INSTALLATION GUIDE
DEC-31.-2013
z SYSTEM INTRODUCTION
The Locator system includes the following components:
Locator (LT-49):
The Locator receives 433 MHZ signal sent from WTR and transmits
the signal in 912 MHZ to Repeater (RPN-99) or Base Unit
(BUN-152).
Repeater (RPN-99): (Optional) The Repeater is an optional device used to relay signal
sent from Locator with same Group number and System ID in 912
MHZ.
Base Unit (BUN-152): The Base Unit receives the signals sent from Locator or Repeater in
912 MHZ and forward the signal to PSTN Dialer via RS232
connection
z SYSTEM OPERATION DIAGRAM
z SYSTEM CAPABILITY:
Each system can have maximum of 4096 LT-49 and 4096 RPN-99.
Each Locator and Repeater has its own ID Code set by a 12-pin Dip Switch.
The frequency hopping technology is adopted in the communication between
Locator, Repeater and BUN-152.
There are three groups of hopping frequency bands are available. Each group
contains 25 channels:
GROUP 1: 906.26 ~ 914.90 MHZ, 25 channels
GROUP 2: 906.38 ~ 915.02 MHZ, 25 channels
GROUP 3: 906.50 ~ 915.14 MHZ, 25 channels
Make sure the distance between BUN-152, RPN-99 and LT-49 is greater than 5
meters. If the distance is too close, the signal may interfere with each other.
BUN-152 Base Unit
z Front View of BUN-152:
LED:
— On: AC Power Supplied
— Flashes: Receiving signal transmission from Locator or Repeater
ANTENNA connector (TNC connector):
— The two connectors for Antenna is used to improve signal reception. During
the installation, be sure to put both Antennas upwards and then screw it
towards the TNC connector.
z Rear View:
RS-232
DC JACK
DC JACK: For connecting to 12V 500mA Power Adaptor
RS-232 CONNECTOR: Connects the RS-232 cable to PSTN Dialer.
TXD
RXD
GND
Pin2: TXD
Pin3: RXD
Pin5: GOUND
Pin 1,4,5,6,7,8,9 : No Connection.
z Interior View:
SW1:
The SW1 switch block contains 3 dip switches for setting Group Frequency.
Slide the SW1 up (On position) with SW2 & SW3 down (Off position), to select
Group1 frequency band. Likewise, slide SW2 or SW3 up (On) with others,
down (Off), Group2 or Group3 is selected accordingly.
SW1
SW2
SW3
Group
On
Off
Off
Group1
Off
On
Off
Group2
Off
Off
On
Group3
GROUP 1 frequency: 906.26 ~ 914.90 MHZ, 25 channels with spacing of
360KHZ between each channel.
GROUP 2 frequency: 906.38 ~ 915.02 MHZ, with spacing of 360KHZ
between each channel.
GROUP 3 frequency: 906.50 ~ 915.14 MHZ, with spacing of 360KHZ
between each channel.
SW2: The SW1 switch block contains 4 dip switches for setting the Base Unit’s
System ID Code, there are total of 16 SYSTEM ID combinations for use from
0 to 15. The Base Station’s System ID setting must be identical to

System ID = 3

) Group and System ID setting must be identical for Base Station and
all Locator and Repeaters.
LT-49 Locator
z Front View:
LED 1 (Green/Red):
Green On: AC Power supplied.
Green Flash: AC Power
disconnected
Red On: Low Battery
LED 2 (Red):.
Red Flash: Receiving signal
from WTR
LED 3 (Red):
Red Flash: Transmitting signal
z Rear View (Lid removed):
DC JACK: For connecting DC 15V 1.2A Power Adaptor.
VR1 :
For adjusting the Locator’s 433MHZ receiver sensitivity. Turn the switch
clockwise to increase radio reception range for WTR. Turn the switch
counter-clock wise to decrease the radio range.
SW1 :
For setting the Group number, please refer to the section “BUN-152”. The
Locator’s Group Number must be identical to the Base Station Group
Number.
SW2 :
For setting the system ID code, please refer to the section “BUN-152”. The
Locator’s System ID must be identical to the Base Station System ID.
SW 3 :
A 12-pin dip switch block to set the “Unit ID Number”.
Each Locator should be assigned an unique ID Number for the Base Station to
distinguish from which locator the signal was transmitted.
12
There are a total of 2 = 4096 combinations for a maximum of 4096 Locators to be
used in one system.

The following examples show you how the “Unit ID” is set (B represents for
Binary, H for Hex and the last numbers represents for Decimal):
UP=1 , DOWN =0
UNIT ID=000100100011B=0123H = 291
UNIT ID=010001010110B=0456H = 1110
UNIT ID=010111001101B=05CDH = 1485
UNIT ID=101010111100B=0ABCH = 2748
SW4:
A 3-pin dip switch block to set the “supervision period”. 8 options are
available as shown in table below:
SW1
SW2
SW3
Supervision Period
Off
Off
Off
Disable
Off
Off
On
1 hour
Off
On
Off
2 hours
Off
On
On
3 hours
On
Off
Off
4 hours
On
Off
On
8 hours
On
On
Off
10 hours
On
On
On
12 hours

If a 2-hour supervision period is set (SW1-off, SW2-On, SW3-off), the
RPN-99 will send the “supervision” signal every 2 hours.
SW 5 : TEST button.
When it is pressed, RPN-99 will automatically sends out a Test signal.
can be used for Range Test.
SW 6:
It
RESET button.
Pressing the button, the RPN-99 will do a power-on Reset and send a
“power-on check-in” signal.
z Power Supply
A DC 15V, 1.2A power adaptor is used to power the Locator.
A 1600mAh x 8 Ni-mh rechargeable battery is used as a back-up power. It takes
approximately 72 hours to fully charge the battery.
z Mounting the Locator
A mounting bracket is included in the Locator package for wall mounting.
1. Use the two holes in the mounting bracket as a template, drill two holes on
the place of desired installation and insert wall plugs if required.
2. Screw the mounting bracket onto drilled hole.
3. Hook the Locator on the bracket.
z Tamper protection
The Locator also features “Tamper protection” after hanging on the mounting
bracket, any attempt to remove it from the mounting bracket will trigger the
tamper switch and the RPN-99 will transmit the “Tamper active” signal
accordingly.
z Queue Buffer
The Locator has a Queue Buffer to store up to 12 signals to be transmitted.
During transmission, the Locator takes the data from the Queue Buffer
one-by-one following First-in-First-out algorithm.
If a signal received already exists in the Queue Buffer, this signal will be ignored.
When the Queue Buffer is full, any signal received will be ignored.
The data being transmitted will be put into another “Time-out Buffer” and a 10-sec
timer will start counting. If a signal received is already in the “Time-out Buffer”,
this signal will also be ignored.
z Changing the Dip Switch setting
The Locator checks the Dip Switch setting only when power is supplied. Be sure
to set the appropriate “Group Number”, “System ID” & “Unit ID” before power it
on.
If it is necessary to charge the Dip Switch setting after power on. Press the
“Reset” button to do the power on Reset, otherwise the change will be ignored.
Repeater RPN-99
z Front View:
LED 1 (Green/Red):
Green On: AC Power supplied.
Green Flash: AC Power
disconnected
Red On: Low Battery
LED 2 (Red):.
Red Flash: Receiving signal
from Locator or other Repeater
LED 3 (Red):
Red Flash: Transmitting signal
z Rear View (Lid removed):
DC JACK: For connecting DC 15V 1.2A Power Adaptor.
SW 1 :
For setting the Group number, please refer to the section “BUN-152”. The
Repeater’s Group Number must be identical to the Base Station Group
Number.
SW 2 :
For setting the system ID code, please refer to the section “BUN-152”. The
Repeater’s System ID must be identical to the Base Station System ID.
SW 3 :
A 12-pin dip switch block to set the “Unit ID Number”. Refer to Locator
section for setting detail.
SW 4 :
A 3-pin dip switch block to set the “supervision period”. Refer to Locator
section for setting detail.
SW 5 : TEST button. Refer to Locator section for detail.
SW 6 : RESET button. Refer to Locator section for detail.
Refer to Locator section for Repeater operation guideline.
Specification Radio Frequency
1) BUN-152/RPN-99/LT-49 (900M Channels):
Frequency Hopping: Each group has a total of 25 channels.
There are 3 groups in total.
Its frequency is as followed:
Group1: 906.26 ~ 914.90MHZ
Group2: 906.38 ~ 915.02MHZ
Group3: 906.50 ~ 915.14MHZ
Modulation: FM
Frequency deviation: 11.7KHZ
Data speed: 9.6K
Sensitivity: -102dBm
Band Width: 20KHZ
Channel separation: 360KHZ
Output Power: 28dBm
Frequency Tolerance: +/- 3ppm
Antenna: Dual antenna for receiver to avoid signal fading and dark spot separate
antenna for transmitter.
Communication method: full Duplex, Transmission and receiving are able to be carried
on simultaneously.
Range: Over 3 KM in open space.
2) 433.92MHZ Channel
Frequency: 433.92MHZ +/- 100KHZ
Modulation: AM (100%)
Sensitivity: -117dBm
Distance of Receiving range: 6 ~ 100 Meter (adjustable)
Communication method: Full duplex.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or modifications not expressly
approved by the party responsible for compliance could void the user's authority to operate this
equipment. (Example - use only shielded interface cables when connecting to computer or
peripheral devices).
FCC Radiation Exposure Statement
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of 20
centimeters between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
The antennas used for this transmitter must be installed to provide a separation distance of at least
20 cm from all persons and must not be co-located or operating in conjunction with any other
antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
10

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2015:12:29 11:49:14+08:00
Create Date                     : 2015:12:29 11:49:14+08:00
Format                          : application/pdf
Title                           : Microsoft Word - BUN-RPN-LT user manual + FCC statement.doc
Creator                         : TEST
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:8cf47b17-a0e4-486c-8559-b39337993893
Instance ID                     : uuid:d4b0ba38-8ed1-4c5b-a520-96ec3ed11f54
Page Count                      : 10
Author                          : TEST
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GX9G4LT

Navigation menu