Communication Components CE-1819-10G2 PCS Multi-Channel Cell Extender User Manual

Communication Components Inc PCS Multi-Channel Cell Extender

a href="https://usermanual.wiki/Communication-Components" itemprop="url"> Communication Components >

User manual

100141-INST  Cell Extender Model CE-1819-10G2    Page 1 of 5  Rev. - 05/2007  User Manual and Installation Instructions            CELL EXTENDER CE-1819-10G2 USER MANUAL AND INSTALLATION INSTRUCTIONS      INSTALLATION OPTIONS CCI’s Cell Extender product family is easy to install, requires no maintenance, and is fully compatible with the Original Equipment Manufacturer’s (OEM) Base Station equipment.  The Cell Extender offers the maximum installation flexibility by allowing the BTS to be physically distanced from the antenna and mounting structure.  As such, the need to run both a T1 connection and an AC connection on the mounting structure is eliminated.  Three installation options are available:   • Configuration 1 - The CE-1819-10G2 can be mounted on the same mounting structure next to the Micro Base Station.  This option is ideal when an existing micro-BTS site is being upgraded with a Cell Extender or when both AC and T1 connections are available on the mounting structure.    • Configuration 2 - The BTS equipment is installed at ground level (or indoors) and the Cell Extender is mounted on the mounting structure, in close proximity to the antenna.  This configuration is ideal for environments where AC lines and T1-connections are not easily available on the mounting structure or when it is desired to keep the BTS equipment at ground level.  For this configuration, the Cell Extender should be ordered with the Remote Power Option (Option 3) which includes a Bias-T and Remote Power Supply module to provide DC power to the Cell Extender over the Coax cable.  • Configuration 3 - Both the BTS and the Cell Extender equipment are installed at the ground level or indoors.  This is intended for applications where it is impractical to install any equipment other than the antenna on the mounting structure.     MOUNTING INSTRUCTIONS The CE-1819-10G2 can be either pole mounted or wall mounted.  It is delivered with a Pole Mounting Kit to allow it to be secured to a pole structure.   A separate document titled Mounting Instructions – Outdoor Cell Extender (100141-MNT) is included which provides detailed mounting instructions.   COMMUNICATION COMPONENTS INC Extending Wireless Coverage 89 Leuning Street  Phone:  201-342-3338 2nd Floor  Fax:     201-342-3339 South Hackensack, NJ 07606 www.cciproducts.com
100141-INST  Cell Extender Model CE-1819-10G2    Page 2 of 5  Rev. - 05/2007  User Manual and Installation Instructions     Diagram 1 – Side view of Cell Extender with Pole Mounting Brackets Installed    CONNECTING THE CELL EXTENDER TO THE BTS EQUIPMENT The Cell Extender sits between the BTS equipment and the Antennas.  The 7/16” DIN connector labeled “FEEDER A (TX/RX)” is connected via a coax feeder line to the TX/RX output of the BTS.  The connector labeled “Antenna A (TX/RX)” is then connected to the actual Antenna.  For BTS equipment with receive diversity and Cell Extenders with Option 1 – Receive Diversity, the 7/16” DIN connector labeled “FEEDER B (Rx only)” is connected to the “RX” input of the BTS equipment.  Likewise, the connector labeled “ANTENNA B (Rx only)” is then connected to the diversity Antenna.    POWERING THE CELL EXTENDER The Cell Extender can be ordered with three separate power options:  Direct AC (default),  Remote Power (Option 3), or Direct DC power (Option 5/6).  With Direct AC, the Cell Extender is supplied with a power cord that is plugged into a 110VAC or 220VAC power source.  With the Remote Power option, a remote power module (see Diagram 2) supplies the necessary voltage to the Cell Extender over the coax cable.  The Direct DC power option is for applications where a solar power source or battery voltage is being used to power the unit.  Two direct DC voltages are supported: 24-30VDC and 36-72VDC.  With the Direct AC and Direct DC options, the Cell Extender is provided with a hermetically sealed connector and a power cable that contains three wires – black, white and green.  The pinouts are defined below:  AC/DC Input cable  Wire Color  Pin #  Direct AC   Direct 24VDC  Direct 48VDC Black  PIN C  Line (hot)  No Connection  No Connection White   PIN A  Neutral   +24-30 VDC  +36-72VDC Green  PIN B  Chassis Ground  DC Return  DC Return
Download:
Mirror Download [FCC.gov]
Document ID811836
Application ID1jvC9zIMnl7hyWie5MzMDw==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize18.33kB (229128 bits)
Date Submitted2007-07-04 00:00:00
Date Available2007-07-04 00:00:00
Creation Date2007-06-21 16:06:38
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2007-06-21 16:06:38
Document TitleMicrosoft Word - Cell Extender CE-1819-10G2 Installation Instructions.doc
Document CreatorPScript5.dll Version 5.2
Document Author: johnm
FCC ID Filing: NT3CE-1819-10G2

Navigation menu