Cooper Wiring Devices RFTR9605 Z-Wave Plus Wireless Receptacle User Manual

Cooper Wiring Devices Inc Z-Wave Plus Wireless Receptacle

User manual

Download: Cooper Wiring Devices RFTR9605 Z-Wave Plus Wireless Receptacle User Manual
Mirror Download [FCC.gov]Cooper Wiring Devices RFTR9605 Z-Wave Plus Wireless Receptacle User Manual
Document ID3977668
Application IDPPcJIUbgdhBsgo+LNUWUkA==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize64.42kB (805244 bits)
Date Submitted2018-08-24 00:00:00
Date Available2018-08-29 00:00:00
Creation Date2018-06-21 15:20:57
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2018-06-21 15:20:57
Document TitleUser manual
Document CreatorMicrosoft® Word 2010
Document Author: Windows User

INSTALLATION INSTRUCTIONS
WARNING:



Turn OFF circuit breaker or remove fuse(s) and test that power
is off before wiring.
Never wire any electrical device with power turned on. Wiring
the device with power on may cause permanent damage to the
device and void warranty.
If you are not sure about any part of these instructions, please
contact a licensed electrician.
IMPORTANT:
Z-Wave Receptacle will not work or will become damaged if wired
incorrectly and warranty will be voided. Refer to wiring instructions
provided on reverse side.
CAUTION:
Z-Wave Device Network Instructions
This product may be added to a new or existing Z-Wave network.
An Eaton Wiring Devices Z-Wave device has a blue LED, which





Use only with 120V AC 60 Hz.
Do not exceed maximum rating of the Receptacle as indicated on
the device.
Must be installed and used in accordance with electrical codes.
If a bare copper or green ground connection is not available in the
wallbox, contact a licensed electrician for installation.
Use only #14 or #12 copper wire rated for at least 75°C with these
devices. Do not use with Aluminum wire.
will blink when the device is not included in a Z-Wave network.
The LED stops blinking when the device is in a network.
This product works with other Z-Wave products from different
vendors and product categories as part of the same network.
This product is a listening node and it will act as a repeater in the ZWave network. It will perform the repeater function with Z-Wave
NOTES:



The Z-Wave Receptacle is wired directly to the light fixture.
For Multi-location applications (3-Way or 4-Way) the Z-Wave Smart
Accessory Switch (RF9617) or a regular toggle Switch could be used
along with one Z-Wave Receptacle.
The Z-Wave Receptacle communicates via RF signals to control the
load.
products from Eaton and from other Z-Wave vendors.
Adding Z-Wave Receptacle to a Z-Wave Network:
1.
To include this device in a Z-Wave network, select the
command on your Z Wave controller for inclusion (Install,
Add Device, Add Node, Include Device, etc.). Then press
the device ON/OFF button one time to include it in the
network.
Electrical Ratings:
Current Capacity: 15Amps
Horsepower: 1/2HP
Voltage: 120Vac
Frequency: 60Hz
2.
Based on the controller, the controller may ask you to scan
the QR code or manually enter 5 digit code under the QR
code to install the device as a secured device. You may find
this QR code on the device or included in device packaging
3.
After the Device is added to the network, the LED will stop
blinking. This indicates the device is installed in the Z-Wave
network.
Removing Z-Wave Receptacle from a Z-Wave Network:
1.
To exclude this device from a Z-Wave network, select the
setting on your Z-Wave controller for exclusion (Uninstall,
Remove Device, Remove Node, Exclude Device, etc.).
2.
Once your controller is in exclusion mode, press the device
ON/OFF button one time to exclude it from the network. The
LED will start blinking.
For a Quick start Guide on how to install this device with Eaton’s
Home Automation Hub & other compatible Z-Wave Certified
Controllers, please scan the QR code
Operating Instructions:



Press ON/OFF button once to turn lights/load ON
Press ON/OFF button again to turn lights/load OFF.
Indicator Light stays ON at dim level when the Receptacle is OFF to
act as pilot light (this can be turned OFF using following instructions)
Changing LED Indicator brightness:
Configuration parameters:
RFTR9605
Parameter
Description
Value
Delayed Off Time
0 to 255 secs
Panic On Time
0 to 255 secs
Panic Off Time
0 to 255 secs
Power Up State
1=OFF 2= ON
3 = Last State
Panic Mode Enable
0=Off
1=On
13
BLUE LED Brightness
Level while the
Receptacle is ON
0-4
14
BLUE LED Brightness
Level while the
Receptacle is OFF
0-4
This feature allows the change of the brightness of the blue LED
indicators on the device
There are 5 levels (including fully OFF and full brightness) to change
the LED indicator brightness level either while the device is ON or
OFF state.
Changing the LED indicator brightness when the device is
on ON state:





Press On/Off button to Turn the device ON
Press and hold the On/Off button for 15 seconds till the
LED indicator flashes.
Release the On/OFF button
Single tap the ON/OFF button to change the LED
indicator level (it will cycle between the five levels)
Once the brightness level is selected, double tap on the
On/Off button and this value will be saved
Changing the LED indicator brightness when the device is
on OFF state:





Press On/Off button to Turn the device OFF
Press and hold the On/Off button for 15 seconds till the
LED indicator flashes
Release the ON/OFF button
Single tap the ON/OFF button to change the LED
indicator level (it will cycle between the five levels)
Once the brightness level is chosen then double tap on
the On/Off button and this value will be saved
Local Reset
The device could be reset locally. This will cause the device to be
excluded from its network and restore to factory default. Before
leaving the network the device will send a notification to the controller
indicating its departure from the Z-Wave network.




Turn the device ON
Press and hold ON/OFF button for 20 second till the LED flashes for
the second time
Release the ON/OFF button
LED will start flashing rapidly. Once the LED starts blinking slowly,
that indicates the device is not part of the network
The following wiring diagrams are correct, but we need to change the graph to look better
Single Location (RFTR9605)
3-Way with an RF Receptacle (RFTR9605) and a toggle Receptacle
Troubleshooting Guide
Symptom
Device doesn’t function LED is OFF
Device functions normally using the ON/OFF
button but not from Z-Wave controller and the
blue LED blinks ON and OFF about once per
second
Device function normally but can’t add the
device to the Z-Wave network and LED is
blinking
Device functions normally using the
Receptacle push buttons but not from Z-Wave
controller and no LEDs are blinking
Possible Cause
A) Circuit breaker is Open or
tripped
B) Improper wiring
C) Defective Receptacle
B) Check and correct wiring
C) Replace Receptacle
Device is not included in Z-Wave
network
Include device in a Z-Wave network using a
Z-Wave controller. Refer to Z-Wave
controller user manual for installation
instructions
A) The device is far from controller A) Start the installation process with the
devices closer the controller first
B) Not following the instruction of B) Refer to the controller manual
how to add a device to a network
A) Controller can’t communicate to A) Go through Local Reset procedure and rethe device
add the device to the network
Device functions normally both locally and from The accessory or other Z-Wave
a Z-Wave controller but can’t be controlled from device is not associated with the
a accessory Switch (RF9617) or other Z-Wave Receptacle you wish to control
device
Functions normally both locally and from a ZWave controller but can’t be controlled from a
toggle Switch
Solution
A) Turn ON/Close the circuit breaker
Create an association between the
accessory or other device and the
Receptacle. Refer to your Z-Wave controller
user manual for details
The toggle Switch is not wired correctly Check wiring
to the Receptacle
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1: This device may not cause harmful interference, and
2: This device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
FCC CAUTION:
Any changes or modifications not expressly approved by Eaton Wiring Devices could void the user’s authority to
operate the equipment
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the
following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired
operation of the device.
RSS-GEN Issue 4 French Version
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage;
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.
COOPER WIRING DEVICES LIMITED 2 YEAR WARRANTY –(Change for Eaton Version)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 5
Language                        : en-US
Tagged PDF                      : Yes
Author                          : Windows User
Creator                         : Microsoft® Word 2010
Create Date                     : 2018:06:21 15:20:57-04:00
Modify Date                     : 2018:06:21 15:20:57-04:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UH2-RFTR9605