Climax Technology Co BXZW Wireless Outdoor Bell Box User Manual BX 32ZW 20160111 statement

Climax Technology Co Ltd Wireless Outdoor Bell Box BX 32ZW 20160111 statement

Users Manual

 1BX-32ZW Outdoor Bellbox  Introduction BX-32ZW is a Z-Wave Outdoor Bellbox. It is capable of raising alarm upon receiving alarm signal from the Z-Wave network when an alarm is activated. During the alarm, the Bellbox will sound alarm with its built-in siren and also flash the strobe light to attract attention. The Bellbox is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Z-Wave is a wireless communication protocol that uses a low-power RF radio. By taking advantage of the Z-Wave mesh network, commands can be transmitted to their destination via intermediary “listening” Z-Wave products.  Parts Identification 1. Tamper Switch The Tamper switch will be activated when the Bellbox is removed from mounted surface, or it cover   opened. 2. Battery Compartment The Bellbox is powered by two 1.5V D-Cell alkaline battery. 3. Battery Switch The battery switch is used when battery is installed in the Outdoor Bellbox. To power on/off the   Outdoor Bellbox, switch the ON/OFF button. 4. Mounting Holes x 3 5. Function Button - Press the button 3 times within 1.5 seconds to send a learn code. - Press and hold the button for 10 seconds, Refer to Removing Device (Exclusion) for details. 6. LED 3 & 2 & 1 (From left to right)
 2Features z LLEEDD  SSttrroobbee  LLiigghhtt 1.  The strobe light includes 3 LEDs (From right to left: LED 3-> LED 2->LED 1). Refer to below table for LED and siren beep for status indication. <<NNOOTTEE>>  ) Arm/Home/Disarm LED and siren beep behaviour are the same under fault conditions (Tamper Fault/Low Battery). zz  AAllaarrmm  AAccttiivvaattiioonn  When an alarm is activated, the Bellbox will activate its siren and strobe light according to different alarm type: z  Burglar and Emergency alarm: Continuous alarm, all LED flashes. z  Fire alarm: 2-second alarm with1-second interval, all LED flashes. zz  AAllaarrmm  LLeennggtthh  SSeettttiinngg  When the Bellbox receives an alarm signal via Z-Wave network, it will activate siren and strobe light according to the alarm length set by the system control panel (default is 10 minutes).   zz  BBaatttteerryy  aanndd  LLooww  BBaatttteerryy  DDeetteeccttiioonn  The Bellbox uses two 1.5V alkaline D-cell batteries as its power source. With the battery, use the battery switch to power on/off the Bellbox manually. The Bellbox features Low Battery Detection function. When the battery voltage is low, the Bellbox will transmit Low Battery signal to the coordinator in Z-Wave network. The Bellbox will report its battery percentage to the Control Panel respectively at 100%, 75%, 50%, 25%, 10%. If the battery voltage is low (10%), a Low Battery signal will be sent to the Control Panel to notify the user. When changing battery, after removing the old battery, press the Tamper Switch twice to fully discharge before inserting new battery. zz  TTaammppeerr  PPrrootteeccttiioonn  The Bellbox is protected by a tamper switch which is compressed against the mounting surface when mounted. Whenever the Bellbox is removed from mounted location, or its cover opened, the tamper switch will be activated and the Bellbox will send a tamper open signal to remind the user of the condition and activate an alarm immediately.   zz  AAddddiinngg  DDeevviiccee  ((IInncclluussiioonn))  This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. z Insert the two 1.5V D-Cell alkaline batteries into the battery compartment connecting the correct polarity as shown on the battery compartment lid. z The Bellbox will emit a 2-tone beep. z Put the Z-Wave gateway or control panel into Inclusion or Learning mode (please refer to the Z-Wave gateway or control panel manual). z Within 1.5 seconds, press the Function Button 3 times. z Refer to the operation manual of the Z-Wave gateway or control panel to complete the learn-in process. z If the sensor has already been included (learnt) into another Z-Wave Gateway/Control Panel, or if the sensor is unable to be learnt into the current Z-Wave Gateway/Control Panel, please exclude it first (see Exclusion) before attempting to include it into the current Z-Wave Gateway/Control Panel.   SSiirreenn  AAuuddiioo  SSttrroobbee  lliigghhtt  iinnddiiccaattiioonn  Arm 1 beep    All 3 LED flash once Home    1 beeps  All 3 LED flash once Disarm 2 beep    Sequentially flash for 1 cycle Entry/Exit Count Down  1 beep per second  None Door Chime  2 tone beeps  None Alarm in Memory  5 beeps  None
 3zz  RReemmoovviinngg  DDeevviiccee  ((EExxcclluussiioonn))  The Bellbox must be removed from existing Z-Wave network before being included into another. There are two methods available to exclude a device. Exclusion Mode z Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave gateway or control panel manual). z Within 1.5 seconds, press the Function Button 3 times and the Bellbox will be removed from the Z-Wave network. Factory Reset (Only use factory reset when network Control Panel/Gateway is missing or inoperable). z Press and hold the Function button of the Smoke Detector for 10 seconds to factory reset with all LED flashes once. <<NNOOTTEE>>  ) Factory resetting the Bellbox will restore it to factory default settings (excluded from the Z-Wave network). The Z-Wave gateway or control panel will still keep its Z-Wave settings. Please refer to the gateway or control panel manual on how to remove the Bellbox’s Z-Wave settings. zz  RRaannggee  TTeesstt   To test whether the device is able to communicate with the Z-Wave gateway or control panel: z Put the gateway / panel into range test mode (Walk Test). z Press the Function Button on the device. z The gateway / panel should display if the device is within the operation range (please refer to the operation manual of the gateway / panel). z Z-Wave Sleep Mode z The Bellbox will enter Z-Wave Sleep mode (to conserve power) after waking up for a short period of time (~10 seconds). While in Z-Wave sleep mode, Z-Wave gateways or control panels are unable to send commands to the Bellbox. z To program the Bellbox, please send command(s) to the Bellbox within the wake-up period.  Installation zz  IInnssttaallllaattiioonn  GGuuiiddeelliinnee  z The Bellbox is designed with a waterproof case to be mounted on external wall of your house. z When mounting the Bellbox, mount as high as possible for its siren and strobe light to attract attention when an alarm is activated. z The Bellbox is designed to be mounted on a flat surface with fixing screws and plugs provided.   z The base has 3 mounting holes for you to screw the Bellbox onto the wall. zz  MMoouunnttiinngg  tthhee  BBeellllbbooxx  1.  Find the location where the Bellbox is to be mounted. 2. Remove the Top cover by releasing the bottom screw using a Philips screwdriver and pulling the outer case out carefully. 3.  Hold the Bellbox at the position where it will be mounted. 4. Check whether BX has a strong enough signal with the Control Panel by putting the Control Panel into Walk Test mode (please refer to Control Panel manual). Press the Function Button check whether the signal is strong enough (please refer to Control Panel manual for signal strength). 5. If you are satisfied with the signal strength, remove the Bellbox from mounting location. 6. Identify the 3 mounting holes, mount and fix the Bellbox on the wall using the large screws and wall plugs provided. Secure the screws using a Philips screwdriver. Make sure the Tamper Switch is fully depressed against the wall.
 4<<NNOOTTEE>>  ) The tamper switch is secured with a button at the back of the base. When the siren is pulled off from the wall, button will be released, the alarm will be activated. Ensure the button is fully depressed when the siren is mounted. If there is a gap, pack with a suitable spacing material. 7.  Replace the Top cover by hooking the top of the Top cover onto the top of the base. Push the bottom of the Top cover onto the base and tighten the bottom screw using a Philips screwdriver. 8.  Check if the installation is successful by testing from the Control Panel by arming and disarming function.  9.  The installation is now completed.  zz  ZZ--WWaavvee  IInnffoorrmmaattiioonn  Device Type: On/Off Power Switch Role Type: Always On Slave (AOS) Command Class Support/Control Mandatory CC Support:  Association CC, v2 or newer       Association Group Information CC       Binary Switch CC       Battery CC       Device Reset Locally CC       Manufacturer Specific CC       Notification CC       Powerlevel CC            Version CC, v2 or newer       Z-Wave Plus Info CC Recommended CC Support: Firmware Update Metadata CC zz  ZZ--WWaavvee’’ss  GGrroouuppss  ((AAssssoocciiaattiioonn  CCoommmmaanndd  CCllaassss  VVeerrssiioonn  22))  The Door Contact can be set to send reports to associated Z-Wave devices. It supports one association groups with five nodes each.   Group 1 for “LifeLine”: Binary Switch CC (SWITCH_BINARY_REPORT) Notification CC,V4 (COMMAND_CLASS_NOTIFICATION)     Battery CC (COMMAND_CLASS_BASIC)     Device Reset Locally CC  Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: . Reorient or relocate the receiving antenna. . Increase the separation between the equipment and receiver. . Connect the equipment into an outlet on a circuit different from that to which the
 5receiver is connected. . Consult the dealer or an experienced radio/TV technician for help.  FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices).   This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and   (2) This device must accept any interference received, including interference that may cause undesired operation.

Navigation menu