Corbin Russwin Visio Set ED4000/5000 X M94 6900 Powermatic 2 Wall Plates By MKA Key Switch To Disable Exterior Actuator 120862

User Manual: Corbin Russwin ED4000/5000 x M94 x 6900 Powermatic x 2 Wall Plates By MKA Key Switch to Disable Exterior Actuator Wiring Diagrams and Instructions

Open the PDF directly: View PDF PDF.
Page Count: 1

ASSA ABLOY Applications
Web: www.assaabloydss.com Phone: 800-810-WIRE Email: 800810WIRE@assaabloyusa.com Point-To-Point Diagram 06/28/10
Date Drawn By Revision
ASSA ABLOY
Drawing #120862
RLM A
Richard McKeown
To NC
Fire Alarm
Contacts
1181716151413121110
98765432
Black
Red+
-
Power Transfer
Latch Retraction M94
660 wall
Switch 660 wall
Switch
14
7
1
6
5
4
3
2
8
9
10
11
12
13
JP4 TERMINAL
STRIP
GRD 24
VDC NO
1NC
1
COM
1NO
2COM
2NC
2
87654321
JP 1 Terminal Strip
NGrd
Hot
120 VAC
Input
13 & 14 Input for
actuators
NOTE: ALL LOW
VOLTAGE WIRING TO BE
18 GAUGE MINIMUM
STRANDED, EITHER
SINGLE OR MULTI-
CONDUCTOR COLOR
CODED WITHOUT
SPLICES. (A MINIMUM OF
TWO SPARE
CONDUCTORS IS
SUGGESTED) ALL WIRING
MUST CONFORM TO
NATIONAL, STATE, AND
LOCAL CODES FOR
CLASS 2 FIRE
PROTECTION AND
CONTROL DEVICES.
6900 PowerMatic Operator
ED4000/5000 x M94 x 6900 Powermatic x 2 Wall Plates
By MKA Key Switch to Disable Exterior Actuator
Wire Gauge Requirements
between 781N
and Latch Retraction Exit
Device:
16 Gauge up to 1' - 40'
14 Gauge up to 40' - 60'
12 Gauge up to 60' - 100' MAX
Interior Exterior
C White
NC Red
NO Blue
MKA2
GreenRed
Black GRD
NC Red
NO Blue
C White
NOTE: ALL LOW VOLTAGE WIRING TO BE 18
GAUGE MINIMUM STRANDED, EITHER SINGLE
OR MULTI-CONDUCTOR COLOR CODED
WITHOUT SPLICES. (A MINIMUM OF TWO
SPARE CONDUCTORS IS SUGGESTED) ALL
WIRING MUST CONFORM TO NATIONAL,
STATE, AND LOCAL CODES FOR CLASS 2 FIRE
PROTECTION AND CONTROL DEVICES.