PLX-series Low Impedance Amplifiers
PLX2000 (172.214)
PLX2800 (172.216)
PLX3600 (172.218)

User Manual

Features:











High power linear amplifiers
2U rack-mount case
Stable down to 2Ω loads
Independent clipping compressors
Independent dual-level high-pass filters
Stereo, Parallel or Bridge Mono modes
Fully balanced signal path
Dual fan cooling
Soft-start on power up
Multi-level system protection
www.citronic.com

Introduction:
Thank you for choosing this Citronic PLX amplifier. This product has been designed to exacting standards to
provide accurate, immediate high power on demand whilst remaining very lightweight and compact for easy
portability. The class H architecture and innate protection circuitry are designed to provide reliable service for many
years. Please, however, read and follow these instructions to attain the best performance from this amplifier and
avoid mis-use through incorrect operation.
Warning:
To prevent the risk of fire or electric shock, do not expose any of the components to rain or moisture.
If liquids are spilled on the casing, stop using immediately, allow unit to dry out and have checked by qualified
personnel before further use.
Avoid impact, extreme pressure or heavy vibration to the case
No user serviceable parts inside – Do not open the case – refer all servicing to qualified service personnel.
Safety





Check for correct mains voltage and condition of IEC lead before connecting to power outlet.
Ensure speaker leads are good condition with no short connections or damaged plugs
Check impedance of speaker loads do not exceed the minimum stated load for the amplifier
Do not allow any foreign objects to enter the case or through the ventilation grilles.

Placement






Keep out of direct sunlight and away from heat sources.
Keep away from damp or dusty environments.
When rack-mounting, ensure adequate support for the base of the amplifier and firm fixings for the front.
Ensure adequate air-flow and do not cover cooling vents at the front and rear of the amplifier
Ensure adequate access to controls and connections

Cleaning




Use a soft cloth with a neutral detergent to clean the casing as required
Use a vacuum cleaner to clear ventilation grilles of any dust or debris build-ups
Do not use strong solvents for cleaning the unit.

Front Panel

19.
20.
21.
22.
23.
24.
25.

Cooling vent
PROTECT LEDs
CLIP LEDs
SIGNAL LEDs
CH1 Gain control
POWER LEDs

24.
25.
26.
27.
28.

POWER switch
BRIDGE LED
PARALLEL LED
CH2 Gain control
Cooling vent

Rear Panel

12.
13.
14.
15.
16.
17.
18.

Cooling vent
Parallel Signal Outs
Signal Inputs
GROUND LIFT switch
Clipping COMPRESS switch
Input SENSITIVITY switch

18.
19.
20.
21.
22.
23.

PARALLEL/STEREO/BRIDGE mode switch
Speaker outputs OUT 1 & OUT 2
4mm binding post speaker outputs
IEC mains inlet
Mains fuse holder
Cooling vent

Operation
Connect speaker cabinets to channel outputs using good quality leads and ensuring that the combined load on
each channel is no lower than 2Ω
(for speaker loads connected from one to another, 4Ω + 4Ω = 2Ω… or even… 8Ω + 8Ω + 8Ω + 8Ω = 2Ω).
Connect the left and right signal input from mixer or other line level source via the XLR connectors on the rear panel
using good quality XLR leads.
If the signal is to be cascaded onto other amplifiers, connect these via the XLR line parallel signal outputs. These
are simply connected in parallel together with the relative inputs.
Connect the amplifier to the mains outlet, making sure that the IEC lead is in good condition and connected
securely.
For extra protection of speakers and amplifier, the COMPRESS switch may be switched in to help prevent overload.
In some extreme cases, the operation of this compressor/limiter can be obtrusive. In these cases, turn off the
COMPRESS switch and use a dedicated compressor/limiter to control the high dynamics.
Select the SENSITIVITY of the amplifier inputs – 0.7V is standard line level, 1.0V is quieter and 1.4V is quieter still
for higher level input signals, which may otherwise cause the amplifier to overdrive
Select the mode in which the amplifier is to be used…


PARALLEL sums both left and right input signals together and feeds the mono signal to both amplifier
outputs. This is useful when driving sub cabinets (which, in arrays, benefit from working together in mono)
and when each channel is powering speakers in different areas (avoiding one area hearing only left output
and the other only right) An LED (“PARALLEL”) shows when this mode is engaged



STEREO is the normal mode of operation where each input is delivered to each output independently



BRIDGE mode couples both amplifier sections together to deliver the full rated power to a single output.
The minimum impedance is 4Ω in this mode. An LED (“BRIDGE”) shows when this mode is engaged

The GROUND LIFT switch disconnects signal ground (or “earth”) from mains ground. In certain cases, it may help
to alleviate mains hum – otherwise, leave ground connected to mains ground.
With CH1 and CH2 level controls turned fully down, switch on the power to the amplifier. This product has a “softstart” function which makes some checks before engaging power to the amplifiers, which may take a few seconds.

With mixer (or other signal source) levels turned down, gradually increase the amplifier’s CH1 and CH2 gain
controls to the required level (normally full) and then gradually increase the signal level from the mixer until sound
can be heard through the speakers and then up to the required level.
During use, the LED indicators will show yellow to show that the channel is on, green if a signal is present and red if
the output is reaching clip level. If the red CLIP LEDs illuminate more than very briefly, reduce the volume until they
hardly light up at all.
If the internal protection circuitry detects a fault in the speakers or amp, the channel(s) will enter Protect Mode and a
red “PROTECT” LED will illuminate on the front panel to show this. Switch the amplifier off and check the entire
system (including leads) before powering up again. If still in Protect Mode, seek advice from qualified service
personnel.
Before powering down, turn CH1 and CH2 gain controls fully down to avoid loud noises when switching off.

SPECIFICATIONS

Power supply

PLX2000
230Vac 50/60Hz (IEC, 15A max.)

PL2800

Output: RMS @ 2Ω

2 x 1000W

2 x 1400W

2 x 1800W

Output: RMS @ 4Ω

2 x 700W

2 x 1050W

2 x 1350W

Output: RMS @ 8Ω

2 x 400W

2 x 600W

2 x 800W

Bridge power: RMS @ 4Ω

1700W

2300W

2900W

Bridge power: RMS @ 8Ω

1250W

1750W

2300W

Input impedance

20kΩ

Frequency response

5Hz – 50kHz

S/N ratio

>105dB

THD

0.05%

Circuit protection

Short-circuit, DC, Overload, Boot-strap short test

Dimensions

88 x 482 x 453mm

Weight

22.5kg

25.0kg

PL3600

26.0kg

Troubleshooting
No power light on front panel switch
Power light is on but no other LEDs and not
output
Power light and Signal LEDs are lit but no
output

“PM” (Protect Mode) LED is lit and there is no
output

Output is very distorted and “CLIP” LEDs are
lighting

Output is working but at very low level

Ensure IEC is connected to mains and mains lead is in good condition
Ensure mains outlet is switched on
Check input signal and connection leads
Ensure CH1 and CH2 level controls are not turned fully down
Check speaker cabinets are not blown and are in good working order
Check speaker leads are in good condition and connected properly
Switch off and disconnect from mains
Check speakers are in good working order and not shorted out (using a
multi-tester)
After checking all connected items, power up again
If still in Protect Mode, switch off again and refer to qualified service
personnel
Check speaker impedance is not below rated Ohms
Turn down Input level from audio source
Switch SENSITIVITY at rear to a higher voltage
Turn down CH1 and CH2 level controls
Ensure input source is at line level
Increase input level from audio source
Turn up CH1 and CH2 level controls
Switch SENSITIVITY at rear to a lower voltage

Note: for further troubleshooting, refer equipment to qualified service personnel for testing

© Citronic 2011



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 4
Language                        : en-GB
Tagged PDF                      : Yes
Title                           : 
Author                          : Administrator
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2011:08:30 13:25:19
Modify Date                     : 2011:08:30 13:25:19
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools

Navigation menu