Coleman Echelon Fc8T Users Manual 036 21602 002 A 1004
LC8T to the manual 458261b2-9ebe-42e5-a7eb-4a824ab7b896
2015-02-04
: Coleman Coleman-Echelon-Fc8T-Users-Manual-365170 coleman-echelon-fc8t-users-manual-365170 coleman pdf
Open the PDF directly: View PDF
.
Page Count: 8
| Download | |
| Open PDF In Browser | View PDF |
036-21603-002 Rev. A (1004) DESCRIPTION These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications. These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation. These units are Category I listed and may be common vented with another gas appliance as allowed by the National Fuel Gas Code. TECHNICAL GUIDE Echelon MODELS: FC8T/LC8T GAS-FIRED HIGH EFFICIENCY TWO STAGE UPFLOW/HORIZONTAL FURNACES WARRANTY STANDARD & LoNOx 20-year limited warranty on the heat exchanger. 10-year heat exchanger warranty on commercial applications. 5-year limited parts warranty. 80% AFUE FEATURES • NATURAL GAS 60 - 120 MBH INPUT • • • • • • • • • • • • • EFFICIENCY RATING CERTIFIED • This product was manufactured in a plant whose quality system is certified/registered as being in conformity with ISO 9001. • • • • Due to continuous product improvement, specifications are subject to change without notice. • • Visit us on the web at www.york.com for the most up-to-date technical information. • Additional rating information can be found at www.gamanet.org. • Two stage heating operation includes: - Two stage gas valve - Two stage inducer operation Provides increased comfort level & very quiet unit operation Adjustable delay timer allows two stage operation with single stage thermostat Compact, easy to install, ideal height 40" cabinet Blower-off delay for cooling SEER improvement. Easy to connect power/control wiring. Built-in, high level self diagnostics with fault code display. Low unit amp requirement for easy replacement application. Integrated control module for reliable, economical operation. High velocity filter and side -return filter rack provided for easy field installation. Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. Induced combustion system with inshot main burners for quiet, efficient operation. 100% shut off main gas valve for extra safety. PSC -four speed, direct drive motor with large, quiet blower. 24V, 40 VA control transformer and blower relay supplied for add-on cooling. Hi-tech tubular aluminized steel primary heat exchanger. Timed on, adjustable off blower capability for maximum comfort. Solid removable bottom panel allows easy application. Easy access from front of unit for cleaning, maintenance or service. Insulated blower compartment for quiet operation. Independent door removal for greater durability and ease of access. LoNOx models have been designed to meet specific code requirements. LoNOx models may not be converted to propane. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 036-21603-002 Rev. A (1004) D A 20 (VENT CONNECTIONS) POWER WIRING 7/8” HOLE 14-3/4 13-3/4 5-3/8 2-1/2 40 32-1/2 ACCESS WIRING 7/8” K.O. GAS INLET 1-1/4 x 2-1/2 2 14 16 2-1/4 23-1/2 8-3/4 1-1/8 30-1/8 RIGHT SIDE LEFT SIDE FRONT 1-3/8 26-3/4 C T’STAT WIRING 7/8” K.O. 5/8 20 1-1/4 5/8 D B 4” Diameter BOTTOM IMAGE RETURN END 24-3/4 TOP IMAGE SUPPLY END CABINET AND DUCT DIMENSIONS Model BTUH Output MBH CFM Cabinet Size Cabinet Dimension A B C D (F,L)C8T060A12UH11 46/34 1200 A 14 1/2 13 1/4 10 1/8 10 1/8 (F,L)C8T080A12UH11 64/48 1200 A 14 1/2 13 1/4 10 1/8 10 1/8 (F,L)C8T080B16UH11 64/48 1600 B 17 1/2 16 1/4 13 1/8 11 5/8 FC8T100B12UH11 80/53 1200 B 17 1/2 16 1/4 13 1/8 11 5/8 (F,L)C8T100C20UH11 80/53 2000 C 21 19 3/4 16 5/8 13 3/8 FC8T120C16UH11 96/64 1600 C 21 19 3/4 16 5/8 13 3/8 (F,L)C8T120C20UH11 96/64 2000 C 21 19 3/4 16 5/8 13 3/8 HORIZONTAL VENTING - MUST USE FIELDS CONTROL MODELS SWG-4Y OR TJERENLAND MODEL GPAK-JT FIELD SUPPLIED POWER VENTING KITS 2 Furnace Airflow Pipe Size High / Low Fire Inputs High / Low Fire Outputs Cabinet BTU/H BTU/H Width CFM Feet Feet 60/42 46/34 A 1200 4 4.5 34.5 80/59 64/48 A 1200 4 4.5 34.5 80/59 64/48 B 1600 4 4.5 34.5 100/65 80/53 B 1200 4 4.5 34.5 100/65 80/53 C 2000 4 4.5 34.5 120/78 96/64 C 1600 4 4.5 34.5 120/78 96/64 C 2000 4 4.5 34.5 Inches Min. Vent Length Max. Vent Length Unitary Products Group 036-21603-002 Rev. A (1004) RATINGS & PHYSICAL / ELECTRICAL DATA Output Model Cabinet Width Nominal Max. Outlet Air Temp. Air Temp. Rise AFUE MBH CFM In. (F,L)C8T060A12UH11 46/34 1200 14-1/2 (F,L)C8T080A12UH11 64/48 1200 14-1/2 80.0 30-60 175 (F,L)C8T080B16UH11 64/48 1600 17 1/2 80.0 25-55 160 80.0 °F °F 25-55 165 FC8T100B12UH11 80/53 1200 17 1/2 80.0 25-55 170 (F,L)C8T100C20UH11 80/53 2000 21 80.0 25-55 160 FC8T120C16UH11 96/64 1600 21 80.0 25-55 180 (F,L)C8T120C20UH11 96/64 2000 21 80.0 25-55 170 Output Blower Blower Size Total Unit Min. Wire one way Operation WGT. 107 MBH Hp Amps In. Amps Max Over-current Size (awg) @ 75 ft.protect (F,L)C8T060A12UH11 46/34 1/3 6.2 10 x 7 9.0 20 14 (F,L)C8T080A12UH11 64/48 1/3 6.2 10 x 7 9.0 20 14 119 (F,L)C8T080B16UH11 64/48 3/4 11.5 11 x 8 12.0 20 14 129 Model LBS FC8T100B12UH11 80/53 1/2 7.0 10 x 8 12.0 20 14 131 (F,L)C8T100C20UH11 80/53 1.0 12.2 11 x 10 14.0 20 12 149 FC8T120C16UH11 96/64 1/2 10.4 10 x 10 12.0 20 14 149 (F,L)C8T120C20UH11 96/64 1.0 12.2 11 x 10 14.0 20 12 151 Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water. FILTER SIZES Cabinet Size Side (in) Bottom (in) A 16 x 26 14 x 26 B 16 x 26 16 x 26 C (2) 16 x 26 20 x 26 D (2) 16 x 26 20 x 26 * ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil. NOTES: 1. All filters must be high velocity cleanable type. 2. Air flows above 1800 CFM require either return from two sides or one side plus bottom. Unitary Products Group 3 036-21603-002 Rev. A (1004) TABLE 1: Blower Performance CFM - Upflow (without filter) - Bottom Return Two Stage Bottom Airflow Data (SCFM) MODELS Input / CFM (F,L)C8T060A12UH11 (F,L)C8T080A12UH11 (F,L)C8T080B16UH11 FC8T100B12UH11 (F,L)C8T100C20UH11 FC8T120C16UH11 FC8T120C16UH11 Speed High Medium High Medium Low Low High Medium High Medium Low Low High Medium Low High Medium High Medium Low Low High Medium High Medium Low Low High Medium Low High Medium High Medium Low Low Ext. Static Pressure (in. H2O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1570 1410 1200 960 1590 1400 1180 940 1850 1470 1260 1700 1430 1180 950 2590 2180 1750 1450 2020 1750 1540 2500 2130 1700 1420 1490 1360 1180 960 1520 1360 1160 940 1820 1450 1260 1620 1400 1170 950 2500 2120 1720 1420 1930 1710 1500 2400 2070 1680 1390 1420 1310 1150 950 1460 1310 1130 940 1790 1440 1260 1560 1350 1160 930 2400 2040 1680 1380 1820 1650 1460 2320 1990 1650 1360 1340 1250 1100 930 1380 1260 1090 920 1750 1430 1260 1480 1300 1130 920 2280 1980 1640 1330 1730 1590 1410 2220 1920 1620 1330 1250 1190 1050 900 1300 1200 1040 880 1690 1390 1250 1390 1230 1080 880 2180 1900 1580 1300 1640 1490 1350 2110 1840 1560 1290 1180 1090 990 840 1240 1140 990 840 1630 1360 1200 1300 1160 1030 840 2080 1810 1520 1240 1540 1390 1260 2000 1760 1500 1240 1090 1020 920 800 1150 1070 920 790 1570 1310 1150 1210 1080 1000 790 1970 1720 1440 1160 1400 1290 1180 1870 1660 1410 1150 990 920 830 720 1050 960 840 710 1500 1270 1110 1110 980 860 720 1840 1600 1350 1070 1250 1160 1060 1750 1570 1320 1060 870 810 700 610 930 860 750 630 1430 1220 1070 970 870 750 620 1720 1480 1220 970 1090 1010 910 1610 1460 1210 950 700 650 580 500 800 740 640 530 1330 1150 1010 820 710 510 530 1560 1320 1060 860 920 810 750 1450 1320 1070 840 NOTES 1. Airflow expressed in standard cubic feet per minute (CFM) and in cubic meters per minute (m3/min). 2. Motor voltage at 115 V. * Input / CFM / Cabinet Width (A=14-1/2, B=17-1/2, C=21, D=24-1/2). 4 Unitary Products Group 036-21603-002 Rev. A (1004) TABLE 2: Blower Performance CFM - Upflow (without filter) - Left Side Return Two Stage Left Side Airflow Data (SCFM) MODELS Input / CFM Speed (F,L)C8T060A12UH11 (F,L)C8T080A12UH11 (F,L)C8T080B16UH11 FC8T100B12UH11 (F,L)C8T100C20UH11 FC8T120C16UH11 FC8T120C16UH11 High Medium High Medium Low Low High Medium High Medium Low Low High Medium Low High Medium High Medium Low Low High Medium High Medium Low Low High Medium Low High Medium High Medium Low Low Ext. Static Pressure (in. H2O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1770 1400 1120 880 1790 1420 1080 N/A 2000 1440 1220 1780 1430 1140 920 2770 2120 1690 1390 2160 1760 1510 2740 2120 1690 1390 1690 1380 1130 900 1720 1370 1120 900 1960 1440 1230 1710 1410 1170 940 2670 2060 1660 1370 2070 1720 1490 2650 2090 1670 1360 1630 1350 1150 900 1670 1350 1110 900 1930 1430 1230 1640 1370 1150 950 2610 2030 1630 1330 1990 1690 1470 2560 2040 1650 1330 1560 1320 1130 900 1590 1320 1100 890 1900 1420 1230 1560 1340 1120 940 2540 2000 1610 1290 1900 1630 1440 2480 2000 1610 1300 1490 1280 1120 880 1530 1280 1080 870 1800 1400 1200 1490 1280 1080 920 2450 1950 1560 1250 1800 1560 1380 2380 1940 1560 1250 1390 1230 1080 850 1450 1230 1040 850 1760 1380 1190 1390 1220 1040 890 2340 1880 1490 1200 1690 1480 1300 2280 1870 1510 1190 1290 1160 1000 790 1350 1170 1000 800 1710 1340 1170 1290 1140 970 850 2210 1810 1420 1120 1580 1390 1210 2170 1780 1440 1100 1190 1060 950 730 1260 1090 920 730 1640 1300 1160 1180 1040 890 770 2070 1720 1350 1010 1430 1250 1110 1990 1680 1310 1020 1050 930 790 660 1140 990 820 670 1550 1220 1110 1030 890 760 660 1890 1580 1240 910 1260 1080 950 1840 1550 1160 940 920 780 630 530 1000 840 690 560 1460 1150 1050 820 730 630 560 1730 1370 1070 850 1000 890 780 1650 1370 1030 840 NOTES 1. Airflow expressed in standard cubic feet per minute (CFM) and in cubic meters per minute (m3/min). 2. Return air is through side opposite motor (left side). 3. Motor voltage at 115 V. * Input / CFM / Cabinet Width (A=14-1/2, B=17-1/2, C=21, D=24-1/2). X/L C G R W2 W1 Y2 Y1 BLK BLK (HOT) WHT WHT (NEUTRAL) GRN GRN TWO-STAGE THERMOSTAT NOMINAL 120 VOLT INTEGRATED CONTROL T’STAT COMMON CONNECTION OUTDOOR UNIT Y1 Y2 Y2 W1 Y W Y C X/L W2 W1 R R Y1 SINGLE STAGE THERMOSTAT G R C G C T’STAT COMMON CONNECTION Field Wiring for Two Stage Thermostat Field Wiring for Single Stage Thermostat Unitary Products Group 5 036-21603-002 Rev. A (1004) FILTER PERFORMANCE NOTE: The filter pressure drop values in the “Filter Performance” table shown below are typical values for the type of filter listed and should only be used as a guideline. Actual pressure drop ratings for each filter type vary between filter manufacturer. The airflow capacity data published in the “Blower Performance” table listed above represents blower performance WITHOUT filters. To determine the approximate blower performance of the system, apply the filter drop value for the filter being used or select an appropriate value from the “Filter Performance” table shown below. FILTER PERFORMANCE - PRESSURE DROP INCHES W.C. CFM 0 - 750 751 - 1000 1001 - 1250 1251 - 1500 1501 - 1750 1751 - 2000 2001 & Above Filter Type Minimum Opening Size Airflow Range 1 Opening In³ 230 330 330 330 380 380 463 Disposable 2 Openings In³ 1 Opening inwc 0.01 0.05 0.1 0.1 0.15 0.19 0.19 658 658 658 WASHABLE FIBER* 2 Openings inwc 0.09 0.11 0.11 1 Opening inwc 0.01 0.05 0.1 0.1 0.14 0.18 0.18 2 Openings inwc 0.08 0.1 0.1 Pleated 1 Opening inwc 0.15 0.2 0.2 0.25 0.3 0.3 0.3 2 Openings inwc 0.17 0.17 0.17 * Washable fiber are the type supplied with furnace (if supplied). APPLYING FILTER PRESSURE DROP TO DETERMINE SYSTEM AIRFLOW To determine the approximate airflow of the unit with a filter in place, follow the steps below: 1. Select the filter type. 2. Select the number of return air openings or calculate the return opening size in square inches to determine the proper filter pressure drop. 3. Determine the External System Static Pressure (ESP) without the filter. 4. Select a filter pressure drop from the table based upon the number of return air openings or return air opening size and add to the ESP from Step 3 to determine the total system static. 5. If total system static matches a ESP value in the airflow table (i.e. 0.20 w.c. (50 Pa), 0.60 w.c. (150 Pa), etc,) the system airflow corresponds to the intersection of the ESP column and Model/Blower Speed row. 6. If the total system static falls between ESP values in the table (i.e. 0.58 w.c. (144 Pa), 0.75 w.c. (187 Pa), etc.), the static pressure may be rounded to the nearest value in the table determining the airflow using Step 5 or calculate the airflow by using the following example. Example: For a 130,000 BTUH (38.06 kW) furnace with 2 return openings and operating on high-speed blower, it is found that total system static is 0.58” w.c. To determine the system airflow, complete the following steps: Obtain the airflow values at 0.50 w.c. (125 Pa) & 0.60 w.c. (150 Pa) ESP. Airflow @ 0.50”: 2125 CFM (60.17 m3/min) Airflow @ 0.60”: 2035 CFM (57.62 m3/min) Subtract the airflow @ 0.50 w.c. (125 Pa) from the airflow @ 0.60 w.c. (150 Pa) to obtain airflow difference. 2035 - 2125 = -90 CFM (2.55 m3/min) Subtract the total system static from 0.50 w.c. (125 Pa) and divide this difference by the difference in ESP values in the table, 0.60 w.c. (150 Pa) - 0.50 w.c. (125 Pa), to obtain a percentage. (0.58 - 0.50) / (0.60 - 0.50) = 0.8 Multiply percentage by airflow difference to obtain airflow reduction. (0.8) X (-90) = -72 Subtract airflow reduction value to airflow @ 0.50 w.c. (125 Pa) to obtain actual airflow @ 0.58 inwc (144 Pa) ESP. 2125 - 72 = 2053 UNIT CLEARANCES TO COMBUSTIBLES (ALL DIMENSIONS IN INCHES) (ALL SURFACES IDENTIFIED WITH THE UNIT IN AN UPFLOW CONFIGURATION) TOP FRONT REAR LEFT SIDE RIGHT SIDE FLUE LINE CONTACT In. In. In. In. (cm) In. (cm) In. (cm) FLOOR/ BOTTOM 1 6 0 0 31 6 COMBUSTIBLE YES YES YES UPFLOW B-VENT 1 3 0 0 0 1 COMBUSTIBLE YES YES YES NO HORIZONTAL 32 6 0 1 0 6 COMBUSTIBLE NO YES YES YES3 HORIZONTAL B-VENT 0 3 0 1 0 1 COMBUSTIBLE NO YES YES YES3 APPLICATION UPFLOW 1 2 3 6 CLOSET ALCOVE ATTIC NO 14-1/2” cabinet models only. All other units “0” clearance. 14-1/2” cabinet left airflow applications only. All other units and right hand airflow applications “0” clearance. Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of the furnace jacket and building joists, studs or framing. Unitary Products Group 036-21603-002 Rev. A (1004) ACCESSORIES PROPANE (LP) CONVERSION KIT 1NP0480 - All units This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation. Conversions must be made by qualified distributor or dealer personnel. EXTERNAL BOTTOM RETURN FILTER RACK W/FILTER Provides a cleanable, high velocity type filter and filter rack. Attaches to the bottom of the furnace. 1BR0314 - For 14-1/2” cabinets 1BR0317 - For 17-1/2" cabinets 1BR0321 - For 21" cabinets 1BR0324 - For 24-1/2" cabinets HIGH ALTITUDE PRESSURE SWITCHES Used to convert units for operation at altitudes from 4,500 ft. to 10,000 ft. Input (MBH) 40 60 80 100 115 130 Output (MBH) 32 48 64 80 92 104 2,000 Ft. to 5,500 Ft. 1PS0301 1PS0301 1PS0302 1PS0312 1PS0312 1PS0312 >5,500 Ft. to 0,000 Ft. 1PS0301 1PS0301 1PS0302 1PS0311 1PS0311 1PS0311 FIELD INSTALLED ACCESSORIES- ELECTRICAL MODEL NO. DESCRIPTION USED WITH 2ET0770010124 THERMOSTAT-Two-stage Heat/ Cool, deluxe 24V ALL MODELS 2TH04701024 THERMOSTAT- Two-stage Heat/Cool, Auto or manual changeover. System Switch: Heat-Off-Cool-Auto. Fan Switch: On-Auto. ALL MODELS 2ET07700424 THERMOSTAT-Two-stage Heat/Cool. Programmable electronic (5+1+1), Auto or manual changeover. System Switch:Heat-Off-Cool-Auto. Fan Switch: Auto-On. ALL MODELS 2TC03700124 TWINNING CONTROL ALL MODELS Unitary Products Group 7 NOTES Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2004. All rights reserved. Unitary Products Group 036-21603-002 Rev. A (1004) Supersedes: 036-21603-001 Rev. B (0904) 5005 York Drive Norman OK 73069
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 8 Page Mode : UseThumbs Page Layout : OneColumn XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:4d4e449b-641d-4ff4-87f6-ad3a2348f4bb Producer : Acrobat Distiller 6.0.1 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2004:10:04 10:58:52-05:00 Create Date : 2004:09:30 16:17:24-05:00 Metadata Date : 2004:10:04 10:58:52-05:00 Document ID : uuid:9d7a89ee-a697-4be5-8ffa-881db76218ad Format : application/pdf Title : 036-21602-002-A-1004.fm Creator : sardom Author : sardomEXIF Metadata provided by EXIF.tools