Climax Technology Co PS Power Switch User Manual manual

Climax Technology Co Ltd Power Switch manual

Users Manual

 1PSS-29ZBS Power Switch  Introduction PSS-29ZBS is a ZigBee Power Switch. It is capable of receiving wireless signals from the coordinator in the Zigbee network to toggle On/Off of appliances that are attached to it.   The  Power  Switch  utilizes  ZigBee  technology  for  wireless  signal  transmission.  ZigBee  is  a  wireless communication  protocol  that  is  reliable,  has  low  power  consumption  and  has  high  transmission efficiency.  Based  on  the  IEEE802.15.4  standard,  ZigBee  allows  a  large  amount  of  devices  to  be included in a network and coordinated for data exchange and signal transmission. The  Power  Switch  serves  as  an  end  device  in  the  ZigBee  network.  It  can  be  included  in  the  ZigBee network  to  transmit  or  receive  signal,  but  cannot  permit  any  other  ZigBee  device  to  join  the  network through the Power Switch.  Parts Identification 1. Function Button aka LED indicator The  Function  Button  also  doubles  as  the  LED  Indicator.  The function button is used to control the Power Switch. The LED indicator is used to indicate Power Switch status.     LED Indication:     The LED indicator lights up in the following conditions: - On: The Power Switch is turned on.   - Off: The Power Switch is turned off.   - Flashes twice: The Power Switch has successfully joined a ZigBee network.   - Flashes once every 20 minutes: The Power Switch is not joined into any ZigBee network, or has lost connection to its current ZigBee network. - Flashes three times The Power Switch has successfully bound with a controller - Flashes five times The Power Switch was unable to bind with a controller Function Button Usage:     - Press the button to toggle on/off the Power Switch - Press and hold the button for 10 seconds then release to reset the Power Switch. - Press and hold the button for 3 seconds then release to bind with a controller  ZigBee Network Setup   ZZiiggBBeeee  DDeevviiccee  GGuuiiddeelliinnee  ZigBee is a wireless communication protocol that is reliable, has low power consumption and has high transmission efficiency. Based on the  IEEE802.15.4  standard,  ZigBee  allows  a  large  amount  of devices  to  be  included  in  a  network  and  are  coordinated  for  data exchange and signal transmission.   JJooiinniinngg  tthhee  ZZiiggBBeeee  NNeettwwoorrkk  As  a  ZigBee  device,  the  Power  Switch  needs  to  join  a  ZigBee network  to  receive  commands  and  transmit  energy  consumption information. Please follow the steps bellow to join the Power Switch into a ZigBee network. Case A Case B Case C
 21. Plug in the Power Switch into a power outlet. 2.  Press  and  hold  the  function  button  for  10  seconds  as  the  Power  Switch  resets  and  starts searching for existing ZigBee network. Please make sure the permit-to-join feature on the router or coordinator of your ZigBee network is enabled. 3.  If  the  Power  Switch  successfully  joins  a  ZigBee  network,  the  LED  Indicator  will  flash  twice  to confirm. 4. After joining the ZigBee network, the Power Switch will be registered in the network automatically. Please  check  the  Zigbee  network  coordinator,  system  control  panel  or  CIE  (Control  and Indicating Equipment) to confirm if joining and registration is successful. 5.  If  registration  and  joining  to  the  network  is  unsuccessful,  the  Power  Switch  LED  indicator  will flash  every  20  minutes  after  warming  up  to  indicate  the  situation.  Please  check  your  ZigBee network coordinator, system control panel or CIE setting to ensure the permit-to-join function is available, and then use the Factory Reset function below to join the ZigBee network.   BBiinnddiinngg  wwiitthh  CCoonnttrroolllleerr  After joining  the  ZigBee  network,  the Power  Switch can  bind  itself with  a controller  device  which can be used to turn on/off the Power Switch. To bind the Power Switch and the device: 1. Press and hold  the Function Button for 3 seconds, then release the button. The  Power  Switch will send binding request to the coordinator. 2. Refer to your controller manual to send binding request for the device within 16 seconds. 3. If binding  is successful, the  Power Switch  LED  indicator  will flash  3  times  to  confirm. You  can now use the controller to adjust power output level for the Power Switch. 4. If  binding  is  unsuccessful,  the  Power  Switch  LED  indicator  will  flash  5  times.  Please  retry  the binding process.   FFaaccttoorryy  RReesseett  If you want to remove the Power Switch from current network and join a new network, you need to use  the  Factory Reset  function  to clear  the  Power Switch  from  its stored  setting  and information first before it can join another network. To perform Factory Reset: 1. Press and hold the switch button for 10 seconds, release the button until the LED Indicator flash once.   2.  The  Power  Switch  has  been  reset  to  factory  default  setting  with  all  its  previous  network information removed. It will now actively search for available ZigBee network again and join the network automatically.   3.  If  the  Power  Switch  successfully  joins  a  ZigBee  network,  the  LED  Indicator  will  flash  twice  to indicate. 4. If the Power Switch cannot find an available ZigBee network, the LED Indicator will flash every 20 minutes to indicate.  Operation   IInnssttaallllaattiioonn    Plug the Power Switch into a power outlet.    Plug the appliance into the socket of the Power Switch. The appliance must be in ON status.   AApppplliiaannccee  CCoonnttrrooll    After  the  Power  Switch  has  successfully  joined  a  ZigBee  network,  the  coordinator  can remotely turn on/off the Power Switch to control the appliance   You can also press the button on the Power Switch to toggle its on/off status   If you have bound a controller with the Power Switch, you can also use the controller to turn on/off the Power Switch.   If  the  Power  Switch  is  removed  from  power  outlet,  after  replugging  the  Power  Switch,  its previous on/off status will be restored within 1 minute   MMaaxxiimmuumm  OOppeerraattiioonn  LLooaadd    For 110V: the maximum operation load is 1760W and 16A.       For 230V: the maximum operation load is 3680W and 16A.
 3Appendix (For developers only)   PPoowweerr  SSwwiittcchh  CClluusstteerr  IIDD  Device ID: On Off Output :0x0002 Endpoint:0x0A Server Side  Client  Side Mandatory Basic (0x0000)  None Identify(0x0003)   Groups(0x0004)   Scenes(0x0005)   On/Off(0x0006)   Optional None  None   AAttttrriibbuuttee  ooff  BBaassiicc  CClluusstteerr  IInnffoorrmmaattiioonn  Identifier Name  Type  Range  Access Default Mandatory / Optional 0x0000  ZCLVersion Unsigned 8-bit integer 0x00 –0xff  Read only  0x01  M 0x0001  ApplicationVersion Unsigned 8-bit integer 0x00 –0xff  Read only  0x00  O 0x0003  HWVersion Unsigned 8-bit integer 0x00 –0xff  Read only  0  O 0x0004  ManufacturerName  Character String  0 – 32 bytes Read only  Climax Technology O 0x0005  ModelIdentifier  Character String  0 – 32 bytes Read only  PSS_00.00.00.14TC O 0x0006  DateCode  Character String  0 – 16 bytes Read only  O  0x0007  PowerSource  8-bit  0x00 –0xff  Read only    M 0x0010  LocationDescription  Character String  0 – 32 bytes Read / Write    O 0x0011  PhysicalEnvironment  8-bit  0x00 –0xff  Read / Write  0x00  O 0x0012  DeviceEnabled  Boolean  0x00 –0x01 Read / Write  0x01  M   AAttttrriibbuuttee  ooff  IIddeennttiiffyy  CClluusstteerr  IInnffoorrmmaattiioonn  Identifier Name  Type  Range  Access Default Mandatory / Optional 0x0000  IdentifyTime  Unsigned 16-bit integer 0x00 –0xffff Read / Write  0x0000  M   AAttttrriibbuutteess  ooff  tthhee  GGrroouuppss  cclluusstteerr  IInnffoorrmmaattiioonn  Identifier Name  Type  Range  Access Default Mandatory / Optional 0x0000  NameSupport  8-bit bitmap x0000000 Read only -  M   AAttttrriibbuutteess  ooff  tthhee  SScceenneess  cclluusstteerr  IInnffoorrmmaattiioonn  Identifier Name  Type  Range  Access Default Mandatory / Optional 0x0000  NameSupport  8-bit bitmap x0000000 Read only 0x00  M 0x0001  CurrentScene  Unsigned 8-bit integer 0x00 – 0xff Read only 0x00  M 0x0002  CurrentGroup  Unsigned 16-bit 0x0000 – 0xfff7 Read only 0x00  M
 4integer 0x0003  SceneValid  Boolean  0x00 – 0x01 Read only 0x00  M 0x0004  NameSupport  8-bit bitmap  x0000000  Read only -  M   AAttttrriibbuuttee  ooff  OOnn//OOffff  CClluusstteerr  IInnffoorrmmaattiioonn  Identifier  Name  Type  Range  Access  Default  Mandatory / Optional 0x0000  OnOff  Boolean  0x00 –0x01  Read only  0x00  M   Federal Communication Commission Interference Statement  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: . Reorient or relocate the receiving antenna. . Increase the separation between the equipment and receiver. . Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. . Consult the dealer or an experienced radio/TV technician for help.  FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices).  FCC Radiation Exposure Statement  This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. “This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.”   This device complies with Part 15 of the  FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept  any  interference  received,  including  interference  that  may  cause undesired operation.

Navigation menu