of the site, tower or rooftop mount possibilities, GPS coordinates,
type of antenna to be installed, whether or not an outdoor enclosure is provided, power
availability, distance between connection points, ventilation, a place for drawings from every
angle, etc. It is from this information that the site will be designed, then installed to plan.
Part #40-00047-00 Rev D v1.0
February 28, 2003
39
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Interference Analysis
The RF Engineer(s) also analyzes existing interference from other sources, and takes that into
account when creating the coverage prediction map. In addition to coverage, though, the
interference analysis also helps to predict the quality of service, the power requirements to get
above the noise floor, and other expectations regarding the site. This study will help Navini and
the customer decide which type of system (frequency) and antenna (panel or omni) will provide
the best results.
Network Architecture Plan
The IP Networking community involved in the project, both from Navini and the customer, work
together to analyze and plan how the Ripwave system will be integrated into the customer’s
network. Of course, they are looking for efficient operation of the system and seamless
integration. They have to plan the traffic routing, IP addressing, protocol compatibility, and so
forth.
Bill of Materials
Someone has to generate the Bill of Materials (BoM) - the actual equipment order to be
manufactured and shipped to the installation site. Navini can provide part numbers and ordering
information, as well as recommendations and other details that will assist customers in the
correct placement of orders. There is a sample Bill of Materials in Appendix O.
Backhaul Connections
The Backhaul connections for the Ripwave Base Station consist of up to two (2) Ethernet cable
connections with RJ-45 connectors for each BTS installed, OR, up to eight (8) T1 connections
with RJ-48 connectors for each BTS. The quantity of each connection will depend on the site
requirements. These connections need to be made available before installation begins.
Power Requirements for the Base Station
The input power source will be determined during the site survey. The DC power source needs to
be an independent hard-wired circuit of 21VDC to 28VDC with a 50-amp breaker for the Combo
Chassis and a 70-amp breaker for the Split Chassis. The power plant return bus must be
connected to an earth ground connection similar to the Base Station chassis. Insulated #6 AWG
cable is recommended. The combo chassis system generates up to 1000 Watts, and the split
chassis system generates up to 1500 Watts maximum; however, 1353 Watts is typical.
40
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Ground Requirements for the Base Station
The Base Station requires an earth ground connection. This ground should exhibit a maximum of
five ohms across true ground.
NOTE: The installation procedures, which begin next, follow the same order as shown in
the I&C Flowchart in Figure 2.
An example of a Base Station drawing for a particular site is provided in Appendix P.
An example of a written Statement of Work (SOW) and Responsibility Assignment Matrix
(RAM) for installation and commissioning are provided in Appendices Q and R. This type of
document may be used in negotiating work between companies and contractor services.
Part #40-00047-00 Rev D v1.0
February 28, 2003
41
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Install Power & Grounding
System Ground Buss Bar & Surge Protectors
The Base Station system ground buss bar and data/power cable surge protectors are mounted on
the wall adjacent to the BTS rack or enclosure. They should be mounted per accepted telecom
standards and procedures.
Step 1.
Mount the data/power cable surge protectors (Figure 7) with the label ‘lines’ toward
the RFS and the label ‘BTS’ toward the BTS.
Step 2.
Apply a thin coat of anti-oxidant joint compound to both sides of the system ground
buss bar to ensure proper connection between it and the surge protectors.
Figure 7: Data/Power Cable Surge Protector
To install the eight (8) antenna and one (1) cal cable surge protectors (Figure 8), and the one (1)
or two (2) Global Positioning System (GPS) surge protectors (Figure 9) in the system ground
buss bar, follow the steps below.
1. Install the rubber gasket into the groove in the surge protector.
2. Install the surge protector in the system ground buss bar with the surge side toward the
antenna and the protected side toward the BTS.
3. Install the star washer and nut on the top of the surge protector. Torque the nut to 140-150
inch-pounds.
4. When finished, the mounted surge protectors in the buss bar will appear as in Figure 10.
42
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Figure 8: Antenna & Cal Cable Surge Protector
Figure 9: GPS Cable Surge Protector
Figure 10: Surge Protectors in Buss Bar
Part #40-00047-00 Rev D v1.0
February 28, 2003
43
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Antenna Ground Buss Bar
You should install the Antenna Ground Buss Bar on the mounting structure per accepted telecom
standards and procedures (Figure 11). The location is decided on during the site survey and
should be close to the RFS. Two or more buss bars may be installed per system.
Figure 11: Buss Bars
BTS Buss Bar
Antenna Buss Bar
System Ground Wiring
A minimum #6 stranded copper, green-coated wire and grounding hardware are used for ground
connections. Install the system ground as a single-point connection between the system ground
buss bars, the data/power surge protector, the BTS chassis, the BTS mounting rack, and the RFS
antenna. Connect the system ground to earth ground. Apply anti-oxidant joint compound to all
connections. Tighten all connections until secure.
44
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Install Cables
All cable connections are made using standard RF coaxial cable. The Navini Networks standard
for cable connections from the GPS to the BTS is LMR 400, 3/8-inch coaxial cable. Other types
of cable that are comparable may be used. Using Tables 7 and 8, determine the size and type of
cable to be used in the installation of the Base Station.
Table 7: Active & Passive RFS Loss / Operating Parameters
PA Max
Output
Power
[dBm]
2.3
+38
BTS Max
Output
power
with
*Filter
[dBm]
+37
CAL
Cable
Min
Loss
CAL
Cable
Max
Loss
RF
Cable
Min
Loss
[dB]
Active
RFS
Loss
Typ
[dB]
Passive
RFS
Loss Typ
[dB]
TX
Pwr
to
Ant Max
[dBm]
RX
Power
to Ant
Min
[dBm]
RX
Power
to Ant
Max
[dBm]
1.7
TX
Pwr
to
Ant
Min
[dBm]
20
3.0
6.0
3.2
35
-95
-75
2.4
+37
N/A
4.0
9.5
3.2
1.7
10
25
-85
-65
2.4
+37
N/A
3.0
4.5
3.2
1.7
18
30
-95
-70
2.5
+39
+38
3.0
6.0
3.2
1.7
20
35
-95
-75
2.6
EF
GH
2.6
EF
+39
+38
3.0
6.0
3.2
1.7
20
35
-95
-75
+37
+35
3.0
4.5
3.2
1.7
20
35
-95
-75
Notes
-05
SYN
-01
SYN
-05
SYN
* Channel filter for 2.5/2.6 or Block Filter for 2.3 has 1.0 +/- 0.2 dB Insertion Loss
* Channel filter for 2.6 EF Combo is 1.8 +/- 0.2 dB including cable to backplane.
Table 8: Cable Attenuation in dB per 100 Feet
Cable Type
2 ¼″
LDF
12-50
5/8″
LDF
750A
LMR
1700
1 ¼″
LDF
650A
LMR
1200
7/8″
LDF
550A
LMR
900
5/8″
LDF
4.550A
½″
LDF
450A
LMR
600
Frequency/Size
2000 MHz
2400 MHz
2500 MHz
2600 MHz
Weight lbs/ft
Bend Radius
inches
2.350
0.994
N/A
N/A
N/A
1.22
24
1.980
1.11
1.24
1.27
1.3
0.82
20
1.670
1.5
1.7
1.71
1.8
0.74
13.5
1.550
1.42
1.5
1.53
1.57
0.63
15
1.200
1.99
2.2
2.26
2.3
0.45
6.5
1.090
1.82
2.02
2.07
2.12
0.33
10
0.870
2.64
2.9
3.1
0.27
0.865
2.27
2.52
2.58
2.64
0.15
0.630
3.25
3.63
3.70
3.78
0.15
0.590
3.9
4.3
4.42
4.5
0.13
1.5
Part #40-00047-00 Rev D v1.0
February 28, 2003
½″
Super
flex
FSJ
450B
0.520
5.09
5.67
5.8
5.94
0.14
LMR
500
3/8″
LDF
250A
LMR
400
0.500
4.84
5.4
5.48
5.6
0.1
1.25
0.440
5.17
5.67
5.91
5.91
0.08
3.75
0.405
6.6
6.8
6.9
0.07
45
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Cable Preparation
The cable run is determined during the site survey. Note that the length of the cables may need to
be slightly different, depending on the position of the buss bar relative to the BTS.
•
Cut nine (9) pieces of cable for the main feeder cables to connect the nine RFS
connectors to the surge protectors on the system ground buss bar. Leave enough extra
length for the service loop below the RFS and for connection to the surge protectors.
•
Cut eight (8) pieces of cable for the jumper cables to connect the surge protectors on the
system ground buss bar to the eight (8) RF input connectors on the back of the BTS.
Leave enough extra cable length for service.
•
Cut one (1) piece of cable for the jumper cable to connect the surge protector on the
system ground buss bar to the CAL connector on the back of the BTS. Leave enough
extra cable length for service.
•
Cut a piece of LMR 400 cable to connect each of the GPS antennas to the surge
protectors on the system ground buss bar. Leave enough extra cable length for service.
The maximum length of the LMR 400 cable for the GPS antenna is 100 feet.
•
Cut a piece of LMR 400 cable to connect the surge protectors on the system ground buss
bar to each GPS connector on the back of the BTS. Leave enough extra cable length for
service. If there is more than one BTS co-located in the installation, two GPS antennas
can serve all BTS’s in the installation.
•
The cable from the GPS antenna (after it goes through the surge protector) is connected
to the antenna input of the GPS distribution amplifier (Figure 12). The output ports of the
GPS distribution amplifier are connected to the GPS inputs of the BTS. The GPS
distribution amplifier is powered by the GPS antenna input. The drawing in Figure 13
depicts the placement of the shared GPS resources among three BTS’s.
Figure 12: GPS Distribution Amplifier
46
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Figure 13: Depiction of GPS Distribution Amplifier
GPS 2
GPS 1
Polyphaser
Polyphaser
SHELTER
Distribution Amp
Distribution Amp
BTS 1
BTS 2
BTS 3
Install Connectors on Cables
Install connectors on both ends of each cable. For LMR 600 cables, install EZ-600 N-type male
connectors. For LMR 400 cables, install EZ-400 N-type male connectors. Steps for installing
both types of connectors can be found in Appendix K. For reference, Appendix L also provides a
list of vendors who can make cables.
Sweep Individual Cables
Sweep each individual cable, the RFS (8) and CAL main feeder and jumper cables, to check for
line loss. Follow the instructions for sweeping the cables provided in Appendix C, entering the
results in the RFS System Test Form. Check continuity of the data/power cable. When finished,
cover the cable connectors for protection until they are connected to the RFS or GPS.
Part #40-00047-00 Rev D v1.0
February 28, 2003
47
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Connectorize & Run Cables
Connect all of the RF cables to the surge protectors in the system ground buss bar. An example
of a buss bar connection is shown in Figure 14. Ensure that the proper cable is connected to the
proper surge protector. Connect the power/data cable to its surge protector. Also connect all the
jumper cables to the surge protectors that will attach to the BTS. Do not connect these cables to
the BTS at this time. Torque all the cable connectors to the surge protectors on the system
ground buss bar to 20-24 inch-pounds.
Figure 14: Buss Bar Connections
RFS 1- 4
GPS 1
CAL
RFS 5- 8
GPS 2
Route all of the cables – RFS (8), CAL, DATA/POWER and GPS (1 or 2) - between the system
ground buss bar and the RFS, and GPS mounting sites. If running the cables up a tower, use a
hoisting grip to lift the cables (Figures 15 and 16).
48
Part #40-00047-00 Rev D v1.0
February 28, 2003
Navini Networks, Inc.
Ripwave Base Station I&C Guide
Figure 15 : Omni Cable Routing
Calibration Cable
RF Cables
Data/Power Cable
Figure 16: Panel Cable Routing
RF Cables
Data/Power
Cable
Calibration Cable
Part #40-00047-00 Rev D v1.0
February 28, 2003
49
Ripwave Base Station I&C Guide
Navini Networks, Inc.
Install the BTS
Install Mounting Rack or Enclosure
The BTS mounting rack (Figure 17) or enclosure is to be installed in compliance with applicable
portions of the National Electrical Code (NEC), articles 800 and 810. You will need to adhere to
local installation standards, as well as Navini Networks standards and procedures. Refer to
Appendix J for guidelines on outdoor BTS enclosures.
Figure 17: BTS Mounting Rack
50
Part #40-00047-00 Rev D v1.0
February 28, 2003

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2003:10:29 09:26:43-06:00
Create Date                     : 2003:10:29 09:26:03-06:00
Title                           : Microsoft Word - ttaicguide.doc
Author                          : BBoyea
Creator                         : Pscript.dll Version 5.0
Producer                        : Acrobat Distiller 5.0 (Windows)
Page Count                      : 50
Mod Date                        : 2003:10:29 09:26:43-06:00
Creation Date                   : 2003:10:29 09:26:03-06:00
Metadata Date                   : 2003:10:29 09:26:43-06:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PL6-BTS-TP1

Navigation menu