Climax Technology Co WSLD Water Sensor User Manual WS LD 20060126 1User Menu

Climax Technology Co Ltd Water Sensor WS LD 20060126 1User Menu

User Manual

Download: Climax Technology Co WSLD Water Sensor User Manual WS LD 20060126 1User Menu
Mirror Download [FCC.gov]Climax Technology Co WSLD Water Sensor User Manual WS LD 20060126 1User Menu
Document ID708122
Application ID73TSG3Vx7Igje7XvZurhIw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize29.11kB (363856 bits)
Date Submitted2006-09-22 00:00:00
Date Available2006-09-25 00:00:00
Creation Date2006-09-15 02:10:37
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2006-09-19 11:06:51
Document TitleMicrosoft Word - WS-LD 20060126-1User Menu.DOC
Document CreatorPScript5.dll Version 5.2
Document Author: ritahuang

WS-LD Water Sensor
Water Sensor is specially designed to detect if the water level is above a certain level that may damage your
protected goods. It is a device that helps to manage your protected place and goods by keeping it nice and
dry.
Identifying the parts:
Antenna
Learn / Test button
This button is used for testing the radio performance
and for learning purpose.
Probe
Battery lid
This Probe is used for detecting the increasing water
level.
Buzzer
Extension black wire with Probe
Battery:
The WS-LD uses one 9V alkaline battery as its power source. The battery is good for at least 3 years
before it needs changing.
Low battery detection operates at a threshold of 3.3V ±10 % where the WS-LD has enough reserve
power to typically operate for 3 months before complete exhaustion. The WS-LD low battery signal will
be enunciated by one beep for every 45 secs.

WS-LD will perform one beep when the power is on.
WS-LD will only send low battery signal every 24 hrs after continuous 10 hrs of low battery
detection.
WS-LD will only detect the low battery when an alarm has been activated. The low battery
signal will be sent to the Control Panel along with the alarm signal transmission for the
Control Panel to display the status accordingly.
GETTING STARTED:
I. For CTC-1002:
Remove the screw to separate the top cover from the base.
Insert the battery with negative of the battery on the spring side.
Place the top case over the base.
Put the Control Panel into “Device +/-“ menu and ten select “Add Device” menu.
Press any buttons on the WS-LD
Refer to the operation manual of your control panel under the section of “Device +/-“ to
complete the learn-in process.
WS-LD.DOC
2006.01.26
II. For VCM:
Remove the battery lid by pushing and sliding it with the direction of arrow on the bottom of
WS-LD
Insert the battery with negative of the battery on the spring side.
Clips the battery lid to the base.
Program the VCM by pressing and holding the red button on the bottom for 5 secs, a short
beep will be sound. Then release the button, VCM will perform a long beep will with LED On..
Press the red button on WS-LD.
VCM will perform two beeps with LED flash if the signal received successfully and completes
the learning-in procedures.

VCM will perform one short beep indicating that the WS-LD is already in the system.
MOUNTING WS-LD:
I.
Clean the surface with a suitable degreaser.
II. Remove the protective covering from one side of the double-sided adhesive pad
and firmly apply to the back of the device.
III. Next remove the other cover and firmly press the item onto the desired location.

Do not use the adhesive pad method of installation on a surface with peeling or cracked
paint, or on a rough surface.
NORMAL OPERATION:
Mount the WS-LD on the wall whereas drop the black wire onto the floor level or any height that you
want to detect the increasing water level.
When the probes first come in contact with water, WS-LD gives out continuous warning
beeps at a 50% duty cycle for every two seconds, and sends an alarm signal to the
control panel every two minutes to notify the user.
With water condition persists, WS-LD will keep performing the warning beeps and
sending the alarm signal to the control panel

After probes are no longer in contact with water, the warning beeps will be eliminated and
WS-LD sends a restore signal to the Control Panel indicating the water condition has been
cleared. WS-LD then enters Normal Operation Mode.
During the alarming period, whenever the water ebbs, WS-LD enters Normal Operation
Mode.
Supervisory Signal
After installation, the WS-LD will automatically transmit Supervisory Signals periodically to the Control
Panel at intervals of 24 hrs randomly.
WS-LD.DOC
2006.01.26
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
CAUTION:
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference and
(2) This device must accept any interference received, including interference that may
cause undesired operation.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2006:09:15 02:10:37Z
Modify Date                     : 2006:09:19 11:06:51+08:00
Page Count                      : 3
Creation Date                   : 2006:09:15 02:10:37Z
Mod Date                        : 2006:09:19 11:06:51+08:00
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : ritahuang
Metadata Date                   : 2006:09:19 11:06:51+08:00
Creator                         : ritahuang
Title                           : Microsoft Word - WS-LD 20060126-1User Menu.DOC
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GX9WSLD

Navigation menu