Computime GES2181 Energy Saving Thermostat User Manual

Computime Limited Energy Saving Thermostat Users Manual

Users Manual

Download: Computime GES2181 Energy Saving Thermostat User Manual
Mirror Download [FCC.gov]Computime GES2181 Energy Saving Thermostat User Manual
Document ID1318359
Application IDzQ5eWMz0JY9Uc7ch13gMhQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize25.56kB (319550 bits)
Date Submitted2010-07-28 00:00:00
Date Available2010-07-28 00:00:00
Creation Date2010-07-16 11:19:21
Producing SoftwareAcrobat Distiller 8.0.0 (Windows)
Document Lastmod2010-07-16 11:19:33
Document TitleUsers Manual
Document CreatorAcrobat PDFMaker 8.0 for Word
Document Author: Henry

Energy Saving Thermostat
[Insert product picture]
Instruction Manual
Model no. GES2181
CONTENTS
PRODUCT OVERVIEW
The GES2181 Energy Saving Thermostat can connect to 3 Heat / 2 Cool conventional Heat Pump HVAC
systems. The thermostat’s smart ZigBee™ technology enables it to communicate with your utility
company so you can receive messages about energy saving events and price reductions. In addition, the
easy‐to‐use interface makes it simple to control your energy consumption.
SAFETY INSTRUCTIONS
Purpose and correct use:
•
Read these instructions carefully and keep in a safe place for future reference.
•
Only an authorized, qualified installer should install this unit. All manual / safety instructions
and electricity supplier’s regulations must be adhered to.
•
Only connect this unit to a 24‐volt A/C power source.
•
Do not install this unit at an altitude of over 2000 meters.
•
This standalone mounted electronic unit serves as a temperature control system only in dry,
closed living and office spaces. Do not place the unit in a bathroom or area of excessive
moisture. Do not allow the unit to get wet.
•
Place the unit in an easy‐to‐reach position where you can comfortably reach the buttons and
view the screen.
•
Do not expose the unit to: temperatures below 5°C or above 40°C; humidity above 80% or
pollution above level 2.
•
Do not expose the unit to voltage fluctuations of more than +/‐ 10%.
•
Clean the unit with a dry, soft cloth. Do not use solvents or aggressive cleaning agents.
The manufacturer accepts no responsibility for damage caused by non‐observance of these
instructions.
Environmental Protection
Unwanted electrical appliances can be recycled and should not be discarded along with regular
household waste. Please help to support the conservation of resources and protect the environment by
returning this appliance to your nearest collection centre (if available).
INSTALLATION
Please refer to Appendix for installation guide.
HOME SCREEN
The Home screen is the main display screen. If you do not press
any buttons for 30 seconds, the thermostat will return to the
Home screen.
Comment [Kairy1]: Added below
The large temperature reading on the Home screen is the current temperature. The small temperature
reading is your setpoint temperature.
To quickly change the setpoint temperature:
Press UP or DOWN.
When you receive an event or message from the utility company, ‘Event’ or ‘Message’ appears on the
bottom of the Home screen and advises how many events or messages you have received, and the
event’s level of importance.
SET HEAT/COOL MODE
1.
When you are in the Home screen, press SYS and the
screen opposite appears.
2.
Press SYS repeatedly to select one of the following
options:
3.
•
‘Heat’, ‘Cool’ or ‘Off’ (Conventional HAVC)
•
‘Heat’, ‘Emer’ (Emergency Heating), ‘Cool’ or ‘Off’
(Heat pump HVAC)
Press MENU to confirm your selection and return to the Home screen.
Note: Make sure you press MENU to confirm your changes or they will not be saved.
SET FAN MODE
1.
When you are in the Home screen, press FAN and the
screen opposite appears.
2.
Press FAN repeatedly to select ‘Fan On’ or ‘Fan Auto’.
3.
Press MENU to confirm your selection and return to
the Home screen.
Notes:
•
When the fan is set to ‘Auto’ it only runs when the heating/cooling system is working.
•
Make sure you press MENU to confirm your changes or they will not be saved.
MAIN MENU SETTINGS
1.
When you are in the Home screen, press MENU and
the screen opposite appears.
2.
Press UP or DOWN to scroll through the Main menu options.
3.
Press SELECT to enter a menu.
Note: Make sure you press MENU to confirm your changes or they will not be saved.
Override menu
When you receive an event or message from the utility company, ‘Event’ or ‘Message’ appears on
the bottom of the Home screen and advises how many events or messages you have received, and
the event's level of importance. You can view the details by repeatedly pressing INFO (see the
‘Viewing events and messages’ section for more information).
In the Override menu, you can choose to accept or reject events and messages, and set the
thermostat to ‘Vacation’ to override the programmed settings.
To reject events:
1. Select and enter the Override menu.
2.
Press UP or DOWN to select ‘Reject Current Event’ or ‘Reject
All Events’.
3.
Press SELECT to confirm. If you reject an event, a message
appears to ask if you are sure you want to reject it, press
SELECT to confirm the rejection or MENU to return to the
previous screen.
Note: Once you have rejected a current event, the unit will continue to reject all new events. If you
have rejected all events, the unit will reject all events stored on the system and any new events that
may occur. To enable the unit to accept events once again, you must select ‘Accept Current Event’
or ‘Accept All Events’ as shown below.
To accept events:
1. Select and enter the Override menu.
2.
Press UP or DOWN to select ‘Accept Current Event’ or ‘Accept
All Events’.
3.
Press SELECT to confirm.
Note: The unit will automatically accept events unless you have
set it to reject events and vice‐versa.
To set your vacation time:
This setting will override your selected program settings in the Program menu while you are on
vacation.
1. Select and enter the Override menu.
2.
Press UP or DOWN to select ‘Vacation’ and the screen
opposite appears.
3.
Press SELECT to confirm.
4.
Use UP or DOWN to scroll through the settings and
press SYS or FAN to change a setting. You must set the
‘Vacation Mode’ to ‘On’ to activate this function.
5.
Press MENU to confirm and return to the previous screen.
When the vacation mode is activated, your utility company can override your temperature setting
when the new event setting saves energy, for example:
a)
In wintertime when the outdoor temperature is cold, you may set your vacation
temperature to 10°C to prevent pipes from freezing. However, if the utility company sends
an event to reduce the temperature to 8°C to save energy, it will override your vacation
temperature and make the new ‘Heat Set Point’ 8°C.
b) In summertime, if you have set your vacation temperature to 20°C and the utility sends an
event to increase the temperature to 25°C in order to save energy, it will override your
vacation temperature and make the new ‘Cool Set Point’ 25°C.
Note: The utility company cannot override your vacation temperature if you have set the unit to
‘Reject All Events’.
Program menu
To edit the time and temperature settings for any day of
the week:
1.
Select and enter the Program menu and the screen
opposite appears.
2.
Use UP or DOWN to scroll through the settings and
press SYS or FAN to change a setting.
3.
Press MENU to confirm and return to the previous
screen.
To copy or reset a program:
1. Select and enter the Program menu.
2.
Press INFO and the screen opposite appears.
3.
Use UP or DOWN to select ‘Copy Program’ or ‘Reset
program’ and press SELECT to confirm.
•
If you selected ‘Copy Program’, use the UP and
DOWN buttons to select a day that you want
the program settings to be copied to and press SYS until the ‘N’ changes to a ‘Y’. Then
press SELECT and ‘Successfully Copied’ displays.
•
If you selected ‘Reset program’, ‘Are you sure you want to RESET the program?’ appears.
Press SELECT to confirm or MENU to exit and return to the previous screen. When you
reset the program, all the Program menu settings return to the factory default settings.
Setup menu
To edit the Setup menu:
1. Select and enter the Setup menu and the screen
opposite appears.
2.
Use UP or DOWN to scroll through the settings and
press SYS or FAN to change a setting.
3.
Press MENU to confirm. Here’s a list of what the
Setup menu settings mean:
Unit
Span
Fan
Filter
Default
Time
Date
Get Network
Time
Changes the display measurement from Celsius to Fahrenheit or vice‐versa. If you select this
option, ‘This action will restore all user [thermometric] settings to the default settings.
Continue?’ displays. Press SELECT to confirm or MENU to exit and return to the previous
screen.
Changes the temperature span from 0.5 to 2.0°F in increments of 0.5°.
The fan will continue to run for 0, 30, 60 or 90 seconds after cooling is turned off.
Sets a time (up to 500 hours) for the system to remind you to change or clear the fan’s filter.
If you select this option, ‘Are you sure to RESTORE all settings to factory default’ displays. Press
SELECT to confirm or MENU to exit and return to the previous screen.
Changes the time.
Changes the date.
If you select and confirm ‘Yes’, a signal will be sent out to search for the network time and this
will be updated on your thermostat.
Networking menu
The networking menu advises if the thermostat is communicating with your utility network or if you
are disconnected from the network.
To connect to your utility network:
1. Select and enter the Networking menu.
2.
If you not connected to your utility network, the ‘Not
Connected’ screen appears.
3.
Use UP or DOWN to select one of the following:
•
‘Auto’ – enables an automatic scan for the
channel.
•
‘All’ – searches all channels.
•
‘Channel’ – If you know your channel number enter it here (numbers 1 to 26).
Note: If your assigned channel number has more than one ID number you can use UP or DOWN
to scroll through and select your preferred ID.
4.
Press SELECT to confirm and start the channel search.
5.
When you have successfully connected, the ‘Joined’ screen appears and the LED light is green.
It will take approximately one minute for the connection process to complete. If you experience
problems connecting to your utility network, please contact your utility company.
To disconnect from your utility network:
1. Select and enter the Networking menu. You should see the
‘Joined’ screen opposite.
2. Press SELECT to disconnect and the message ‘Are you sure?’
appears.
3. Press and hold MENU and INFO simultaneously to confirm, or
press MENU to exit and return to the previous screen.
Note: The right LED lights up when you are disconnected.
Query menu
The query menu allows you to retrieve and view recent events, prices or messages from your utility
company.
1. Select and enter the Query menu and the screen
opposite appears.
2.
Use UP or DOWN to scroll through the onscreen
queries and press SELECT to enter the menu option:
•
‘Get event’ – Press UP or DOWN to select the
time and date. Use SYS or FAN to enter the date
you wish to view events from. Then use DOWN to
scroll to the last setting in the menu and this will automatically send out your query.
•
‘Get current price’ – When you select this option your request to be notified of the current
price options will automatically be sent out.
•
‘Get schedule price’ – Follow the same steps as ‘Get event’ to automatically send out your
request for the schedule price.
•
‘Get last message’ – When you select this option your request to be notified of your last
message received will automatically be sent out.
Note:
•
If ‘Please join network first!’ appears on the display, you need to connect your thermostat
to the utility network (see the Networking menu section for details).
•
A reply to your query should be received within 15 seconds.
VIEWING EVENTS AND MESSAGES
1.
When you are in the Home screen, press INFO repeatedly to view the following notifications
from your utility company:
Screen
Description
An Event
EVENT:
• Pending – An event will happen at the START TIME.
• Active – This event is currently in progress.
• Rejected – You have rejected this event.
LEVEL: There are 9 different event levels:
•
•
•
•
•
Green – Energy saving
Levels 1‐5 – Level of message importance; 1 is low and 5 is high
Emergency
Planned outage
Service Disconnect
START TIME: The event will start at this time i.e. 8am.
DURATION: The event will last for this duration i.e. 2 hours.
A Price
Your current energy usage is priced at Level 1, which is currently
$2.2 per kilowatt‐hour.
A Message
Your utility company will send you a wide range of messages.
When prompted on the screen, press XXXX to confirm that you’ve
read a specific message.
If the message needs the end user to make a confirmation,
or a Cancel command for a previous message needs to be
confirmed, the “Confirm” button guides the user to confirm
it.
Network Information
SUPPORT – Call this telephone number for support.
CHANNEL – Write down your channel number and put it in a safe
place. It may be useful if you need to reconnect to the network.
SHORT / PAN / EPAN / EU164 / FIRM / HVAC – If you phone for
support you may be asked to provide these codes.
2.
When viewing any of these screens, look in the top right‐hand corner to see how many pages
there are i.e. 1/2. Use the UP and DOWN buttons to scroll through to the end of the message.
INDICATORS
There are two LEDs. One is Yellow in color and the other is tri‐color. The Yellow LED is for For HVAC
system indication and Tri‐color (Green, Orange and Red) for Utility Information indication.
Yellow Color LED:
HVAC system working normal: Off
HVAC system working normal with Network Identify Request from Server or utility company:
Flashing
HVAC system error/warning: On
Tri‐color (red, green and) LED:
Demand Response from Utility Company is running: Red LED on
Current energy price is at Low level: Green LED on
Current energy price is at Medium: Green LED on
Current energy price is at High level: Orange LED on
Current energy price is at Critical level: Red LED on
PRICE TEMPERATURE OFFSET
There are (3) three settings programmed in the thermostat in response to different
energy price level.
Below is a table of for the Price temperature offset:
Energy Level
Medium
High
Critical
LED Indicator
Green
Orange
Red
Offset (in F)
For example, if the current programmed temperature is 75F and the current price level
from utility company is High (Orange, the actual set point for the home will be 79F.
RESET
To reset the unit, insert a thin, blunt instrument into the RESET hole on the side of the unit. Please note
that resetting the unit will return it to the factory default settings.
SPECIFICATIONS
Temperature unit
°C/°F
Operating temperature
32 – 113 °F (0 – 45 oC)
Indoor temperature measurement range
40 – 99 °F (5 – 37 oC)
10
RF frequency
2.40 – 2.48 GHz
RF range
Up to 1300 Ft (400m) Line of Sight
A/C power
18‐30 V AC at R and C terminals
13.6 (L) x 10.6 (W) x 2.6 (H) cm
Size
5.4” (L) x 4.2” (W) x 1” (H)
Weight
0.76lb (345g)
FCC DECLARATION
Warning: Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user’s authority to operate the
equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
FCC RF Radiation Exposure statement:
This equipment complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20 centimeters between the radiator and your body.
ETL
This thermostat is a Class 3 product and must be operating by approved power
source under 18-30VAC. It must be connected to 18-30VAC supply of HVAC
System or transformer approved by UL/cUL/CSA.
Disconnection means: Type 1B
Pollution Degree: 2
11
Rated Impulse voltage: 330V
For installation, please refer to the installation and wiring diagram under
Appendix.
Warning: Do not connect any of the terminals to 110V/220V AC supply.
12
Appendix: Installation and Wiring Diagram
Terminal definition
Heat Pump
Terminal
Conventional Heat Cool System
System
No use
24VAC common for control circuit and thermostat
power input
Fan
1st stage cooling
1st stage compressor
2nd stage cooling
2nd stage
compressor
1st stage heating
Auxiliary heating
W2/E
2nd stage heating
Emergency heating
W3/O/B
3rd stage heating
Changeover valve
RH
24VAC Power supply for Heating side
RC
24VAC Power supply for Cooling side
Y2
System monitor
13
Wiring diagram for Heat pump system
Aux heating
Emergency
14
Wiring diagram for conventional Heat Cool system
© 2010 Computime Limited
15

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 8.0.0 (Windows)
Source Modified                 : D:20100716031908
Create Date                     : 2010:07:16 11:19:21+08:00
Creator Tool                    : Acrobat PDFMaker 8.0 for Word
Modify Date                     : 2010:07:16 11:19:33+08:00
Metadata Date                   : 2010:07:16 11:19:33+08:00
Document ID                     : uuid:d38e6699-42c8-46c1-ae98-96848b6bd3c9
Instance ID                     : uuid:d9f156a3-b59a-4300-835d-7ad8e843ecf5
Subject                         : 13
Format                          : application/pdf
Creator                         : Henry
Title                           : 
Page Count                      : 15
Page Layout                     : OneColumn
Author                          : Henry
EXIF Metadata provided by EXIF.tools
FCC ID Filing: DI2GES2181

Navigation menu