Communication Components CE-1819-125MC PCS Band Multi Carrier Cell Extender User Manual Authority to Act as Agent to a TCB

Communication Components Inc PCS Band Multi Carrier Cell Extender Authority to Act as Agent to a TCB

User Manual

Download: Communication Components CE-1819-125MC PCS Band Multi Carrier Cell Extender User Manual Authority to Act as Agent to a TCB
Mirror Download [FCC.gov]Communication Components CE-1819-125MC PCS Band Multi Carrier Cell Extender User Manual Authority to Act as Agent to a TCB
Document ID789403
Application IDqiqCdmNpUdvd0wgPvGMzhA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize18.13kB (226673 bits)
Date Submitted2007-05-07 00:00:00
Date Available2007-05-08 00:00:00
Creation Date2007-05-03 16:14:18
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2007-05-03 16:14:31
Document TitleAuthority to Act as Agent to a TCB:
Document CreatorAcrobat PDFMaker 5.0 for Word
Document Author: RUBY DULMAGE

Communication Components, Inc.
89 Leuning Street
South Hackensack, NJ 07606
Phone: 201-342-3338
Fax:
201-342-3339
PCS Band Multi Carrier Cell Extender
CCI Model Number CE-1819-125MC-XXXX
USER’S GUIDE
Product Description:
Communication Components, Inc. PCS CDMA Multi-carrier Cell Extender
improves the performance of CDMA Base Stations (BTS) in indoor and outdoor
locations, allowing for cost efficient implementation of high capacity radio
networks.
By increasing both the downlink power and receive sensitivity, CCI’s Cell
Extender increases the overall coverage area and improves the performance of
the site.
Operation Description:
CCI’s Multi-channel CDMA Cell Extender is designed to improve overall site
performance by boosting both forward and reverse link parameters in a balanced
manner. The system is designed to provide 125 Watts of usable CDMA output
power per sector antenna (63 W per sector antenna for Canada) and can serve
up to three sectors with two feeder antennas per sector. As such, a CE-1819125MC system used in six-carrier sector with 3 carriers per antenna can delivers
40 W per carrier (21 W per carrier for Canada).
• CCI supplies Cell Extender cabinet that requires a dual 30A 208/240V breaker
and two batteries for backup purposes.
RF Connection
Cell Extender cabinet must be bolted to the frame.
• Connect Cell Extender input Tx/Rx and Rx ports (connectors type N located on
the connectors plate inside of the main cabinet) with DO and D1 ports of BTS in
the proper sector using two DIN-N jumpers.
• Connect Cell Extender output Tx/Rx and Rx ports (Bias-T blocks with DIN
connectors located on the connectors plate inside of the main cabinet) with Tx/Rx
and Rx ports of Main Lines of the proper sector using two DIN-DIN jumpers.
AC Connection
• 20A Breakers must be installed in the main electrical box (or A-box).
• 3-conductor AC-wire gage 12-14 must be run through metal conduit to the
electrical junction box inside of the CCI Cell Extender cabinet. The entry point to
this junction box is from the bottom of the cabinet via a corrugated shield.
• Run a standard 6 gauge grounding wire from the site’s main grounding bar
(Bus-bar in the A-box) to the CCI Cell Extender cabinet and secure it to the
electrical junction box inside the cabinet.
• Run Alarm cable through 1” conduit to the alarm card in BTS. Site technician
will make actual connection.
• Install the batteries:
a. Place the batteries in the bottom of the cabinet
b. Use the short jumper to connect the positive terminal of one battery to the
negative terminal of the other battery.
c. Cover the battery terminals with the supplied terminal boots.
• Confirm proper electrical connection
a. Turn off all breakers on PSU modules located in the Cell Extender cabinet;
b. Turn on breakers in the main electrical box (A-box)
c. Confirm that the green Power LED on PSU’s turn on.
Setting the RF Output Power on the CE-1819-125MC-XXXxX Cell Extender
The RF output power is adjustable on the Cell Extender. Use Gain Control Block that
contains a set of the input signal attenuators. The user must adjust the RF input power to
the Cell Extender connecting the proper pad such that the combined RF output power
level of any number of the individual carriers does not exceed the levels shown below in
order for the RF output spectral emissions to be compliant with the FCC spurious
emissions limit of -13 dBm outside of the assigned frequency block. These levels must
not exceed
Channel
Center
Frequency
(MHz)
1930-1990
Maximum
RF 0utput
(Watt)*
125
Maximum
RF 0utput
for Canada
(Watt)
63
This equipment complies with Part 24 of the FCC rules. Any changes or modifications
not expressly approved by the manufacturer could void the user's authority to operate the
equipment.
In order to comply with FCC rules for RF exposure, it must be observed that the antenna
connected to this equipment be fixed on an outdoor structure and that it must have a
minimum separation distance of 10 meters between it and any person.
In accordance with Industry Canada RSS-131, the manufacturer's rated output power of
this equipment is for single carrier operation. For situations when multiple carrier signals
are present, the rating would have to be reduced by 3.5 dB, especially where the output
signal is re-radiated and can cause interference to adjacent band users. This power
reduction is to be by means of input power or gain reduction and not by an attenuator at
the output of the device.
PCS block filters must be installed to achieve compliance with part 24 spurious emission
limits. Filters are manufactured by Clearcomm Technologies, part number CCFA-174XX . Connect the output filter port marked “BTS “ with the port on By-Pass module
marked “To BTS Duplexer”. Connect the filter port marked “ANT” to the By-Pass
module port marked “ From ANT Duplexer”. Connect the filter port marked “AMP
OUT” with corresponding attenuator port on Gain Control module. Connect filter port
marked “AMP IN” to the Amplifier module port marked “ RF OUT”.
* Reverse Link
Forward Link
PCS Operating Range
1850-1910MHz
1930-1990 MHz
Nominal 20 dB Bandwidth
60 MHz
39.27 MHz
PCS band specific filters
AD, BE, FC
AD, BE, FC
Nominal Pass-Band Gain
12 dB max
Adjustable to 13.94 dB max
System Noise Figure:
1.5.0 dB Max.
System Group Delay:
180 nanosecond Max
Pass Band Ripple:
+/-0.5 dB Max.
Output Third Order IM3 @
1.98 MHz 0ffset:
-55 dBc/30 kHz
1 dB Compression Point:
+15 dBm Min.
+58.5 dBm Typ.
Input /Output VSWR:
1.5:1 Max.
1.5:1 Max.
Up-Link-Down-Link Isolation 80 dB
By-Pass Insertion Loss
0.5 dB for ground level unit, 0.3 dB for tower top
unit
Nominal Mean Output
Power:
125 W ; 63 W for Canada
Input and Output Impedance 50 Ohm
Power Supply Voltage:
220 VAC
Power Consumption:
1.0 KW Max per sector
Dimensions
12”L x 5.5” W x 3”D -tower unit
77”H x 24”W x 21”D - ground level unit
Enclosure
NEMA 3R Weather Proof Cabinet
Connectors
Input from BTS –type N, F; output to hard lines -7
/16 DIN, F; TTA—7/16 DIN, F
Weight
TTA –10 Lbs, GLU –100 Lbs for one sector
Mounting
TTA –antenna pipe, GLU - concrete pad, 2.5’x2.5’
area
Operating Temperature:
-25° to +50° C Ambient
* With External Tower Mounted Amplifier

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Modify Date                     : 2007:05:03 16:14:31-03:00
Create Date                     : 2007:05:03 16:14:18-04:00
Page Count                      : 4
Creation Date                   : 2007:05:03 20:14:18Z
Mod Date                        : 2007:05:03 20:14:18Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : RUBY DULMAGE
Metadata Date                   : 2007:05:03 20:14:18Z
Creator                         : RUBY DULMAGE
Title                           : Authority to Act as Agent to a TCB:
Page Mode                       : UseNone
Tagged PDF                      : Yes
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NT3CE-1819-125MC

Navigation menu