Codan 3020 HF Radio Supply Transceiver

User Manual: Codan 3020 HF Radio Supply HF Supplies, Amplifiers, Remote Control & Interconnects | LMR & HF Radio | Codan Radio

Open the PDF directly: View PDF PDF.
Page Count: 2

www.codanradio.com © Copyright 2012
FEATURES AT A GLANCE
Rugged design
Stable regulation
Low noise output
Uninterrupted supply
The 3020 Transceiver Supply is designed to interface
with CODAN™ Transceivers for voice, data or fax
communications. It operates over a wide range of
mains supply voltages, providing full auto-ranging
between 100 and 240 V nominal.
RUGGED DESIGN
The 3020 Transceiver Supply is small, lightweight and rugged. It is
designed to withstand the toughest conditions by providing:
Input protection against input mains voltage uctuations that
may vary outside normal tolerances.
Output protection from over-load and short circuits, as well
as automatic shutdown for over and undervoltage conditions.
Thermal protection against extreme ambient temperatures and
poor ventilation through fan cooling and over
temperature shutdown.
STABLE REGULATION
Output voltage regulation provided by the 3020 is extremely stable
with a variation of less than 0.1% from no load to full rated output
of 20 Amps.
LOW NOISE OUTPUT
For best performance, HF transceivers require an extremely low noise
power source so that receiver sensitivity is not degraded. The 3020
delivers less than 100 mV of ripple and noise.
UNINTERRUPTED SUPPLY
The 3020 is capable of charging an externally connected lead-acid
battery. When used with a fl oat charge cable kit, the 3020 provides
a continuous supply to the transceiver in the event of a mains failure.
12-20045 Issue 14 3/2012
3020 TRANSCEIVER SUPPLY
T: +61 8 8305 0311 F: +61 8 8305 0411 E: sales@codanradio.com
Codan Limited 81 Graves Street Newton South Australia 5074 Australia
RADIO COMMUNICATIONS
www.codanradio.com
SPECIFICATIONS
Input voltage 100 to 240 V AC ±10% (50/60 Hz)
Input VA 250 VA at 16 A DC output current
Output voltage 13.8 V DC
Output current 16 A DC continuous duty to 60°C ambient
20 A DC on peak speech
Output regulation Less than 0.1% over no-load through to full load conditions for full input voltage range
Ripple & noise <100 mV
Cooling Fan forced air — thermally controlled
Size & weight 210 mm W x 230 mm D x 80 mm H; 1.9 kg
Mains connection Via IEC type socket at rear of unit
3020 TRANSCEIVER SUPPLY
CODAN™ is a trademark of Codan Limited. Other
brand, product and company names mentioned in
this document are trademarks or registered trademarks
of their respective holders.
Values noted are typical. Equipment descriptions and specifi cations subject to change without notice or obligation.
12-20045 Issue 14 3/2012