Corbin Russwin Visio Set ED4000/5000 X M94 DK11 BPS 24 1 120860
User Manual: Corbin Russwin ED4000/5000 x M94 x DK11 x BPS 24 1 Wiring Diagrams and Instructions
Open the PDF directly: View PDF .
Page Count: 1
ASSA ABLOY Applications
Web: www.assaabloydss.com Phone: 800-810-WIRE Email: 800810WIRE@assaabloyusa.com Point-To-Point Diagram 06/29/10
Date Drawn By Revision
ASSA ABLOY
Drawing #120860
RLM A
Richard McKeown
ASSA ABLOY Applications
Web: www.assaabloydss.com Phone: 800-810-WIRE Email: 800810WIRE@assaabloyusa.com Point-To-Point Diagram 06/29/10
Date Drawn By Revision
ASSA ABLOY
Drawing #120860
RLM A
Richard McKeown ED4000/5000 x M94 x DK11 x BPS 24 1
To NC
Fire Alarm
Contacts
1181716151413121110
98765432
Black
Red
+
-
Power
Transfe
r
Latch Retraction M94 or P
To battery Negative
To Battery Positive
GNH
+
F
-
+
ACAC
120 VAC Input
BPS-24-1
To NC Fire Alarm
contacts
Battery optional
6
NC
5
C
4
NO
3
REX
2
VDC
NEG
1
12V or
24VDC
DK-11
Wire Gauge Requirements
between 781N
and Latch Retraction Exit
Device:
16 Gauge up to 1' - 40'
14 Gauge up to 40' - 60'
12 Gauge up to 60' - 100' MAX
NOTE: ALL LOW VOLTAGE WIRING TO BE 18
GAUGE MINIMUM STRANDED, EITHER SINGLE
OR MULTI-CONDUCTOR COLOR CODED
WITHOUT SPLICES. (A MINIMUM OF TWO
SPARE CONDUCTORS IS SUGGESTED) ALL
WIRING MUST CONFORM TO NATIONAL,
STATE, AND LOCAL CODES FOR CLASS 2 FIRE
PROTECTION AND CONTROL DEVICES.