Coleman Gas Fired High Efficiency Two Stage Upflow Horizontal Furnaces Fc8T Uh Users Manual 246755 YTG D 0407

Gas-Fired High Efficiency Two Stage Upflow/Horizontal Furnaces LC8T-UH 246756-CTG-C-0407

LC8T-UH to the manual 65526996-da8a-4f8e-bcb5-465a29ee965c

2015-02-04

: Coleman Coleman-Gas-Fired-High-Efficiency-Two-Stage-Upflow-Horizontal-Furnaces-Fc8T-Uh-Users-Manual-365095 coleman-gas-fired-high-efficiency-two-stage-upflow-horizontal-furnaces-fc8t-uh-users-manual-365095 coleman pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadColeman Coleman-Gas-Fired-High-Efficiency-Two-Stage-Upflow-Horizontal-Furnaces-Fc8T-Uh-Users-Manual- 246755-YTG-D-0407  Coleman-gas-fired-high-efficiency-two-stage-upflow-horizontal-furnaces-fc8t-uh-users-manual
Open PDF In BrowserView PDF
246756-CTG-C-0407

DESCRIPTION

TECHNICAL GUIDE
Echelon
MODELS: FC8T-UH/LC8T-UH
GAS-FIRED
HIGH EFFICIENCY TWO STAGE
UPFLOW/HORIZONTAL FURNACES

These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer
tubular heat exchangers. The units are factory shipped for
installation in upflow or horizontal applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage
and are also ideal for commercial applications. All units are
factory assembled, wired and tested to assure safe dependable and economical installation and operation.
These units are Category I listed and may be common
vented with another gas appliance as allowed by the
National Fuel Gas Code.

WARRANTY

STANDARD & Low NOx

20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applications.
5-year limited parts warranty.

80% AFUE

FEATURES
•

NATURAL GAS
40 - 120 MBH INPUT

•
•
•
•
•
•
•
•
•
•
•
•
EFFICIENCY
RATING
CERTIFIED

•

ISO 9001
Certified Quality
Management System

•
•
•
•

Due to continuous product improvement,
specifications are subject to change without notice.

•
•

Visit us on the web at www.york.com for the most
up-to-date technical information.

•

Additional rating information can be found at
www.gamanet.org.

•

Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
- Two speed blower operation
Provides increased comfort level & very quiet unit operation
Adjustable delay timer allows two stage operation with
single stage thermostat
Compact, easy to install, ideal height 40" cabinet
Blower-off delay for cooling SEER improvement.
Easy to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement application.
Integrated control module for reliable, economical operation.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
Induced combustion system with inshot main burners for
quiet, efficient operation.
100% shut off main gas valve for extra safety.
PSC -four speed, direct drive motor with large, quiet
blower.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Timed on, adjustable off blower capability for maximum
comfort.
Solid removable bottom panel allows easy application.
Easy access from front of unit for cleaning, maintenance
or service.
Insulated blower compartment for quiet operation.
Independent door removal for greater durability and ease
of access.
Low NOx models have been designed to meet specific
code requirements.
Low NOx models may not be converted to propane unless
screens are removed.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

246756-CTG-C-0407
B

4” Diameter
(VENT CONNECTIONS)

20

3/4

POWER WIRING
7/8” HOLE
14-3/4

13-3/4
5-3/8

2-1/2
40

32-1/2
GAS INLET
1-1/4 x 2-1/2

ACCESS
WIRING
7/8” K.O.

2

T’STAT WIRING
7/8” K.O.

14
16
23-1/2

2-1/4

8-3/4
1-1/8
30-1/8

A

LEFT SIDE

FRONT

RIGHT SIDE
5/8

1-1/2
1-1/4

26-3/4

5/8

D

C

BOTTOM IMAGE
RETURN END

20

4” Diameter

B

24-3/4

TOP IMAGE
SUPPLY END

CABINET AND DUCT DIMENSIONS
Models

CFM

Cabinet Size

FC8T040A12UH11
(F,L)C8T060A12UH11
(F,L)C8T080A12UH11
(F,L)C8T080B16UH11
(F,L)C8T080C16UH11
FC8T100B12UH11
(F,L)C8T100C20UH11
FC8T120C16UH11
(F,L)C8T120C20UH11

1200
1200
1200
1600
1600
1200
2000
1600
2000

A
A
A
B
C
B
C
C
C

Cabinet Dimension
A

B

C

D

14 1/2
14 1/2
14 1/2
17 1/2
21
17 1/2
21
21
21

13 1/4
13 1/4
13 1/4
16 1/4
19 3/4
16 1/4
19 3/4
19 3/4
19 3/4

11 1/2
11 1/2
11 1/2
14 1/2
18
14 1/2
18
18
18

10 1/8
10 1/8
10 1/8
11 5/8
13 3/8
11 5/8
13 3/8
13 3/8
13 3/8

RATINGS & PHYSICAL / ELECTRICAL DATA
Models
FC8T040A12UH11
(F,L)C8T060A12UH11
(F,L)C8T080A12UH11
(F,L)C8T080B16UH11
(F,L)C8T080C16UH11
FC8T100B12UH11
(F,L)C8T100C20UH11
FC8T120C16UH11
(F,L)C8T120C20UH11

Models
FC8T040A12UH11
(F,L)C8T060A12UH11
(F,L)C8T080A12UH11
(F,L)C8T080B16UH11
(F,L)C8T080C16UH11
FC8T100B12UH11
(F,L)C8T100C20UH11
FC8T120C16UH11
(F,L)C8T120C20UH11

Blower
Input/Cabinet Output BTU/H
Nominal
Cabinet Width
Blower
Size
High/Low
High/Low
Airflow
AFUE
MBH
MBH
CFM
In
Hp
Amps
In
40/26
32/21
1200
14-1/2
80.0
1/2
7.7
10 x 8
57/42
46/34
1200
14-1/2
80.0
1/2
7.7
10 x 8
80/59
64/48
1200
14 1/2
80.0
1/2
7.7
10 x 8
80/59
64/48
1600
17-1/2
80.0
3/4
11.5
10 x 10
80/59
64/48
1600
21
80.0
3/4
11.5
10 x 10
100/65
80/53
1200
17 1/2
80.0
1/2
11.5
10 x 10
100/65
80/53
2000
21
80.0
1
14
11 x 10
120/78
96/64
1600
21
80.0
3/4
11.5
11 x 10
120/78
96/64
2000
21
80.0
1
14
11 x 11
Input/Cabinet Max. Outlet
Low Fire
High Fire
Min. wire Size Operation
Max
Unit
Weight
High/Low
Air Temp
Air Temp. Rise Air Temp. Rise
Over-Current (awg) @ 75 ft
Amps
one way
Protect
MBH
°F
°F
°F
Lbs
40/26
150
15-45
20-50
9.0
20
14
107
57/42
160
25-55
35-65
9.0
20
14
107
80/52
175
30-60
40-70
9.0
20
14
117
80/59
160
25-55
25-55
12.0
20
14
129
80/59
160
25-55
25-55
12.0
20
14
130
100/65
170
25-55
40-70
12.0
20
14
128
100/65
170
25-55
40-70
12.0
20
14
145
120/78
180
25-55
45-75
12.0
20
14
145
120/78
170
25-55
35-65
14.0
20
12
147

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.

2

Unitary Products Group

246756-CTG-C-0407
BLOWER PERFORMANCE CFM - UPFLOW (WITHOUT FILTER) - BOTTOM RETURN
Bottom Airflow Data (SCFM)
Models

Speed

FC8T040A12UH11

(F,L)C8T060A12UH11

(F,L)C8T080A12UH11

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1540

1460

1360

1290

1200

1110

1020

900

760

Medium High

1430

1390

1330

1250

1190

1110

1030

940

840

710

Medium Low

1200

1180

1140

1100

1050

1000

930

850

750

620

980

980

960

920

890

840

790

720

620

530

1570

1490

1420

1340

1250

1180

1090

990

870

700

Medium High

1410

1360

1310

1250

1190

1090

1020

920

810

650

Medium Low

1200

1180

1150

1100

1050

990

920

830

700

580

Low

960

960

950

930

900

840

800

720

610

500

High

1590

1520

1460

1380

1300

1240

1150

1050

930

800

Medium High

1400

1360

1310

1260

1200

1140

1070

960

860

740

Medium Low

1180

1160

1130

1090

1040

990

920

840

750

640

Low

940

940

940

920

880

840

790

710

630

530

High

1850

1820

1790

1750

1690

1630

1570

1500

1430

1330

Medium

1470

1450

1440

1430

1390

1360

1310

1270

1220

1150

Low

1260

1260

1260

1260

1250

1200

1150

1110

1070

1010

High

2077

1992

1922

1830

1727

1617

1507

1355

1219

1050

Medium

1729

1673

1631

1581

1507

1421

1293

1187

1053

907

Low

1448

1452

1432

1390

1324

1264

1176

1058

939

774

High

1700

1620

1560

1480

1390

1300

1210

1110

970

820

Medium High

1430

1400

1350

1300

1230

1160

1080

980

870

710

Medium Low

1180

1170

1160

1130

1080

1030

1000

860

750

510

Low

950

950

930

920

880

840

790

720

620

530

High

2590

2500

2400

2280

2180

2080

1970

1840

1720

1560

Medium High

2180

2120

2040

1980

1900

1810

1720

1600

1480

1320

Medium Low

1750

1720

1680

1640

1580

1520

1440

1350

1220

1060

Low

1450

1420

1380

1330

1300

1240

1160

1070

970

860

High

2020

1930

1820

1730

1640

1540

1400

1250

1090

920

Medium

1750

1710

1650

1590

1490

1390

1290

1160

1010

810

Low

1540

1500

1460

1410

1350

1260

1180

1060

910

750

High

2500

2400

2320

2220

2110

2000

1870

1750

1610

1450

Medium High

2130

2070

1990

1920

1840

1760

1660

1570

1460

1320

Medium Low

1700

1680

1650

1620

1560

1500

1410

1320

1210

1070

Low

1420

1390

1360

1330

1290

1240

1150

1060

950

840

FC8T120C16UH11

(F,L)C8T120C20UH11

0.2

1610

Low

(F,L)C8T080C16UH11

(F,L)C8T100C20UH11

0.1
High

High

(F,L)C8T080B16UH11

FC8T100B12UH11

Ext. Static Pressure (in. H2O)

NOTES:

1. Airflow expressed in standard cubic feet per minute.
2. Motor voltage at 115 V.

Unitary Products Group

3

246756-CTG-C-0407
BLOWER PERFORMANCE CFM - UPFLOW (WITHOUT FILTER) - LEFT SIDE RETURN
Left Side Airflow Data (SCFM)
Models

Speed

FC8T040A12UH11

(F,L)C8T060A12UH11

(F,L)C8T080A12UH11

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1730

1660

1570

1480

1390

1300

1200

1090

930

Medium High

1390

1390

1350

1320

1270

1210

1150

1080

970

790

Medium Low

1120

1120

1120

1110

1080

1080

1020

930

830

690

Low

880

910

920

920

910

870

820

740

650

510

1770

1690

1630

1560

1490

1390

1290

1190

1050

920

1400

1380

1350

1320

1280

1230

1160

1060

930

780

Medium Low

1120

1130

1150

1130

1120

1080

1000

950

790

630

Low

880

900

900

900

880

850

790

730

660

530
1000

High

1790

1720

1670

1590

1530

1450

1350

1260

1140

Medium High

1420

1370

1350

1320

1280

1230

1170

1090

990

840

Medium Low

1080

1120

1110

1100

1080

1040

1000

920

820

690

Low

N/A

900

900

890

870

850

800

730

670

560
1460

High

2000

1960

1930

1900

1800

1760

1710

1640

1550

Medium

1440

1440

1430

1420

1400

1380

1340

1300

1220

1150

Low

1220

1230

1230

1230

1200

1190

1170

1160

1110

1050

High

2172

2101

2028

1943

1854

1732

1621

1503

1344

1144

Medium

1640

1633

1626

1584

1518

1480

1378

1276

1125

965

Low

1388

1404

1412

1396

1362

1311

1222

1144

1001

827

High

1780

1710

1640

1560

1490

1390

1290

1180

1030

820

Medium High

1430

1410

1370

1340

1280

1220

1140

1040

890

730

Medium Low

1140

1170

1150

1120

1080

1040

970

890

760

630

Low

920

940

950

940

920

890

850

770

660

560

High

2770

2670

2610

2540

2450

2340

2210

2070

1890

1730

Medium High

2120

2060

2030

2000

1950

1880

1810

1720

1580

1370

Medium Low

1690

1660

1630

1610

1560

1490

1420

1350

1240

1070

Low

1390

1370

1330

1290

1250

1200

1120

1010

910

850

High

2160

2070

1990

1900

1800

1690

1580

1430

1260

1000

Medium

1760

1720

1690

1630

1560

1480

1390

1250

1080

890

FC8T120C16UH11

(F,L)C8T120C20UH11

0.2

1810

High

(F,L)C8T080C16UH11

(F,L)C8T100C20UH11

0.1
High

Medium High

(F,L)C8T080B16UH11

FC8T100B12UH11

Ext. Static Pressure (in. H2O)

Low

1510

1490

1470

1440

1380

1300

1210

1110

950

780

High

2740

2650

2560

2480

2380

2280

2170

1990

1840

1650

Medium High

2120

2090

2040

2000

1940

1870

1780

1680

1550

1370

Medium Low

1690

1670

1650

1610

1560

1510

1440

1310

1160

1030

Low

1390

1360

1330

1300

1250

1190

1100

1020

940

840

NOTES:

1. Airflow expressed in standard cubic feet per minute.
2. Return air is through side opposite motor (left side).
3. Motor voltage at 115 V.
4. Airflow through motor side return (right side) maybe slightly less than shown above.

4

Unitary Products Group

246756-CTG-C-0407

HORIZONTAL SIDEWALL VENTING
For applications where vertical venting is not possible, the
only approved method of horizontal venting is the use of an
auxiliary power vent. Approved power venters are Fields
Controls Model SWG-4Y or the appropriate Tjernlund GPAK
model. Follow all application and installation details provided
by the manufacturer of the power vent. This unit may be horizontally vented using 4” (10.2 cm) diameter pipe with a minimum length of 4.5 feet (1.37 m) and a maximum length of
34.5 feet (10.82 m) with up to 4 elbows.

NOTE: The filter pressure drop values in the “Filter Performance” table shown below are typical values for the type of
filter listed and should only be used as a guideline. Actual
pressure drop ratings for each filter type vary between filter
manufacturer.
RECOMMENDED FILTER SIZES
Cabinet Size

Side (in)

Bottom (in)

A

16 x 25

14 x 25

B

16 x 25

16 x 25

C

(2) 16 x 25

20 x 25

FILTER PERFORMANCE
The airflow capacity data published in the “Blower Performance” table listed above represents blower performance
WITHOUT filters. To determine the approximate blower performance of the system, apply the filter drop value for the filter being used or select an appropriate value from the “Filter
Performance” table shown below.

NOTES:
1. Air velocity through throwaway type filters may not exceed 300
feet per minute. All velocities over this require the use of high
velocity filters.
2. Air flows above 1800 CFM require either return from two sides or
one side plus bottom.

FILTER PERFORMANCE - PRESSURE DROP INCHES W.C. AND (KPA)
Airflow Range

Filter Type

Minimum
Opening Size

Disposable

Washable Fiber

Pleated

in2

In W.C.

In W.C.

In W.C.
0.15

CFM
0 - 750

230

0.01

0.01

751 - 1000

330

0.05

0.05

0.20

1001 - 1250

330

0.10

0.10

0.20

1251 - 1500

330

0.10

0.10

0.25

1501 - 1750

380

0.15

0.14

0.30

1751 - 2000

380

0.19

0.18

0.30

2001 & Above

463

0.19

0.18

0.30

UNIT CLEARANCES TO COMBUSTIBLES (ALL DIMENSIONS IN INCHES, AND ALL SURFACES IDENTIFIED WITH THE
UNIT IN AN UPFLOW CONFIGURATION)
Application

Top

Front

Rear

Left
Side

Right
Side

Flue

Floor/
Bottom

Closet

Alcove

Attic

Line
Contact

Upflow

1

6

0

0

3

6

Combustible

Yes

Yes

Yes

No

Upflow B-Vent

1

3

0

0

0

1

Combustible

Yes

Yes

Yes

No

Horizontal

1

6

0

0

3

6

Combustible

No

Yes

Yes

Yes1

Horizontal B-Vent

1

3

0

0

0

1

Combustible

No

Yes

Yes

Yes1

1

Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal postion) of the furance jacket
and building joists, studs or framing.

Unitary Products Group

5

246756-CTG-C-0407

APPLYING FILTER PRESSURE DROP TO
DETERMINE SYSTEM AIRFLOW
To determine the approximate airflow of the unit with a filter in
place, follow the steps below:
1.
2.

Select the filter type.
Select the number of return air openings or calculate the
return opening size in square inches to determine the
proper filter pressure drop.
3. Determine the External System Static Pressure (ESP)
without the filter.
4. Select a filter pressure drop from the table based upon
the number of return air openings or return air opening
size and add to the ESP from Step 3 to determine the
total system static.
5. If total system static matches a ESP value in the airflow
table (i.e. 0.20 w.c. (50 Pa), 0.60 w.c. (150 Pa), etc,) the
system airflow corresponds to the intersection of the
ESP column and Model/Blower Speed row.
6. If the total system static falls between ESP values in the
table (i.e. 0.58 w.c. (144 Pa), 0.75 w.c. (187 Pa), etc.),
the static pressure may be rounded to the nearest value
in the table determining the airflow using Step 5 or calculate the airflow by using the following example.
Example: For a 60,000 BTUH (17.58 kW) furnace with a bottom return opening and operating on high-speed blower, it is
found that total system static is 0.58” w.c. To determine the
system airflow, complete the following steps:
Obtain the airflow values at 0.50 w.c. (125 Pa) & 0.60 w.c.
(150 Pa) ESP.
Airflow @ 0.50”: 1250 CFM (35.4 m3/min)
Airflow @ 0.60”: 1180 CFM (33.4 m3/min)
Subtract the airflow @ 0.50 w.c. (125 Pa) from the airflow @
0.60 w.c. (150 Pa) to obtain airflow difference.
1180 - 1250 = -70 CFM (-12 m3/min)
Subtract the total system static from 0.50 w.c. (125 Pa) and
divide this difference by the difference in ESP values in the
table, 0.60 w.c.
(150 Pa) - 0.50 w.c. (125 Pa), to obtain a
percentage.

ACCESSORIES
PROPANE (LP) CONVERSION KIT 1NP0347 - All units
This accessory conversion kit may be used to convert natural
gas (N) units for propane (LP) operation. Conversions must
be made by qualified distributor or dealer personnel.
SIDE RETURN FILTER 1SR0302 - All Models
1SR0200 - All Models
BOTTOM RETURN FILTER 1BR0114 or 1BR0214 - For 14-1/2” cabinets
1BR0117 or 1BR0217 - For 17-1/2” cabinets
1BR0121 or 1BR0221 - For 21” cabinets
1BR0124 or 1BR0224 - For 24-1/2” cabinets
INTERNAL FILTER WITH FIBER FILTER 1HF0801 - All Models
HIGH ALTITUDE PRESSURE SWITCHES For installation where the altitude is less than 8,000 feet it is
not required that the pressure switch be changed. For altitudes above 8,000 feet see kits below. Conversion must be
made by qualified distributor or dealer personnel.
1PS0313 - 040, 060, 080, 100 MBH
1PS0314 - 120 MBH
ROOM THERMOSTATS - A wide selection of compatible
thermosets are available to provide optimum performance
and features for any installation.
1 Heat Stage only, manual, mechanical thermostat. Add subbase for 1H/1C.
1H/1C, manual change-over electronic non-programmable
thermostat.
1H/1C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.
1H/1C, auto/manual changeover, electronic programmable.
* For the most current accessory information, refer to the
price book or consult factory.

(0.58 - 0.50) / (0.60 - 0.50) = 0.8
Multiply percentage by airflow difference to obtain airflow
reduction.
(0.8) X (-70) = -56
Subtract airflow reduction value to airflow @ 0.50 w.c. (125
Pa) to obtain actual airflow @ 0.58 in. w.c. (144 Pa) ESP.
1250 - 56 = 1194

6

Unitary Products Group

Unitary Products Group
Thermostat Installer Setup
Number 0170 - System Type must be set to 8 - 2 Heat/2 Cool
Multistage Conventional

Thermostat Installer Setup
Number 1 - System Type must be set to 6 2 Heat/2 Cool Conventional

Thermostat Installer Setup
Number 15 - Compressor
Protection - must be set to 5

Connection of the "C" Termainal,
24-Volt Common, is optional
when used with batteries

Connection of the "C" Termainal,
24-Volt Common, is optional
when used with batteries

Step 1 of Thermostat User
Configuration Menu must be
set to MS 2

Connection of the "C"
Termainal, 24-Volt Common,
is optional when used with
batteries

G
Fan

G
Fan

Connection of the "C"
Termainal, 24-Volt Common,
is optional when used with
batteries

W2
Second Stage Heat

W2
Second Stage Heat
G
Fan

E/W1
First Stage Heat

E/W1
First Stage Heat

G
Fan

RC
24-Volt Hot (Cool XFMR)

RC
24-Volt Hot (Cool XFMR)

R
24-Volt Hot

W2
Second Stage Heat

R
24-Volt Hot

R
24-Volt Hot (Heat XFMR)

R
24-Volt Hot (Heat XFMR)

Y2
Second Stage Cool

W2
Second Stage Heat

Y2
Second Stage Cool

Y2
Second Stage Cool

Y2
Second Stage Cool

Y1
First Stage Cool

E/W1
First Stage Heat

Y
First Stage Cool

Y
First Stage Cool

Y
First Stage Cool

C
24-Volt Common

W
First Stage Heat

C
24-Volt Common

C
24-Volt Common

Step 16 of Thermostat User
Configuration Menu must be set
to ON to use Comfort Alert
Features

Step 1 of Thermostat User
Configuration Menu must be set
to MLTI STG

HM
Humidistat

L
Malfunction Light

G
Fan

W2
Second Stage Heat

E/W1
First Stage Heat

R
24-Volt Hot

Y2
Second Stage Cool

Y1
First Stage Cool

C
24-Volt Common

*PP32U72124

*PP32U71124

*DP22U70124

C
24-Volt Common

THERMOSTAT

THERMOSTAT

*PP32U70124

*DN22U00124

*DN22C00124

THERMOSTAT

THERMOSTAT

THERMOSTAT

AC9 2 Stage Scroll A/C w/2 Stage Furnace, 2 Stage Cooling Ready- PT8/9; (F,L)*8/9T, (G,L)*8/9T, XYG8S-U, XYF8S-U / XYF8S-U*L

G
Fan

W2
Second Stage Heat

W/W1
Single/First Stage Heat

Y1
First Stage Cool
Y/Y2
Single/Second Stage
Cool
R
24-Volt Hot

C
24-Volt Common

2 STAGE PSC
FURNACE CONTROL

24V HUMIDIFIER
(Optional)

Comfort Alert
Interface

R
24-Volt Hot

Y2
Second Stage Cool

Y1
First Stage Cool

C
24-Volt Common

TWO STAGE
AIR CONDITIONING

246756-CTG-C-0407

For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at
www.upgnet.com in the Product Catalog Section.

Thermostat Chart - AC

7

Thermostat Chart - HP

Subject to change without notice. Printed in U.S.A.
Copyright © by York International Corp. 2007. All rights reserved.

Unitary
Products
Group

246756-CTG-C-0407
Supersedes: 246756-CTG-B-0806

5005
York
Drive

Norman
OK
73069

HP23

Thermostat Installer Setup Number 0210 External Fossil Fuel Kit - must be set to 0 External Fossil Fuel Kit is Controlling
Heat Pump Backup Heat

Thermostat Installer Setup Number 0200
- Backup Heat Source - must be set to 1 - Heat
Pump Backup Heat Source is Fossil Fuel

Step 1 of Thermostat User
Configuration Menu must be
set to Heat Pump 2

W2
Second Stage Auxiliary Heat

Thermostat Installer Setup Number 0190 Reversing Valve (O/B) Operation - must be set to 0
- O/B Terminal Energized in Cooling

E/W1
First Stage Auxiliary Heat

AUX
Auxiliary Heat

Selection of GAS/ELEC switch on
thermostat not necessary

W2
Second Stage Auxiliary Heat

Y2
Second Stage Heat/Cool

Y2
Second Stage Heat/Cool

Thermostat Installer Setup Number 0170
- System Type - must be set to
12 - 3 Heat/2 Cool Heat Pump

E/W1
First Stage Auxiliary Heat

L
Malfunction Light

L
Malfunction Light

Step 1 of Thermostat User Configuration
Menu must be set to Heat Pump 2

HM
Humidistat

Y2
Second Stage Heat/Cool

L
Malfunction Light

O
Reversing Valve–Energized in Cool

O
Reversing Valve–Energized in Cool

O/B
Reversing Valve

G
Fan

G
Fan

DHM
Dehumidistat
G
Fan

E
Emergency Heat

R
24-Volt Hot

Y1
First Stage Heat/Cool

Y1
First Stage Cool

C
24-Volt Common

Set W2 Delay on furnace to OFF

24V HUMIDIFIER
(Optional)

Bonnet Sensor
(Optional)

G
Fan

W2
Second Stage Heat

W/W1
Single/First Stage Heat

R
24-Volt Hot

R
24-Volt Hot

Y1
First Stage Heat/Cool

Y
First Stage Heat/Cool

C
24-Volt Common

*PP32U72124

PSC-2 STAGE
COOLING READY
FURNACE CONTROL

R
24-Volt Hot (Heat XFMR)

C
24-Volt Common

C
24-Volt Common

*PP32U71124

THERMOSTAT

Y/Y2
Single/Second Stage Cool

*DN22H00124
*DP22U70124

*PP32U70124

RC
24-Volt Hot (Cool XFMR)

THERMOSTAT

THERMOSTAT

Two Stage H/P - H*5B, YZE - w/Two Stage Furnace, 2 Stage Cooling Ready - PT8/9, (F,L)*8/9T, (G,L)*8/9T, XYG8S-U, XYF8S-U / XYF8S-U*L
W/031-01996- Series Demand Control; Hot Heat Pump Mode OR Conventional

Change FFuel Jumper on
Heat Pump to ON

BS
Bonnet Sensor

BSG
Bonnet Sensor

W
Auxiliary Heat

Y2
Second Stage Heat/Cool

X/L
Malfunction Light

O
Reversing Valve–Energized in Cool

W2 OUT
Second Stage Auxiliary Heat Output

W1 OUT
First Stage Auxiliary Heat Output

R
24-Volt Hot

Y2 OUT
Second Stage Cool Output

Y1
First Stage Heat/Cool

C
24-Volt Common

TWO STAGE
HEAT PUMP



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Mode                       : UseThumbs
XMP Toolkit                     : 3.1-702
About                           : uuid:d353b3e6-4632-4335-98c5-d95a70eee782
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2007:04:25 15:28:39-05:00
Create Date                     : 2007:04:18 09:41:21-05:00
Metadata Date                   : 2007:04:25 15:28:39-05:00
Document ID                     : uuid:537861fb-89f9-4a15-afd4-6dd2cd216528
Instance ID                     : uuid:a29a4757-fdc4-40c2-b8b6-cbd1c6b7a2f6
Format                          : application/pdf
Title                           : 246755-YTG-D-0407.fm
Creator                         : csardom
Page Count                      : 8
Page Layout                     : OneColumn
Author                          : csardom
EXIF Metadata provided by EXIF.tools

Navigation menu