036-21603-002 Rev. A (1004)

DESCRIPTION
These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer
tubular heat exchangers. The units are factory shipped for
installation in upflow or horizontal applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage
and are also ideal for commercial applications. All units are
factory assembled, wired and tested to assure safe dependable and economical installation and operation.
These units are Category I listed and may be common
vented with another gas appliance as allowed by the
National Fuel Gas Code.

TECHNICAL GUIDE
Echelon
MODELS: FC8T/LC8T
GAS-FIRED
HIGH EFFICIENCY TWO STAGE
UPFLOW/HORIZONTAL FURNACES

WARRANTY

STANDARD & LoNOx

20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applications.
5-year limited parts warranty.

80% AFUE

FEATURES
•

NATURAL GAS
60 - 120 MBH INPUT

•
•
•
•
•
•
•
•
•
•
•
•
•
EFFICIENCY
RATING
CERTIFIED

•

This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.

•
•
•
•

Due to continuous product improvement, specifications
are subject to change without notice.

•
•

Visit us on the web at www.york.com for the most
up-to-date technical information.

•

Additional rating information can be found at
www.gamanet.org.

•

Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
Provides increased comfort level & very quiet unit operation
Adjustable delay timer allows two stage operation with
single stage thermostat
Compact, easy to install, ideal height 40" cabinet
Blower-off delay for cooling SEER improvement.
Easy to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement application.
Integrated control module for reliable, economical operation.
High velocity filter and side -return filter rack provided for
easy field installation.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
Induced combustion system with inshot main burners for
quiet, efficient operation.
100% shut off main gas valve for extra safety.
PSC -four speed, direct drive motor with large, quiet
blower.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Timed on, adjustable off blower capability for maximum
comfort.
Solid removable bottom panel allows easy application.
Easy access from front of unit for cleaning, maintenance
or service.
Insulated blower compartment for quiet operation.
Independent door removal for greater durability and ease
of access.
LoNOx models have been designed to meet specific code
requirements.
LoNOx models may not be converted to propane.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

036-21603-002 Rev. A (1004)
D

A

20

(VENT CONNECTIONS)
POWER WIRING
7/8” HOLE

14-3/4

13-3/4
5-3/8

2-1/2
40

32-1/2
ACCESS
WIRING
7/8” K.O.

GAS INLET
1-1/4 x 2-1/2

2
14

16
2-1/4

23-1/2
8-3/4

1-1/8

30-1/8

RIGHT SIDE

LEFT SIDE

FRONT

1-3/8
26-3/4

C

T’STAT WIRING
7/8” K.O.
5/8
20

1-1/4

5/8

D

B

4” Diameter

BOTTOM IMAGE
RETURN END

24-3/4

TOP IMAGE
SUPPLY END

CABINET AND DUCT DIMENSIONS
Model

BTUH Output
MBH

CFM

Cabinet Size

Cabinet Dimension
A

B

C

D

(F,L)C8T060A12UH11

46/34

1200

A

14 1/2

13 1/4

10 1/8

10 1/8

(F,L)C8T080A12UH11

64/48

1200

A

14 1/2

13 1/4

10 1/8

10 1/8

(F,L)C8T080B16UH11

64/48

1600

B

17 1/2

16 1/4

13 1/8

11 5/8

FC8T100B12UH11

80/53

1200

B

17 1/2

16 1/4

13 1/8

11 5/8

(F,L)C8T100C20UH11

80/53

2000

C

21

19 3/4

16 5/8

13 3/8

FC8T120C16UH11

96/64

1600

C

21

19 3/4

16 5/8

13 3/8

(F,L)C8T120C20UH11

96/64

2000

C

21

19 3/4

16 5/8

13 3/8

HORIZONTAL VENTING - MUST USE FIELDS CONTROL MODELS SWG-4Y OR TJERENLAND MODEL GPAK-JT FIELD
SUPPLIED POWER VENTING KITS

2

Furnace
Airflow

Pipe Size

High / Low
Fire Inputs

High / Low
Fire Outputs

Cabinet

BTU/H

BTU/H

Width

CFM

Feet

Feet

60/42

46/34

A

1200

4

4.5

34.5

80/59

64/48

A

1200

4

4.5

34.5

80/59

64/48

B

1600

4

4.5

34.5

100/65

80/53

B

1200

4

4.5

34.5

100/65

80/53

C

2000

4

4.5

34.5

120/78

96/64

C

1600

4

4.5

34.5

120/78

96/64

C

2000

4

4.5

34.5

Inches

Min. Vent Length Max. Vent Length

Unitary Products Group

036-21603-002 Rev. A (1004)
RATINGS & PHYSICAL / ELECTRICAL DATA
Output

Model

Cabinet
Width

Nominal

Max. Outlet
Air Temp.

Air Temp. Rise

AFUE

MBH

CFM

In.

(F,L)C8T060A12UH11

46/34

1200

14-1/2

(F,L)C8T080A12UH11

64/48

1200

14-1/2

80.0

30-60

175

(F,L)C8T080B16UH11

64/48

1600

17 1/2

80.0

25-55

160

80.0

°F

°F

25-55

165

FC8T100B12UH11

80/53

1200

17 1/2

80.0

25-55

170

(F,L)C8T100C20UH11

80/53

2000

21

80.0

25-55

160

FC8T120C16UH11

96/64

1600

21

80.0

25-55

180

(F,L)C8T120C20UH11

96/64

2000

21

80.0

25-55

170

Output

Blower

Blower
Size

Total
Unit

Min.
Wire
one way

Operation
WGT.
107

MBH

Hp

Amps

In.

Amps

Max Over-current
Size (awg) @
75 ft.protect

(F,L)C8T060A12UH11

46/34

1/3

6.2

10 x 7

9.0

20

14

(F,L)C8T080A12UH11

64/48

1/3

6.2

10 x 7

9.0

20

14

119

(F,L)C8T080B16UH11

64/48

3/4

11.5

11 x 8

12.0

20

14

129

Model

LBS

FC8T100B12UH11

80/53

1/2

7.0

10 x 8

12.0

20

14

131

(F,L)C8T100C20UH11

80/53

1.0

12.2

11 x 10

14.0

20

12

149

FC8T120C16UH11

96/64

1/2

10.4

10 x 10

12.0

20

14

149

(F,L)C8T120C20UH11

96/64

1.0

12.2

11 x 10

14.0

20

12

151

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.

FILTER SIZES
Cabinet Size

Side (in)

Bottom (in)

A

16 x 26

14 x 26

B

16 x 26

16 x 26

C

(2) 16 x 26

20 x 26

D

(2) 16 x 26

20 x 26

* ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil.
NOTES:
1. All filters must be high velocity cleanable type.
2. Air flows above 1800 CFM require either return from two sides or one side plus bottom.

Unitary Products Group

3

036-21603-002 Rev. A (1004)
TABLE 1: Blower Performance CFM - Upflow (without filter) - Bottom Return
Two Stage Bottom Airflow Data (SCFM)

MODELS
Input /
CFM

(F,L)C8T060A12UH11

(F,L)C8T080A12UH11

(F,L)C8T080B16UH11

FC8T100B12UH11

(F,L)C8T100C20UH11

FC8T120C16UH11

FC8T120C16UH11

Speed

High
Medium High
Medium Low
Low
High
Medium High
Medium Low
Low
High
Medium
Low
High
Medium High
Medium Low
Low
High
Medium High
Medium Low
Low
High
Medium
Low
High
Medium High
Medium Low
Low

Ext. Static Pressure (in. H2O)
0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1570
1410
1200
960
1590
1400
1180
940
1850
1470
1260
1700
1430
1180
950
2590
2180
1750
1450
2020
1750
1540
2500
2130
1700
1420

1490
1360
1180
960
1520
1360
1160
940
1820
1450
1260
1620
1400
1170
950
2500
2120
1720
1420
1930
1710
1500
2400
2070
1680
1390

1420
1310
1150
950
1460
1310
1130
940
1790
1440
1260
1560
1350
1160
930
2400
2040
1680
1380
1820
1650
1460
2320
1990
1650
1360

1340
1250
1100
930
1380
1260
1090
920
1750
1430
1260
1480
1300
1130
920
2280
1980
1640
1330
1730
1590
1410
2220
1920
1620
1330

1250
1190
1050
900
1300
1200
1040
880
1690
1390
1250
1390
1230
1080
880
2180
1900
1580
1300
1640
1490
1350
2110
1840
1560
1290

1180
1090
990
840
1240
1140
990
840
1630
1360
1200
1300
1160
1030
840
2080
1810
1520
1240
1540
1390
1260
2000
1760
1500
1240

1090
1020
920
800
1150
1070
920
790
1570
1310
1150
1210
1080
1000
790
1970
1720
1440
1160
1400
1290
1180
1870
1660
1410
1150

990
920
830
720
1050
960
840
710
1500
1270
1110
1110
980
860
720
1840
1600
1350
1070
1250
1160
1060
1750
1570
1320
1060

870
810
700
610
930
860
750
630
1430
1220
1070
970
870
750
620
1720
1480
1220
970
1090
1010
910
1610
1460
1210
950

700
650
580
500
800
740
640
530
1330
1150
1010
820
710
510
530
1560
1320
1060
860
920
810
750
1450
1320
1070
840

NOTES

1. Airflow expressed in standard cubic feet per minute (CFM) and in cubic meters per minute (m3/min).
2. Motor voltage at 115 V.
* Input / CFM / Cabinet Width (A=14-1/2, B=17-1/2, C=21, D=24-1/2).

4

Unitary Products Group

036-21603-002 Rev. A (1004)
TABLE 2: Blower Performance CFM - Upflow (without filter) - Left Side Return
Two Stage Left Side Airflow Data (SCFM)

MODELS
Input /
CFM

Speed

(F,L)C8T060A12UH11

(F,L)C8T080A12UH11

(F,L)C8T080B16UH11

FC8T100B12UH11

(F,L)C8T100C20UH11

FC8T120C16UH11

FC8T120C16UH11

High
Medium High
Medium Low
Low
High
Medium High
Medium Low
Low
High
Medium
Low
High
Medium High
Medium Low
Low
High
Medium High
Medium Low
Low
High
Medium
Low
High
Medium High
Medium Low
Low

Ext. Static Pressure (in. H2O)
0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1770
1400
1120
880
1790
1420
1080
N/A
2000
1440
1220
1780
1430
1140
920
2770
2120
1690
1390
2160
1760
1510
2740
2120
1690
1390

1690
1380
1130
900
1720
1370
1120
900
1960
1440
1230
1710
1410
1170
940
2670
2060
1660
1370
2070
1720
1490
2650
2090
1670
1360

1630
1350
1150
900
1670
1350
1110
900
1930
1430
1230
1640
1370
1150
950
2610
2030
1630
1330
1990
1690
1470
2560
2040
1650
1330

1560
1320
1130
900
1590
1320
1100
890
1900
1420
1230
1560
1340
1120
940
2540
2000
1610
1290
1900
1630
1440
2480
2000
1610
1300

1490
1280
1120
880
1530
1280
1080
870
1800
1400
1200
1490
1280
1080
920
2450
1950
1560
1250
1800
1560
1380
2380
1940
1560
1250

1390
1230
1080
850
1450
1230
1040
850
1760
1380
1190
1390
1220
1040
890
2340
1880
1490
1200
1690
1480
1300
2280
1870
1510
1190

1290
1160
1000
790
1350
1170
1000
800
1710
1340
1170
1290
1140
970
850
2210
1810
1420
1120
1580
1390
1210
2170
1780
1440
1100

1190
1060
950
730
1260
1090
920
730
1640
1300
1160
1180
1040
890
770
2070
1720
1350
1010
1430
1250
1110
1990
1680
1310
1020

1050
930
790
660
1140
990
820
670
1550
1220
1110
1030
890
760
660
1890
1580
1240
910
1260
1080
950
1840
1550
1160
940

920
780
630
530
1000
840
690
560
1460
1150
1050
820
730
630
560
1730
1370
1070
850
1000
890
780
1650
1370
1030
840

NOTES

1. Airflow expressed in standard cubic feet per minute (CFM) and in cubic meters per minute (m3/min).
2. Return air is through side opposite motor (left side).
3. Motor voltage at 115 V.
* Input / CFM / Cabinet Width (A=14-1/2, B=17-1/2, C=21, D=24-1/2).
X/L C G R W2 W1 Y2 Y1

BLK

BLK (HOT)

WHT

WHT (NEUTRAL)

GRN

GRN

TWO-STAGE
THERMOSTAT

NOMINAL
120 VOLT

INTEGRATED
CONTROL
T’STAT
COMMON
CONNECTION

OUTDOOR
UNIT
Y1
Y2

Y2 W1
Y W

Y

C
X/L

W2

W1
R

R
Y1

SINGLE STAGE
THERMOSTAT

G

R

C

G
C

T’STAT
COMMON
CONNECTION

Field Wiring for Two Stage Thermostat

Field Wiring for Single Stage Thermostat

Unitary Products Group

5

036-21603-002 Rev. A (1004)

FILTER PERFORMANCE

NOTE: The filter pressure drop values in the “Filter Performance” table shown below are typical values for the type of
filter listed and should only be used as a guideline. Actual
pressure drop ratings for each filter type vary between filter
manufacturer.

The airflow capacity data published in the “Blower Performance” table listed above represents blower performance
WITHOUT filters. To determine the approximate blower performance of the system, apply the filter drop value for the filter being used or select an appropriate value from the “Filter
Performance” table shown below.
FILTER PERFORMANCE - PRESSURE DROP INCHES W.C.

CFM
0 - 750
751 - 1000
1001 - 1250
1251 - 1500
1501 - 1750
1751 - 2000
2001 & Above

Filter Type

Minimum Opening Size

Airflow
Range

1 Opening
In³
230
330
330
330
380
380
463

Disposable

2 Openings
In³

1 Opening
inwc
0.01
0.05
0.1
0.1
0.15
0.19
0.19

658
658
658

WASHABLE FIBER*

2 Openings
inwc

0.09
0.11
0.11

1 Opening
inwc
0.01
0.05
0.1
0.1
0.14
0.18
0.18

2 Openings
inwc

0.08
0.1
0.1

Pleated
1 Opening
inwc
0.15
0.2
0.2
0.25
0.3
0.3
0.3

2 Openings
inwc

0.17
0.17
0.17

* Washable fiber are the type supplied with furnace (if supplied).

APPLYING FILTER PRESSURE DROP TO
DETERMINE SYSTEM AIRFLOW
To determine the approximate airflow of the unit with a filter in place,
follow the steps below:
1.

Select the filter type.

2.

Select the number of return air openings or calculate the return
opening size in square inches to determine the proper filter
pressure drop.

3.

Determine the External System Static Pressure (ESP) without
the filter.

4.

Select a filter pressure drop from the table based upon the number of return air openings or return air opening size and add to
the ESP from Step 3 to determine the total system static.

5.

If total system static matches a ESP value in the airflow table
(i.e. 0.20 w.c. (50 Pa), 0.60 w.c. (150 Pa), etc,) the system airflow corresponds to the intersection of the ESP column and
Model/Blower Speed row.

6.

If the total system static falls between ESP values in the table
(i.e. 0.58 w.c. (144 Pa), 0.75 w.c. (187 Pa), etc.), the static pressure may be rounded to the nearest value in the table determining the airflow using Step 5 or calculate the airflow by using the
following example.

Example: For a 130,000 BTUH (38.06 kW) furnace with 2 return
openings and operating on high-speed blower, it is found that total
system static is 0.58” w.c. To determine the system airflow, complete
the following steps:
Obtain the airflow values at 0.50 w.c. (125 Pa) & 0.60 w.c. (150 Pa)
ESP.
Airflow @ 0.50”: 2125 CFM (60.17 m3/min)
Airflow @ 0.60”: 2035 CFM (57.62 m3/min)
Subtract the airflow @ 0.50 w.c. (125 Pa) from the airflow @ 0.60
w.c. (150 Pa) to obtain airflow difference.
2035 - 2125 = -90 CFM (2.55 m3/min)
Subtract the total system static from 0.50 w.c. (125 Pa) and divide
this difference by the difference in ESP values in the table, 0.60 w.c.
(150 Pa) - 0.50 w.c. (125 Pa), to obtain a percentage.
(0.58 - 0.50) / (0.60 - 0.50) = 0.8
Multiply percentage by airflow difference to obtain airflow reduction.
(0.8) X (-90) = -72
Subtract airflow reduction value to airflow @ 0.50 w.c. (125 Pa) to
obtain actual airflow @ 0.58 inwc (144 Pa) ESP.
2125 - 72 = 2053

UNIT CLEARANCES TO COMBUSTIBLES (ALL DIMENSIONS IN INCHES)
(ALL SURFACES IDENTIFIED WITH THE UNIT IN AN UPFLOW CONFIGURATION)
TOP FRONT REAR LEFT SIDE RIGHT SIDE

FLUE

LINE
CONTACT

In.

In.

In.

In. (cm)

In. (cm)

In. (cm)

FLOOR/
BOTTOM

1

6

0

0

31

6

COMBUSTIBLE

YES

YES

YES

UPFLOW B-VENT

1

3

0

0

0

1

COMBUSTIBLE

YES

YES

YES

NO

HORIZONTAL

32

6

0

1

0

6

COMBUSTIBLE

NO

YES

YES

YES3

HORIZONTAL B-VENT

0

3

0

1

0

1

COMBUSTIBLE

NO

YES

YES

YES3

APPLICATION
UPFLOW

1
2
3

6

CLOSET ALCOVE ATTIC

NO

14-1/2” cabinet models only. All other units “0” clearance.
14-1/2” cabinet left airflow applications only. All other units and right hand airflow applications “0” clearance.
Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of the furnace jacket and building joists, studs or
framing.

Unitary Products Group

036-21603-002 Rev. A (1004)

ACCESSORIES
PROPANE (LP) CONVERSION KIT 1NP0480 - All units
This accessory conversion kit may be used to convert natural
gas (N) units for propane (LP) operation. Conversions must
be made by qualified distributor or dealer personnel.

EXTERNAL BOTTOM RETURN FILTER RACK W/FILTER Provides a cleanable, high velocity type filter and filter rack.
Attaches to the bottom of the furnace.
1BR0314 - For 14-1/2” cabinets
1BR0317 - For 17-1/2" cabinets
1BR0321 - For 21" cabinets
1BR0324 - For 24-1/2" cabinets
HIGH ALTITUDE PRESSURE SWITCHES Used to convert units for operation at altitudes from 4,500 ft.
to 10,000 ft.
Input
(MBH)
40
60
80
100
115
130

Output
(MBH)
32
48
64
80
92
104

2,000 Ft. to
5,500 Ft.
1PS0301
1PS0301
1PS0302
1PS0312
1PS0312
1PS0312

>5,500 Ft. to
0,000 Ft.
1PS0301
1PS0301
1PS0302
1PS0311
1PS0311
1PS0311

FIELD INSTALLED ACCESSORIES- ELECTRICAL
MODEL NO.

DESCRIPTION

USED WITH

2ET0770010124

THERMOSTAT-Two-stage Heat/ Cool, deluxe 24V

ALL MODELS

2TH04701024

THERMOSTAT- Two-stage Heat/Cool, Auto or manual changeover.
System Switch: Heat-Off-Cool-Auto.
Fan Switch: On-Auto.

ALL MODELS

2ET07700424

THERMOSTAT-Two-stage Heat/Cool. Programmable electronic (5+1+1),
Auto or manual changeover.
System Switch:Heat-Off-Cool-Auto. Fan Switch: Auto-On.

ALL MODELS

2TC03700124

TWINNING CONTROL

ALL MODELS

Unitary Products Group

7

NOTES

Subject to change without notice. Printed in U.S.A.
Copyright © by York International Corp. 2004. All rights reserved.

Unitary
Products
Group

036-21603-002 Rev. A (1004)
Supersedes: 036-21603-001 Rev. B (0904)

5005
York
Drive

Norman
OK
73069



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 8
Page Mode                       : UseThumbs
Page Layout                     : OneColumn
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:4d4e449b-641d-4ff4-87f6-ad3a2348f4bb
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2004:10:04 10:58:52-05:00
Create Date                     : 2004:09:30 16:17:24-05:00
Metadata Date                   : 2004:10:04 10:58:52-05:00
Document ID                     : uuid:9d7a89ee-a697-4be5-8ffa-881db76218ad
Format                          : application/pdf
Title                           : 036-21602-002-A-1004.fm
Creator                         : sardom
Author                          : sardom
EXIF Metadata provided by EXIF.tools

Navigation menu