Controlled Entry Distributors DOL433RC2SQ Remote Controller User Manual

Controlled Entry Distributors, Inc. Remote Controller Users Manual

Users Manual

Download: Controlled Entry Distributors DOL433RC2SQ Remote Controller User Manual
Mirror Download [FCC.gov]Controlled Entry Distributors DOL433RC2SQ Remote Controller User Manual
Document ID2743960
Application IDzUlxx6IX+g0BV6ZdRuoNLA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize100.31kB (1253865 bits)
Date Submitted2015-09-11 00:00:00
Date Available2015-09-11 00:00:00
Creation Date2015-08-17 14:07:51
Producing SoftwaredoPDF Ver 7.3 Build 391 (Windows 7 Business Edition (SP 1) - Version: 6.1.7601 (x64))
Document Lastmod2015-08-17 14:17:02
Document TitleUsers Manual

CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
TECHNICAL CONSTRUCTION FILE
Marchio
(Brand)
PRODOTTO
Serie
(Product )
(Serie)
KEYPAD DOLPHIN
Modello
DOCUMENTO
( Document )
N° PAGINE
(Page Number)
DATA DI RILASCIO
(Date of issue)
TRANSMITTER SOLUTIONS
(Types)
KPD2641C2
TCF-157
FILE
D:\Prodotti\Tastiere dolphin\Dolphin 2ch\TCF-157.doc
ALLEGATI
19
(Attachments)
30/7/2015
REVISIONE
(Revision)
Realizzato
Verificato
Approvato
(Performed)
(Verified)
(Approved)
G.M.Dalle Carbonare
L. Braido
G.M.Dalle Carbonare
--------------------------------------------
--------------------------------------------
--------------------------------------------
TCF-157
07/2015
Pag 1 of 19
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
SUMMARY
1.0
Introduction ................................................................................................................... 3
2.0
Technical characteristics....................................... Errore. Il segnalibro non è definito.
3.0
System components ..................................................................................................... 4
4.0
Description.................................................................................................................... 7
5.0
Schematic block diagram .............................................................................................. 9
6.0
Reference regulations ................................................................................................. 10
7.0
Electrical diagrams...................................................................................................... 11
8.0
Component Layout...................................................................................................... 14
9.0
Component list ............................................................................................................ 16
10.0 PCB Boards ................................................................................................................ 17
11.0 PHOTOS .................................................................................................................... 18
TCF-157
07/2015
Pag 2 of 19
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
1.0
Introduction
The keypad DOLPHIN type KPD2641C2 is an encoded radio keypad operating at 433,92 Mhz in
ASK.
Best use of the product is to control: gates, garage doors, rolling shutters, sun-blinds, anti-burglar
appliances, lightings, etc. The code has a very high security encoding system (KeeLoq ® Hopping
code). The code sent by the transmitter changes at every activation, avoiding any scanning and
copying risk. A special algorithm allows keeping synchronized transmitter and receiver.
The radio transmission is enabled only after the dialing of a security user code.
There are 2 different channels, identified with the buttons «*» and «#», that can activate 2 different
receivers or relays.
The internal memory can store up to 22 different security user codes and 1 Master code.
The product fully complies with the FCC Rules cfr 47 part 15.
1.1
Product references
BRAND :
Transmitter Solutions
SERIES :
KEYPAD DOLPHIN
TYPES :
KPD2641C2
MANUFACTURER : CDVI WIRELESS S.p.A.
Via Piave, 23
I-31020 S.PIETRO DI FELETTO ( TV)
ITALY
Tel: +39-0438-450860
Fax: +39-0438-455628
CONTACT : Ing. G. Massimo Dalle Carbonare – Product Manager
TCF-157
07/2015
Pag 3 of 19
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
2.0
Technical specifications
Number of keys:.................................................................12
Number of channels: ..........................................................2 ( A, B)
Supply:...............................................................................3,6 Vdc
Battery duration:.................................................................about 24 months
Battery type:.......................................................................LI-SOCl2 – LS14505
Current consumption:



Sleep mode ............................................................0,1 μA
Pre-stand-by...........................................................0,88 μA
transmission ...........................................................28 mA
Operating frequency band .................................................433,05  434,790 MHz
Carrier frequency: ..............................................................433,920 MHz
Rated frequency tolerance: ................................................ 75 KHz
Modulation: ........................................................................AM/ASK
E.r.p. ( rated ):....................................................................5 - 10 μW
Modulating signal frequency:..............................................834 bit/sec
Channel width: ...................................................................> 25 KHz
Dynamic code system ........................................................Keeloq® Hopping code
Security Code combinations number:.................................264
User security code number: ...............................................22
Master security code ..........................................................1
Transmission duration:.......................................................2 sec.
Range in open space: ........................................................from 50 to 100 m
Operating temperature: ......................................................from -10 °C to +55 °C
Dimensions: .......................................................................115 x 90 x 55 mm
Weight: ..............................................................................210 g
IP Protection Grade: ..........................................................IP54
Buzzer
TCF-157
07/2015
Pag 4 of 19
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
3.0
Mechanical drawings
3.1
External view
3.2
Dimensions
TCF-157
07/2015
Pag 5 of 19
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
3.3
Internal exploded view
TCF-157
07/2015
Pag 6 of 19
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
4.0
Description
The 2ch DOLPHIN KEYPAD is a 2-channel radio keypad operating at 433,92 Mhz in AM/ASK
modulation.
It’s fully compatible with any receiver of the range ERONE
The RF signal is generated dialing a valid 4 or 5-digits code and then pushing the keys * or #
The internal memory can store 1 Master code and up to 22 User codes.
Each code is composed by 4 or 5 digits
The Master code allows managing the single user codes (memorize and delete)
The Default master code is 12345.
With the Master password [ 12345] doesn’t occur any RF transmission;
The keypad is only 2-channels [* or # ];
The system analyses any code sequence and keeps valid the last 4 or 5 digits typed before the *
or #.
If they bring a valid code the transmission is effected otherwise if the code dialed before pushing *
or # is wrong there is a long beep [beeeeeeep];
If the combination is valid after the key * or # activation, there is a “beep” and the led under key
N°5
starts blinking (slow) and all the rest of the led of the keypad switch off. The led 5 keeps on blinking
as long as the key * or # is pressed;
A timeout of 25 sec. limits the duration of the transmission;
Code combinations shorter than 5 digits are not accepted;
After the activation of any key there is a timeout of 3 sec. after which the combination is discarded
and must start again;
The 4 blue led of the keypad are normally off. After the pressure of any key, all the led switch on;
If no keys are activated the led switch off after 3 sec.;
By dialing 2 times the Master password ( 12345, 12345) you enter in a menu: all the led switch
OFF and the led 5 switch ON. From that menu are possible many functions.
*+X : means the button A followed by another button among : 0, 1, 4 ,5 and 6.
If, after the dialing of the 2 Master password, no buttons are pressed within 10 sec., the keypad
comes back to the normal mode.
If you want to exit from the menu before the 10 sec. it is enough to press the button #.
When the keypad is waiting for a code (as for the master password change or a new user code)
the led 5 keeps on blinking. If no code is dialed within 10 sec the keypad comes back to normal
mode.
Battery low
When the value of the battery voltage is drops under 3V, at the first access to the keypad, the all
led make 7 fast flashes before to get stable on
4.1 Buzzer ON/OFF
It is possible to put the buzzer ON or OFF ( in toggle way )


Master pwd, Master pwd, *,6, (beep) : set the buzzer ON if currently OFF
Master pwd, Master pwd, *,6, (beep) : set the buzzer OFF if currently ON
TCF-157
07/2015
Pag 7 of 19
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
4.2
Stand-by transmission
This is a function useful when the S/N of the keypad must be memorized into the corresponding
receiver.
Sometimes the receiver and the keypad are already fixed, may be far each other, and so it
becomes difficult to enter into the memorization procedure of the receiver and then dial the user
code and get the RF signal within the time-out the receiver
So has been created a new option, called “Stand-by transmission”.
The concept is that:
- 1) I enter in a special menu on the keypad, I preset the transmission but I don’t make the RF
transmission and I set the keypad into a stand-by status with 30 sec. of time-out,
- 2) I enter into the receiver memorization menu of the desired relay.
- 3) I come back to the keypad and I press * or #, the RF transmission is effected and the S/N is
memorized into the receiver.
In this way I’ve 30 seconds to memorize the keypad into the receiver.
This is just a choice, because I can use even the standard way to have a RF transmission, simply
dialing the user code XXXXX and the button * or #.
master pwd, master pwd, *, 2, (beep), xxxxx [The user code must be present in the memory]
At this point, the led 5 starts to blink slowly.
Then, press * or # and the RF transmission is effected.
If no buttons are pressed within 30 sec. the procedure finishes.
4.3 HIDDEN FUNCTIONS
These 2 functions allow recovering the factory settings, if the master password is lost.
It is possible to reset the master password to the factory value [12345] leaving unchanged the user
memory but even reset the keypad at the factory defaults, erasing completely the user memory.
Master password reset ( reset the master password to 12345 and doesn’t affect the memory )
* + 1 simultaneously for 30 sec. , beep-beep, XXXXX (valid) beep-beep-beep
If the valid code is dialled within 20 sec. the procedure ends successfully otherwise nothing
changes
Total reset to factory default ( cancel all users codes + reset master password to 12345
# + 3 simultaneously for 30 sec , beep-beep-beep-beep
4.4) Regular RF Transmission
XXXXX, * or #, (Beep)
Code valid : Led N°5 blinks
Code not valid : Biiiiiiip
The device is approved by the FCC and it complies with Part 15 of the FCC Rules.
Its operation is subject to the following 2 conditions:
1. This device may not cause harmful interference.
2. The device must accept any interference that may cause undesired operation.
TCF-157
07/2015
Pag 8 of 19

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2015:08:17 14:17:02+08:00
Create Date                     : 2015:08:17 14:07:51+08:00
Metadata Date                   : 2015:08:17 14:17:02+08:00
Format                          : application/pdf
Document ID                     : uuid:d5d7966f-ff16-4295-8afd-c6d0511c724f
Instance ID                     : uuid:69e67d46-1427-4b42-964e-f4ec26a446b0
Producer                        : doPDF Ver 7.3 Build 391 (Windows 7 Business Edition (SP 1) - Version: 6.1.7601 (x64))
Page Count                      : 8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SU7DOL433RC2SQ

Navigation menu