Compal Electronics SHC100 Single Stream 802.11a/b/g/n/ac + BT 4.1 M.2 Type Card User Manual

Compal Electronics Inc Single Stream 802.11a/b/g/n/ac + BT 4.1 M.2 Type Card Users Manual

Contents

User Manual-2

Download: Compal Electronics SHC100 Single Stream 802.11a/b/g/n/ac + BT 4.1 M.2 Type Card User Manual
Mirror Download [FCC.gov]Compal Electronics SHC100 Single Stream 802.11a/b/g/n/ac + BT 4.1 M.2 Type Card User Manual
Document ID3972502
Application ID68EVG7l8ElUm1DSBY+0xXA==
Document DescriptionUser Manual-2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize319.38kB (3992311 bits)
Date Submitted2018-08-22 00:00:00
Date Available2018-08-22 00:00:00
Creation Date2018-08-14 10:53:21
Producing SoftwareAdobe PDF Library 10.0
Document Lastmod2018-08-14 10:53:31
Document TitleUsers Manual
Document CreatorAcrobat PDFMaker 10.1 Word 版
Document Author: 陳冠丞( Chen. BoPM (TPE) )

SHC-100

Ne pas immerger ou rincer le SHC ou ses périphériques. Si vous renversez
accidentellement du liquide sur l'appareil, déconnectez l'appareil de la source
d'alimentation. Contactez votre service Biomed en ce qui concerne la sécurité
continue de l'unité avant de la remettre en service.

Ne pulvérisez pas de produit de nettoyage sur le châssis.

N'utilisez pas de désinfectants contenant du phénol. Ne pas autoclaver ou nettoyer
le SHC ou ses périphériques avec des solvants forts aromatiques, chlorés,
cétoniques, éthers ou Esther, des outils tranchants ou des abrasifs. Ne plongez
jamais les connecteurs électriques dans l'eau ou d'autres liquides.

Ne rayez pas la surface de l'écran avec des objets durs.

Ne vaporisez pas de liquide directement sur l'écran ou laissez l'excès de liquide
s'égoutter dans l'appareil.

Ne placez aucun objet, tel que de la nourriture et des boissons, sur l'écran à tout
moment pour éviter d'endommager l'écran.

Nettoyez l'écran LCD uniquement avec un chiffon doux imbibé de 70% d'alcool
isopropylique ou de 70% d'alcool éthylique.
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 8
SHC-100
1.6 INTENDED USER PROFILE
Age: 25 - 60
Weight: Not relevant
Health: Not relevant
Nationality: Not relevant
Patient state: The patient will be the operator
Part of the body or type of tissue applied to or interacted with: Hands and fingers, expected
contact time shall be less than 1 min.
Education level: At least 8 years of intensive reading experience (school)
Knowledge:
Minimum – Can read and understand “westernized Arabic” numerals when written in Arial font
– Can distinguish every part of the body as described in the user manual
– Understands the potential risks and hazards regarding misjudgment of diagnostic images.
Language understanding: English or Chinese
Experience: Mentally and physically competent, specific medical training to read medical images
and to have a basic understanding of symbols.
Permissible impairments:
– Mild reading vision impairment or vision corrected to log MAR 0,2 (6/10 or 20/32)
– One arm/hand capable of guiding and holding the device
– An average degree of aging-related short-term memory impairment
– Hearing impairment of 40 % resulting in 60 % of normal hearing levels at 500 Hz to 2 kHz
Operating Principle:
A computer processing system panel with the following main components: the arithmetic logic unit
(ALU), the control unit, the memory, and the input and output devices (collectively termed I/O).
These parts are interconnected by buses, the control unit, ALU, and registers are collectively known
as a central processing unit (CPU), the unit processes and delivers patients electronic information to
an internal touchscreen.
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 9
SHC-100
Environment:
– General Requirements:
•
Hospital or clinics, professional healthcare personnel use only.
•
Indoor use only
•
Not for use in the shower, bathtub, or sink
•
The display is to be placed on a desk.
– Expected to function normally
– Conditions of visibility:
•
Ambient luminance range: 100 lux to 1,500 lux
•
Viewing distance: 20 cm to 40 cm
•
Viewing angle: Normal to the display ± 45°
– Physical:
•
Temperature range: 0°C to 40 °C
•
Relative humidity range: 10 % to 90 %, non-condensing
•
Relative altitude range: 0 to 3000m
The frequency of use: 1 to 10 times a day.
Mobility:
– Fixed MEDICAL DEVICE to be used beside a resting PATIENT.
– Fixed MEDICAL DEVICE to be used on a nursing cart.
Quality related risks are considered in FMEA (doc no. EFH00-PM-004), quality-related risks
are not considered as a result of harm; therefore risk evaluation only lists those which may cause
harm to the user.
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 10
SHC-100
Chapter 2 Hardware Description
2.1 SPECIFICATIONS
Bus Expansion
Intel® Core™ i5 7200U, 2.5GHz Processor, KBL
Intel® Core™ i5 7300U, 2.6GHz Processor, KBL
4G DDR4 SODIMM 2133/2666MHz (up to 32G)
500G HDD (Optional: SSD)
8 Megapixel
Intel® HD Graphics
Support Intel® Trusted Platform Module (TPM2.0) &
Wake-on-LAN/WiFi
M.2
Size
Max Resolution
Brightness
Contrast
Cleaned by Disinfectant
21.5” (54.6cm), 16:9
Full HD 1920x1080
LED backlight, 250 nits
1000:1
Isopropyl alcohol 70%, Ethyl alcohol 70%
CPU
Hardware
Memory
Storage
Camera
Graphic Chip
Chip Set
Display
Type
Light Transmission
Touchscreen
Durability
Surgical Glove Friendly
NFC/RFID
HDMI out
Earphone/Microphone
COM Port
Smart Card Reader
Card Reader(3 合 1)
Capacitive Touch (Multi-touch:10)
95%
30 million touches
Need
Rear: USB3.0*1+USB2.0*3, Side:USB2.0*1
1(included in USB ports, support Skype
Business )
1 (support 14443A、14443B、SRIX4K)
1 (Combo audio jack)
1 (RS-232)
Audio
Speaker
Microphone
3Wx2
1 (Integrated)
Network
LAN
WLAN
WiFi antenna
Bluetooth
10/100/1000/Gigabits Mbps RJ-45
802.11 a/b/g/n/ac
integrated or external
BT 4.1
Bus
Expansion
Mini-PCIe
Platform
Operating System
Win10
USB Port
Microphone in
I/O
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
for
Page: 11
SHC-100
Mechanical
Options
Power
Supply
Mounting
Dimensions ( W x H x D)
Weight
VESA 100*100 & 75*75 mm
535.2 x 375.7 x 50.4 mm
6.3 kg (with stand: 8.5 kg)
SSD
accessory port
Hand Set Holder
Input Voltage
Output
256G
ODD/ COM2+ USB2.0*3
Optional (support Skype for Business )
100 - 250 Vac, 1.5 - 0.75 A, @ 50 - 60 Hz
19 VDC, 3.15A
Cooling System
Operating Temperature
Storage/transportation
Temperature
Operating Humidity
Storage/transportation
Humidity
Environment Operating Altitude
Storage/transportation
Altitude
LED indicator
Vibration
Shock
Certifications
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Fanless
0 - 40° C
-20 - 60° C
10% - 90% (No Condensation)
10% - 90% (No Condensation)
700 - 1060 hPa
500 - 1060 hPa
White = turn on
1G
10 G
BSMI, CE,FCC Class B approval, IEC/ANSI60601-1
approved, UL 60950, UL 62368, RoHS, CCC, CEL
Date: 2018/07/16
Version: 0.7
Page: 12
SHC-100
2.2 EXTERNAL VIEW
2.2.1
Front View
Figure 2.2.1-1 Front View
2.2.2
Side View
Figure 2.2.2-1 Side View
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 13
SHC-100
2.2.3
Rear View
Figure 2.2.3-1 Rear View
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 14
SHC-100
Chapter 3 Installation
3.1 INSTALLATION PROCEDURES
3.1.1
Connecting the Power Cord
The SHC-100 should only be powered by a DC power adapter (DELTA MDS-060AAS19 B).
Be sure to always handle the power cords by holding the plug ends only.
Follow these procedures sequentially:
1.
Connect the female end of the power adapter to the DC-in power port of the PC. (See Figure
3.1.1-1)
2.
Connect the female end of the power cord to the DC power adapter.
3.
Connect the 3-pin male plug of the power cord to an electrical outlet.
Step 1
Step 2
Step 3
Figure 3.1.1-1Connecting the power
Warning! The SHC-100 is supplied by a 60 Watt power supply and a special adapter as depicted
Avertissement! for the mode abovel.
If a medical adaptor is connected to the SHC-100, the customer must ensure legal and
regulatory compliance and that the device meets the law and standards compliance
requirements of this hardware.
Le SHC-100 est alimenté par une alimentation de 60 watts et un adaptateur spécial tel
que représenté pour le modèle ci-dessus.
Si un adaptateur médical est connecté au SHC-100, le client doit s'assurer de la
conformité légale et réglementaire et que l'appareil répond aux exigences légales et aux
exigences de conformité de ce matériel.
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 15
SHC-100
3.1.2
Switching on the power
Push down the power button on the front panel of the SHC-100. (The color of the indicator
will turn white)
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 16
SHC-100
3.2 RUNNING THE BIOS SETUP PROGRAM
Your SHC-100 is likely to have been properly set up and configured by your dealer prior to
delivery. You may still find it necessary to use the BIOS (Basic Input-Output System) setup program
to change system configuration information, such as the current date and time or your type of hard
drive. The setup program is stored in read-only memory. It can be accessed either when you turn on
or reset the panel PC, by pressing the " F1 " key on your keyboard immediately after powering on
the computer.
The settings you specify with the setup program are recorded in a special area of memory called
CMOS RAM. This memory is backed up by a battery so that it will not be erased when you turn off
or reset the system. Whenever you turn on the power, the system reads the settings stored in CMOS
RAM and compares them to the equipment check conducted during the power on self-test (POST). If
an error occurs, an error message will be displayed on the screen, and you will be prompted to run
the setup program.
3.3 INSTALLING SYSTEM SOFTWARE
Recent releases of operating systems from major vendors include a setup program which loads
automatically and guides you through hard disk preparation and operating system installation. The
guidelines below will help you determine the steps necessary to install your operating system on the
PC’s hard drive.
Some distributors and system integrators may have already preinstalled system software
Note!
Remarque! prior to shipment of your PC.
If required, insert your operating system's installation or setup diskette into the external diskette
drive until the release button pops out.
The BIOS supports system boot-up directly from the CD-ROM drive. You may also insert your
system installation CD-ROM disk into your external CD-ROM drive. Power on or reset the system
and then enter the BIOS menu by pressing the “F1” key. And adjust the boot device sequence.
Or you can press “F12” key when booting, a bootable device popup menu will appear, you can
then select the bootable device that you want. The SHC terminal will automatically load the
operating system from the USB disk or CD-ROM. If you are presented with the opening screen of a
setup or installation program, follow the instructions on the screen. The setup program will guide
you through the preparation of your hard drive, and installation of the operating system.
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 17
SHC-100
3.4 INSTALL VESA MOUNTING
The SHC-100 also allows standard VESA mounting to help system integrators conveniently
integrate the PC into their system.
Only use mounting brackets provided by Compal to prevent unreliable mounting of the SHC100. VESA mount installation should be carried out by a professional technician; please contact a
service technician or your retailer if you need mounting service.
Installation instructions:
1.
First attach the wall-mount to the heat-sink of the SHC-100, securing it in place with the four
Phillips-head screws provided (M4 x L10).
2.
Mount on the wall, stand or another flat surface.
Warning! Be sure to secure the screws of the mounting bracket tightly. A loose joint between the
Avertissement! SHC-100 and mounting bracket may create a risk of injury.
Assurez-vous de bien serrer les vis du support de montage. Un joint lâche entre le SHC100 et le support de montage peut créer un risque de blessure.
Figure 3.4-1 VESA mount
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 18
SHC-100
3.5 TROUBLESHOOTING
See the technical support instructions below when the system behaves abnormally, such as in the
following conditions:
•
Failure to power on
•
Failure to power off
•
Power LED ON but no DC power output
•
AC power in and all switches ON, but the system doesn't power on
Contact your distributor, sales representative, or Compal's customer service center for technical
support if you need additional assistance. Please have the following information ready before you
call:

Product name and serial number

Description of your peripheral attachments

Description of your software (operating system, version, application software, etc.)

A complete description of the problem

The exact wording of any error messages

Symptoms, photo or video if available.
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 19
SHC-100
Chapter 4 Software
4.1 DISPLAY CONTROL SETTINGS
Step 1: Right-click on the desktop and select “Intel® Graphics Settings”
Step 2: Select “Display”
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 20
SHC-100
Step 3: Select “General Settings”
Set the Resolution and Refresh Rate.
Step 4: Select “Color Settings”
Set the Brightness, Contrast, Hue and Saturation.
Step 5: After all the settings have been completed, click “Apply”.
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 21
SHC-100
4.2 WINDOWS DRIVERS LIST
Please install the proper driver based on the SHC-100’s OS version (Win 10).
The following drivers are located on the driver CD in the path\Driver\ Folder.
Please install the drivers based on the sequence below:
Install sequence Folder Name
Chipset_Intel
Graphics_Intel
Audio
LAN_Realtek
Card reader
WLANBT_QCA
MEI
NFC
PL2303_Prolific_DriverInstaller_v1190
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Note
Version: 0.7
Page: 22
SHC-100
Chapter 5 Appendix
5.1 ANNEX
5.1.1 Guidance and manufacturer’s declaration – electromagnetic emissions
The model SHC-100 is intended for use in the electromagnetic environment specified below. The
customer or the user of the model SHC-100 should assure that it is used in such an environment.
Emissions test
Compliance
Electromagnetic environment –guidance
The model SHC-100 uses RF energy only for its
RF emissions
internal function. Therefore, its RF emissions are
Group 1
CISPR 11
very low and are not likely to cause any interference
in nearby electronic equipment.
RF emissions
The model SHC-100 is suitable for use in all
Class B
CISPR 11
establishments, including domestic establishments
and those directly connected to the public lowHarmonic emissions
Class A
voltage power supply network that supplies buildings
IEC 61000-3-2
used for domestic purposes.
Voltage fluctuations/
flicker emissions
Pass
IEC 61000-3-3
Table 5.1
5.1.2
Recommended separation distances between portable and mobile RF communications
equipment and the model SHC-100
The model SHC-100 is intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled. The customer or the user of the model SHC-100 can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the
model SHC-100 as recommended below, according to the maximum output power of the communications equipment.
Rated maximum output
Separation distance according to the frequency of transmitter m
power of transmitter W
150 kHz to 80 MHz
80 MHz to 800 MHz
800 MHz to 2,5 GHz
d = 1.2
d = 1.2
d = 2.3
0.01
0.1
10
100
0.12
0.38
1.2
3.8
12
0.12
0.38
1.2
3.8
12
0.23
0.73
2.3
7.3
23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters
(m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output
power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects, and people.
Table 5.2
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 23
SHC-100
5.1.3
Guidance and manufacturer’s declaration – electromagnetic immunity
The model SHC-100 is intended for use in the electromagnetic environment specified below. The
customer or the user of the model SHC-100 should assure that it is used in such an environment.
Electromagnetic
Immunity test
IEC 60601 test level
Compliance level
environment guidance
Floors should be wood,
concrete or ceramic tile.
±8 kV contact
±8 kV contact
Electrostatic
If floors are covered
±2 kV, ±4 kV, ±8 kV,
±2 kV, ±4 kV, ±8 kV,
discharge(ESD)
with synthetic material,
IEC 61000-4-2
±15 kV air
±15 kV air
the relative humidity
should be at least 30 %.
Mains power quality
±2 kV
±2 kV
Electrical fast
should be that of a
transient/burst IEC 100 kHz repetition
100 kHz repetition
typical commercial or
61000-4-4
frequency
frequency
hospital environment.
line to line
line to line
Mains power quality
±0.5
kV,
±1
kV
±0.5
kV,
±1
kV
Surge
should be that of a
line to earth
line to earth
IEC 61000-4-5
typical commercial or
±0.5 kV, ±1 kV, ±2 kV ±0.5 kV, ±1 kV, ±2 kV hospital environment.
Mains power quality
0% UT; 0.5 cycle
0% UT; 0.5 cycle
should be that of a
At 0°, 45°, 90°,
At 0°, 45°, 90°,
typical commercial or
135°, 180°, 225°,
135°, 180°, 225°,
hospital environment. If
270° and 315°
270° and 315°
the user of the model
Voltage dips
SHC-100 requires
IEC 61000-4-11
0% UT; 1 cycle
0% UT; 1 cycle
continued operation
and
and
during power mains
70% UT; 25/30 cycles
70% UT; 25/30 cycles
interruptions, it is
Single phase: at 0°
Single phase: at 0°
recommended that the
model SHC-100 be
Voltage
powered from an
interruptions
0% UT; 250/300 cycles 0% UT; 250/300 cycles uninterrupted power
IEC 61000-4-11
supply or a battery.
Power frequency
magnetic fields should
Power frequency
be at levels
(50/60 Hz)
30 A/m
30 A/m
characteristic of a
magnetic field
50 Hz or 60 Hz
50 Hz or 60 Hz
typical location in a
IEC 61000-4-8
typical commercial or
hospital environment.
NOTE UT is the a.c. mains voltage prior to application of the test level
Table 5.3
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 24
SHC-100
5.1.4
Guidance and manufacturer’s declaration – electromagnetic immunity
The model SHC-100 is intended for use in the electromagnetic environment specified below. The
customer or the user of the model SHC-100 should assure that it is used in such an environment.
Compliance
Electromagnetic
Immunity test IEC 60601 test level
resoult
environment – guidance
Portable and mobile RF
communications equipment should be
3 Vrms
used no closer to any part of the model
SHC-100, including cables, than the
recommended separation distance
calculated from the equation applicable
50 kHz to 80 MHz
to the frequency of the transmitter.
6Vrms in ISM bands
Conducted RF
Pass
IEC 61000-4-6 between 150 kHz
Recommended separation distance
and 80 MHz
d = 1.2
d = 1.2 80 MHz to 800 MHz
d = 2.3 800 MHz to 2,5 GHz
180% AM at 1 kHz
Radiated
RF EM
IEC 61000-4-3
3 V/m
80 MHz to 2.7 GHz
80% AM at 1 kHz
Where P is the maximum output power
rating of the transmitter in watts (W)
according to the transmitter
manufacturer and d is the recommended
separation distance in meters (m).
Pass
Field strengths from fixed RF
transmitters, as determined by an
α
electromagnetic site survey , should are
less than the compliance level in each
frequency rangeβ.
Interference may occur in the vicinity
of equipment marked with the
following symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects, and people.
α: Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM, and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To
assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If
the measured field strength in the location in which the model SHC-100 is used exceeds the applicable RF compliance level
above, the model SHC-100 should be observed to verify normal operation. If abnormal performance is observed, additional
measures may be necessary, such as reorienting or relocating the model SHC-100.
β: Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 25
SHC-100
5.1.5
Names and contents of harmful substances in products (TW)
限用物質及其化學符號
單元Unit
鉛
(Pb)
汞
(Hg)
鎘
(Cd)
六價鉻
(Cr+6 )
多溴聯苯
(PBB)
多溴二苯醚
(PBDE)
印刷電路板組件
(含處理器)
-
○
○
○
○
○
硬碟
-
○
○
○
○
○
光碟機(選配)
-
○
○
○
○
○
記憶體
-
○
○
○
○
○
電腦I/O配件
-
○
○
○
○
○
電源供應器
-
○
○
○
○
○
機殼
-
○
○
○
○
○
螢幕
-
○
○
○
○
○
-
○
○
○
○
○
散熱模組
-
○
○
○
○
○
喇叭(選配)
-
○
○
○
○
○
相機(選配)
-
○
○
○
○
○
麥克風(選配)
-
○
○
○
○
○
無線裝置(選配)
-
○
○
○
○
○
腳架(選配)
-
○
○
○
○
○
配件
(含電源線)
備考1.〝超出0.1 wt %〞及〝超出0.01 wt %〞係指限用物質之百分比含量超出百分比含量基準值。
備考2.〝○〞係指該項限用物質之百分比含量未超出百分比含量基準值。
備考3.〝-〞係指該項限用物質為排除項目。
Tabel 5.5 Taiwan RoHS
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 26
SHC-100
5.1.6
产品中有害物质的名称及含量 (China)
有害物质
部件名称
铅(Pb)
汞(Hg)
镉(Cd)
六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
印刷电路板组件
○
○
○
○
○
硬盘
○
○
○
○
○
光驱
○
○
○
○
○
内存
○
○
○
○
○
计算机I/O附件
○
○
○
○
○
电源
○
○
○
○
○
机箱/附件
○
○
○
○
○
电池
○
○
○
○
○
本表格依据SJ/T 11364的规定编制
○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572规定的限值要求以下。
X:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 26572规定的限值要求。
注:表中标记”X”的部件均符合欧盟 RoHS 立法。
Tabel 5.6 China RoHS
File: SHC-100 User manual(Eng)_V0.7 (LT
Edit).docx
Date: 2018/07/16
Version: 0.7
Page: 27

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2018:08:14 10:53:31+08:00
Create Date                     : 2018:08:14 10:53:21+08:00
Metadata Date                   : 2018:08:14 10:53:31+08:00
Creator Tool                    : Acrobat PDFMaker 10.1 Word 版
Format                          : application/pdf
Title                           : 標準文件範本
Creator                         : 陳冠丞( Chen. BoPM (TPE) )
Document ID                     : uuid:e8a6ef05-b901-4843-bf03-006213019fac
Instance ID                     : uuid:6647dbd6-b92b-4bce-bb51-d5ef451ff2c3
Producer                        : Adobe PDF Library 10.0
Page Count                      : 20
Author                          : 陳冠丞( Chen. BoPM (TPE) )
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GKR-SHC100

Navigation menu