Cisco Systems Mds 9500 Series Installation Manual

MDS 9500 Series to the manual 34b5288c-c8b8-43a6-a43c-dd09d9a4251d

2015-01-05

: Cisco-Systems Cisco-Systems-Mds-9500-Series-Installation-Manual-202414 cisco-systems-mds-9500-series-installation-manual-202414 cisco-systems pdf

Open the PDF directly: View PDF PDF.
Page Count: 288 [warning: Documents this large are best viewed by clicking the View PDF Link!]

Send documentation comments to mdsfeedback-doc@cisco.com.
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Cisco MDS 9500 Series Hardware
Installation Guide
October 2008
Text Part Number: OL-17467-02
Send documentation comments to mdsfeedback-doc@cisco.com.
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL
STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT
WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT
SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE
OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required
to correct the interference at their own expense.
The following information is for FCC compliance of Class B devices: The equipment described in this manual generates and may radiate radio-frequency energy. If it is not
installed in accordance with Cisco’s installation instructions, it may cause interference with radio and television reception. This equipment has been tested and found to
comply with the limits for a Class B digital device in accordance with the specifications in part 15 of the FCC rules. These specifications are designed to provide reasonable
protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation.
Modifying the equipment without Cisco’s written authorization may result in the equipment no longer complying with FCC requirements for Class A or Class B digital
devices. In that event, your right to use the equipment may be limited by FCC regulations, and you may be required to correct any interference to radio or television
communications at your own expense.
You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its
peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures:
• Turn the television or radio antenna until the interference stops.
• Move the equipment to one side or the other of the television or radio.
• Move the equipment farther away from the television or radio.
• Plug the equipment into an outlet that is on a different circuit from the television or radio. (That is, make certain the equipment and the television or radio are on circuits
controlled by different circuit breakers or fuses.)
Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public
domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH
ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT
LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF
DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING,
WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO
OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
CCDE, CCENT, Cisco Eos, Cisco Lumin, Cisco Nexus, Cisco StadiumVision, Cisco TelePresence, Cisco WebEx, the Cisco logo, DCE, and Welcome to the Human Network
are trademarks; Changing the Way We Work, Live, Play, and Learn and Cisco Store are service marks; and Access Registrar, Aironet, AsyncOS, Bringing the Meeting To
You, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, CCVP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems,
Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Collaboration Without Limitation, EtherFast, EtherSwitch, Event Center, Fast Step, Follow Me Browsing,
FormShare, GigaDrive, HomeLink, Internet Quotient, IOS, iPhone, iQuick Study, IronPort, the IronPort logo, LightStream, Linksys, MediaTone, MeetingPlace,
MeetingPlace Chime Sound, MGX, Networkers, Networking Academy, Network Registrar, PCNow, PIX, PowerPanels, ProConnect, ScriptShare, SenderBase, SMARTnet,
Spectrum Expert, StackWise, The Fastest Way to Increase Your Internet Quotient, TransPath, WebEx, and the WebEx logo are registered trademarks of Cisco Systems, Inc.
and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or website are the property of their respective owners. The use of the word partner does not imply a partnership relationship
between Cisco and any other company. (0809R)
Cisco MDS 9500 Series Hardware Installation Guide
© 2003–2008 Cisco Systems, Inc. All rights reserved.
Send documentation comments to mdsfeedback-doc@cisco.com.
i
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
CONTENTS
New and Changed Information ix
Preface xv
Audience xv
Organization xv
Conventions xvi
Related Documentation xviii
Release Notes xviii
Compatibility Information xviii
Regulatory Compliance and Safety Information xviii
Hardware Installation xviii
Cisco Fabric Manager xix
Command-Line Interface xix
Intelligent Storage Networking Services Configuration Guides xix
Troubleshooting and Reference xix
Installation and Configuration Note xix
Obtaining Documentation, Obtaining Support, and Security Guidelines xx
CHAPTER
1Product Overview 1-1
Chassis 1-2
Cisco MDS 9513 Director 1-3
Cisco MDS 9509 Director 1-6
Cisco MDS 9506 Director 1-7
Backplane and Clock Modules 1-8
Cisco MDS Fibre Channel Switch for IBM Blade Center 1-9
Power Supplies 1-9
Cisco MDS 9513 Power Supplies 1-10
Cisco MDS 9509 Power Supplies 1-12
Cisco MDS 9506 Power Supplies 1-15
Fan Modules 1-16
Supervisor Modules 1-16
Supervisor-2 Modules 1-17
Control and Management 1-18
Processor 1-18
Send documentation comments to mdsfeedback-doc@cisco.com.
Contents
ii
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Port Interfaces 1-18
LEDs on the Supervisor-2 Module 1-19
Supervisor-1 Modules 1-21
Control and Management 1-21
Crossbar Switching Fabric 1-22
Processor 1-22
Port Interfaces 1-22
LEDs on the Supervisor-1 Module 1-23
Crossbar Modules 1-25
Cisco MDS 9000 Series Module Compatibility 1-27
Port Index Availability 1-28
Switching Modules 1-32
48-port 8-Gbps Fibre Channel Switching Module 1-33
24-port 8-Gbps Fibre Channel Switching Module 1-33
4/44-port 8-Gbps Host-Optimized Fibre Channel Switching Module 1-33
48-Port 4-Gbps Fibre Channel Switching Module 1-34
24-port 4-Gbps Fibre Channel Switching Module 1-35
12-port 4-Gbps Fibre Channel Switching Module 1-35
4-port 10-Gbps Fibre Channel Switching Module 1-36
LEDs on the Generation 2 Switching Modules 1-37
32-Port 2-Gbps Fibre Channel Switching Module 1-37
16-Port 2-Gbps Fibre Channel Switching Module 1-38
Switching Module Features 1-39
LEDs on the Generation 1 Switching Module 1-40
Services Modules 1-41
18/4-Port Multiservice Module 1-41
18/4-Port Multiservice Federal Information Processing Standards Module 1-42
LEDs on the 18/4-Port Multiservice Module 1-43
14/2-Port Multiprotocol Services Module 1-44
LEDs on the MPS-14/2 Module 1-45
IP Storage Services Modules 1-46
LEDs on IP Storage Services Modules 1-47
32-Port Fibre Channel Advanced Services Module 1-48
LEDs on the Fibre Channel Advanced Services Modules 1-49
32-Port Fibre Channel Storage Services Module 1-50
LEDs on the Storage Services Modules 1-51
Caching Services Module 1-52
LEDs on the Caching Services Module 1-54
Supported Transceivers 1-55
Send documentation comments to mdsfeedback-doc@cisco.com.
Contents
iii
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
X2 Transceivers 1-55
Fibre Channel SFP Transceivers 1-56
Combination Fibre Channel/Gigabit Ethernet SFP Transceivers 1-56
CWDM Combination Fibre Channel/Gigabit Ethernet SFP Transceivers 1-56
Gigabit Ethernet SFP Transceivers 1-56
DWDM Fibre Channel SFP Transceivers 1-57
CHAPTER
2Installing the Cisco MDS 9500 Series 2-1
Preinstallation 2-2
Installation Options 2-2
Installation Guidelines 2-3
Required Equipment 2-5
Unpacking and Inspecting the Switch 2-5
Installing the Chassis in a Cabinet or Rack 2-6
Installing the Cisco MDS 9513 Director in a Rack 2-7
Installing the Cisco MDS 9509 Director in a Rack 2-11
Installing the Cisco MDS 9506 Director in a Rack 2-15
System Grounding 2-17
Proper Grounding Practices 2-17
Preventing Electrostatic Discharge Damage 2-19
Establishing the System Ground 2-22
Required Tools and Equipment 2-22
Grounding the Chassis 2-23
Starting Up the Switch 2-28
Connecting the Power Supplies 2-28
Providing Power to an AC Power Supply for the Cisco MDS 9513 Director 2-29
Providing Power to an AC Power Supply for the Cisco MDS 9509 and Cisco MDS 9506
Directors 2-30
Providing Power to a DC Power Supply in the Cisco MDS 9509 Director 2-33
Providing Power to a DC Power Supply in the Cisco MDS 9506 Director 2-34
Powering Up the Switch and Verifying Component Installation 2-36
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules 2-38
Removing Supervisor Modules 2-39
Installing Supervisor Modules 2-40
Removing a Caching Services Module 2-44
Removing Other Switching and Services Modules 2-45
Installing a Switching or Services Module, Including Caching Services Modules 2-45
Verifying Installation of Supervisor, Switching, and Services Modules 2-46
Removing and Installing a Crossbar Module 2-47
Send documentation comments to mdsfeedback-doc@cisco.com.
Contents
iv
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Maintaining a Caching Services Module 2-50
Maintaining the Batteries on the Caching Services Module 2-50
Maintaining the Disk Drives on the Caching Services Module 2-51
Removing and Installing a Power Supply or PEM 2-51
Removing and Installing the Power Supplies on the Cisco MDS 9513 Director 2-52
Removing an AC Power Supply from the Cisco MDS 9513 Director 2-52
Installing an AC Power Supply in the Cisco MDS 9513 Director 2-54
Removing an AC Power Supply from the Cisco MDS 9509 Director 2-56
Installing an AC Power Supply in the Cisco MDS 9509 Director 2-57
Removing a DC Power Supply from the Cisco MDS 9509 Director 2-61
Installing a DC Power Supply in the Cisco MDS 9509 Director 2-62
Removing and Installing the PEMs on the Cisco MDS 9506 Director 2-64
Removing an AC PEM 2-64
Removing a DC PEM 2-64
Installing an AC PEM 2-66
Installing a DC PEM 2-66
Removing an AC or DC Power Supply from the Cisco MDS 9506 Director 2-67
Installing an AC or DC Power Supply in the Cisco MDS 9506 Director 2-67
Removing and Installing Fan Modules 2-68
Removing a Front Fan Module on the Cisco MDS 9513 Director 2-69
Installing a Front Fan Module on the Cisco MDS 9513 Director 2-70
Removing the Crossbar Module Fan Tray 2-71
Installing the Crossbar Module Fan Tray 2-72
Removing a Front Fan Module on the Cisco MDS 9509 Director 2-73
Installing a Front Fan Module on the Cisco MDS 9509 Director 2-73
Removing a Front Fan Module on the Cisco MDS 9506 Director 2-74
Installing a Front Fan Module on the Cisco MDS 9506 Director 2-74
Removing and Installing CompactFlash Cards 2-75
Removing a CompactFlash Card 2-75
Installing a CompactFlash Card 2-76
Removing and Installing Clock Modules 2-76
Removing a Clock Module from the Cisco MDS 9513 Director 2-77
Installing a Clock Module into the Cisco MDS 9513 Director 2-79
Removing a Clock Module from the Cisco MDS 9509 Director 2-80
Installing a Clock Module into the Cisco MDS 9509 Director 2-83
Removing a Clock Module from the Cisco MDS 9506 Director 2-83
Installing a Clock Module into the Cisco MDS 9506 Director 2-86
Send documentation comments to mdsfeedback-doc@cisco.com.
Contents
v
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
APPENDIX
AMigrating to Generation 3 8-Gbps Fibre Channel Switching Modules A-1
Overview A-1
Usage Guidelines A-2
Before You Begin Upgrading the MDS 9513 Director A-3
Migration Procedures for the MDS 9513 Director A-3
Installing the MDS 9000 4/44-Port 8-Gbps Host-Optimized Module A-3
Installing MDS 9513 Fabric 2 Modules and Running Cisco SAN-OS 3.x A-5
Installing MDS 9513 Fabric 2 Modules and Installing MDS 9000 24-port or 48-port 8-Gbps
Modules A-9
Installing the MDS 9513 Fabric 2 Modules and Activating Higher Bandwidth by Reloading the
Switch A-10
Installing the MDS 9513 Fabric 2 Modules and Activating Higher Bandwidth by Powering Down
the Switch A-11
Migration Procedure for the MDS 9509 Director and MDS 9506 Director A-12
CHAPTER
BConnecting the Cisco MDS 9500 Series B-1
Preparing for Network Connections B-2
Connecting to the Console Port B-2
Connecting to the COM1 Port B-4
Connecting to the MGMT 10/100/1000 Ethernet Port B-6
Connecting to the MGMT 10/100 Ethernet Port B-7
Connecting to a Fibre Channel Port B-9
Removing and Installing X2 Transceivers B-9
Removing an X2 Transceiver B-11
Installing an X2 Transceiver B-11
Removing and Installing SFP Transceivers B-12
Removing an SFP Transceiver B-12
Installing an SFP Transceiver B-14
Removing and Installing Cables into SFP Transceivers B-14
Removing a Cable from an SFP Transceiver B-14
Installing a Cable into an SFP Transceiver B-15
Maintaining SFP Transceivers and Fiber-Optic Cables B-16
APPENDIX
CCabinet and Rack Installation C-1
Cabinet and Rack Requirements C-1
General Requirements for Cabinets and Racks C-1
Cabinet and Rack Requirements for the Cisco MDS 9513 Chassis C-2
Cabinet and Rack Requirements for the Cisco MDS 9509 and Cisco MDS 9506 Chassis C-2
Send documentation comments to mdsfeedback-doc@cisco.com.
Contents
vi
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Requirements Specific to Perforated Cabinets C-3
Perforated Cabinet Requirements for the Cisco MDS 9513 Chassis C-3
Perforated Cabinet Requirements for the Cisco MDS 9509 and the Cisco MDS 9506
Chassis C-3
Requirements Specific to Solid-Walled Cabinets C-4
Solid-Walled Cabinet Requirements for the Cisco MDS 9513 Chassis C-4
Solid-Walled Cabinet Requirements for the Cisco MDS 9509 and the Cisco MDS 9506
Chassis C-5
Requirements Specific to Standard Open Racks C-5
Requirements Specific to Two-Post Telco Racks C-6
Cisco MDS 9000 Family Telco and EIA Shelf Bracket C-6
Rack-Mounting Guidelines C-7
Before Installing the Rack-Mount Support Brackets C-7
Before Installing the Shelf Brackets C-8
Required Equipment C-8
Installing the Shelf Bracket Kit into a Two-Post Telco Rack C-9
Installing the Shelf Bracket Kit into a Four-Post EIA Rack C-10
Installing the Switch on the Rack-Mount Support Brackets C-11
Installing the Switch on the Shelf Brackets C-12
Removing the Shelf Bracket Kit (Optional) C-12
Cisco MDS 9500 Shelf Bracket C-13
Rack-Mounting Guidelines C-14
Before Installing the Shelf Brackets C-14
Required Equipment C-14
Installing the Cisco MDS 9500 Shelf Bracket Kit into a Cabinet or Rack C-15
Installing the Switch on the Shelf Brackets C-16
APPENDIX
DTechnical Specifications D-1
Switch Specifications D-1
Module Specifications D-4
Weight of Modules D-5
Power Specifications for the Cisco MDS 9513 Director D-6
Specifications for the Cisco MDS 9513 Power Supplies D-6
Component Power Requirements and Heat Dissipation for the Cisco MDS 9513 Director D-7
AC Power Consumption for the Cisco MDS 9513 Director D-8
Power Specifications for the Cisco MDS 9509 Director D-9
Specifications for the Cisco MDS 9509 Power Supplies D-9
Component Power Requirements and Heat Dissipation for the Cisco MDS 9509 Director D-11
AC Power Consumption for the Cisco MDS 9509 Director D-14
Send documentation comments to mdsfeedback-doc@cisco.com.
Contents
vii
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Power Specifications for the Cisco MDS 9506 Director D-14
Specifications for the Cisco MDS 9506 Power Supplies D-15
Component Power Requirements and Heat Dissipation for the Cisco MDS 9506 Director D-16
AC Power Consumption for the Cisco MDS 9506 Director D-19
X2 Transceiver Specifications D-19
Cisco 10-Gbps Fibre Channel X2 Transceivers D-20
General Specification for Cisco 10-Gbps Fibre Channel X2 Transceivers D-20
Environmental Conditions and Power Requirement Specifications for Cisco 10-Gbps Fibre
Channel X2 Transceivers D-20
Cisco 10-Gbps Ethernet X2 Transceivers D-21
General Specification for Cisco 10-Gbps Ethernet X2 Transceivers D-21
Environmental and Power Requirements Specifications for Cisco 10-Gbps Ethernet X2
Transceiver D-22
Cisco 10-Gbps Ethernet DWDM X2 Transceiver D-22
SFP and SFP+ Transceiver Specifications D-22
Cisco Fibre Channel SFP and SFP+ Transceivers D-23
General Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers D-24
Environmental and Power Requirements for Cisco 8-Gbps Fibre Channel SFP+
Transceivers D-24
General Specifications for Cisco 4-Gbps Fibre Channel SFP Transceivers D-26
Environmental and Power Requirement for Cisco 4-Gbps Fibre Channel SFP Transceivers D-26
General Specifications for Cisco 2-Gbps Fibre Channel SFP Transceivers D-27
Environmental and Power Requirement for Cisco 2-Gbps Fibre Channel SFP Transceivers D-27
Maximum Environmental and Electrical Ratings for Cisco Fibre Channel SFP Transceivers D-28
Cisco Fibre Channel and Gigabit Ethernet Transceivers D-28
General Specifications for Cisco Fibre Channel and Gigabit Ethernet SFP Transceivers D-29
Environmental and Power Requirement Specifications for Cisco Fibre Channel and Gigabit
Ethernet SFP Transceivers D-29
Cisco CWDM SFP Transceivers D-30
Environmental and Optical Specifications for Cisco 2-Gbps CWDM SFP Transceivers D-31
Environmental and Optical Specifications for Cisco 4-Gbps CWDM SFP Transceivers D-33
Cisco Gigabit Ethernet Transceivers D-34
General Specifications for Cisco Gigabit Ethernet Transceivers D-34
Environmental and Power Requirement Specifications for Cisco Gigabit Ethernet
Transceivers D-34
Cisco DWDM SFP Transceivers D-34
APPENDIX
ECable and Port Specifications E-1
Cables and Adapters Provided E-1
Console Port E-2
Send documentation comments to mdsfeedback-doc@cisco.com.
Contents
viii
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Console Port Pinouts E-2
Connecting the Console Port to a Computer Using the DB-25 Adapter E-2
Connecting the Console Port to a Computer Using the DB-9 Adapter E-3
COM1 Port E-3
COM1 Port Pinouts E-3
Connecting the COM1 Port to a Modem E-4
MGMT 10/100/1000 Ethernet Port E-4
MGMT 10/100 Ethernet Port E-6
Supported Power Cords and Plugs E-7
Power Cords E-7
Supported Plugs for 6000-W AC, 2500-W AC, and 1900-W AC Power Supplies E-9
Supported Plugs for the 4000-W AC Power Supply E-11
Jumper Power Cord E-11
Power Supply AC Power Cords E-12
AC Power Cord Illustrations E-13
APPENDIX
FSite Planning and Maintenance Records F-1
Contacting Customer Service F-1
Finding the Chassis Serial Number F-2
Site Preparation Checklist F-4
Contact and Site Information F-6
Chassis and Module Information F-7
Send documentation comments to mdsfeedback-doc@cisco.com.
ix
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
New and Changed Information
This Cisco MDS 9500 Series Hardware Installation Guide applies to Cisco MDS NX-OS Release
4.1(1b) and earlier Cisco MDS SAN-OS releases.
Table 1 lists the new and changed features available with each supported Cisco MDS NX-OS release and
SAN-OS release for the Cisco MDS 9500 Series, with the latest release first.
Note As of NX-OS Release 4.1(1b), SAN-OS has been changed to NX-OS. References to SAN-OS releases
before 4.1(1b) still apply.
Ta b l e 1 Documented Features for the Cisco MDS 9500 Series
Feature Description
Changed in
Release Where Documented
48-port 8-Gbps
Fibre Channel
switching
module
Added 48-port 8-Gbps Fibre Channel
switching module. The switching
module offers 48 autosensing 1-, 2-, 4-
and 8-Gbps Fibre Channel ports and
can be used in the Cisco MDS 9500
Series Switches.
4.1(1b) The “48-port 8-Gbps Fibre
Channel Switching Module”
section on page 1-33 and the
“Technical Specifications”
section on page D-1.
24-port 8-Gbps
Fibre Channel
switching
module
Added 24-port 8-Gbps Fibre Channel
switching module. The switching
module offers 24 autosensing 1-, 2-, 4-
and 8-Gbps Fibre Channel ports and
can be used in the Cisco MDS 9500
Series Switches.
4.1(1b) The “24-port 8-Gbps Fibre
Channel Switching Module”
section on page 1-33 and the
“Technical Specifications”
section on page D-1.
4/44-port
8-Gbps
Host-Optimize
d Fibre
Channel
switching
module
Added 4/44-port 8-Gbps
Host-Optimized Fibre Channel
switching module. The switching
module offers 48 autosensing 1-, 2-, 4-
and 8-Gbps Fibre Channel ports and
can be used in any of the Cisco MDS
9500 Series chassis and in the Cisco
MDS 9222i Switches.
4.1(1b) The “4/44-port 8-Gbps
Host-Optimized Fibre
Channel Switching Module”
section on page 1-33 and the
“Technical Specifications”
section on page D-1.
Send documentation comments to mdsfeedback-doc@cisco.com.
x
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
New and Changed Information
Migration to
Generation 3
modules
Added the information associated with
readying the MDS 9500 Series to
support Generation 3 8-Gbps Fibre
Channel switching modules.
4.1(1b) “Migrating to Generation 3
8-Gbps Fibre Channel
Switching Modules” section
on page A-1.
Crossbar
modules
Added DS-13SLT-FAB2 support 4.1(1b) “Technical Specifications”
section on page D-1.
SFP+
transceivers
Added the SFP+ transceivers
information.
4.1(1b) “Technical Specifications”
section on page D-1.
Cisco MDS
Fibre Channel
Bladeswitch
overview
Description of the Cisco MDS Fibre
Channel Bladeswitch for IBM
BladeCenter.
3.3(1a) Product Overview chapter.
18/4-port
Multiservice
(MSM-18/4)
module
Added information on IPV6 support. 3.3(1a) Product Overview chapter.
18/4-port
Multiservice
(MSM-18/4)
module
Added information on SAN extension
support.
3.3(1a) The “18/4-Port Multiservice
Module” section on
page 1-41.
18/4-port
Multiservice
(MSM-18/4)
module
Added the Storage Media Encryption
information.
3.2(1) The “18/4-Port Multiservice
Module” section on
page 1-41.
18/4-port
Multiservice
(MSM-18/4)
module
Added the new 18/4-port Multiservice
(MSM-18/4) module.
3.2(1) The “18/4-Port Multiservice
Module” section on page 1-41
and the “Technical
Specifications” section on
page D-1.
18/4-port
Multiservice
FIPS
(MSFM-18/4)
module
Added the new 18/4-port Multiservice
FIPS (MSFM-18/4) module.
3.2(1) The “18/4-Port Multiservice
Federal Information
Processing Standards
Module” section on page 1-42
and the “Technical
Specifications” section on
page D-1.
Cisco MDS
9513 Multilayer
Director
Added Cisco MDS 9513 Multilayer
Director. The chassis consists of 13
horizontal slots, where slots 1 to 6 and
slots 9 to 13 are reserved for switching,
services, and IPS modules, and slots 7
and 8 are for Supervisor-2 modules
only.
3.0(1) The “Chassis” section on
page 1-2 and the “Installing
the Cisco MDS 9513 Director
in a Rack” section on
page 2-7.
Table 1 Documented Features for the Cisco MDS 9500 Series (continued)
Feature Description
Changed in
Release Where Documented
Send documentation comments to mdsfeedback-doc@cisco.com.
xi
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
New and Changed Information
Supervisor-2
module
Added Supervisor-2 module.
Supervisor-2 modules can be used in
the Cisco MDS 9509 and 9506 Director
in slots 5 and 6. Dual Supervisor-2
modules must be used in slots 7 and 8
of the Cisco MDS 9513 Director.
3.0(1) The “Supervisor-2 Modules”
section on page 1-17.
48-port 4-Gbps
Fibre Channel
switching
module
Added 48-port 4-Gbps Fibre Channel
switching module. The switching
module offers 48 autosensing 1-, 2-,
and 4-Gbps Fibre Channel ports and
can be used in any of the Cisco MDS
9500 Series chassis and in the Cisco
MDS 9216i and 9216A Switches.
3.0(1) The “48-Port 4-Gbps Fibre
Channel Switching Module”
section on page 1-34 and the
“Technical Specifications”
section on page D-1.
24-port 4-Gbps
Fibre Channel
switching
module
Added 24-port 4-Gbps Fibre Channel
switching module. The switching
module offers 24 autosensing 1-, 2-,
and 4-Gbps Fibre Channel ports and
can be used in any of the Cisco MDS
9500 Series chassis and in the Cisco
MDS 9216i and 9216A Switches.
3.0(1) The “24-port 4-Gbps Fibre
Channel Switching Module”
section on page 1-35 and the
“Technical Specifications”
section on page D-1.
12-port 4-Gbps
Fibre Channel
switching
module
Added 12-port 4-Gbps Fibre Channel
switching module. The switching
module can be used in any of the Cisco
MDS 9500 Series chassis and in the
Cisco MDS 9216i and 9216A Switches.
3.0(1) The “12-port 4-Gbps Fibre
Channel Switching Module”
section on page 1-35 and the
“Technical Specifications”
section on page D-1.
4-port 10-Gbps
Fibre Channel
switching
module
Added 4-port 10-Gbps Fibre Channel
switching module. The switching
module offers four dedicated
bandwidth Fibre Channel ports running
at 10 Gbps with no oversubscription.
3.0(1) The “4-port 10-Gbps Fibre
Channel Switching Module”
section on page 1-36 and
“Technical Specifications”
section on page D-1.
Crossbar
modules
Added crossbar modules. The Cisco
MDS 9513 Director supports two
crossbar modules located at the rear of
the chassis. Each Supervisor-2 module
has an associated crossbar module.
3.0(1) The “Crossbar Modules”
section on page 1-25 and
“Removing and Installing a
Crossbar Module” section on
page 2-47.
X2 transceiver Added the X2 transceiver information.
The X2 transceiver is a small
form-factor pluggable optimized for
10-Gbps applications.
3.0(1) The “X2 Transceivers” section
on page 1-55 and the “X2
Transceiver Specifications”
section on page 19.
Fibre Channel
SFP transceiver
Added 4-Gbps Fibre Channel SFP trans-
ceiver.
3.0(1) The “Fibre Channel SFP
Transceivers” section on
page 1-56 and the “SFP and
SFP+ Transceiver
Specifications” section on
page D-22.
Table 1 Documented Features for the Cisco MDS 9500 Series (continued)
Feature Description
Changed in
Release Where Documented
Send documentation comments to mdsfeedback-doc@cisco.com.
xii
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
New and Changed Information
3000W Power
Supply for the
Cisco MDS
9509 Director
Added 3000W power supply for the
Cisco MDS 9509 Director.
3.0(1) The “Cisco MDS 9509 Power
Supplies” section on
page 1-12, “Installing an AC
Power Supply in the Cisco
MDS 9509 Director” section
on page 2-57, and the
“Specifications for the Cisco
MDS 9509 Power Supplies”
section on page D-9.
Gigabit
Ethernet SFP
transceiver
Added Gigabit Ethernet SFP
transceiver.
Not release
specific
The “Supported Transceivers”
section on page 1-55 and the
“SFP and SFP+ Transceiver
Specifications” section on
page D-22.
32-port Fibre
Channel
Storage
Services
Module (SSM)
Added 32-port Fibre Channel Storage
Services Module (SSM).
2.0(2b) The “32-Port Fibre Channel
Storage Services Module”
section on page 1-50.
14/2-port
Multiprotocol
Services
(MPS-14/2)
module
Provided FCIP, iSCSI, and Fibre
Channel capability in a multiprotocol
module.
2.0(1b) The “14/2-Port Multiprotocol
Services Module” section on
page 1-44.
Clock module
installation
Added installation procedure for clock
modules.
Not release
specific
The “Removing and Installing
Clock Modules” section on
page 2-76.
9500 Shelf Kit Added optional shelf bracket kit for the
Cisco MDS 9509 Director.
Not release
specific
The “Cisco MDS 9500 Shelf
Bracket” section on
page C-13.
4-port IP
Storage
Services
(IPS-4) module
Provided FCIP services and iSCSI
services capability in a 4-port Gigabit
Ethernet module.
1.3(4a) The “IP Storage Services
Modules” section on
page 1-46.
Jumper power
cord
Added jumper power cord available for
use in a cabinet.
Not release
specific
The “Jumper Power Cord”
section on page E-11.
Installation Modified Cisco MDS 9509 installation
options.
Not release
specific
The “Installation Options”
section on page 2-2.
Power supplies Added information on Cisco MDS
9509 power supplies.
Not release
specific
The “Installing the Cisco
MDS 9509 Director in a
Rack” section on page 2-11.
Table 1 Documented Features for the Cisco MDS 9500 Series (continued)
Feature Description
Changed in
Release Where Documented
Send documentation comments to mdsfeedback-doc@cisco.com.
xiii
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
New and Changed Information
Installation of
SFP
transceivers
Added instructions for installation and
removal of SFP transceivers and cables.
Not release
specific
The “Removing, Installing,
and Verifying Supervisor,
Switching, and Services
Modules” section on
page 2-38.
Additional UK
power cable
Added United Kingdom power cable
BS89/13, BS 1363/A, for use with
1900-W power supply.
Not release
specific
The “Power Cords” section on
page E-7.
Caching
Services
Module (CSM)
Added virtualization services for
reallocating physical resources as
virtual resources.
1.3(1) The “32-Port 2-Gbps Fibre
Channel Switching Module”
section on page 1-37.
Telco and EIA
Shelf Bracket
Kit
Allowed single-user installation and
installation in a telco rack.
Not release
specific
The “Cisco MDS 9000 Family
Telco and EIA Shelf Bracket”
section on page C-6.
Advanced
Services
Module (ASM)
Added support for up to 32 Fibre
Channel ports, provided distributed
intelligent storage services, and
enabled virtualization.
1.2(2a) The “32-Port Fibre Channel
Advanced Services Module”
section on page 1-48.
Console port to
modem
Connection
Added support for connecting the
console port on the Cisco MDS 9500
Series to a modem.
1.2(2a) The “Connecting to the
Console Port” section on
page B-2.
COM1 port to
modem
Connection
Added support for connecting the
COM1 port on the Cisco MDS 9500
Series to a modem.
1.2(1a) The “Connecting to the COM1
Port” section on page B-4.
Gigabit
Ethernet and
CWDM SFP
transceivers
Added support for Gigabit
Ethernet/Fibre Channel SFP
transceivers and CWDM SFP
transceivers.
1.1(1a) The “Supported Transceivers”
section on page 1-55.
8-port IP
Storage
Services
(IPS-8) module
Provided FCIP services and iSCSI
services capability in an 8-port Gigabit
Ethernet module.
1.1(1a) The “IP Storage Services
Modules” section on
page 1-46.
Cisco MDS
9506 Director
Added the Cisco MDS 9506 Director, a
multilayer Fibre Channel switch that
supports up to six modules.
1.1(1a) This guide.
16-port Fibre
Channel
module
Added 16-port Fibre Channel
hot-swappable switching module for
use with the Cisco MDS 9500 Series.
1.0(2a) The “Switching Modules”
section on page 1-32.
32-port Fibre
Channel
module
Added 32-port Fibre Channel
hot-swappable switching module for
use with the Cisco MDS 9500 Series.
1.0(2a) The “Switching Modules”
section on page 1-32.
Cisco MDS
9509 Switch
Added the Cisco MDS 9509 Director, a
multilayer Fibre Channel switch that
supports up to nine modules.
1.0(2a) This guide.
Table 1 Documented Features for the Cisco MDS 9500 Series (continued)
Feature Description
Changed in
Release Where Documented
Send documentation comments to mdsfeedback-doc@cisco.com.
xiv
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
New and Changed Information
Send documentation comments to mdsfeedback-doc@cisco.com.
xv
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Preface
This preface describes the audience, organization, and conventions of the
Cisco MDS 9500 Series Hardware Installation Guide. It also provides information on how to obtain
related documentation.
Audience
To use this installation guide, you must be familiar with electronic circuitry and wiring practices and
preferably be an electronic or electromechanical technician.
Organization
This guide is organized as follows:
Chapter Title Description
Chapter 1Product Overview Provides an overview of the Cisco MDS 9500 Series and its
components.
Chapter 2Installing the Cisco
MDS 9500 Series
Describes how to install the Cisco MDS 9500 Series, including
installing the chassis, modules, CompactFlash card, power
supplies, and fan assembly.
Chapter BConnecting the
Cisco MDS 9500
Series
Describes how to connect the Cisco MDS 9500 Series, including
the modules.
Appendix AMigrating to
Generation 3
8-Gbps Fibre
Channel Switching
Modules
Describes the tasks associated with readying the MDS 9500 Series
to support Generation 3 8-Gbps Fibre Channel switching modules.
Appendix CCabinet and Rack
Installation
Provides guidelines for selecting an enclosed cabinet, and the
procedure for installing a switch using the optional Telco and EIA
Shelf Bracket Kit.
Appendix DTechnical
Specifications
Lists the Cisco MDS 9500 Series switch specifications, and
includes safety information, site requirements, and power
connections.
Send documentation comments to mdsfeedback-doc@cisco.com.
xvi
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Preface
Conventions
This document uses the following conventions for notes, cautions, and safety warnings.
Notes and Cautions contain important information that you should be aware of.
Note Means reader take note. Notes contain helpful suggestions or references to material that
are not covered in the publication.
Caution Means reader be careful. You are capable of doing something that might result in equipment damage or
loss of data.
Safety warnings appear throughout this publication in procedures that, if performed incorrectly, may
harm you. A warning symbol precedes each warning statement.
Appendix ECable and Port
Specifications
Lists cable and port specifications for the Cisco MDS 9500 Series
switch.
Appendix FSite Planning and
Maintenance
Records
Provides a site-planning checklist and sample maintenance and
network records.
Chapter Title Description
Warning
This warning symbol means danger. You are in a situation that could cause
bodily injury. Before you work on any equipment, be aware of the hazards
involved with electrical circuitry and be familiar with standard practices for
preventing accidents. Use the statement number provided at the end of each
warning to locate its translation in the translated safety warnings that
accompanied this device.
Statement 1071
Waarschuwing
Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die
lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat
werken, dient u zich bewust te zijn van de bij elektrische schakelingen
betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen
om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die in
deze publicatie verschijnen, kunt u het document Regulatory Compliance and
Safety Information (Informatie over naleving van veiligheids- en andere
voorschriften) raadplegen dat bij dit toestel is ingesloten.
Varoitus
Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa
ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota
selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista
onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien varoitusten
käännökset löydät laitteen mukana olevasta Regulatory Compliance and
Safety Information -kirjasesta (määräysten noudattaminen ja tietoa
turvallisuudesta).
Send documentation comments to mdsfeedback-doc@cisco.com.
xvii
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Preface
Attention
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une
situation pouvant causer des blessures ou des dommages corporels. Avant de
travailler sur un équipement, soyez conscient des dangers posés par les
circuits électriques et familiarisez-vous avec les procédures couramment
utilisées pour éviter les accidents. Pour prendre connaissance des
traductions d’avertissements figurant dans cette publication, consultez le
document Regulatory Compliance and Safety Information (Conformité aux
règlements et consignes de sécurité) qui accompagne cet appareil.
Warnung
Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die
zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an
irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen
Stromkreisen verbundenen Gefahren und der Standardpraktiken zur
Vermeidung von Unfällen bewußt. Übersetzungen der in dieser
Veröffentlichung enthaltenen Warnhinweise finden Sie im Dokument
Regulatory Compliance and Safety Information (Informationen zu
behördlichen Vorschriften und Sicherheit), das zusammen mit diesem Gerät
geliefert wurde.
Avvertenza
Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe
causare infortuni alle persone. Prima di lavorare su qualsiasi
apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed
essere al corrente delle pratiche standard per la prevenzione di incidenti. La
traduzione delle avvertenze riportate in questa pubblicazione si trova nel
documento Regulatory Compliance and Safety Information (Conformità alle
norme e informazioni sulla sicurezza) che accompagna questo dispositivo.
Advarsel
Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre
til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de
faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med
vanlig praksis når det gjelder å unngå ulykker. Hvis du vil se oversettelser av
de advarslene som finnes i denne publikasjonen, kan du se i dokumentet
Regulatory Compliance and Safety Information (Overholdelse av forskrifter og
sikkerhetsinformasjon) som ble levert med denne enheten.
Aviso
Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe
poderá causar danos físicos. Antes de começar a trabalhar com qualquer
equipamento, familiarize-se com os perigos relacionados com circuitos
eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis
acidentes. Para ver as traduções dos avisos que constam desta publicação,
consulte o documento Regulatory Compliance and Safety Information
(Informação de Segurança e Disposições Reguladoras) que acompanha este
dispositivo.
¡Advertencia!
Este símbolo de aviso significa peligro. Existe riesgo para su integridad física.
Antes de manipular cualquier equipo, considerar los riesgos que entraña la
corriente eléctrica y familiarizarse con los procedimientos estándar de
prevención de accidentes. Para ver una traducción de las advertencias que
aparecen en esta publicación, consultar el documento titulado Regulatory
Compliance and Safety Information (Información sobre seguridad y
conformidad con las disposiciones reglamentarias) que se acompaña con
este dispositivo.
Send documentation comments to mdsfeedback-doc@cisco.com.
xviii
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Preface
Related Documentation
The documentation set for the Cisco MDS 9000 Family includes the following documents. To find a
document online, use the Cisco MDS NX-OS Documentation Locator at:
http://www.cisco.com/en/US/docs/storage/san_switches/mds9000/roadmaps/doclocater.htm.
Release Notes
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Releases
Cisco MDS 9000 Family Release Notes for Storage Services Interface Images
Cisco MDS 9000 Family Release Notes for Cisco MDS 9000 EPLD Images
Compatibility Information
Cisco MDS 9000 NX-OS Hardware and Software Compatibility Information
Cisco MDS 9000 Family Interoperability Support Matrix
Cisco MDS Storage Services Module Interoperability Support Matrix
Cisco MDS NX-OS Release Compatibility Matrix for Storage Service Interface Images
Regulatory Compliance and Safety Information
Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family
Hardware Installation
Cisco MDS 9124 Multilayer Fabric Switch Quick Start Guide
Cisco MDS 9500 Series Hardware Installation Guide
Cisco MDS 9200 Series Hardware Installation Guide
Cisco MDS 9100 Series Hardware Installation Guide
Varning!
Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan
leda till personskada. Innan du utför arbete på någon utrustning måste du vara
medveten om farorna med elkretsar och känna till vanligt förfarande för att
förebygga skador. Se förklaringar av de varningar som förkommer i denna
publikation i dokumentet Regulatory Compliance and Safety Information
(Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer
denna anordning.
Send documentation comments to mdsfeedback-doc@cisco.com.
xix
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Preface
Cisco Fabric Manager
Cisco MDS 9000 Family Fabric Manager Quick Configuration Guide
Cisco MDS 9000 Family Fabric Manager Configuration Guide
Cisco MDS 9000 Family Fabric Manager Database Schema
Cisco MDS 9000 Family Data Mobility Manager Configuration Guide
Command-Line Interface
Cisco MDS 9000 Family Software Upgrade and Downgrade Guide
Cisco MDS 9000 Family Storage Services Module Software Installation and Upgrade Guide
Cisco MDS 9000 Family CLI Quick Configuration Guide
Cisco MDS 9000 Family CLI Configuration Guide
Cisco MDS 9000 Family Command Reference
Intelligent Storage Networking Services Configuration Guides
Cisco MDS 9000 Family Data Mobility Manager Configuration Guide
Cisco MDS 9000 Family Storage Media Encryption Configuration Guide
Cisco MDS 9000 Family Secure Erase Configuration Guide - For Cisco MDS 9500 and 9200 Series
Troubleshooting and Reference
Cisco MDS 9000 Family Troubleshooting Guide
Cisco MDS 9000 Family MIB Quick Reference
Cisco MDS 9000 Family SMI-S Programming Reference
Cisco MDS 9000 Family System Messages Reference
Installation and Configuration Note
Cisco MDS 9000 Family SSM Configuration Note
Cisco MDS 9000 Family Port Analyzer Adapter Installation and Configuration Note
Cisco 10-Gigabit X2 Transceiver Module Installation Note
Cisco MDS 9000 Family CWDM SFP Installation Note
Cisco MDS 9000 Family CWDM Passive Optical System Installation Note
Send documentation comments to mdsfeedback-doc@cisco.com.
xx
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Preface
Obtaining Documentation, Obtaining Support, and Security
Guidelines
For information on obtaining documentation, submitting a service request, and gathering additional
information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and
revised Cisco technical documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed
and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free
service and Cisco currently supports RSS version 2.0.
CHAPTER
Send documentation comments to mdsfeedback-doc@cisco.com.
1-1
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
1
Product Overview
The Cisco MDS 9500 Multilayer Director elevates the standard for director-class switches. Providing
industry-leading availability, scalability, security, and management, the Cisco MDS 9500 Series allows
deployment of high-performance SANs with lowest total cost of ownership. Layering a rich set of
intelligent features onto a high-performance, protocol-agnostic switch fabric, the Cisco MDS 9500
Series of Multilayer Directors addresses the stringent requirements of large data-center storage
environments: uncompromisingly high availability, security, scalability, ease of management, and
transparent integration of new technologies.
The Cisco MDS 9500 Series includes the Cisco MDS 9513 Director, the Cisco MDS 9509 Director, and
the Cisco MDS 9506 Director, which all provide the following high availability features:
Redundant Supervisor-2 modules with associated external crossbar modules for the Cisco MDS
9513 Director.
Redundant Supervisor-2 modules with associated integrated crossbar modules for the Cisco MDS
9509 and 9506 Directors.
Redundant Supervisor-1 modules with dual switching fabrics for the Cisco MDS 9509 and 9506
Directors.
Optional hot-swappable switching or services modules.
Switching module port interfaces that support field-replaceable, hot-swappable, form-factor
pluggable X2 transceivers.
Switching module port interfaces that support field-replaceable, hot-swappable, small form-factor
pluggable (SFP) and Enhanced small form-factor pluggable (SFP+) transceivers.
Redundant and hot-swappable power supplies and fan modules.
Power and cooling management and environmental monitoring.
Nondisruptive code load and activation.
Redundant and self-monitoring system clocks.
For more information about high availability features, redundant supervisor operation, and how to
configure the Cisco MDS 9500 Series, see the Cisco MDS 9000 Family CLI Configuration Guide and
the Cisco MDS 9000 Family Fabric Manager Configuration Guide.
The Cisco MDS 9500 Series supports the following hot-swappable, field-replaceable modules:
48-port 8-Gbps Fibre Channel switching module (DS-X9248-96K9)
24-port 8-Gbps Fibre Channel switching module (DS-X9224-96K9)
4/44-port 8-Gbps Host-Optimized Fibre Channel switching module (DS-X9248-48K9)
Send documentation comments to mdsfeedback-doc@cisco.com.
1-2
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Chassis
48-port 4-Gbps Fibre Channel switching module (DS-X9148)
24-port 4-Gbps Fibre Channel switching module (DS-X9124)
12-port 4-Gbps Fibre Channel switching module (DS-X9112)
4-port 10-Gbps Fibre Channel switching module (DS-X9704)
32-port 2-Gbps Fibre Channel switching module (DS-X9032)
16-port 2-Gbps Fibre Channel switching module (DS-X9016)
18/4-port Multiservice (MSM-18/4) module (DS-X9304-18K9)
18/4-port Multiservice FIPS (MSFM-18/4) module (DS-X9304-18FK9)
14/2-port Multiprotocol Services (MPS-14/2) module (DS-X9302-14K9)
8-port IP Storage Services (IPS-8) module (DS-X9308-SMIP)
4-port IP Storage Services (IPS-4) module (DS-X9304-SMIP)
Storage Services Module (SSM) (DS-X9032-SSM)
Advanced Services Module (ASM) (DS-X9032-SMV)
Caching Services Module (CSM) (DS-X9560-SMC)
This chapter includes the following sections:
Chassis, page 1-2
Backplane and Clock Modules, page 1-8
Cisco MDS Fibre Channel Switch for IBM Blade Center, page 1-9
Power Supplies, page 1-9
Fan Modules, page 1-16
Supervisor Modules, page 1-16
Crossbar Modules, page 1-25
Cisco MDS 9000 Series Module Compatibility, page 1-27
Port Index Availability, page 1-28
Switching Modules, page 1-32
Services Modules, page 1-41
Supported Transceivers, page 1-55
Chassis
This section describes the different chassis offerings in the Cisco MDS 9500 Series:
Cisco MDS 9513 Director, page 1-3
Cisco MDS 9509 Director, page 1-6
Cisco MDS 9506 Director, page 1-7
Send documentation comments to mdsfeedback-doc@cisco.com.
1-3
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Chassis
Cisco MDS 9513 Director
The Cisco MDS 9513 Director is a 13-slot Fibre Channel switch. The front panel consists of 13
horizontal slots, where slots 1 to 6 and slots 9 to 13 are reserved for switching and services modules only,
and slots 7 and 8 are for Supervisor-2 modules only. A variable speed fan tray, with 15 individual fans,
is located on the front left panel of the chassis.
The Cisco MDS 9513 Director uses a midplane. Modules exist on both sides of the plane. (See
Figure 1-1.) The Cisco MDS 9513 Director supports the following:
Two Supervisor-2 modules that reside in slots 7 and 8.
Switching and storage services modules. (See the “Port Index Availability” section on page 1-28 for
possible configurations.)
One hot-swappable front panel fan tray with redundant individual fans.
Two power supplies located at the rear of the chassis. The power supplies are redundant by default
and can be configured to be combined if desired.
Two crossbar modules located at the rear of the chassis.
One hot-swappable fan module for the crossbar modules located at the rear of the chassis.
Two hot-swappable clock modules located at the rear of the chassis.
Note The Cisco MDS 9513 Director does not support the Advanced Services Module (ASM) or the Caching
Services Module (CSM).
Send documentation comments to mdsfeedback-doc@cisco.com.
1-4
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Chassis
Figure 1-1 Cisco MDS 9513 Chassis Front Panel View
The rear of the chassis supports two vertical, redundant power supplies, two clock modules, two vertical,
redundant, external crossbar modules, and a variable speed fan tray with two individual fans located
above the crossbar modules. (See Figure 1-2.)
1Switching or services modules in slots 1–6 3Switching or services modules in slots 9–13
2Supervisor-2 modules in slots 7 and 8 4Fan tray
144465
1
2
3
4
Send documentation comments to mdsfeedback-doc@cisco.com.
1-5
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Chassis
Figure 1-2 Rear Panel 9513 Chassis
1Power supplies 4Air vent panels
2crossbar module fans 5Clock module1
1. Clock modules are located inside the air vent panel. You must remove the air vent panel to access the clock modules.
3crossbar modules
144426
12
3
45
Send documentation comments to mdsfeedback-doc@cisco.com.
1-6
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Chassis
Cisco MDS 9509 Director
The Cisco MDS 9509 Director has a 9-slot chassis as shown in Figure 1-3, and it supports the following:
Redundant Supervisor-2 modules with associated internal crossbar modules.
Up to two Supervisor-1 modules that provide a switching fabric, plus a console port, COM1 port,
and a MGMT 10/100 Ethernet port on each module. Slots 5 and 6 are reserved for the supervisor
modules.
Seven slots for optional modules that can include up to seven switching modules or six IPS modules.
Two power supplies located in the front of the chassis. The power supplies are redundant by default
and can be configured to be combined if desired.
One hot-swappable fan module with redundant fans.
Figure 1-3 Cisco MDS 9509 Chassis
1Switching or services modules in
slots 1–4
5Fan module
2Supervisor module in slot 5 6Power supply 1
3Redundant supervisor module in
slot 6
7ESD socket
4Switching or services modules in
slots 7–9
8Power supply 2 (redundant)
91692
1
4
56
8
7
2
3
Send documentation comments to mdsfeedback-doc@cisco.com.
1-7
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Chassis
Cisco MDS 9506 Director
The Cisco MDS 9506 Director has a 6-slot chassis as shown in Figure 1-4, and it supports the following:
Up to two Supervisor-1 modules that provide a switching fabric, with a console port, COM1 port,
and a MGMT 10/100 Ethernet port on each module. Slots 5 and 6 are reserved for the supervisor
modules.
Four slots for optional modules that can include up to four switching modules or three IPS modules.
Two power supplies located in the back of the chassis. The power supplies are redundant by default
and can be configured to be combined if desired.
Two power entry modules (PEMs) in the front of the chassis for easy access to power supply
connectors and switches.
One hot-swappable fan module with redundant fans.
Figure 1-4 Cisco MDS 9506 Chassis
1Switching or services modules in slots 1–4 4ESD Socket
2Supervisor modules in slots 5 and 6 5Power supplies (in back)
3Fan module 6Location of power entry modules (PEMs) --
one PEM shown and one filler panel shown.
91580
1
2
3
4
6
5
Send documentation comments to mdsfeedback-doc@cisco.com.
1-8
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Backplane and Clock Modules
Backplane and Clock Modules
The Cisco MDS 9500 Series includes one or more clock modules that are accessible from the back of
the chassis. The Cisco MDS 9513 and 9509 Directors have two field-replaceable clock modules for
redundancy and failover. The Cisco MDS 9506 Director has one field-replaceable clock module. In the
unlikely event of a clock module failure, the Cisco MDS 9500 Series generates an error message and a
switchover from one clock module to the other, causing the system to reset automatically. Cisco
recommends that the failed clock module be replaced during a maintenance window. See the “Removing
and Installing Clock Modules” section on page 2-76 for information on replacing clock modules.
There are two LEDs per clock module. Figure 1-5 shows the upper and lower LEDs.
Figure 1-5 Clock Module LEDs
1Lower LEDs 2Upper LEDs
Ta b l e 1-1 Clock LEDs for the Cisco MDS 9500 Series Directors
LED Status Description
Upper LED Green Clock module is active and in use.
Off Clock module is in standby mode.
Lower LED Green Power supply is on and working properly.
Red Power supply is not in a stable state. If this
indication continues after initial power on, check
that all connections are secure.
Off Normal operation or power supply is turned off.
181336
1
2
CLOCK A CLOCK B
Send documentation comments to mdsfeedback-doc@cisco.com.
1-9
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Cisco MDS Fibre Channel Switch for IBM Blade Center
Cisco MDS Fibre Channel Switch for IBM Blade Center
The Cisco MDS Fibre Channel Bladeswitch for IBM BladeCenter is designed for IBM BladeCenter
environments. The Cisco MDS Fibre Channel Bladeswitch is based on the Cisco MDS 9000 Family SAN
switching technology, which integrates the Cisco MDS 9000 Family of switches and directors into a
blade-switch architecture. The advanced architecture of the Cisco MDS Fibre Channel Bladeswitch for
IBM BladeCenter, along with 4-Gb technology, provides outstanding performance between
Bladeswitches and the rest of the Fibre Channel infrastructure.
The Cisco MDS Fibre Channel Bladeswitch for IBM BladeCenter provides 4-Gb Fibre Channel
performance to blade-server switching. It also provides network intelligence features such as virtual
SANs (VSANs), quality of service (QoS), and N-port interface virtualization (NPIV). It also offers
nondisruptive software upgrades and on-demand port activation and is the most complete embedded
Fibre Channel switching available for the IBM BladeCenter, BladeCenter-T, and BladeCenter-H
platforms.
The Cisco MDS Fibre Channel Bladeswitch for IBM BladeCenter provides up to 20 nonblocking 1-, 2-,
and 4-Gb Fibre Channel ports that are available in two configurations: 7 internal ports and 3 external
ports, or 14 internal ports and 6 external ports. Each port provides line-rate performance up to 4-Gb
without any performance loss for integrated features such as VSANs, QoS, or Network Address
Translation (NAT). The Cisco MDS Fibre Channel Bladeswitch for IBM BladeCenter supports up to 16
VSANs per blade switch.
Each external port on the Cisco MDS FC Bladeswitch for IBM BladeCenter also provides line-rate
performance up to 4-Gb for Inter-Switch Links (ISLs) or additional device connectivity such as storage
or host bus adapters (HBAs).
The Cisco NX-OS software provides role-based access control (RBAC) for management access of the
Cisco Fibre Channel Bladeswitch for IBM BladeCenter command-line interface (CLI) and Simple
Network Management Protocol (SNMP). For more information, see the Cisco 9000 Family Command
Reference.
Power Supplies
The Cisco MDS 9500 Series supports dual hot-swappable power supplies, each of which is capable of
supplying sufficient power to the entire chassis should one power supply fail. The power supplies
monitor their output voltage and provide status to the supervisor modules. To prevent the unexpected
shutdown of an optional module, the power management software only allows a module to power up if
adequate power is available.
The power supplies can be configured to be redundant or combined. By default, they are configured as
redundant, so that if one fails, the remaining power supply can still power the entire system. For
information about how to configure the power supplies, see the Cisco MDS 9000 CLI Family
Configuration Guide.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-10
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Power Supplies
Cisco MDS 9513 Power Supplies
The Cisco MDS 9513 Director supports the 6000-W AC power supply (AC input). (See Figure 1-6.)
Figure 1-6 Cisco MDS 9513 Power Supply
1Power supply switch 3Power Supply LEDs
2AC power connection
144466
3
2
1
Send documentation comments to mdsfeedback-doc@cisco.com.
1-11
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Power Supplies
Table 1-2 describes the LEDs for the Cisco MDS 9513 Director power supplies.
Ta b l e 1-2 LEDs for the Cisco MDS 9513 Director Power Supplies
LED Status Description
Input 1 OK Green AC input at greater than 85 V is good and power
supply is functioning normally if two single 110 V
or one single 220 V are connected.
Off Power supply is turned off or power is not
connected.
Input 2 OK Green AC input at greater than 85 V is good and power
supply is functioning normally if two single 110 V
or one single 220 V are connected.
Off Power supply is turned off or power is not
connected.
INPUT 1 = 220VAC Green AC input is good at greater than 168 V and power
supply should function normally.
Off AC input is 163 V or less or power is not
connected.
INPUT 2 = 220VAC Green AC input is good at greater than 168 V and power
supply should function normally.
Off AC input is 163 V or less or power is not
connected.
FAN OK Green Power supply fans are operating properly.
Off Fan is not operating or power supply is off.
OUTPUT FAIL Red Power supply is not in a stable state. If this
indication continues after initial power on, check
that all connections are secure, including the
system fan tray.
Off Normal operation or power supply is turned off.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-12
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Power Supplies
Cisco MDS 9509 Power Supplies
The Cisco MDS 9509 Director supports the following types of power supplies:
4000-W AC power supply (AC input and DC output)
The 4000-W AC power supply has a permanently attached power cable, and it requires 220-VAC
input. (See Figure 1-7.)
3000-W AC power supply (AC input)
The 3000-W AC power supply requires 220 VAC to deliver 3000 W of power. If powered with
110 VAC, it delivers only 1400 W. (See Figure 1-8.)
2500-W AC power supply (AC input and DC output)
The 2500-W AC power supply requires 220 VAC to deliver 2500 W of power. If powered with 110
VAC, it delivers only 1300 W. (See Figure 1-9.)
2500-W DC power supply (DC input and DC output)
The 2500-W DC power supply requires positive, negative, and ground wires. (See Figure 1-10).
Figure 1-7 4000-W AC Power Supply for the Cisco MDS 9509 Director
1AC power connection 4Power supply switch
2Power supply LEDs 5Permanent power cable
3Captive screws
Send documentation comments to mdsfeedback-doc@cisco.com.
1-13
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Power Supplies
Figure 1-8 3000-W AC Power Supply for the Cisco MDS 9509 Director
1AC power connection 4Power supply LEDs
2Power cable 5Captive screws
3Power supply switch
144986
1
2
3
4
5 5
Send documentation comments to mdsfeedback-doc@cisco.com.
1-14
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Power Supplies
Figure 1-9 2500-W AC Power Supply for the Cisco MDS 9509 Director
Figure 1-10 2500-W DC Power Supply for the Cisco MDS 9509 Director
1AC power connection 4Captive screws
2Cable retention device 5Power supply LEDs
3Power supply switch
1Terminal block cover 4Power supply switch
2Power supply LEDs 5Terminal block
3Captive screw
99360
INPUT
OK
FAN
OK
OUTPUT
FAIL
I
0
1
23
4
5
Send documentation comments to mdsfeedback-doc@cisco.com.
1-15
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Power Supplies
Cisco MDS 9506 Power Supplies
The Cisco MDS 9506 Director supports the following types of power supplies:
1900-W AC power supply (AC input and DC output)
1900-W DC power supply (DC input and DC output)
Power is supplied to the Cisco MDS 9506 power supplies though PEMs in the front of the chassis. The
AC power requires an AC PEM, and the DC power requires a DC PEM.
The 1900-W AC and DC power supplies are similar in appearance (see Figure 1-11), except for the label
that indicates whether the power supply is AC or DC.
Figure 1-11 Cisco MDS 9506 Power Supply (1900-W AC or DC)
Table 1-3 describes the power supply LEDs for the Cisco MDS 9509 and 9506 Directors.
1Power supply LEDs 2Captive screws
INPUT OK
FAN OK
OUTPUT FAIL
94996
1
2
Ta b l e 1-3 Power Supply LEDs for the Cisco MDS 9509 and 9506 Directors
LED Status Description
Input OK Green AC input is good and power supply is functioning
normally.
Off Power supply is turned off or is not seated
properly in the chassis.
Fan OK Green Power supply fans are operating properly.
Off Fan is not operating or power supply is off.
Output Fail Red Power supply is not in a stable state. If this
indication continues after initial power on, check
that all connections are secure, including the
system fan tray.
Off Normal operation or power supply is turned off.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-16
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Fan Modules
Fan Modules
The Cisco MDS 9513 Director has a front panel fan tray with 15 fans with an abrupt stop-to-fan rotation
safety feature after power is disconnected or the fan tray is removed from the midplane. The Cisco MDS
9509 Director has a front panel fan module with nine fans and the Cisco MDS 9506 Director has a front
panel fan module with six fans.
Sensors on the supervisor module monitor the internal air temperature. If the air temperature exceeds a
preset lower-level threshold, the environmental monitor displays warning messages. If the air
temperatures exceeds a preset higher-level threshold, the switch will shut down.
If one or more fans within the module fail, the Fan Status LED turns red and the module must be
replaced. If the higher-level temperature threshold is not exceeded, the switch continues to run for five
minutes after the fan module is removed. This allows you to swap out a fan module without having to
bring the system down. For information on how to replace a fan module, see the “Removing and
Installing Fan Modules” section on page 2-68.
The fan module has one status LED that indicates the following conditions:
Green—Fan module is operating normally.
Red—One or more fans failed. Fan module should be replaced.
Off—Fan module is not properly seated in the chassis or power supply has failed.
Caution The Cisco MDS 9000 Family switches have internal temperature sensors that are capable of shutting
down the system if the temperature at different points within the chassis exceed certain safety thresholds.
To be effective, the temperature sensors require the presence of airflow; therefore, in the event a fan
module is removed from the chassis, the Cisco MDS 9000 Family switches will be shut down after five
minutes to prevent potentially undetectable overheating. However, the switches will shut down sooner if
the higher-level temperature threshold is exceeded.
The Cisco MDS 9513 Director also has crossbar module fan trays located at the back of the chassis.
There is one fan per crossbar module. There is one LED that provides operational status. Figure 1-2
shows the fan status LED on the Cisco MDS 9513 Director. To replace these fan modules, see the
“Removing and Installing Fan Modules” section on page 2-68.
Supervisor Modules
The Cisco MDS 9500 Series supports two types of supervisor modules: Supervisor-1 and Supervisor-2
modules. Both the supervisor modules provide the control and management functions for the Cisco MDS
9500 Series. The Cisco MDS 9500 Series supports two supervisor modules for redundancy. In the event
of an internal component failure, the standby supervisor module takes over, if installed. This section
discusses the following modules:
Supervisor-2 Modules, page 1-17 (DS-X9530-SF2-K9)
Supervisor-1 Modules, page 1-21 (DS-X9530-SF1-K9)
Note The internal bootflash installed on the modules are not field-replaceable units. Do not remove or replace
internal bootflash on the modules. Modifying the factory installed bootflash is not supported.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-17
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Supervisor Modules
Supervisor-2 Modules
The Cisco MDS 9500 Series offers redundant, hot-swappable, Supervisor-2 modules. (See Figure 1-12.)
Supervisor-2 modules can be used in the Cisco MDS 9509 and 9506 Directors in slots 5 and 6.
Supervisor-2 modules must be used in slots 7 and 8 of the Cisco MDS 9513 Director.
Supervisor-2 modules provide an integrated crossbar switching fabric to connect all the switching
modules when used in a Cisco MDS 9509 or 9506 Director. Single fabric configurations provide
720-Gbps full duplex speed with 80-Gbps full duplex bandwidth per switching module. Dual fabric
configurations provide 1.4-Tbps speed with 160-Gbps full duplex bandwidth per switching module. This
integrated crossbar switching fabric is disabled when a Supervisor-2 module is installed in a Cisco MDS
9513 Director. The Cisco MDS 9513 Director supports two external crossbar modules located at the rear
of the chassis that handle this function. (For more information, see the “Crossbar Modules” section on
page 1-25.)
Figure 1-12 Cisco MDS 9500 Series Supervisor-2 Module
The main functions and components of the Supervisor-2 modules are as follows:
Control and Management
Processor
Port Interfaces
LEDs on the Supervisor-2 Module
1Status, System, Active, and Power
Management LEDs1
1. See Table 1-4 on page 1-20 for status LED descriptions.
6CompactFlash LED
2Reset button 7CompactFlash eject button
3Console port 8CompactFlash slot
4MGMT 10/100/1000 Ethernet port
(with integrated Link and Activity
LEDs)
9USB ports
5COM1 serial port
144472
7 8
3
4 95
2 6
1
Send documentation comments to mdsfeedback-doc@cisco.com.
1-18
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Supervisor Modules
Control and Management
The Supervisor-2 modules provide the following control and management features:
A redundant central arbiter that provides traffic control and access fairness.
A nondisruptive restart of a single failing process on the same supervisor.
A service running on the Supervisor-2 module keeps track of the high availability policy of each
process and issues a restart when a process fails. The type of restart issued is based on the process’s
capability:
Warm or stateful (state is preserved)
Cold or stateless (state is not preserved)
A nondisruptive switchover from the active Supervisor-2 to a redundant standby without loss of
traffic.
If the Supervisor-2 module has to be restarted, then the secondary Supervisor-2 (which is
continuously monitoring the primary) takes over. Once a switchover has occurred and the failed
Supervisor-2 has been replaced or restarted, operation does not switch back to the original primary
Supervisor-2, unless it is forced to switch back or another failure occurs.
Processor
The Supervisor-2 module has a processor running at 1.4 GHz. It contains a PowerPC class processor and
offers the following memory specifications:
Port Interfaces
The Supervisor-2 module provides the following port interfaces:
RS-232 (EIA/TIA-232) console port with an RJ-45 connection that you can use to:
Configure the Cisco MDS 9500 Series from the CLI
Monitor network statistics and errors
Configure SNMP agent parameters
RS-232 COM1 port with a DB-9 connector, which can be attached to a modem.
Front panel triple speed (10/100/1000) management port with CTS function. This port is used as an
out-of-band management port. There are two LEDs associated with it. The Link LED on the left side
indicates the link status and the Activity LED on the right side blinks when there is traffic going
through this port.
Memory Bytes
DRAM 1 GB
1 internal CompactFlash card1
1. The card stores software images.
512 MB
1 external CompactFlash slot2
2. The slot is for optional cards to store additional images, and for configuration, debugging, and
syslog information.
NA3
3. NA = not applicable.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-19
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Supervisor Modules
Two USB ports provide a simple interface allowing you to connect to different devices supported by
Cisco MDS NX-OS. On the double decker connector, USB port 1 is on the lower position and port 2
is on the upper position.
Supervisor CPU subsystem based on Motorola PowerPC 7447.
Reset button that resets the Supervisor-2 without cycling the power.
External CompactFlash slot for an optional CompactFlash card provides a convenient way to boot
different images, back up the image, or store running-configuration data. The optional card can be
used for storing additional software images and configuration, debugging, and syslog information.
There is one LED that blinks when accessing this CompactFlash.
Caution Use only the CompactFlash devices that are certified for use with Cisco MDS 9000 switches and are
formatted using Cisco MDS 9000 switches. Using CompactFlash devices that are uncertified or are
formatted using other platforms may result in errors.
LEDs on the Supervisor-2 Module
The front panel on the supervisor module has the following LEDs:
Status LED
System LED
Active LED
Power Management LED
MGMT 10/100/1000 Ethernet port LEDs (at right of the port):
Link LED (on top)
Activity LED (on bottom)
CompactFlash LED for external CompactFlash card
The front panel on the Supervisor-2 module also includes a reset button (see Figure 1-13).
The LEDs on the Supervisor-2 module indicate the status of the Supervisor-2 module, power supplies,
and fan module. Table 1-4 provides more information about these LEDs.
Figure 1-13 Supervisor-2 Module LEDs
144808
Send documentation comments to mdsfeedback-doc@cisco.com.
1-20
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Supervisor Modules
Ta b l e 1-4 LEDs for the Cisco MDS 9500 Series Supervisor-2 Modules
LED Status Description
Status Green All diagnostics pass. The module is operational
(normal initialization sequence).
Orange One of the following occurs:
The module is booting or running diagnostics
(normal initialization sequence).
An over-temperature condition occurred (a minor
threshold was exceeded during environmental
monitoring).
Red One of the following occurred:
The diagnostic test failed. The module is not
operational because a fault occurred during the
initialization sequence.
An over-temperature condition occurred (a major
threshold was exceeded during environmental
monitoring).
System Green All chassis environmental monitors are reporting OK.
Orange One of the following occurred:
The power supply failed or the power supply fan
failed.
Incompatible power supplies are installed.
The redundant clock failed.
Red The temperature of the supervisor module exceeded
the major threshold.
Active Green The Supervisor-2 module is operational and active.
Orange The Supervisor-2 module is in standby mode.
Power
Management
Green Sufficient power is available for all modules.
Orange Sufficient power is not available for all modules.
MGMT
10/100/1000
Ethernet Link
LED
Green Link is up.
Off No link.
MGMT 10/100
Ethernet
Activity LED
Green Traffic is flowing through port.
Off No link or no traffic.
CompactFlash Green The external CompactFlash card is being accessed.
Off No activity.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-21
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Supervisor Modules
Supervisor-1 Modules
The Cisco MDS 9509 and 9506 Directors support up to two Supervisor-1 or Supervisor-2 modules that
can be installed in slots 5 and 6 only. The main functions and components of the Supervisor-1 modules
are as follows:
Control and Management, page 1-21
Crossbar Switching Fabric, page 1-22
Processor, page 1-22
Port Interfaces, page 1-22
LEDs on the Supervisor-1 Module, page 1-23
Note Supervisor-1 is not supported on the Cisco MDS 9513 Director.
Figure 1-14 shows a Cisco MDS 9500 Series Supervisor-1 module.
Figure 1-14 Cisco MDS 9500 Series Supervisor-1 Module
Control and Management
The supervisor modules provide the following control and management features:
A redundant central arbiter that provides traffic control and access fairness.
A nondisruptive restart of a single failing process on the same supervisor.
A kernel service running on the supervisor module keeps track of the high availability policy of each
process and issues a restart when a process fails. The type of restart issued is based on the process’s
capability:
Warm or stateful (state is preserved)
Cold or stateless (state is not preserved)
1Status, System, Active, and Pwr
Mgmt LEDs1
1. See Table 1-5 on page 1-24 for status LED descriptions.
6CompactFlash LED
2Reset button 7CompactFlash eject button
3Console port 8CompactFlash slot
4MGMT 10/100 Ethernet port (with
integrated Link and Activity LEDs)
9Asset tag
5COM1 serial port
77688
3 4 5 7 8
6
2
19
Send documentation comments to mdsfeedback-doc@cisco.com.
1-22
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Supervisor Modules
If the kernel service cannot perform a warm restart of the process, it issues a cold restart.
A nondisruptive switchover from the active supervisor to a redundant standby without loss of traffic.
If the supervisor module has to be restarted, then the secondary supervisor (which is continuously
monitoring the primary) takes over. Once a switchover has occurred and the failed supervisor has
been replaced or restarted, operation does not switch back to the original primary supervisor, unless
it is forced to switch back or another failure occurs.
Crossbar Switching Fabric
The Cisco MDS 9500 Series supervisor modules provide an integrated crossbar switching fabric to
connect all the switching modules. Single fabric configurations provide 720-Gbps full duplex speed with
80-Gbps full duplex bandwidth per switching module. Dual fabric configurations provide 1.4-Tbps
speed with 160-Gbps full duplex bandwidth per switching module.
The Cisco MDS 9500 Series supports redundant supervisor modules. Upon power up with slots 5 and 6
active, the supervisors negotiate to determine which one is active and which is the standby supervisor.
Each supervisor exchanges its own status and updates the signal quality error (SQE) status periodically.
If the active supervisor becomes disabled, the standby supervisor switches over to become the active
supervisor.
Dual supervisor modules provide dual crossbar switching fabrics for redundancy.
Processor
The Supervisor-1 module contains a Pentium III class processor. It has the following memory
specifications:
Port Interfaces
The Supervisor-1 module provides the following port interfaces:
RS-232 (EIA/TIA-232) console port with an RJ-45 connection that you can use to:
Configure the Cisco MDS 9500 Series from the CLI
Monitor network statistics and errors
Configure SNMP agent parameters
MGMT 10/100 Ethernet port with an RJ-45 connection that provides network management
capabilities.
RS-232 COM1 port with a DB-9 connector, which can be attached to a modem.
Memory Bytes
DRAM 1 GB
1 internal CompactFlash card1
1. The card stores software images.
512 MB
1 external CompactFlash slot2
2. The slot is for optional cards to store additional images, and for configuration, debugging, and
syslog information.
NA3
3. NA = not applicable.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-23
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Supervisor Modules
CompactFlash slot for an optional CompactFlash card. The optional card can be used for storing
additional software images and configuration, debugging, and syslog information.
Caution Use only the CompactFlash devices that are certified for use with Cisco MDS switches and are formatted
using Cisco MDS switches. Using CompactFlash devices that are uncertified or are formatted using
other platforms may result in errors.
LEDs on the Supervisor-1 Module
The front panel on the Supervisor-1 module has the following LEDs:
Status LED
System LED
Active LED
Power Management LED
MGMT 10/100 Ethernet port LEDs (at top of port):
Link LED (on left)
Activity LED (on right)
CompactFlash LED for external CompactFlash card
The front panel on the supervisor module also includes a reset button (see Figure 1-15).
The LEDs on the Supervisor-1 module indicate the status of the Supervisor-1 module, power supplies,
and fan module. Table 1-5 provides more information about these LEDs.
Figure 1-15 Supervisor-1 Module LEDs
144853
Send documentation comments to mdsfeedback-doc@cisco.com.
1-24
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Supervisor Modules
Ta b l e 1-5 LEDs for the Cisco MDS 9500 Series Supervisor Modules
LED Status Description
Status Green All diagnostics pass. The module is operational
(normal initialization sequence).
Orange One of the following occurs:
The module is booting or running diagnostics
(normal initialization sequence).
An over-temperature condition occurred (a minor
threshold was exceeded during environmental
monitoring).
Red One of the following occurs:
The diagnostic test failed. The module is not
operational because a fault occurred during the
initialization sequence.
An over-temperature condition occurred (a major
threshold was exceeded during environmental
monitoring).
System1
1. The System and Pwr Mgmt LEDs on a redundant supervisor module are synchronized to the
active supervisor module.
Green All chassis environmental monitors are reporting OK.
Orange One of the following occurs:
The power supply failed or the power supply fan
failed.
Incompatible power supplies are installed.
The redundant clock failed.
Red The temperature of the supervisor module exceeded
the major threshold.
Active Green The supervisor module is operational and active.
Orange The supervisor module is in standby mode.
Pwr Mgmt1Green Sufficient power is available for all modules.
Orange Sufficient power is not available for all modules.
MGMT 10/100
Ethernet Link
LED
Green Link is up.
Off No link.
MGMT 10/100
Ethernet
Activity LED
Green Traffic is flowing through port.
Off No link or no traffic.
CompactFlash Green The external CompactFlash card is being accessed.
Off No activity.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-25
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Crossbar Modules
Crossbar Modules
The Cisco MDS 9513 Director supports two external crossbar modules located at the rear of the chassis.
Each Supervisor-2 module has an associated external crossbar module for redundancy. The Supervisor-2
module in slot 7 is associated with crossbar module 1 and Supervisor-2 in slot 8 is associated with
crossbar module 2. Redundant crossbar modules act in an active-active method, where each switching
module forwards traffic across both crossbar fabrics based on the intended destination. The traffic load
is shared across both crossbar modules. Each crossbar fabric channel connects to a fabric interface ASIC
on the switching modules through serial links on the midplane. Each Supervisor-2 processor also has a
20-Gbps (40-Gbps FDX) link to each crossbar fabric for participating in management and control
protocols and for in-band diagnostics.
The LEDs on the crossbar modules indicate the status of the crossbar modules. Table 1-6 provides more
information about these LEDs.
For information regarding migrating to Generation 3 modules, see the “Migrating to Generation 3
8-Gbps Fibre Channel Switching Modules” section on page A-1.
Figure 1-16 Crossbar Module LEDs
181335
Send documentation comments to mdsfeedback-doc@cisco.com.
1-26
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Crossbar Modules
Ta b l e 1-6 LEDs for the Cisco MDS 9500 Crossbar Modules
LED Status Description
Status Green All diagnostics pass. The module is operational
(normal initialization sequence).
Orange One of the following occurs:
The module is booting or running diagnostics
(normal initialization sequence).
An over-temperature condition occurred (a minor
threshold was exceeded during environmental
monitoring).
Red One of the following occurs:
The diagnostic test failed. The module is not
operational because a fault occurred during the
initialization sequence.
An over-temperature condition occurred (a major
threshold was exceeded during environmental
monitoring).
Send documentation comments to mdsfeedback-doc@cisco.com.
1-27
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Cisco MDS 9000 Series Module Compatibility
Cisco MDS 9000 Series Module Compatibility
Table 1-7 lists the hardware modules available and the chassis compatibility associated with them.
Ta b l e 1-7 MDS 9000 Modules and Platform Compatibility Matrix
Module 9513 9509 9506 9222i 9216A 9216i 9216
Supervisor-2 module X X X
Supervisor -1 module X X
48-port 8-Gbps Fibre Channel switching module XXX
24-port 8-Gbps Fibre Channel switching module XXX
4/44-port 8-Gbps Host-Optimized Fibre Channel switching
module
XXXX
48-port 4-Gbps Fibre Channel switching module XXXXXX
24-port 4-Gbps Fibre Channel switching module XXXXXX
12-port 4-Gbps Fibre Channel switching module XXXXXX
4-port 10-Gbps Fibre Channel switching module XXXXXX
32-port 1-Gbps/2-Gbps Fibre Channel switching module X X X X X X
16-port 1-Gbps/2-Gbps Fibre Channel switching module X X X X X X
8-port Gigabit Ethernet IP Storage Services module XXXXXXX
4-port Gigabit Ethernet IP Storage Services module X X X X X X
32-port 1-Gbps/2-Gbps Fibre Channel Storage Services
Module (SSM)
XXXXXXX
32-port Fibre Channel Advanced Services Module (ASM) X X X X X
Caching Services Module (CSM) X X X X X
18-port Fibre Channel and 4-port Gigabit Ethernet IP
Services (MSM-18/4) module
XXXXXX
18-port Fibre Channel and 4-port Gigabit Ethernet IP
Services FIPS (MSFM-18/4) module
XXXXXX
14-port Fibre Channel/2-port Gigabit Ethernet
Multiprotocol Services (MPS-14/2) module
X X X X X X
Send documentation comments to mdsfeedback-doc@cisco.com.
1-28
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Port Index Availability
Port Index Availability
The Cisco MDS 9500 Multilayer Directors are designed to operate with any combination of Cisco MDS
9000 modules. However, you should be aware of the maximum port availability your chassis can support.
A port index is an internally assigned number that Cisco NX-OS uses to switch data packets within the
director or fabric switch. When the maximum number of port indexes is reached in a chassis, any
modules remaining or added to the chassis will not boot up. The number of physical ports on a Fibre
Channel module is equal to its number of port indexes. However, for Gigabit Ethernet modules (IPS-8,
IPS-4, MPS-14/2, MSM-18/4, and MSFM 18/4), one physical port is equal to four port indexes (one port
index for iSCSI and three port indexes for FC IP tunnels). Table 1-8 lists the physical ports and port
indexes (virtual ports) available per Cisco MDS 9000 module.
Using any combination of modules that include a Generation 1 module or a Supervisor-1 module limits
the port index availability to 252 on all Cisco MDS 9500 Series directors. Generation 1 modules also
require contiguous port indexes where the system assigns a block of port index numbers contiguously
starting from the first port index reserved for the slot that the module is inserted in (See Table 1-9). This
Ta b l e 1-8 Port Index Allocation
Module Physical Ports Port Indexes Allocated
48-port 8-Gbps Fibre Channel switching module 48 48
24-port 8-Gbps Fibre Channel switching module 24 24
4/44-port 8-Gbps Host-Optimized Fibre Channel
switching module
48 48
48-port 4-Gbps Fibre Channel switching module 48 48
24-port 4-Gbps Fibre Channel switching module 24 24
12-port 4-Gbps Fibre Channel switching module 12 12
4-port 10-Gbps Fibre Channel switching module 4 4
16-port 2-Gbps Fibre Channel switching module 16 161
1. All Generation 1 modules reserve port indexes on fixed boundaries with Supervisor-1. See Table 1-9.
32-port 2-Gbps Fibre Channel switching module 32 321
8-port Gigabit Ethernet IP Storage Services module 8321
4-port Gigabit Ethernet IP Storage Services module 432 (with Supervisor-1)
16 (with Supervisor-2)
32-port 2-Gbps Fibre Channel Storage Services module
(SSM)
32 321
18-port Fibre Channel and 4-port Gigabit Ethernet IP
Multiservice module (MSM-18/4)
222
2. 18 Fibre Channel ports and four Gigabit Ethernet ports.
34
18-port Fibre Channel and 4-port Gigabit Ethernet IP
Multiservice FIPS module (MSFM-18/4)
223
3. 18 Fibre Channel ports and four Gigabit Ethernet ports.
34
14-port Fibre Channel/2-port Gigabit Ethernet
Multiprotocol Services (MPS-14/2) module
164
4. 14 Fibre Channel ports and two Gigabit Ethernet ports.
32 (with Supervisor-1)
22 (with Supervisor-2)
Send documentation comments to mdsfeedback-doc@cisco.com.
1-29
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Port Index Availability
means that while there may be enough port indexes available for a Generation 1 module, the module may
not boot up because the available port indexes are not in a contiguous range or the contiguous block does
not start at the first port index for a given slot.
Example 1-1 shows a scenario with a Supervisor-1 module, where a 48-port Generation 2 module
borrowed port indexes from the first slot. Slot 1 still has 16 port indexes available, but the full 32 indexes
are no longer available (28-31 are used by the module in slot 4). This means that no Generation 1 module
except a 16-port Fibre Channel switching module can be inserted into slot 1 because some of the port
indexes for the slot are already in use.
Example 1-1 Borrowing Port Indexes from Another Slot
switch# show port index-allocation
Module index distribution:
---------------------------------------------------+
Slot | Allowed | Alloted indices info |
| range* | Total | Index values |
-------|---------|-------|-------------------------|
1 | 0- 31| - | - |
2 | 32- 63| 32 | 32-63 |
3 | 64- 95| 48 | 64-95,224-239 |
4 | 96- 127| 48 | 96-127, 240-252, 28-31 |
7 | 128- 159| 32 | 128-159 |
8 | 160- 191| 32 | 160-191 |
9 | 192- 223| 32 | 192-223 |
SU | 253-255 | 3 | 253-255 |
*Allowed range applicable only for Generation-1 modules
Using any combination of modules that include a Generation 1 module and a Supervisor-2 module
limits the port index availability to 252 on all Cisco MDS 9500 Series Directors. The Generation 1
modules can use any contiguous block of port indexes that start on the first port index reserved for any
slot in the range 0-252. (See Table 1-9.)
Using any combination of only Generation 2 with a Supervisor-2 module allows a maximum of 528 (with
an architectural limit of 1020) port indexes on all Cisco MDS 9500 Series Directors. Generation 2
modules do not need contiguous port indexes. Generation 2 modules use the available indexes in the slot
that it is installed and then borrow available indexes from the supervisors. If the module requires more
indexes, it starts borrowing available indexes from slot 1 of the chassis until it has the number of port
indexes necessary.
Note Enter the purge module CLI command to free up reserved port indexes after you remove a module.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-30
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Port Index Availability
Table 1-10 shows a valid sample configuration for maximum capacity within the port index limits. The
table lists a mixture of Generation 1 and Generation 2 modules on a Cisco MDS 9509 Director.
Table 1-11 shows a sample configuration that exceeds the port index limit. The table lists a mixture of
Generation 1 storage IPS modules and Generation 2 modules on a Cisco MDS 9509 Director. In this
example, one of the modules installed will not boot up because the number of port indexes needed has
been exceeded.
Ta b l e 1-9 Port Index Requirements
Supervisor Module Port Index Requirements
Supervisor-1 Generation 1 Indexes must be:
Contiguous
In the range assigned to the given slot
Start with the lowest value assigned to
that slot
Maximum 252 assignable port indexes
available,
Generation 2 Indexes can be any available number in the
range 0–252.
Supervisor-2 Generation 1 Indexes must be contiguous, but can be any
available contiguous block in the range
0–252.
Generation 2 Indexes can be any available number in the
range 0–1020 if all modules are Generation
2 modules. Otherwise, indexes can be any
available number in the range 0–252.
Ta b l e 1-10 Sample Chassis Configuration on a Cisco MDS 9509 Director (Valid)
Slot No. Modules in Cisco MDS 9509 Director Generation
Physical
Ports
Port
Indexes
112-port 4-Gbps Fibre Channel switching module 112 12
248-port 4-Gbps Fibre Channel switching module 248 48
348-port 4-Gbps Fibre Channel switching module 248 48
448-port 4-Gbps Fibre Channel switching module 248 48
5Supervisor-1 1
6Supervisor-1 1
748-port 4-Gbps Fibre Channel switching module 248 48
848-port 4-Gbps Fibre Channel switching module 248 48
9
Total s 252 252
Send documentation comments to mdsfeedback-doc@cisco.com.
1-31
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Port Index Availability
Using any combination of modules that include a Generation 1 module and a Supervisor-2 module limits
the port index availability to 252 on all Cisco MDS 9500 Series Directors. But the Generation 1 modules
can use any contiguous block of port indexes in the range 0–252 (See Table 1-9).
Using any combination of only Generation 2 with a Supervisor-2 module allows a maximum of 528 (with
an architectural limit of 1020) port indexes on all Cisco MDS 9500 Series Directors. Generation 2
modules do not need contiguous port indexes. Generation 2 modules will use the available ports in the
slot that it is installed and then borrow available ports from the supervisors, and then restart at slot 1 of
the chassis until it has the number of port indexes necessary.
Table 1-12 shows a valid sample configuration for maximum capacity within the port index limits. The
table only lists Generation 2 modules in a Cisco MDS 9513 Director.
Ta b l e 1-11 Maximum Chassis Configuration on a Cisco MDS 9509 Director (Exceeded)
Slot No. Modules in Cisco MDS 9509 Director Generation
Physical
Ports
Port
Indexes
118-port Fibre Channel and 4-port Gigabit Ethernet IP
Multiservice module (MSM-18/4)
222 34
214-port Fibre Channel/2-port Gigabit Ethernet
Multiprotocol Services (MPS-14/2) module
116 22
38-port Gigabit Ethernet IP Storage Services module 1832
44-port Gigabit Ethernet IP Storage Services module 1416
548-port 4-Gbps Fibre Channel switching module 248 48
6Supervisor-1 1
7Supervisor-1 1
848-port 4-Gbps Fibre Channel switching module 248 48
948-port 4-Gbps Fibre Channel switching module 248 48
10 48-port 4-Gbps Fibre Channel switching module 248 48
Total s 240 296
Ta b l e 1-12 Maximum Chassis Configuration on a Cisco MDS 9513 Director (Valid)
Slot No. Modules in Cisco MDS 9513 Director Generation
Physical
Ports
Port
Indexes
148-port 4-Gbps Fibre Channel switching module 248 48
248-port 4-Gbps Fibre Channel switching module 248 48
348-port 4-Gbps Fibre Channel switching module 248 48
448-port 4-Gbps Fibre Channel switching module 248 48
548-port 4-Gbps Fibre Channel switching module 248 48
648-port 4-Gbps Fibre Channel switching module 248 48
7Supervisor-2 2
8Supervisor-2 2
948-port 4-Gbps Fibre Channel switching module 248 48
10 48-port 4-Gbps Fibre Channel switching module 248 48
Send documentation comments to mdsfeedback-doc@cisco.com.
1-32
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Switching Modules
Switching Modules
The Cisco MDS 9500 Series supports the following hot-swappable Fibre Channel switching modules:
Generation 3 modules
48-port 8-Gbps Fibre Channel Switching Module
24-port 8-Gbps Fibre Channel Switching Module
4/44-port 8-Gbps Host-Optimized Fibre Channel Switching Module
Generation 2 modules
48-Port 4-Gbps Fibre Channel Switching Module
24-port 4-Gbps Fibre Channel Switching Module
12-port 4-Gbps Fibre Channel Switching Module
4-port 10-Gbps Fibre Channel Switching Module
Generation 1 modules
32-Port 2-Gbps Fibre Channel Switching Module
16-Port 2-Gbps Fibre Channel Switching Module
The Cisco MDS 9500 Series supports up to eleven hot-swappable switching modules. By combining
different switching modules in a single, modular chassis, you can design cost and performance optimized
storage networks in a wide range of application environments.
The Fibre Channel switching modules provide system-wide power management and autonegotiation,
which allows ports to negotiate for speed at the other end of the link. Each module has temperature
sensors and an EEPROM that stores serial number and model number information.
The Fibre Channel port interfaces support hot-swappable Fibre Channel SFP and SFP+ transceivers,
which can be short wavelength (SWL) or long wavelength (LWL). The port interfaces also support
coarse wavelength-division multiplexing (CWDM) and dense wavelength-division multiplexing
(DWDM) SFP transceivers, which can be used for extended long wavelength (ELWL) transmission or
for coarse wavelength-division multiplexing (CWDM) and dense wavelength-division multiplexing
(DWDM). See the “Supported Transceivers” section on page 1-55.
Note The internal bootflash installed on the modules are not field-replaceable units. Do not remove or replace
internal bootflash on the modules. Modifying the factory-installed bootflash is not supported.
For configuration information about the modules, see the Cisco MDS 9000 Family CLI Configuration
Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide.
11 48-port 4-Gbps Fibre Channel switching module 248 48
12 48-port 4-Gbps Fibre Channel switching module 248 48
13 48-port 4-Gbps Fibre Channel switching module 248 48
Total s 528 528
Table 1-12 Maximum Chassis Configuration on a Cisco MDS 9513 Director (Valid) (continued)
Slot No. Modules in Cisco MDS 9513 Director Generation
Physical
Ports
Port
Indexes
Send documentation comments to mdsfeedback-doc@cisco.com.
1-33
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Switching Modules
48-port 8-Gbps Fibre Channel Switching Module
The 48-Port 8-Gbps Fibre Channel switching module offers 48 autosensing 1-, 2-, 4- and 8-Gbps Fibre
Channel ports and can be used in the Cisco MDS 9500 Series Switches. The 48-port switching module
can be configured in one of two operational modes: shared bandwidth mode (default) and dedicated
bandwidth mode.
Figure 1-17 shows a 48-port 8-Gbps Fibre Channel switching module. The front panel connectors
support standard modular SFP and SFP+ transceivers and the speed detection is autosensing.
Figure 1-17 48-Port 8-Gbps Fibre Channel Switching Module
24-port 8-Gbps Fibre Channel Switching Module
The 24-Port 8-Gbps Fibre Channel switching module offers 24 autosensing 1-, 2-, 4- and 8-Gbps Fibre
Channel ports and can be used in the Cisco MDS 9500 Series Switches. The 24-port switching module
can be configured in one of two operational modes: shared bandwidth mode (default) and dedicated
bandwidth mode.
Figure 1-18 shows a 24-port 8-Gbps Fibre Channel switching module. The front panel connectors
support standard modular SFP and SFP+ transceivers and the speed detection is autosensing.
Figure 1-18 24-Port 8-Gbps Fibre Channel Switching Module
4/44-port 8-Gbps Host-Optimized Fibre Channel Switching Module
The 4/44-port 8-Gbps Host-Optimized Fibre Channel switching module offers 48 autosensing 1-, 2-, 4-
and 8-Gbps Fibre Channel ports and can be used in any of the Cisco MDS 9500 Series chassis and in the
Cisco MDS 9222i Switches. The 48-port switching module can be configured in one of two operational
modes: shared bandwidth mode (default) and dedicated bandwidth mode.
Figure 1-19 shows a 4/44-port 8-Gbps Host-Optimized Fibre Channel switching module. The front panel
connectors support standard modular SFP and SFP+ transceivers and the speed detection is autosensing.
188655
188656
Send documentation comments to mdsfeedback-doc@cisco.com.
1-34
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Switching Modules
Figure 1-19 4/44-port 8-Gbps Host-Optimized Fibre Channel Switching Module
48-Port 4-Gbps Fibre Channel Switching Module
The 48-port 4-Gbps Fibre Channel switching module offers 48 autosensing 1-, 2-, and 4-Gbps Fibre
Channel ports and can be used in any of the Cisco MDS 9500 Series chassis and in the Cisco MDS 9216i
and 9216A Switches. The 48-port switching module can be configured in one of two operational modes:
shared bandwidth mode (default) and dedicated bandwidth mode.
Figure 1-20 shows a 48-port 4-Gbps Fibre Channel switching module. The front panel connectors
support standard modular SFP and the speed detection is autosensing.
Figure 1-20 48-Port 4-Gbps Fibre Channel Switching Module
Figure 1-21 shows the port numbering and LEDs on the 48-port 4-Gbps Fibre Channel switching
module.
Figure 1-21 48-Port 4-Gbps Fibre Channel Switching Module LEDs
188657
144474
1Status LED 3Fibre Channel ports
2Link LEDs
144809
1
23
Send documentation comments to mdsfeedback-doc@cisco.com.
1-35
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Switching Modules
24-port 4-Gbps Fibre Channel Switching Module
The 24-port 4-Gbps Fibre Channel switching module offers 24 autosensing 1-, 2-, and 4-Gbps Fibre
Channel ports and can be used in any of the Cisco MDS 9500 Series chassis and in the Cisco MDS 9216i
and 9216A Switches. The 24-port switching module can be configured in one of two operational modes:
shared bandwidth mode (default) and dedicated bandwidth mode.
Figure 1-22 shows a 24-port 4-Gbps Fibre Channel switching module. The front panel connectors
support standard modular SFP and the speed detection is autosensing.
Figure 1-22 24-Port 4-Gbps Fibre Channel Switching Module
12-port 4-Gbps Fibre Channel Switching Module
The 12-port 4-Gbps Fibre Channel switching module can be used in any of the Cisco MDS 9500 Series
chassis and in the Cisco MDS 9216i and 9216A Switches. The 12-port 4-Gbps switching module is a
full rate mode module providing 12 SPF-based Fibre Channel interfaces. Each interface is capable of
supporting full line rate operation at 4-Gbps interface speed. The module delivers a sustained data rate
of up to 4 Gbps in each direction, on all ports simultaneously, and up to 96 Gbps of continuous, aggregate
bandwidth when attached to high-performance servers and storage subsystems.
Figure 1-23 shows a 12-port 4-Gbps Fibre Channel switching module. The front panel connectors
support standard modular SFP and the speed detection is autosensing.
Figure 1-23 12-Port 4-Gbps Fibre Channel Switching Module
1Status LED 3Fibre Channel ports
2Link LEDs 4Port group
144471
2
34
1
1Status LED 3Link LEDs
2Fibre Channel ports
144470
3
2
1
Send documentation comments to mdsfeedback-doc@cisco.com.
1-36
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Switching Modules
4-port 10-Gbps Fibre Channel Switching Module
The 4-port 10-Gbps Fibre Channel switching module offers four dedicated bandwidth Fibre Channel
ports running at 10 Gbps with no oversubscription. This module can be used in any of the Cisco MDS
9500 Series chassis and in the Cisco MDS 9216i and 9216A Switches. The module delivers a sustained
data rate of up to 10 Gbps in each direction, on all ports simultaneously, and up to 80 Gbps of continuous,
aggregate bandwidth.
Figure 1-24 shows a 4-port 10-Gbps switching module. The front panel connectors support standard
modular X2 interfaces and the speed is fixed at 10 Gbps.
Figure 1-24 4-Port 10-Gbps Fibre Channel Switching Module
1Status LED 3Link LED
2X2 port interfaces
144473
2
3
1
Send documentation comments to mdsfeedback-doc@cisco.com.
1-37
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Switching Modules
LEDs on the Generation 2 Switching Modules
Table 1-13 describes the LEDs for the 48-port, 24-port, and 12-port 4-Gbps Fibre Channel switching
modules and the 4-port 10-Gbps Fibre Channel switching module.
32-Port 2-Gbps Fibre Channel Switching Module
The 32-port 2-Gbps Fibre Channel switching module can be used to allocate bandwidth optimally. The
module is organized into eight four-port groups. Only the first port in each four-port group can be an
ISL. If the first port is an ISL, the other three ports in the group are disabled. The four ports within a port
group share a single internal channel resulting in a subscription ratio of approximately 3.2 to 1. The
32-port 2-Gbps switching module provides more ports at a lower price per port. Figure 1-25 shows a
32-port switching module.
Ta b l e 1-13 LEDs for the Cisco MDS 9000 Family Generation 2 Fibre Channel Switching Modules
LED Status Description
Status Green All diagnostics pass. The module is operational
(normal initialization sequence).
Orange One of the following occurs or occurred:
The module is booting or running diagnostics
(normal initialization sequence).
The inlet air temperature of the system has
exceeded the maximum system operating
temperature limit (a minor environmental
warning). To ensure maximum product life, you
should immediately correct the environmental
temperature and restore the system to normal
operation.
Red One of the following occurs or occurred:
The diagnostic test failed. The module is not
operational because a fault occurred during the
initialization sequence.
The inlet air temperature of the system has
exceeded the safe operating temperature limits of
the card (a major environmental warning). The
card has been shut down to prevent permanent
damage.
Link Solid green Link is up.
Intermittent
flashing green
Link is up (traffic on port).
Solid yellow Link is disabled by software.
Flashing
yellow
A fault condition exists.
Off No link.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-38
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Switching Modules
Tip For a full 2-Gbps bandwidth between two hosts, connect one host to the first port group and the second
host to the second port group.
Figure 1-25 Cisco MDS 9000 Family 32-Port 2-Gbps Switching Module
16-Port 2-Gbps Fibre Channel Switching Module
The 16-port 2-Gbps switching module supports a sustained data rate of up to 2-Gbps in each direction,
on all ports simultaneously. The autosensing 2-Gbps ports of the 16-port Fibre Channel switching
module deliver up to 64-Gbps of continuous, aggregate bandwidth when attached to high-performance
servers and storage subsystems. Figure 1-26 shows a 16-port 2-Gbps switching module.
Figure 1-26 Cisco MDS 9000 Family 16-Port 2-Gbps Switching Module
1Status LED 3Link LEDs (under ports, on left) and
Speed LEDs (under ports, on right)
21-Gbps/2-Gbps Fibre Channel port
group
4Asset tag
91673
2
1 4
3
17 20
4
DS-X9032
5
21 24
89
25 28
12 13
29 32
16
1Status LED 3Link LEDs (under ports, on left) and
Speed LEDs (under ports, on right)
21-Gbps/2-Gbps Fibre Channel
ports
4Asset tag
91672
4
3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
2
1
Send documentation comments to mdsfeedback-doc@cisco.com.
1-39
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Switching Modules
Switching Module Features
Each switching module draws its power from the 42 V supplied on the backplane with local DC/DC
power converters and regulators.
The control processor on the switching module provides power-on, offline, and online diagnostics. The
control processor can be used for configuring devices on the switching module and to gather statistical
data from each port.
The control processor can determine which slot it is plugged into, and it can monitor its DC/DC power
source and temperature. The control processor signals the supervisor module and displays an alarm on
its front panel when a problem is detected.
The front panel on the switching module provides basic status information, such as power-on, self-test
running, self-test passed, alarm, and ready.
The binary image for the switching module is downloaded from the supervisor module. Prior to the
image download, the control processor on the switching module runs from code stored on its local
CompactFlash card.
Note Routine software downloads are not required.
The supervisor module can force a reset on the switching module and controls whether power is applied
to the switching module.
If a single component or a set of components on the switching module fails, this does not disable other
switching modules if that is the only failure in the system.
Each switching module has a hardware watchdog timer for detecting most component failures. This
watchdog resets the card if is not serviced periodically.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-40
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Switching Modules
LEDs on the Generation 1 Switching Module
Table 1-14 describes the LEDs for the 16-port and 32-port switching modules.
The Fibre Channel switching modules provide autoconfiguring Fibre Channel ports that support Fibre
Channel speeds of 1.0625 Gbps and 2.125 Gbps. For more information about supported port types, see
the Cisco MDS 9000 Family CLI Configuration Guide.
Ta b l e 1-14 LEDs for the Cisco MDS 9000 Family Generation 1 Fibre Channel Switching Modules
LED Status Description
Status Green All diagnostics pass. The module is operational
(normal initialization sequence).
Orange One of the following occurs or occurred:
The module is booting or running diagnostics
(normal initialization sequence).
The inlet air temperature of the system has
exceeded the maximum system operating
temperature limit (a minor environmental
warning). To ensure maximum product life, you
should immediately correct the environmental
temperature and restore the system to normal
operation.
Red One of the following occurs or occurred:
The diagnostic test failed. The module is not
operational because a fault occurred during the
initialization sequence.
The inlet air temperature of the system has
exceeded the safe operating temperature limits of
the card (a major environmental warning). The
card has been shut down to prevent permanent
damage.
Speed On 2-Gbps mode.
Off 1-Gbps mode.
Steady
flashing green
Link is up (beacon used to identify port).1
1. The flashing green light turns on automatically when an external loopback is detected that causes
the interfaces to be isolated. The flashing green light overrides the beacon mode configuration.
The state of the LED is restored to reflect the beacon mode configuration after the external
loopback is removed.
Link Solid green Link is up.
Intermittent
flashing green
Link is up (traffic on port).
Solid yellow Link is disabled by software.
Flashing
yellow
A fault condition exists.
Off No link.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-41
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
Services Modules
The Cisco MDS 9500 Series supports the following hot-swappable Generation 1 services modules:
18/4-Port Multiservice Module, page 1-41
18/4-Port Multiservice Federal Information Processing Standards Module, page 1-42
14/2-Port Multiprotocol Services Module, page 1-44
IP Storage Services Modules, page 1-46
32-Port Fibre Channel Advanced Services Module, page 1-48
32-Port Fibre Channel Storage Services Module, page 1-50
Caching Services Module, page 1-52
Note The internal bootflash installed on the modules are not field-replaceable units. Do not remove or replace
internal bootflash on the modules. Modifying the factory installed bootflash is not supported.
18/4-Port Multiservice Module
The Cisco MDS 9000 Family 18/4-port Multiservice (MSM-18/4) module provides 18 autosensing 1-,
2-, and 4-Gbps Fibre Channel ports and four Gigabit Ethernet IP services ports. The MSM-18/4 module
provides multiprotocol capabilities such as Fibre Channel, Fibre Channel over IP (FCIP), Small
Computer System Interface over IP (iSCSI), IBM Fiber Connectivity (FICON), and FICON Control Unit
Port (CUP) management.
The MSM-18/4 module provides18 4-Gbps Fibre Channel interfaces for high-performance SAN and
mainframe connectivity and four Gigabit Ethernet ports for FCIP and iSCSI storage services. Individual
ports can be configured with hot-swappable shortwave, longwave, extended-reach, coarse
wavelength-division multiplexing (CWDM) or dense wavelength-division multiplexing (DWDM) Small
Form-Factor Pluggables (SFPs) for connectivity up to 125 miles (200 km).
The MSM-18/4 module can minimize latency for disk and tape through FCIP write acceleration and
FCIP tape write and read acceleration. The MSM-18/4 module provides up to 16 virtual Inter-Switch
Link (ISL) connections on the four 1-Gigabit Ethernet ports through tunneling, and provides up to 4095
buffer-to-buffer credits that can be assigned to a single Fibre Channel port.
The MSM-18/4 supports hardware-based encryption and it is required to run the Storage Media
Encryption (SME) which, is a part of the Cisco NX-OS. For more information on SME, see the Cisco
MDS Storage Media Encryption Guide.
The MSM-18/4 supports SAN extension over IP and is compatible with current SAN extension products,
such as MPS-14/2, 9216i, and IPS. The MSM-18/4 provides an integrated next generation 4-Gbps FC
platform for SAN extension. The MSM-18/4 module supports Internet Protocol version 6 (IPv6) as
mandated by the U.S. Department of Defense (DoD), Japan, and China. The IPv6 support is provided
for FCIP, iSCSI, and management traffic routed in-band and out-of-band.
The MSM-18/4 provides intelligent diagnostics, protocol decoding, and network analysis tools with the
integrated Call Home capability.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-42
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
18/4-Port Multiservice Federal Information Processing Standards Module
The Cisco MDS 9000 Family 18/4-port Multiservice FIPS (MSFM-18/4) module is a FIPS 140-2 Level
3-compliant version of the MSM-18/4 module. The MSFM-18/4 module is identical to the MSM-18/4
module in form and function, with the exception of an opaque potting material encapsulating the
cryptographic boundary of the MSFM-18/4 module to prevent unauthorized access and tampering.
Note Cisco MDS 9500 Series switches running Cisco MDS SAN-OS Release 3.2(1) or later, or NX-OS
Release 4.1(1b) support the MSM-18/4 and the MSFM-18/4 module.
Figure 1-27 shows the MSM-18/4 module.
Figure 1-27 18/4-Port Multiservice Module
184706
12
43
1Status LED 3Gigabit Ethernet ports
21-Gbps/2-Gbps/4-Gbps Fibre Channel ports 4Link LEDs
Send documentation comments to mdsfeedback-doc@cisco.com.
1-43
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
LEDs on the 18/4-Port Multiservice Module
Table 1-15 describes the LEDs for the 18/4-port Multiservice module.
Ta b l e 1-15 LEDs for the Cisco MDS 9000 Family 18/4-Port Multiservice Modules
LED Status Description
Status Green All diagnostics pass. The module is operational (normal
initialization sequence).
Orange One of the following occurs or occurred:
The module is booting or running diagnostics (normal
initialization sequence).
The inlet air temperature of the system exceeded the
maximum system operating temperature limit (a minor
environmental warning). To ensure maximum product
life, you should immediately correct the environmental
temperature and restore the system to normal operation.
Red One of the following occurred:
The diagnostic test failed. The module is not operational
because a fault occurred during the initialization
sequence.
The inlet air temperature of the system exceeded the safe
operating temperature limits of the card (a major
environmental warning). The card shut down to prevent
permanent damage.
Link Solid
green
Link is up.
Solid
yellow
Link is disabled by software.
Flashing
yellow
A fault condition exists.
Off No link.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-44
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
14/2-Port Multiprotocol Services Module
The 14/2-port Multiprotocol Services (MPS-14/2) module provides 14 2-Gbps Fibre Channel
autosensing ports and two 1-Gigabit Ethernet ports for iSCSI and FCIP over Gigabit Ethernet. The
MPS-14/2 module supports the intelligent features available on other modules, including VSANs,
security, and traffic management.
The 14 2-Gbps autosensing Fibre Channel ports (labeled 1 through 14) are best used for applications
requiring high bandwidth; for example, Inter-Switch Link (ISL) connections between switches and
high-performance host or storage controllers. Each Fibre Channel port supports a sustained data rate of
up to 2 Gbps in each direction.
The Cisco 9513 supports up to seven MPS-14/2 modules. The Cisco MDS 9509 supports up to seven
MPS-14/2 modules. The Cisco MDS 9506 supports up to four MPS-14/2 modules. The two Gigabit
Ethernet ports (labeled 1 and 2) provide 1-Gbps throughput for IP services, including iSCSI and FCIP
over Gigabit Ethernet. The MPS-14/2 also supports hardware-based encryption and compression for
these Gigabit Ethernet ports. This hardware-based encryption handles the computationally intensive
IPsec feature for IP services.
The MPS-14/2 modules support FCIP compression to maximize the effective WAN bandwidth of SAN
extension solutions. It achieves up to a 30 to 1 compression ratio, with typical ratios of 2 to 1 over a wide
variety of data sources. With the addition of hardware-based compression, the MPS-14/2 module is able
to provide optimal levels of compressed throughput for implementations across low-bandwidth to
high-bandwidth links.
The Gigabit Ethernet ports on the MPS-14/2 module support the iSCSI protocol, the FCIP protocol, or
both protocols simultaneously. For information about configuring the ports, see the Cisco MDS 9000
Family CLI Configuration Guide or the Cisco MDS Family Fabric Manager Configuration Guide.
The Fibre Channel port interfaces support hot-swappable Fibre Channel SFP transceivers, which can be
short wavelength (SWL) for connectivity up to 1640 feet (500 meters), or long wavelength (LWL) for
connectivity up to 6.2 miles (10 km). All Fibre Channel interfaces are autosensing 1-Gbps or 2-Gbps
compatible. The Fibre Channel interfaces also support coarse wavelength-division multiplexing
(CWDM) SFP transceivers, which can be used for extended long wavelength (ELWL) transmission or
for CWDM. See the “Supported Transceivers” section on page 1-55.
Note Cisco MDS 9500 Series switches running Cisco MDS SAN-OS Release 2.x, 3.x, or NX-OS Release
4.1(1b) support the MPS-14/2 module.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-45
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
Figure 1-28 shows an MPS-14/2 module.
Figure 1-28 Cisco MDS 9000 Family MPS-14/2 Module
LEDs on the MPS-14/2 Module
Table 1-16 describes the LEDs for the MPS-14/2 modules.
1Status LED 4Gigabit Ethernet ports
21-Gbps/2-Gbps Fibre Channel ports 5Link LEDs
3Link LEDs (under ports, on left) and Speed LEDs
(under the ports, on the right)
6Asset tag
—SPEED LINK—
LINK-
—SPEEDLINK—
STATUS
1 56789
LINK— —SPEED
10 11 12 13 14234
12
LINK-
GIGABIT E THERNET
116889
1 6
2 4
3 5
Ta b l e 1-16 LEDs for the Cisco MDS 9000 Family MPS-14/2 Modules
LED Status Description
Status Green All diagnostics pass. The module is operational (normal initialization sequence).
Orange One of the following occurs or occurred:
The module is booting or running diagnostics (normal initialization sequence).
The inlet air temperature of the system exceeded the maximum system
operating temperature limit (a minor environmental warning). To ensure
maximum product life, you should immediately correct the environmental
temperature and restore the system to normal operation.
Red One of the following occurred:
The diagnostic test failed. The module is not operational because a fault
occurred during the initialization sequence.
The inlet air temperature of the system exceeded the safe operating temperature
limits of the card (a major environmental warning). The card shut down to
prevent permanent damage.
Speed On 2-Gbps mode.
Off 1-Gbps mode.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-46
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
IP Storage Services Modules
The 4-port and 8-port IP Storage services (IPS-4 and IPS-8) modules provide four or eight 1-Gigabit
Ethernet ports for iSCSI as well as FCIP over Gigabit Ethernet, and they support the intelligent features
available on other modules, including VSANs, security, and traffic management.
The IPS module ports can be configured to support the iSCSI protocol, the FCIP protocol, or both
protocols simultaneously. For information about configuring the ports, see the Cisco MDS 9000 Family
CLI Configuration Guide or the Cisco MDS Family Fabric Manager Configuration Guide.
The Fibre Channel port interfaces support hot-swappable Gigabit Ethernet SFP transceivers, which can
be short wavelength (SWL) for connectivity up to 1640 feet (500 meters), or long wavelength (LWL) for
connectivity up to 6.2 miles (10 km). The port interfaces also support coarse wavelength-division
multiplexing (CWDM) SFP transceivers, which can be used for extended long wavelength (ELWL)
transmission or for CWDM. See the “Supported Transceivers” section on page 1-55.
Figure 1-29 shows an IPS-8 services module.
Figure 1-29 Cisco MDS 9000 Family IPS-8 Services Module
Link Solid
green
Link is up.
Flashing
green
Link is up (beacon used to identify port).
Solid
yellow
Link is disabled by software.
Flashing
yellow
A fault condition exists.
Off No link.
Table 1-16 LEDs for the Cisco MDS 9000 Family MPS-14/2 Modules (continued)
LED Status Description
1Status LED 3Link LEDs
2Gigabit Ethernet ports 4Asset tag
91694
2
14
3
Send documentation comments to mdsfeedback-doc@cisco.com.
1-47
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
Figure 1-30 shows the IPS-4 services module.
Figure 1-30 Cisco MDS 9000 Family IPS-4 Services Module
LEDs on IP Storage Services Modules
Table 1-17 describes the LEDs for the IPS services modules.
1Status LED 3Link LEDs
2Gigabit Ethernet ports 4Asset tag
113161
LINK LINK LINK LINK
1234
14
3
2
Ta b l e 1-17 LEDs for the Cisco MDS 9000 Family IPS Module
LED Status Description
Status Green All diagnostics pass. The module is operational (normal initialization sequence).
Orange One of the following occurs or occurred:
The module is booting or running diagnostics (normal initialization
sequence).
The inlet air temperature of the system exceeded the maximum system
operating temperature limit (a minor environmental warning). To ensure
maximum product life, you should immediately correct the environmental
temperature and restore the system to normal operation.
Red One of the following occurred:
The diagnostic test failed. The module is not operational because a fault
occurred during the initialization sequence.
The inlet air temperature of the system exceeded the safe operating
temperature limits of the card (a major environmental warning). The card shut
down to prevent permanent damage.
Link Solid
green
Link is up.
Flashing
green
Link is up (beacon used to identify port).
Solid
yellow
Link is disabled by software.
Flashing
yellow
A fault condition exists.
Off No link.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-48
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
32-Port Fibre Channel Advanced Services Module
The Cisco MDS 9000 Family 32-port Fibre Channel Advanced Services Module (ASM) enables pooling
of heterogeneous storage for increased storage utilization, simplified storage management, and reduced
total cost of storage ownership. The ASM incorporates all the capabilities of the Cisco MDS 9000
DS-X9032 Fibre Channel switching module and also provides scalable, in-band storage virtualization
services. The module makes it possible to allocate bandwidth optimally.
The Fibre Channel port interfaces support hot-swappable Fibre Channel SFP transceivers, which can be
short wavelength (SWL) for connectivity up to 500 meters (1640 feet), or long wavelength (LWL) for
connectivity up to 10 km (6.2 miles). All interfaces are autosensing 1-Gbps or 2-Gbps compatible. The
port interfaces also support coarse wavelength-division multiplexing (CWDM) SFP transceivers, which
can be used for extended long wavelength (ELWL) transmission or for CWDM. See the “Supported
Transceivers” section on page 1-55.
Note Cisco MDS 9509 and 9506 Directors running Cisco MDS SAN-OS Release 1.2(2a) to Release 2.1(x)
support the Fibre Channel ASM. The Cisco MDS 9513 Director does not support the ASM.
Figure 1-31 shows the Fibre Channel ASM.
Figure 1-31 Fibre Channel ASM
Each module draws power from the 42 V supplied on the backplane with local DC/DC power converters
and regulators.
The control processor on the module provides power-on, offline, and online diagnostics. The control
processor can be used to configure devices on the switching module and to gather statistical data from
each port.
The control processor monitors the DC/DC power source and temperature. The control processor signals
the supervisor module and displays an alarm on its front panel when a problem is detected.
The front panel on the services module provides basic status information, such as power-on, self-test
running, self-test passed, alarm, and ready.
The binary image for the services module is downloaded from the supervisor module. Prior to the image
download, the control processor on the switching module runs from code stored on its local
CompactFlash card. The image for an ASM can be specified using the ASM-SFN boot variable. For
details on how to specify the ASM-SFN boot variable, see the Cisco MDS 9000 Family CLI Configuration
Guide.
1Status LED 3Link and Speed LEDs
21-Gbps/2-Gbps Fibre Channel port
group
4Asset tag
94298
2
1 43
17 20
45
21 24
89
25 28
12 13
29 32
16
DS-X9032
Send documentation comments to mdsfeedback-doc@cisco.com.
1-49
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
Note Software downloads are only necessary when a revision of the code is needed.
The supervisor module can force a reset on the services module and controls whether power is applied
to the switching module.
If a single component or a set of components on the switching module fails, this failure does not disable
another switching module if that is the only failure in the system.
Each ASM has a hardware watchdog timer to detect most component failures. The watchdog timer resets
the card if it is not serviced periodically.
LEDs on the Fibre Channel Advanced Services Modules
Table 1-18 describes the LEDs for the ASM.
Ta b l e 1-18 LEDs for the Cisco MDS 9000 Family Fibre Channel ASMs
LED Status Description
Status Green All diagnostics pass and the module is operational (normal
initialization sequence).
Orange One of the following occurs or occurred:
The module is booting or running diagnostics (normal
initialization sequence).
The inlet air temperature of the system exceeded the
maximum system operating temperature limit (a minor
environmental warning). To ensure maximum product life,
you should immediately correct the environmental
temperature and restore the system to normal operation.
Red One of the following occurred:
The diagnostic test failed. The module is not operational
because a fault occurred during the initialization sequence.
The inlet air temperature of the system exceeded the safe
operating temperature limits of the card (a major
environmental warning). The card shut down to prevent
permanent damage.
Speed On 2-Gbps mode.
Off 1-Gbps mode.
Link Solid green Link is up.
Steady flashing
green
Link is up (beacon used to identify port).
Intermittent
flashing green
Link is up (traffic on port).
Solid yellow Link is disabled by software.
Flashing yellow A fault condition exists.
Off No link.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-50
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
32-Port Fibre Channel Storage Services Module
The 32-port Fibre Channel Storage Services Module (SSM) for the Cisco MDS 9000 Family supports
up to 32 Fibre Channel ports, provides distributed intelligent storage services, and supports future
storage services.
Note Cisco MDS 9500 Series switches running Cisco MDS SAN-OS Release 2.x, 3.x, or NX-OS Release
4.1(1b) support the SSM.
The Fibre Channel ports support hot-swappable Fibre Channel SFP transceivers, which can be short
wavelength (SWL) for connectivity up to 1640 ft (500 m), or long wavelength (LWL) for connectivity
up to 6.2 miles (10 km). All interfaces are autosensing 1-Gbps/2-Gbps compatible. The ports also
support coarse wavelength-division multiplexing (CWDM) SFP transceivers, which can be used for
extended long wavelength (EWL) transmission or for CWDM. For more information about SFP
transceivers, see the “Supported Transceivers” section on page 1-55.
Figure 1-32 shows the SSM.
Figure 1-32 Cisco MDS 9000 Family Storage Services Module
Each module draws power from the 42 V supplied on the backplane with local DC/DC power converters
and regulators.
The control processor on the module provides power-on, offline, and online diagnostics. The control
processor can be used to configure devices on the switching module and to gather statistical data from
each port.
The control processor monitors the DC/DC power source and temperature. The control processor signals
the SSM and displays an alarm on its front panel when it detects a problem.
The front panel of the SSM provides basic status information, such as power-on, self-test running,
self-test passed, alarm, and ready.
The binary image for the SSM is downloaded from the supervisor module. Prior to the image download,
the control processor on the services module runs from code stored on its local CompactFlash card. The
image for an SSM can be specified using the SSI boot variable. For details on how to specify the SSI
boot variable, see the Cisco MDS 9000 Family CLI Configuration Guide.
Note Software downloads are only necessary when a revision of the code is needed.
The SSM can force a reset and control whether or not power is applied to the switching module.
1Status LED 3Link and speed LEDs
21-Gbps/2-Gbps Fibre Channel port group 4Asset tag
120094
2
43
17 20
45
21 24
89
25 28
12 13
29 32
16
Storage Services Module
1
DS-X9032
Send documentation comments to mdsfeedback-doc@cisco.com.
1-51
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
If a single component or a set of components on the switching module fails, this failure will not disable
another switching module if that is the only failure in the system.
For the detection of most component failures, each switching module has a hardware watchdog timer
that resets the card if is not serviced periodically.
LEDs on the Storage Services Modules
Table 1-19 describes the LEDs for the Storage Services Modules.
Ta b l e 1-19 LEDs for the Cisco MDS 9000 Family Storage Services Modules
LED Status Description
Status Green All diagnostics pass. The module is operational (normal
initialization sequence).
Orange One of the following occurs or occurred:
The module is booting or running diagnostics (normal
initialization sequence).
The inlet air temperature of the system exceeded the
maximum system operating temperature limit (a minor
environmental warning). To assure maximum product life,
you should immediately correct the environmental
temperature and restore the system to normal operation.
Red One of the following occurred:
The diagnostic test failed. The module is not operational
because a fault occurred during the initialization sequence.
The inlet air temperature of the system exceeded the safe
operating temperature limits of the card (a major
environmental warning). The card shut down to prevent
permanent damage.
Speed On 2-Gbps mode.
Off 1-Gbps mode.
Link Solid green Link is healthy.
Steady flashing
green
Link is healthy and beacon is enabled.
Intermittent
flashing green
Link is up and traffic is flowing through port.
Solid yellow Link is disabled by software.
Flashing yellow A fault condition exists.
Off No link.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-52
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
Caching Services Module
The Caching Services Module (CSM) provides virtualization services that allow the Cisco MDS 9000
Family switches to reallocate physical resources as virtual resources for increased efficiency. The CSM
receives and sends data through the switch backplane. It has two disk drives, two internal batteries for
backup in case of power failure, and no external ports.
CSMs must be implemented in pairs in the fabric to provide redundancy and backup. Only two or more
CSMs in a fabric are supported. However, the CSMs do not have to be installed in the same switch.
The CSM may shut down because of the software, an external power failure, or the module separated
from the backplane while it still had power. The CSM automatically backs up the data in memory to the
disk drives and then shuts down. The CSM batteries provide adequate power to back up data without
external power.
Note The Cisco MDS 9513 does not support the CSM.
Figure 1-33 shows the CSM.
Figure 1-33 CSM
Figure 1-34 shows the location of the disk drives and batteries on the CSM.
Caution The batteries are shipped fully charged and should be handled with caution accordingly.
1Status LED 5Disk 1 Status LED
2Battery LED 6Node 2 LEDs
3Node 1 LEDs 7Node 2 Status LED
4Node 1 Status LED 8Disk 2 Status LED
91626
STATUS
DS-X9560-SMXX
BATTERY STATUS
NODE 1 NODE 2
DISK STATUS DISK
Cashing Services Module
3 6
852
1 4 7
Send documentation comments to mdsfeedback-doc@cisco.com.
1-53
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
Figure 1-34 CSM, Internal View
See the “Installing a Switching or Services Module, Including Caching Services Modules” section on
page 2-45 for information about installing the CSM and maintaining the CSM batteries.
1Disk drive 2 3Battery 2
2Disk drive 1 4Battery 1
94038
1
3
4
2
Send documentation comments to mdsfeedback-doc@cisco.com.
1-54
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Services Modules
LEDs on the Caching Services Module
Table 1-20 describes the LEDs for the CSM.
Ta b l e 1-20 LEDs for the Cisco MDS 9000 Family CSM
LED Status Description
Status Green All diagnostics pass, and the module is operational (normal
initialization sequence).
Orange One of the following occurs or occurred:
The module is booting or running diagnostics (normal
initialization sequence).
The inlet air temperature of the system exceeded the
maximum system operating temperature limit (a minor
environmental warning). To ensure maximum product life,
you should immediately correct the environmental
temperature and restore the system to normal operation.
Red One of the following occurred:
The diagnostic test failed. The module is not operational
because a fault occurred during the initialization sequence.
The inlet air temperature of the system exceeded the safe
operating temperature limits of the card (a major
environmental warning). The card shut down to prevent
permanent damage.
Node Green Node is fully operational.
Flashing green Node is not yet part of a cluster.
Orange The module is booting or node is administratively down.
Flashing orange Node is in service mode.
Red Node failure.
Off Node does not have power.
Battery Green Battery has sufficient charge to dump cache.
Flashing green Battery is charging and has sufficient charge to dump cache.
Battery conditioning in progress.
Flashing orange Battery is charging but has insufficient charge to dump cache.
Red Battery failure or battery is charged to the extent possible but in-
sufficient to dump cache; replace CSM.
Off Battery does not have power and is not charged.
Disk Solid green Disk is operational.
Flashing orange Dumping cache to disk.
Flashing green Restoring cache from disk.
Red Disk failure.
Off Disk does not have power.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-55
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Supported Transceivers
Supported Transceivers
The following types of transceivers are available from Cisco and are supported on the Cisco MDS 9500
Series:
X2 transceivers
Fibre Channel SFP and SFP+ transceivers, in either SWL or LWL
Combination Fibre Channel/Gigabit Ethernet SFP transceivers, in either SWL or LWL
Combination Fibre Channel/Gigabit Ethernet CWDM SFP transceivers, which can be used for
ELWL transmission or for CWDM
Gigabit Ethernet SFP transceiver, 1-Gbps copper
Fibre Channel DWDM SFP transceiver, which can be used for ELWL transmission or for DWDM
Note Switches running Cisco MDS SAN-OS Release 1.x, 2.x, 3.x, or NX-OS Release 4.1(1b) support
combination Fibre Channel/Gigabit Ethernet SFP transceivers.
The transceivers are field-replaceable and hot-swappable. You can use any combination of SFP
transceivers that are supported by the switch. The only restrictions are that SWL transceivers must be
paired with SWL transceivers, and LWL transceivers with LWL transceivers, and the cable must not
exceed the stipulated cable length for reliable communications.
For more information about the X2 transceiver, see the X2 Transceiver Specifications” section on
page D-19.
For more information about a specific Cisco SFP transceiver, see the “SFP and SFP+ Transceiver
Specifications” section on page D-22. SFP transceivers can be ordered separately or with the Cisco MDS
9500 Series.
Note Use only Cisco transceivers in the Cisco MDS 9500 Series. Each Cisco transceiver is encoded with
model information that enables the switch to verify that the transceiver meets the requirements for the
switch.
X2 Transceivers
The X2 transceiver is a small form-factor transceiver optimized for 10-Gbps applications and uses an SC
connector. The X2 transceiver is ideally suited for Ethernet, Fibre Channel and telecom switches, and
standard (PCI) peripheral component interconnect based server and storage connections. The X2
provides robust thermal performance and electromagnetic shielding.
For more information about X2 transceiver specifications, see the “X2 Transceiver Specifications”
section on page D-19.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-56
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Supported Transceivers
Fibre Channel SFP Transceivers
Cisco Fibre Channel SFP transceivers are available in SWL or LWL versions. Both of these versions are
1-Gbps/2-Gbps/4-Gbps capable. Cisco Fibre Channel SFP+ transceivers are available in SWL or LWL
versions. Both of these versions are 2-Gbps/4-Gbps/8-Gbps capable.
Cisco Fibre Channel SFP transceivers have LC connectors and comply with 1-Gbps/2-Gbps/4-Gbps
Fibre Channel standards as defined in FC-PI 10.0 2. Cisco Fibre Channel SFP+ transceivers have LC
connectors and comply with 2-Gbps/4-Gbps/8-Gbps Fibre Channel standards as defined in FC-PI-4.
For more information about Fibre Channel SFP and SFP+ transceiver specifications, see the “SFP and
SFP+ Transceiver Specifications” section on page D-22.
Combination Fibre Channel/Gigabit Ethernet SFP Transceivers
The combination Fibre Channel/Gigabit Ethernet SFP transceivers from Cisco Systems are available in
SWL or LWL versions. Both of these versions are 1-Gbps/2-Gbps capable.
The combination SFP transceivers from Cisco Systems have LC connectors and comply with
1-Gbps/2-Gbps Fibre Channel as defined in FC-PI 10.0 2 and Gigabit Ethernet as defined in IEEE
802.3z.
For more information about Fibre Channel/Gigabit Ethernet SFP transceiver specifications, see the “SFP
and SFP+ Transceiver Specifications” section on page D-22.
CWDM Combination Fibre Channel/Gigabit Ethernet SFP Transceivers
The Cisco CWDM SFP transceivers have LC connectors and support Gigabit Ethernet and
1-Gbps/2-Gbps Fibre Channel. They match the wavelength plan of Cisco CWDM GBICs and Cisco
CWDM optical add/drop multiplexers (OADMs). Cisco 4-Gbps CWDM SFP transceivers are also
available.
CWDM SFP transceivers are used in the following ways:
CWDM transmission can send and receive up to eight laser wavelengths carrying different signals
simultaneously on the same optical fiber using an OADM.
ELWL signals can transmit over longer distances than LWL SFP transceivers.
There are eight different “colors” of CWDM SFP transceivers, one for each fixed wavelength. The
fiber-optic cables from the CWDM SFP transceivers must be connected to an OADM. The OADM
combines the wavelengths of the different outgoing signals into one composite send signal. The OADM
also separates the received transmissions into the different wavelengths and sends them to the
corresponding CWDM SFP transceiver.
For more information about CWDM SFP transceiver specifications, see the “SFP and SFP+ Transceiver
Specifications” section on page D-22.
Gigabit Ethernet SFP Transceivers
The 4-port and 8-port IP Storage services (IPS-4 and IPS-8) modules provide four or eight 1-Gigabit
Ethernet ports that support Gigabit Ethernet SFP transceivers. The Gigabit Ethernet SFP transceivers
have RJ-45 connectors and support Gigabit Ethernet (1-Gbps).
Send documentation comments to mdsfeedback-doc@cisco.com.
1-57
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Supported Transceivers
For more information about Gigabit Ethernet SFP transceiver specifications, see the “SFP and SFP+
Transceiver Specifications” section on page D-22.
DWDM Fibre Channel SFP Transceivers
The Cisco DWDM SFP transceivers have LC connectors and support 1-Gbps/2-Gbps Fibre Channel. The
DWDM SFP transceivers match the International Telecommunications Union (ITU) 100-Ghz
wavelength grid and the wavelength plan of Cisco 100-Ghz ONS product family.
DWDM SFP transceivers are used in the following ways:
DWDM transmission can send and receive up to 32 laser wavelengths carrying different signals
simultaneously on the same optical fiber using an optical filter.
ELWL signals can transmit over longer distances than LWL SFP transceivers.
For more information about Gigabit Ethernet SFP transceiver specifications, see the “SFP and SFP+
Transceiver Specifications” section on page D-22.
Send documentation comments to mdsfeedback-doc@cisco.com.
1-58
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Supported Transceivers
CHAPTER
Send documentation comments to mdsfeedback-doc@cisco.com.
2-1
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
2
Installing the Cisco MDS 9500 Series
This chapter describes how to install the Cisco MDS 9500 Series chassis and its components, and
includes the following information:
Preinstallation, page 2-2
Installing the Chassis in a Cabinet or Rack, page 2-6
System Grounding, page 2-17
Grounding the Chassis, page 2-23
Starting Up the Switch, page 2-28
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules, page 2-38
Maintaining a Caching Services Module, page 2-50
Removing and Installing a Power Supply or PEM, page 2-51
Removing and Installing Fan Modules, page 2-68
Removing and Installing CompactFlash Cards, page 2-75
Removing and Installing Clock Modules, page 2-76
Note Before you install, operate, or service the system, read the Regulatory Compliance and Safety
Information for the Cisco MDS 9000 Family for important safety information.
Warning
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol indicates danger. You are in a situation that could cause physical injury. Before
you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this device.
Statement 1071
SAVE THESE INSTRUCTIONS
Warning
This unit is intended for installation in restricted access areas. A restricted access area can be
accessed only through the use of a special tool, lock and key, or other means of security.
Statement 1017
Send documentation comments to mdsfeedback-doc@cisco.com.
2-2
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Preinstallation
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Statement
1022
Preinstallation
This section provides the following topics:
Installation Options, page 2-2
Installation Guidelines, page 2-3
Required Equipment, page 2-5
Unpacking and Inspecting the Switch, page 2-5
Installation Options
The Cisco MDS 9513 Director can be installed using the following methods:
In an open four-post EIA rack, using:
The rack-mount kit shipped with the switch
The Cisco MDS 9509 Director can be installed using the following methods:
In an open EIA rack, using:
The rack-mount kit shipped with the switch
The telco and EIA Shelf Bracket Kit (optional and purchased separately) in addition to the
rack-mount kit shipped with the switch
In a perforated or solid-walled EIA cabinet, using:
The rack-mount kit shipped with the switch
The telco and EIA Shelf Bracket Kit (optional and purchased separately) in addition to the
rack-mount kit shipped with the switch
In a two-post telco rack using the rack-mount kit shipped with the switch
In a four-post nonthreaded cabinet or rack using the optional 9500 Shelf Bracket Kit
The Cisco MDS 9506 Director can be installed using the following methods:
In an open EIA rack, using:
The rack-mount kit shipped with the switch
The telco and EIA Shelf Bracket Kit (optional and purchased separately) in addition to the
rack-mount kit shipped with the switch
In a perforated or solid-walled EIA cabinet, using:
The rack-mount kit shipped with the switch
Send documentation comments to mdsfeedback-doc@cisco.com.
2-3
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Preinstallation
The telco and EIA Shelf Bracket Kit (optional and purchased separately) in addition to the
rack-mount kit shipped with the switch
In a two-post telco rack, using:
The rack-mount kit shipped with the switch
The telco and EIA Shelf Bracket Kit (optional and purchased separately) in addition to the front
brackets shipped with the switch
For instructions on installing the switch using the rack-mount kit shipped with the switch, see
the“Installing the Chassis in a Cabinet or Rack” section on page 2-6.
For instructions on installing the switch using the optional telco and EIA Shelf Bracket Kit (purchased
separately), see the “Cisco MDS 9000 Family Telco and EIA Shelf Bracket” section on page C-6.
Note The telco and EIA Shelf Bracket Kit is optional and is not provided with the switch. To order the kit,
contact your switch provider.
Note The telco and EIA Shelf Bracket Kit is not intended for use with a Cisco MDS 9513 Director or Cisco
MDS 9509 Director in a two-post telco rack.
Installation Guidelines
Follow these guidelines when installing the Cisco MDS 9500 Series:
Plan your site configuration and prepare the site before installing the chassis. Cisco recommends
that you use the site planning tasks listed in Appendix F, “Site Planning and Maintenance Records.
Ensure that there is adequate space around the switch to allow for servicing the switch and for
adequate airflow (airflow requirements are listed in Appendix D, “Technical Specifications”).
Ensure that the air-conditioning meets the heat dissipation requirements listed in Appendix D,
“Technical Specifications.
Ensure that the cabinet or rack meets the requirements listed in Appendix C, “Cabinet and Rack
Requirements.
Note Jumper power cords are available for use in a cabinet. For more information, see the “Jumper Power
Cord” section on page E-11.
Ensure that the chassis is adequately grounded. Grounding the chassis is recommended in all cases,
and is mandatory for Cisco MDS 9506 Directors that have a DC power supply installed. If the switch
is not mounted in a grounded rack or cabinet, Cisco recommends connecting the system ground on
the chassis and the power supply ground to an earth ground, regardless of whether the power
supplies are AC or DC.
Ensure that the site power meets the power requirements listed in Appendix D, “Technical
Specifications. You can use an uninterruptible power supply (UPS) to protect against power
failures.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-4
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Preinstallation
Caution Avoid UPS types that use ferroresonant technology. These UPS types can become unstable
with systems such as the Cisco MDS 9000 Family, which can have substantial current draw
fluctuations because of fluctuating data traffic patterns.
Ensure that circuits are sized according to local and national codes. For North America:
The 1900-W AC power supplies require a 20-A circuit.
The 1900-W DC power supplies require a 70-A circuit.
The 2500-W AC power supplies require a 20-A circuit.
The 2500-W DC power supplies require a 100-A circuit.
The 4000-W AC power supplies require a 30-A circuit.
The 6000-W AC power supplies require two 220 V inputs at 20-A circuit.
If you are using 200/240 VAC power sources in North America, the circuits must be protected by
two-pole circuit breakers.
Caution To prevent loss of input power, ensure that the total maximum loads on the circuits supplying
power are within the current ratings of the wiring and breakers.
Record your installation and configuration information as you work. See Appendix F, “Site Planning
and Maintenance Records.
Use the following screw torques when installing the switch:
Captive screws: 4 in-lb
M3 screws: 4 in-lb
M4 screws: 12 in-lb
M6 screws: 20 in-lb
10-32 screws: 20 in-lb
12-24 screws: 30 in-lb
Send documentation comments to mdsfeedback-doc@cisco.com.
2-5
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Preinstallation
Required Equipment
Gather the following items before beginning the installation:
Number 1 and number 2 Phillips screwdrivers with torque capability.
3/16-inch flat-blade screwdriver.
Tape measure and level.
ESD wrist strap or other grounding device.
Antistatic mat or antistatic foam.
In addition to the grounding items provided in the accessory kit, you need the following items:
Grounding cable (6 AWG recommended), sized according to local and national installation
requirements; the required length depends on the proximity of the Cisco MDS 9500 to proper
grounding facilities.
Crimping tool large enough to accommodate girth of lug.
Wire-stripping tool.
For DC power supplies in a Cisco MDS 9506 Director, you need two 10-32 ring lugs for each DC
power supply.
For the Cisco MDS 9513 Director, you need a mechanical lift to handle the weight of the chassis.
Unpacking and Inspecting the Switch
Warning
Two people are required to lift the chassis. Grasp the chassis underneath the lower edge and lift with
both hands. To prevent injury, keep your back straight and lift with your legs, not your back. To prevent
damage to the chassis and components, never attempt to lift the chassis with the handles on the
power supplies or on the interface processors, or by the plastic panels on the front of the chassis.
These handles were not designed to support the weight of the chassis.
Statement 5
Caution Use a mechanical lift to lift the MDS 9513 chassis. The Cisco MDS 9513 Director can weigh up to 375 lb
(170 kg) when fully loaded, depending on what modules populate the chassis.
Caution Cisco recommends that a third person assist whenever the chassis is being moved or lifted. The Cisco
MDS 9509 Director weighs approximately 170 lb (77 kg) when fully loaded, and the Cisco MDS 9506
Director weighs approximately 125 lb (57 kg) when fully loaded with all modules and power supplies.
Caution When handling switch components, wear an ESD strap and handle modules by the carrier edges only.
An ESD socket is provided on the chassis. For the ESD socket to be effective, the chassis must be
grounded either through the power cable, the chassis ground, or metal-to-metal contact with a grounded
rack.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-6
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Installing the Chassis in a Cabinet or Rack
Tip Keep the shipping container for use when moving or shipping the chassis in the future. The shipping
carton can be flattened and stored with the pallet.
Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical support.
If you purchased this product directly from Cisco Systems, contact Cisco Technical Support at this URL:
http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml.
Note The switch is thoroughly inspected before shipment. If any damage occurred during transportation or
any items are missing, contact your customer service representative immediately.
To inspect the shipment, follow these steps:
Step 1 Compare the shipment to the equipment list provided by your customer service representative and ensure
that you have received all items, including the following:
Print documentation and CD-ROMs
Grounding lug kit
Rack-mount kit
ESD wrist strap
Cables and connectors
Any optional items ordered
Step 2 Check for damage and report any discrepancies or damage to your customer service representative. Keep
the following information ready:
Invoice number of shipper (see packing slip)
Model and serial number of the damaged unit
Description of damage
Effect of damage on the installation
Installing the Chassis in a Cabinet or Rack
This section describes how to install the Cisco MDS 9500 Series in a cabinet or rack that meets the
requirements described in this document, using the rack-mount kit provided with the switch. A separate
procedure is provided for each type of director:
Installing the Cisco MDS 9513 Director in a Rack, page 2-7
Installing the Cisco MDS 9509 Director in a Rack, page 2-11
Installing the Cisco MDS 9506 Director in a Rack, page 2-15
Caution If the rack is on wheels, ensure that the brakes are engaged or that the rack is otherwise stabilized.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-7
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Installing the Chassis in a Cabinet or Rack
Note You can remove the modules and other field-replaceable components to make moving and positioning
the chassis easier and safer. See the “Removing, Installing, and Verifying Supervisor, Switching, and
Services Modules” section on page 2-38 for instructions specific to the component.
Installing the Cisco MDS 9513 Director in a Rack
The 6000-W AC power supplies for the Cisco MDS 9513 Director are designed to provide an output
power for the modules and fans. Each power supply has two AC power connections and will provide
power as follows:
One AC power connection @110 VAC = No output
Two AC power connection @110 VAC = 2900-W output
One AC power connection @ 220 VAC = 2900-W output
Two AC power connection @ 220 VAC = 6000-W output
Note Power output does not include the power used by the individual modules used in the chassis.
Installation of the Cisco MDS 9513 Director in a rack requires a mechanical lift to place the chassis in
the rack. Ensure that you have access to the lift during the installation process.
Table 2-1 lists the items provided in the Cisco MDS 9513 rack-mount kit.
Note The rack-mount kit for the Cisco MDS 9513 Director includes rack-mount support brackets, which are
required for the duration of the installation and are not removable.
To install the Cisco MDS 9513 chassis in a rack using the rack-mount kit provided with the switch,
follow these steps:
Step 1 Adjust the distance between the front and rear cabinet vertical rack-mount rails to 26.56 ± 0.15 in. (67.46
cm). This step must be performed prior to installing the support rack-mount brackets.
Step 2 Position one of the support rack-mount brackets in the rack and adjust it to the depth of the cabinet rack.
Repeat this step for the other side. Use the screws to secure the brackets but do not tighten them yet.
Ta b l e 2-1 Contents for the Rack-Mount Support Bracket Kit
Quantity Part Description
2Rack-mount support bracket
2Rack-mount support bar
20 12-24 x 3/4-in. Phillips screws
20 10-32 x 3/4-in. Phillips screws
Send documentation comments to mdsfeedback-doc@cisco.com.
2-8
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Installing the Chassis in a Cabinet or Rack
Note If you are using the cable management bracket shipped with the switch, do not install the top
four screws into the front right of the bracket. However, you must install the bottom screw (see
Figure 2-1). The top four screws will be used to install the cable management bracket to the rail.
Figure 2-1 Positioning the Rack-Mount Support Brackets
Step 3 Install one rack-mount support bar into the slots located on the rack-mount support brackets. Repeat this
for the other support bar.
146035
26.56 in
Send documentation comments to mdsfeedback-doc@cisco.com.
2-9
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Installing the Chassis in a Cabinet or Rack
Figure 2-2 Positioning the Support Bars
Step 4 Once the support bars are installed, secure the rack-mount support brackets to the rack using the screws
provided.
Note If you are using the cable management bracket shipped with the switch, do not install the top
four screws to the front right side of the bracket. These will be installed after placing the cable
management bracket along that side. The bottom screw should be installed to support the front
of the rack-mount support bracket.
1Screws 3Rack-mount support bar
2Rack-mount support bracket
146034
2
2
1
1
1
1
3
3
Send documentation comments to mdsfeedback-doc@cisco.com.
2-10
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Installing the Chassis in a Cabinet or Rack
Figure 2-3 Securing the Rack-Mount Support Brackets
Step 5 Position a person at each side of the chassis and one at the mechanical lift. Place the chassis on the lift
by lifting on the top front of rear of the chassis.
Step 6 Using the mechanical lift, lift the chassis up onto the rack-mount support brackets.
Step 7 Place the rear of the chassis on the rack-mount support brackets between the front mounting rails.
Step 8 Manually slide the chassis into the rack until it rests on the crossbar and the side rack-mount brackets.
Step 9 If you are installing the optional cable management brackets, place the cable management brackets in
front of the right rack-mount brackets. Align the holes in the cable management brackets with the holes
in the front rack-mount brackets on the right and mounting rails, and then insert the screws.
Step 10 Align the holes in the front rack-mount bracket with the holes in the mounting rails and insert the 12-24
x 3/4-inch or 10-32 x 3/4-inch screws, using six screws per side. (See Figure 2-4.)
Note Use a minimum of six screws to ensure that the switch is adequately supported.
146036
Send documentation comments to mdsfeedback-doc@cisco.com.
2-11
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Installing the Chassis in a Cabinet or Rack
Figure 2-4 Installing the Cable Management Brackets on the MDS 9513 Chassis
Installing the Cisco MDS 9509 Director in a Rack
Caution If connecting a Cisco MDS 9509 Director to a 110-VAC power system, ensure that sufficient power is
provided to meet the chassis power requirements for the number of modules installed.
When connected to 220 VAC, the 2500-W AC power supplies (DS-CAC-2500W) for the Cisco MDS
9509 Director are designed to provide an output power of 2331 W to power the modules and fans. When
connected to a 110 VAC power system, the power supply provides approximately 1150 W. In this case,
and if the power supplies are used in redundant rather than combined mode, they might not provide
adequate power, depending on the number of modules loaded in the chassis.
If a 110-VAC input is chosen, a 110-VAC power cord (CAB-7513AC=) must be ordered separately.
Table 2-2 lists the items provided in the Cisco MDS 9509 rack-mount kit.
1Screws, 12-24 or 10-32 3Mounting rail
2Support bracket 4Cable guide
146038
1
4
3
2
Send documentation comments to mdsfeedback-doc@cisco.com.
2-12
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Installing the Chassis in a Cabinet or Rack
Note The rack-mount kit for the Cisco MDS 9509 Director includes side rack-mount brackets, which are
required for the duration of the installation only and can be removed once the front rack-mount brackets
are securely fastened to the rack-mounting rails.
Note The Cisco MDS 9500 Shelf Bracket Kit can be purchased as an optional shelf bracket kit for the Cisco
MDS 9509 Director. See “Cisco MDS 9500 Shelf Bracket” section on page C-13.
To install the Cisco MDS 9509 chassis in a rack using the rack-mount kit provided with the switch,
follow these steps:
Step 1 Position one of the side rack-mount brackets in the rack as shown in Figure 2-5. Secure the side
rack-mount bracket to the rack using three of the 12-24 x 3/4-inch or 10-32 x 3/4-inch screws, depending
on the type of holes in the mounting rails.
Step 2 Repeat for the second side rack-mount bracket, ensuring that the side rack-mount brackets are at the
same height.
Ta b l e 2-2 Contents of Cisco MDS 9509 Rack-Mount Kit
Quantity Part Description
3 RU shelf bracket kit
612-24 x 3/4-inch Phillips binder-head screws
610-32 x 3/4-inch Phillips binder-head screws
2M3 x 8-mm Phillips pan-head screws
2Side rack-mount brackets
1Crossbar bracket
Cable management bracket kit
2Cable management brackets
18 12-24 x 3/4-inch Phillips binder-head screws
18 10-32 x 3/4-inch Phillips binder-head screws
Send documentation comments to mdsfeedback-doc@cisco.com.
2-13
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Installing the Chassis in a Cabinet or Rack
Figure 2-5 Installing the Side Rack-Mount Brackets for the Cisco MDS 9509 Chassis
Step 3 Attach the crossbar to the back of the side rack-mount brackets using one M3 x 8-mm screw per side as
shown in Figure 2-6.
Figure 2-6 Attaching the Crossbar to the Side Rack-Mount Brackets (Rear View)
Step 4 Position a person at each side of the chassis. Grasp the chassis handle with one hand and use the other
hand near the back of the chassis for balance. Slowly lift the chassis in unison, avoiding sudden twists
or moves to prevent injury. Place the rear of the chassis on the side rack-mount brackets between the
front mounting rails, and slide it until it rests on the crossbar and the side rack-mount brackets (see
Figure 2-7).
1Side rack-mount bracket 2Screws, 12-24 or 10-32
94997
1 2 1
1Side rack-mount bracket 3Screws, M3
2Side rack-mount bracket 4Crossbar
94995
Front of rack
1
2
3
4
3
Send documentation comments to mdsfeedback-doc@cisco.com.
2-14
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Installing the Chassis in a Cabinet or Rack
Figure 2-7 Installing the Cisco MDS 9509 Chassis in the Rack
Step 5 If you are installing the optional cable management bracket, place the cable management bracket in front
of the front right rack-mount brackets. Align the holes in the cable management brackets with the holes
in the front rack-mount brackets and mounting rails, and then insert the screws.
Note Because the fan tray is on the left side of the chassis, Cisco recommends using only the right
side for cable management. Using the right side for cable management allows easy removal of
the fan tray if you need to replace a fan.
Step 6 Align the holes in the front rack-mount bracket with the holes in the mounting rails and insert the 12-24
x 3/4-inch or 10-32 x 3/4-inch screws (see Figure 2-8), using six screws per side.
Note Use a minimum of six screws per side to ensure that the switch is adequately supported.
13
2
90022
1Crossbar 3Side rack-mount bracket
2Mounting rail
Send documentation comments to mdsfeedback-doc@cisco.com.
2-15
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Installing the Chassis in a Cabinet or Rack
Figure 2-8 Installing the Cable Management Bracket on the MDS 9509 Chassis
Installing the Cisco MDS 9506 Director in a Rack
Table 2-3 lists the items provided in the Cisco MDS 9506 rack-mount kit. The kit contains extra M4
screws in case the front rack-mount brackets were removed from the switch and must be reinstalled.
Note The rack-mount kit for the Cisco MDS 9506 Director does not include side rack-mount brackets, because
they are not required to install the Cisco MDS 9506 Director.
1Screws, 12-24 or 10-32 3Mounting rail
2Front rack-mount bracket (behind
cable guide)
4Cable guide
99023
1
4
2
3
Send documentation comments to mdsfeedback-doc@cisco.com.
2-16
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Installing the Chassis in a Cabinet or Rack
Figure 2-9 shows the installation of a Cisco MDS 9506 director into a rack, using the cable management
bracket.
Figure 2-9 Installing the Cisco MDS 9506 Chassis in the Rack
Ta b l e 2-3 Contents of Cisco MDS 9506 Rack-Mount Kit
Quantity Part Description
14 12-24 x 3/4-in. Phillips binder-head screws
14 10-32 x 3/4-in. Phillips binder-head screws
14 M4 x 6-mm Phillips pan-head screws
2Cable management brackets
99021
2
4
13
1Screws, 12-24 or 10-32 3Mounting rail
2Front rack-mount bracket (behind cable
guide)
4Cable management bracket
Send documentation comments to mdsfeedback-doc@cisco.com.
2-17
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
System Grounding
To install the Cisco MDS 9506 chassis in the rack using the rack-mount kit, follow these steps:
Step 1 Place all the parts and screwdrivers near the rack for easy access while attaching the switch to the rack.
Note The front rack-mount brackets are shipped installed on the switch. If they have been uninstalled,
reinstall them on the switch using the M4 x 6-mm screws.
Step 2 Position a person at each side of the chassis. Grasp the bottom of the chassis and slowly lift the chassis
in unison, avoiding sudden twists or moves to prevent injury. Insert the rear of the chassis between the
front mounting rails (see Figure 2-9), supporting the switch inside the rack until the next step is
complete.
Step 3 If you are installing the optional cable management bracket, align the holes in the cable management
bracket with the holes in the front, right rack-mount brackets and the mounting rail. Ensure that the
chassis is level, and pass the screws through the cable management brackets and front rack-mount
bracket and into the mounting rail.
Note Because the fan tray is on the left side of the chassis, Cisco recommends using only the right
side for cable management. This allows easy removal of the fan tray if you need to replace a fan.
Step 4 Align the holes in the front rack-mount bracket with the holes in the mounting rail, and ensure that the
chassis is level. Insert the 12-24 x 3/4-inch or 10-32 x 3/4-inch screws (depending on the type of holes
in the mounting rails) through the holes in the front rack-mount bracket and into the holes in the
mounting rails, using four screws per side.
Caution Use a minimum of four screws per side to ensure that the switch is adequately supported by
the front rack-mount brackets.
System Grounding
This section describes the need for system grounding and explains how to prevent damage from
electrostatic discharge.
Proper Grounding Practices
Grounding is one of the most important parts of equipment installation. Proper grounding practices
ensure that the buildings and the installed equipment within them have low-impedance connections and
low-voltage differentials between chassis. When you properly ground systems during installation, you
reduce or prevent shock hazards, equipment damage due to transients, and data corruption. Table 2-4
lists grounding best practices.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-18
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
System Grounding
Ta b l e 2-4 Grounding Best Practices
Environment
Electromagnetic Noise Severity
Level Grounding Recommendations
Commercial building is
subjected to direct lightning
strikes.
For example, some places in the
United States, such as Florida,
are subject to more lightning
strikes than other areas.
High All lightning protection devices
must be installed in strict
accordance with manufacturer
recommendations. Conductors
carrying lightning current
should be spaced away from
power and data lines in
accordance with applicable
recommendations and codes.
Appropriate grounding practices
must be closely followed.
Commercial building is located
in an area where lightning
storms frequently occur but is
not subject to direct lightning
strikes.
High Appropriate grounding practices
must be closely followed.
Commercial building contains a
mix of information technology
equipment and industrial
equipment, such as welding.
Medium to high Appropriate grounding practices
must be closely followed.
Existing commercial building is
not subject to natural
environmental noise or
man-made industrial noise. This
building contains a standard
office environment. This
installation has a history of
malfunction due to
electromagnetic noise.
Medium Appropriate grounding practices
must be closely followed.
Determine source and cause of
noise if possible, and mitigate as
closely as possible at the noise
source or reduce coupling from
the noise source to the victim
equipment.
New commercial building is not
subject to natural environmental
noise or man-made industrial
noise. This building contains a
standard office environment.
Low Appropriate grounding practices
should be followed as closely as
possible. Electromagnetic noise
problems are not anticipated, but
installing a best practice
grounding system in a new
building is often the least
expensive route and the best way
to plan for the future.
Existing commercial building is
not subject to natural
environmental noise or
man-made industrial noise. This
building contains a standard
office environment.
Low Appropriate grounding practices
should be followed as much as
possible. Electromagnetic noise
problems are not anticipated, but
installing a best practice
grounding system is always
recommended.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-19
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
System Grounding
Note In all situations, grounding practices must comply with local National Electric Code (NEC)
requirements or local laws and regulations.
Note Always ensure that all of the modules are completely installed and that the captive installation screws
are fully tightened. In addition, ensure that all I/O cables and power cords are properly seated. These
practices are normal installation practices and must be followed in all installations.
Preventing Electrostatic Discharge Damage
Electrostatic discharge (ESD) damage, which can occur when modules or other FRUs are improperly
handled, results in intermittent or complete failures. Modules consist of printed circuit boards that are
fixed in metal carriers. Electromagnetic interference (EMI) shielding and connectors are integral
components of the carrier. Although the metal carrier helps protect the board from ESD. Always wear
an ESD grounding strap when handling modules.
Follow these guidelines for preventing ESD damage:
Always wear an ESD wrist strap and ensure that it makes maximum contact with bare skin. ESD
grounding straps are available with banana plugs, metal spring clips, or alligator clips. All MDS
9500 series chassis are equipped with a banana plug connector (identified by the ground symbol next
to the connector) somewhere on the front panel. Cisco recommends that you use a personal ESD
grounding strap equipped with a banana plug.
If you choose to use the disposable ESD wrist strap supplied with most FRUs or an ESD wrist strap
equipped with an alligator clip, you must attach the system ground lug to the chassis in order to
provide a proper grounding point for the ESD wrist strap.
Note This system ground is also referred to as the network equipment building system (NEBS) ground.
If your chassis does not have the system ground attached, you must install the system ground lug.
For installation instructions and location of the chassis system ground pads, see “Establishing the
System Ground” section on page 2-22.
Note You do not need to attach a supplemental system ground wire to the system ground lug; the lug provides
a direct path to the bare metal of the chassis.
After you install the system ground lug, follow these steps to correctly attach the ESD wrist strap:
Step 1 Attach the ESD wrist strap to bare skin as follows:
a. If you are using the ESD wrist strap supplied with the FRUs, open the wrist strap package and
unwrap the ESD wrist strap. Place the black conductive loop over your wrist and tighten the strap
so that it makes good contact with your bare skin.
b. If you are using an ESD wrist strap equipped with an alligator clip, open the package and remove
the ESD wrist strap. Locate the end of the wrist strap that attaches to your body and secure it to your
bare skin.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-20
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
System Grounding
Step 2 Grasp the spring or alligator clip on the ESD wrist strap and momentarily touch the clip to a bare metal
spot (unpainted surface) on the rack. Cisco recommends that you touch the clip to an unpainted rack rail
so that any built-up static charge is then safely dissipated to the entire rack.
Step 3 Attach either the spring clip or the alligator clip to the ground lug screw as follows (see Figure 2-10):
a. If you are using the ESD wrist strap that is supplied with the FRUs, squeeze the spring clip jaws
open, position the spring clip to one side of the system ground lug screw head, and slide the spring
clip over the lug screw head so that the spring clip jaws close behind the lug screw head.
Note The spring clip jaws do not open wide enough to fit directly over the head of the lug screw or
the lug barrel.
b. If you are using an ESD wrist strap that is equipped with an alligator clip, attach the alligator clip
directly over the head of the system ground lug screw or to the system ground lug barrel.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-21
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
System Grounding
Figure 2-10 Attaching the ESD Wrist Strap to the System Ground Lug Screw
c. In addition, follow these guidelines when handling modules:
Handle carriers by available handles or edges only; avoid touching the printed circuit boards or
connectors.
Place a removed component board-side-up on an antistatic surface or in a static shielding
container. If you plan to return the component to the factory, immediately place it in a static
shielding container.
1ESD ground strap 4Clip installed (behind screw)
2Clip and grounding lug 5System ground connector
3Side view of grounding lug (clip slid behind
screw)
133947
2
1
3
5
4
2 pt
Send documentation comments to mdsfeedback-doc@cisco.com.
2-22
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
System Grounding
Never attempt to remove the printed circuit board from the metal carrier.
Caution For safety reasons, check the resistance value of the antistatic strap periodically. The measurement
should be between 1 and 10 megohm (Mohm).
Establishing the System Ground
This section describes how to connect a system ground to the MDS 9500 series switches.
Note This system ground is also referred to as the network equipment building system (NEBS) ground.
You must use the system (NEBS) ground on both AC- and DC-powered systems if you are installing this
equipment in a U.S. or European Central Office.
The system (NEBS) ground provides additional grounding for EMI shielding requirements and
grounding for the low-voltage supplies (DC-DC converters) on the modules and is intended to satisfy the
Telcordia Technologies NEBS requirements for supplemental bonding and grounding connections. You
must observe the following system grounding guidelines for your chassis:
You must install the system (NEBS) ground connection with any other rack or system power ground
connections that you make. The system ground connection is required if this equipment is installed
in a U.S. or European Central Office.
You must connect both the system (NEBS) ground connection and the power supply ground
connection to an earth ground. The system (NEBS) ground connection is required if this equipment
is installed in a U.S. or European Central Office.
For MDS 9500 series chassis that are equipped with DC-input power supplies, you must install the
system (NEBS) ground before you attach the source DC power cables to the DC PEM. If the chassis
is powered up, you must power down the chassis before attaching the system (NEBS) ground. If you
are installing the system (NEBS) ground on models of the MDS 9500 series chassis that are
equipped with either AC-input or DC-input power supplies, you do not need to power down the
chassis.
Note The system (NEBS) ground serves as the primary safety ground for the MDS 9500 series chassis that are
equipped with DC-input PEMs. The DC-input power supplies for these chassis do not have a separate
ground.
Required Tools and Equipment
To connect the ground system, you need the following tools and materials:
Grounding lug—A two-hole standard barrel lug. Supports up to 6 AWG wire. Supplied as part of
accessory kit.
Grounding screws—Two M4 x 8mm (metric) pan-head screws. Supplied as part of the accessory kit.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-23
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Grounding the Chassis
Grounding wire—Not supplied as part of accessory kit. The grounding wire should be sized
according to local and national installation requirements. Depending on the power supply and
system, a 12 AWG to 6 AWG copper conductor is required for U.S. installations. Commercially
available 6 AWG wire is recommended. The length of the grounding wire depends on the proximity
of the switch to proper grounding facilities.
No. 1 Phillips screwdriver.
Crimping tool to crimp the grounding wire to the grounding lug.
Wire-stripping tool to remove the insulation from the grounding wire.
Grounding the Chassis
This section describes how to connect the Cisco MDS 9500 Series to earth ground.
You must complete this procedure before connecting system power or powering up your shelf.
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Statement 1046
Figure 2-11 shows the system ground location on the front panel of the Cisco MDS 9513 chassis.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-24
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Grounding the Chassis
Figure 2-11 System Ground Location on the Cisco MDS 9513 Chassis (Front)
Figure 2-12 shows the ESD ground location on the rear panel of the Cisco MDS 9513 chassis.
1Grounding cable 4Close-up of grounding pad on switch
2Screws, M4, with square cone washers 5ESD plug
3NRTL listed grounding lug
144510
4
1
2
3
5
Send documentation comments to mdsfeedback-doc@cisco.com.
2-25
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Grounding the Chassis
Figure 2-12 ESD Ground Location on the Cisco MDS 9513 Chassis (Rear)
Caution All power supplies must be grounded. The receptacles of the AC power cables used to provide power to
the chassis must be the grounding type, and the grounding conductors should connect to protective earth
ground at the service equipment. For a Cisco MDS 9509 Director with a DC power supply, a grounding
cable must be connected to the terminal block. For a Cisco MDS 9506 Director with a DC power supply,
the chassis ground is required.
Figure 2-13 shows the system ground location on the Cisco MDS 9509 chassis.
1ESD plug 2ESD socket
144509
12
Send documentation comments to mdsfeedback-doc@cisco.com.
2-26
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Grounding the Chassis
Figure 2-13 System Ground Location on the Cisco MDS 9509 Chassis
Caution Grounding the chassis is required for Cisco MDS 9506 Directors that have DC power supplies, and Cisco
recommends grounding for all other chassis types, although the rack is already grounded. A grounding
pad with two threaded M4 holes is provided on the chassis for attaching a grounding lug. The ground
lug must be NRTL listed. In addition, copper conductor (wires) must be used and the copper conductor
must comply with the NEC code for ampacity.
Figure 2-14 shows the system ground location on the Cisco MDS 9506 chassis.
1ESD socket (on switch) 4Screws, M4, with square cone washers
2ESD plug 5NRTL listed grounding lug
3Grounding cable 6Close-up of grounding pad on switch
99270
2
1
3
5
4
6
Send documentation comments to mdsfeedback-doc@cisco.com.
2-27
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Grounding the Chassis
Figure 2-14 System Ground Location on the Cisco MDS 9506 Chassis
To attach the grounding lug and cable to the chassis, follow these steps:
Step 1 Locate the ESD socket on your chassis and attach the ESD plug.
Step 2 Use a wire-stripping tool to remove approximately 0.75 inches (19 mm) of the covering from the end of
the grounding cable.
Step 3 Insert the stripped end of the grounding cable into the grounding lug.
Step 4 Use the crimping tool to secure the grounding cable in the grounding lug.
Step 5 Remove the adhesive label from the grounding pad on the chassis.
Step 6 Place the grounding lug against the grounding pad so that there is solid metal-to-metal contact, and insert
the two M4 screws with washers through the holes in the grounding lug and into the grounding pad.
Ensure that the lug and cable do not interfere with other equipment.
Step 7 Prepare the other end of the grounding cable and connect it to an appropriate grounding point in your
site to ensure adequate earth ground.
1ESD socket (on switch) 4Screws, M4, with square cone washers
2ESD plug 5NRTL listed grounding lug
3Grounding cable 6Close-up of grounding pad on switch
99269
2
1
3
45
6
Send documentation comments to mdsfeedback-doc@cisco.com.
2-28
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Starting Up the Switch
Starting Up the Switch
This section provides the following information:
Connecting the Power Supplies, page 2-28
Powering Up the Switch and Verifying Component Installation, page 2-36
Warning
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution
when servicing.
Statement 1034
Caution During this procedure, wear grounding wrist straps to avoid ESD damage to the switch.
Note The 2500-W (DS-CAC-2500W) power supplies provide power according to the input voltage. If they are
in redundant rather than combined mode at 110 VAC, they may be unable to provide adequate power to
all modules present in the system. See Appendix D, “Technical Specifications.
Connecting the Power Supplies
The Cisco MDS 9513 Director uses a 6000-W power supply. The 6000-W AC power supplies for the
Cisco MDS 9513 Director are designed to provide an output power for the modules and fans. Each power
supply has two AC power connections and will provide power as follows:
One AC power connection @110 VAC = No output
Two AC power connection @110 VAC = 2900-W output
One AC power connection @ 220 VAC = 2900-W output
Two AC power connection @ 220 VAC = 6000-W output
Note Power output does not include the power used by the individual modules used in the chassis.
The Cisco MDS 9509 Director and Cisco MDS 9506 Director support both AC and DC power supplies.
The Cisco MDS 9506 Director uses power entry modules (PEMs) to provide power to its power supplies,
whether they are AC or DC (there is no power connector on the power supplies). The left PEM (as viewed
from the front of the switch) provides power to the upper power supply in the back of the Cisco MDS
9506 Director, and the right PEM provides power to the lower power supply.
This section provides the following topics:
Providing Power to an AC Power Supply for the Cisco MDS 9513 Director, page 2-29
Providing Power to an AC Power Supply for the Cisco MDS 9509 and Cisco MDS 9506 Directors,
page 2-30
Providing Power to a DC Power Supply in the Cisco MDS 9509 Director, page 2-33
Providing Power to a DC Power Supply in the Cisco MDS 9506 Director, page 2-34
Send documentation comments to mdsfeedback-doc@cisco.com.
2-29
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Starting Up the Switch
Providing Power to an AC Power Supply for the Cisco MDS 9513 Director
To provide power to an AC power supply in a Cisco MDS 9513 Director, follow these steps:
Step 1 Plug the power cable into the power supply, and tighten the screw on the cable retention device to ensure
that the cable cannot be pulled out. Each power supply has two AC power connections (as shown in
Figure 2-15).
Figure 2-15 Cable Retention on the Power Supply
Step 2 Connect the other end of the power cable to an AC power source.
Step 3 Turn the power switch to the on (|) position on the power supply.
Step 4 Verify power supply operation by checking that the power supply LEDs are in the following states:
INPUT OK LEDs are green.
FAN OK LEDs are green.
OUTPUT FAIL LED is off.
See Table 1-2 on page 1-11 for power supply LED details.
1Power switch 2Cable retention
2 2
1
144528
Send documentation comments to mdsfeedback-doc@cisco.com.
2-30
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Starting Up the Switch
Providing Power to an AC Power Supply for the Cisco MDS 9509 and Cisco MDS 9506 Directors
The basic procedure for providing power to an AC power supply is the same for both a Cisco MDS 9509
Director and a Cisco MDS 9506 Director.
Figure 2-16 shows a 2500-W AC power supply for the Cisco MDS 9509 Director.
Figure 2-16 2500-W AC Power Supply for the Cisco MDS 9509 Director
Figure 2-17 shows a 4000-W AC power supply for the Cisco MDS 9509 Director.
1AC power connection 4Captive screws
2Power cable retainer 5Power supply LEDs
3Power supply switch
Send documentation comments to mdsfeedback-doc@cisco.com.
2-31
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Starting Up the Switch
Figure 2-17 4000-W AC Power Supply for the Cisco MDS 9509 Director
Caution The following applies to AC power supplies on the Cisco MDS 9506 only:
The DS-C9506 equipment is suitable for use on TN power systems and the IT-power system connection
of Norway (max 230-V phase-phase). If connected to a 230- or 400-V IT power system, beware of
high-leakage current. Earth connection is essential before connecting power supply.
Figure 2-18 shows an AC PEM for a Cisco MDS 9506 Director.
Figure 2-18 AC PEM for Cisco MDS 9506 Director
1AC power connection 4Power supply switch
2Power supply LEDs 5Permanent power cable
3Captive screws
1Captive screws 3AC power connection
2PEM switch
94981
1 12 3
Send documentation comments to mdsfeedback-doc@cisco.com.
2-32
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Starting Up the Switch
Figure 2-19 shows a power supply for a Cisco MDS 9506 Director. The power supply has no power
connector. The power connector is provided on the PEM. The AC and DC power supplies are similar in
appearance except for the label, which indicates whether it is AC or DC.
Figure 2-19 Power Supply for Cisco MDS 9506 Director
To provide power to an AC power supply in a Cisco MDS 9509 Director or a Cisco MDS 9506 Director,
follow these steps:
Step 1 Plug the power cable into the switch as follows:
For the Cisco MDS 9509 Director, plug the power cable into the power supply and tighten the screw
on the power cable retainer to ensure that the cable cannot be pulled out.
Note The 4000-W AC power supply for the Cisco MDS 9509 Director has a permanent power cable
attached.
For the Cisco MDS 9506 Director, plug the power cable into the AC PEM on the front of the chassis.
Step 2 Connect the other end of the power cable to a power source.
Note Depending on the outlet receptacle on your power distribution unit, you may need the optional
jumper power cord to connect the Cisco MDS 9500 Series director to your outlet receptacle. See
the “Jumper Power Cord” section on page E-11.
1Power supply LEDs 2Captive screws
INPUT OK
FAN OK
OUTPUT FAIL
94996
1
2
Send documentation comments to mdsfeedback-doc@cisco.com.
2-33
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Starting Up the Switch
Providing Power to a DC Power Supply in the Cisco MDS 9509 Director
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Statement 1046
For more information on DC power supply for the MDS 9509 Director, see the “System Grounding”
section on page 2-17.
Figure 2-20 shows the 2500-W DC power supply.
Figure 2-20 2500-W DC Power Supply for the Cisco MDS 9509 Director
Note Use 90-degree C fine-stranded copper conductors for North American installations.
To provide power to a DC power supply in a Cisco MDS 9509 Director, follow these steps:
Step 1 Ensure that all power is off. Locate the circuit breaker on the panel board that services the DC circuit.
Switch the circuit breaker to the off position, and then tape the switch handle of the circuit breaker in
the off position.
1Terminal block cover 4Power supply switch
2Power supply LEDs 5Terminal block
3Captive screw
99360
INPUT
OK
FAN
OK
OUTPUT
FAIL
I
0
1
23
4
5
Send documentation comments to mdsfeedback-doc@cisco.com.
2-34
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Starting Up the Switch
Step 2 Ensure that the system (earth) ground connection is made. See the “System Grounding” section on
page 2-17.
Step 3 Turn the power switch on the power supply to off (0).
Step 4 Unfasten the two screws securing the terminal block cover and pull the cover off the terminal block.
Step 5 Connect the DC power cables to the terminal block as follows:
a. Identify the ground, negative, and positive DC cables and verify that all are copper and sized per
local and national installation requirements.
b. Strip the cable ends to allow for metal-to-metal contact.
c. Loosen the screws in the terminal block and connect the DC power cables to the terminal block in
the following order:
Ground
Negative (-)
Positive (+)
Caution The DC return connection (Negative (-)) to this system is to remain isolated from the system
frame and chassis (DC-I). Loosen the captive screw on the power supply.
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Statement 1046
d. Secure the cables in place by tightening the terminal block screws.
e. Replace the terminal block cover and fasten the two screws attaching it to the chassis.
Caution To prevent a short circuit or shock hazard after wiring the DC power supply, reinstall the
terminal block cover before restoring power to the DC circuit.
Step 6 If a second DC power supply is installed, repeat the procedure for the other power supply, using a
separate power source to provide redundancy in case of a line failure and ensuring the related circuit is
off.
Caution Leave the power to the DC circuit off until you are ready to provide power to the switch.
Step 7 If there are no other DC power cables to connect and you are ready to power the switch on, restore power
to the DC circuit by removing the tape from the circuit breaker handle and flipping the handle to on.
Providing Power to a DC Power Supply in the Cisco MDS 9506 Director
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
Send documentation comments to mdsfeedback-doc@cisco.com.
2-35
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Starting Up the Switch
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Statement 1046
For more information on DC power supply in the MDS 9506 Director, see the “System Grounding”
section on page 2-17.
Figure 2-21 shows the location of the terminal block screws and how to insert the lugs through the holes
in the front of the PEM to connect them to the screws.
Figure 2-21 DC PEM for a Cisco MDS 9506 Director
Note Use 90-degree C fine-stranded copper conductors for North American installations.
To provide power to a DC power supply in a Cisco MDS 9506 Director, follow these steps:
Step 1 Ensure that all power to the DC circuit is off by locating the circuit breaker on the panel board that
services the DC circuit. Switch the circuit breaker to the off position, and tape the switch handle of the
circuit breaker in the off position.
Step 2 Ensure that the system (earth) ground connection is made. See the “System Grounding” section on
page 2-17.
Step 3 Loosen the captive screws on the DC PEM and pull the PEM partially out of the chassis to provide access
to the PEM terminal block screws.
Step 4 Connect the positive and negative DC cables to the DC PEM using a 10-32 ring lug for each cable, as
follows:
a. Identify the positive and negative DC cables and ensure that both are copper and sized per local and
national installation requirements.
1Terminal block screws (+ and -) 4Exposed portion of positive cable
2Captive screw 5Insulated portion of negative cable
3Ring lug
99293
( ) ( )
2
3
4
1
5
( )
( )
Send documentation comments to mdsfeedback-doc@cisco.com.
2-36
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Starting Up the Switch
b. Strip the cable ends to allow for metal-to-metal contact. Insert each cable into a separate ring lug,
and crimp the lugs around the cables.
c. Insert each cable and lug into the appropriate hole in the front of the PEM and fasten the lugs to the
appropriate terminal block screws in the following order:
Negative (-)
Positive (+)
d. Secure the cables in place by tightening the terminal block screws.
Step 5 Ensure that all cable connections are secure before sliding the PEM back into the chassis, and then
tighten the captive screws.
Caution The DC return connection (Negative (-)) to this system is to remain isolated from the system
frame and chassis (DC-I). Loosen the captive screw on the power supply.
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Statement 1046
Step 6 If a second DC power supply is installed, repeat the procedure for the other DC PEM, using a separate
power source to provide redundancy in case of a line failure, and ensuring the related circuit is off.
Caution Leave the power to the DC circuits off until you are ready to provide power to the switch.
Step 7 If there are no other DC power cables to connect and you are ready to power the switch on, restore power
to the DC circuit by removing the tape from the circuit breaker handle and flipping the handle to on.
Powering Up the Switch and Verifying Component Installation
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI)
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not
operate the system unless all cards, faceplates, front covers, and rear covers are in place.
Statement
1029
Note Do not connect the MGMT 10/100 Ethernet port to the LAN until the initial switch configuration has
been performed. For instructions on configuring the switch, see the Cisco MDS 9000 Family CLI
Configuration Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide.
For instructions on connecting to the console port, see the “Connecting to the Console Port” section on
page B-2).
Send documentation comments to mdsfeedback-doc@cisco.com.
2-37
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Starting Up the Switch
To power up the switch and verify hardware operation, follow these steps:
Step 1 Verify that the faceplates of all modules are flush with the front of the chassis, and the ejector levers are
fully closed and approximately parallel to the faceplate of the module.
Step 2 Verify that any empty module slots have filler panels installed.
Step 3 Verify that both power supplies and the fan module are installed.
Step 4 If any optional CompactFlash cards are installed, verify that the ejector button is popped out.
Step 5 Check the captive screws of the power supplies, fan module, and all supervisor, switching, or services
modules, and tighten any loose captive screws.
Step 6 Ensure that the switch is adequately grounded as described in the “System Grounding” section on
page 2-17, and that the power cables are connected to outlets that have the required AC or DC power
voltages. See Appendix D, “Technical Specifications, for the required voltages.
Step 7 Power on the switch by turning the power switches on the power supplies or PEMs to the on (|) position
or restoring power to the DC circuit, as required. The switch boots automatically.
Step 8 Listen for the fans; they should begin operating as soon as the switch is powered on.
Caution Do not operate the switch without a functioning fan module except during the brief fan module
replacement procedure. The Cisco MDS 9000 Family switches can operate for only a few
minutes without a functioning fan module before they begin to overheat.
Step 9 After the switch has finished booting, verify that the LED behavior is as follows:
Fan module: Status LED is green.
Power supplies:
Input OK LED is green.
Fan OK LED is green.
Output Fail LED is off.
Supervisor, switching, or services modules:
The System LED on the supervisor module is green, indicating that all chassis environmental
monitors are reporting that the system is operational. If this LED is orange or red, then one or
more environmental monitor is reporting a problem.
The Status LED on the switching or services modules flashes orange once, remains orange
during diagnostic boot tests, then turns green when the module is operational (online). If the
system software cannot start up, this LED remains orange or turns red.
Note The LEDs for the Fibre Channel ports remain orange until the ports are enabled, and the
LED for the MGMT 10/100 Ethernet port remains off until the port is connected.
If any LEDs other than the Fibre Channel port LEDs remain orange or red after the initial boot processes
are complete, see Appendix D, “Technical Specifications.
Step 10 If a component is not operating correctly, try removing and reinstalling it. If it still does not operate
correctly, contact your customer service representative for a replacement.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-38
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules
Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical
support. If you purchased this product directly from Cisco Systems, contact Cisco Technical
Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml.
Step 11 Verify that the system software has booted and the switch has initialized without error messages. If any
problems occur, see the Cisco MDS 9000 Family Troubleshooting Guide or the Cisco MDS 9000 Family
System Messages Reference. If you cannot resolve an issue, contact your customer service
representative.
Step 12 Complete the worksheets provided in Appendix F, “Site Planning and Maintenance Records, for future
reference.
Note A setup utility automatically launches the first time you access the switch and guides you
through the basic configuration. For instructions about how to configure the switch and check
module connectivity, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco
MDS 9000 Family Fabric Manager Configuration Guide.
Removing, Installing, and Verifying Supervisor, Switching, and
Services Modules
This section provides the following information:
Removing Supervisor Modules, page 2-39
Installing Supervisor Modules, page 2-40
Removing a Caching Services Module, page 2-44
Removing Other Switching and Services Modules, page 2-45
Installing a Switching or Services Module, Including Caching Services Modules, page 2-45
Verifying Installation of Supervisor, Switching, and Services Modules, page 2-46
Removing and Installing a Crossbar Module, page 2-47
Warning
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into
beams or view directly with optical instruments.
Statement 1051
Warning
Use of controls, adjustments, or performing procedures other than those specified may result in
hazardous radiation exposure.
Statement 1057
Warning
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution
when servicing.
Statement 1034
Send documentation comments to mdsfeedback-doc@cisco.com.
2-39
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules
Caution To prevent ESD damage, wear grounding wrist straps during these procedures and handle modules by
the carrier edges only.
Note Install the Cisco MDS 9500 Series chassis in the rack before installing modules. See the “Installing the
Chassis in a Cabinet or Rack” section on page 2-6.
Note In systems with redundant supervisor modules, you can replace the faulty supervisor while the system
is operating, provided that one supervisor is always operating.
Removing Supervisor Modules
To remove a Supervisor-1 or Supervisor-2 module from the chassis, follow these steps:
Step 1 Shut down the crossbar switching fabric functionality in the supervisor module of the Cisco MDS 9509
and 9506 Directors by using the out-of-service module slot command (where slot refers to the slot
number for the Supervisor-1 or Supervisor-2 module where the integrated crossbar is located).
Step 2 Upload the current configuration to a server if the switch has only one supervisor module. For
information about the correct command, see the Cisco MDS 9000 Family CLI Configuration Guide.
Step 3 Fail over to the standby supervisor if the switch has two supervisor modules and the supervisor you are
removing is currently active. For information on how to fail over a supervisor module, see the
Cisco MDS 9000 Family CLI Configuration Guide.
Step 4 Disconnect any network interface cables attached to the module.
Step 5 Loosen the two captive screws on the module being removed.
Step 6 Remove the module from the chassis as follows:
a. Place your thumbs on the left and right ejector levers and simultaneously rotate the levers outward
to unseat the module from the backplane connector.
b. Grasp the front edge of the module and slide the module partially out of the slot. Place your other
hand under the module to support the weight of the module. Do not touch the module circuitry.
Step 7 Place the module on an antistatic mat or antistatic foam, or immediately reinstall it in another slot.
Step 8 Install a filler panel on an empty slot to keep the chassis dust-free and to maintain proper airflow through
the chassis.
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure
to hazardous voltages and currents inside the chassis; they contain electromagnetic
interference (EMI) that might disrupt other equipment; and they direct the flow of cooling
air through the chassis. Do not operate the system unless all cards, faceplates, front covers,
and rear covers are in place.
Statement 1029
Send documentation comments to mdsfeedback-doc@cisco.com.
2-40
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules
Installing Supervisor Modules
In a Cisco MDS 9513 Director, slots 7 and 8 are reserved for the Supervisor-2 modules. In the Cisco
MDS 9509 Director, slot 5 is reserved for the Supervisor-2 or Supervisor-1 module. In the Cisco MDS
9506 Director, slot 5 is reserved for the Supervisor-1 module. Slot 6 in the Cisco MDS 9509 and 9506
Directors is reserved for an additional redundant supervisor module in case the supervisor module in
slot 5 fails. See Figure 1-3 on page 1-6 and Figure 1-4 on page 1-7 for slot locations.
Supervisor-1 modules and Supervisor-2 modules cannot be used in the same switch, except for migration
purposes. Both the active and standby supervisor modules must be of the same type, either Supervisor-1
or Supervisor-2 modules. For Cisco MDS 9513 Directors, both supervisor modules must be Supervisor-2
modules.
Step 1 Before installing any modules in the chassis, Cisco recommends installing the chassis in the rack. See
the “Installing the Chassis in a Cabinet or Rack” section on page 2-6.
Step 2 Verify that there is enough clearance to accommodate any cables or interface equipment that you want
to connect to the module.
Step 3 Verify that the captive screws are tightened to 8 in-lb on all modules already installed in the chassis. This
ensures that the EMI gaskets are fully compressed and maximizes the opening space for the module
being installed.
Step 4 If a filler panel is installed, remove the two Phillips pan-head screws from the filler panel and remove
the panel. To remove a currently installed module, see the “Removing Other Switching and Services
Modules” section on page 2-45.
Step 5 Open both the ejector levers on the new or replacement module completely. (See Figure 2-22.)
Send documentation comments to mdsfeedback-doc@cisco.com.
2-41
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules
Figure 2-22 Positioning a Module in the Chassis
Step 6 Position the module in the chassis as follows:
a. Slide the module carefully into the slot until the EMI gasket along the top edge of the module
contacts the module in the slot above it and both ejector levers close to approximately 45 degrees
with respect to the front of the module (see Figure 2-23).
1Slot guides 3EMI Gasket
2EMI Gasket 4Ejector level (fully extended)
94987
4
3
5
4
66
1 2
3
4
Send documentation comments to mdsfeedback-doc@cisco.com.
2-42
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules
Figure 2-23 Clearing the EMI Gasket
b. Grasp the two ejector levers using the thumb and forefinger of each hand, and press down to create
a small 0.040-inch (1-mm) gap between the module’s EMI gasket and the module above it. (See
Figure 2-24.)
91690
1mm Amount of gap
between the
module EMI
gasket and the
module above it
5
4
6
SWITCH FABIRD MDL
WS-C6500-SFM
Press down gently
Press down gently
Send documentation comments to mdsfeedback-doc@cisco.com.
2-43
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules
Figure 2-24 Closing the Ejector Levers
Caution Do not press down too forcefully on the levers because they can bend.
c. While pressing down, simultaneously close the left and right ejector levers to fully seat the
supervisor module or switching module in the backplane connector. The ejector levers are fully
closed when they are flush with the front of the module.
Note Ensure the ejector levers are fully closed before tightening the captive screws. Failure to fully
seat the module in the backplane connector can result in error messages.
d. Tighten the two captive screws on the supervisor module or switching module to 8 in-lb.
Step 7 If you replaced the standby supervisor module in a switch that has two supervisors and is running Cisco
MDS SAN-OS Release 1.2(2a) or earlier, enable the automatic synchronization feature, which is
disabled by default. For information about the auto-sync option, see the Cisco MDS 9000 Family CLI
Configuration Guide.
Step 8 If you replaced the supervisor in a switch that does not have a second supervisor or is running Cisco
MDS SAN-OS Release 1.3(1) or later or NX-OS Release 4.1(1b), download the configuration from the
server to the nonvolatile memory of the supervisor. For more information, see the Cisco MDS 9000
Family CLI Configuration Guide.
Ejector levers flush
with module faceplate
99331
Send documentation comments to mdsfeedback-doc@cisco.com.
2-44
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules
Removing a Caching Services Module
Note A minimum of two CSMs in each fabric are required for redundancy and data backup.
Warning
Do not touch or bridge the metal contacts on the battery. Unintentional discharge of the batteries can
cause serious burns.
Statement 341
Warning
Ultimate disposal of this product should be handled according to all national laws and regulations.
Statement 1040
Caution Wait for all LEDs to turn off before removing the module from the chassis. If the LEDs are on, the
module still has power.
To remove a CSM module from the chassis, follow these steps:
Step 1 Power off the module from the CLI. For information about the correct command to use, see the
Cisco MDS 9000 Family CLI Configuration Guide.
Step 2 Ensure that the backup process has completed by verifying that all LEDs on the module have turned off.
This requires up to 10 minutes.
Step 3 Loosen the two captive screws on the module.
Step 4 Remove the module from the chassis as follows:
a. Place your thumbs on the left and right ejector levers (shown in Figure 2-22 on page 2-41) and
simultaneously rotate the levers outward to unseat the module from the backplane connector.
b. Grasp the front edge of the module and slide the module partially out of the slot. Place your other
hand under the module to support the weight of the module. Do not touch the module circuitry.
Step 5 Place the module on an antistatic mat or antistatic foam if not immediately reinstalling it in another slot.
Step 6 If the slot will remain empty, install a filler panel to keep the chassis dust-free and to maintain consistent
airflow.
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI)
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not
operate the system unless all cards, faceplates, front covers, and rear covers are in place.
Statement
1029
Send documentation comments to mdsfeedback-doc@cisco.com.
2-45
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules
Removing Other Switching and Services Modules
To remove a switching or services module from the chassis, follow these steps:
Step 1 Disconnect any network interface cables attached to the module.
Step 2 Loosen the two captive screws on the module being removed.
Step 3 Remove the module from the chassis as follows:
a. Place your thumbs on the left and right ejector levers and simultaneously rotate the levers outward
to unseat the module from the backplane connector.
b. Grasp the front edge of the module and slide the module partially out of the slot. Place your other
hand under the module to support the weight of the module. Do not touch the module circuitry.
Step 4 Place the module on an antistatic mat or antistatic foam, or immediately reinstall it in another slot.
Step 5 If the slot will remain empty, install a filler panel to keep the chassis dust-free and to maintain proper
airflow through the chassis.
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure
to hazardous voltages and currents inside the chassis; they contain electromagnetic
interference (EMI) that might disrupt other equipment; and they direct the flow of cooling
air through the chassis. Do not operate the system unless all cards, faceplates, front covers,
and rear covers are in place.
Statement 1029
Installing a Switching or Services Module, Including Caching Services
Modules
The following warning applies only to the Caching Services Module:
Warning
Do not touch or bridge the metal contacts on the battery. Unintentional discharge of the batteries can
cause serious burns.
Statement 341
To install a switching or services module in the chassis, follow these steps:
Step 1 Before installing any modules in the chassis, Cisco recommends installing the chassis in the rack. See
the “Installing the Chassis in a Cabinet or Rack” section on page 2-6.
Step 2 Before installing any switching modules, install at least one supervisor module.
Step 3 Choose a slot for the module and verify that there is enough clearance to accommodate any cables or
interface equipment that you want to connect to the module. If possible, place modules between empty
slots that contain filler panels.
Step 4 Verify that the captive screws are tightened to 8 in-lb on all modules already installed in the chassis. This
ensures that the EMI gaskets are fully compressed and maximizes the opening space for the module
being installed.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-46
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules
Step 5 If a filler panel is installed, remove the two Phillips pan-head screws from the filler panel and remove
the panel. To remove a currently installed module, see the “Removing Other Switching and Services
Modules” section on page 2-45.
Step 6 Open both the ejector levers on the new or replacement module completely. (See Figure 2-22.)
Step 7 Position the module in the chassis as follows:
a. Position the module in the slot. Ensure that you align the sides of the module carrier with the slot
guides on each side of the slot.
b. Slide the module carefully into the slot until the EMI gasket along the top edge of the module
contacts the module in the slot above it and both ejector levers close to approximately 45 degrees
with respect to the front of the module. (See Figure 2-23.)
c. Grasp the two ejector levers using the thumb and forefinger of each hand, and press down to create
a small 0.040-inch (1-mm) gap between the module’s EMI gasket and the module above it. (See
Figure 2-24.)
Caution Do not press down too forcefully on the levers because they can bend.
d. While pressing down, simultaneously close the left and right ejector levers to fully seat the
supervisor module or switching module in the backplane connector. The ejector levers are fully
closed when they are flush with the front of the module.
Note Ensure the ejector levers are fully closed before tightening the captive screws. Failure to fully
seat the module in the backplane connector can result in error messages.
e. Tighten the two captive screws on the supervisor module or switching module to 8 in-lb.
Step 8 If you replaced the standby supervisor module in a switch that has two supervisors and is running Cisco
MDS SAN-OS Release 1.2(2a) or earlier, enable the automatic synchronization feature, which is
disabled by default. For information about the auto-sync option, see the Cisco MDS 9000 Family CLI
Configuration Guide.
Step 9 If you replaced the supervisor in a switch that does not have a second supervisor or is running Cisco
MDS SAN-OS Release 1.3(1) or later or NX-OS Release 4.1(1b), download the configuration from the
server to the nonvolatile memory of the supervisor. For more information, see the Cisco MDS 9000
Family CLI Configuration Guide.
Verifying Installation of Supervisor, Switching, and Services Modules
To verify the module installation, follow these steps:
Step 1 Verify that the ejector levers of each module are fully closed (parallel to the front of the module) to
ensure that the supervisor module and all switching or services modules are fully seated in the backplane
connectors.
Step 2 Check the captive screws of each module, the power supply, and the fan module. Tighten any loose
captive screws to 8 in-lb.
Step 3 Verify that any empty module slots have filler panels installed and that the screws holding the panels in
place are tight.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-47
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules
Step 4 Turn on the power supply switches to power up the system and check the LEDs on the modules.
Note For information about how to check connectivity of modules, see the Cisco MDS 9000 Family
CLI Configuration Guide.
Removing and Installing a Crossbar Module
To remove a crossbar module from the Cisco MDS 9513 Director without compromising the integrity
and availability of SANs when Generation 1 and Generation 2 modules are combined in the chassis,
follow these steps:
Step 1 Shut down the crossbar module by using the out-of-service xbar slot command (where slot refers to the
external crossbar module slot number).
Step 2 Loosen the two captive screws on the module being removed.
Step 3 Remove the module from the chassis as follows:
a. Place your thumbs on the top and bottom ejector levers and simultaneously rotate the levers outward
to unseat the module from the midplane connector. (See Figure 2-25.)
b. Hold the front edge of the module and slide the module partially out of the slot. Do not touch the
module circuitry.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-48
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules
Figure 2-25 Captive Screws and Ejector Levers on the Crossbar Module
Step 4 Place the module on an antistatic mat or antistatic foam, or immediately reinstall it in another slot.
Step 5 If the slot will remain empty, install a filler panel to keep the chassis dust-free and to maintain proper
airflow through the chassis.
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure
to hazardous voltages and currents inside the chassis; they contain electromagnetic
interference (EMI) that might disrupt other equipment; and they direct the flow of cooling
air through the chassis. Do not operate the system unless all cards, faceplates, front covers,
and rear covers are in place.
Statement 1029
To install a crossbar module in the Cisco MDS 9513 Director, follow these steps:
Step 1 Before installing any modules, install at least one Supervisor-2 module.
1Captive screws 2Ejector levers
144526
1
1
2
2
Send documentation comments to mdsfeedback-doc@cisco.com.
2-49
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules
Step 2 Open both the ejector levers on the new or replacement module completely.
Step 3 Position the module in the chassis as follows:
a. Position the module in the slot. Ensure that you align the sides of the module carrier with the slot
guides on each side of the slot.
b. Slide the module carefully into the slot until the EMI gasket along the top edge of the module
contacts the module in the slot above it and both ejector levers close to approximately 45 degrees
with respect to the front of the module. (See Figure 2-26.)
Figure 2-26 Installing the Crossbar Module
c. Grasp the two ejector levers using the thumb and forefinger of each hand, and press down to create
a small 0.040-inch (1-mm) gap between the module's EMI gasket and the module above it.
Caution Do not press down too forcefully on the levers because they can bend.
d. While pressing down, simultaneously close the top and bottom ejector levers to completely seat the
module in the midplane connector. The ejector levers are completely closed when they are flush with
the front of the module.
147940
Send documentation comments to mdsfeedback-doc@cisco.com.
2-50
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Maintaining a Caching Services Module
Note Ensure the ejector levers are completely closed before tightening the captive screws. Failure to
completely seat the module in the backplane connector can result in error messages.
e. Tighten the two captive screws on the module to 8 in-lb.
Maintaining a Caching Services Module
Caution Maintenance must be performed only by qualified service personnel.
Note A minimum of two CSMs in each fabric are required for redundancy and data backup.
This section provides the following information:
Maintaining the Batteries on the Caching Services Module, page 2-50
Maintaining the Disk Drives on the Caching Services Module, page 2-51
Maintaining the Batteries on the Caching Services Module
The CSM batteries last approximately three years. The following message displays in the system log
when a battery fails:
Dec 5 17:14:36 sw-90.21% SVC_BATTERY-SLOT8-4-BATTERY_CAPACITY_LOW:
Battery capacity is below the required threshold.
If this message is displayed, contact your support provider for assistance. If a battery fails, the CSM must
be replaced. The other CSMs in the fabric contain the same data, and they continue providing caching
services during the replacement period.
Caution The CSM batteries are shipped fully charged and should be handled accordingly.
Warning
Do not touch or bridge the metal contacts on the battery. Unintentional discharge of the batteries can
cause serious burns.
Statement 341
Warning
Ultimate disposal of this product should be handled according to all national laws and regulations.
Statement 1040
The batteries are automatically charged on a periodic basis with an SMBus-compliant Level III smart
charger located on the CSM. The smart charger measures the charge and recharges the battery to full if
it is less than 90 percent of capacity.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-51
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
The batteries are also automatically reconditioned on a periodic basis, one battery at a time. During
reconditioning all power is drained from the battery and the battery is completely recharged, requiring
approximately 6 hours. The battery status LED flashes green during the reconditioning.
Maintaining the Disk Drives on the Caching Services Module
You see a message in the system log when a disk drive requires replacement. If you see this message,
contact your support provider for assistance.
If a disk drive fails, the CSM must be replaced. The other CSM(s) in the fabric contain the same data,
and they continue providing caching services during the replacement period.
Removing and Installing a Power Supply or PEM
This section provides the following information:
Removing and Installing the Power Supplies on the Cisco MDS 9513 Director, page 2-52
Removing an AC Power Supply from the Cisco MDS 9513 Director, page 2-52
Installing an AC Power Supply in the Cisco MDS 9513 Director, page 2-54
Removing an AC Power Supply from the Cisco MDS 9509 Director, page 2-56
Installing an AC Power Supply in the Cisco MDS 9509 Director, page 2-57
Removing a DC Power Supply from the Cisco MDS 9509 Director, page 2-61
Installing a DC Power Supply in the Cisco MDS 9509 Director, page 2-62
Removing and Installing the PEMs on the Cisco MDS 9506 Director, page 2-64
Removing an AC or DC Power Supply from the Cisco MDS 9506 Director, page 2-67
Installing an AC or DC Power Supply in the Cisco MDS 9506 Director, page 2-67
A flat-blade or number 2 Phillips-head screwdriver is required to perform these procedures.
Warning
Voltage is present on the backplane when the system is operating. To reduce risk of an electric shock,
keep hands and fingers out of the power supply bays and backplane areas.
Statement 166
Warning
Power supply captive installation screws must be tight to ensure protective grounding continuity.
Statement 289
Caution Use both hands to install and remove power supplies. Each DC power supply for the
Cisco MDS 9500 Series weighs between 22 lb (9.9 kg) and 28 lb (12.6 kg).
Note You can replace the faulty power supply while the system is operating if the other power supply is
functioning.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-52
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Removing and Installing the Power Supplies on the Cisco MDS 9513 Director
The Cisco MDS 9513 power supplies are located at the rear of the chassis. The physical position of the
chassis in a rack will determine how you handle the power supply when removing or installing.
Removing an AC Power Supply from the Cisco MDS 9513 Director
Warning
Voltage is present on the backplane when the system is operating. To reduce risk of an electric shock,
keep hands and fingers out of the power supply bays and backplane areas.
Statement 166
To remove an AC power supply from the Cisco MDS 9513 Director, follow these steps:
Step 1 Turn the power switch on the power supply to the off (0) position. There is an internal lock mechanism
that prevents you from removing the power supply if it is not set to the off position.
Step 2 Disconnect the power cable(s) from the power source.
Step 3 Loosen the screw on the cable retention device and disconnect the power cable from the power supply.
Figure 2-27 Cable Retention Device on the 6000W Power Supply
Step 4 Loosen all four 6-32 panel fasteners at the corners of the power supply.
147966
Cable retention
device
Send documentation comments to mdsfeedback-doc@cisco.com.
2-53
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Caution Use both hands to install and remove power supplies. Each power supply weighs 34.2 lbs (15.5
kg).
Step 5 Grasp the power supply handles and slide the power supply partially out of the chassis, about four to five
inches. (See Figure 2-28.)
Step 6 If the power supply is at your waist or chest level, place your other hand underneath the power supply
and slide the power supply completely out of the chassis. Use the two front handles if you are
comfortable doing so.
Note There is a handle at the top rear of the power supply you can also use to lift the power supply
out of the chassis.
Figure 2-28 Handling a Power Supply for the Cisco MDS 9513 Director
Step 7 If the power supply is above your waist or chest height, use the lower front handle on the face plate and
the other hand underneath the power supply. Assure adequate support with both hands on the unit at the
designated support points, and slowly pull the power supply out of the chassis so that the weight of the
unit will be fully supported once it is removed.
144529
Send documentation comments to mdsfeedback-doc@cisco.com.
2-54
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Caution To avoid damage to the panel fasteners, do not place the power supply down on the perforated ends. Place
the power supply down on the flat sheet metal sides or on the two brackets found on the rear of the power
supply.
Step 8 Install a power supply filler panel over the opening and tighten the captive screws to 8 in-lb if the power
supply bay that has to remain empty.
Installing an AC Power Supply in the Cisco MDS 9513 Director
Caution Use both hands to install and remove power supplies. Each Cisco MDS 9513 AC power supply weighs
up to 34.2 lb (15.5 kg).
Caution To avoid damage to the panel fasteners, do not place the power supply down on the perforated ends. Place
the power supply down on the flat sheet metal sides or on the two brackets found on the rear of the power
supply.
To install an AC power supply in the Cisco MDS 9513 Director, follow these steps:
Step 1 Ensure that the system (earth) ground connection has been made. See the “System Grounding” section
on page 2-17.
Step 2 If a filler panel is installed, remove the filler panel from the power supply bay by loosening the captive
screw.
Step 3 Ensure that the power switch is in the off (0) position on the power supply you are installing. (See
Figure 2-29.)
Send documentation comments to mdsfeedback-doc@cisco.com.
2-55
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Figure 2-29 AC Power Supply for the Cisco MDS 9513 Director
Step 4 Grasp the power supply handles, one with each hand. Orient the power supply and align it with the bay.
Note There is a handle at the top rear of the power supply you can also use to tilt the power supply
into the bay.
Step 5 Slide the power supply into the power supply bay. Ensure that the power supply is fully seated in the bay.
Step 6 Secure all four 6-32 panel fasteners and tighten to 8 in-lbs.
Step 7 Plug the power cable into the power supply, and tighten the screw on the cable retention device to ensure
that the cable cannot be pulled out.
Step 8 Connect the other end of the power cable to an AC power source.
Step 9 Turn the power switch to the on (|) position on the power supply.
Step 10 Verify power supply operation by checking that the power supply LEDs are in the following states:
INPUT OK LEDs are green.
FANs OK LED is green.
OUTPUT FAIL LED is off.
1Power supply switch 2Power cable retainer
2 2
1
144528
Send documentation comments to mdsfeedback-doc@cisco.com.
2-56
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
See Table 1-2 on page 1-11 for power supply LED details.
Removing an AC Power Supply from the Cisco MDS 9509 Director
The procedure for removing an AC power supply from the Cisco MDS 9509 Director is the same for the
4000-W, 3000-W, and 2500-W power supplies, except the power cable for the 4000-W power supply is
hard wired to the power supply.
Warning
Voltage is present on the backplane when the system is operating. To reduce risk of an electric shock,
keep hands and fingers out of the power supply bays and backplane areas.
Statement 166
To remove an AC power supply from the Cisco MDS 9509 Director, follow these steps:
Step 1 Turn the power switch on the power supply to the off (0) position. Turning the power switch off also
unlocks the power supply from the chassis.
Step 2 Disconnect the power cable from the power source.
Step 3 Loosen the screw on the cable retention device and disconnect the power cable from the power supply
being removed.
Note The AC power cable for the 4000-W power supply is hardwired and cannot be removed from the
power supply.
Step 4 Loosen the captive screw.
Caution Use both hands to install and remove power supplies. Each Cisco MDS 9500 Series AC power
supply weighs between 22 lb (9.9 kg) and 28 lb (12.6 kg).
Step 5 Grasp the power supply handle with one hand, and slide the power supply partially out of the chassis.
Place your other hand underneath the power supply, as shown in Figure 2-30, and slide the power supply
completely out of the chassis.
Step 6 If the power supply bay is to remain empty, install a power supply filler panel over the opening, and
tighten the captive screw to 8 in-lb.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-57
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Figure 2-30 Handling a Power Supply for the Cisco MDS 9509 Director
Installing an AC Power Supply in the Cisco MDS 9509 Director
The procedure for installing an AC power supply in the Cisco MDS 9509 Director is the same for the
4000-W, 3000-W, and 2500-W power supplies, except that the power cable for the 4000-W power supply
is hardwired to the power supply.
Caution Use both hands to install and remove power supplies. Each Cisco MDS 9509 AC power supply weighs
up to 28 lb (12.6 kg). The 4000-W and 2500-W power supplies weigh up to 28 lb (12.6 kg). The 3000-W
power supply weighs up to 24 lb (11 kg).
To install an AC power supply in the Cisco MDS 9509 Director, follow these steps:
Step 1 Ensure that the system (earth) ground connection has been made. See the “System Grounding” section
on page 2-17.
Step 2 If a filler panel is installed, remove the filler panel from the power supply bay by loosening the captive
screw.
91687
Send documentation comments to mdsfeedback-doc@cisco.com.
2-58
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Step 3 Ensure that the power switch is in the off (0) position on the power supply you are installing. See
Figure 2-33 and Figure 2-31 for the location of the switch.
Figure 2-31 4000-W AC Power Supply for the Cisco MDS 9509 Director
1AC power connection 4Power supply switch
2Power supply LEDs 5Permanent power cable
3Captive screw
Send documentation comments to mdsfeedback-doc@cisco.com.
2-59
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Figure 2-32 3000-W AC Power Supply for the Cisco MDS 9509 Director
1AC power connection 4Power supply LEDs
2Power cable 5Captive screws
3Power supply switch
144986
1
2
3
4
5 5
Send documentation comments to mdsfeedback-doc@cisco.com.
2-60
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Figure 2-33 2500-W AC Power Supply for the Cisco MDS 9509 Director
Step 4 Grasp the power supply handle with one hand, place your other hand underneath the power supply, and
slide the power supply into the power supply bay. Ensure that the power supply is fully seated in the bay.
Step 5 Tighten the power supply captive screw to 8 in-lb.
Step 6 Plug the power cable into the power supply, and tighten the screw on the cable retention device to ensure
that the cable cannot be pulled out.
Note The AC power cable for the 4000-W power supply is hardwired to the power supply.
Step 7 Connect the other end of the power cable to an AC power source.
Step 8 Turn the power switch to the on (|) position on the power supply. Turning the power switch on also locks
the power supply in the bay.
Step 9 Verify power supply operation by checking that the power supply LEDs are in the following states:
INPUT OK LED is green.
FAN OK LED is green.
OUTPUT FAIL LED is off.
If the LEDs indicate a power problem, see the Cisco MDS 9000 Family Troubleshooting Guide. If you
cannot resolve an issue, contact your customer service representative.
1AC power connection 4Captive screw
2Power cable retainer 5Power supply LEDs
3Power supply switch
Send documentation comments to mdsfeedback-doc@cisco.com.
2-61
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Removing a DC Power Supply from the Cisco MDS 9509 Director
The DC power supply for the Cisco MDS 9509 Director is 2500 W.
Note The DC return connection to this system is to remain isolated from the system frame and chassis (DC-I).
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
To remove a DC power supply from the Cisco MDS 9509 Director, follow these steps:
Step 1 Ensure that all power is off by locating the circuit breaker on the panel board that services the DC circuit.
Switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off
position.
Step 2 Remove the two screws securing the terminal block cover and slide the cover off the terminal block. (See
Figure 2-34.)
Step 3 Disconnect the DC cables from the terminal block in the following order:
Positive (+)
Negative (-)
Ground
Caution The DC return connection (Negative (-)) to this system is to remain isolated from the system
frame and chassis (DC-I). Loosen the captive screw on the power supply.
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Statement 1046
Send documentation comments to mdsfeedback-doc@cisco.com.
2-62
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Figure 2-34 Front Panel for the DC Power Supply of the Cisco MDS 9509 Director
Caution Use both hands to install and remove power supplies. Each Cisco MDS 9500 Series DC power
supply weighs between 22 lb (9.9 kg) and 28 lb (12.6 kg).
Step 4 Grasp the power supply handle with one hand and slide the power supply halfway out of the chassis.
Place your other hand underneath the power supply, as shown in Figure 2-34, and slide the power supply
completely out of the chassis.
Step 5 If the power supply bay is to remain empty, install a power supply filler panel over the opening, and
tighten the captive screw to 8 in-lb.
Installing a DC Power Supply in the Cisco MDS 9509 Director
The DC power supply for the Cisco MDS 9509 Director is 2500 W.
Note The DC return connection to this system is to remain isolated from the system frame and chassis (DC-I).
To install a DC power supply in the Cisco MDS 9509 Director, follow these steps:
Step 1 Ensure that all power is off by locating the circuit breaker on the panel board that services the DC circuit.
Switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off
position.
1Terminal block cover 4Power supply switch
2Power supply LEDs 5Terminal block
3Captive screw
99360
INPUT
OK
FAN
OK
OUTPUT
FAIL
I
0
1
23
4
5
Send documentation comments to mdsfeedback-doc@cisco.com.
2-63
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Step 2 Ensure that the system (earth) ground connection has been made. See the “System Grounding” section
on page 2-17.
Step 3 Grasp the power supply handle with one hand, place your other hand underneath the power supply, and
slide the power supply into the power supply bay, ensuring that it is fully seated in the bay.
Step 4 Tighten the captive screw on the power supply to 8 in-lb.
Step 5 Remove the two screws securing the terminal block cover and slide the cover off of the terminal block.
Note Use 90°C copper conductors for North American installations.
Step 6 Loosen the screws inside the terminal block and attach the DC cables to the screws. The wire must be
copper, and sized per local and national installation requirements.
Step 7 Connect the DC cables to the terminal block in the following order:
Ground
Negative (-)
Positive (+)
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Statement 1046
Caution The DC return connection (Negative (-)) to this system is to remain isolated from the system
frame and chassis (DC-I).
Step 8 Reinstall the terminal block cover after ensuring that all cable connections are secure and tighten the
screws holding the terminal block to the power supply.
Caution Reinstall the terminal block cover to prevent a short circuit or shock hazard.
Caution In a system with dual power supplies, connect each power supply to a separate source. In case
of a line failure, the second source will most likely still be available.
Step 9 Remove the tape from the circuit breaker switch handle and provide power by moving the handle to the
on (|) position.Turning the power switch on also locks the power supply in the chassis.
Step 10 Verify power supply operation by checking that the power supply LEDs are in the following states:
INPUT OK LED is green.
FAN OK LED is green.
Output fail LED is off.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-64
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Removing and Installing the PEMs on the Cisco MDS 9506 Director
Note For instructions on connecting the cables to the PEMs, see the “Connecting the Power Supplies” section
on page 2-28.
The Cisco MDS 9506 Director uses PEMs to provide an input power connection on the front of the
chassis. In addition, the PEM provides current protection, surge and EMI suppression, and filtering
functions. An AC PEM is required for each AC power supply, and a DC PEM for each DC power supply.
The PEM that is on the left when viewed from the front of the switch (PEM 1) connects the site power
source to power supply 1 (upper power supply); the PEM on the right (PEM 2) connects the site power
source to power supply 2 (lower power supply).
Note You need a flat-blade or number 2 Phillips-head screwdriver to perform these procedures.
Removing an AC PEM
To remove an AC PEM from a Cisco MDS 9506 chassis, follow these steps:
Step 1 Remove power from the PEM by pressing the power switch to off (0).
Step 2 Loosen the captive screws and pull the PEM of the chassis, supporting the PEM from underneath.
Step 3 If the PEM bay is to remain empty, install a filler panel over the opening and tighten the captive screws
to 8 in-lb.
Removing a DC PEM
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
To remove a DC PEM from a Cisco MDS 9506 chassis, follow these steps:
Step 1 Ensure that all power is off by locating the circuit breaker on the panel board that services the DC circuit.
Switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off
position.
Step 2 Loosen the captive screws and pull the DC PEM from the chassis, holding it by the edges.
Step 3 Remove the cables from the DC PEM by removing the terminal block screws, and then removing the
ring lugs from the screws. See Figure 2-35 for the location of the terminal block screws.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-65
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Figure 2-35 Connecting or Disconnecting the DC PEM
Step 4 If the PEM bay is to remain empty, install a PEM filler panel over the opening and tighten the captive
screws to 8 in-lb.
1PEM terminal block screws (+ and -) 4Stripped portion of positive cable
2Captive screw 5Insulated portion of negative cable
3Ring lug
99293
( ) ( )
2
3
4
1
5
( )
( )
Send documentation comments to mdsfeedback-doc@cisco.com.
2-66
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Installing an AC PEM
To install an AC PEM in a Cisco MDS 9506 chassis, follow these steps:
Step 1 Ensure that the system (earth) ground connection has been made. See the “System Grounding” section
on page 2-17.
Step 2 If a filler panel is installed, remove it from the PEM bay by loosening the captive screws and pulling it
from the chassis.
Step 3 Slide the PEM into the PEM bay, ensuring that the PEM is fully seated in the bay.
Step 4 Tighten the PEM captive screws to 8 in-lb.
Step 5 Provide power to the PEM as described in the “Providing Power to an AC Power Supply for the Cisco
MDS 9509 and Cisco MDS 9506 Directors” section on page 2-30.
Caution In a system with dual power supplies, connect each power supply to a separate power source.
In case of a power source failure, the second source will most likely still be available.
Step 6 Verify PEM and power supply operation by checking the power supply LED states in the back of the
chassis:
INPUT OK LED is green.
FAN OK LED is green.
OUTPUT FAIL LED is off.
Installing a DC PEM
To install a DC PEM in a Cisco MDS 9506 chassis, follow these steps:
Step 1 Ensure that the system (earth) ground connection has been made. See the “System Grounding” section
on page 2-17.
Step 2 If a filler panel is installed, remove it from the PEM bay by loosening the captive screws and pulling it
from the chassis.
Step 3 Attach the DC power cables to the PEM as described in “Providing Power to a DC Power Supply in the
Cisco MDS 9506 Director” section on page 2-34.
Step 4 Slide the PEM into the PEM bay, ensuring that the PEM is fully seated in the bay.
Step 5 Tighten the PEM captive screws to 8 in-lb.
Caution In a system with dual power supplies, connect each power supply to a separate power source.
In case of a power source failure, the second source will most likely still be available.
Step 6 Verify PEM and power supply operation by checking the power supply LED states in the back of the
chassis:
INPUT OK LED is green.
FAN OK LED is green.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-67
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
OUTPUT FAIL LED is off.
Removing an AC or DC Power Supply from the Cisco MDS 9506 Director
The procedure for removing a Cisco MDS 9506 power supply is the same for AC and DC power supplies.
To remove an AC or DC power supply from the Cisco MDS 9506 Director, follow these steps:
Step 1 Remove power from the PEM that corresponds to the power supply as follows:
If the PEM is AC, press the power switch to off (0).
If the PEM is DC, follow the instructions in the “Removing a DC PEM” section on page 2-64.
Step 2 Loosen the captive screws on the power supply.
Step 3 Grasp both power supply handles as shown in Figure 2-36 and slide the power supply completely out of
the chassis.
Figure 2-36 Handling a Power Supply for the Cisco MDS 9506 Director
Step 4 If the power supply bay is to remain empty, install a filler panel over the opening and tighten the captive
screws to 8 in-lb.
Installing an AC or DC Power Supply in the Cisco MDS 9506 Director
The procedure for installing a Cisco MDS 9506 power supply is the same for AC and DC power supplies.
To install an AC or DC power supply in the Cisco MDS 9506 Director, follow these steps:
91714
INPUT OK
FAN OK
OUTPUT FAIL
INPUT OK
FAN OK
OUTPUT FAIL
Send documentation comments to mdsfeedback-doc@cisco.com.
2-68
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Fan Modules
Step 1 Ensure that the system (earth) ground connection has been made. See the “System Grounding” section
on page 2-17.
Step 2 If a filler panel is installed, remove it from the power supply bay by loosening the captive screws and
pulling the filler panel out of the bay.
Step 3 Grasp both power supply handles and slide the power supply into the power supply bay, ensuring that
the power supply is fully seated in the bay.
Step 4 Tighten the captive screws on the power supply to 8 in-lb.
Step 5 Provide power to the PEM as described in the “Connecting the Power Supplies” section on page 2-28.
Caution In a system with dual power supplies, connect each power supply to a separate power source.
In case of a power source failure, the second source will most likely still be available.
Step 6 Verify power supply operation by checking that the power supply LEDs are in the following states:
INPUT OK LED is green.
FAN OK LED is green.
OUTPUT FAIL LED is off.
Removing and Installing Fan Modules
The fan module is designed to be removed and replaced while the system is operating without presenting
an electrical hazard or damage to the system, provided the replacement is performed promptly.
The Cisco MDS 9513 fan module has 15 fans with an abrupt stop-to-fan rotation safety feature after
power is disconnected or the fan tray is removed from the midplane. The Cisco MDS 9506 fan module
has six fans and the Cisco MDS 9509 fan module has nine fans. The removal procedures differ slightly
while the installation procedures are the same for all types of fan modules.
You need a flat-blade or number 2 Phillips screwdriver to perform these procedures.
Note Because the fan modules are located on the left side of the Cisco MDS 9500 Series, Cisco recommends
guiding the cables for the system out of the right side of the chassis.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-69
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Fan Modules
Caution The Cisco MDS 9000 Family switches have internal temperature sensors that are capable of shutting
down the system if the temperature at different points within the chassis exceed certain safety thresholds.
To be effective, the temperature sensors require the presence of airflow; therefore, in the event a fan
module is removed from the chassis, the Cisco MDS 9000 Family switches will be shut down after five
minutes to prevent potentially undetectable overheating. However, the switches will be shut down sooner
if the higher-level temperature threshold is exceeded.
This section includes the following topics:
Removing a Front Fan Module on the Cisco MDS 9513 Director, page 2-69
Installing a Front Fan Module on the Cisco MDS 9513 Director, page 2-70
Removing the Crossbar Module Fan Tray, page 2-71
Installing the Crossbar Module Fan Tray, page 2-72
Removing a Front Fan Module on the Cisco MDS 9509 Director, page 2-73
Installing a Front Fan Module on the Cisco MDS 9509 Director, page 2-73
Removing a Front Fan Module on the Cisco MDS 9506 Director, page 2-74
Installing a Front Fan Module on the Cisco MDS 9506 Director, page 2-74
Removing a Front Fan Module on the Cisco MDS 9513 Director
To remove the fan module from the Cisco MDS 9513 director, follow these steps:
Step 1 Push the button on the top fan module latch to release the fan module from the midplane. Repeat this on
the bottom fan module latch.
Step 2 Grasp the fan module with both hands and pull it outward; rock it gently, if necessary, to unseat the power
connector from the backplane.
Step 3 Pull the fan module clear of the chassis. (See Figure 2-36.)
Send documentation comments to mdsfeedback-doc@cisco.com.
2-70
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Fan Modules
Figure 2-37 Removing the Fan Module for the Cisco MDS 9513 Director
Warning
When removing the fan tray, keep your hands and fingers away from the spinning fan blades. Let the
fan blades completely stop before you remove the fan tray.
Statement 258
Installing a Front Fan Module on the Cisco MDS 9513 Director
To install a front fan module on the Cisco MDS 9513 Director, follow these steps:
Step 1 Hold the fan module so that the Fan Status LED is at the top. (See Figure 2-39.)
Step 2 Place the fan module into the front chassis cavity so it rests on the chassis, lift the fan module up slightly
to align the top and bottom chassis guides, then push the fan module into the chassis until it seats in the
backplane and the captive screws make contact with the chassis. The fan module will just snap in.
Step 3 If the switch is powered on, listen for the fans; you should immediately hear them operating. If you do
not hear them, ensure that the fan module is inserted completely in the chassis and the outside surface
of the fan module is flush with the outside surface of the chassis.
Step 4 Verify that the Fan Status LED is green. If the LED is not green, one or more fans are faulty. If this
occurs, contact your customer service representative for a replacement part.
144599
Send documentation comments to mdsfeedback-doc@cisco.com.
2-71
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Fan Modules
Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical
support. If you purchased this product directly from Cisco Systems, contact Cisco Technical
Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml.
Removing the Crossbar Module Fan Tray
The crossbar module fan tray is designed to be removed and replaced while the system is operating
without presenting an electrical hazard or damage to the system, provided the replacement is performed
promptly. The crossbar module fan tray is used only in the Cisco MDS 9513 Director. It is installed at
the rear of the chassis and plugs into the back side of the midplane just above the crossbar modules.
To remove a crossbar module fan tray, follow these steps:
Step 1 Loosen the two captive screws on the fan tray.
Step 2 Hold the two captive screws and pull the fan tray out of the chassis using both hands.
Step 3 Take one hand and hold the face of the fan tray while supporting it with the other hand.
Step 4 Pull the fan module clear of the chassis. (See Figure 2-37.)
Send documentation comments to mdsfeedback-doc@cisco.com.
2-72
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Fan Modules
Figure 2-38 Removing a Crossbar Module Fan Tray
Installing the Crossbar Module Fan Tray
To install a crossbar module fan tray, follow these steps:
Step 1 Remove the crossbar module fan tray from the bag if necessary.
Step 2 Orient the crossbar module fan tray in the chassis as follows:
a. Position the module in the slot. (See Figure 2-38.)
b. Slide the module carefully into the slot until the the fan tray is fully inserted into the chassis.
c. Tighten the two captive screws on the crossbar module fan tray to 8 in-lb screws.
144600
Send documentation comments to mdsfeedback-doc@cisco.com.
2-73
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Fan Modules
Removing a Front Fan Module on the Cisco MDS 9509 Director
To remove a fan module from the Cisco MDS 9509 or 9506 switch, follow these steps:
Step 1 Loosen the two captive screws on the fan module (see Figure 2-39) by turning them counterclockwise;
use a flat-blade or number 2 Phillips screwdriver, if required.
Step 2 Grasp the fan module with both hands and pull it outward; rock it gently, if necessary, to unseat the power
connector from the backplane.
Step 3 Pull the fan module clear of the chassis.
Figure 2-39 Handling the Fan Module for the Cisco MDS 9509 Director
Installing a Front Fan Module on the Cisco MDS 9509 Director
To install a front fan module on the Cisco MDS 9509 Director, follow these steps:
Step 1 Hold the fan module so that the Fan Status LED is at the top. (See Figure 2-39.)
Step 2 Place the fan module into the front chassis cavity so it rests on the chassis, lift the fan module up slightly
to align the top and bottom chassis guides, then push the fan module into the chassis until it seats in the
backplane and the captive screws make contact with the chassis.
91685
Send documentation comments to mdsfeedback-doc@cisco.com.
2-74
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Fan Modules
Step 3 Tighten the captive screws to 8 in-lb.
Step 4 If the switch is powered on, listen for the fans; you should immediately hear them operating. If you do
not hear them, ensure that the fan module is inserted completely in the chassis and the outside surface
of the fan module is flush with the outside surface of the chassis.
Step 5 Verify that the Fan Status LED is green. If the LED is not green, one or more fans are faulty. If this
occurs, contact your customer service representative for a replacement part.
Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical
support. If you purchased this product directly from Cisco Systems, contact Cisco Technical
Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml.
Removing a Front Fan Module on the Cisco MDS 9506 Director
To remove a fan module from the Cisco MDS 9506 Director, follow these steps:
Step 1 Loosen the two captive screws on the fan module (see Figure 2-39) by turning them counterclockwise;
use a flat-blade or number 2 Phillips screwdriver, if required.
Step 2 Grasp the fan module with both hands and pull it outward; rock it gently, if necessary, to unseat the power
connector from the backplane.
Step 3 Pull the fan module clear of the chassis.
Installing a Front Fan Module on the Cisco MDS 9506 Director
To install a front fan module on the Cisco MDS 9506 Director, follow these steps:
Step 1 Hold the fan module so that the Fan Status LED is at the top.
Step 2 Place the fan module into the front chassis cavity so it rests on the chassis, lift the fan module up slightly
to align the top and bottom chassis guides, then push the fan module into the chassis until it seats in the
backplane and the captive screws make contact with the chassis.
Step 3 Tighten the captive screws to 8 in-lb.
Step 4 If the switch is powered on, listen for the fans; you should immediately hear them operating. If you do
not hear them, ensure that the fan module is inserted completely in the chassis and the outside surface
of the fan module is flush with the outside surface of the chassis.
Step 5 Verify that the Fan Status LED is green. If the LED is not green, one or more fans are faulty. If this
occurs, contact your customer service representative for a replacement part.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-75
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing CompactFlash Cards
Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical
support. If you purchased this product directly from Cisco Systems, contact Cisco Technical
Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml.
Removing and Installing CompactFlash Cards
The supervisor module has one slot for an optional CompactFlash card. You can use this slot to install
additional flash memory for storing and running software images and configuration files, or to serve as
an I/O device.
Caution Only use CompactFlash devices that are certified for use with Cisco MDS switches and are formatted
using Cisco MDS switches. Using CompactFlash devices that are uncertified or are formatted using
other platforms may result in errors. For information on formatting the external CompactFlash, see the
Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS 9000 Family Fabric Manager
Configuration Guide.
You can install and remove the CompactFlash card with the switch powered on.
Caution Do not remove the CompactFlash card while the access LED light is on or the file may be corrupted.
This section describes how to install and remove a CompactFlash card. For additional information about
the CompactFlash card, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS
9000 Family Fabric Manager Configuration Guide.
Removing a CompactFlash Card
To remove a CompactFlash card, follow these steps:
Step 1 Verify that no operations are in progress by verifying that the LED is off.
Step 2 Press the ejector button until the card is free of the connector at the back.
Step 3 Remove the card from the slot and place it in an antistatic bag.
Send documentation comments to mdsfeedback-doc@cisco.com.
2-76
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Clock Modules
Installing a CompactFlash Card
To install a CompactFlash card, follow these steps:
Step 1 Position the CompactFlash card with the connector end of the card toward the slot. The connector end
of the card is on the opposite side of the write-protection switch.
Step 2 Insert the card into the slot until the card is firmly seated in the connector at the back of the slot and the
ejector button pops out toward you.
Caution The card does not insert all the way inside the slot; a portion of the card remains outside the
slot. Do not attempt to force the card past this point or you could damage the connector pins.
Removing and Installing Clock Modules
The Cisco MDS 9500 Series includes one or more clock modules that are accessible from the back of
the chassis. In the unlikely event of a clock module failure, Cisco recommends that the failed clock
module be replaced during a maintenance window. The Cisco MDS 9513 and 9509 Directors have two
field-replacable clock modules. The Cisco MDS 9506 Director has one field-replacable clock module.
A separate procedure is provided for each type of director:
Removing a Clock Module from the Cisco MDS 9513 Director, page 2-77
Installing a Clock Module into the Cisco MDS 9513 Director, page 2-79
Removing a Clock Module from the Cisco MDS 9509 Director, page 2-80
Installing a Clock Module into the Cisco MDS 9509 Director, page 2-83
Removing a Clock Module from the Cisco MDS 9506 Director, page 2-83
Installing a Clock Module into the Cisco MDS 9506 Director, page 2-86
Before installing the clock module, check the contents of your kit. Table 2-5 lists the contents of the
clock module replacement kit, part number DS-C9513-CL.
These tools are required to remove or install a clock module:
Number 2 Phillips screwdriver
Your own ESD-prevention equipment or the disposable grounding wrist strap included with all
upgrade kits, field-replaceable units (FRUs), and spares
Ta b l e 2-5 Contents of Cisco MDS 9513 Clock Module Replacement Kits
Quantity Part Description
1Cisco MDS 9513 clock module
1Disposable ESD wrist strap
Send documentation comments to mdsfeedback-doc@cisco.com.
2-77
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Clock Modules
Removing a Clock Module from the Cisco MDS 9513 Director
Clock modules are connected to the rear of the Cisco MDS 9513 Director and are not visible as they are
located on the inside of the cover panel. Figure 2-40 shows the clock modules in a rear view of the Cisco
MDS 9513 Director with the back panel removed. Cisco recommends that the failed clock module be
replaced during a maintenance window.
Figure 2-40 Clock Module Location on the Cisco MDS 9513 Director (Rear View)
Caution Always wear an ESD wrist strap when handling modules or coming into contact with internal
components.
To remove the clock module, follow these steps:
Step 1 Note which clock module you are removing. Use the show environment clock command to verify which
is active and standby.
Step 2 Use a Phillips screwdriver to remove the eight back panel screws from the rear of the Cisco MDS 9513
Director chassis.
1Clock A (CLK A) 2Clock B (CLK B)
144601
1 2
Send documentation comments to mdsfeedback-doc@cisco.com.
2-78
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Clock Modules
Note Note the position and orientation of the clock module before you remove it from the director
chassis because you must install the new clock module in the same position.
Step 3 Verify the LEDs on the clock modules.
Step 4 Disconnect and gently remove the module, placing it on an antistatic mat or foam. (See Figure 2-41.)
Figure 2-41 Clock Module Replacement on the Cisco MDS 9513 Director (Rear View)
Step 5 Repeat Step 3 and Step 4 to remove any additional clock modules.
144602
Component
side
Sheet metal
side
Send documentation comments to mdsfeedback-doc@cisco.com.
2-79
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Clock Modules
Installing a Clock Module into the Cisco MDS 9513 Director
Caution Always wear an ESD wrist strap when handling modules or coming into contact with internal
components.
To install the clock module, follow these steps:
Step 1 Remove the new clock module from the antistatic bag.
Step 2 Hold the module with the backplane connectors away from you and the circuit board facing the right.
Figure 2-42 Clock Module for the Cisco MDS 9513 Director
Step 3 Carefully press the module onto the two matching connectors on the backplane.
Note You must install the new clock module in the same position that you removed it.
Step 4 Repeat Step 1 through Step 4 to install any additional clock modules.
Step 5 Replace the back panel safety cover using the eight screws.
Step 6 Provide power to the power supplies as described in the “Connecting the Power Supplies” section on
page 2-28.
Caution In a system with dual power supplies, connect each power supply to a separate power source.
In case of a power source failure, the second source will most likely still be available.
Step 7 Verify power supply operation by checking that the power supply LEDs are in the following states:
INPUT OK LED is green.
FAN OK LED is green.
147965
Send documentation comments to mdsfeedback-doc@cisco.com.
2-80
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Clock Modules
OUTPUT FAIL LED is off.
Removing a Clock Module from the Cisco MDS 9509 Director
Before installing the clock module, check the contents of your kit. Table 2-6 lists the contents of the
clock module replacement kit, part number DS-C9509-CL=.
These tools are required to remove or install a clock module:
Number 1 Phillips screwdriver
Your own ESD-prevention equipment or the disposable grounding wrist strap included with all
upgrade kits, field-replaceable units (FRUs), and spares
Clock modules are connected to the rear of the Cisco MDS 9509 Director using two connectors.
Figure 2-43 shows the clock modules in a rear view of the Cisco MDS 9509 Director with the back panel
removed.
Figure 2-43 Clock Module Location on the Cisco MDS 9509 Director (Rear View)
Ta b l e 2-6 Contents of Cisco MDS 9509 Clock Module Replacement Kits
Quantity Part Description
1Cisco MDS 9509 clock module
12 M3 x 6-mm Phillips pan-head screws
1Disposable ESD wrist strap
Cisco MDS 9509
1
2
120141
Send documentation comments to mdsfeedback-doc@cisco.com.
2-81
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Clock Modules
Caution Always wear an ESD wrist strap when handling modules or coming into contact with internal
components.
To remove the clock module, follow these steps:
Step 1 Remove power from both power supplies as follows:
If the power supply is AC, press the power switch to off (0) and remove the power cable.
If the power supply is DC, follow the instructions in the “Providing Power to a DC Power Supply in
the Cisco MDS 9509 Director” section on page 2-33.
Caution Before working on a system that has an on/off switch, turn off the power and unplug the power
cord.
Step 2 Use a Phillips screwdriver to remove the 18 back panel screws from the rear of the Cisco MDS 9509
Director chassis.
Note Note the position of the clock module before you remove it from the director chassis because
you must install the new clock module in the same position.
Step 3 Remove the four screws that secure the clock module to the backplane. (See Figure 2-44.)
1Clock A (CLK A) 2Clock B (CLK B)
Send documentation comments to mdsfeedback-doc@cisco.com.
2-82
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Clock Modules
Figure 2-44 Clock Module Replacement on the Cisco MDS 9509 Director (Rear View)
Step 4 Disconnect and gently remove the module, placing it on an antistatic mat or foam.
Step 5 Repeat Step 3 and Step 4 to remove any additional clock modules.
120166
Clock
module
Clock
module
Connectors
Connectors
Send documentation comments to mdsfeedback-doc@cisco.com.
2-83
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Clock Modules
Installing a Clock Module into the Cisco MDS 9509 Director
Caution Always wear an ESD wrist strap when handling modules or coming into contact with internal
components.
To install the clock module, follow these steps:
Step 1 Remove the new clock module from the antistatic bag.
Step 2 Hold the module with the connectors away from you.
Step 3 Carefully press the module onto the two matching connectors on the backplane.
Note You must install the new clock module in the same position that you removed it.
Step 4 Replace the four screws to secure the clock module onto the backplane.
Step 5 Repeat Step 1 through Step 4 to install any additional clock modules.
Step 6 Replace the back panel safety cover using the 18 screws.
Step 7 Provide power to the power supplies as described in the “Connecting the Power Supplies” section on
page 2-28.
Caution In a system with dual power supplies, connect each power supply to a separate power source.
In case of a power source failure, the second source will most likely still be available.
Step 8 Verify power supply operation by checking that the power supply LEDs are in the following states:
INPUT OK LED is green.
FAN OK LED is green.
OUTPUT FAIL LED is off.
Removing a Clock Module from the Cisco MDS 9506 Director
Before replacing the clock module, check the contents of your kit. Table 2-7 lists the contents of the
clock module replacement kit, part number DS-C9506-CL=.
Ta b l e 2-7 Contents of Cisco MDS 9506 Clock Module Replacement Kit
Quantity Part Description
1Cisco MDS 9506 clock module
12 M3 x 6-mm Phillips pan-head screws
1Disposable ESD wrist strap
Send documentation comments to mdsfeedback-doc@cisco.com.
2-84
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Clock Modules
These tools are required to remove and install a clock module:
Number 1 Phillips screwdriver
Your own ESD-prevention equipment or the disposable grounding wrist strap included with the
clock module replacement kit
The clock module is located behind the top power supply in the rear of the Cisco MDS 9506 Director.
Figure 2-45 shows the rear view of the Cisco MDS 9506 Director with both power supplies removed.
Figure 2-45 Clock Module Location on the Cisco MDS 9506 Director (Rear View)
Caution Always wear an ESD wrist strap when handling modules or coming into contact with internal
components.
1Clock module
Cisco MDS 9506
1
120093
Send documentation comments to mdsfeedback-doc@cisco.com.
2-85
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Clock Modules
To remove the clock module, follow these steps:
Step 1 Remove power from both PEMs, accessed from the front of the chassis as follows:
If the PEM is AC, press the power switch to off (0). Remove the power cord from the PEM.
If the PEM is DC, follow the instructions in the “Removing a DC PEM” section on page 2-64.
Step 2 Loosen the four captive screws on the top power supply.
Step 3 Grasp both power supply handles and slide the top power supply completely out of the chassis.
Step 4 Remove the three screws that secure the clock module to the backplane (See Figure 2-46).
Figure 2-46 Clock Module Replacement on the Cisco MDS 9506 Director (Rear View)
Step 5 The clock module has one connector to the backplane. Gently disconnect and remove the clock module,
placing it on an antistatic mat or foam.
Note Note the position of the clock module before you remove it from the director chassis because
you must install the new clock module in the same position.
120165
Clock
module
Connector
Send documentation comments to mdsfeedback-doc@cisco.com.
2-86
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Clock Modules
Installing a Clock Module into the Cisco MDS 9506 Director
Caution Always wear an ESD wrist strap when handling modules or coming into contact with internal
components.
To install the clock module, follow these steps:
Step 1 Remove the new clock module from the antistatic bag.
Step 2 Hold the module with the connector away from you and carefully press the module onto the backplane
connector.
Note You must install the new clock module in the same position that you removed it.
Step 3 Replace the three securing screws on the clock module.
Step 4 Grasp both power supply handles and slide the power supply into the power supply bay, ensuring that
the power supply is fully seated in the bay.
Step 5 Tighten the captive screws on the power supply to 8 in-lb.
Step 6 Provide power to the PEMs as described in the “Connecting the Power Supplies” section on page 2-28.
Caution In a system with dual power supplies, connect each power supply to a separate power source.
In case of a power source failure, the second source will most likely still be available.
Step 7 Verify power supply operation by checking that the power supply LEDs are in the following states:
INPUT OK LED is green.
FAN OK LED is green.
OUTPUT FAIL LED is off.
Send documentation comments to mdsfeedback-doc@cisco.com.
A-1
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
APPENDIX
A
Migrating to Generation 3 8-Gbps Fibre Channel
Switching Modules
This appendix describes the tasks associated with readying the MDS 9500 Series to support Generation
3 8-Gbps Fibre Channel switching modules. It presents an overview of the Generation 3 8-Gbps
modules, provides usage guidelines for the modules, and describes three procedures for migrating
hardware and upgrading software to enable use of these modules in an MDS 9513 Director.
This appendix includes the following sections:
Overview, page A-1
Usage Guidelines, page A-2
Before You Begin Upgrading the MDS 9513 Director, page A-3
Migration Procedures for the MDS 9513 Director, page A-3
Migration Procedure for the MDS 9509 Director and MDS 9506 Director, page A-12
Overview
Cisco MDS NX-OS 4.1(1b) supports the following Generation 3 8-Gbps modules:
MDS 9000 4/44-port 8-Gbps Host-Optimized Fibre Channel module (DS-X9248-48K9)
MDS 9000 24-port 8-Gbps Fibre Channel module (DS-X9224-96K9)
MDS 9000 48-port 8-Gbps Fibre Channel module (DS-X9248-96K9)
In addition, Cisco MDS NX-OS 4.1(1b) supports two fabric modules, which are also known as crossbar
modules, for the MDS 9513 Director:
MDS 9513 Fabric 2 module, DS-13SLT-FAB2
MDS 9513 Fabric 1 module, DS-13SLT-FAB1
The MDS 9513 Director requires Cisco MDS NX-OS 4.1(1b) and the MDS 9513 Fabric 2 modules to
support the MDS 9000 48-port 8-Gbps Fibre Channel module and the MDS 9000 24-port 8-Gbps Fibre
Channel module. Two MDS 9513 Fabric 2 modules can double the active backplane bandwidth of the
MDS 9513 Director to 192-Gbps full duplex per slot when used in conjunction with these two
Generation 3 modules.
The MDS 9513 Director requires Cisco MDS NX-OS 4.1(1b), but does not require the MDS 9513 Fabric
2 modules to support the MDS 9000 4/44-port 8-Gbps Host-optimized Fibre Channel module.
Send documentation comments to mdsfeedback-doc@cisco.com.
A-2
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Usage Guidelines
The MDS 9509 Director and the MDS 9506 Director also support the Generation 3 8-Gbps modules. The
switches require Supervisor-2 modules and Cisco MDS NX-OS 4.1(1b) to support the Generation 3
8-Gbps modules.
Note To upgrade to NX-OS Release 4.1(1b) from SAN-OS Release 3.2(3a) or earlier, first upgrade to SAN-OS
Release 3.3(1x) and then upgrade to NX-OS Release 4.1(1b).
Usage Guidelines
In preparation for using the MDS 9513 Fabric 2 module and the Generation 3 8-Gbps modules in an
MDS 9513 Director, be aware of the following usage guidelines:
Cisco SAN-OS release 3.x supports the MDS 9513 Fabric 2 module.
Until you upgrade to Cisco NX-OS 4.1(1b) and reload the switch, a MDS 9513 Fabric 2 module
functions like a MDS 9513 Fabric 1 module.
You cannot use any Generation 3 8-Gbps module in a MDS 9513 Director, MDS 9509 Director, or
MDS 9506 Director until you upgrade to NX-OS 4.1(1b).
Supervisor-2 modules are required for the MDS 9509 Director and the MDS 9506 Director to
support any Generation 3 8-Gbps module.
You must do the following to enable the increased bandwidth capabilities of the MDS 9513 Fabric
2 modules:
Upgrade from Cisco SAN-OS 3.x to NX-OS release 4.1(1b).
Migrate the existing MDS 9513 Fabric 1 modules in the MDS 9513 chassis to MDS 9513 Fabric
2 modules.
Reload the switch to enable the increased bandwidth.
If you install just one MDS 9513 Fabric 2 module, the active slot bandwidth of MDS 9513 Director
is 96-Gbps full duplex.
Once you upgrade to Cisco NX-OS 4.1(1b) and reload the switch, a downgrade to Cisco SAN-OS
release 3.x will be disruptive. Following the downgrade, the Generation 3 8-Gbps modules in the
switch will not power up.
Table A-1 lists the types of Generation 3 modules that the MDS 9513 Director supports.
Ta b l e A-1 Module Support Matrix for the MDS 9513 Director
Generation 3 Module Fabric Module Software Release
MDS 9000 4/44-port 8-Gbps Host-optimized module,
DS-X9248-48K9
MDS 9513 Fabric 1
module or MDS
9513 Fabric 2
module
Cisco NX-OS
4.1(1b)
MDS 9000 48-port 8-Gbps Fibre Channel module,
DS-X9248-96K9
MDS 9513 Fabric 2
module
Cisco NX-OS
4.1(1b)
MDS 9000 24-port 8-Gbps Fibre Channel module,
DS-X9224-96K9
MDS 9513 Fabric 2
module
Cisco NX-OS
4.1(1b)
Send documentation comments to mdsfeedback-doc@cisco.com.
A-3
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Before You Begin Upgrading the MDS 9513 Director
Before You Begin Upgrading the MDS 9513 Director
The sections that follow present three procedures for readying an MDS 9513 Director to support the
Generation 3 8-Gbps modules. Before you begin one of these procedures, do the following:
1. Review the steps involved in each procedure, and then choose the one that best fits your business
needs. In particular, decide which of the following you want to do:
Install the MDS 9000 4/44-port 8-Gbps Host-Optimized module and retain the MDS 9513
Fabric 1 module in the switch.
Install the MDS 9513 Fabric 2 modules and continue to run Cisco MDS SAN-OS 3.x software
in preparation for use of a Generation 3 module at a later time.
Install the MDS 9513 Fabric 2 modules for immediate use of any Generation 3 module.
Your choice will determine which procedure you should follow.
2. Observe the following differences in the MDS 9513 Fabric 1 and MDS 9513 Fabric 2 modules:
The MDS 9513 Fabric 1 module, DS-13SLT-FAB1, has a light blue surface above the top-most
captive screw on the front of the module.
The MDS 9513 Fabric 2 module, DS-13SLT-FAB2, has a light pink surface above the top-most
captive screw on the front of the module.
3. Examine the slots for the fabric modules at the rear of the MDS 9513 chassis. The left slot is marked
Fabric 1 and the right slot is marked Fabric 2. The slot name does not have any meaning in terms of
which fabric module can be installed in it. The MDS 9513 Fabric 2 module, DS-13SLT-FAB2, can
be installed in either slot, and the MDS 9513 Fabric 1 module DS-13SLT-FAB1, can be installed in
either slot.
Migration Procedures for the MDS 9513 Director
This section presents three procedures for migrating your hardware and upgrading your software in the
MDS 9513 to make it ready for the Generation 8-Gbps modules. Each procedure lists the tasks involved
and the benefits of the particular procedure.
Installing the MDS 9000 4/44-Port 8-Gbps Host-Optimized Module
This procedure allows you to start using an 8-Gbps module, without replacing the MDS 9513 Fabric 1
modules in the switch. The procedure consists of the following tasks:
Upgrade the MDS 9513 Director to Cisco NX-OS 4.1(1b).
Install the MDS 9000 4/44-port 8-Gbps Host-Optimized module.
This procedure offers the following benefits:
There is no service disruption. The upgrade to Cisco NX-OS 4.1(1b) is nondisruptive.
You immediately realize the benefit of the faster 8-Gbps port speed.
To nondisruptively upgrade to Cisco NX-OS 4.1(1b), and install the MDS 9000 4/44-port 8-Gbps
Host-Optimized module, follow these steps:
Step 1 Connect a PC to the console port on the active supervisor module and log in to the switch.
Send documentation comments to mdsfeedback-doc@cisco.com.
A-4
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Migration Procedures for the MDS 9513 Director
Step 2 Verify that the MDS 9513 Director is running Cisco SAN-OS 3.x by entering the show version command
at the command line.
This example shows the output of the show version command:
switch# show version
Cisco Storage Area Networking Operating System (SAN-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2006, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained herein are owned by
other third parties and are used and distributed under license.
Some parts of this software may be covered under the GNU Public
License or the GNU Lesser General Public License. A copy of
each such license is available at
http://www.gnu.org/licenses/gpl.html and
http://www.gnu.org/licenses/lgpl.html
Software
BIOS: version 1.1.0
loader: version 1.2(2)
kickstart: version 3.0(3) [gdb]
system: version 3.0(3) [gdb]
BIOS compile time: 10/24/03
kickstart image file is: bootflash:///boot-3.0.3
kickstart compile time: 9/15/2006 10:00:00 [10/02/2006 06:26:25]
system image file is: bootflash:///isan-3.0.3
system compile time: 9/15/2006 10:00:00 [10/02/2006 06:45:25]
Step 3 Upgrade to Cisco NX-OS 4.1(1b). Refer to the upgrade procedure described in the MDS 9000 Family
CLI Configuration Guide.
Step 4 Verify that the switch is running Cisco NX-OS 4.1(1b) by entering the show version command.
This example shows the output of the show version command:
switch# show version
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2008, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained herein are owned by
other third parties and are used and distributed under license.
Some parts of this software are covered under the GNU Public
License. A copy of the license is available at
http://www.gnu.org/licenses/gpl.html.
Software
BIOS: version 1.0.7
loader: version N/A
kickstart: version 4.1(1b)
system: version 4.1(1b)
BIOS compile time: 08/26/08
kickstart image file is: bootflash:/bootimage
kickstart compile time: 10/12/2020 25:00:00 [09/06/2008 01:36:07]
system image file is: bootflash:/isanimage
system compile time: 8/22/2008 0:00:00 [09/06/2008 02:48:50]
Hardware
cisco MDS 9513 (13 Slot) Chassis ("Supervisor/Fabric-2")
Motorola, 7447A, altivec with 1032472 kB of memory.
Processor Board ID JAE1217FOFI
Device name: sw5-qa01
bootflash: 1023120 kB
slot0: 511664 kB (expansion flash)
Kernel uptime is 1 day(s), 9 hour(s), 12 minute(s), 4 second(s)
Last reset at 518531 usecs after Sun Sep 7 01:29:37 2008
Reason: Reset triggered due to Switchover Request by User
Send documentation comments to mdsfeedback-doc@cisco.com.
A-5
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Migration Procedures for the MDS 9513 Director
System version: 4.1(1b)
Service:
Step 5 Install the MDS 9000 4/44-port 8-Gbps Host-Optimized Fibre Channel module.
Step 6 Refer to the Cisco MDS 9000 Family CLI Configuration Guide or Cisco MDS 9000 Family Fabric
Manager Configuration Guide for information on how to configure the module.
Installing MDS 9513 Fabric 2 Modules and Running Cisco SAN-OS 3.x
This procedure allows you to prepare your switch for the future installation of an MDS 48-port 8-Gbps
module or an MDS 9000 24-port 8-Gbps module. The procedure consists of the following tasks:
Replace the MDS 9513 Fabric 1 modules with MDS 9513 Fabric 2 modules.
This procedure offers the following benefits:
There is no service disruption. The installation of the MDS 9513 Fabric 2 modules is nondisruptive,
and you can continue running Cisco SAN-OS 3.x.
You have completed the MDS 9513 hardware upgrade.
You can schedule time for proceeding with the software upgrade and the installation of Generation
3 modules at a later time.
To nondisruptively remove a MDS 9513 Fabric 1 module from the Cisco MDS 9513 Director and replace
it with a MDS 9513 Fabric 2 module, follow these steps:
Step 1 Connect a PC to the console port on the active supervisor module and log in to the switch.
Step 2 Enter the show module command to determine which supervisor and its associated fabric module are in
active mode.
The supervisor module in slot 7 is associated with the fabric module in the Fabric 1 slot and the
supervisor module in slot 8 is associated with the fabric module in the Fabric 2 slot.
The following example shows the output of the show module command, which indicates that the
supervisor in slot 7 is active and the supervisor in slot 8 is in standby mode.
switch# show module
Mod Ports Module-Type Model Status
--- ----- -------------------------------- ------------------ ------------
7 0 Supervisor/Fabric-2 DS-X9530-SF2-K9 ha-standby
8 0 Supervisor/Fabric-2 DS-X9530-SF2-K9 active *
Step 3 If the supervisor module in slot 7 is active, shut down the standby supervisor and fabric module by
entering the out-of-service xbar 2 command.
The following example shows how to shut down the standby supervisor and associated fabric module in
slot 2.
switch# out-of-service xbar 2
Step 4 If the supervisor module in slot 8 is active, shut down the standby supervisor and fabric module by
entering the out-of-service xbar 1 command.
The following example shows the output of the show module command and then shows how to shut
down the standby supervisor (in slot 7) and its associated fabric module in the Fabric 1 slot.
Send documentation comments to mdsfeedback-doc@cisco.com.
A-6
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Migration Procedures for the MDS 9513 Director
switch# show module
Mod Ports Module-Type Model Status
--- ----- -------------------------------- ------------------ ------------
7 0 Supervisor/Fabric-2 DS-X9530-SF2-K9 ha-standby
8 0 Supervisor/Fabric-2 DS-X9530-SF2-K9 active *
switch# out-of-service xbar 1
Step 5 Enter the show module xbar command to verify that the standby supervisor module is powered down.
Step 6 Attach a ESD wrist strap according to the instructions in the section “Preventing Electrostatic Discharge
Damage” section on page 2-19.
Step 7 Confirm that the LED light is red, which indicates that the module is powered off, and then loosen the
two captive screws on the module being removed.
Step 8 Remove the module from the chassis as follows:
a. Place your thumbs on the top and bottom ejector levers and simultaneously rotate the levers outward
to unseat the module from the midplane connector. (See Figure A-1)
b. Hold the front edge of the module and slide the module partially out of the slot. Do not touch the
module circuitry.
Send documentation comments to mdsfeedback-doc@cisco.com.
A-7
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Migration Procedures for the MDS 9513 Director
Figure A-1 Captive Screws and Ejector Levers on the Fabric Module
Step 9 Place the MDS 9513 Fabric 1 module on an antistatic surface.
Step 10 On the MDS 9513 Fabric 2 module to be installed, ensure that the ejector levers are completely open.
Step 11 Position the MDS 9513 Fabric 2 module in the chassis as follows:
a. Position the module in the empty slot. Ensure that you align the sides of the module carrier with the
slot guides on each side of the slot.
b. Slide the module carefully into the slot until the EMI gasket along the top edge of the module
contacts the module in the slot above it and both ejector levers close to approximately 45 degrees
with respect to the front of the module. (See Figure A-2.)
1Captive screws 2Ejector levers
3Fabric slot 1 label 4Fabric slot 2 label
5Power LEDs
188730
1
1
2
2
5
4
3
Send documentation comments to mdsfeedback-doc@cisco.com.
A-8
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Migration Procedures for the MDS 9513 Director
Figure A-2 Installing a Fabric Module
c. Grasp the two ejector levers using the thumb and forefinger of each hand, and press down to create
a small 0.040-inch (1-mm) gap between the module's EMI gasket and the module above it.
Caution Do not press down too forcefully on the levers because they can bend.
d. While pressing down, simultaneously close the top and bottom ejector levers to completely seat the
module in the midplane connector. The ejector levers are completely closed when they are flush with
the front of the module.
Note Ensure that the ejector levers are completely closed before tightening the captive screws. Failure
to completely seat the module in the backplane connector can result in error messages.
e. Tighten the two captive screws on the module until they are finger tight.
Step 12 Verify that the LED light on the front of the module is green. The light should come on within five
seconds of the module being inserted. If it does not, check to see if the module is seated correctly in the
slot.
Step 13 Enter the system switchover command to put the other supervisor in active mode.
147940
Send documentation comments to mdsfeedback-doc@cisco.com.
A-9
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Migration Procedures for the MDS 9513 Director
Step 14 Move the console cable to the console port on the active supervisor.
Step 15 Enter the show module command to confirm which supervisor module is active.
Step 16 Enter the out-of-service xbar slot command (where slot refers to the external fabric module slot
number) to shut down the standby supervisor
Step 17 Remove the out-of-service fabric module and install a MDS 9513 Fabric 2 module by repeating steps 7
through 12.
Step 18 After you have replaced both MDS 9513 Fabric 1 modules, enter the show module xbar command to
verify that the system can detect the MDS 9513 Fabric 2 modules and that their status is ok.
This example shows the output of the show module xbar command:
switch# show module xbar
Xbar Ports Module-Type Model Status
--- ----- -------------------------------- ------------------ ------------
1 0 Fabric Module 2 DS-13SLT-FAB2 ok
2 0 Fabric Module 2 DS-13SLT-FAB2 ok
Xbar Sw Hw World-Wide-Name(s) (WWN)
--- -------------- ------ --------------------------------------------------
1 NA 2.0 --
2 NA 2.0 --
Xbar MAC-Address(es) Serial-Num
--- -------------------------------------- ----------
1 NA JAF1207ARRS
2 NA JAE1212BPR0
* this terminal session
switch#
The MDS 9513 Director with the MDS 9513 Fabric 2 modules should function as it did prior to the
migration procedure. Until you upgrade to Cisco NX-OS 4.1(1b) and reload the switch, the MDS 9513
Fabric 2 modules function like MDS 9513 Fabric 1 modules.
Installing MDS 9513 Fabric 2 Modules and Installing MDS 9000 24-port or
48-port 8-Gbps Modules
This procedure allows you to install the MDS 9513 Fabric 2 modules and activate the increased
backplane bandwidth of the MDS 9513 Director. The procedure consists of the following tasks:
Upgrade to NX-OS 4.1(1b). This is a nondisruptive procedure.
Replace the MDS 9513 Fabric 1 modules with MDS 9513 Fabric 2 modules.
Install the MDS 9000 48-port or 24-port 8-Gbps Fibre Channel modules.
Activate the higher bandwidth capabilities of the MDS 9513 Fabric 2 modules.
This procedure offers the following benefits:
You double the active backplane bandwidth to 192-Gbps full duplex per slot on the MDS 9513
Director once you activate the increased bandwidth capabilities of the MDS 9513 Fabric 2 modules
through a reload or power cycle.
You simplify the migration process if you choose to power down the switch and install all the
hardware modules at one time.
Send documentation comments to mdsfeedback-doc@cisco.com.
A-10
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Migration Procedures for the MDS 9513 Director
Activating the higher bandwidth capabilities of the MDS 9513 Fabric 2 modules can occur in one of two
ways:
You can enter the reload command after a nondisruptive installation of the MDS 9513 Fabric 2
modules.
You can power down the switch, install the MDS 9513 Fabric 2 modules, and then power up the
switch.
Both methods are disruptive. The latter method is a best practice because it requires fewer steps.
Depending on which method you choose, follow the instructions in either the “Installing the MDS 9513
Fabric 2 Modules and Activating Higher Bandwidth by Reloading the Switch” section on page A-10 or
in the “Installing the MDS 9513 Fabric 2 Modules and Activating Higher Bandwidth by Powering Down
the Switch” section on page A-11.
Installing the MDS 9513 Fabric 2 Modules and Activating Higher Bandwidth by Reloading the Switch
Figure A-3 shows the process flow that occurs when you reload the switch to activate the higher
bandwidth capabilities of the MDS 9513 Fabric 2 modules.
Figure A-3 Strategy 2: Migration Process Flow
To reload the switch to activate the increased bandwidth capabilities of the MDS 9513 Fabric 2 modules,
follow these steps:
Step 1 Upgrade to Cisco NX-OS 4.1(1b). Refer to the upgrade procedure described in the MDS 9000 Family
CLI Configuration Guide.
Step 2 Verify that the switch is running Cisco NX-OS 4.1(1b) by entering the show version command.
Step 3 Enter the copy running-config startup-config command to save a copy of the current switch
configuration.
Step 4 Check the type of fabric modules that are present in the chassis by entering the show module xbar
command.
Step 5 If there are MDS 9513 Fabric 1 modules in the chassis, replace them according to the instructions in
the“Installing MDS 9513 Fabric 2 Modules and Running Cisco SAN-OS 3.x” section on page A-5.
Step 6 Enter the show hardware fabric-mode command to display information about Generation 3 module
support.
The following example shows the output of the show hardware fabric-mode command, which indicates
that support for the MDS 9000 48-port and 24-port 8-Gbps Generation 3 modules has not been enabled
for the switch.
Send documentation comments to mdsfeedback-doc@cisco.com.
A-11
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Migration Procedures for the MDS 9513 Director
switch# show hardware fabric-mode
Fabric mode supports only one configuration of Gen3 Linecards - 4/44 Host-Optimized 8G FC
Linecard.
switch#
Failure message for Gen3 cards for fabric2 in the above fabric-mode:switch# 2008 Jul 24
10:27:58 switch %XBAR-2-INCOMPATIBLE_CONFIG: Fabric mode does not support linecard in slot
4 . Please reload the switch to support 24-port and 48-port 8G FC linecards.
Step 7 Enter the reload command to enable the increased bandwidth capabilities of the MDS 9513 Fabric 2
modules.
Step 8 When the switch comes back up, install the MDS 9000 48-port or 24-port 8-Gbps Fibre Channel
modules.
Step 9 Enter the show hardware fabric-mode command to verify that increased bandwidth capabilities are
activated.
The following example shows the output of the show hardware fabric-mode command, and indicates
that support for the MDS 9000 48-port and 24-port 8-Gbps Generation 3 modules has been activated.
switch# show hardware fabric-mode
Fabric mode supports Gen3 and above linecards.
switch#
Step 10 Refer to the Cisco MDS 9000 Family CLI Configuration Guide or Cisco MDS 9000 Family Fabric
Manager Configuration Guide for information on how to configure the MDS 9000 48-port or 24-port
8-Gbps Fibre Channel modules.
Installing the MDS 9513 Fabric 2 Modules and Activating Higher Bandwidth by Powering Down the
Switch
To power down the switch to activate the increased bandwidth capabilities of the MDS 9513 Fabric 2
modules, follow these steps:
Step 1 Upgrade to Cisco NX-OS 4.1(1b). Refer to the upgrade procedure described in the MDS 9000 Family
CLI Configuration Guide.
Step 2 Verify that the switch is running Cisco NX-OS 4.1(1b) by entering the show version command.
Step 3 Enter the copy running-config startup-config command to save a copy of the current switch
configuration.
Step 4 Power down the switch by turning the power supply switch at the rear of the power supply
counterclockwise to the off position on both power supplies.
Step 5 Remove the MDS 9513 Fabric 1 modules and replace them with MDS 9513 Fabric 2 modules. See steps
5 through 10 in the “Installing MDS 9513 Fabric 2 Modules and Running Cisco SAN-OS 3.x” section
on page A-5.
Step 6 Install the MDS 9000 48-port or 24-port 8-Gbps Fibre Channel modules.
Step 7 Power up the switch by turning the power supply switch at the rear of the power supply clockwise to the
on position on both power supplies.
Step 8 Enter the show hardware fabric-mode command to verify that increased bandwidth capabilities are
activated.
The following example shows the output of the show hardware fabric-mode command, and indicates
that support for the MDS 9000 48-port and 24-port 8-Gbps Generation 3 modules has been activated.
Send documentation comments to mdsfeedback-doc@cisco.com.
A-12
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Migration Procedure for the MDS 9509 Director and MDS 9506 Director
switch# show hardware fabric-mode
Fabric mode supports Gen3 and above linecards.
switch#
Step 9 Refer to the Cisco MDS 9000 Family CLI Configuration Guide or Cisco MDS 9000 Family Fabric
Manager Configuration Guide for information on how to configure the MDS 9000 48-port or 24-port
8-Gbps Fibre Channel modules.
Migration Procedure for the MDS 9509 Director and MDS 9506
Director
Note Do not upgrade to NX-OS 4.1(1b) if a Supervisor-1 module is installed.
To use any Generation 3 8-Gbps module in an MDS 9509 Director or MDS 9506 Director, follow these
steps:
Step 1 Log in to the switch.
Step 2 Verify that the switch is running Cisco NX-OS 4.1(1b) by entering the show version command.
If the switch has NX-OS 4.x or higher installed, then Supervisor-2 module is already installed on the
switch. Skip to step 7 to install any Generation 3 8-Gbps module.
Step 3 Enter the show module command to determine which supervisor module is in active mode and which is
in standby module. Supervisor modules are installed in slot 5 and slot 6 on the MDS 9509 Director and
MDS 9506 Director.
The following example shows the output of the show module command:
switch# show module
Mod Ports Module-Type Model Status
--- ----- -------------------------------- ------------------ ------------
4 22 4x1GE IPS, 18x1/2/4Gbps FC Modul DS-X9304-18K9 ok
5 0 Supervisor/Fabric-1 DS-X9530-SF1-K9 active *
6 0 Supervisor/Fabric-1 DS-X9530-SF1-K9 ha-standby
Mod Sw Hw World-Wide-Name(s) (WWN)
--- -------------- ------ --------------------------------------------------
4 4.1(0.182) 0.304 20:c1:00:05:30:00:a7:9e to 20:d2:00:05:30:00:a7:9e
5 4.1(0.182) 4.0 --
6 4.1(0.182) 0.0 --
Mod MAC-Address(es) Serial-Num
--- -------------------------------------- ----------
4 00-19-56-be-65-d0 to 00-19-56-be-65-d8 JAB1107027K
5 00-0c-30-0d-2b-b8 to 00-0c-30-0d-2b-bc JAB074004VE
6 00-05-30-00-52-f2 to 00-05-30-00-52-f6 NA
Step 4 If the switch has Supervisor-1 modules installed, remove the modules according to the instructions in
the “Removing Supervisor Modules” section on page 2-39. If the switch has Supervisor-2 modules
installed, then skip to Step 6.
Send documentation comments to mdsfeedback-doc@cisco.com.
A-13
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Migration Procedure for the MDS 9509 Director and MDS 9506 Director
Step 5 Install Supervisor-2 modules according to the instructions in the “Installing Supervisor Modules”
section on page 2-40. Refer to the Migrating from Supervisor-1 Modules to Supervisor-2 Modules
procedure described in the MDS 9000 Family CLI Configuration Guide.
Step 6 Upgrade to Cisco NX-OS 4.1(1b). Refer to the upgrade procedure described in the MDS 9000 Family
CLI Configuration Guide.
Step 7 Install any Generation 3 8-Gbps module.
Step 8 Refer to the Cisco MDS 9000 Family CLI Configuration Guide or Cisco MDS 9000 Family Fabric
Manager Configuration Guide for information on how to configure a Generation 3 8-Gbps module.
Send documentation comments to mdsfeedback-doc@cisco.com.
A-14
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Migration Procedure for the MDS 9509 Director and MDS 9506 Director
CHAPTER
Send documentation comments to mdsfeedback-doc@cisco.com.
B-1
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
B
Connecting the Cisco MDS 9500 Series
The Cisco MDS 9500 Series provides the following types of ports:
Console port (supervisor modules) —An RS-232 port that you can use to create a local management
connection.
COM1 port (supervisor modules)—An RS-232 port that you can use to connect to an external serial
communication device such as a modem.
MGMT 10/100/1000 Ethernet port (Supervisor-2 module)—An Ethernet port that you can use to
access and manage the switch by IP address, such as through Fabric Manager.
MGMT 10/100 Ethernet port (Supervisor-1 module)—An Ethernet port that you can use to access
and manage the switch by IP address, such as through Fabric Manager.
Fibre Channel ports (switching modules)—Fibre Channel ports that you can use to connect to the
SAN or for in-band management.
Gigabit Ethernet ports (IP services modules)—Gigabit Ethernet ports that you can use for iSCSI
and/or FCIP.
Two USB ports (Supervisor-2 module)—A simple interface that allows you to connect to different
devices supported by Cisco MDS SAN-OS and NX-OS. On the double-decker connector, USB port
1 is on the upper position and port 2 is on the lower position.
Note The USB ports are not functional on Cisco MDS SAN-OS Release 3.0(1) or earlier.
CPU subsystem based on Motorola PowerPC 7447
This chapter includes the following sections:
Preparing for Network Connections, page B-2
Connecting to the Console Port, page B-2
Connecting to the COM1 Port, page B-4
Connecting to the MGMT 10/100/1000 Ethernet Port, page B-6
Connecting to the MGMT 10/100 Ethernet Port, page B-7
Connecting to a Fibre Channel Port, page B-9
Send documentation comments to mdsfeedback-doc@cisco.com.
B-2
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Preparing for Network Connections
Caution When running power and data cables in overhead or subfloor cable trays, we strongly recommend that
power cables and other potential noise sources be located as far away as is practical from network
cabling that terminates on Cisco equipment. In situations where long parallel cable runs cannot be
separated by at least 3.3 ft (1 m), we recommend shielding any potential noise sources by housing them
in a grounded metallic conduit.
Note The Cisco MDS 9506 Director and Cisco MDS 9509 Director use the Supervisor-1 module and require
the same port connecting procedures.
Preparing for Network Connections
When preparing your site for network connections to the Cisco MDS 9500 Series, consider the following
for each type of interface, and gather all the required equipment before connecting the ports:
Cabling required for each interface type
Distance limitations for each signal type
Additional interface equipment required
Connecting to the Console Port
The console port, labeled “Console,” is an RS-232 port with an RJ-45 interface (see Figure B-1). It is an
asynchronous (async) serial port; any device connected to this port must be capable of asynchronous
transmission.
We recommend using this port to create a local management connection to set the IP address and other
initial configuration settings before connecting the switch to the network for the first time.
Send documentation comments to mdsfeedback-doc@cisco.com.
B-3
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to the Console Port
Figure B-1 Connecting to the Console Port on the Supervisor Module for the Cisco MDS 9500
Series
Note Connecting the console port to a modem is supported for switches running Cisco MDS SAN-OS Release
1.2(2a) or later or NX-OS Release 4.1(1b).
Caution The console port can be used to connect to a modem, however, we recommend using the COM1 port for
this purpose. If you decide to connect the console port to a modem, do not connect it while the switch is
booting; connect either before powering the switch on or after the switch has completed the boot process.
You can use the console port to perform the following functions:
Configure the Cisco MDS 9500 from the CLI.
Monitor network statistics and errors.
Configure SNMP agent parameters.
Download software updates.
Note To connect the console port to a computer terminal, the computer must support VT100 terminal
emulation. The terminal emulation software—frequently an application such as HyperTerminal or
Procomm Plus—makes communication between the switch and computer possible during setup and
configuration.
91701
Console
Send documentation comments to mdsfeedback-doc@cisco.com.
B-4
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to the COM1 Port
To connect the console port to a computer terminal, follow these steps:
Step 1 Configure the terminal emulator program to match the following default port characteristics: 9600 baud,
8 data bits, 1 stop bit, no parity.
Step 2 Connect the supplied RJ-45 to DB-9 female adapter or RJ-45 to DP-25 female adapter (depending on
your computer) to the computer serial port. We recommend using the adapter and cable provided with
the switch.
Step 3 Connect the console cable (a rollover RJ-45 to RJ-45 cable) to the console port and to the RJ-45 to DB-9
adapter or the RJ-45 to DP-25 adapter (depending on your computer) at the computer serial port.
Note For configuration instructions, see the Cisco MDS 9000 Family CLI Configuration Guide or the
Cisco MDS 9000 Family Fabric Manager Configuration Guide.
Connecting to the COM1 Port
Note The COM1 port is not supported for connection to a console.
The COM1 port (labeled “COM1”) is an RS-232 port with a DB-9 interface (see Figure B-2). You can
use it to connect to an external serial communication device such as a modem. For information about
how to turn off hardware flow control, see the Cisco MDS 9000 Family CLI Configuration Guide.
Note Switches running Cisco MDS SAN-OS Release 1.2(1a) or later NX-OS Release 4.1(1b) support the
connection of a COM1 port to a modem.
Send documentation comments to mdsfeedback-doc@cisco.com.
B-5
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to the COM1 Port
Figure B-2 Connecting to the COM1 Port on the Supervisor Module for the Cisco MDS 9500
Series
To connect the COM1 port to a modem, follow these steps:
Step 1 Connect the modem to the COM1 port using the adapters and cables provided with the accessory kit, as
follows:
a. Connect the DB-9 serial adapter to the COM1 port.
b. Connect the RJ-45 to DB-25 modem adapter to the modem.
c. Connect the adapters using the RJ-45 to RJ-45 rollover cable (or equivalent crossover cable).
99272
COM1
COM1
COM1
Send documentation comments to mdsfeedback-doc@cisco.com.
B-6
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to the MGMT 10/100/1000 Ethernet Port
Step 2 If the default settings for the COM1 are modified, see the Cisco MDS 9000 Family CLI Configuration
Guide containing information regarding verifying and resetting the default settings.
The default COM1 settings are as follows:
line Aux:
Speed: 9600 bauds
Databits: 8 bits per byte
Stopbits: 1 bit(s)
Parity: none
Modem In: Enable
Modem Init-String -
default: ATE0Q1&D2&C1S0=1\015
Statistics: tx:17 rx:0 Register Bits:RTS|DTR
Connecting to the MGMT 10/100/1000 Ethernet Port
Caution To prevent an IP address conflict, do not connect the MGMT 10/100/1000 Ethernet port to the network
until the initial configuration is complete. For more information, see the Cisco MDS 9000 Family CLI
Configuration Guide.
The Supervisor-2 module supports an autosensing MGMT 10/100/1000 Ethernet port (labeled “MGMT
10/100/1000”) and has an RJ-45 interface. (See Figure B-3.) You can use this port to access and manage
the switch by IP address, such as through Cisco Fabric Manager.
Figure B-3 Connecting to the MGMT 10/100/1000 Ethernet Port on the Supervisor-2 Module for
the Cisco MDS 9500 Series
144511
MGMT
10/100/1000
10/100/1000
WS-X9530-SF2-K9
10/100/1000LINK
ACT
LINK
2
2
CON1
CON1
ACT
Send documentation comments to mdsfeedback-doc@cisco.com.
B-7
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to the MGMT 10/100 Ethernet Port
To connect the MGMT 10/100/1000 Ethernet port to an external hub, switch, or router, follow these
steps:
Step 1 Connect the appropriate modular cable to the MGMT 10/100/1000 Ethernet port:
Use a modular, RJ-45, straight-through UTP cable to connect the MGMT 10/100/1000 Ethernet port
to an Ethernet switch port or hub.
Use a cross-over cable to connect to a router interface.
Step 2 Connect the other end of the cable to the device.
Note For high availability, connect the MGMT 10/100/1000 Ethernet port on the active Supervisor-2 module
and on the standby Supervisor-2 module to the same network or VLAN. The active supervisor module
owns the IP address used by both of these Ethernet connections. On a switchover, the newly activated
supervisor module takes over this IP address. This process requires an Ethernet connection to the newly
activated supervisor module.
Connecting to the MGMT 10/100 Ethernet Port
Caution To prevent an IP address conflict, do not connect the MGMT 10/100 Ethernet port to the network until
the initial configuration is complete. For more information, see the Cisco MDS 9000 Family CLI
Configuration Guide.
The Supervisor-1 module supports an autosensing MGMT 10/100 Ethernet port (labeled “MGMT
10/100”) and has an RJ-45 interface. (See Figure B-4.) You can use this port to access and manage the
switch by IP address, such as through Cisco Fabric Manager.
Send documentation comments to mdsfeedback-doc@cisco.com.
B-8
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to the MGMT 10/100 Ethernet Port
Figure B-4 Connecting to the MGMT 10/100 Ethernet Port on the Supervisor-1 Module for the
Cisco MDS 9500 Series
To connect the MGMT 10/100 Ethernet port to an external hub, switch, or router, follow these steps:
Step 1 Connect the appropriate modular cable to the MGMT 10/100 Ethernet port:
Use a modular, RJ-45, straight-through UTP cable to connect the MGMT 10/100 Ethernet port to an
Ethernet switch port or hub.
Use a cross-over cable to connect to a router interface.
Step 2 Connect the other end of the cable to the device.
Note For high availability, connect the MGMT 10/100 Ethernet port on the active Supervisor-1 module and
on the standby Supervisor-1 module to the same network or VLAN. The active supervisor module owns
the IP address used by both of these Ethernet connections. On a switchover, the newly activated
supervisor module takes over this IP address. This process requires an Ethernet connection to the newly
activated supervisor module.
99328
MGMT 10/100
Send documentation comments to mdsfeedback-doc@cisco.com.
B-9
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to a Fibre Channel Port
Connecting to a Fibre Channel Port
The Fibre Channel ports on the switching modules are compatible with LC-type fiber-optic SFP
transceivers and cables. You can use these ports to connect to the SAN or for in-band management. For
information about configuring the switch for in-band management, see the Cisco MDS 9000 Family CLI
Configuration Guide.
The Cisco MDS 9000 Family supports both Fibre Channel and Gigabit Ethernet protocols for SFP
transceivers. Each transceiver must match the transceiver on the other end of the cable, and the cable
must not exceed the stipulated cable length for reliable communication. For information on how to get
the list of supported SFP transceivers for your software release, see the Cisco MDS 9000 Family Release
Notes for Cisco MDS SAN-OS.
Warning
Class 1 laser product.
Statement 1008
Warning
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into
beams or view directly with optical instruments.
Statement 1051
Caution Wear an ESD wrist strap connected to the chassis when handling transceivers. Keep optical connectors
covered when not in use, and do not touch connector ends. The fiber-optic connectors must be free of
dust, oil, and other contaminants.
This section provides the following topics:
Removing and Installing X2 Transceivers, page B-9
Removing and Installing SFP Transceivers, page B-12
Removing and Installing Cables into SFP Transceivers, page B-14
Maintaining SFP Transceivers and Fiber-Optic Cables, page B-16
Removing and Installing X2 Transceivers
Caution Excessively removing and installing X2 transceivers can shorten its useful life. Do not remove and insert
X2 transceivers more often than is absolutely necessary. We recommend disconnecting cables before
installing or removing SFP transceivers to prevent damage to the cable or transceiver.
Note Use only Cisco X2 transceivers listed in Table D-19 on page D-20 on the Cisco MDS 9200 Series. Each
X2 transceiver is encoded with model information that enables the switch to verify that the X2
transceiver meets the requirements for the switch. For instructions specific to the transceiver type, see
the “X2 Transceiver Specifications” section on page D-19.
Send documentation comments to mdsfeedback-doc@cisco.com.
B-10
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to a Fibre Channel Port
The Cisco MDS 9000 Family supports X2 transceivers with SC connectors. (See Figure B-5.)
Figure B-5 Cisco MDS 9000 Family X2 Transceivers
1Transmit optical bore 6Module connector
2Receive optical bore 7Latch (extended)
3Latching sleeve (retracted) 8Latching sleeve (extended)
4EMI gasket 9Latch (retracted)
5Transceiver heat sink
5
6
120754
4
3
8
1
2
7
9
Latching sleeve retracted;
latch extended
Latching sleeve extended;
latch retracted
Send documentation comments to mdsfeedback-doc@cisco.com.
B-11
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to a Fibre Channel Port
Removing an X2 Transceiver
To remove an X2 transceiver, follow these steps:
Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use.
Step 2 If a cable is installed in the transceiver:
a. Record the cable and port connections for later reference.
b. Press the release latch on the cable, grasp the connector near the connection point, and gently pull
the connector from the transceiver.
c. Insert a dust plug into the cable end of the transceiver.
Caution If the transceiver does not remove easily in the next step, push the transceiver all the way back
in and then ensure that the latch is in the correct position before continuing.
Step 3 Remove the transceiver from the port.
Step 4 Insert a dust cover into the port end of the transceiver and place the transceiver on an antistatic mat or
into a static-shielding bag if you plan to return it to the factory.
Installing an X2 Transceiver
To install an X2 transceiver, follow these steps:
Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use.
Caution If the transceiver does not install easily, ensure that it is correctly oriented before continuing.
Step 2 Remove the dust cover from the port end of the transceiver.
Step 3 Insert the transceiver into the port. Ensure that the transceiver is fully seated.
Note If you cannot install the cable into the transceiver, insert or leave the dust plug in the cable end
of the transceiver.
Send documentation comments to mdsfeedback-doc@cisco.com.
B-12
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to a Fibre Channel Port
Removing and Installing SFP Transceivers
Caution Removing and installing an SFP transceiver can shorten its useful life. Do not remove and insert SFP
transceivers more often than is absolutely necessary. We recommend disconnecting cables before
installing or removing SFP transceivers to prevent damage to the cable or transceiver.
Note Use only Cisco SFP transceivers on the Cisco MDS 9200 Series. Each Cisco SFP transceiver is encoded
with model information that enables the switch to verify that the SFP transceiver meets the requirements
for the switch. For instructions specific to the transceiver type, see the “SFP and SFP+ Transceiver
Specifications” section on page D-22.
The Cisco MDS 9000 Family supports SFP transceivers with the following two types of latching devices:
Mylar tab latch (Figure B-6)
Bale-clasp latch (Figure B-7)
Figure B-6 SFP Transceiver with Mylar Tab Latch
Figure B-7 SFP Transceiver with Bale-Clasp Latch
Removing an SFP Transceiver
To remove an SFP transceiver, follow these steps:
Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use.
Step 2 If a cable is installed in the transceiver:
a. Record the cable and port connections for later reference.
b. Press the release latch on the cable, grasp the connector near the connection point, and gently pull
the connector from the transceiver.
63065
63067
Send documentation comments to mdsfeedback-doc@cisco.com.
B-13
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to a Fibre Channel Port
c. Insert a dust plug into the cable end of the transceiver.
Caution If the transceiver does not remove easily in the next step, push the transceiver all the way back
in and then ensure that the latch is in the correct position before continuing.
Step 3 Remove the transceiver from the port:
If the transceiver has a Mylar tab latch, gently pull the tab straight out (do not twist), and then pull
the transceiver out of the port.
If the transceiver has a bale clasp latch, open the clasp by pressing it downwards, and then pull the
transceiver out of the port.
Note If you have difficulty removing a bale clasp SFP transceiver, you should reseat the SFP by
returning the bale clasp in the up position. Then press the SFP inward and upward into the cage.
Next, lower the bale clasp and pull the SFP straight out with a slight upward lifting force (see
Figure B-8). Be careful not to damage the port cage during this process.
Figure B-8 Alternate Removal Method for Bale Clasp SFP Transceivers
Step 4 Insert a dust cover into the port end of the transceiver and place the transceiver on an antistatic mat or
into a static shielding bag if you plan to return it to the factory.
Step 5 If another transceiver is not being installed, protect the optical cage by inserting a clean cover.
115237
Send documentation comments to mdsfeedback-doc@cisco.com.
B-14
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to a Fibre Channel Port
Installing an SFP Transceiver
To install an SFP transceiver, follow these steps:
Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use.
Step 2 Remove the dust cover from the port cage.
Step 3 Remove the dust cover from the port end of the transceiver.
Step 4 Insert the transceiver into the port:
If the transceiver has a Mylar tab, orient the transceiver with the tab on the bottom, and then gently
insert the transceiver into the port until it clicks into place.
If the transceiver has a bale clasp, orient the transceiver with the clasp on the bottom, close the clasp
by pushing it up over the transceiver, and then gently insert the transceiver into the port until it clicks
into place.
Caution If the transceiver does not install easily, ensure that it is correctly oriented and the tab or clasp
are in the correct position before continuing.
Note If you cannot install the cable into the transceiver, insert or leave the dust plug in the cable end
of the transceiver.
Removing and Installing Cables into SFP Transceivers
Caution To prevent damage to the fiber-optic cables, do not place more tension on them than the rated limit and
do not bend to a radius of less than 1 inch if there is no tension in the cable, or 2 inches if there is tension
in the cable.
Removing a Cable from an SFP Transceiver
Caution When pulling a cable from a transceiver, grip the body of the connector. Do not pull on the jacket sleeve,
because this can compromise the fiber-optic termination in the connector.
Caution If the cable does not remove easily, ensure that any latch present on the cable has been released before
continuing.
To remove the cable, follow these steps:
Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use.
Send documentation comments to mdsfeedback-doc@cisco.com.
B-15
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to a Fibre Channel Port
Step 2 Press the release latch on the cable, grasp the connector near the connection point, and gently pull the
connector from the transceiver.
Step 3 Insert a dust plug into the cable end of the transceiver.
Step 4 Insert a dust plug onto the end of the cable.
Installing a Cable into an SFP Transceiver
Caution To prevent possible damage to the cable or transceiver, install the transceiver in the port before installing
the cable in the transceiver.
To install a cable into a transceiver, follow these steps:
Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use.
Step 2 Remove the dust cover from the connector on the cable.
Step 3 Remove the dust cover from the cable end of the transceiver.
Step 4 Align the cable connector with the transceiver and insert the connector into the transceiver until it clicks
into place (see Figure B-9).
Figure B-9 Connecting the LC-Type Cable to a Fibre Channel Port
Caution If the cable does not install easily, ensure that it is correctly oriented before continuing.
For instructions on verifying connectivity, see the Cisco MDS 9000 Family CLI Configuration Guide or
the Cisco MDS 9000 Family Fabric Manager Configuration Guide.
LC plug
SFP module
91681
Send documentation comments to mdsfeedback-doc@cisco.com.
B-16
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter B Connecting the Cisco MDS 9500 Series
Connecting to a Fibre Channel Port
Maintaining SFP Transceivers and Fiber-Optic Cables
SFP transceivers and fiber-optic cables must be kept clean and dust-free to maintain high signal accuracy
and prevent damage to the connectors. Attenuation (Loss Of Light) is increased by contamination and
should be below 0.35 dB.
Consider the following maintenance guidelines:
SFP transceivers are static sensitive. To prevent ESD damage, wear an ESD-preventive wrist strap
that is connected to the chassis.
Do not remove and insert a transceiver more often than is necessary. Repeated removals and
insertions can shorten its useful life.
Keep all optical connections covered when not in use. If they become dusty, clean before using to
prevent dust from scratching the fiber-optic cable ends.
Do not touch ends of connectors to prevent fingerprints and other contamination.
Clean regularly; the required frequency of cleaning depends upon the environment. In addition,
clean connectors if they are exposed to dust or accidentally touched. Both wet and dry cleaning
techniques can be effective; refer to your site’s fiber-optic connection cleaning procedure.
Inspect routinely for dust and damage. If damage is suspected, clean and then inspect fiber ends
under a microscope to determine if damage has occurred.
Send documentation comments to mdsfeedback-doc@cisco.com.
C-1
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
APPENDIX
C
Cabinet and Rack Installation
This appendix provides information on the cabinet and rack installation and includes the following
sections:
Cabinet and Rack Requirements, page C-1
Cisco MDS 9000 Family Telco and EIA Shelf Bracket, page C-6
Cisco MDS 9500 Shelf Bracket, page C-13
Cabinet and Rack Requirements
This section provides the Cisco MDS 9000 Family requirements for the following types of cabinets and
racks, assuming an external ambient air temperature range of 32 to 104oF (0 to 40oC):
Standard perforated cabinets
Solid-walled cabinets with a roof fan tray (bottom to top cooling)
Standard open racks
Two-post telco racks
Note If you are selecting an enclosed cabinet, We recommend one of the thermally validated types: standard
perforated or solid-walled with a fan tray.
General Requirements for Cabinets and Racks
The cabinet or rack must be one of the following types:
Standard 19-inch four-post EIA cabinet or rack, with mounting rails that conform to English
universal hole spacing per section 1 of ANSI/EIA-310-D-1992. See the “Requirements Specific to
Perforated Cabinets” section on page C-3 and the “Requirements Specific to Solid-Walled
Cabinets” section on page C-4.
Standard two-post telco rack, with mounting rails that conform to English universal hole spacing per
section 1 of ANSI/EIA-310-D-1992. See the “Requirements Specific to Two-Post Telco Racks” section
on page C-6.
Send documentation comments to mdsfeedback-doc@cisco.com.
C-2
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cabinet and Rack Requirements
Cabinet and Rack Requirements for the Cisco MDS 9513 Chassis
The cabinet or rack must also meet the following requirements for the Cisco MDS 9513 chassis:
The minimum vertical rack space per chassis:
Cisco MDS 9513 chassis: 24.5 inches (62.2 cm) or 14 RU, height with required rack mount
support is 15 RU.
The distance between the rack-mounting rails for four-post EIA racks must be at least 26.56 inches
(67.46 cm). For more information, see “Installing the Cisco MDS 9513 Director in a Rack” section
on page 2-7.
The minimum spacing for four-post EIA cabinets (perforated or solid-walled):
To ensure the minimum bend radius for fiber-optic cables, the front mounting rails of the cabinet
should be offset from the front door by a minimum of 3 inches (7.6 cm), and a minimum of
5 inches (12.7 cm) if cable management brackets are installed on the front of the chassis.
A minimum of 4.0 inches (10.16 cm) of clear space between the side edge of the chassis and the
side wall of the cabinet. No sizeable flow obstructions should be immediately in the way of the
chassis air intake or exhaust vents.
Note Optional jumper power cords are available for use in a cabinet. See the “Jumper Power Cord” section on
page E-11.
Cabinet and Rack Requirements for the Cisco MDS 9509 and Cisco MDS 9506 Chassis
The cabinet or rack must also meet the following requirements:
The minimum vertical rack space per chassis:
Cisco MDS 9509 chassis: 24.5 inches (62.2 cm) or 14 RU
Cisco MDS 9506 chassis: 12.25 inches (31.1 cm) or 7 RU (rack unit)
The width between the rack-mounting rails must be at least 17.75 inches (45.1 cm). For four-post
EIA racks, this is the distance between the two front rails and rear rails.
The minimum spacing for four-post EIA cabinets (perforated or solid-walled):
To ensure the minimum bend radius for fiber-optic cables, the front mounting rails of the cabinet
should be offset from the front door by a minimum of 3 inches (7.6 cm), and a minimum of
5 inches (12.7 cm) if cable management brackets are installed on the front of the chassis.
A minimum of 2.5 inches (6.4 cm) of clear space between the side edge of the chassis and the
side wall of the cabinet. No sizeable flow obstructions should be immediately in the way of the
chassis air intake or exhaust vents.
Note Optional jumper power cords are available for use in a cabinet. See the “Jumper Power Cord” section on
page E-11.
Send documentation comments to mdsfeedback-doc@cisco.com.
C-3
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cabinet and Rack Requirements
Requirements Specific to Perforated Cabinets
A perforated cabinet is defined here as a cabinet with perforated front and rear doors and solid side walls.
In addition to the requirements listed in the “General Requirements for Cabinets and Racks” section on
page C-1, perforated cabinets must meet the requirements listed under Perforated Cabinet Requirements
for the Cisco MDS 9513 Chassis.
Perforated Cabinet Requirements for the Cisco MDS 9513 Chassis
The perforated cabinet requirements for the Cisco MDS 9513 chassis are as follows:
The front and rear doors must have at least a 60 percent open area (per square inch) perforation
pattern, with at least 80 percent perforated.
Cisco recommends that the roof should be solid.
Cisco recommends an open cabinet floor to enhance cooling.
A perforated cabinet that conforms to these requirements is available from Panduit Corporation:
Panduit Corporation
17301 South Ridgeland Avenue
Tinley Park, IL 60477
Contact: (708) 532-1800
Cabinet P/N: CN4-2
Cabinet description: Net-Access cabinet, 31.5 in. W X 40 in. D X 84 in. H (800 mm x 1017 mm x
2134 mm), 45 RU cable management on front and rear of front posts
A new cabinet that conforms to these requirements is available from Chatsworth Products:
Chatsworth Products, Inc.
31425 Agoura Road
Westlake Village, CA 91361
Customer Service and Technical Support phone number 800 834-4969
Cabinet: P/N: NF3K-113C-C42
Cabinet description: The N-Series TeraFrame Network Cabinet, 31.4 in. W X 40.4 in. D X 83.4 in.
H (798 mm x 1025 mm x 2118 mm), 45 RU
For more information see http://www.chatsworth.com/ciscoteraframe
Perforated Cabinet Requirements for the Cisco MDS 9509 and the Cisco MDS 9506 Chassis
The perforated cabinet requirements for the Cisco MDS 9506 and MDS 9509 chassis are as follows:
The front and rear doors must have at least a 60 percent open area perforation pattern, with at least
15 square inches of open area per rack unit of door height.
Cisco recommends that the roof should be perforated with at least a 20 percent open area.
Cisco recommends an open or perforated cabinet floor to enhance cooling.
Send documentation comments to mdsfeedback-doc@cisco.com.
C-4
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cabinet and Rack Requirements
A perforated cabinet that conforms to these requirements is available from Rittal Corporation:
Rittal Corporation
One Rittal Place
Springfield, OH 45504
Contact: (800) 477–4220
Cabinet P/N: Rittal 9969427
Cabinet description: PS-DK/OEM Cabinet Assembly, 78.7 in. (1998 mm) x 23.6 in. (600 mm) x
39.4 in. (1000 mm) (H x W x D) (42RU)
A new cabinet that conforms to these requirements is available from Panduit Corporation:
Panduit Corporation
17301 South Ridgeland Avenue
Tinley Park, IL 60477
Customer Service and Technical Support phone number: 800 777-3300.
Cabinet P/N: CN4-1
Cabinet description: Net-Access cabinet, 31.5 in. W X 40 in. D X 84 in. H (800 mm x 1017 mm x
2134 mm), 45 RU cable management on front and rear of front posts
For more information see http://www.panduit.com.
A new cabinet that conforms to these requirements is available from Chatsworth Products:
Chatsworth Products, Inc.
31425 Agoura Road
Westlake Village, CA 91361
Customer Service and Technical Support phone number 800 834-4969
Cabinet: P/N: NF2K-113C-C42
Cabinet description: The N-Series TeraFrame Network Cabinet, 31.4 in. W X 40.4 in. D X 83.4 in.
H (798 mm x 1025 mm x 2118 mm), 45 RU
For more information see: http://www.chatsworth.com/ciscoteraframe
Note Do not use the perforated cabinet from Rittal Corporation with the Cisco MDS 9513 Director.
Requirements Specific to Solid-Walled Cabinets
A solid-walled cabinet is defined here as a cabinet with solid (nonperforated) front and rear doors and
solid side walls. In addition to the requirements listed in the “General Requirements for Cabinets and
Racks” section on page C-1, solid-walled cabinets must meet the following requirements:
Solid-Walled Cabinet Requirements for the Cisco MDS 9513 Chassis
The solid-walled cabinet requirements for the Cisco MDS 9513 chassis are as follows:
Perforated front and back doors and solid or open side panels.
Send documentation comments to mdsfeedback-doc@cisco.com.
C-5
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cabinet and Rack Requirements
A recommended cabinet depth of 36 to 42 inches (91.4 to 106.7 cm) to allow the doors to close and
adequate airflow.
Bottom of cabinet should be open to enhance airflow.
The lowest piece of equipment should be installed a minimum of 1.75 inches (4.4 cm) above the
floor openings to prevent blocking the floor intake.
Solid-Walled Cabinet Requirements for the Cisco MDS 9509 and the Cisco MDS 9506 Chassis
The solid-walled cabinet requirements for the Cisco MDS 9509 and the Cisco MDS 9506 chassis are as
follows:
A roof-mounted fan tray and an air cooling scheme in which the fan tray pulls air in at the bottom
of the cabinet and exhausts it out the top, with a minimum of 500 cfm of airflow exiting the cabinet
roof through the fan tray.
Nonperforated (solid and sealed) front and back doors and side panels so that air travels predictably
from bottom to top.
A recommended cabinet depth of 36 to 42 inches (91.4 to 106.7 cm) to allow the doors to close and
adequate airflow.
A minimum of 150 square inches (968 sq. cm) of open area at the floor air intake of the cabinet.
The lowest piece of equipment should be installed a minimum of 1.75 inches (4.4 cm) above the
floor openings to prevent blocking the floor intake.
Requirements Specific to Standard Open Racks
In addition to the requirements listed in the “General Requirements for Cabinets and Racks” section on
page C-1, if mounting the chassis in an open rack (no side panels or doors), ensure that the rack meets
the following requirements:
The minimum width between two front mounting rails must be 17.75 inches (45.1 cm).
The minimum vertical rack space per chassis:
Cisco MDS 9513 chassis: 24.5 inches (62.2 cm) or 14 RU.
Cisco MDS 9509 chassis: 24.5 inches (62.2 cm) or 14 RU.
Cisco MDS 9506 chassis: 12.25 inches (31.1 cm) or 7 RU.
Note The rack-mount support brackets provided with the Cisco MDS 9513 Director require an
additional height of 0.75 inches (1.9 cm). They are required during the installation of the Cisco
MDS 9513 Director and cannot be removed.
Note The side rail-mount brackets provided with the Cisco MDS 9509 Director require an additional
height of 0.75 inches (1.9 cm). They are required during the installation of the Cisco MDS 9509
Director only, and can be removed or left installed once the front rack-mount brackets are
securely fastened to the rack-mounting rails.
Note The Cisco MDS 9506 Director does not require shelf brackets.
Send documentation comments to mdsfeedback-doc@cisco.com.
C-6
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cisco MDS 9000 Family Telco and EIA Shelf Bracket
The horizontal distance between the chassis and any adjacent chassis should be 6 inches (15.2 cm),
and the distance between the chassis air vents and any walls should be 2.5 inches (6.4 cm).
Requirements Specific to Two-Post Telco Racks
In addition to the requirements listed in the “General Requirements for Cabinets and Racks” section on
page C-1, two-post telco racks must meet the following requirements:
The minimum width between the two rack-mounting rails must be at least 17.75 inches (45.1 cm).
The distance between the chassis air vents and any walls should be 2.5 inches (6.4 cm).
Note Two-post telco racks are not intended for use with the Cisco MDS 9513 Director.
Cisco MDS 9000 Family Telco and EIA Shelf Bracket
The optional telco and EIA shelf bracket kit (DS-SHELF) can temporarily or permanently support the
Cisco MDS 9200 Series during installation. After the front rack-mount brackets are securely attached to the
rack-mounting rails, the shelf bracket can be removed. This kit supports the following configurations:
A Cisco MDS 9506 Director in a two-post telco rack
A Cisco MDS 9506 Director in a four-post EIA rack
Note This kit is not intended for use with a Cisco MDS 9509 Director in a two-post telco rack nor with a Cisco
MDS 9513 Director in any rack.
This section describes the procedure for installing a Cisco MDS 9000 Family switch in a rack or a
cabinet using the optional telco and EIA shelf bracket kit. It includes the following information:
Rack-Mounting Guidelines, page C-7
Before Installing the Rack-Mount Support Brackets, page C-7
Before Installing the Shelf Brackets, page C-8
Installing the Shelf Bracket Kit into a Two-Post Telco Rack, page C-9
Installing the Shelf Bracket Kit into a Four-Post EIA Rack, page C-10
Installing the Switch on the Rack-Mount Support Brackets, page C-11
Installing the Switch on the Shelf Brackets, page C-12
Removing the Shelf Bracket Kit (Optional), page C-12
Note This optional kit is not provided with the switch; to order the kit, contact your switch supplier.
Send documentation comments to mdsfeedback-doc@cisco.com.
C-7
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cisco MDS 9000 Family Telco and EIA Shelf Bracket
Rack-Mounting Guidelines
Caution If the rack is on wheels, ensure that the brakes are engaged or the rack is otherwise stabilized.
Caution If installing this kit in an EIA rack, attach the switch to all four rack-mounting rails; the EIA rails may
not be thick enough to prevent flexing of the shelf brackets if only two rails are used.
Before rack-mounting the chassis, ensure that the cabinet or the rack meets the following requirements:
The specifications listed in the “Cabinet and Rack Requirements” section on page C-1.
The depth of the rack between the front-mounting and rear-mounting rails is at least 18 in. (45.7 cm)
but less than or equal to 30 in. (76.2 cm). This is specific to four-post EIA cabinets or racks.
The airflow and cooling are adequate and there is sufficient clearance around the air vents on the
switch, as described in Appendix D, “Technical Specifications. This is particularly important to
verify if you are installing the switch in an enclosed cabinet.
The rack has sufficient vertical clearance for the chassis plus 2 RU for the shelf brackets, and any
desired clearance for the installation process.
The rack meets the minimum rack load ratings per rack unit listed in the following table:
Before Installing the Rack-Mount Support Brackets
Before installing the rack-mount support brackets for the Cisco MDS 9513 Director, check the contents
of your kit. Table C-1 lists the contents of the optional shelf bracket kit.
Rack Type MDS 9513 MDS 9509 MDS 9506
MDS 9222i
MDS 9216i
MDS 9216A MDS 9100
EIA (4-Post)
45 lb
(20.41 kg)
45 lb
(20.41 kg)
30 lb
(13.61 kg)
15 lb
(6.8 kg)
7.5 lb
(3.4 kg)
Telco (2-Post)
Do not use. Do not use. 60 lb
(27.22 kg)
30 lb
(13.61 kg)
15 lb
(6.8 kg)
Ta b l e C-1 Contents of Shelf Bracket Kit
Quantity Part Description
2Support rack-mount bracket
2Rack-mount support brace
20 12-24 x 3/4-in. Phillips screws
20 10-32 x 3/4-in. Phillips screws
Send documentation comments to mdsfeedback-doc@cisco.com.
C-8
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cisco MDS 9000 Family Telco and EIA Shelf Bracket
Before Installing the Shelf Brackets
Before installing the shelf brackets, check the contents of your kit. Table C-2 lists the contents of the
optional shelf bracket kit.
Required Equipment
You need the following equipment for this installation:
Number 2 Phillips screwdriver
Tape measure and level (to ensure shelf brackets are level)
Ta b l e C-2 Contents of Shelf Bracket Kit
Quantity Part Description
2Slider brackets
2Shelf brackets
1Crossbar
210-32 x 3/8-in. Phillips pan-head screws
16 12-24 x 3/4-in. Phillips screws
16 10-24 x 3/4-in. Phillips screws
Send documentation comments to mdsfeedback-doc@cisco.com.
C-9
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cisco MDS 9000 Family Telco and EIA Shelf Bracket
Installing the Shelf Bracket Kit into a Two-Post Telco Rack
Figure C-1 shows the installation of the shelf bracket kit into a two-post telco rack.
Figure C-1 Installing the Shelf Bracket Kit into a Two-Post Telco Rack
To install the shelf brackets in a two-post telco rack, follow these steps:
Step 1 Position a shelf bracket inside a rack-mounting rail as shown in Figure C-1. Align the screw holes at the
front of the shelf bracket with the holes in the rack-mounting rail. Then attach the shelf bracket to the
rack-mounting rail using a minimum of four 12-24 or 10-24 screws.
Note The bottom hole of the shelf bracket should align with the bottom hole of a rack unit on the
rack-mounting rail (the hole immediately above the 1/2-in. spacing).
Step 2 Repeat with the other shelf bracket.
Step 3 Verify that the shelf brackets are at the same height (using the level or tape measure as desired).
Step 4 Attach the crossbar to the rear of the shelf brackets as shown in Figure C-1, using the 10-32 screws.
1Rack-mounting rail (2x) 310-32 screws (2x)
2Shelf bracket (2x) 4Crossbar
1
2
3
4
Send documentation comments to mdsfeedback-doc@cisco.com.
C-10
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cisco MDS 9000 Family Telco and EIA Shelf Bracket
Installing the Shelf Bracket Kit into a Four-Post EIA Rack
Figure C-2 shows the installation of the shelf bracket kit into a four-post EIA rack.
Figure C-2 Installing the Shelf Bracket Kit into an EIA Rack
To install the shelf brackets in an EIA rack, follow these steps:
Step 1 Position a shelf bracket inside the rack-mounting rails as shown in Figure C-2. Align the screw holes at
the front of the shelf bracket with the holes in the front rack-mounting rail. Then attach the shelf bracket
to the front rack-mounting rail using a minimum of four 12-24 or 10-24 screws.
Note The bottom hole of the shelf bracket should align with the bottom hole of a rack unit on the
rack-mounting rail (the hole immediately above the 1/2-in. spacing).
Step 2 Repeat with the other shelf bracket.
Step 3 Verify that the shelf brackets are at the same height (using the level or tape measure as desired).
1Rack-mounting rail (4x) 4Crossbar
2Shelf bracket (2x) 510-32 screws (2x)
3Slider rail (2)
1
2
3
5
4
105087
Send documentation comments to mdsfeedback-doc@cisco.com.
C-11
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cisco MDS 9000 Family Telco and EIA Shelf Bracket
Step 4 Attach the crossbar to the shelf brackets as shown in Figure C-2, using the 10-32 screws.
Step 5 Insert the slider rails into the shelf brackets as shown in Figure C-2. Then attach them to the rear
rack-mounting rails using a minimum of four 12-24 or 10-24 screws.
Installing the Switch on the Rack-Mount Support Brackets
This section provides general instructions for installing the switch on top of the rack-mount support
brackets. For detailed installation instructions, see the “Installing the Chassis in a Cabinet or Rack”
section on page 2-6.
Warning
This unit is intended for installation in restricted access areas. A restricted access area can be
accessed only through the use of a special tool, lock and key, or other means of security.
Statement 1017
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Note Before you install, operate, or service the system, see the Regulatory Compliance and Safety Information
for the Cisco MDS 9000 Family for important safety information.
To install the switch on top of the rack-mount support brackets, follow these steps:
Step 1 Verify that the rack-mount support brackets are level and securely attached to the rack-mounting rails,
the support rack mount support brace is securely attached to the brackets, and the rack is stabilized.
Step 2 Slide a mechanical lift under the switch and lift the switch up onto the rack-mount support brackets,
ensuring it is squarely positioned.
Step 3 Attach the switch to the rack-mounting rails. See the “Installing the Chassis in a Cabinet or Rack”
section on page 2-6.
Caution We recommend grounding the chassis, even if the rack is already grounded. There is a
grounding pad with two threaded M4 holes on the chassis for attaching a grounding lug.
Send documentation comments to mdsfeedback-doc@cisco.com.
C-12
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cisco MDS 9000 Family Telco and EIA Shelf Bracket
Installing the Switch on the Shelf Brackets
This section provides general instructions for installing the switch on top of the shelf brackets. For
detailed installation instructions, see the “Installing the Chassis in a Cabinet or Rack” section on
page 2-6.
Warning
This unit is intended for installation in restricted access areas. A restricted access area can be
accessed only through the use of a special tool, lock and key, or other means of security.
Statement 1017
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Note Before you install, operate, or service the system, see the Regulatory Compliance and Safety Information
for the Cisco MDS 9000 Family for important safety information.
To install the switch on top of the shelf brackets, follow these steps:
Step 1 Verify that the shelf brackets are level and securely attached to the rack-mounting rails, the crossbar is
securely attached to the shelf brackets, and the rack is stabilized.
Step 2 Slide the switch onto the shelf brackets, ensuring it is squarely positioned.
Step 3 Attach the switch to the rack-mounting rails. See the “Installing the Chassis in a Cabinet or Rack”
section on page 2-6.
Caution Cisco recommends grounding the chassis, even if the rack is already grounded. There is a
grounding pad with two threaded M4 holes on the chassis for attaching a grounding lug.
Removing the Shelf Bracket Kit (Optional)
The shelf bracket kit can be removed once the Cisco MDS 9500 Series has been installed in a two-post
telco or four-post EIA rack, and the front rack-mount brackets are securely attached to the rack-mounting
rails. For additional support in an EIA rack, ensure that the C brackets on the Cisco MDS 9500 Series
are attached to the rear rack-mounting rails.
To remove the shelf bracket kit, follow these steps:
Step 1 Remove the screws fastening the slider brackets to the rear rack-mounting rails. Then slide the slider
brackets out of the shelf brackets.
Step 2 Remove the screws fastening the crossbar to the shelf brackets and remove the crossbar.
Send documentation comments to mdsfeedback-doc@cisco.com.
C-13
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cisco MDS 9500 Shelf Bracket
Step 3 Remove the screws fastening the shelf brackets to the front rack-mounting rails. Then remove the shelf
brackets from the rack.
Note This does not apply to the Cisco MDS 9513 Director.
Cisco MDS 9500 Shelf Bracket
Note This kit is optional and is not provided with the switch. To order the kit, contact your switch supplier.
The optional Cisco MDS 9500 Shelf Bracket Kit (DS-SHELF-9500) can be used to support the Cisco
MDS 9509 Director in a nonthreaded cabinet or rack with an 18-inch (45.7 cm) front to rear fixed rail
spacing. This shelf bracket kit can be used as a permanent support when installing a Cisco MDS 9509
Director in a cabinet or rack that meets the requirements listed in the “Cabinet and Rack Requirements”
section on page C-1.
Note Do not use this shelf bracket with the Cisco MDS 9513 Director.
Note Do not use this shelf bracket with the Cisco MDS 9506 Director.
Note This kit is not intended for use with a Cisco MDS 9509 Director in a two-post telco rack. This kit is also
not intended for use with any other product in the Cisco MDS 9000 Family.
This section describes the procedure for installing a Cisco MDS 9509 Director in a nonthreaded rack or
cabinet using the optional Cisco MDS 9500 Shelf Bracket Kit. It includes the following information:
Rack-Mounting Guidelines, page C-14
Before Installing the Shelf Brackets, page C-14
Installing the Cisco MDS 9500 Shelf Bracket Kit into a Cabinet or Rack, page C-15
Installing the Switch on the Shelf Brackets, page C-16
Send documentation comments to mdsfeedback-doc@cisco.com.
C-14
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cisco MDS 9500 Shelf Bracket
Rack-Mounting Guidelines
Caution If the rack is on wheels, ensure that the brakes are engaged or the rack is otherwise stabilized.
Before rack-mounting the chassis, ensure that the cabinet or the rack meets the following requirements:
The specifications listed in the “Cabinet and Rack Requirements” section on page C-1.
The depth of the rack between the front-mounting and rear-mounting rails is fixed at 18 inches
(45.7 cm).
The depth of the rack between the front-mounting and rear-mounting rails is fixed at 26.56 inches
(67.4 cm) for a Cisco MDS 9513 Director.
The cabinet or rack-mounting rails are nonthreaded.
The airflow and cooling are adequate and there is sufficient clearance around the air vents on the
Cisco MDS 9509 Director, as described in Appendix D, “Technical Specifications. This is
particularly important to verify if you are installing the switch in an enclosed cabinet.
The rack has sufficient vertical clearance for the chassis and any desired clearance for the
installation process. The Cisco MDS 9500 Shelf Bracket Kit does not consume any RU when
installed.
The rack meets the minimum rack load ratings of 45 lb (20.41 kg) per rack unit (RU) for the Cisco
MDS 9509 Director.
Before Installing the Shelf Brackets
Before installing the shelf brackets, check the contents of your kit. Table C-3 lists the contents of the
optional shelf bracket kit.
Required Equipment
You need the following equipment for this installation:
Number 2 Phillips screwdriver
Tape measure and level (to ensure shelf brackets are level)
Ta b l e C-3 Contents of Cisco MDS 9500 Shelf Bracket Kit
Quantity Part Description
2Shelf brackets
16 1/4-20 x 3/4 in. Phillips pan-head screws with lock washers
12 10-32 x 1/3 in. Phillips pan-head screws with lock washers
12 10-32 clip nuts
Send documentation comments to mdsfeedback-doc@cisco.com.
C-15
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cisco MDS 9500 Shelf Bracket
Installing the Cisco MDS 9500 Shelf Bracket Kit into a Cabinet or Rack
Figure C-3 shows the installation of the Cisco MDS 9500 Shelf Bracket Kit into a four-post rack.
Figure C-3 Installing the Shelf Bracket Kit into a Rack
To install the shelf brackets in a cabinet or rack, follow these steps:
Step 1 Position a shelf bracket inside the rack-mounting rails as shown in Figure C-3. Align the screw holes at
the front of the shelf bracket with the holes in the front rack-mounting rail, and then attach the shelf
bracket to the front rack-mounting rail using a minimum of four 1/4-20 screws.
Note The bottom hole of the shelf bracket should align with the bottom hole of a rack unit on the
rack-mounting rail (the hole immediately above the 1/2-inch spacing).
Step 2 Align the screw holes at the back of the shelf bracket with the holes in the back rack-mounting rail, and
then attach the shelf bracket to the back rack-mounting rail using a minimum of four 1/4-20 screws.
Step 3 Repeat Step 1 and Step 2 with the other shelf bracket.
Step 4 Verify that the shelf brackets are at the same height (using the level or tape measure as desired).
1120012
Send documentation comments to mdsfeedback-doc@cisco.com.
C-16
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix C Cabinet and Rack Installation
Cisco MDS 9500 Shelf Bracket
Installing the Switch on the Shelf Brackets
This section provides general instructions for installing the Cisco MDS 9509 Director on top of the shelf
brackets. For detailed installation instructions, see “Installing the Chassis in a Cabinet or Rack” section
on page 2-6.
Warning
This unit is intended for installation in restricted access areas. A restricted access area can be
accessed only through the use of a special tool, lock and key, or other means of security.
Statement 1017
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Note Before you install, operate, or service the system, see the Regulatory Compliance and Safety Information
for the Cisco MDS 9000 Family for important safety information.
To install the Cisco MDS 9509 Director on top of the shelf brackets, follow these steps:
Step 1 Verify that the shelf brackets are level and securely attached to the rack-mounting rails, and the rack is
stabilized.
Step 2 Slide the Cisco MDS 9509 Director onto the shelf brackets, ensuring it is squarely positioned.
Step 3 Attach the Cisco MDS 9509 Director to the rack-mounting rails. Slide the clip nuts over the holes on the
nonthreaded rails on the cabinet or rack. These clip nuts provide the threading for the screws that will
secure the chassis to the cabinet or rack. Use the 10-32 x 1/2 inch screws provided in this shelf bracket
kit to secure the chassis to the cabinet or rack. See “Installing the Chassis in a Cabinet or Rack” section
on page 2-6.
Caution We recommend grounding the chassis, although the rack is already grounded. There is a
grounding pad with two threaded M4 holes on the chassis for attaching a grounding lug.
Send documentation comments to mdsfeedback-doc@cisco.com.
D-1
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
APPENDIX
D
Technical Specifications
This appendix provides technical specifications and includes the following sections:
Switch Specifications, page D-1
Module Specifications, page D-4
Power Specifications for the Cisco MDS 9513 Director, page D-6
Power Specifications for the Cisco MDS 9509 Director, page D-9
Power Specifications for the Cisco MDS 9506 Director, page D-14
X2 Transceiver Specifications, page D-19
SFP and SFP+ Transceiver Specifications, page D-22
Note Specifications for cables and connectors are provided in Appendix E, “Cable and Port Specifications.
Switch Specifications
The Cisco MDS 9500 Series supports hot-swappable fan modules that provide 85 cfm (cubic feet per
minute) of airflow per slot with 410 W of power dissipation per slot.
Table D-1 lists the environmental specifications for the Cisco MDS 9500 Series.
Ta b l e D-1 Environmental Specifications for the Cisco MDS 9500 Series
Description Specification
Temperature, certified for operation 32 to 104°F (0 to 40°C)
Temperature, designed and tested for operation 32 to 130°F (0 to 55°C)
Temperature, ambient nonoperating and storage -40 to 158°F (-40 to 70°C)
Humidity (RH), ambient (noncondensing)
operating
10 to 90%
Humidity (RH), ambient (noncondensing)
nonoperating and storage
5 to 95%
Altitude, certified for operation 0 to 6500 ft (0 to 2000 m)
Altitude, designed and tested for operation -200 to 10000 ft (-60 to 3000 m)
Noise levels 70 dB
Send documentation comments to mdsfeedback-doc@cisco.com.
D-2
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Switch Specifications
Table D-2 lists the physical specifications for the Cisco MDS 9513 Director.
Table D-3 lists the physical specifications for the Cisco MDS 9509 Director.
Ta b l e D-2 Physical Specifications for the Cisco MDS 9513 Director
Description Specification
Dimensions
(HxWxD)
24.5 x 17.5 x 28 in. (62.2 x 44.5 x 71.1 cm)
Chassis requires 14 RU1, 15 RU with a rack-mount kit.
Chassis depth including cable guide is 33 in. (83.8 cm).
Crossbar module: 1.7 x 14.0 x 11.2 in. (4.4 x 35.6 x 28.4 cm)
1. RU = rack unit; 1 RU = 1.75 in. (4.45 cm).
Weight Chassis only: 101 lb (45.36 kg)
Fully loaded chassis2: 375 lb (170.10 kg)
System fan tray: 18 lbs (8.2 kg)
Crossbar module fan tray: 2.25 lbs (1.02 kg)
2. Depending on what modules are installed in the chassis.
Power supply 6000-W, AC input
33 lb (15 kg)
Airflow 275 to 325 lfm3 through system fan module, or 90 cfm4 per
supervisor, switching, or services module. Total of 1150 cfm if all
slots are filled.
Spacing requirements:
If installed in an open rack (no side panels), the horizontal
distance required between the chassis and any devices that
exhaust air towards the chassis is a minimum of 12 in. (304 cm),
and the distance required between the chassis air vents and any
walls is a minimum of 6 in. (15.2 cm).
3. lfm = linear feet per minute.
4. cfm = cubic feet per minute.
Ta b l e D-3 Physical Specifications for the Cisco MDS 9509 Director
Description Specification
Dimensions
(HxWxD)
24.5 x 17.25 x 18.8 in. (62.2 x 43.8 x 47.8 cm)
Chassis requires 14 RU1 plus space for shelf brackets.
Chassis depth including cable guide is 21.64 in. (55.0 cm).
Weight Chassis only: 55 lb (24.9 kg)
Chassis configured with two supervisor modules, and 2500-W
power supplies: 120 lb (54.4 kg)
Chassis configured with two supervisor modules, and 4000-W
power supplies: 140 lb (63.5 kg)
System fan tray: 10.5 lb (5.0 kg).
Send documentation comments to mdsfeedback-doc@cisco.com.
D-3
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Switch Specifications
Table D-4 lists the physical specifications for the Cisco MDS 9506 Director.
Power supply 4000-W, AC input
3000-W, AC input
2500-W, AC input
2500-W, DC input
Airflow 300 lfm2 through system fan module, or 80 cfm3 per supervisor,
switching, or services module. Total of 720 cfm if all slots are
filled.
Spacing requirements:
If installed in a cabinet, a minimum clearance of 2.5 in.
(6.4 cm) is required between the chassis air vents and the
cabinet walls.
If installed in an open rack (no side panels), the horizontal
distance required between the chassis and any devices that
exhaust air towards the chassis is a minimum of 6 in.
(15.2 cm), and the distance required between the chassis air
vents and any walls is a minimum of 2.5 in. (6.4 cm).
1. RU = rack unit; 1 RU = 1.75 in. (4.45 cm)
2. lfm = linear feet per minute
3. cfm = cubic feet per minute
Table D-3 Physical Specifications for the Cisco MDS 9509 Director (continued)
Description Specification
Ta b l e D-4 Physical Specifications for the Cisco MDS 9506 Director
Description Specification
Dimensions
(HxWxD)
12.25 x 17.37 x 21.75 in. (31.1 x 44.1 x 55.2 cm).
Chassis requires 7 RU1.
Chassis depth including cable guides is 26.75 inches (67.9 cm).
Weight Chassis only: 46 lb (20.9 kg).
Chassis configured with two supervisor modules, fan module,
and two power supplies: 86 lb (39 kg).
System fan tray: 7.70 lbs (3.49 kg)
1900W AC power supply: 11 lbs (4.99 kg)
Send documentation comments to mdsfeedback-doc@cisco.com.
D-4
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Module Specifications
Module Specifications
Table D-5 lists the specifications for the Cisco MDS 9500 Series supervisor modules, services modules,
and switching modules.
Power supply 1900-W, AC input
1900-W, DC input
Airflow 300 lfm2 through system fan module, or 80 cfm3 per supervisor,
switching, or services module (total of 480 cfm if all slots are
filled).
Spacing requirements:
If installed in a cabinet, a minimum of 2.5 in. (6.4 cm) is
required between the chassis air vents and the cabinet walls.
If installed in an open rack (no side panels), the horizontal
distance required between the chassis and any devices that
exhaust air towards the chassis is a minimum of 6 in.
(15.2 cm), and the distance required between the chassis air
vents and any walls is a minimum of 2.5 in. (6.4 cm).
1. RU = rack unit; 1 RU = 1.75 in. (4.45 cm)
2. lfm = linear feet per minute
3. cfm = cubic feet per minute
Table D-4 Physical Specifications for the Cisco MDS 9506 Director (continued)
Description Specification
Ta b l e D-5 Cisco MDS 9500 Series Module Specifications
Description Specification
Environmental Requirements
Temperature, certified for operation 32 to 104°F (0 to 40°C)
Temperature, designed and tested
for operation
32 to 130°F (0 to 55°C)
Temperature, ambient nonoperating
and storage
-40 to 167°F (-40 to 75°C)
Humidity (RH), ambient
(noncondensing) operating
10 to 90%
Altitude, certified for operation 0 to 6500 ft (0 to 2000 m)
Altitude, designed and tested for
operation
-200 to 10000 ft (-60 to 3000 m)
Physical Characteristics
Send documentation comments to mdsfeedback-doc@cisco.com.
D-5
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Module Specifications
Weight of Modules
Table D-6 lists the weight for each module in the Cisco MDS 9000 Family.
Dimensions 1.75 x15.5 x16.5 in. (4.4 x 39.4 x 41.9 cm)
Note These are the maximum
dimensions of the faceplate and
board, and include the connectors
on the board.
Weight 8 to 11.5 lb (1.4 to 5.2 kg)
Table D-5 Cisco MDS 9500 Series Module Specifications (continued)
Description Specification
Ta b l e D-6 Weight of Modules in the Cisco MDS 9000 Family
Module Weight
48-port 8-Gbps switching module 10.25 lb (4.65 kg)
24-port 8-Gbps switching module 10.25 lb (4.65 kg)
4/44-port 8-Gbps Host-Optimized
switching module
9.75 lb (4.42 kg)
Fabric 2 external crossbar module
(DS-13SLT-FAB2)
6 lb (2.7 kg)
Fabric 1 external crossbar module
(DS-13SLT-FAB1)
6 lb (2.7 kg)
48-port 4-Gbps switching module 11.0 lb (4.99 kg)
24-port 4-Gbps switching module 7.75 lb (3.52 kg)
12-port 4-Gbps switching module 7.5 lb (3.40 kg)
4-Port 10-Gbps switching module 8.5 lb (3.86 kg)
32-port FC switching module 9 lb (4.1 kg)
16-port FC switching module 9 lb (4.1 kg)
SSM 11 lb (5 kg)
ASM 11 lb (5 kg)
CSM 11.5 lb (5.2 kg)
IPS-8 10 lb (4.5 kg)
IPS-4 9 lb (4.1 kg)
MSM-18/4 8.5 lb (3.86 kg)
MSFM-18/4 8.5 lb (3.86 kg)
MPS-14/2 10 lb (4.5 kg)
Supervisor-2 for MDS 9500 Series 7.25 lb (kg)
Supervisor-1 for MDS 9500 Series 9 lb (4.1 kg)
Supervisor for MDS 9200 Series 9 lb (4.1 kg)
Send documentation comments to mdsfeedback-doc@cisco.com.
D-6
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Power Specifications for the Cisco MDS 9513 Director
Table D-7 lists the specifications for the batteries on the Cisco MDS 9000 Family caching services
module.
Note The CSM does not support Cisco SAN-OS Release 3.0(1).
Power Specifications for the Cisco MDS 9513 Director
This section includes the following topics:
Specifications for the Cisco MDS 9513 Power Supplies, page D-6
Component Power Requirements and Heat Dissipation for the Cisco MDS 9513 Director, page D-7
AC Power Consumption for the Cisco MDS 9513 Director, page D-8
Specifications for the Cisco MDS 9513 Power Supplies
The 6000-W AC power supply provides power based upon the input voltage. Each power supply has two
AC power connections and will provide power as follows:
One AC power connection @110 VAC = No output
Two AC power connection @110 VAC = 2900 W output
One AC power connection @ 220 VAC = 2900 W output
One AC power connection @110 VAC and one AC power connection @ 220 VAC = 2900 W output
Crossbar module fan tray 2.25 lb (1.13 kg)
Module blank panels 0.50 lb (0.25 kg)
Table D-6 Weight of Modules in the Cisco MDS 9000 Family (continued)
Module Weight
Ta b l e D-7 Caching Services Module Battery Specifications
Attribute Value
Nominal voltage 9.6 V
Rated capacity Typical discharge capacity at 0.2C rate: 2100 mAh
Minimum discharge capacity at 0.2C rate: 2000 mAh
Minimum discharge capacity at 5C rate: 1800 mAh
(1 V/cell discharge cut-off)
Discharge The battery is capable of continuous discharge from
41 to 140°F (5 to 60°C) at 5C-rate
Charge From 32 to 59°F (0 to 15°C) at C/10 rate and from 59
to 104°F (15 to 40°C) at C/2 rate
Storage temperature 32 to 95°F (0 to +35°C)
Relative humidity range From 5 to 90%
Send documentation comments to mdsfeedback-doc@cisco.com.
D-7
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Power Specifications for the Cisco MDS 9513 Director
Two AC power connection @ 220 VAC = 6000 W output
If a 110 VAC input is chosen, a 110-VAC power cord (CAB-7513AC=) must be ordered separately.
Note Power output does not include the power used by the individual modules used in the chassis.
Table D-8 lists the specifications for the Cisco MDS 9513 power supplies.
Component Power Requirements and Heat Dissipation for the Cisco MDS 9513
Director
Consider heat dissipation when sizing the air-conditioning requirements for an installation. The power
and heat associated with a Cisco MDS 9513 Director varies based upon the following considerations:
Power supply type
Switching module type and number of switching modules installed
Average switching traffic levels
Table D-9 lists the power requirements and heat dissipation for the components of the Cisco MDS 9513
Director.
Note Unless noted otherwise, the data listed in Table D-9 is based on worst-case conditions. Typical numbers
are approximately 30 percent below the numbers listed here.
Ta b l e D-8 Specifications for Cisco MDS 9513 Power Supplies
Description Specification
6000-W AC Power Supply
Type Autoranging input with power factor corrector.
Vo l t a g e 100 to 240 VAC (±10%).
Current rating 16 A maximum at 100 to 120 VAC and 2900-W output.
16 A maximum at 200 to 240 VAC and 6000-W output.
Frequency 50 to 60 Hz (nominal) (±3 Hz for full range).
Output capacity One AC power connection @110 VAC = No output
Two AC power connection @110 VAC = 2900 W output
One AC power connection @ 220 VAC = 2900 W output
One AC power connection @110 VAC and one AC power connection
@ 220 VAC = 2900 W output
Two AC power connection @ 220 VAC = 6000 W output
Output voltage at 110/120 3.3 V at 10 A, 50 V at 57 A
Output voltage at 200/240 3.3 V at 10A, 50 V at 119 A
Send documentation comments to mdsfeedback-doc@cisco.com.
D-8
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Power Specifications for the Cisco MDS 9513 Director
AC Power Consumption for the Cisco MDS 9513 Director
Table D-10 shows the typical AC power consumption for a Cisco MDS 9513 Director.
Ta b l e D-9 Requirements and Heat Dissipation for 6000-W AC Power Supplies
Module Type/
Product Number
NX-OS
Release
SAN-OS
Release
Power
Required
(watts)
Heat
Dissipation
(BTU/hr)
Input Current
90 VAC
(amps)
120 VAC
(amps)
180 VAC
(amps)
240 VAC
(amps)
Fan tray 1 (front panel),
DS-13SLT-FAN-F
3.x 248 1059 3.44 2.58 1.72 1.29
Fan tray 2 (rear panel),
DS-13SLT-FAN-R
3.x 70 299 0.97 0.73 0.49 0.36
Cisco MDS 9513 chassis,
DS-C9513, with front
(DS-13SLT-FAN-F) and rear
(DS-13SLT-FAN-R) fan trays
3.x 318 1358 4.41 3.31 2.21 1.65
Supervisor-2, DS-X9530-SF2-K9 3.x 126 538 1.75 1.31 0.88 0.66
48-port 4-Gbps switching module,
DS-X9148
3.x 185 790 2.57 1.93 1.28 0.96
24-port 4-Gbps switching module,
DS-X9124
3.x 147 628 2.04 1.53 1.02 0.77
12-port 4-Gbps switching module,
DS-X9112
3.x 132 564 1.83 1.38 0.92 0.69
4-Port 10-Gbps switching module,
DS-X9704
3.x 172 734 2.39 1.79 1.19 0.90
18/4 Multiservice module,
DS-X9304-18K9
3.2.(1) 200 855 2.78 2.08 1.39 1.04
Crossbar module, DS-13SLT-FAB1,
DS-13SLT-FAB2
3.x 63 269 0.88 0.66 0.44 0.33
48-port 8-Gbps switching module,
DS-X9248-96K9
4.x 298 1273 4.14 3.11 2.07 1.55
24-port 8-Gbps switching module,
DS-X9224-96K
4.x 273 1163 3.79 2.84 1.90 1.42
4/44-port 8-Gbps Host-Optimized
switching module,
DS-X9248-48K9
4.x 214 915 2.98 2.23 1.49 1.12
Send documentation comments to mdsfeedback-doc@cisco.com.
D-9
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Power Specifications for the Cisco MDS 9509 Director
Power Specifications for the Cisco MDS 9509 Director
This section includes the following topics:
Specifications for the Cisco MDS 9509 Power Supplies, page D-9
Component Power Requirements and Heat Dissipation for the Cisco MDS 9509 Director, page D-11
AC Power Consumption for the Cisco MDS 9509 Director, page D-14
Specifications for the Cisco MDS 9509 Power Supplies
The 3000-W AC power supply provides power based upon the input voltage, as follows:
Maximum of 1400 W at input of 100 to 120 VAC (1174 W available to modules and fans)
Maximum of 3000 W at input of 200 to 240 VAC (2774 W available to modules and fans)
The 2500-W AC power supply provides power based upon the input voltage, as follows:
Maximum of 1325 W at input of 100 to 120 VAC (1150 W available to modules and fans)
Maximum of 2525 W at input of 200 to 240 VAC (2331 W available to modules and fans)
If a 110-VAC input is chosen, a 110-VAC power cord (CAB-7513AC=) must be ordered separately.
Table D-11 lists the specifications for the Cisco MDS 9509 power supplies.
Ta b l e D-10 Typical AC Power Consumption for a Cisco MDS 9513 Director
Module Type / Product Number Typical AC Power Consumption (Watts)
Cisco MDS 9513 chassis, DS-C9513, with front
(DS-13SLT-FAN-F) and rear (DS-13SLT-FAN-R) fan trays,
two Supervisor-2 (DS-X9530-SF2-K9), and two crossbar
modules (DS-13SLT-FAB1 or DS-13SLT-FAB2)
697
48-port 4-Gbps switching module, DS-X9148 181
24-port 4-Gbps switching module, DS-X9124 127
12-port 4-Gbps switching module, DS-X9112 107
4-Port 10-Gbps switching module, DS-X9704 162
48-port 8-Gbps switching module, DS-X9248-96K9 230
24-port 8-Gbps switching module, DS-X9224-96K 221
4/44-port 8-Gbps Host-Optimized switching module,
DS-X9248-48K9
175
Ta b l e D-11 Specifications for Cisco MDS 9509 Power Supplies
Description Specification
2500-W AC Power Supply
Type Autoranging input with power factor corrector.
Vo l t a g e 100 to 240 VAC (±10%).
Send documentation comments to mdsfeedback-doc@cisco.com.
D-10
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Power Specifications for the Cisco MDS 9509 Director
Current rating 16 A maximum at 100 to 120 VAC and 1300-W output.
16 A maximum at 200 to 240 VAC and 2500-W output.
Note For current ratings of plugs, see Figure E-5 on page E-9.
Frequency 50 to 60 Hz (nominal) (±3 Hz for full range).
Output capacity 1325 W maximum (100 to 120 VAC ) .
2525 W maximum (200 to 240 VAC ) .
Output voltage at 110/120 3.3 V at 15 A; 5 V at 5 A; 12 V at 12 A; 42 V at 27.5 A.
Output voltage at 200/240 3.3 V at 1 5 A; 5 V at 5 A; 12 V at 12 A; 42 V at 55.5 A.
2500-W DC Power Supply
Vo l t a g e -48 VDC to -60 VDC continuous.
Current rating 70 A at -48 VDC; 55 A at -60 VDC; 80 A at -40.5 VDC.
Terminal block Accommodates 2 to 14 AWG copper conductors. Use 90°C
copper conductors for North American installations.
Note Actual size of the wire required is determined by the
installer or local electrician. Terminal block material is
rated at 302°F (150°C).
Output capacity 2525 W maximum (-48 to -60 VDC).
Output voltage 3.3 V at 15 A; 5 V at 5 A; 12 V at 12 A; 42 V at 55.5 A.
3000-W AC Power Supply
Type Autoranging input with power factor corrector.
Vo l t a g e 100 to 240 VAC (±10%).
Current rating 17.6 A maximum at 100 to 120 VAC and 1400-W output.
17.6 A maximum at 200 to 240 VAC and 3000-W output.
For current ratings of plugs, see Figure E-5 on page E-9
Frequency 50 to 60 Hz (nominal) (±3 Hz for full range).
Output capacity 1400 W maximum (100 to 120 VAC ) .
3000 W maximum (200 to 240 VAC ) .
Output voltage at 110/120 3.3 V at 15 A; 12 V at 12 A; 42 V at 27.9 A.
Output voltage at 200/240 3.3 V at 1 5 A; 12 V at 12 A; 42 V at 66 A.
4000-W AC Power Supply
Type High-line input with power factor corrector, 220 VAC,
single-phase circuit.
Vo l t a g e 200 to 240 VAC ( ±1 0% ).
Current rating 23 A
Note For current ratings of plugs, see Figure E-8 on page E-11.
Frequency 50/60 Hz (nominal) (±3% for full range).
Output capacity 4000 W maximum.
Output voltage at 200/240 3.3 V at 15 A; 5 V at 5 A; 12 V at 12 A; 42 V at 91.2 A
Table D-11 Specifications for Cisco MDS 9509 Power Supplies (continued)
Description Specification
Send documentation comments to mdsfeedback-doc@cisco.com.
D-11
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Power Specifications for the Cisco MDS 9509 Director
Component Power Requirements and Heat Dissipation for the Cisco MDS 9509
Director
When sizing the air-conditioning requirements for an installation, consider heat dissipation. The power
and heat associated with a Cisco MDS 9509 Director varies based upon the following considerations:
Power supply type
Switching module type and number of switching modules installed
Average switching traffic levels
Table D-12 and Table D-13 list the power requirements and heat dissipation for the components of the
Cisco MDS 9509 Director.
Note Unless noted otherwise, the data listed in Table D-12 and Table D-13 is based on worst-case conditions.
Typical numbers are approximately 30 percent below the numbers listed here.
Ta b l e D-12 Requirements and Heat Dissipation for 2500-, 3000-, and 4000-W AC Power Supplies
Module Type/
Product Number
NX-OS
Release
SAN-OS
Release
Power
Required
(watts)
Heat
Dissipation
(BTU/hr)
Input Current
90 VAC
(amps)
120 VAC
(amps)
180 VAC
(amps)
240 VAC
(amps)
Cisco MDS 9509 chassis with fan
module
DS-C9509
3.x 210 897 2.92 2.19 1.46 1.09
2.x and
1.x
216 920 3.00 2.25 1.50 1.13
Supervisor/fabric 1
DS-X9530-SF1
3.x 210 897 2.92 2.19 1.46 1.09
2.x and
1.x
220 940 3.05 2.29 1.53 1.15
Supervisor-2, DS-X9530-SF2-K9 3.x 126 538 1.75 1.31 0.88 0.66
48-port 4-Gbps switching module,
DS-X9148
3.x 185 790 2.57 1.93 1.28 0.96
2.x and
1.x
— — — —
24-port 4-Gbps switching module,
DS-X9124
3.x 147 628 2.04 1.53 1.02 0.77
2.x and
1.x
— — — —
12-port 4-Gbps switching module,
DS-X9112
3.x 132 564 1.83 1.38 0.92 0.69
2.x and
1.x
— — — —
4-Port 10-Gbps switching module,
DS-X9704
3.x 172 734 2.39 1.79 1.19 0.90
2.x and
1.x
— — — —
32-port 1-Gbps/2-Gbps Fibre
Channel module,
DS-X9032
3.x 191 816 .2.65 1.99 1.33 0.99
2.x and
1.x
200 855 2.78 2.08 1.39 1.04
Send documentation comments to mdsfeedback-doc@cisco.com.
D-12
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Power Specifications for the Cisco MDS 9509 Director
16-port 1-Gbps/2-Gbps Fibre
Channel module,
DS-X9016
3.x 210 897 2.92 2.19 1.46 1.09
2.x and
1.x
220 940 3.05 2.29 1.53 1.15
18/4 Multiservice module,
DS-X9304-18K9
3.2.(1) 200 855 2.78 2.08 1.39 1.04
MPS-14/2 module DS-X9302-14K9 3.x 200 854 2.78 2.08 1.39 1.04
2.x and
1.x
227 970 3.15 2.37 1.57 1.19
8-port IPS module
DS-X9308-SMIP
3.x 200 854 2.78 2.08 1.39 1.04
2.x and
1.x
220 940 3.05 2.29 1.53 1.15
4-port IPS module
DS-X9304-SMIP
3.x 160 683 2.22 1.67 1.11 0.83
2.x and
1.x
185 789 2.57 1.93 1.28 0.96
32-port SSM
DS-X9032-SSM
3.x 281 1200 3.90 2.93 1.95 1.46
2.x and
1.x
295 1260 4.10 3.07 2.05 1.54
32-port ASM
DS-X9032-SMV
3.x 281 1200 3.90 2.93 1.95 1.46
2.x and
1.x
295 1260 4.10 3.07 2.05 1.54
CSM
DS-X9560-SMC
3.x 200 854 2.78 2.08 1.39 1.04
2.x and
1.x
210 919 2.99 2.19 1.50 1.12
48-port 8-Gbps switching module,
DS-X9248-96K9
4.x 298 1273 4.14 3.11 2.07 1.55
24-port 8-Gbps switching module,
DS-X9224-96K
4.x 273 1163 3.79 2.84 1.90 1.42
4/44-port 8-Gbps Host-Optimized
switching module,
DS-X9248-48K9
4.x 214 915 2.98 2.23 1.49 1.12
Table D-12 Requirements and Heat Dissipation for 2500-, 3000-, and 4000-W AC Power Supplies (continued)
Module Type/
Product Number
NX-OS
Release
SAN-OS
Release
Power
Required
(watts)
Heat
Dissipation
(BTU/hr)
Input Current
90 VAC
(amps)
120 VAC
(amps)
180 VAC
(amps)
240 VAC
(amps)
Send documentation comments to mdsfeedback-doc@cisco.com.
D-13
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Power Specifications for the Cisco MDS 9509 Director
Ta b l e D-13 Power Requirements and Heat Dissipation for the 2500-W DC Power Supply
Module Type/
Product Number SAN-OS Release
Power
Required
(watts)
Heat
Dissipation
(BTU/hr)
Input Current
48 VDC
(amps)
60 VDC
(amps)
Cisco MDS 9509
chassis with fan module
DS-C9509
3.x 210 956 5.83 4.67
2.x and 1.x 216 983 6.00 4.80
Supervisor/fabric 1
DS-X9530-SF1
3.x 210 956 5.83 4.67
2.x and 1.x 220 1000 6.10 4.88
32-port 1-Gbps/2-Gbps Fibre Channel
module
DS-X9032
3.x 191 869 5.31 4.24
2.x and 1.x 200 911 5.56 4.45
16-port 1-Gbps/2-Gbps Fibre Channel
module
DS-X9016
3.x 210 956 5.83 4.67
2.x and 1.x 220 1000 6.10 4.88
MSM-18/4 module, DS-X9304-18K9 3.2(1) 200 855 2.78 2.08
MSFM-18/4 module, DS-X9304-18FK9 3.2(1) 200 855 2.78 2.08
MPS-14/2 module
DS-X9302-14K9
3.x 200 910 5.56 4.44
2.x and 1.x 227 970 3.15 2.37
8-port IPS module
DS-X9308-SMIP
3.x 200 910 5.56 4.44
2.x and 1.x 220 1000 6.10 4.88
4-port IPS module
DS-X9304-SMIP
3.x 160 728 4.44 3.56
2.x and 1.x 185 841 5.14 4.11
32-port SSM
DS-X9032-SSM
3.x 281 1279 7.81 6.24
2.x and 1.x 295 1342 8.19 6.56
32-port ASM
DS-X9032-SMV
3.x 281 1279 7.81 6.24
2.x and 1.x 295 1342 8.19 6.56
CSM
DS-X9560-SMC
3.x 200 910 5.56 4.44
2.x and 1.x 210 956 5.83 4.67
Send documentation comments to mdsfeedback-doc@cisco.com.
D-14
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Power Specifications for the Cisco MDS 9506 Director
AC Power Consumption for the Cisco MDS 9509 Director
Table D-14 shows the typical AC power consumption for the Cisco MDS 9509 Director
Power Specifications for the Cisco MDS 9506 Director
This section includes the following topics:
Specifications for the Cisco MDS 9506 Power Supplies, page D-15
Component Power Requirements and Heat Dissipation for the Cisco MDS 9506 Director, page D-16
AC Power Consumption for the Cisco MDS 9506 Director, page D-19
Ta b l e D-14 Typical AC Power Consumption for a Cisco MDS 9509 Director
Module Type / Product Number Typical AC Power Consumption (Watts)
Cisco MDS 9509 chassis, DS-C9509, with fan module, and
two Supervisor-2 (DS-X9530-SF2-K9)
380
Cisco MDS 9509 chassis, DS-C9509, with fan module, and
two Supervisor-1 (DS-X9530-SF1-K9)
622
48-port 4-Gbps switching module, DS-X9148 181
24-port 4-Gbps switching module, DS-X9124 127
12-port 4-Gbps switching module, DS-X9112 107
4-Port 10-Gbps switching module, DS-X9704 162
32-port 1-Gbps/2-Gbps Fibre Channel module, DS-X9032 174
16-port 1-Gbps/2-Gbps Fibre Channel module, DS-X9016 144
MPS-14/2 module, DS-X9302-14K9 178
32-port SSM, DS-X9032-SSM 211
8-port IPS module, DS-X9308-SMIP 175
4-port IPS module, DS-X9304-SMIP 128
48-port 8-Gbps switching module, DS-X9248-96K9 230
24-port 8-Gbps switching module, DS-X9224-96K 221
4/44-port 8-Gbps Host-Optimized switching module,
DS-X9248-48K9
175
Send documentation comments to mdsfeedback-doc@cisco.com.
D-15
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Power Specifications for the Cisco MDS 9506 Director
Specifications for the Cisco MDS 9506 Power Supplies
Caution The following applies to AC power supplies on the Cisco MDS 9506 only:
The DS-C9506 equipment is suitable for use on TN power systems and the IT-power system connection
of Norway (max 230 v phase-phase). If connected to a 230/400-V IT power system, beware of
high-leakage current. Earth connection is essential before connecting the supply.
The 1900-W AC power supply provides power based upon the input voltage:
Maximum of 1050 W at input of 100 to 120 VAC
Maximum of 1900 W at input of 200 to 240 VAC
A 110-VAC power cord (CAB-7513AC=) must be ordered separately.
Table D-15 lists the specifications for the Cisco MDS 9506 power supplies.
Ta b l e D-15 Specifications for Cisco MDS 9506 Power Supplies
Description Specification
1900-W AC Power Supply
Type Autoranging input with power factor corrector.
Vo l t a g e 100 to 240 VAC (±10%).
Current rating 12 A maximum at 100 to 120 VAC and 1050-W
output.
12 A maximum at 200 to 240 VAC and 1900-W
output.
Note For current ratings of plugs, see Figure E-5
on page E-9.
Frequency 50/60 Hz (nominal) (±3 Hz for full range).
Output capacity 1050 W maximum (at input of 100 to 120 VAC ) .
1900 W maximum (at input of 200 to 240 VAC ) .
Output voltage at 110/120 3.3 V at 2.5 A; 1.5 V at 15 A; 50 V at 20.4 A.
Output voltage at 200/240 3.3 V at 2.5 A; 1.5 V at 15 A; 50 V at 37.4 A.
1900-W DC Power Supply
Vo l t a g e -48 to -60 VDC continuous.
Current rating 50 A at -48 VDC, 40 A at -60 VDC, 60 A at -40.5
VDC.
Terminal block Accommodates 2 to 14 AWG copper conductors.
Use 90°C copper conductors for North American
installations.
Note Actual size of the wire required is
determined by the installer or local
electrician. Terminal block material is rated
at 302°F (150°C).
Output capacity 1900 W maximum (at input of -48 to -60 VDC).
Output voltage 3.3 V at 2.5 A; 1.5 V at 15 A; 50 V at 37.4 A.
Send documentation comments to mdsfeedback-doc@cisco.com.
D-16
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Power Specifications for the Cisco MDS 9506 Director
Component Power Requirements and Heat Dissipation for the Cisco MDS 9506
Director
When sizing the air-conditioning requirements for an installation, consider heat dissipation. The power
and heat associated with a Cisco MDS 9506 Director varies depending upon the following:
Power supply type
Switching module type and number of switching modules installed
Average switching traffic levels
Table D-16 and Table D-17 list the AC and DC power requirements and heat dissipation for the
components of the Cisco MDS 9506 Director.
Note Unless noted otherwise, the information listed in Table D-16 and Table D-17 is based on worst-case
conditions. Typical numbers are approximately 30 percent below the numbers listed here.
Ta b l e D-16 Power Requirements and Heat Dissipation for the 1900-W AC Power Supply
Module Type/
Product Number
NX-OS
Release
SAN-OS
Release
Power
Required
(watts)
Heat
Dissipation
(BTU/hr)
Input Current
90 VAC
(amps)
120 VAC
(amps)
180 VAC
(amps)
240 VAC
(amps)
Cisco MDS 9506 chassis with fan
module
DS-C9506
3.x 126 538 1.75 1.31 0.88 0.66
2.x and
1.x
126 538 1.75 1.32 0.88 0.66
Supervisor/fabric 1
DS-X9530-SF1
3.x 210 897 2.92 2.19 1.46 1.09
2.x and
1.x
220 940 3.05 2.29 1.53 1.15
Supervisor-2, DS-X9530-SF2-K9 3.x 126 538 1.75 1.31 0.88 0.66
48-port 4-Gbps switching module,
DS-X9148
3.x 185 790 2.57 1.93 1.28 0.96
2.x and
1.x
— — — —
24-port 4-Gbps switching module,
DS-X9124
3.x 147 628 2.04 1.53 1.02 0.77
2.x and
1.x
— — — —
12-port 4-Gbps switching module,
DS-X9112
3.x 132 564 1.83 1.38 0.92 0.69
2.x and
1.x
— — — —
4-Port 10-Gbps switching module,
DS-X9704
3.x 172 734 2.39 1.79 1.19 0.90
2.x and
1.x
— — — —
32-port 1-Gbps/2-Gbps Fibre
Channel module
DS-X9032
3.x 191 816 2.65 1.99 1.33 0.99
2.x and
1.x
200 855 2.78 2.08 1.39 1.04
Send documentation comments to mdsfeedback-doc@cisco.com.
D-17
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Power Specifications for the Cisco MDS 9506 Director
16-port 1-Gbps/2-Gbps Fibre
Channel module
DS-X9016
3.x 210 897 2.92 2.19 1.46 1.09
2.x and
1.x
220 940 3.05 2.29 1.53 1.15
18/4 Multiservice module,
DS-X9304-18K9
3.2.(1) 200 855 2.78 2.08 1.39 1.04
MPS-14/2 module
DS-X9302-14K9
3.x 200 854 2.78 2.08 1.39 1.04
2.x and
1.x
227 970 3.15 2.37 1.57 1.19
8-port IPS module
DS-X9308-SMIP
3.x 200 854 2.78 2.08 1.39 1.04
2.x and
1.x
220 940 3.05 2.29 1.53 1.15
4-port IPS module
DS-X9304-SMIP
3.x 160 683 2.22 1.67 1.11 0.83
2.x and
1.x
185 789 2.57 1.93 1.28 0.96
32-port SSM
DS-X9032-SSM
3.x 281 1200 3.90 2.93 1.95 1.46
2.x and
1.x
295 1260 4.10 3.07 2.05 1.54
32-port ASM
DS-X9032-SMV
3.x 281 1200 3.90 2.93 1.95 1.46
2.x and
1.x
295 1260 4.10 3.07 2.05 1.54
CSM
DS-X9560-SMC
3.x 200 854 2.78 2.08 1.39 1.04
2.x and
1.x
210 907 2.95 2.22 1.48 1.11
48-port 8-Gbps switching module,
DS-X9248-96K9
4.x 298 1273 4.14 3.11 2.07 1.55
24-port 8-Gbps switching module,
DS-X9224-96K
4.x 273 1163 3.79 2.84 1.90 1.42
4/44-port 8-Gbps Host-Optimized
switching module,
DS-X9248-48K9
4.x 214 915 2.98 2.23 1.49 1.12
Ta b l e D-17 Power Requirements and Heat Dissipation for the 1900-W DC Power Supply
Module Type/
Product Number SAN-OS Release
Power
Required
(watts)
Heat
Dissipation
(BTU/hr)
Input Current
48 VDC (amps) 60 VDC (amps)
Cisco MDS 9506
chassis with fan module
DS-C9506
3.x 126 573 3.50 2.80
2.x and 1.x 126 573 3.50 2.80
Table D-16 Power Requirements and Heat Dissipation for the 1900-W AC Power Supply (continued)
Module Type/
Product Number
NX-OS
Release
SAN-OS
Release
Power
Required
(watts)
Heat
Dissipation
(BTU/hr)
Input Current
90 VAC
(amps)
120 VAC
(amps)
180 VAC
(amps)
240 VAC
(amps)
Send documentation comments to mdsfeedback-doc@cisco.com.
D-18
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
Power Specifications for the Cisco MDS 9506 Director
Supervisor/fabric 1
DS-X9530-SF1
3.x 210 956 5.83 4.67
2.x and 1.x 220 1000 6.10 4.88
32-port 1-Gbps/2-Gbps
Fibre Channel module
DS-X9032
3.x 191 869 5.31 4.24
2.x and 1.x 200 911 5.56 4.45
16-port 1-Gbps/2-Gbps
Fibre Channel module
DS-X9016
3.x 210 956 5.83 4.67
2.x and 1.x 220 1000 6.10 4.88
18/4 Multiservice
module,
DS-X9304-18K9
3.2.(1) 200 855 2.78 2.08
MPS-14/2 module
DS-X9302-14K9
3.x 200 910 5.56 4.44
2.x and 1.x 227 970 3.15 2.37
8-port IPS module
DS-X9308-SMIP
3.x 200 910 5.56 4.44
2.x and 1.x 220 1000 6.10 4.88
4-port IPS module
DS-X9304-SMIP
3.x 160 728 4.44 3.56
2.x and 1.x 185 841 5.14 4.11
32-port SSM
DS-X9032-SSM
3.x 281 1279 7.81 6.24
2.x and 1.x 295 1342 8.19 6.56
32-port ASM
DS-X9032-SMV
3.x 281 1279 7.81 6.24
2.x and 1.x 295 1342 8.19 6.56
CSM
DS-X9560-SMC
3.x 200 910 5.56 4.44
2.x and 1.x 210 955 5.83 4.66
Table D-17 Power Requirements and Heat Dissipation for the 1900-W DC Power Supply (continued)
Module Type/
Product Number SAN-OS Release
Power
Required
(watts)
Heat
Dissipation
(BTU/hr)
Input Current
48 VDC (amps) 60 VDC (amps)
Send documentation comments to mdsfeedback-doc@cisco.com.
D-19
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
X2 Transceiver Specifications
AC Power Consumption for the Cisco MDS 9506 Director
Table D-18 shows the typical AC power consumption for the Cisco MDS 9506 Director.
X2 Transceiver Specifications
The Cisco MDS 9500 Series is compatible with X2 transceivers and cables that have SC connectors.
Each transceiver must match the transceiver on the other end of the cable in terms of wavelength, and
the cable must not exceed the stipulated cable length for reliable communications.
Use only Cisco X2 transceivers on the Cisco MDS 9500 Series Switches. Each Cisco X2 transceiver is
encoded with the model information that enables the switch to verify that the SFP transceiver meets the
requirements for the switch.
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance
and Safety Information for the Cisco MDS 9000 Family.
Ta b l e D-18 Typical AC Power Consumption for a Cisco MDS 9506 Director
Module Type / Product Number Typical AC Power Consumption (Watts)
Cisco MDS 9506 chassis, DS-C9506, with fan module, and
two Supervisor-2 (DS-X9530-SF2-K9)
395
Cisco MDS 9506 chassis, DS-C9506, with fan module, and
two Supervisor-1 (DS-X9530-SF1-K9)
624
48-port 4-Gbps switching module, DS-X9148 181
24-port 4-Gbps switching module, DS-X9124 127
12-port 4-Gbps switching module, DS-X9112 107
4-Port 10-Gbps switching module, DS-X9704 162
32-port 1-Gbps/2-Gbps Fibre Channel module, DS-X9032 174
16-port 1-Gbps/2-Gbps Fibre Channel module, DS-X9016 144
MPS-14/2 module, DS-X9302-14K9 178
32-port SSM, DS-X9032-SSM 211
8-port IPS module, DS-X9308-SMIP 175
4-port IPS module, DS-X9304-SMIP 128
48-port 8-Gbps switching module, DS-X9248-96K9 230
24-port 8-Gbps switching module, DS-X9224-96K 221
4/44-port 8-Gbps Host-Optimized switching module,
DS-X9248-48K9
175
Send documentation comments to mdsfeedback-doc@cisco.com.
D-20
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
X2 Transceiver Specifications
Cisco 10-Gbps Fibre Channel X2 Transceivers
Table D-19 lists the Cisco 10-Gbps Fibre Channel X2 transceivers.
General Specification for Cisco 10-Gbps Fibre Channel X2 Transceivers
Table D-20 provides the general specifications for Cisco 10-Gbps Fibre Channel X2 transceivers.
Note The minimum cable distance for all the transceivers, such as multimode fiber (MMF) and single-mode
fiber (SMF), except CX4 which is 2 meters (6.5 feet).
Environmental Conditions and Power Requirement Specifications for Cisco 10-Gbps Fibre Channel
X2 Transceivers
Table D-21 provides the power requirement specifications for Cisco 10-Gbps Fibre Channel X2
transceivers.
Ta b l e D-19 Cisco 10-Gbps Fibre Channel X2 Transceivers
Transceiver Module
Product Number Description Type
DS-X2-FC10G-SR 10-Gbps Fibre Channel SR, X2, SC Short Reach
DS-X2-FC10G-LR 10-Gbps Fibre Channel LR, X2, SC Long Reach
DS-X2-FC10G-ER 10-Gbps Fibre Channel ER, X2, SC Extended Reach
DS-X2-FC10G-CX4 10-Gbps Fibre Channel Copper, X2, CX4
Ta b l e D-20 General Specifications for the Cisco 10-Gbps Fibre Channel X2 Transceivers
X2
Wavelength
(nanometer) Fiber Type
Core Size
(micon)
Baud Rate
(GBd) Cable Distance
DS-X2-FC10G-SR 850 MMF 62.5 10.51875 33 m (108 ft)
50.0 (OM3) 10.51875 300 m (984 ft)
DS-X2-FC10G-LR 1310 SMF 9.0 10.51875 24.8 miles (40 km)
DS-X2-FC10G-ER 1550 SMF 9.0 10.51875 6.2 miles (10 km)
DS-X2-FC10G-CX4 Copper 10.51875 15 m (49.2 ft)
Ta b l e D-21 Power Requirement Specifications for Cisco 10-Gbps Fibre Channel X2 Transceivers
X2
Average Transmit
Power (dBm)
Average Receive
Power (dBm) Fiber Loss Budget (dBm)
Maximum Minimum Maximum Minimum
DS-X2-FC10G-SR -1.2 -7.3 -1.0 -9.9 2.6 (50.0 micron-OM3)
DS-X2-FC10G-LR 0.5 -8.2 0.5 -14.4 6.2
DS-X2-FC10G-ER 4.0 -4.7 -1.0 -15.8 11.1
Send documentation comments to mdsfeedback-doc@cisco.com.
D-21
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
X2 Transceiver Specifications
Note DS-X2-FC10G-CX4 is not an optical module; therefore, it is not listed in Table D-21.
Table D-22 provides the environmental specifications for the Cisco 10-Gbps Fibre Channel X2
transceivers.
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance
and Safety Information for the Cisco MDS 9000 Family.
Cisco 10-Gbps Ethernet X2 Transceivers
Table D-23 lists the Cisco 10-Gbps Ethernet X2 transceivers.
General Specification for Cisco 10-Gbps Ethernet X2 Transceivers
Table D-24 provides the general specifications for Cisco 10-Gbps Ethernet X2 transceivers.
Note The minimum cable distance for the MMF transceiver listed above is 2 meters (6.5 feet).
Ta b l e D-22 Environmental Specifications for the Cisco 10- Gbps Fibre Channel X2 Transceivers
X2 Operating Storage
Maximum Minimum Maximum Minimum
DS-X2-FC10G-SR 40°C 0°C 85°C -40°C
DS-X2-FC10G-LR 40°C 0°C 85°C -40°C
DS-X2-FC10G-ER 40°C 0°C 85°C -40°C
DS-X2-FC10G-CX4 40°C 0°C 85°C -40°C
Ta b l e D-23 Cisco 10-Gbps Ethernet X2 Transceivers
Transceiver Module
Product Number Description Type
DS-X2-E10G-SR 10-Gbps Ethernet Short Reach, X2, SC Short reach
Ta b l e D-24 General Specifications for the Cisco 10-Gbps Ethernet X2 Transceivers
X2
Wavelength
(nanometer) Fiber Type
Core Size
(micon)
Baud Rate
(GBd) Cable Distance
DS-X2-E10G-SR 850 MMF 62.5 10.312 33 (108 ft)
50.0 10.312 300 (984 ft)
Send documentation comments to mdsfeedback-doc@cisco.com.
D-22
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
Environmental and Power Requirements Specifications for Cisco 10-Gbps Ethernet X2 Transceiver
Table D-25 provides the power requirement specifications for the Cisco 10-Gbps Ethernet X2
transceiver.
Table D-26 provides the environmental specifications for the Cisco 10-Gbps Ethernet X2 transceivers.
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance
and Safety Information for the Cisco MDS 9000 Family.
Cisco 10-Gbps Ethernet DWDM X2 Transceiver
The Cisco 10-Gbps Ethernet DWDM X2 Transceiver pluggable module (DWDM-X2-xx.xx=) provides
high-performance Fibre Channel connectivity for the Cisco MDS 9000 family 10-Gbps Fibre Channel
switching module to an existing Ethernet DWDM infrastructure. The data format transmitted by the
Ethernet DWDM X2 transceiver on the fiber is identical to that transmitted by the Fibre Channel X2
transceiver, except that the Fibre Channel packets are clocked at the 10-Gigabit Ethernet rate.
The main features of the Cisco 10-Gbps Ethernet DWDM X2 Transceiver include:
Support for 32 nontunable ITU 100-GHz wavelengths compatible with the Cisco ONS DWDM
channel plan.
Support for digital optical monitoring capability.
For more information, refer to the data sheet at:
http://www.cisco.com/en/US/products/ps6576/index.html
SFP and SFP+ Transceiver Specifications
The Cisco MDS 9500 Series is compatible with SFP and SFP+ transceivers and cables that have LC
connectors. The wavelength of each transceiver must match the transceiver on the other end of the cable,
and the cable must not exceed the stipulated cable length for reliable communications.
Cisco SFP and SFP+ transceivers provide the uplink interfaces, laser transmit (TX) and laser receive
(RX), and support 850 to 1610 nm nominal wavelengths, depending upon the transceiver.
Ta b l e D-25 Power Requirement Specification for Cisco 10-Gbps Ethernet X2 Transceivers
X2
Average Transmit
Power (dBm)
Average Receive
Power (dBm)
Fiber Loss
Budget (dBm)
Maximum Minimum Maximum Minimum
DS-X2-E10G-SR -1.2 -7.3 -1.0 -9.9 2.6 (50.0
micron-OM3)
Ta b l e D-26 Environmental Specifications for Cisco 10-Gbps Ethernet X2 Transceiver
X2
Operating Storage
Maximum Minimum Maximum Minimum
DS-X2-E10G-SR 40°C 0°C 85°C -40°C
Send documentation comments to mdsfeedback-doc@cisco.com.
D-23
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
Use only Cisco SFP transceivers on the Cisco MDS 9500 Series. Each Cisco SFP transceiver is encoded
with model information that enables the switch to verify that the SFP transceiver meets the requirements
for the switch.
Note Generation 2 modules will not support 1-Gbps/2-Gbps SFPs. Generation 2 modules only support 4-Gbps
SFPs.
This section provides the following topics:
Cisco Fibre Channel SFP and SFP+ Transceivers, page D-23
Cisco Fibre Channel and Gigabit Ethernet Transceivers, page D-28
Cisco CWDM SFP Transceivers, page D-30
Cisco Gigabit Ethernet Transceivers, page D-34
Cisco DWDM SFP Transceivers, page D-34
Cisco Fibre Channel SFP and SFP+ Transceivers
Table D-27 lists the Cisco 2-Gbps and 4-Gbps SFP, and 8-Gbps SFP+ Fibre Channel transceivers.
Ta b l e D-27 Cisco 2-Gbps and 4-Gbps SFP, and 8-Gbps SFP+ Fibre Channel Transceivers
Transceiver Module
Product Number Description Type
DS-SFP-FC4G-SW 1/2/4-Gbps Fibre Channel SW, SFP, LC Short wavelength
DS-SFP-FC4G-MR 1/2/4-Gbps Fibre Channel LW 4-km, SFP, LC Long wavelength
DS-SFP-FC4G-LW 1/2/4-Gbps Fibre Channel LW 10-km, SFP, LC Long wavelength
DS-SFP-FC-2G-SW 1/2-Gbps Fibre Channel SW, SFP, LC Short wavelength
DS-SFP-FC-2G-LW 1/2-Gbps Fibre Channel LW, SFP, LC Long wavelength
DS-SFP-FC8G-SW 2/4/8-Gbps Fibre Channel SW, SFP+, LC Short wavelength
DS-SFP-FC8G-LW 2/4/8-Gbps Fibre Channel LW, SFP+, LC Long wavelength
Send documentation comments to mdsfeedback-doc@cisco.com.
D-24
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
General Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers
Table D-28 provides the general specifications for Cisco Fibre Channel SFP+ transceivers.
Environmental and Power Requirements for Cisco 8-Gbps Fibre Channel SFP+ Transceivers
Table D-29 provides the power specification for the Cisco 8-Gbps Fibre Channel SFP+ transceivers.
Ta b l e D-28 General Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers
SFP
Wavelength
(nanometer) Fiber Type
Core Size
(micon)
Baud Rate
(GBd)
Cable Distance
(meter)
DS-SFP-FC8G-SW 850 MMF 62.5 2.125 150 m (492 ft)
62.5 4.250 70 m (230 ft)
62.5 8.500 21 m (69 ft)
50.0 (OM2) 2.125 300 m (984 ft)
50.0 (OM2) 4.250 150 m (492 ft)
50.0(OM2) 8.500 50 m (164 ft)
50. 0 (OM3) 2.125 500 m (1640 ft)
50. 0 (OM3) 4.250 380 m (1246 ft)
50. 0 (OM3) 8.500 150 m (492 ft)
DS-SFP-FC8G-LW 1310 SMF 9.0 2.125 6.2 miles (10 km)
9.0 4.250 6.2 miles (10 km)
9.0 8.500 6.2 miles (10 km)
Ta b l e D-29 Power Requirements Specification for Cisco 8-Gbps Fibre Channel SFP+ Transceivers
SFP
Average Transmit
Power (dBm)
Average Receive
Power (dBm) Fiber Loss Budget (dBm)
Maximum Minimum Maximum Minimum
DS-SFP-FC8G-SW -1.3 -10 (2
Gbps)
-9 (4
Gbps)
-8.2 (8
Gbps)
0–62.5 micron
s
50.0
microns
[OM2]
50.0
microns
[OM3]
Send documentation comments to mdsfeedback-doc@cisco.com.
D-25
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
Table D-30 provides the environment specification for the Cisco 8-Gbps Fibre Channel SFP+
transceivers.
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance
and Safety Information for the Cisco MDS 9000 Family.
2.10 (2
Gbps)
1.78 (4
Gbps)
1.58 (8
Gbps)
2.62 (2
Gbps)
2.06 (4
Gbps)
1.68 (8
Gbps)
3.31 (2
Gbps)
2.88 (4
Gbps)
2.04 (8
Gbps)
DS-SFP-FC8G-LW –3 (2
Gbps)
–1 (4
Gbps)
+0.5 (8
Gbps)
–11.7 (2
Gbps)
–8.4 (4
Gbps)
–8.4 (8
Gbps)
–3 (2
Gbps)
–1 (4
Gbps)
+0.5 (8
Gbps)
7.8 (2 Gbps)
7.8 (4 Gbps)
6.4 (8 Gbps)
Table D-29 Power Requirements Specification for Cisco 8-Gbps Fibre Channel SFP+ Transceivers
(continued)
SFP
Average Transmit
Power (dBm)
Average Receive
Power (dBm) Fiber Loss Budget (dBm)
Maximum Minimum Maximum Minimum
Ta b l e D-30 Environmental Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers
SFP
Operating Storage
Maximum Minimum Maximum Minimum
DS-SFP-FC8G-SW 40°C 0°C 85°C -40°C
DS-SFP-FC8G-LW 40°C 0°C 85°C -40°C
Send documentation comments to mdsfeedback-doc@cisco.com.
D-26
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
General Specifications for Cisco 4-Gbps Fibre Channel SFP Transceivers
Table D-31 provides the general specifications for Cisco Fibre Channel SFP transceivers.
Note The minimum cable distance for all the transceivers, such as MMF and SMF, is 2 meters (6.5 feet).
Environmental and Power Requirement for Cisco 4-Gbps Fibre Channel SFP Transceivers
Table D-32 provides the power specification for the Cisco 4-Gbps Fibre Channel SFP transceivers.
Ta b l e D-31 General Specifications for Cisco 4-Gbps Fibre Channel SFP Transceivers
SFP
Wavelength
(nanometer) Fiber Type
Core Size
(micon)
Baud Rate
(GBd)
Cable Distance
(meter)
DS-SFP-FC4G-SW 850 MMF 62.5 1.0625 300 m (984 ft)
62.5 2.125 150 m (492 ft)
62.5 4.250 70 m (230 ft)
50.0 (OM2) 1.0625 500 m (1640 ft)
50.0 (OM2) 2.125 300 m (984 ft)
50.0(OM2) 4.250 150 m (492 ft)
50. 0 (OM3) 1.0625 860 m (2821 ft)
50. 0 (OM3) 2.125 500 m (1640 ft)
50. 0 (OM3) 4.250 380 m (1246 ft)
DS-SFP-FC4G-MR 1310 SMF 9.0 1.0625 6.2 miles (10 km)
9.0 2.125 2.4 miles (4 km)
9.0 4.250 2.4 miles (4 km)
DS-SFP-FC4G-LW 1310 SMF 9.0 1.0625 6.2 miles (10 km)
9.0 2.125 6.2 miles (10 km)
9.0 4.250 2.4 miles (4 km)
Ta b l e D-32 Power Requirement Specification for Cisco 4-Gbps Fibre Channel SFP Transceivers
SFP
Average Transmit
Power (dBm)
Average Receive
Power (dBm)
Fiber Loss Budget
(dBm)
Maximum Minimum Maximum Minimum
DS-SFP-FC4G-SW -2.5 -9 0 – 1.78 (62.5 micron),
2.06 (50 micron -
OM2), 2.88 (50
micron - OM3)
DS-SFP-FC4G-MR -3 -11.2 -1 4.8
DS-SFP-FC4G-LW -3 -8.4 -1.0 7.8
Send documentation comments to mdsfeedback-doc@cisco.com.
D-27
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
Table D-33 provides the environment specification for the Cisco 4-Gbps Fibre Channel SFP transceivers.
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance
and Safety Information for the Cisco MDS 9000 Family.
General Specifications for Cisco 2-Gbps Fibre Channel SFP Transceivers
Table D-34 provides general specification for the 4-Gbps Fibre Channel SFP transceiver.
Note The minimum cable distance for both the transceivers, such as MMF and SMF, is 2 meters (6.5 feet).
Environmental and Power Requirement for Cisco 2-Gbps Fibre Channel SFP Transceivers
Table D-35 provides the power specification for Cisco 2-Gbps Fibre Channel SFP transceivers.
Ta b l e D-33 Environmental Specifications for Cisco 4-Gbps Fibre Channel SFP Transceivers
SFP
Operating Storage
Maximum Minimum Maximum Minimum
DS-SFP-FC4G-SW 40°C 0°C 85°C -40°C
DS-SFP-FC4G-MR 40°C 0°C 85°C -40°C
DS-SFP-FC4G-LW 40°C 0°C 85°C -40°C
Ta b l e D-34 General Specifications for Cisco 4-Gbps Fibre Channel SFP Transceivers
SFP
Wavelength
(nanometer) Fiber Type
Core Size
(micon)
Baud Rate
(GBd)
Cable Distance
(meter)
DS-SFP-FC-2G-SW 850 MMF 62.5 1.0625 300 m (984 ft)
62.5 2.125 150 m (492 ft)
50.0 (OM2) 1.0625 500 m (1640 ft)
50.0 (OM) 2.125 300 m (984 ft)
DS-SFP-FC-2G-LW 1310 SMF 9.0 1.0625 6.2 miles (10 km)
9.0 2.125 6.2 miles (10 km)
Ta b l e D-35 Power Requirement Specification for Cisco 2-Gbps Fibre Channel SFP Transceivers
SFP
Average Transmit
Power (dBm)
Average Receive
Power (dBm)
Fiber Loss Budget
(dBm)
Maximum Minimum Maximum Minimum
DS-SFP-FC-2G-SW -2.5 -10.0 0 – 2.1
(62.5 micron),
2.62 (50 micron
-OM2)
DS-SFP-FC-2G-LW -3 -11.7 -3 7.8
Send documentation comments to mdsfeedback-doc@cisco.com.
D-28
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
Table D-36 provides the environmental specification for Cisco 2-Gbps Fibre Channel SFP transceivers.
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance
and Safety Information for the Cisco MDS 9000 Family.
Maximum Environmental and Electrical Ratings for Cisco Fibre Channel SFP Transceivers
Table D-37 provides the maximum environmental and electrical ratings for Cisco Fibre Channel SFP
transceivers.
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance
and Safety Information for the Cisco MDS 9000 Family.
Cisco Fibre Channel and Gigabit Ethernet Transceivers
Table D-38 lists the combination Fibre Channel/Gigabit Ethernet SFP transceivers.
Ta b l e D-36 Environmental Specifications for Cisco 2-Gbps Fibre Channel SFP Transceivers
SFP
Operating Storage
Maximum Minimum Maximum Minimum
DS-SFP-FC-2G-SW 40°C 0°C 85°C -40°C
DS-SFP-FC-2G-LW 40°C 0°C 85°C -40°C
Ta b l e D-37 Maximum Environmental and Electrical Ratings for Cisco Fibre Channel SFP
Transceivers
Parameter1
1. Do not operate outside the recommended operating conditions. Device reliability may be affected and damage to the
device may occur over an extended period of time.
Symbol Min. Max.2
2. Absolute maximum ratings are those values beyond which damage to the device may occur if these limits are
exceeded for other than a short period of time.
Unit Notes
Storage temperature TS-40 85 °C 1
Case temperature TC070 °C 1, 2
Relative humidity RH 595 % 1
Ta b l e D-38 Cisco Fibre Channel and Gigabit Ethernet SFP Transceivers
Transceiver Module
Product Number Description Type
DS-SFP-FCGE-LW 1-Gbps Ethernet and 1-Gbps/2-Gbps Fibre Channel-LW SFP,
LC
Long wavelength
DS-SFP-FCGE-SW 1-Gbps Ethernet and 1-Gbps/2-Gbps Fibre Channel-SW SFP,
LC
Short wavelength
Send documentation comments to mdsfeedback-doc@cisco.com.
D-29
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
General Specifications for Cisco Fibre Channel and Gigabit Ethernet SFP Transceivers
Table D-39 provides general specification for Cisco Fibre Channel and Gigabit Ethernet SFP transceiver.
Note The minimum cable distance for both the transceivers listed above (multimode fiber (MMF)) and
single-mode fiber (SMF) is 2 meters (6.5 feet).
Environmental and Power Requirement Specifications for Cisco Fibre Channel and Gigabit Ethernet
SFP Transceivers
Table D-40 provides the power requirement specification for Cisco Fibre Channel and Gigabit Ethernet
SFP transceivers.
Ta b l e D-39 General Specifications for Cisco Fibre Channel and Gigabit Ethernet SFP Transceivers
SFP
Wavelength
(nanometer) Fiber Type
Core Size
(micon)
Baud Rate
(GBd)
Cable Distance
(meter)
DS-SFP-FCGE-SW 850 MMF 62.5 1.0625 300 m (984 ft)
62.5 2.125 150 m (492 ft)
50.0 (OM2) 1.0625 500 m (1640 ft)
50.0 (OM2) 2.125 300 m (984 ft)
DS-SFP-FCGE-LW 1310 SMF 9.0 1.0625 6.2 miles (10 km)
9.0 2.125 6.2 miles (10 km)
Ta b l e D-40 Power Requirement Specification for Cisco Fibre Channel and Gigabit Ethernet SFP
Transceivers
SFP
Average Transmit
Power (dBm)
Average Receive
Power (dBm) Fiber Loss Budget (dBm)
Maximum Minimum Maximum Minimum
DS-SFP-FCGE-SW -1.2 -10.0 (FC)
-9.5 (GE)
0-17 (GE) 2.1 (FC - 62.5 micron), 2.62
(FC - 50.0 micron)
2.38 (GE - 62.5 micron),
3.37 (FC - 50.0 micron)
DS-SFP-FCGE-LW -3 -11.0 -3 -19 (GE) 7.8 (FC)
4.57 (GE)
Send documentation comments to mdsfeedback-doc@cisco.com.
D-30
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
Table D-41 provides the environmental specification for Cisco Fibre Channel and Gigabit Ethernet SFP
transceivers.
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance
and Safety Information for the Cisco MDS 9000 Family.
Cisco CWDM SFP Transceivers
Table D-42 lists the Cisco 1-Gbps and 2-Gbps CWDM SFP transceivers.
Ta b l e D-41 Environmental Specifications for Cisco Fibre Channel and Gigabit Ethernet SFP
Transceivers
SFP
Operating Storage
Maximum Minimum Maximum Minimum
DS-SFP-FCGE-SW 40°C 0°C 85°C -40°C
DS-SFP-FCGE-LW 40°C 0°C 85°C -40°C
Ta b l e D-42 Cisco 1-Gbps and 2-Gbps CWDM SFP Transceivers
Description Color
Cisco CWDM SFP 1470 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Gray
Cisco CWDM SFP 1490 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Violet
Cisco CWDM SFP 1510 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Blue
Cisco CWDM SFP 1530 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Green
Cisco CWDM SFP 1550 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Yellow
Cisco CWDM SFP 1570 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Orange
Cisco CWDM SFP 1590 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Red
Cisco CWDM SFP 1610 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Brown
Send documentation comments to mdsfeedback-doc@cisco.com.
D-31
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
Table D-43 lists the Cisco 4-Gbps CWDM SFP transceivers available through Cisco.
Environmental and Optical Specifications for Cisco 2-Gbps CWDM SFP Transceivers
Table D-44 provides the environmental specifications for the Cisco 2-Gbps CWDM SFP transceivers.
Ta b l e D-43 Cisco 4-Gbps CWDM SFP Transceivers
Description Color
DS-CWDM4G1470: Cisco MDS9000 1470 nm; CWDM 4-Gbps FC Gray
DS-CWDM4G1490: Cisco MDS9000 1490 nm; CWDM 4-Gbps FC Violet
DS-CWDM4G1510: Cisco MDS9000 1510 nm; CWDM 4-Gbps FC Blue
DS-CWDM4G1530: Cisco MDS9000 1530 nm; CWDM 4-Gbps FC Green
DS-CWDM4G1550: Cisco MDS9000 1550 nm; CWDM 4-Gbps FC Yel l ow
DS-CWDM4G1570: Cisco MDS9000 1570 nm; CWDM 4-Gbps FC Orange
DS-CWDM4G1590: Cisco MDS9000 1590 nm; CWDM 4-Gbps FC Red
DS-CWDM4G1610: Cisco MDS9000 1610 nm; CWDM 4-Gbps FC Brown
Ta b l e D-44 Environmental Specifications for Cisco 2-Gbps CWDM SFP Transceivers
SFP
Operating Storage
Maximum Minimum Maximum Minimum
All Cisco 2-Gbps
CWDM SFP
Transceivers
40°C 0°C 85°C -40°C
Send documentation comments to mdsfeedback-doc@cisco.com.
D-32
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
Table D-45 provides the optical specifications for the Cisco 2-Gbps CWDM SFP transceivers.
Note Parameters are specified over temperature and at end of life unless otherwise noted.
When shorted distances of single-mode fiber are used, it is necessary to insert an in-line optical
attenuator in the link to avoid overloading the receiver.
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance
and Safety Information for the Cisco MDS 9000 Family.
Ta b l e D-45 Optical Specification for Cisco 2-Gbps CWDM SFP Transceivers
Parameters Symbol Minimum Typical Maximum Units Notes/Conditions
Transmitter Center
Wavelength
λcx-4 x+7 nm Available center
wavelengths are
1470, 1490,
1510, 1530,
1550, 1570,
1590, and 1610
nm
Side-mode
Suppression Ratio
SMSR 30 ––dB
Transmitter Optical
Output Power
Pout 0.0 5.0 dBm Average power
coupled into
single-mode fiber
Receiver Optical
Input Power (BER
<10-12 with PRBS
2-7-1)
Pin -28.0 -7.0 dBm At 2.12 Gbps,
140°F (60°C)
case temperature
Receiver Optical
Input Power (BER
<10-12 with PRBS
2-7-1)
Pin -29.0 -7.0 dBm At 1.25 Gbps,
140°F (60°C)
case temperature
Receiver Optical
Input Wavelength
λin 1450 1620 nm
Transmitter
Extinction Ratio
OMI 9––dB
Dispersion Penalty at
62.1 miles (100 km)
––3dB At 2.12 Gbps
Dispersion Penalty at
62.1 miles (100 km)
––2dB At 1.25 Gbps
Send documentation comments to mdsfeedback-doc@cisco.com.
D-33
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
Environmental and Optical Specifications for Cisco 4-Gbps CWDM SFP Transceivers
Table D-46 provides the environmental specifications for the Cisco 4-Gbps CWDM SFP transceivers.
Table D-47 provides the optical specifications for Cisco 4-Gbps CWDM SFP transceivers.
Note In typical point-to-point deployments, all wavelengths have a minimum reach of 24.8 miles (40 km).
Parameters are specified over temperature and at end of life unless otherwise noted.
When shorted distances of single-mode fiber are used, it is necessary to insert an in-line optical
attenuator in the link to avoid overloading the receiver.
A maximum of 24 4-Gbps CWDM SFPs are supported in a single MDS switching module.
Ta b l e D-46 Environmental Specifications for Cisco 4-Gbps CWDM SFP Transceivers
SFP
Operating Storage
Maximum Minimum Maximum Minimum
All Cisco 4-Gbps
CWDM SFP
Transceivers
40°C 0°C 85°C -40°C
Ta b l e D-47 Optical Specification for Cisco 4-Gbps CWDM SFP Transceivers
Parameters Symbol Minimum Typical Maximum Units Notes/Conditions
Transmitter Center
Wavelength
λc(x-6) xx+6 nm Available center
wavelengths are
1470, 1490,
1510, 1530,
1550, 1570,
1590, and 1610
nm
Side-mode
Suppression Ratio
SMSR 30 ––dB
Transmitter Optical
Output Power
Pout 1.0 5.0 dBm Average power
coupled into
single-mode fiber
Receiver Optical
Input Power (BER
<10-12 with PRBS
2-23-1)
Pin -15.7 0.0 dBm 140°F (60°C)
case temperature
Link Budget 17.8 ––dB
Receiver Optical
Input Wavelength
λin 1450 1620 nm
Transmitter
Extinction Ratio
OMI 4––dB
Dispersion Penalty at
62.1 miles (100 km)
––3dB At 2.12 Gbps
Send documentation comments to mdsfeedback-doc@cisco.com.
D-34
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
When interoperating a Cisco 4-Gbps CWDM SFP transceiver with a Cisco 1/2-Gbps CWDM
transceiver, the speed of ports on the Cisco 4-Gbps CWDM SFP transceiver must be manually
configured to 1-Gbps or 2-Gbps.
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance
and Safety Information for the Cisco MDS 9000 Family.
Cisco Gigabit Ethernet Transceivers
A 1-Gbps Gigabit Ethernet SFP transceiver is provided on the Cisco MDS 9000 IPS modules.
Table D-48 lists the transceiver supported on the Cisco MDS 9216.
Note DS-SFP-GE-T is not supported on Cisco MDS 9222.
General Specifications for Cisco Gigabit Ethernet Transceivers
Table D-49 provides the general specification for the Cisco Gigabit Ethernet SFP transceiver.
Environmental and Power Requirement Specifications for Cisco Gigabit Ethernet Transceivers
Table D-50 provides the environmental specifications for the Cisco Gigabit Ethernet transceivers.
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance
and Safety Information for the Cisco MDS 9000 Family.
Cisco DWDM SFP Transceivers
The Cisco 2-Gbps DWDM SFP modules enable enterprises and service providers to provide scalable,
easy-to-deploy DWDM Fibre Channel services in their networks.
Ta b l e D-48 Cisco Gigabit Ethernet SFP Transceivers
Transceiver Module Product Number Description
DS-SFP-GE-T 1-Gbps Ethernet SFP
Ta b l e D-49 General Specification for the Cisco Gigabit Ethernet SFP Transceivers
SFP Cable Type Cable Distance
DS-SFP-GE-T Category 5 UTP 100 m (328 ft)
Ta b l e D-50 Environmental Specifications for Cisco Gigabit Ethernet Transceivers
SFP
Operating Storage
Maximum Minimum Maximum Minimum
DS-SFP-GE-T 40°C 0°C 85°C -40°C
Send documentation comments to mdsfeedback-doc@cisco.com.
D-35
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
The main features of the Cisco DWDM SFP include:
Support for International Telecommunication Union (ITU) 100-GHz wavelength grid.
Match for wavelength plan of Cisco ONS 100-GHz product family.
Fixed-wavelength SFP with 32 SFP models.
Note A single Cisco MDS 9000 family switching module supports up to eight 2-Gbps DWDM SFPs.
For more information, refer to the data sheet at:
http://www.cisco.com/en/US/prod/collateral/modules/ps5455/ps6576/product_data_sheet0900aecd805
82763.html.
Send documentation comments to mdsfeedback-doc@cisco.com.
D-36
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D Technical Specifications
SFP and SFP+ Transceiver Specifications
Send documentation comments to mdsfeedback-doc@cisco.com.
E-1
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
APPENDIX
E
Cable and Port Specifications
This appendix provides the cable and port specifications, and includes the following sections:
Cables and Adapters Provided, page E-1
Console Port, page E-2
COM1 Port, page E-3
MGMT 10/100/1000 Ethernet Port, page E-4
MGMT 10/100 Ethernet Port, page E-6
Supported Power Cords and Plugs, page E-7
Cables and Adapters Provided
The Cisco MDS 9500 Series accessory kit includes the following items:
RJ-45 rollover cable
DB-9F/RJ-45F PC—RJ-45 to DB-9 female DTE adapter (labeled “Terminal”)
RJ-45/DSUB F/F adapter—RJ-45 to DB-25 female DTE adapter (labeled Terminal”)
RJ-45/DSUB R/P adapter—RJ-45 to DB-25 male DCE adapter (labeled “Modem”)
Note Additional cables and adapters can be ordered from your customer service representative.
Note If you purchased Cisco support through a Cisco reseller, contact the reseller directly. If you purchased
support directly from Cisco Systems, contact Cisco Technical Support at this URL:
http://www.cisco.com/warp/public/687/Directory/DirTAC.shtm
Send documentation comments to mdsfeedback-doc@cisco.com.
E-2
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
Console Port
Console Port
The console port is an asynchronous RS-232 serial port with an RJ-45 connector. You can use the RJ-45
rollover cable and the RJ-45/DSUB F/F adapter or the DB-9F/RJ-45F PC terminal adapter to connect the
console port to a computer running terminal emulation software.
Console Port Pinouts
Table E-1 lists the pinouts for the console port on the Cisco MDS 9500 Series.
Connecting the Console Port to a Computer Using the DB-25 Adapter
You can use the RJ-45 rollover cable and RJ-45/DSUB F/F adapter (labeled “Terminal”) to connect the
console port to a computer running terminal emulation software. Table E-2 lists the pinouts for the
console port, the RJ-45 rollover cable, and the RJ-45/DSUB F/F adapter.
Ta b l e E-1 Console Port Pinouts
Pin Signal
11
1. Pin 1 is connected internally to pin 8.
RTS
2DTR
3TxD
4GND
5GND
6RxD
7DSR
8CTS
Ta b l e E-2 Port Mode Signaling and Pinouts with the DB-25 Adapter
Console Port RJ-45 Rollover Cable
RJ4-5/DSUB F/F
Terminal Adapter
Console
Device
Signal RJ-45 Pin RJ-45 Pin DB-25 Pin Signal
RTS 1 8 5 CTS
DTR 2 7 6 DSR
TxD 3 6 3 RxD
GND 4 5 7 GND
GND 5 4 7 GND
RxD 6 3 2 TxD
DSR 7 2 20 DTR
CTS 8 1 4 RTS
Send documentation comments to mdsfeedback-doc@cisco.com.
E-3
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
COM1 Port
Connecting the Console Port to a Computer Using the DB-9 Adapter
You can use the RJ-45 rollover cable and DB-9F/RJ-45F PC terminal (labeled “Terminal”) to connect
the console port to a computer running terminal emulation software. Table E-3 lists the pinouts for the
console port, the RJ-45 rollover cable, and the DB-9F/RJ-45F PC terminal.
COM1 Port
The COM1 port is a serial port with a DB-9 connector. The COM1 port can be connected to a modem
using the cable and adapters provided in the accessory kit.
COM1 Port Pinouts
Table E-4 lists the pinouts for the COM1 port on the Cisco MDS 9500 Series.
Note Additional cables and adapters can be ordered from your customer service representative.
Ta b l e E-3 Port Mode Signaling and Pinouts with the DB-9 Adapter
Console Port RJ-45 Rollover Cable
DB9F/RJ45F PC
Terminal
Console
Device
Signal RJ-45 Pin RJ-45 Pin DB-9 Pin Signal
RTS 1 8 8 CTS
DTR 2 7 6 DSR
TxD 3 6 2 RxD
GND 4 5 5 GND
GND 5 4 5 GND
RxD 6 3 3 TxD
DSR 7 2 4 DTR
CTS 8 1 7 RTS
Ta b l e E-4 COM1 Port Pinouts
Pin Signal
1DCD
2RxD
3TxD
4DTR
5GND
6DSR
7RTS
Send documentation comments to mdsfeedback-doc@cisco.com.
E-4
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
MGMT 10/100/1000 Ethernet Port
Connecting the COM1 Port to a Modem
You can use the DB-9F/RJ-45F PC terminal (labeled “Terminal”) to connect to the COM1 port, and the
RJ-45/DSUB R/P adapter (labeled “Modem”) to connect to the modem. You can use the RJ-45 rollover
cable to connect these adapters.
Table E-5 lists the pinouts for the COM1 port, the DB-9F/RJ-45F PC terminal, RJ-45 rollover cable, and
the RJ-45/DSUB R/P adapter.
MGMT 10/100/1000 Ethernet Port
The MGMT 10/100/1000 Ethernet port is an Ethernet port with an RJ-45 connector. You can use a
modular, RJ-45, straight-through UTP cable to connect the management port to an external hub, switch,
or router (see Figure E-1).
Figure E-1 RJ-45 Interface Cable Connector
8CTS
9RI
Table E-4 COM1 Port Pinouts (continued)
Pin Signal
Ta b l e E-5 Port Mode Signaling and Pinouts for Modem with DB-25 Connection
COM1 Port
DB-9F/RJ45F
PC terminal
RJ-45
Rollover Cable
RJ-45/DSUB R/P
Adapter Modem
Signal DB-9 Pin RJ-45 Pin RJ-45 Pin DB-25 Pin Signal
CTS 8 8 1 5 CTS
DSR 6 7 2 8 DCD
RxD 2 6 3 3 RxD
GND 5 5 4 7 GND
GND 5 4 5 7 GND
TxD 3 3 6 2 TxD
DTR 4 2 7 20 DTR
RTS 7 1 8 4 RTS
1Pin 1 2Pin 8
94971
12
RJ-45 (both ends)
Send documentation comments to mdsfeedback-doc@cisco.com.
E-5
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
MGMT 10/100/1000 Ethernet Port
Table E-6 lists the connector pinouts and signal names for a 10/100/1000BASE-T management port
(MDI) cable.
Note The RJ-45 interface only uses pins 1, 2, 3, and 6.
Figure E-2 shows a schematic of the 10/100/1000BASE-T cable required to connect the management
port to a switch or hub (not provided with the switch).
Figure E-2 Twisted-Pair 10/100/1000BASE-T Cable Schematic
Ta b l e E-6 10/100/1000BASE-T Management Port Cable Pinout (MDI)
Pin Signal
1TD+
2TD-
3RD+
6RD–
4Not used
5Not used
7Not used
8Not used
1 TXD+
2 TXD-
3 RXD+
6 RXD-
1 RXD+
MGMT 10/100 Switch/Hub
2 RXD-
3 TXD+
6 TXD-
4NC
5NC
7NC
8NC
4NC
5NC
7NC
8NC
99343
Send documentation comments to mdsfeedback-doc@cisco.com.
E-6
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
MGMT 10/100 Ethernet Port
MGMT 10/100 Ethernet Port
The MGMT 10/100 Ethernet port is an Ethernet port with an RJ-45 connector. You can use a modular,
RJ-45, straight-through UTP cable to connect the management port to an external hub, switch, or router
(see Figure E-3).
Figure E-3 RJ-45 Interface Cable Connector
Table E-7 lists the connector pinouts and signal names for a 10/100BASE-T management port (MDI)
cable.
Note The RJ-45 interface only uses pins 1, 2, 3, and 6.
1Pin 1 2Pin 8
94971
12
RJ-45 (both ends)
Ta b l e E-7 10/100BASE-T Management Port Cable Pinout (MDI)
Pin Signal
1TD+
2TD-
3RD+
6RD–
4Not used
5Not used
7Not used
8Not used
Send documentation comments to mdsfeedback-doc@cisco.com.
E-7
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
Supported Power Cords and Plugs
Figure E-4 shows a schematic of the 10/100BASE-T cable required to connect the management port to
a switch or hub (not provided with the switch).
Figure E-4 Twisted-Pair 10/100BASE-T Cable Schematic
Supported Power Cords and Plugs
Each power supply has a separate power cord. Standard power cords or jumper power cords are available
for connection to a power distribution unit having IEC 60320 C19 outlet receptacles. The jumper power
cords, for use in cabinets, are available as an optional alternative to the standard power cords.
Power Cords
The standard power cords have an IEC C19 connector on the end that plugs into the switch. The optional
jumper power cords have an IEC C19 connector on the end that plugs into the switch, and an IEC C20
connector on the end that plugs into an IEC C19 outlet receptacle.
Note Only the regular power cords or jumper power cords provided with the switch are supported.
Table E-8 lists the power cords for the Cisco MDS 9500 Series switches and provides their lengths in
feet and meters.
1 TXD+
2 TXD-
3 RXD+
6 RXD-
1 RXD+
MGMT 10/100 Switch/Hub
2 RXD-
3 TXD+
6 TXD-
4NC
5NC
7NC
8NC
4NC
5NC
7NC
8NC
99343
Ta b l e E-8 Power Cords for the MDS 9500 Series Switches
Description
Length
Feet Meters
MDS 9513 and MDS 9509 - 3000W Power Supply
Power Cord, 125VAC 20A NEMA 5-20 Plug,
North America/Japan
14 4.27
Power Cord, 250VAC 16A US/Japan, Src Plug NEMA
6-20
13.16 4
Power Cord, 250VAC 16A US/Japan, Src Plug NEMA
L6-20
13.58 4.14
Send documentation comments to mdsfeedback-doc@cisco.com.
E-8
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
Supported Power Cords and Plugs
Power Cord, 250VAC 16A Europe, Src Plug CEE 7/7 13.65 4
Power Cord, 250VAC 16A International, Src Plug IEC 309 13.58 4.14
Power Cord, 250VAC 16A Switzerland, Src Plug SEV 5934-2
Type 23
82.5
Power Cord, 250VAC 16A South Africa, Src Plug EL208,
SABS 164-1
14 4.27
Power Cord, 250VAC 16A Israel, Src Plug SI16S3 14 4.27
Power Cord, 250VAC 16A China, Src Plug GB16C 14 4.27
Power Cord, 250VAC 16A Australia, Src Plug AU20S3 14.76 4.5
Power Cord, 250VAC 16A Korea, Src Plug CEE (7) VII 14.83 4.5
Cabinet Jumper Power Cord, 250VAC 16A, C20-C19
Connectors
92.74
MDS 9509 - 2500W Power Supply
Power Cord, 250VAC 20A NEMA, 6-20 Plug, USA 13.12 4
Power Cord, 250VAC 20A NEMA L6-20 Twist Lock Plug,
USA
13.58 4.14
Power Cord, 250VAC 16A CEE 7/7 Plug, EU 13.12 4
Power Cord, 250VAC 16A IEC 309 Plug, International 13.58 4.14
Power Cord, 250VAC 16A SEV 1011 Plug, Switzerland 82.44
Power Cord, 250VAC SABS 1661 Plug, South Africa 14 4.27
Power Cord, 250VAC 16A SI16S3 Plug, Israel 14 4.27
Cabinet Jumper Power Cord, 250VAC 16A, C20-C19
Connectors
92.74
MDS 9506
Power Cord, 250VAC 20A NEMA 6-20 Plug, US 13.94 4.25
Power Cord, 250VAC 20A NEMA L6-20 Twist Lock Plug, US 13.94 4.25
Power Cord, 250VAC 16A CEE 7/7 Plug, EU 13.94 4.25
Power Cord, 250VAC16A IEC 309 Plug, INTL 13.94 4.25
Power Cord, 250VAC SEV 1011 Plug, SWITZ 13.94 4.25
Power Cord, 250VAC SABS 1661 Plug, South Africa 13.94 4.25
Power Cord, 250VAC 16A SI16S3 Plug, Israel 13.94 4.25
Power Cord, 250VAC 13A BS1363 Plug (13A fuse), UK 13.94 4.25
Power Cord, 250VAC 10A GB1002 Plug, China 13.94 4.25
Power Cord, 250VAC 13A KSC8305 Plug, Korea 13.94 4.25
Power Cord, 250VAC 15A CNS10917-2 Plug, Taiwan 13.94 4.25
Cabinet Jumper Power Cord, 250VAC 16A C20-C19
Connectors
92.74
Table E-8 Power Cords for the MDS 9500 Series Switches (continued)
Description
Length
Feet Meters
Send documentation comments to mdsfeedback-doc@cisco.com.
E-9
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
Supported Power Cords and Plugs
Supported Plugs for 6000-W AC, 2500-W AC, and 1900-W AC Power Supplies
Figure E-5 shows the supported plugs for the 6000-W AC, 3000-W AC, 2500-W AC, and 1900-W AC
power supplies.
Figure E-5 6000-W AC, 3000-W AC, 2500-W AC, and 1900-W AC Power Supply Plugs
1International
(6000 W, 3000 W, 2500 W, and 1900 W)
IEC 309 (20 A)
4North America (locking)
(6000 W, 3000 W, 2500 W, and 1900 W)
NEMA L6-20 plug (2 0A)
2Europe
(6000 W, 3000 W, 2500 W, and 1900 W)
CEE 7/7 (16 A)
5Switzerland
(6000 W, 3000 W, 2500 W, and 1900 W)
23 G SEV 1011 (16 A)
3North America (non-locking)
(6000 W, 3000 W, 2500 W, and 1900 W)
NEMA 6-20 plug (20 A)
6South Africa
(6000 W, 3000 W, 2500 W, and 1900 W)
EL 208, SABS 164-1 (16 A)
94973
12
4 5
3
6
Send documentation comments to mdsfeedback-doc@cisco.com.
E-10
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
Supported Power Cords and Plugs
Figure E-6 shows an additional plug that is supported for the 1900-W AC power supply only.
Figure E-6 Additional Power Supply Plug Supported for 1900-W Only
Figure E-7 shows an additional plug that is supported for the 3000-W and 2500-W power supply, using
110 VAC.
Note Using the plug in Figure E-7 at 110 VAC results in 1300 W available to the system.
Figure E-7 Additional Power Supply Plug Supported for 3000-W and 2500-W 110 VAC Only
1United Kingdom
BS89/13, BS 1363/A
(13 A; replaceable fuse)
113147
1NEMA 5-20P
North American power cord product ID: CAB-7513AC
110 VAC (20 A)
113168
Send documentation comments to mdsfeedback-doc@cisco.com.
E-11
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
Supported Power Cords and Plugs
Supported Plugs for the 4000-W AC Power Supply
Figure E-8 shows the supported plugs for the 4000-W AC power supply. The power cable on the 4000
W power supply is nondetachable.
Figure E-8 4000-W Power Supply Plugs
Jumper Power Cord
Figure E-9 shows the C19 and C20 connectors on the optional jumper power cord for the Cisco MDS
9500 Series. The C19 connector plugs into the C20 inlet on the Cisco MDS 9500 Series power supply,
while the C20 connector plugs into the C19 receptacle of a power distribution unit for a cabinet.
Figure E-9 End of C19 and C20 Connectors on Jumper Power Cord for Cisco MDS 9500 Series
1International
(4000-W power supply)
IEC 60309 (3 0A, 250 V)
2North America (Locking)
(4000-W power supply)
NEMA L6-30 plug (30 A, 250 V)
94974
12
1C19 and C20 connectors on jumper power cord for Cisco 9500 Series
Power cord product ID:CAB-C19-CBN
250 VAC 16 A, C20-C19 connectors
113148
C20
C19
Send documentation comments to mdsfeedback-doc@cisco.com.
E-12
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
Supported Power Cords and Plugs
Power Supply AC Power Cords
Table E-9 lists the specifications for the 6000 W AC power cords that are available for the AC-input
power supply. Included in the table are references to illustrations of the power cords.
Ta b l e E-9 Power Supply AC Power Cords
Locale
Power Cord
Part Number Source Plug Type Cordset Rating
Power Cord
Reference
Illustration
North
America/Japan
CAB-9K2A-NA NEMA 5-20 20 A, 125 VAC Figure E-10
US/Japan CAB-9K16A-US2 NMEA L6-20 16 A, 250 VAC Figure E-11
Australia CAB-9K16A-AUS AU20S3 16 A, 250 VAC Figure E-12
China CAB-9k16A-CH GB16C 16 A, 250 VAC Figure E-13
Switzerland CAB-9K16A-SW SEV 5934 16 A 250 VAC Figure E-14
Continental
Europe
CAB-9K16A-EU CEE7/7 16 A 250 VAC Figure E-15
Cabinet Jumper
Power Cord
CAB-C19-CBN C 20-C19 16 A 250 VAC Figure E-16
Send documentation comments to mdsfeedback-doc@cisco.com.
E-13
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
Supported Power Cords and Plugs
AC Power Cord Illustrations
This section contains the AC power cord illustrations. An AC power cord can be used with several power
supplies. See the power supply specifications tables for the correct AC power cord illustrations for your
power supply.
Figure E-10 CAB-9K20A-NA
Figure E-11 CAB-9K16A-US2
Cordset rating: 20 A, 125 V
Length: 14 ft 0 in. (4.26 m)
113356
Connector: IEC 60320 C19
Plug: NEMA 5-20
Cordset rating: 16 A, 250 V
Length: 14 ft 0 in. (4.26 m)
113363
Connector: IEC 60320 C19
Plug: NEMA L6-20
Send documentation comments to mdsfeedback-doc@cisco.com.
E-14
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
Supported Power Cords and Plugs
Figure E-12 CAB-9K16A-AUS
Figure E-13 CAB-9K16A-CH
Figure E-14 CAB-9K16A-SW
Cordset rating: 16 A, 250 V
Length: 14 ft 0 in. (4.26 m)
140586
Connector: IEC 60320 C19
Plug: AU20S3
Connector: IEC 60320-1 C19
Plug: GB16C
Cordset rating: 16 A, 250 V
Length: (4270 mm)
185066
Plug: SEV 5934-2
Type 23
Cordset rating: 16 A, 250 V
Length: 8 ft 2 in. (2.5 m)
113364
Connector: IEC 60320 C19
Send documentation comments to mdsfeedback-doc@cisco.com.
E-15
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
Supported Power Cords and Plugs
Figure E-15 CAB-9K16A-EU
Figure E-16 CAB-C19-CBN
Connector: IEC 60320 C15
Cordset rating: 16 A, 250 V
Length: 8 ft 2 in. (2.5 m)
Plug: CEE 7/7
113348
Connector: IEC 60320 C19
Plug: IEC 60320 C20
240902
Send documentation comments to mdsfeedback-doc@cisco.com.
E-16
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix E Cable and Port Specifications
Supported Power Cords and Plugs
Send documentation comments to mdsfeedback-doc@cisco.com.
F-1
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
APPENDIX
F
Site Planning and Maintenance Records
This appendix provides a Site Planning list and includes the following records to use when installing the
Cisco MDS 9500 Series:
Contacting Customer Service, page F-1
Site Preparation Checklist, page F-4
Contact and Site Information, page F-6
Chassis and Module Information, page F-7
Note For information on how to query the switch for configuration information, see Cisco MDS 9000 Family
CLI Configuration Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide.
Contacting Customer Service
If you are unable to solve a startup problem after using the troubleshooting suggestions in this appendix,
contact your customer service representative for assistance and further instructions. Before you call,
have the following information ready to help your service provider assist you as quickly as possible:
Date you received the switch.
Chassis serial number. See the “Finding the Chassis Serial Number” section on page F-2.
Type of software and release number.
Maintenance agreement or warranty information.
Brief description of the problem.
Brief explanation of the steps you have already taken to isolate and resolve the problem.
Note If you purchased Cisco support through a Cisco reseller, contact the reseller directly. If you
purchased support directly from Cisco, contact Cisco Technical Support at this URL:
http://www.cisco.com/warp/public/687/Directory/DirTAC.shtm
Send documentation comments to mdsfeedback-doc@cisco.com.
F-2
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix F Site Planning and Maintenance Records
Contacting Customer Service
Finding the Chassis Serial Number
Tip If you have CLI access, run the show sprom backplane 1 command to display the backplane
contents, including the switch serial number.
Figure F-1 shows the location of the serial number label on the Cisco MDS 9513 Director.
Figure F-1 Serial Number Location on Cisco MDS 9513 Director
In later releases of the Cisco MDS 9509 Director, the chassis serial number label was moved, as shown
in Figure F-2. Earlier releases may have the serial number label on the right side instead of the left.
144956, 781-00448-01
Cisco 11 character label
SN: XXXNNNNXXXX
Send documentation comments to mdsfeedback-doc@cisco.com.
F-3
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix F Site Planning and Maintenance Records
Contacting Customer Service
Figure F-2 Serial Number Location on Cisco MDS 9509 Director
The Cisco MDS 9506 Director chassis serial number label is shown in Figure F-3.
Figure F-3 Serial Number Location on Cisco MDS 9506 Director
113305
SN: AAANNNNXXXX
113872, 781-00275-01A0
SN: AAANNNNXXXX
Send documentation comments to mdsfeedback-doc@cisco.com.
F-4
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix F Site Planning and Maintenance Records
Site Preparation Checklist
Site Preparation Checklist
Planning the location and layout of your equipment rack or wiring closet is essential for successful
switch operation, ventilation, and accessibility. Table F-1 lists the site planning tasks that Cisco
recommends completing before installing the Cisco MDS 9500 Series.
Consider heat dissipation when sizing the air-conditioning requirements for an installation. See
Table D-1 on page D-1 for the environmental requirements. See the“Power Specifications for the Cisco
MDS 9513 Director” section on page D-6, the “Power Specifications for the Cisco MDS 9509 Director”
section on page D-9, and the “Power Specifications for the Cisco MDS 9506 Director” section on
page D-14 for power and heat ratings.
Ta b l e F-1 Site Planning Checklist
Task No. Planning Activity Verified By Time Date
1Space evaluation:
Space and layout
Floor covering
Impact and vibration
Lighting
Maintenance access
2Environmental evaluation:
Ambient temperature
Humidity
Altitude
Atmospheric
contamination
Air flow
3Power evaluation:
Input power type
Power receptacles (20 A)1
Receptacle proximity to
the equipment
Dedicated (separate)
circuits for redundant
power supplies
UPS2 for power failures
DC systems: proper gauge
wire and lugs
4Grounding evaluation:
Circuit breaker size
CO ground (AC- and
DC-powered systems)
Send documentation comments to mdsfeedback-doc@cisco.com.
F-5
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix F Site Planning and Maintenance Records
Site Preparation Checklist
5Cable and interface equipment
evaluation:
Cable type
Connector type
Cable distance limitations
Interface equipment
(transceivers)
6EMI3 evaluation:
Distance limitations for
signaling
Site wiring
RFI4 levels
1. Verify that each power supply installed in the chassis has a dedicated AC source or DC source circuit.
2. UPS = uninterruptible power supply
3. EMI = electromagnetic interference
4. RFI = radio frequency interference
Table F-1 Site Planning Checklist (continued)
Task No. Planning Activity Verified By Time Date
Send documentation comments to mdsfeedback-doc@cisco.com.
F-6
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix F Site Planning and Maintenance Records
Contact and Site Information
Contact and Site Information
Use the following worksheet (Figure F-3) to record contact and site information.
Ta b l e F-2 Contact and Site Information
Contact person
Contact phone
Contact e-mail
Building/site name
Data center location
Floor location
Address (line 1)
Address (line 2)
City
State
Zip code
Country
Send documentation comments to mdsfeedback-doc@cisco.com.
F-7
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix F Site Planning and Maintenance Records
Chassis and Module Information
Chassis and Module Information
Use the following worksheets (Table F-3 and Table F-4) to record information about the chassis and
modules.
Contract number_______________________________________________
Chassis serial number___________________________________________
Product number________________________________________________
Ta b l e F-3 Network-Related Information
Switch IP address
Switch IP netmask
Host name
Domain name
IP broadcast address
Gateway/router address
DNS address
Modem telephone number
Ta b l e F-4 Module Information
Slot Module Type Module Serial Number Notes
1
2
3
4
5
Supervisor
Send documentation comments to mdsfeedback-doc@cisco.com.
F-8
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix F Site Planning and Maintenance Records
Chassis and Module Information
Note Slots 7, 8, and 9 are only available in the Cisco MDS 9509 Director.
6
Supervisor
7
8
9
Table F-4 Module Information (continued)
Slot Module Type Module Serial Number Notes
Send documentation comments to mdsfeedback-doc@cisco.com.
IN-1
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
INDEX
Numerics
12-port 4-Gbps Fibre Channel switching modules
description 1-35
figure 1-35
14/2-port Multiprotocol Services module. See MPS-14/2
16-port switching modules
description 1-38
figure 1-38
LEDs (table) 1-37, 1-40
24-port 4-Gbps Fibre Channel switching modules
description 1-35
figure 1-35
24-port 8-Gbps Fibre Channel switching modules
description 1-33
figure 1-33
32-port Fibre Channel Advanced Services Module. See
ASM
32-port Fibre Channel Storage Services Module. See SSM
32-port switching modules
description 1-37
figure 1-38
LEDs (table) 1-37, 1-40
4/44-port 8-Gbps Host-Optimized Fibre Channel switching
modules
description 1-33
figure 1-33
48-port 4-Gbps Fibre Channel switching modules
connectors 1-33, 1-34
description 1-34
figure 1-33, 1-34
LEDs (figure) 1-34
48-port 8-Gbps Fibre Channel switching modules
description 1-33
figure 1-33
4-port 10-Gbps Fibre Channel switching modules
description 1-36
figure 1-36
A
AC power
installing (MDS 9509 Director) 2-57
providing (MDS 9506 Director) 2-30, 2-32
providing (MDS 9509 Director) 2-30, 2-32
providing (MDS 9513 Director) 2-29
removing (MDS 9509 Director) 2-56
removing (MDS 9513 Director) 2-52
airflow specifications D-4
ASM
description 1-48
figure 1-48
LEDs (table) 1-49
audience
description 1-xv
B
backplane
description 1-8
batteries on CSM 2-50
binary images
downloading 1-48, 1-50
Bladeswitch 1-9
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-2
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
C
cabinet installation guidelines 2-2
cabinets
perforated, requirements C-3
requirements C-1
See also racks
solid wall requirements C-4
space requirements C-2
cabling
COM1 port E-3
console port E-2
MGMT 10/100/1000 Ethernet port E-4
MGMT 10/100 Ethernet port E-6
requirements B-2
SFP transceivers B-14, B-15
Caching Services Module. See CSM
chassis
grounding 2-23
installing guidelines 2-3
unpacking 2-5
chassis (MDS 9506 Director)
description 1-7
features 1-7
figure 1-7
grounding (figure) 2-27
installing in a rack (procedure) 2-15
preinstallation 2-2
serial number location F-3
chassis (MDS 9509 Director)
description 1-6
features 1-6
figure 1-6
grounding 2-26
installing in a rack (procedure) 2-11
power supplies 2-11
preinstallation 2-2
serial number location F-2
chassis (MDS 9513 Director)
description 1-3
features 1-3
figure 1-4, 1-5
installing in a rack (procedure) 2-7
power supplies 1-10, 2-7, 2-28
preinstallation 2-2
serial number location F-2
Cisco MDS 9500 Series Multilayer Directors
description 1-1
Cisco MDS Fabric Switch 1-9
clock modules
description 1-8, 2-76
installing (MDS 9506 Director) 2-86
installing (MDS 9509 Director) 2-83
installing (MDS 9513 Director) 2-79
installing in MDS 9506 Director (procedure) 2-86
installing in MDS 9509 Director (procedure) 2-79,
2-83
removing (MDS 9506 Director) 2-84
removing (MDS 9509 Director) 2-80
removing (MDS 9513 Director) 2-76, 2-77
removing from MDS 9506 Director (procedure) 2-83
removing from MDS 9509 Director (procedure) 2-77,
2-80
COM1 port
cabling E-3
connecting B-4
pinouts (table) E-3
support B-4
support (note) B-4
CompactFlash cards
installing 2-76
LED on supervisor module 1-23
removing 2-75
Supervisor-1 modules 1-23
Supervisor-2 modules 1-19
Supervisor-2 modules, LEDs 1-19
connecting
COM1 port B-4
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-3
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
console port B-2
Fibre Channel ports B-9
MGMT 10/100/1000 B-6
MGMT 10/100 Ethernet port B-7
console port
cabling E-2
connecting B-2
pinouts E-2
contact and site information F-6
crossbar fan modules
description 1-16
crossbar modules
Cisco MDS 9513 support 1-25
description 1-25
installing 2-48
location 1-25
removing 2-47, A-5
supervisor association 1-25
crossbar switching fabric
description 1-22
dual fabric configurations 1-17, 1-22
mesh design 1-17
Supervisor-2 modules 1-17
CSM
batteries 2-50
description 1-52
installing 2-45
internal (figure) 1-53
LEDs (table) 1-54
maintaining 2-50
powering off 2-44
removing 2-44
requirement (note) 2-44
CUP 1-41
customer service, contacting F-1
CWDM transceivers
description 1-56
SFP transceiver specifications D-30
D
DC power
installing (MDS 9509 Director) 2-62
providing (MDS 9506 Director) 2-34
providing (MDS 9509 Director) 2-33
removing (MDS 9509 Director) 2-61
documentation
additional publications 1-xviii
downloading software images
ASM-SFN image 1-48
SSM image 1-50
DWDM transceivers
description 1-57, D-34
E
electrostatic discharge (ESD) 2-19
environmental specifications D-1
Ethernet port
MGMT 10/100 B-7
MGMT 10/100/1000 B-6
F
fan modules
crossbar fan modules, description 1-16
description 1-16
failure (caution) 1-16
LEDs 1-16
removing and installing 2-68
Fiber Connectivity 1-41
fiber optic cables, maintaining B-16
Fibre Channel/Gigabit Ethernet SFP transceivers 1-56
Fibre Channel ports
connecting B-9
connecting with LC-type cables (figure) B-15
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-4
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
G
Genaration 3 Modules
Installing the MDS 9000 4/44-Port 8-Gbps
Host-Optimized Module A-3
Generation 1 modules
services modules 1-41
switching modules 1-32
Generation 2 modules
switching modules 1-32
Generation 3 modules
switching modules 1-32
Gigabit Ethernet/Fibre Channel SFP transceiver
specifications D-28
grounding
attaching the ESD wrist strap 2-19
best practices 2-17
chasis 2-23
establishing the system ground 2-22
required tools and equipment 2-22
H
hardware compatibility matrix (table) 1-27
heat dissipation
Cisco MDS 9506 Director D-16
Cisco MDS 9509 Director D-7, D-11
high availability
features 1-1
I
IBM BladeCenter 1-9
installing
chassis (MDS 9506 Director) 2-2
chassis (MDS 9509 Director) 2-2
chassis (MDS 9513 Director) 2-2
CompactFlash cards 2-76
crossbar modules 2-48
EIA shelf brackets C-6
equipment required 2-5
guidelines 2-3
power supplies (Cisco MDS 9513 Director 2-54
power supplies (MDS 9509 Director) 2-57, 2-62
rack mount brackets C-11
rack-mounting guidelines C-7
services modules 2-38
SFP transceiver cables B-15
SFP transceivers (note) B-13
shelf brackets C-12
supervisor modules 2-38, 2-40
switching modules 2-38
Telco shelf brackets C-6
X2 transceivers B-11
installing SFP transceivers B-14
IPS modules
IPS-4 modules (figure) 1-47
IPS-4 modules, description 1-46
IPS-8 modules, description 1-46
IPS-8 modules, figure 1-46
LEDs (table) 1-47
IP Storage Services module. See IPS modules
IPv6 1-41
L
LC-type cables
connecting to Fibre Channel ports B-15
figure B-15
LEDs
ASM (table) 1-49
clock modules 1-8, 1-16
CSM (table) 1-54
fan modules 1-16
IPS modules (table) 1-47
MDS 9513 Director power supplies (table) 1-11
MPS-14/2 (table) 1-43, 1-45
Supervisor-2 modules (table) 1-20
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-5
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
switching modules (table) 1-37, 1-40
M
maintaining
CSM 2-50
CSM disk drives 2-51
fiber optic cables B-16
SFP transceivers B-16
maintenance records F-1
MDS 9506 Director
description 1-7
grounding location (figure) 2-27
heat dissipation D-16
installing clock modules (procedure) 2-86
installing in a rack(procedure) 2-15
power supply LEDs (table) 1-8, 1-15
removing clock modules (procedure) 2-83
MDS 9509 Director
description 1-6
figure 1-6
grounding location (figure) 2-26
heat dissipation D-7, D-11
installing clock modules (procedure) 2-79, 2-83
installing in a rack (procedure) 2-11
power supply LEDs (table) 1-8, 1-15
removing clock modules (procedure) 2-77, 2-80
MDS 9513 Director
installing in a rack (procedure) 2-7
MGMT 10/100/1000 Ethernet port
cabling E-4
pinouts E-4
MGMT 10/100/1000 port
connecting B-6
MGMT 10/100 Ethernet port
cabling E-6
connecting B-7
pinouts E-6
Migration Procedures
Generation 3 modules A-3
Installing MDS 9513 Fabric 2 Modules and Installing
MDS 9000 24-port or 48-port 8-Gbps Modules A-9
Installing MDS 9513 Fabric 2 Modules and Running
Cisco SAN-OS 3.x A-5
Installing the MDS 9000 4/44-Port 8-Gbps
Host-Optimized Module A-3
Installing the MDS 9513 Fabric 2 Modules and
Activating Higher Bandwidth by Reloading the
Switch A-10
Migration Procedure for the MDS 9509 Director and
MDS 9506 Director A-12
modules
chassis compatibility 1-27
specifications D-4
weight D-5
MPS-14/2
description
LEDs (table) 1-43, 1-45
software release requirements 1-44, 1-48
N
NEBS 2-19
network connections, preparing B-2
new and changed information (table) 1-ix
O
open racks, standard (requirements) C-5
organization
description 1-xv
P
PEMs
installing 2-64
removing 2-64
physical specifications (table) D-2
pinouts
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-6
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
COM 1 port E-3
console port E-2
MGMT 10/100/1000 Ethernet port E-4
MGMT 10/100 Ethernet port E-6
plugs supported for power supplies E-7
port
MGMT 10/100/1000 B-6
on supervisor module 1-22
port indexes
availability 1-28
description 1-28
Generation 1 limitations 1-28
Generation 2 maximum 1-31
Generation combination (example) 1-30
Generation combination limitations 1-30
port interfaces
Supervisor-2 modules 1-18
power cord, jumper E-11
power cords, length E-7
powering up the switch 2-36
power supplies
chassis (MDS 9509 Director) 2-11
chassis (MDS 9513 Director) 2-7, 2-28
circuits 2-4
description 1-9
installing (Cisco MDS 9506 Director) 2-67
installing (Cisco MDS 9513 Director) 2-54
installing (MDS 9509 Director) 2-57, 2-62
LEDs 1-11
LEDs (table) 1-11
MDS 9506 Director LEDs (table) 1-8, 1-15
MDS 9509 Director LEDs (table) 1-8, 1-15
MDS 9513 Director 1-10
MDS 9513 Director (figure) 1-10
removing (Cisco MDS 9506 Director) 2-67
removing (MDS 9509 Director) 2-56, 2-61
removing (MDS 9513 Director) 2-52
starting up the switch 2-28
supported plugs E-7
power supplies (Cisco MDS 9506 Director)
removing and installing PEMs 2-64
specifications D-14
power supplies (Cisco MDS 9509 Director)
specifications D-6, D-9
power supplies (MDS 9506 Director)
description 1-15
power supplies (MDS 9509 Director)
description 1-12
pre-installation
guidelines 2-2
rack mount brackets C-7
R
rack-mount installation options 2-2
racks
EIA installing C-10
open, requirements C-5
required equipment C-8
requirements C-1
See also cabinets.
space requirements C-2
Telco installing C-9
Telco requirements C-6
records
chassis and module information F-7
contact and site information F-6
site planning and maintenance F-1
removing
CompactFlash cards 2-75
crossbar modules 2-47, A-5
CSM 2-44
power supplies (MDS 9509 Director) 2-56, 2-61
power supplies (MDS 9513 Director) 2-52
services modules 2-45
SFP transceiver cables B-14
SFP transceivers B-12
shelf brackets C-12
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-7
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
supervisor modules 2-39
switching modules 2-45
X2 transceivers B-11
S
SAN extension 1-41
serial number
location (MDS 9506 Director) F-3
location (MDS 9509 Director) F-2
location (MDS 9513 Director) figure F-2
services modules
ASM 1-48
CSM 1-52
description 1-41
Generation 1 modules 1-41
installing 2-38, 2-45
IPS modules 1-46
MPS-14/2 module 1-44
MSFM-18/4 module 1-42
MSM-18/4 module 1-41
removing 2-45
specifications D-4
SSM 1-50
SFP and SFP+ transceivers
specifications D-22
SFP transceivers
cabling B-14, B-15
CWDM 1-56, D-30
description 1-56, B-12, D-22
DWDM 1-57, D-34
Fibre Channel 1-56
Fibre Channel/Gigabit Ethernet 1-56
Fibre Channel/Gigabit Ethernet supported D-28
Fibre Channel specifications D-23
Fibre Channel supported D-23
Gigabit Ethernet 1-56
installing B-14
latches supported B-12
removing B-12
shelf bracket
Cisco MDS 9500, installation C-13
installing Telco/EIA C-6
shelf brackets
description C-13
site planning preparation checklist F-4
specifications
airflow D-4
cables E-1
environmental D-1
heat dissipation for Cisco MDS 9506 Director D-16
heat dissipation for Cisco MDS 9509 Director D-7,
D-11
MDS 9513 Director D-6
modules D-4
physical (MDS 9506 Director) D-3
pinouts E-1
power, MDS 9506 Director D-14
power, MDS 9509 Director D-6, D-9
SFP and SFP+ transceivers D-22
SSM
alarm LEDs 1-50
description 1-50
figure 1-50
LEDs (table) 1-51
power-on LEDs 1-50
ready LEDs 1-50
self-test passed LEDs 1-50
self-test running LEDs 1-50
Supervisor-1 modules
CompactFlash cards 1-23
control and management 1-21
Ethernet port B-7
features 1-21
figure 1-21
LEDs 1-23
LEDs (figure) 1-23
LEDs (table) 1-23
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-8
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
memory options 1-22
nondisruptive restart 1-21
processor 1-22
redundant central arbiter 1-21
support (note) 1-21
warm switchover 1-22
Supervisor-2
Ethernet port B-6
Supervisor-2 modules
CompactFlash cards 1-19
CompactFlash cards LEDs 1-19
control and management 1-18
description 1-17
features 1-17
figure 1-17
integrated crossbar switching fabric 1-17
LEDs 1-19
LEDs (figure) 1-19
LEDs (table) 1-20
LEDs description 1-19
memory options 1-18
nondisruptive restart 1-18
port interfaces 1-18
processor 1-18
redundant central arbiter 1-18
warm switchover 1-18
supervisor module
port interfaces 1-22
supervisor modules
description 1-16
installing 2-38, 2-40
removing 2-39
specifications D-4
switching modules
12-port 4-Gbps Fibre Channel switching
modules 1-35
16-port 2-Gbps Fibre Channel (figure) 1-38
24-port 4-Gbps Fibre Channel switching
modules 1-35
24-port 8-Gbps Fibre Channel switching
modules 1-33
32-port 2-Gbps Fibre Channel (figure) 1-37
4/44-port 4-Gbps Host-Optimized Fibre Channel
switching modules 1-33
48-port 4-Gbps Fibre Channel switching
modules 1-34
48-port 8-Gbps Fibre Channel switching
modules 1-33
4-port 10-Gbps Fibre Channel switching
modules 1-36
description 1-32
downloading binary image 1-48, 1-50
features 1-39
Generation 1 modules 1-32
Generation 2 modules 1-32
Generation 3 modules 1-32
installing 2-38, 2-45
LEDs (table) 1-37, 1-40
removing 2-45
specifications D-4
system grounding 2-17
T
Telco racks (requirements) C-6
transceivers
description 1-55
supported SFP transceivers 1-55
supported X2 transceiver 1-55
troubleshooting
contacting customer service F-1
W
weight of modules D-5
X
X2 transceivers
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-9
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
description 1-55, D-19
installing B-11
removing B-11
supported (table) D-20
Numerics
12-port 4-Gbps Fibre Channel switching modules
description 36
figure 37
14/2-port Multiprotocol Services module. See
MPS-14/2
16-port switching modules
description 39
figure 39
LEDs (table) 38, 41
24-port 4-Gbps Fibre Channel switching modules
description 36
figure 36
24-port 8-Gbps Fibre Channel switching modules
description 34
figure 34
32-port Fibre Channel Advanced Services Module.
See ASM
32-port Fibre Channel Storage Services Module.
See SSM
32-port switching modules
description 38
figure 39
LEDs (table) 38, 41
4/44-port 8-Gbps Host-Optimized Fibre Channel
switching modules
description 35
figure 35
48-port 4-Gbps Fibre Channel switching modules
connectors 34, 35
description 35
figure 34, 35
LEDs (figure) 35
48-port 8-Gbps Fibre Channel switching modules
description 34
figure 34
4-port 10-Gbps Fibre Channel switching modules
description 37
figure 37
A
AC power
installing (MDS 9509 Director) 57
providing (MDS 9506 Director) 30, 32
providing (MDS 9509 Director) 30, 32
providing (MDS 9513 Director) 29
removing (MDS 9509 Director) 56
removing (MDS 9513 Director) 52
airflow specifications 4
ASM
description 49
figure 49
LEDs (table) 50
audience
description xv
B
backplane
description 8
batteries on CSM 50
binary images
downloading 49, 51
Bladeswitch 9
C
cabinet installation guidelines 2
cabinets
perforated, requirements 3
requirements 1
See also racks
solid wall requirements 4
space requirements 2
cabling
COM1 port 3
console port 2
MGMT 10/100 Ethernet port 6
MGMT 10/100/1000 Ethernet port 4
requirements 2
SFP transceivers 14, 15
Caching Services Module. See CSM
chassis
grounding 23
installing guidelines 3
unpacking 5
chassis (MDS 9506 Director)
description 7
features 7
figure 7
grounding (figure) 27
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-10
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
installing in a rack (procedure) 15
preinstallation 2
serial number location 3
chassis (MDS 9509 Director)
description 6
features 6
figure 6
grounding 26
installing in a rack (procedure) 11
power supplies 11
preinstallation 2
serial number location 2
chassis (MDS 9513 Director)
description 3
features 3
figure 4, 5
installing in a rack (procedure) 7
power supplies 10, 7, 28
preinstallation 2
serial number location 2
Cisco MDS 9500 Series Multilayer Directors
description 1
Cisco MDS Fabric Switch 9
clock modules
description 8, 76
installing (MDS 9506 Director) 86
installing (MDS 9509 Director) 83
installing (MDS 9513 Director) 79
installing in MDS 9506 Director (procedure) 86
installing in MDS 9509 Director (procedure)
79, 83
removing (MDS 9506 Director) 84
removing (MDS 9509 Director) 80
removing (MDS 9513 Director) 76, 77
removing from MDS 9506 Director (procedure)
83
removing from MDS 9509 Director (procedure)
77, 80
COM1 port
cabling 3
connecting 4
pinouts (table) 3
support 4
support (note) 4
CompactFlash cards
installing 76
LED on supervisor module 24
removing 75
Supervisor-1 modules 23
Supervisor-2 modules 19
Supervisor-2 modules, LEDs 19
connecting
COM1 port 4
console port 2
Fibre Channel ports 9
MGMT 10/100 Ethernet port 7
MGMT 10/100/1000 6
console port
cabling 2
connecting 2
pinouts 2
contact and site information 6
crossbar fan modules
description 16
crossbar modules
Cisco MDS 9513 support 25
description 25
installing 48
location 25
removing 47, 5
supervisor association 25
crossbar switching fabric
description 22
dual fabric configurations 17, 22
mesh design 17
Supervisor-2 modules 17
CSM
batteries 50
description 53
installing 45
internal (figure) 54
LEDs (table) 55
maintaining 50
powering off 44
removing 44
requirement (note) 44
CUP 42
customer service, contacting 1
CWDM transceivers
description 57
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-11
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
SFP transceiver specifications 28
D
DC power
installing (MDS 9509 Director) 62
providing (MDS 9506 Director) 34
providing (MDS 9509 Director) 33
removing (MDS 9509 Director) 61
documentation
additional publications xviii
downloading software images
ASM-SFN image 49
SSM image 51
E
electrostatic discharge (ESD) 19
environmental specifications 1
Ethernet port
MGMT 10/100 7
MGMT 10/100/1000 6
F
fan modules
crossbar fan modules, description 16
description 16
failure (caution) 16
LEDs 16
removing and installing 68
Fiber Connectivity 42
fiber optic cables, maintaining 16
Fibre Channel ports
connecting 9
connecting with LC-type cables (figure) 15
Fibre Channel/Gigabit Ethernet SFP transceivers
57
G
Genaration 3 Modules
Installing the MDS 9000 4/44-Port 8-Gbps
Host-Optimized Module 3
Generation 1 modules
services modules 42
switching modules 33
Generation 2 modules
switching modules 33
Generation 3 modules
Migration Procedures 3
switching modules 33
Gigabit Ethernet/Fibre Channel SFP transceiver
specifications 26
grounding
attaching the ESD wrist strap 19
best practices 17
chasis 23
establishing the system ground 22
required tools and equipment 22
H
hardware compatibility matrix (table) 27
heat dissipation
Cisco MDS 9506 Director 16
Cisco MDS 9509 Director 7, 11
high availability
features 1
I
IBM BladeCenter 9
installing
chassis (MDS 9506 Director) 2
chassis (MDS 9509 Director) 2
chassis (MDS 9513 Director) 2
CompactFlash cards 76
crossbar modules 48
EIA shelf brackets 5
equipment required 5
guidelines 3
power supplies (Cisco MDS 9513 Director 54
power supplies (MDS 9509 Director) 57, 62
rack mount brackets 10
rack-mounting guidelines 6
services modules 38
SFP transceiver cables 15
SFP transceivers (note) 13
shelf brackets 11
supervisor modules 38, 40
switching modules 38
Telco shelf brackets 5
X2 transceivers 11
installing SFP transceivers 14
IP Storage Services module. See IPS modules
IPS modules
IPS-4 modules (figure) 48
IPS-4 modules, description 47
IPS-8 modules, description 47
IPS-8 modules, figure 47
LEDs (table) 48
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-12
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
IPv6 42
L
LC-type cables
connecting to Fibre Channel ports 15
figure 15
LEDs
ASM (table) 50
clock modules 8, 16
CSM (table) 55
fan modules 16
IPS modules (table) 48
MDS 9513 Director power supplies (table) 11
MPS-14/2 (table) 44, 46
Supervisor-2 modules (table) 20
switching modules (table) 38, 41
M
maintaining
CSM 50
CSM disk drives 51
fiber optic cables 16
SFP transceivers 16
maintenance records 1
MDS 9506 Director
description 7
grounding location (figure) 27
heat dissipation 16
installing clock modules (procedure) 86
installing in a rack(procedure) 15
power supply LEDs (table) 8, 15
removing clock modules (procedure) 83
MDS 9509 Director
description 6
figure 6
grounding location (figure) 26
heat dissipation 7, 11
installing clock modules (procedure) 79, 83
installing in a rack (procedure) 11
power supply LEDs (table) 8, 15
removing clock modules (procedure) 77, 80
MDS 9513 Director
installing in a rack (procedure) 7
MGMT 10/100 Ethernet port
cabling 6
connecting 7
pinouts 6
MGMT 10/100/1000 Ethernet port
cabling 4
pinouts 4
MGMT 10/100/1000 port
connecting 6
Migration Procedures
Generation 3 modules 3
Installing MDS 9513 Fabric 2 Modules and In-
stalling MDS 9000 24-port or 48-port
8-Gbps Modules 9
Installing MDS 9513 Fabric 2 Modules and
Running Cisco SAN-OS 3.x 5
Installing the MDS 9000 4/44-Port 8-Gbps
Host-Optimized Module 3
Installing the MDS 9513 Fabric 2 Modules and
Activating Higher Bandwidth by Re-
loading the Switch 10
Migration Procedure for the MDS 9509 Direc-
tor and MDS 9506 Director 12
modules
chassis compatibility 27
specifications 4
weight 5
MPS-14/2
description
LEDs (table) 44, 46
software release requirements 45, 49
N
NEBS 19
network connections, preparing 2
new and changed information (table) ix
O
open racks, standard (requirements) 4
organization
description xv
P
PEMs
installing 64
removing 64
physical specifications (table) 3
pinouts
COM 1 port 3
console port 2
MGMT 10/100 Ethernet port 6
MGMT 10/100/1000 Ethernet port 4
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-13
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
plugs supported for power supplies 7
port
MGMT 10/100/1000 6
on supervisor module 22
port indexes
availability 28
description 28
Generation 1 limitations 28
Generation 2 maximum 32
Generation combination (example) 31
Generation combination limitations 31
port interfaces
Supervisor-2 modules 18
power cord, jumper 11
power cords, length 7
power supplies
chassis (MDS 9509 Director) 11
chassis (MDS 9513 Director) 7, 28
circuits 4
description 9
installing (Cisco MDS 9506 Director) 67
installing (Cisco MDS 9513 Director) 54
installing (MDS 9509 Director) 57, 62
LEDs 11
LEDs (table) 11
MDS 9506 Director LEDs (table) 8, 15
MDS 9509 Director LEDs (table) 8, 15
MDS 9513 Director 10
MDS 9513 Director (figure) 10
removing (Cisco MDS 9506 Director) 67
removing (MDS 9509 Director) 56, 61
removing (MDS 9513 Director) 52
starting up the switch 28
supported plugs 7
power supplies (Cisco MDS 9506 Director)
removing and installing PEMs 64
specifications 14
power supplies (Cisco MDS 9509 Director)
specifications 6, 9
power supplies (MDS 9506 Director)
description 15
power supplies (MDS 9509 Director)
description 12
powering up the switch 36
pre-installation
guidelines 2
rack mount brackets 7
R
rack-mount installation options 2
racks
EIA installing 9
open, requirements 4
required equipment 7
requirements 1
See also cabinets.
space requirements 2
Telco installing 8
Telco requirements 5
records
chassis and module information 7
contact and site information 6
site planning and maintenance 1
removing
CompactFlash cards 75
crossbar modules 47, 5
CSM 44
power supplies (MDS 9509 Director) 56, 61
power supplies (MDS 9513 Director) 52
services modules 45
SFP transceiver cables 14
SFP transceivers 12
shelf brackets 11
supervisor modules 39
switching modules 45
X2 transceivers 11
S
SAN extension 42
serial number
location (MDS 9506 Director) 3
location (MDS 9509 Director) 2
location (MDS 9513 Director) figure 2
services modules
ASM 49
CSM 53
description 42
Generation 1 modules 42
installing 38, 45
IPS modules 47
MPS-14/2 module 45
MSFM-18/4 module 43
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-14
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
MSM-18/4 module 42
removing 45
specifications 4
SSM 51
SFP transceivers
cabling 14, 15
CWDM 57, 28
description 57, 12, 22
Fibre Channel 57
Fibre Channel specifications 23
Fibre Channel supported 23
Fibre Channel/Gigabit Ethernet 57
Fibre Channel/Gigabit Ethernet supported 26
Gigabit Ethernet 57
installing 14
latches supported 12
removing 12
specifications 22
shelf bracket
Cisco MDS 9500, installation 12
installing Telco/EIA 5
shelf brackets
description 12
site planning preparation checklist 4
specifications
airflow 4
cables 1
environmental 1
heat dissipation for Cisco MDS 9506 Director
16
heat dissipation for Cisco MDS 9509 Director
7, 11
MDS 9513 Director 6
modules 4
physical (MDS 9506 Director) 3
pinouts 1
power, MDS 9506 Director 14
power, MDS 9509 Director 6, 9
SFP transceivers 22
SSM
alarm LEDs 51
description 51
figure 51
LEDs (table) 52
power-on LEDs 51
ready LEDs 51
self-test passed LEDs 51
self-test running LEDs 51
supervisor module
port interfaces 22
supervisor modules
description 16
installing 38, 40
removing 39
specifications 4
Supervisor-1 modules
CompactFlash cards 23
control and management 21
Ethernet port 7
features 21
figure 21
LEDs 24
LEDs (figure) 24
LEDs (table) 24
memory options 22
nondisruptive restart 21
processor 22
redundant central arbiter 21
support (note) 21
warm switchover 22
Supervisor-2
Ethernet port 6
Supervisor-2 modules
CompactFlash cards 19
CompactFlash cards LEDs 19
control and management 18
description 17
features 17
figure 17
integrated crossbar switching fabric 17
LEDs 19
LEDs (figure) 19
LEDs (table) 20
LEDs description 19
memory options 18
nondisruptive restart 18
port interfaces 18
processor 18
redundant central arbiter 18
warm switchover 18
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-15
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
switching modules
12-port 4-Gbps Fibre Channel switching mod-
ules 36
16-port 2-Gbps Fibre Channel (figure) 39
24-port 4-Gbps Fibre Channel switching mod-
ules 36
24-port 8-Gbps Fibre Channel switching mod-
ules 34
32-port 2-Gbps Fibre Channel (figure) 38
4/44-port 4-Gbps Host-Optimized Fibre Chan-
nel switching modules 35
48-port 4-Gbps Fibre Channel switching mod-
ules 35
48-port 8-Gbps Fibre Channel switching mod-
ules 34
4-port 10-Gbps Fibre Channel switching mod-
ules 37
description 33
downloading binary image 49, 51
features 40
Generation 1 modules 33
Generation 2 modules 33
Generation 3 modules 33
installing 38, 45
LEDs (table) 38, 41
removing 45
specifications 4
system grounding 17
T
Telco racks (requirements) 5
transceivers
description 56
supported SFP transceivers 56
supported X2 transceiver 56
troubleshooting
contacting customer service 1
W
weight of modules 5
X
X2 transceivers
description 56, 19
installing 11
removing 11
supported (table) 20
Send documentation comments to mdsfeedback-doc@cisco.com.
Index
IN-16
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02

Navigation menu