Core TP72013 Touch Panel User Manual 9901341 Rev B Universal TP7 QSG 0730 PRINT indd
Core Brands, LLC Touch Panel 9901341 Rev B Universal TP7 QSG 0730 PRINT indd
Core >
(TP7) UserMan
Job: Universal Manual Size: 150 x 150 mm folded 07/30/2014 -> Final print pdf Folding-Method: ELAN & Niles & SpeakerCraft Quick Install Guide – TP7 8 pages each - Format: 150 x 300 mm ( Metric !! ) 300 TP7 – 7” Touch Panel User Interface Quick Install Guide English Final Print pdf / Rev B English only 150 150 150 150 Folded size: 150 x 150 mm Open: 600 mm wide x 300 mm high No bleed 07/30/2014 - WE Questions? Juergen 707 - 778 - 5826 P/N 9901341 REV. B 07/2014 TP7 – 7” Touch Panel User Interface Quick Install Guide English 9901341_Rev-B_Universal_TP7_QSG_0730_PRINT.indd 1-4 7/30/14 9:59 AM 2 Powering up the TP7 Once installation is complete, press the Power button located on top of the TP7 and allow the unit to boot up. Setting screen orientation Important Safety Instructions The TP7 is shipped pre-configured for landscape orientation. 1. Read, understand and follow ALL safety and installation instructions included in this manual. Failure to follow the included documentation may damage the product and will void manufacturer’s warranty. 2. Follow ALL installation guidelines included with the product. Installation of the product in high humidity environments, in close proximity to heat sources and /or non-recommended locations WILL impede, interfere and/or damage the intended operation of the product 3. Only use attachments and accessories which have been specified for use by the manufacturer. 4. The use of abrasive, liquid or solvent based cleaning fluids WILL damage the product. Please refer and follow all Product Care instructions included with the product. 5. Product Servicing may ONLY be completed by authorized or certified service centers & personnel. For a complete list of product servicing options, please follow instructions included in the product documentation and /or contact original manufacturer for details. To change orientation: - If connected to a wired Ethernet switch the TP7 will aquire a network address via DHCP and automatically connect to the system. – Tap the POWER button 10 times in quick succession – Follow the on-screen instructions to re-orient the screen - If the TP7 does not detect a wired Ethernet connection and the WiFi radio has never been configured you will be presented with the Network Configuration Utility interface. To complete the network configuration please refer to the most current training documentation for your system. Power FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/ TV technician for help. TP7 – 7” Touch Panel User Interface Quick Install Guide English Removing the TP7 – Using two hands grasp it on each side or the top and bottom and pull straight out from the wall. It will require approx. 10lbs of force to remove it from the bracket. RESET FCC and IC Information: This Class B digital apparatus complies with Part 15 of the FCC rules and with Canadian ICES-003 and RSS-210. The recessed RESET button has two functions – A tap of the button will reset all network configuration – Press and hold the button for 15 seconds completely restores the factory default settings. Mounting Bracket Mounting Bracket Top of 2 Gang Box Cet appareil numérique de classe B est conforme aux normes canadiennes ICES-003 et RSS-210. Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer d’interférence et (2) cet appareil doit accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement. CAUTION: Neither of these actions can be reversed. Dry Wall Operation is subject to the following two conditions: 1. This device may not cause interference and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Recessed Reset Switch Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC and IC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the exemption from the routine evaluation limits in section 2.5 of RSS 102. TP7 Frame Recessed Reset Switch Thank you for including the TP7 as part of the user interface strategy for your customer. The TP7 has been designed to provide years of trouble free operation when wired and installed properly. The TP7 has been designed for installation in low humidity indoor environments and should never be installed outdoors or in high humidity areas. Included in the box • 1ea TP7 touch panel • 1ea TP7 mounting bracket • 4ea Mounting screws • 1ea DC power connector Introduction To install the TP7 you will also need a standard 2 gang US junction box or low voltage bracket. Informations concernant l’exposition aux fréquences radio (RF): La puissance de sortie émise par l’appareil de sans fil est inférieure à la limite `exposition aux fréquences radio d’Industry Canada (IC). Utilisez l’appareil de sans fil de façon à minimiser les contacts humains lors du fonctionnement normal. Ce périphérique a également été évalué et démontré conforme aux limites d’exposition aux RF d’IC dans des conditions d’exposition à des appareils mobiles (antennes sont supérieures à 20 cm à partir du corps d’une personne). Paper Clip Overall 8”w x 5”h Mounting Depth 1 ¾” Microphone Dual Digital Beam Forming Far Field Pickup Speaker 2w integrated Camera 640 x 480 Display 7” 800 x 480 Network 10/100 Ethernet 802.11 B/G/N WiFi RJ-45 2 pin Phoenix USB Type A 1/8” stereo (Future Use) Power Requirements Direct – 12v DC 350mA PoE – IEEE 802.3at, 13w maximum draw (@44 V /350 mA max) Warning: The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102, and users can obtain Canadian information on RF exposure and compliance from the Canadian Representative Product Solutions Group at Tel: (519) 763-4538. © 2014 Core Brands, LLC. All rights reserved. Core Brands, LLC, a Nortek company. 9901341_Rev-B_Universal_TP7_QSG_0730_PRINT.indd 5-8 Dimensions Connections LAN/PoE Power USB Audio Out 1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters from user and bystanders. LAN + Power over Ethernet Specifications P/N 9901341 Rev. B 07/2014 7/30/14 9:59 AM TP7 – Overview b. Rough-In e. Installing the TP7 Bracket 12v Power Supply The TP7 has been designed to mount to a US standard 2 gang box or low voltage bracket. – The TP7 includes a mounting bracket that MUST be used. Using the included screws mount the bracket onto the 2 gang box or low voltage bracket and verify that the bracket is level before tightening the screws. – By utilizing a 12v power supply (not included) to power the TP7 you may provide power locally or remotely. If powering locally be sure to run the wire through the wall in accordance with local codes. If powering remotely be sure to use wire of adequate gauge for the length of the run. Camera Power Microphone Status LED - The TP7 is “snap” fit into the box/bracket and requires approximately 10lbs of force to remove it from the wall. Ensure that the mounting method you are using is compatible with these requirements. Proximity Sensor – The mounting bracket is designed to level out uneven wall surfaces allowing the TP7 to fit securely on most any surface. Note that uneven surfaces will create a gap between the back of the panel and the wall – this is normal. Do not tighten the mounting bracket so as to distort it’s shape as this will create issues with properly seating the TP7 in the bracket. – Verify the polarity of your power supply prior to termination and ensure the power supply is not connected to a power source. – Strip approx. ¼” of insulation from the wire and observing the correct polarity, terminate the wire into the supplied connector and tighten firmly. Be sure to twist the wires before inserting so that no strands escape the connector. Inspect the termination to verify that the wire is securely retained by the connector and no strands have escaped the barrier. Speaker – Plug the connector into the TP7. F-2 Front of Mounting Bracket Old Work Box New Const. Box Back of TP7 Recessed Reset Switch TP7 Touch Panel USB Phoenix Type Connector Recessed Reset Switch DC Power Input Line in wall LAN + Power over Ethernet Audio Out (Future Use) New Const. Low Volt Bracket Old Work Low Volt Bracket Planning the installation c. Landscape Mounting f. Connecting the TP7 to power The TP7 is designed to wall mount in either Portrait or Landscape orientation. Ensure there is adequate wall space for the TP7 and that the surface is relatively smooth. – Install the 2 gang box or bracket in it’s normal orientation – with mounting screw holes at the top and bottom. The box is exactly centered with the touch panel for your convenience. – The TP7 is designed to be powered over the Ethernet connection (PoE) or by connecting a 12v power supply (not included), but not both. If both the PoE and a 12v power supply are connected the TP7 will draw power from the 12v source. The TP7 requires a minimum mounting depth of 1 ¾” (4.5 cm) from the front surface plus room for wire. Ensure that adequate depth is available. Power 2 Gang Box F-1-A Power may be supplied by Power Over Ethernet (PoE) or by a 12v DC power supply (not included). PoE must meet the IEEE 802.3af standard. Direct power via a 12v DC external power supply requires a minimum current output of 350mA. TP7 The TP7 connects to the local network via Ethernet or Wi-Fi. When utilizing Wi-Fi you must ensure that there is adequate Wi-Fi coverage at the mounting location. Installing the TP7 d. Portrait Mounting a. Mounting height – Install the 2 gang box or bracket rotated 90° - with the mounting screw holes on the left and right sides. The box is exactly centered in the touch panel for your convenience. – Depending on how tall your homeowner is, it is recommended to locate the center of TP 7 between 57”- 65” (145 cm -165 cm) above the finished floor. g. Connecting Ethernet PoE Connection h. Mounting the TP7 – Connect the TP7 using a standard T568A or T568B Ethernet cable from the network switch to the LAN/PoE jack. If you have terminated your own CAT 5e/6/7 cable use a tester to ensure that both ends have been properly terminated. – Orient the TP7 with the POWER button at the top right for landscape mounting or the top left for portrait mounting. To TP7 – The TP7 is held into the mounting bracket by spring steel tabs. – To complete the installation simply grasp the TP7 on the edges and press firmly on to the bracket until it is seatled. CAUTION: DO NOT PRESS DIRECTLY ON THE SCREEN when installing on to the mounting bracket. Press only on the frame edges. F-1-B PoE Injector 2 Gang Box Mounting Bracket Network Switch 165 cm / 65” TP7 TP7 Touch Panel PoE Network Switch 9901341_Rev-B_Universal_TP7_QSG_0730_PRINT.indd 9-12 – Utilizing a T568A or T568B network cable connect to the LAN/PoE jack. If you have terminated your own CAT 5e/6/7 cable use a tester to ensure that both ends have been properly terminated. – PoE connection requires that IEEE 802.3af standard (13w maximum draw @44 VDC/350mA max) is met. Utilize a network switch or PoE injector that meets this standard. Power 145 cm / 57” – When not utilizing PoE, but you have a physical network connection available it is recommended that you connect the TP7 directly to the network switch. Top of 2 Gang Box Mounting Bracket Dry Wall TP7 Frame 7/30/14 9:59 AM
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2014:07:30 09:59:47-07:00 Metadata Date : 2014:07:30 09:59:50-07:00 Modify Date : 2014:07:30 09:59:50-07:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:c29253c7-c420-6848-b737-5563b396285f Original Document ID : xmp.did:F87F1174072068118083FE3317B94A6B Document ID : xmp.id:B0AE54250F2068118083BD219B2DB9AD Rendition Class : proof:pdf Version ID : 1 Derived From Instance ID : xmp.iid:AEAE54250F2068118083BD219B2DB9AD Derived From Document ID : xmp.did:B34C82430C2068118083BD219B2DB9AD Derived From Original Document ID: xmp.did:F87F1174072068118083FE3317B94A6B Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2014:07:30 09:59:47-07:00 Format : application/pdf Title : 9901341_Rev-B_Universal_TP7_QSG_0730_PRINT.indd Producer : Adobe PDF Library 10.0.1 Trapped : False GTS PDFX Version : PDF/X-1:2001 GTS PDFX Conformance : PDF/X-1a:2001 Page Count : 3 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools