Controlled Entry Distributors INOX Remote Controller User Manual

Controlled Entry Distributors, Inc. Remote Controller Users Manual

Users Manual

Download: Controlled Entry Distributors INOX Remote Controller User Manual
Mirror Download [FCC.gov]Controlled Entry Distributors INOX Remote Controller User Manual
Document ID2769097
Application IDP6dGXw7zgVw3c3KHGmcUDg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize203.3kB (2541304 bits)
Date Submitted2015-10-01 00:00:00
Date Available2015-10-01 00:00:00
Creation Date2015-09-02 11:58:53
Producing SoftwaredoPDF Ver 7.3 Build 391 (Windows 7 Business Edition (SP 1) - Version: 6.1.7601 (x64))
Document Lastmod2015-09-30 11:41:03
Document TitleUsers Manual

CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
TECHNICAL CONSTRUCTION FILE
Marchio
(Brand)
PRODOTTO
Serie
(Product )
(Serie)
INOX
Modelli
(Types)
DOCUMENTO
( Document )
N° PAGINE
(Page Number)
DATA DI RILASCIO
(Date of issue)
TRANSMITTER SOLUTIONS
TCF-162
S9TR2645AM1,
S9TR2645AM2M
FILE
D:\Prodotti\Sistema INOX\Documenti\TX\TCF-162.doc
ALLEGATI
21
(Attachments)
5/8/2015
REVISIONE
(Revision)
Realizzato
Verificato
Approvato
(Performed)
(Verified)
(Approved)
G.M.Dalle Carbonare
L. Braido
G.M.Dalle Carbonare
--------------------------------------------
--------------------------------------------
--------------------------------------------
TCF-162
08/2015
Pag 1 of 21
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
SUMMARY
1.0
Introduction ................................................................................................................... 3
2.0
Technical specifications ................................................................................................ 4
3.0
Mechanical drawings .................................................................................................... 5
4.0
Description.................................................................................................................... 7
5.0
Schematic block diagram ............................................................................................ 11
6.0
Reference regulations ................................................................................................. 12
7.0
Electrical diagrams...................................................................................................... 13
8.0
Component Layout...................................................................................................... 14
9.0
Component list ............................................................................................................ 16
10.0 PCB Boards ................................................................................................................ 18
11.0 PHOTOS .................................................................................................................... 20
TCF-162
08/2015
Pag 2 of 21
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
1.0
Introduction
Transmitter Solutions - Monarch 433 TSPW2KC and is a key-chain 2-buttons transmitter operating
at 433,92 MHz in FSK modulation.
It has been designed for the system INOX USA to lock and unlock by radio of the electronic lock
EL60
The security code, generated by the transmitter, has a rolling system generation: in this way the
code changes at each transmission.
The code has an high security algorithm ( 64 bits – billions of combinations ).
Once received the code, the receiver card inside the EL60 can make the decryption and can lock
or unlock the door.
The serial number of the security code is set in factory by the manufacturer once for ever: it has
been stored into the memory of the corresponding receiver which has a capacity of up of 13 user
rolling codes.
The product fully complies with the FCC Rules cfr 47 part 15.
1.1
Product references
BRAND :
Transmitter Solutions
SERIES :
INOX
TYPES :
S9TR2645AM1, S9TR2645AM2M
MANUFACTURER : CDVI WIRELESS S.p.A.
Via Piave, 23
I-31020 S.PIETRO DI FELETTO ( TV)
ITALY
Tel: +39-0438-450860
Fax: +39-0438-455628
CONTACT : Ing. G. Massimo Dalle Carbonare – Product Manager
TCF-162
08/2015
Pag 3 of 21
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
2.0
Technical specifications
Operating frequency .........................................................433,05  434,790 MHz
Carrier frequency: ..............................................................433,920 MHz
Rated frequency tolerance: ................................................ 100 KHz
Rated E.R.P. ...................................................................1,5 µW
Modulation: .......................................................................FM/ FSK
Modulating signal frequency:..............................................200 kbit/sec
Channel width: ...................................................................> 25 KHz
Power supply: ...................................................................3 Vdc
Battery ...............................................................................CR2032 lithium battery
Security code system ........................................................Keeloq® hopping code
N° of code security combinations: ......................................264
Channel push-buttons: ......................................................1 or 2
Range ................................................................................100 m
Dimensions ........................................................................61 x 36 x 13 mm
Weight ...............................................................................19 g
Antenna .............................................................................Integral
TCF-162
08/2015
Pag 4 of 21
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
3.0
Mechanical drawings
3.1
2-buttons Master external view
DARK
S9TR2645AM2M
3.2
1-button User transmitter external view
S9TR2645AM1
TCF-162
08/2015
Pag 5 of 21
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
3.3
Battery access
Fig. 3a
Fig. 3b
TCF-162
08/2015
Pag 6 of 21
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
4.0
Description
4.1
How to Use the INOX Lock with the RF Receiver
The RF system is composed by:
- A RF receiver with cables for internal connections,
- two USER Tx,
- and one Master Tx.
The RF Receiver can handle max 10 User Tx, and 3 Master Tx.
Master Tx has two pushbutton. Master TX is for maintenance, and cannot open the lock.
“A” button is for ADD menu, “B” button is for DELETE menu.
USER Tx has one pushbutton to open the Lock.
On the RF receiver board there is a Push Button for ADD or DELETE operations.
To access the Push button you have to disassemble the lock.
MASTER Tx
If the Lock is already installed you must use the MASTER Tx.
To control one single Lock by RF at a time, a Magnet has been inside the Master Tx, and a
magnetic switch on the RF receiver, otherwise you may control unwanted locks in the range!
The Master Tx must be placed on the lock, under the keyboard, to be detected and signalled by a
BEEP tone.
“A” Button is to enter the ADD Menu, “B” Button to enter the DELETE_Single_User, or
DELETE_ALL Menu.
You can ADD max 3 MASTER Tx. You cannot REMOVE MASTER, to delete Master you have to
clear all memory - Factory default. The Master Tx are NOT allowed to open the Lock.
TCF-162
08/2015
Pag 7 of 21
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
Operate by a MASTER Tx ,
To operate by a Master Tx , you have to ADD Master at first :
- place the Master on the Lock till the BEEP (magnet detected)
- then press “A” Button for 4 seconds till BEEP to enter in ADD MENU (beep pause-beep-pause…)
- Press again the “A” Button to ADD the Master into the memory of the RF receiver (Long beeppause-beep-pause-beep-pause…).
- The receiver is enabled to add more TX (other Master, and more User) for 15 seconds timeout
(beep-pause-bip-pause…).
When there is at least one Master present into the memory of the Lock, than you can use that
Master to ADD other Master or USER into the memory of the receiver.
ADDING more TX by an already registered Master Tx:
- place the registered Master on the Lock till the BEEP (magnet detected )
- then press “A” Button for 4 seconds till BEEP to enter in ADD MENU (beep pause-beep-pause…)
- The receiver is enabled to add TX (other Master - max 3 total , and more User – max 10 total) for
15 seconds timeout (beep-pause-beep-pause…)
If you try to ADD an already registered TX : nothing will happen , no signaling.
If you try to add more Tx when memory is full, 3 beep will signal the error: beep-beep-beep.
DELETING USER by Master Tx :
- place the Master on the Lock till the BEEP (magnet detected)
- then press “B” Button for 4 seconds till the DOUBLE BEEP to enter in the DELETE MENU (beepbeep-pause-beep-beep-pause…)
- Press the pushbutton of the USER Tx that you want to remove
- The receiver is enabled to REMOVE more USER TX for 15 seconds timeout (beep-beep-pausebeep-beep-pause…)
DELETING_ALL (Factory Default) by Master Tx:
- place the Master on the Lock till the BEEP (magnet detected )
- then press “B” Button for 4 seconds till the double BEEP to enter in DELETE MENU (beep-beeppause-beep-beep-pause…)
- Press again “B” Button to DELETE_ALL (clear all memory to Factory default)
OPERATE BY ON BOARD RECEIVER PUSHBUTTON
By the on board pushbutton you can ADD USER Tx (also with no Master Tx installed) ADD
MASTER Tx or USER Tx
- Press pushbutton till BEEP and release pushbutton immediately
- After 2 seconds it will BEEP again (beep-pause-beep-pause…)
- You can ADD TX (USER or MASTER) for 15 seconds timeout.
TCF-162
08/2015
Pag 8 of 21
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
DELETE ALL TX
- Press pushbutton till BEEP and release pushbutton
- Within 2 seconds press again the pushbutton for 4 seconds till a LONG BEEP.
The Receiver is Factory Restored with clear memory.
TCF-162
08/2015
Pag 9 of 21
CDVI Wireless SPA VIA PIAVE, 23- 31020 S.PIETRO DI FELETTO (TV) – ITALY
Tel. +39.0438.450860 R.A. – Fax. +39.0438.455628
I. 03023780269
internet: www.erone.com - e-mail: info@erone.com
4.2
Rolling code synchronization system
The code transmitted by the transmitted changes at each key activation.
That means that the receiver has to be able to follow the right sequence in order to activate its
outputs.
The code actually transmitted is composed by 3 main blocks:
 a manufacturer key
 a serial number
 a counter number
The manufacturer key is proprietary of the manufacturer and is fixed in each transmitter.
The serial number is characteristic of each transmitter and is set-in-factory by the manufacturer
during the programming of the micro; for this reason, it is different for each transmitter.
The counter number comes from a counter which increments at every activation.
All the above numbers once assembled are encrypted and then sent to the modulator.
The synchronisation system operates as follows:
32768
65525
128
Once the serial number of the transmitter has been stored into the receiver memory, is the counter
number received and the counter number of the receiver differ for less of 128 the receiver updates
its counter and enable the output.
If the difference between the two counter numbers is greater than 128 but less than 32768, the
synchronisation can occur only after 2 consecutive received counter numbers ( that means two
close transmissions without any error of the transmitter).
The device is approved by the FCC and it complies with Part 15 of the FCC Rules.
Its operation is subject to the following 2 conditions:
1. This device may not cause harmful interference.
2. The device must accept any interference that may cause undesired operation.
TCF-162
08/2015
Pag 10 of 21

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2015:09:30 11:41:03+08:00
Create Date                     : 2015:09:02 11:58:53+08:00
Metadata Date                   : 2015:09:30 11:41:03+08:00
Format                          : application/pdf
Document ID                     : uuid:4652abb2-6e42-4e1f-8f6c-ff4e47350378
Instance ID                     : uuid:a667ed85-f667-42d8-968d-5756d11a4dce
Producer                        : doPDF Ver 7.3 Build 391 (Windows 7 Business Edition (SP 1) - Version: 6.1.7601 (x64))
Page Count                      : 10
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SU7INOX

Navigation menu