Connect Outdoors CS2015 ConnectScale Digital Fish Scale User Manual CS 55 1 Manual

ConnectScale, LLC ConnectScale Digital Fish Scale CS 55 1 Manual

Manual

Manual to ConnectScale Digital Fish Scale
Model No.CS-55-1
Note: The data might be a little different from the sample, please kindly inform us for
updating and modifying if the test result different from this manual.
Basic:
1. Capacity/ Division: 1) 25KG(26KG MAX)/10g 2) 50KG(51KG MAX)/10g
2. Division: KG0.01kg LB0.01 LB OZ0.1 OZ
3. Weighing Unit KG/ LB/ OZ/ / with key to make switch
4. Tolerance 1/5000
5. Hold Auto hold, with “HOLD on screen
6. Screen OCS-26-LCD5unit, size mm
7. Over load indicationwhen weight over 1kg than capacity, will indicate ”O-Ld
8. Low power indicate the screen shows “Lo” when power lower than 1V(±0.2V)
9. Auto turn off 60S
10. back light yes 15s no operating after turn on, the back light auto shut off
11. Buzzer yes.
12. Function of keys [ON/OFF]---turn on/ turn off[UNIT]---unit switch
[RESET]--- clear.
13. Temperature test 0~60/1℃, 10~40℃±2(after calibration) 32~122/1
(=1.8*+32
14. ON/OFF statusturn on showsHELLOturn off showsbYE
15. Factory calibration 1 o’clock 25kg
16. Data transfer Bluetooth 4.0 UARTwave 960081communication
commissionsingle sending data
17. Data sending sclae forward basic kg and basic data
18. Data receiving not available
19. Distance wireless bluetooth reach distance at idea condision20 m, with wall
5 m
20. Working condition 0~40℃, RH< 90%
21. Power DC3V 2 pcs no.7 aa battery currentworking currentnot
including back light) about 5.9mAtotal currentwith back light 8.8mAshut off
current 10~20uAwith 3V power supply)
Operation
1. Weighingput battery inthe scale sounds discreen shows HELLOthen
shows0.00kg . Hang weight on the hook, indicate weight change. The screen
shows weight changed, when stabled, screen showHOLDand soundsdi. Then
this weight will be sentAfter hold, press [ON/OFF]could unholdpress key
[RESET]could clear the weight and restart weighing. No weight statuspress key
[ON/OFF] when showsbYEturn offmeanwhile sending turn off code
2. Working statuspress key [UNIT] can switch unitunit could be KGÆ LBÆ
OZÆ Æ ℃;when choose temperaturewill send data(℃)
3. Press[ON/OFF]after set battery, auto choose hold mode. After turn on, press key
[RESET] for 3S until the screen showsH-oFF, means Hold function offpress
[RESET]for 3s secondly, the screen showsH-on, means Hold function is on
4. Turn off code transferred when turn offoverload showsO-Ldand send overload
codelow power showsLoand send power error code
Calibration
1. Temperaturepress [ON/OFF] turn on when it shows HELLO press
[ON/OFF] 4 times and keep last press about 1S when it showsCmeans
temperature calibrating statuspress [ON/OFF] within3s, when screen shows
calibrating times0x then shows35Cinto temperature calibrating. Then press
[UNIT] to adjust temperature same as working condition, then press [ON/OFF] to
confirm the temperature and finish temperature calibrating and into weighing
calibrating. Please check the following for weight calibration.
2. Weigh calibrationpress [ON/OFF] to turn onwhen it showsHELLOpress
[ON/OFF] 4times fast and keep the last time 1S until it showsC. Waiting 3s without
any operation, the scale will into weighing calibration auto. It indicates inner weight
code. Then press [ON/OFF]shows calibration time 0y then show2510means
25kg/10gPress [UNIT]could choose Capacityshows 5010means 50kg/10g
Then press [ON/OFF]to confirm into weighting calibration status. When it shows
25kg, put 25kg weight, it will shows PASS means calibration finished and back to
weighing status.
RemarkWhen temperature calibration time over 8 times and weight calibration over
10 times, it showsiEr
Wire
1. Power wire3V supply please pay attention to +/_, wrong power might destroy the
IC.
2. Sensor wire. Red wire V+ or E+, black wire V-or E-, rest 2 wire for S+ & S-.
3. With power supply, into inner weight status checking, pull sensor, if inner weight
increase, the wire in right status, if inner wight decrease, means sensor wire wrong
status, please check S+ and S- status.
FCC Statement:
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
IC Statement
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et (2)l'utilisateur de l'appareil doit accepter
tout brouillage radioélectrique subi,même si le brouillage est susceptible d'en compromettre
le fonctionnement.

Navigation menu