Communication Components CE-1819-125MC PCS Band Multi Carrier Cell Extender User Manual Authority to Act as Agent to a TCB
Communication Components Inc PCS Band Multi Carrier Cell Extender Authority to Act as Agent to a TCB
User Manual
Communication Components, Inc. 89 Leuning Street South Hackensack, NJ 07606 Phone: 201-342-3338 Fax: 201-342-3339 PCS Band Multi Carrier Cell Extender CCI Model Number CE-1819-125MC-XXXX USER’S GUIDE Product Description: Communication Components, Inc. PCS CDMA Multi-carrier Cell Extender improves the performance of CDMA Base Stations (BTS) in indoor and outdoor locations, allowing for cost efficient implementation of high capacity radio networks. By increasing both the downlink power and receive sensitivity, CCI’s Cell Extender increases the overall coverage area and improves the performance of the site. Operation Description: CCI’s Multi-channel CDMA Cell Extender is designed to improve overall site performance by boosting both forward and reverse link parameters in a balanced manner. The system is designed to provide 125 Watts of usable CDMA output power per sector antenna (63 W per sector antenna for Canada) and can serve up to three sectors with two feeder antennas per sector. As such, a CE-1819125MC system used in six-carrier sector with 3 carriers per antenna can delivers 40 W per carrier (21 W per carrier for Canada). • CCI supplies Cell Extender cabinet that requires a dual 30A 208/240V breaker and two batteries for backup purposes. RF Connection Cell Extender cabinet must be bolted to the frame. • Connect Cell Extender input Tx/Rx and Rx ports (connectors type N located on the connectors plate inside of the main cabinet) with DO and D1 ports of BTS in the proper sector using two DIN-N jumpers. • Connect Cell Extender output Tx/Rx and Rx ports (Bias-T blocks with DIN connectors located on the connectors plate inside of the main cabinet) with Tx/Rx and Rx ports of Main Lines of the proper sector using two DIN-DIN jumpers. AC Connection • 20A Breakers must be installed in the main electrical box (or A-box). • 3-conductor AC-wire gage 12-14 must be run through metal conduit to the electrical junction box inside of the CCI Cell Extender cabinet. The entry point to this junction box is from the bottom of the cabinet via a corrugated shield. • Run a standard 6 gauge grounding wire from the site’s main grounding bar (Bus-bar in the A-box) to the CCI Cell Extender cabinet and secure it to the electrical junction box inside the cabinet. • Run Alarm cable through 1” conduit to the alarm card in BTS. Site technician will make actual connection. • Install the batteries: a. Place the batteries in the bottom of the cabinet b. Use the short jumper to connect the positive terminal of one battery to the negative terminal of the other battery. c. Cover the battery terminals with the supplied terminal boots. • Confirm proper electrical connection a. Turn off all breakers on PSU modules located in the Cell Extender cabinet; b. Turn on breakers in the main electrical box (A-box) c. Confirm that the green Power LED on PSU’s turn on. Setting the RF Output Power on the CE-1819-125MC-XXXxX Cell Extender The RF output power is adjustable on the Cell Extender. Use Gain Control Block that contains a set of the input signal attenuators. The user must adjust the RF input power to the Cell Extender connecting the proper pad such that the combined RF output power level of any number of the individual carriers does not exceed the levels shown below in order for the RF output spectral emissions to be compliant with the FCC spurious emissions limit of -13 dBm outside of the assigned frequency block. These levels must not exceed Channel Center Frequency (MHz) 1930-1990 Maximum RF 0utput (Watt)* 125 Maximum RF 0utput for Canada (Watt) 63 This equipment complies with Part 24 of the FCC rules. Any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. In order to comply with FCC rules for RF exposure, it must be observed that the antenna connected to this equipment be fixed on an outdoor structure and that it must have a minimum separation distance of 10 meters between it and any person. In accordance with Industry Canada RSS-131, the manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. PCS block filters must be installed to achieve compliance with part 24 spurious emission limits. Filters are manufactured by Clearcomm Technologies, part number CCFA-174XX . Connect the output filter port marked “BTS “ with the port on By-Pass module marked “To BTS Duplexer”. Connect the filter port marked “ANT” to the By-Pass module port marked “ From ANT Duplexer”. Connect the filter port marked “AMP OUT” with corresponding attenuator port on Gain Control module. Connect filter port marked “AMP IN” to the Amplifier module port marked “ RF OUT”. * Reverse Link Forward Link PCS Operating Range 1850-1910MHz 1930-1990 MHz Nominal 20 dB Bandwidth 60 MHz 39.27 MHz PCS band specific filters AD, BE, FC AD, BE, FC Nominal Pass-Band Gain 12 dB max Adjustable to 13.94 dB max System Noise Figure: 1.5.0 dB Max. System Group Delay: 180 nanosecond Max Pass Band Ripple: +/-0.5 dB Max. Output Third Order IM3 @ 1.98 MHz 0ffset: -55 dBc/30 kHz 1 dB Compression Point: +15 dBm Min. +58.5 dBm Typ. Input /Output VSWR: 1.5:1 Max. 1.5:1 Max. Up-Link-Down-Link Isolation 80 dB By-Pass Insertion Loss 0.5 dB for ground level unit, 0.3 dB for tower top unit Nominal Mean Output Power: 125 W ; 63 W for Canada Input and Output Impedance 50 Ohm Power Supply Voltage: 220 VAC Power Consumption: 1.0 KW Max per sector Dimensions 12”L x 5.5” W x 3”D -tower unit 77”H x 24”W x 21”D - ground level unit Enclosure NEMA 3R Weather Proof Cabinet Connectors Input from BTS –type N, F; output to hard lines -7 /16 DIN, F; TTA—7/16 DIN, F Weight TTA –10 Lbs, GLU –100 Lbs for one sector Mounting TTA –antenna pipe, GLU - concrete pad, 2.5’x2.5’ area Operating Temperature: -25° to +50° C Ambient * With External Tower Mounted Amplifier
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Modify Date : 2007:05:03 16:14:31-03:00 Create Date : 2007:05:03 16:14:18-04:00 Page Count : 4 Creation Date : 2007:05:03 20:14:18Z Mod Date : 2007:05:03 20:14:18Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : RUBY DULMAGE Metadata Date : 2007:05:03 20:14:18Z Creator : RUBY DULMAGE Title : Authority to Act as Agent to a TCB: Page Mode : UseNone Tagged PDF : YesEXIF Metadata provided by EXIF.tools