Cornelius Intellicarb Cold Beverage Dispenser Users Manual

IntelliCarb Cold Beverage Dispenser 007027

Cold Beverage Dispenser to the manual 46ef5bc9-d3bf-4257-81a4-40fdad2f63c4

2015-02-05

: Cornelius Cornelius-Intellicarb-Cold-Beverage-Dispenser-Users-Manual-533838 cornelius-intellicarb-cold-beverage-dispenser-users-manual-533838 cornelius pdf

Open the PDF directly: View PDF PDF.
Page Count: 48

INTELLICARB
Training Manual
Release Date: April 29, 2004
Publication Number: TP01071
Revision Date: NA
Revision: A
Visit the IMI Cornelius web site at www.cornelius.com for all your Literature needs.
®
INTELLICARB TRAINING MANUAL
The products, technical information, and instructions contained in this manual are subject
to change without notice. These instructions are not intended to cover all details or varia-
tions of the equipment, nor to provide for every possible contingency in the installation,
operation or maintenance of this equipment. This manual assumes that the person(s)
working on the equipment have been trained and are skilled in working with electrical,
plumbing, pneumatic, and mechanical equipment. It is assumed that appropriate safety
precautions are taken and that all local safety and construction requirements are being
met, in addition to the information contained in this manual.
To inquire about current revisions of this and other documentation or for assistance with
any Cornelius product contact:
www.cornelius.com
800-238-3600
Trademarks and copyrights:
Aurora, Cornelius, Decade, Hydro Boost, Sitco, Spirit, UF-1, Vanguard, Venture, Olympus,
and Vista are registered trademarks of IMI Cornelius Inc.
Optifill trademark is pending.
This document contains proprietary information and it may not be
reproduced in any way without permission from Cornelius.
Printed in U.S.A.
Copyright © 2004, All Rights Reserved, IMI Cornelius Inc.
InelliCarb Training Manual
© 2004, IMI Cornelius Inc. - i - Publication Number: TP01071
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Unit Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Delivery Inspection and Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Drains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Cornelius IntelliCarb Carbonator Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Carbonator Time Out Reset Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Carbonator Relief Valve Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Mechanical Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Gate Restrictor Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Ice Diverter Kit 02394 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Removal and Replacement of Agitators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
To Remove Agitators For Cleaning (300 shown) . . . . . . . . . . . . . . . . . . . . . . . .10
Post-Mix Valve Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Set-up Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Dimensions & Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
System Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Water Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Water Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Adjusting Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Calculating Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Syrup/Concentrate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Setting Ratios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Shurflo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Shurflow Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Shurflow Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Start-up Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Plumbing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Plumbing Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Flow Diagram 1xx (Six Flavor Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Flow Diagram 1XX (Eight Flavor Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Flow Diagram 2xx (Eight Flavor Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Flow Diagram 2xx (Ten Flavor Models)) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Flow Diagram 300 (Twelve Flavor Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
IntelliCarb Training Manual
Publication Number: TP01071 - ii - © 2004, IMI Cornelius Inc.
Electrical Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Carbonator Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Wiring Diagram 1xx (120V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Schematic 1xx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Wiring Diagram 2xx (120V Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Wiring Diagram 2xx (220/240V Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Wiring Diagram 2xx (220/240V Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Wiring Diagram 300 (220/240V Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Wiring Diagram 300 (220/240V Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Schematic 300 (120V Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Schematic 300 (220/240V Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
SHURflow Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Pumping Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Pumps in Series for Long Distances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Pump Sanitizing / Winterizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Pump Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
DOES NOT OPERATE / GAS APPLIED / DISPENSER VALVE OPEN . . . 37
OPERATES BUT WILL NOT PRIME / DISPENSER VALVE OPEN . . . . . . 37
DOES NOT ACHIEVE SOLD-OUT WITH EMPTY B-I-B . . . . . . . . . . . . . . . 37
AIR IN INLET AND/OR OUTLET TUBING . . . . . . . . . . . . . . . . . . . . . . . . . . 37
STROKES WITH DISPENSER VALVE CLOSED . . . . . . . . . . . . . . . . . . . . 37
FLUID FROM EXHAUST OR VISIBLE WITHIN GAS INLET TUBING . . . . . 37
GAS BLOWING FROM EXHAUST CONTINUOUSLY . . . . . . . . . . . . . . . . . 37
Dispenser Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Valve Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Excess Foam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Off Taste . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Valve Stuck Open . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
No Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Carbonator Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Solid State Carbonator Level Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Test Solid State Level Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
InelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 1 - Publication Number: TP01071
INTRODUCTION
UNIT DESCRIPTION
Built-in cold carbonator produces bottle-quality drinks every time
No seasonal CO2 adjustments required for changes in water temperature
A complete system for simplified installation
Reduces service frequency and lowers equipment life cost
Generates increased beverage sales and greater consumer satisfaction
Illuminated merchandiser delivers unique, high impact marketing message
Ice used to cool cold plate kept separate from ice dispensed into cups
One piece ABS thermoformed plastic ice storage hopper. Durabide design provides durability and
ensures all ice in the hopper is dispensable
Unit readily accepts top mount cubers with manual ice fill capability
THEORY OF OPERATION
The rate of CO2 solubility increases with cold water. IntelliCarb System provides prechilled cold water
from the cold plate and mix with CO2 in the carbonator tank. The water is introduced into the tank with a
high volume 125gph Procon pump and high torque motor.
The amount of carbonated water reserve is controlled by a probe mounted in the tank. The probe is
called a liquid level probe. The liquid level probe senses the water level in the tank. Probe controls the
pump ON and OFF cycle through the electronic board called liquid level board.
NOTE: The probe works on a 5 M.V. D.C. current that continually reverses direction to prevent
probe corrosion.
DESCRIPTION
The Enduro IntelliCarb series of ice dispensers solves your ice and beverage service needs in a
sanitary, space saving, economical way. Designed to be automatically filled with ice from a top mounted
ice machine or manually filled with ice from any remote ice-making source, these dispensers will
dispense cubes (up to 1-1/4 inch in size), cubelets, and hard-chipped or cracked ice. In addition, the units
include beverage faucets, a cold plate, an internal carbonator tank and an external pump for the
carbonator, and are designed to be supplied direct from syrup tanks with no additional cooling required.
IMPORTANT: For dispensing compressed or extruded style ice, an Ice Diverter Kit must be installed on
the dispenser, see FIGURE 13 on page 9.
IntelliCarb Training Manual
Publication Number: TP01071 - 2 - © 2004, IMI Cornelius Inc.
SPECIFICATIONS
REQUIREMENTS
Weight: counter must be level and able to support 450 lbs.
Environment: Indoor installation only
Temperature: 40 to 100oF
CO2: 75 psi at unit
Syrup: 60 psi., 0.70 -- 0.75 ounces per sec. (0.6 gpm) at unit
Water: 60 psi at pump
Electrical: See name plate
DELIVERY INSPECTION AND UNPACKING
Upon delivery inspect the unit for damage or irregularities and immediately report problems to the
delivering carrier and file a claim with that carrier.
Open loose parts packages and inspect parts.
ED150 ED175 ED200 ED250 ED300
Model
Descriptions:
B=(Beverage)
C=(Coldplate)
H=(Internal
Carb)
Z=(No DripTray)
B=(Beverage)
C=(Coldplate)
H=(Internal
Carb)
Z=(No DripTray)
B=(Beverage)
C=(Coldplate)
H=(Internal
Carb)
Z=(No DripTray)
B=(Beverage)
C=(Coldplate)
H=(Internal
Carb)
Z=(No DripTray)
B=(Beverage)
C=(Coldplate)
H=(Internal
Carb)
Z=(No DripTray)
Ice Storage: 150 Pounds 175 Pounds 200 Pounds 250 Pounds 300 Pounds
Maximum
Number of
Faucets
Available:
6 8 10 10 12
Built-in Cold
Plate:
Yes Yes Yes Yes Yes
Electrical:
$PSV7RWDO8QLW'UDZ 120/1/60, 3.5 Amps Total Unit Draw
230/1/50, 2.0 Amps Total Unit Draw 120/1/60, 4.0
Amps Total Unit
Draw
230/1/50, 3.0
Amps Total Unit
Draw
Outlet should be within 6 feet of dispenser.
Dimensions:
Width 22
Deep 30--11/16
High 35--5/8
Z--Models
Width 22
Deep 23--1/16
High 35--5/8
Width 24.5
Deep 30--11/16
High 35--5/8
Width 24--1/2
Deep 23--1/16
High 35--5/8
Width 22
Deep 3011/16
High 355/8
ZModels
Width 22
Deep 231/16
High 355/8
Width 24.5
Deep 3011/16
High 395/8
Width 241/2
Deep 231/16
High 395/8
Width 443/8
Deep 311/2
High 37
ZModels
Width 443/8
Deep 231/16
High 37
CO2 Operating
Pressure
75--psig (max) 75--psig (max) 75psig (max) 75psig (max) 75psig (max)
Part No. Description Qty.
710000030 Pump and Motor Assy 1
70970 4Legs 4
70750 Clamps 2
620702201 Brush 1
51774 Drain Pan Drain Line 1
50335 Drain Line Insulation 1
 )LWWLQJ6RF[)SW 1
 )LWWLQJ0SW[µ%DUE 1
InelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 3 - Publication Number: TP01071
INSTALLATION
1. Locate the dispenser indoors on a level counter top.
A. LEG OPTION
Unpack the four (4) legs and install them into the threaded holes provided in the bottom of the
unit. The installer must provide flexibility in the product and utility supply to permit shifting the
position of the dispenser sufficiently to clean the area beneath it.
B. COUNTER MOUNTING
If counter mounted the ice drink dispenser must be sealed to the counter. The template drawing
indicates where openings can be cut in the counter. Locate the desired position for the dispenser,
then mark the outline dimensions on the counter using the template drawings. Cut openings in
counter.
Apply a continuous bead of NSF International (NSF) silastic sealant (Dow 732 or equal) approxi-
mately 1/4--inch inside of the unit outline dimensions and around all openings. Then, position the
unit on the counter within the outline dimensions. All excess sealant must be wiped away immedi-
ately.
2. The beverage tubes, drain tube and power cord are routed through the large opening in the bottom
of the unit. See the mounting template for locating the required clearance opening in the counter for
these utility lines.
3. Drip tray assembly: Route the drain tube to an open drain with the end of the tube above the flood
level of the drain. Use the tubing, fittings, clamps, and insulation provided with the Dispenser to
assemble the drain. The completed drain line must pitch continuously downward and contain no
traps or improper drainage will result. Must have a 4 inch air gap between drain line and drain.
NOTE: This equipment must be installed with adequate backflow protection to comply with fed-
eral, state, and local codes.
NOTE: IMI Cornelius Inc. recommends that a water shutoff valve and water filter be installed in
the plain water inlet supply line. A Cornelius Water Filter (P/N 313860000) and QUICK DISCON-
NECT SET (P/N 313867000) are recommended.
CAUTION: Check the minimum flow rate and the maximum pressure of the plain water inlet supply line.
MINUMUM FLOW RATE MUST BE AT LEAST 125--GALLONS PER HOUR. If flow rate is less than 125-
-gallons per hour, starving of the carbonator water pump will occur. Starving will damage the water pump
and could cause the carbonator to time out. INCOMING PLAIN WATER INLET SUPPLY LINE WATER
TO PUMP PRESSURE MUST REMAIN A MINIMUM OF 10--PSI BELOW THE CARBONATOR CO2
OPERATING PRESSURE. (Example: Carbonator CO2 operating pressure is 75--PSI and the maximum
water pressure can be no more than 65--psi, etc.). Water over pressure (higher than CO2 operating pres-
sure) can cause carbonator flooding, malfunction, and leakage through the carbonator relief valve. If
water is exceeding maximum pressure specifications, a Water Pressure Regulator Kit (P/N 310150000)
or equivalent must be installed in the plain water inlet supply line. If fitting connector is not available,
water line must be 1/2 or 3/4 diameter with a shut off valve within 6 feet of the dispenser.
4. Locate the carbonator pump assembly and connect probe wires from Ice/Drink Unit and pump. Con-
nect inlet water to pump and pump outlet to Ice/Drink Unit using 3/8--inch food--grade tubing.
NOTE: Locate carbonator assembly within 6 feet of the dispenser. Do not lengthen the control
board harness.
5. Connect the beverage system product tubes as indicated in applicable Plumbing Flow Diagram, see
page 19. This work should be done by a qualified service person.
NOTE: Water pressure for non carbonated beverages must be 60 P.S.I. minimum.
NOTE: See applicable Flow Diagram or Decal on the lower front of the unit for the location of
syrup and water connections.
6. Clean the hopper interior.
7. Connect the two power cords to a 120 volt, 60 cycle, 3-wire grounded receptacle. For 220--240 Volt
International Units, a 3--wire power cord is provided. An adapter plug for the particular country will
need to be provided by the Installer.
IntelliCarb Training Manual
Publication Number: TP01071 - 4 - © 2004, IMI Cornelius Inc.
Drains
Use a 1 - 1/2 rigid pipe (e.g. ABS on P.V.C.) this is to prevent kinking or collapsing. Make sure to leave a
4 inch air gap between the drain line and the floor drain.
CORNELIUS INTELLICARB CARBONATOR ASSEMBLY
1. Ice Drink / Drop-In Carbonator Pump & Motor Unit
FIGURE 1
Carbonator Time Out Reset Switch
The board can be set to turn the carbonator off after three or seven minutes of continuos time. The fea-
ture can also be disabled. See the carbonator instruction in this manual.
FIGURE 2 FIGURE 3
1. Locate carbonator assembly below dispenser no more than 6 feet away. Important: Make
sure there is clearance for the liquid level control reset switch on the side of the control box
to avoid accidentally tripping the switch. The control board has an internal timer to prevent the
pump motor from running continuously. In the event of a water supply interruption or malfunction of
the water level probe and/or motor relay circuit. If there is a time-out event, make necessary repairs
to what caused the time out, then depress and release the reset switch to put the control board
back in service. By moving a jumper on the control you can select either a 7 minute or 3 minute time
out or this feature can also be disabled.
A. Hook-up a 3/8 ID water supply line 125 G.P.H. minimum (60 psig. max.) to pump inlet. Minimum
flowing pressure is 30 psig. Important: Tap for non-carb water supply must be upstream of
pump inlet. Do not tap in the pump outlet.
B. Hook-up a 3/8 (.375 ID) CO2 supply line (100 psig.) to the inlet of the pre-set CO2 regulator (75
psig.) on the Pump & Motor base. Note: If using a bulk CO2 tank as supply, tank pressure
regulator must be set to 100-105 psig. The regulator on the bulk tank should be a second-
ary.
Vent to Atmosphere Check Valve
125 G.P.H. ProCon Water Pump
High Torque Pump Motor
Liquid Level Control Box
Preset CO2 Regulator (75P.S.I.)
Time Out
Selector Pins
Liquid Level
Control Board
Carbonator
Time Out Reset
Switch
InelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 5 - Publication Number: TP01071
C. Initial start-up procedure for carbonated water system: Turn on the CO2 supply to the car-
bonator tank, vent air from carbonator tank by pulling the tank relief valve. Turn on water supply to
the pump. Connect electrical power to the pump and motor unit. Bleed the air out of the system
by energizing a beverage valve until carbonated water is flowing from the valve.
NOTE:If the carbonator Pump and Motor does not cycle (turn on and off) properly, check that the
probe harness connector and ground lead are secured to the carbonator tank connection points.
D. If service is required on Ice Drink units, it will be necessary to lower the beverage valve panel to
gain access to the probe and ground connection. Remove the lower front panel (2 screws) from
the cabinet and the ice chute cover (snap fit). Remove the 6 screws that secure the beverage
panel to the cabinet. The panel can now be moved downward due to the flexibility of the beverage
tubing to expose the carbonator tank connections.
Carbonator Relief Valve Locations
The carbonator tank is located behind the splash panel, on the right side of the dispenser. You will need
to pull the relief valves to purge air from the system after the CO2 supply has been hooked up. Failure to
do this will cause low carbonation volume and popping of the relief valves.
FIGURE 6 FIGURE 7
2. Dispenser
Ice Drink Model ED175BCH (Lower Front Panel Removed)
FIGURE 8
Relief
Valve Ring
Agitator
Motor
Carbonator
Tank
Carbonator
Tank Relief
Valve
Cold Plate Inlets
(3/8 Barb)
Carb. Tank Liquid
Level Probe Harness
Total Flex Manifold
(with insulation)
Carb Tank CO2
Supply Line
Total Flex Manifold
(insulation removed)
Insulated Cold Plate
Cover & Carbonator
Tank Assembly
IntelliCarb Training Manual
Publication Number: TP01071 - 6 - © 2004, IMI Cornelius Inc.
Ice Drink Model ED150/175/300 Coldplate Cover
FIGURE 9
Ice Drink Model ED200/250 Coldplate Cover
FIGURE 10
3. Total Flex System for Ice Drink Models ED150/175/200/250/300
Total Flex Manifold (Insulation Removed)
FIGURE 11
Total Flex is a system of water manifold blocks located at the front of the cold plate, adjacent to the cold
plate inlets, for easy switch over of carbonated / non-carbonated beverage drinks. The right hand mani-
fold block is for the beverage valves located to the right side of the ice chute, and the left block is for the
left bank of valves. Each beverage valve on the dispenser can be set up for either carbonated or non-car-
bonated drinks. Refer to the units plumbing diagram for the factory carbonated / non-carbonated valve
locations. The procedure for switching carbonated / non-carbonated water lines on a beverage valve is
as follows:
A. Shut off the water supply to the dispenser. Depressurize and drain both the carbonated and non-
carbonated water circuits.
B. Remove the retainer clip (2 screws) from the manifold block. Switch the plug and water line fitting
to their respective carbonated / non-carbonated outlet locations on the block.
C. Replace the retainer clip. Turn on the water supply and energize the switched valve(s). Check
for water leaks.
4. Important: Route the dispensers drain line to an open drain with the end of the tube above the flood
level of the drain. The drain line must pitch downward and contain no traps.
5. Connect both the carbonator pump and motor unit and the dispenser to a grounded electrical sup-
ply outlet.
Liquid Level Probe CO2 Check Valve with Ground Stud In-line CO2 Check Valve Ground Plate/Stud
Probe
Plugs
Retainer Clip
Water Line
Manifold Block
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 7 - Publication Number: TP01071
6. Check list for proper “finished” drink carbonation:
A. Fill ice storage hopper with ice.
B. Water supply must be from a continuous source (no tank supply).
C. Use only filtered water.
D. Supply water line to the carbonator pump must be a minimum of .375 ID.
E. Syrup supply lines must be a minimum of .265 ID.
F. Water inlet pressure range: 45-60 max. static psig. with a minimum flowing pressure of 30 psig.
G. Syrup CO2 secondary regulator pressure set to 60 psig.
H. CO2 supply must be high quality, food grade.
I. Purge all water, carb-water, and product lines of air before brixing valves.
J. Important: Brix valves with cold product. Allow at least 15-20 minutes for ice to cool down the
coldplate on initial start-up before brixing the valves.
K. Dispense at least (2) 12 oz. drinks before taking a carbonation level reading.
L. Carbonation tester thermometer must read 32-33oF. for accurate carb-level reading. Store tester
in ice water bath during use.
M. Hold cup at valve nozzle for drink to be tested. Pour drink slowly down the side wall into the carb-
tester to avoid agitation during pouring. Press vent valve once on carb-tester after tightening lid.
N. Shake carb-tester in vertical motion until peak pressure reading is obtained. Use Pepsi chart for
carbonation level reading.
NOTE: Carbonator troubleshooting procedure located on page 43.
IntelliCarb Training Manual
Publication Number: TP01071 - 8 - © 2004, IMI Cornelius Inc.
MECHANICAL SECTION
GATE RESTRICTOR PLATE
NOTE: Disconnect power to dispenser before installing, removing, or adjusting restrictor.
FIGURE 12
Adjustment
This plate may be adjusted as shown to reduce or increase the dispensing rate of ice, especially
desirable when using glasses or other containers with small openings. Adjustment can be made by
sliding up or down with nuts loosened, to obtain the desired amount of restriction.
ADJUSTMENT
INSTALL PLATE
ON STUDS AS
SHOWN
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 9 - Publication Number: TP01071
ICE DIVERTER KIT 02394
NOTE: For dispensing Scotsman, Wilshire, and Hoshizaki compressed ice cubes:
1. Disconnect power to dispenser.
2. Remove Merchandiser from dispenser.
3. Remove ice chute and discard gate restrictor.
4. Install ice diverter on gate mounting plate as shown below.
5. Apply RTV to back surface of ice diverter, to seal to gate mounting plate.
6. Reinstall gasket and ice chute.
7. Reinstall merchandiser and energize unit.
FIGURE 13
IC E C HUT E
IC E C HUT E
COVER
GATE MOUNTING PLATE
GASKET
STORAGE HOPPER
IC E DIVE R T E R
10--32 WA S HE R
10--32 NUT
APPLY RTV TO
THIS SURFACE TO
SEAL TO HOPPER
GATE MOUNTING
PLATE
FLANGE EXTENDS
INTO S TOR AG E HOP -
PER THROUGH GATE
OPENING
IntelliCarb Training Manual
Publication Number: TP01071 - 10 - © 2004, IMI Cornelius Inc.
REMOVAL AND REPLACEMENT OF AGITATORS
To Remove Agitators For Cleaning (300 shown)
NOTE: All other models have only one agitation Assembly.
FIGURE 14
1. Lift agitator and disc from unit.
2. Remove O-Ring starting at notch. Warm the O-Ring with water to ease removal.
3. Lift the plastic agitator disc off of the stainless-steel agitator.
4. Replace by reversing steps.
NOTE: Refer to Sanitize Procedure in the Owners Instruction for complete cleaning and sanitiz-
ing instructions.
LEFT HAND
AGITATOR
O–RING
FRONT (VALVE SIDE) VIEW FROM TOP OF DISPENSER
RIGHT HAND AGITATOR
WITH HOLE IN UPRIGHT
COUNTERCLOCKWISE
ROTATION
CLOCKWISE
ROTATION
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 11 - Publication Number: TP01071
POST-MIX VALVE SECTION
SET-UP INSTRUCTIONS
FIGURE 15
A side water lever kit can be added to a valve allowing for
dispensing of water without syrup or concentrate. The side
water lever can be added to either a carbonated drink valve
or a noncarbonated drink valve.
Post-mix valves control:
the ONOFF of syrup and water,
the flow rates of syrup and water,
the mixing of the two ingredients as they pour into the
cup, and
in some instances - dispensed portion.
Dimensions & Capacities
Fast Flow ............................................................................................................... 1 ½ to 3 oz./sec.
UFB-1 ......................................................................................................................... 2 to 4 oz./sec.
Ultra Flow .............................................................................................................. 3 to 4 ½ oz./sec.
Operational temperature range: ......................................................... 10°C (50°F) to 43°C (110° F)
Voltage requirements:................................................................................ 22 to 27 VAC (50/60 Hz)
Transformer (electronic valves) ........................................................................................80 VA min.
Operating Pressure (flowing)...............................................................................syrup = 20 psi min.
.............................................................................................................................water = 35 psi min.
Concentrates and juices that contain particulates must be dispensed from a juice valve.
A slanted drip tray is necessary when using an Optifill valve.
SYSTEM DETAILS
Water
Water Quality
Water quality issues have an affect on dispensing valves. Chloramine, a combination of chlorine and
ammonia is responsible for some degradation of rubber components. Chloramine is used in many U. S.
water supplies. Its affects can be minimized by installing and maintaining a water filtration system.
Ultra pure water affects the sensitivity of the Optifill™ valve. Because ultra pure water has less mineral
content, it reduces the conductivity of the water keeping the circuit open and overfilling the beverage
container.
Water Flow
The size of the orifice in the piston varies depending on whether the piston is used for syrup or water, and
whether it is high flow or ultra flow valve.
Concentrate valve sleeve
has only one hole Syrup valve sleeve
has six holes
Mounting
screw
Water
lever
FIGURE 16
IntelliCarb Training Manual
Publication Number: TP01071 - 12 - © 2004, IMI Cornelius Inc.
NOTE: The notched water piston on the Ultra Flow and UFB-1 valve.
results in at least one orifice in the sleeve always open. This elimi-
nates pulsating and smooths water flow at higher flow rates.
In operation the liquid flows through the knifeedged orifice in the bottom
of the piston and then out the orifices in the sleeve. The outlet orifice size
in the sleeve is regulated by the position of the piston. In the illustration,
the piston is restricting approximately 1/2 of the outlet orifices.
FIGURE 18
FIGURE 19
The position of the piston inside the sleeve is determined by the upward pressure of the liquid against the
base of the piston and the downward pressure of the spring inside the piston (not shown here). The
pressure of the spring is regulated by the adjusting screw.
If the pressure of the liquid increases, the flow rate through the knifeedged orifice will increase. The
piston is moved upward closing off more of the outlet orifices. The same flow rate is thereby maintained.
Notch in
piston
FIGURE 17
Orifice
Sleeve
Piston
UFB-1 Flow Module
Lower Fluid Pressure BUT
Larger Orifice Openings
Syrup/Water Flow
Knife
edge
Same Volume Of
Syrup/Water Flows
From Orifices
Higher Fluid Pressure BUT
Smaller Orifice Openings
Lower Fluid
Pressure Push-
ing Against Pis-
ton & Spring
Higher Fluid
Pressure Pushing
Against Piston &
Spring
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 13 - Publication Number: TP01071
Adjusting Flow Rates
Flow rates of the water and syrup are adjusted based on the desired ratio. For example: if the desired
ratio is 5:1, then the flow rate of the water is 5 times that of the syrup.
If the desired finished drink total flow rate is 3.0 ounces per second, then the water flow rate is 2.5 oz./
sec and the syrup flow rate is 0.5 oz./sec. (The water at 2.5 oz./sec is five times the 0.5 oz./sec syrup flow
rate.)
NOTE: Always adjust water within its range.
Calculating Flow Rates
The most frequent ratio is 5:1. The charts above list the breakdown for many ratios and flow rates. It is
useful to be able to calculate flow rates when a chart is not available.
An example of calculating the water and syrup flow rates given the finished drink flow rate and the water
to syrup ratio:
Given:
1. Finished Drink Flow Rate = 3.0 oz./sec.
2. Water to Syrup Ratio = 5 to 1
To calculate Water Flow Rate:
1. Calculate the Total Portions = Water Portion + Syrup Portion
(example 5 + 1 = 6)
2. Calculate Syrup Flow Rate = Finished Drink Flow Rate ÷ Total Portions
(example 3.0 oz./sec ÷ 6 = .5 oz./sec)
3. Calculate Water Flow Rate = Finished Drink Flow Rate Syrup Flow Rate
(example 3.0 oz./sec - .5 oz./sec = 2.5 oz./sec)
Prove the calculation is correct by adding water flow rate of 2.5 oz./sec + syrup flow rate of .5 oz./sec =
finished drink flow rate of 3.0 oz./sec.
Water flowing at 2.5 oz./sec and syrup flowing at .5 oz./sec achieves a ratio of 5:1 and 3.0 oz./sec. flow
rate.
Syrup/Concentrate
Syrup should always be precooled before setting the ratio. Syrup takes a path through the valve
parallel to the water path. It is introduced in the block, travels through a syrup flow control, banjo, valve
head and out the nozzle. Note, concentrate is not cooled.
High sugar syrups are more viscous (thicker) than diet syrups and consequently have more
pressure drop within a system. This pressure drop results in less flow at the valve and therefore a slower
fill time. Increasing the pump pressure will help overcome the pressure drop caused by high sugar
syrups.
Water Flow Rates At Selected Ratios
Water To Syrup
Ratio
Water at 1.5 oz./
sec. Total Flow
Water at 3.0 oz./
sec. Total Flow
Water at 3.75 oz./
sec. Total Flow
Water at 4.5 oz./
sec. Total Flow
2 to 1 1.00 oz./sec. 2.00 oz./sec. 2.50 oz./sec. 3.00 oz./sec.
3 to 1 1.13 oz./sec. 2.25 oz./sec. 2.81 oz./sec. 3.38 oz./sec.
4 to 1 1.20 oz./sec. 2.40 oz./sec. 3.00 oz./sec. 3.60 oz./sec.
5 to 1 1.25 oz./sec. 2.50 oz./sec. 3.13 oz./sec. 3.75 oz./sec.
6 to 1 1.29 oz./sec. 2.57 oz./sec. 3.21 oz./sec. 3.86 oz./sec.
7 to 1 1.31 oz./sec. 2.63 oz./sec. 3.28 oz./sec. 3.94 oz./sec.
IntelliCarb Training Manual
Publication Number: TP01071 - 14 - © 2004, IMI Cornelius Inc.
Setting Ratios
If the ratio varies and must be adjusted often, it is probably the result of a restricted syrup
system. It is then time to clean and sanitize the syrup tubing and cooling coils and check for other
problems such as syrup pumps, etc.
NOTE: Try raising the pressure on the pump before cleaning.
Set the water flow rate first, then adjust the syrup to the desired ratio. This gives the most accurate
valve flow setting possible. Measure the ratio and adjust the syrup flow, if necessary. This will result in
uniform flow, better carbonation retention, and improved drink quality.
When using a ratio cup always take these precautions to ensure accuracy:
After installing the separator tube, open the valve to fill the syrup tube before starting the ratio test.
Clean the cup thoroughly between tests so there is no carryover from one test to the next.
Fill the cup to approximately 3/4 full and use approximately the same quantity for each test to ensure
accurate settings.
Take another sample to verify the settings.
FIGURE 20
NOTE: Valve troubleshooting information is available on page 39.
Ratio Cup and Syrup Separator
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 15 - Publication Number: TP01071
SHURFLO
SHURFLOW OVERVIEW
SHURflos Beverage Gas Pump supplies syrup under pressure to a post-mix dispenser, which mixes the
syrup with water to an exact ratio (brix). The pump is used in conjunction with non-pressurized Bag-In-
Box (B-I-B) containers and a bag connector (Q.D.) fitting.
The pump can be operated on regulated CO2, nitrogen or compressed filtered air. The compressed gas
drives the pump and is not in contact with the syrup. Separate syrup and gas chambers prevent
contamination, foaming, and purging of the tubing when the B-I-B has emptied.
The pump retains pressure in the outlet line, operating only when syrup is needed. When the dispenser
valve is opened, the pump reacts to the pressure drop by operating to maintain pressure in the line.
When the dispenser is closed, the incoming gas and output syrup pressures equalize and the pump
stops. Actual dynamic line pressure is dependant upon system losses as outlined in the section
"Pumping Capability".
The automatic "sold-out" feature within the pump ensures consistent syrup delivery right up to the
moment the B-I-B is empty. Vacuum produced by the pump evacuates the syrup within the bag. Once the
preset vacuum point is achieved and held, incoming gas pressure to the pump is shutoff causing the
outlet syrup pressure to drop to zero. When a new B-I-B is installed, the vacuum drops, the pump
automatically restarts and pressurizes the system. The SHURflo Beverage Gas Pump ensures quality
from the first drink to the last.
Beverage Gas Pumps are intended for soda syrups and low viscosity concentrates that do not contain
solids.
The use of a SHURflo Juice Pump (-09) is recommended for concentrates containing soft solids, classed
as round, up to 0.025 in. [0.6 mm] or that are of higher viscosity than soda syrups.
When concentrates contain pulp classed as long/stringy, seed particles or are exceptionally viscous, the
Particulate Juice Pump (-10) should be used as it can handle soft solids up to 1 /4" [6 mm] cubed.
Standard gas pump models are for installations where geographic elevation is less than 5000 ft.[1523M].
For elevations above 5000 ft. specific high altitude models with a reduced sold-out spring rate must be
used to compensate for the loss in atmosheric pressure.
For further application and model information please contact SHURflo.
NOTE: Shurflow Troubleshooting information available on page 35.
IntelliCarb Training Manual
Publication Number: TP01071 - 16 - © 2004, IMI Cornelius Inc.
SHURFLOW INSTALLATION
As indicated on the pump, the outlet port is to be mounted up.
Pumps are to be mounted at the same level or higher than the B-I-B. The best choice is to have the
pump above the B-I-B.
INLET tubing from the B-I-B to the pump use; 3/8" I.D. [10mm] minimum, heavy wall (1/8"
[3mm]) clear, NSF listed vacuum tubing. Inlet tubing should not have excessive length. Tub-
ing that is allowed to drape down can trap air in the B-I-B creating a potential for pump "sold-
out" problems. The maximum vertical distance from the bottom of the B-I-B to the pump must
not exceed 5 ft [1.5 M ]. Maximum inlet tubing length is 10 ft. [3 M ].
If plumbing multiple B-I-Bs to a pump, B-I-B's should be "Teed" side-by-side horizontally,
rather than one on top of the other (vertically).
OUTLET tubing from the pump to the dispenser should be high pressure rated and NSF
listed. Consult "Pumping Capability" (see page 2) for appropiate tubing I.D.
Always cut CO2 and outlet tubing at least 2 ft. [.6 M] longer to provide a "service loop" so the
B-I-B rack can be moved for cleaning or service.
Use new (clean), 1/4" I.D. [6 mm], flexible, high pressure, braided tubing from the CO2 / air
regulator to the pump.
NEVER connect a transfer tank "system" in series with a B-I-B system. Syrup contaminants in
old components may work their way through the air supply causing premature failure of the gas
pump. Gas used to operate pumps MUST be clean and contain no contaminants (syrup, oil, rust,
water, etc). Air compressors may be used with proper particle filters and moisture separators. Air storage
tanks should be drained regularly. Pumps subjected to contaminated air are not covered by warranty.
High concentrations of CO2 can be fatal as it will displace the air from non-ventilated areas.
Pumps operated by CO2 must be in ventilated areas.
If placed in a confined area (basement, closet, cooler box, etc.), exhaust fans capable of changing
the room air on a continuous basis should be used.
All tubing connections must be secured with stainless steel, stepless Oetiker ® clamps.
Cable-tie all tubing securely to prevent kinks or sags that inhibit performance or cause damage to the
pump fittings.
START-UP PROCEDURE
1. Confirm that all tubing connections are properly clamped, fittings are tight, and tubing is not kinked.
Install bag connector to the B-I-B.
2. Adjust gas regulator to about 20 psi. [1.4 bar] allowing the pump to stroke slowly.
3. Operate the valve until all air trapped within the tubing has been purged.
4. Once the air has been purged, adjust the CO2 regulator to the pressure necessary to main-
tain the desired brix. The most efficient gas usage occurs at 40 psi. [2.8 bar]. MAXIMUM
static gas pressure to the pump is 85 psi. [5.8 bar], minimum 20 psi. [1.4 bar].
Flowrates that result in a stroke-rate of more than two strokes per second will decrease pump
life. (Consult factory) Pump failure due to "overrunning" is not covered by the limited warranty.
To prevent air from entering the system always leave the bag connector attached to the empty
B-I-B until a new B-I-B can be installed. Air entered into the system, via air in the bags or
vacuum leaks, may cause brix fluctuation, foaming, spitting, non-operation of the vacuum sold-
out or pump "run-on" with the valve closed. Symptoms of this kind can lead to a misdiagnosis of the
pump.
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 17 - Publication Number: TP01071
PLUMBING
TYPICAL INSTALLATION
FIGURE 21. Typical Installation
IntelliCarb Training Manual
Publication Number: TP01071 - 18 - © 2004, IMI Cornelius Inc.
PLUMBING LAYOUT
FIGURE 22. Plumbing Layout
Regulator
55-60 psi
CO2 Supply
BCB
A
C
D
E
E
Water Filter
BIB Syrup
BIB Pump
BIB Pump
6-10 Brand
Flavors
3-5 Per Side
Carb Water In
3/8" Female Fir Nut
3/8" Barb Conn
1/4" Barb Conn
3/8" Hose Barb - 3/4" NP
1/4" Female Flr Nut
Direct Conn to SUR
Outlet on BIB Pmp
Direct Conn to CO2
Inlet on BIB Pmp
Syr Inlet BIB Pmp
3/4" NPT TEE
D
C
B
E
H
A
F
G
Tubing Legend
Connection Legend
3/8" Bev Tubing
1/4" Bev Tubing
3/8" Tycon Tubing
BIB Syrup
Plain Water In
Brand Syrup Inlets
Brand Syrup Inlets
3-5 Per Side
G
G
H
H
F
F
Carb
Pump
I
Regulator
100 psi
Carbonator Tank CO2 Inlet
I D
A
BB
75 psi Fixed Reg
E
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 19 - Publication Number: TP01071
FLOW DIAGRAM 1XX (SIX FLAVOR MODEL)
FIGURE 23. Flow Diagram 1xx (Six Flavor Model)
INSTALL FOR
NON--CARB AS
REQUIRED
NON--CARB
WATER
PLUGGED
S1
CHECK
VA LVE
OPTIONAL FOR
DIET DRINKS
OR ROOT BEER
S5
SYRUP TANKS
15--50 PSIG
PRESSURE
REGULATORS
CARB ONATOR
TANK
COLD PLATE
CARBONATOR
PUMP
FILTER
OPTIONAL
PRESSURE
REGULATOR
CO2
CYLINDER
S7
FA UC ET S
POTABLE
WATER
SUPPLY
S1
S3
COLDPLATE
INLET
CONNECTIONS
S5
S2
S3 S2
4
5
FAUCETS VIEWED FROM THIS SIDE
1
ITEMS INSIDE BROKEN LINE
INCLUDED WITH UNIT
5--15
PSIG
DOUBLE CHECK
VA LVE
6
75 PSI
S5
3
2
S6S7
S6
S4
S3
S2
S1
W1
S6
W2
W2
W1
W1,
VALVES 1,2,
3,6
W2,
VALVES 4,5
IntelliCarb Training Manual
Publication Number: TP01071 - 20 - © 2004, IMI Cornelius Inc.
FLOW DIAGRAM 1XX (EIGHT FLAVOR MODELS)
FIGURE 24. Flow Diagram 1XX (Eight Flavor Models)
INSTALL FOR
NON--CARB AS
REQUIRED
NON--CARB
WATER
S8
CHECK
VA LVE
OPTIONAL FOR
DIET DRINKS
OR ROOT BEER
S4 S5
SYRUP TANKS
15--50 PSIG
S3
PRESSURE
REGULATORS
CARBONATOR
TANK
5
COLD PLATE
CARBONATOR
PUMP
FILTER
OPTIONAL
PRESSURE
REGULATOR
CO2
CYLINDER
S8
S7
FAUCETS
POTABLE
WATER
SUPPLY
S1
S3
S4
COLDPLATE
INLET
CONNECTIONS
S5
S2
S2 S1
6
7
FAUCETS VIEWED FROM THIS SIDE
1
ITEMS INSIDE BROKEN LINE
INCLUDED WITH UNIT
5--15
PSIG
DOUBLE CHECK
VA LVE
8
75 PSI
S7
3
4
2S6S7
S8
S6
S5
S4
S3
S2
S1
W1
S6
W2
W2
W1
W1,
VALVES 1,2,
3,7,8
W2,
VALVES 4,
5,6
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 21 - Publication Number: TP01071
FLOW DIAGRAM 2XX (EIGHT FLAVOR MODELS)
FIGURE 25. Flow Diagram 2xx (Eight Flavor Models)
INSTALL FOR
NON–CARB AS
REQUIRED
S6
CHECK
VALVE
OPTIONAL FOR
DIET DRINKS
OR ROOT BEER
S1
SYRUP TANKS
15–50 PSIG
S2 S3
PRESSURE
REGULATORS
6
S1
COLD PLATE
CARBONATOR
FILTER
OPTIONAL
PRESSURE
REGULATOR
CO2
Cylinder
FAUCETS
POTABLE
WATER
SUPPLY
W2
W1
COLDPLATE
INLET
CONNECTIONS
S4 S5
7
8
ITEMS INSIDE BROKEN LINE
INCLUDED WITH UNIT
5–15
PSIG
5
2
3
4
1S8S7
S4
S3
S2
S5
S6
S7
S8
Non–Carb Water
W1
VALVES 1,2
3,6,7,8
W2
VALVES 4,5
W1
W2
CARBONATOR
TANK
W1
W2
DOUBLE CHECK
VALVE
75 PSI
IntelliCarb Training Manual
Publication Number: TP01071 - 22 - © 2004, IMI Cornelius Inc.
FLOW DIAGRAM 2XX (TEN FLAVOR MODELS))
FIGURE 26. Flow Diagram 2xx (Ten Flavor Models)
S8S1 S2
S9
S10
CHECK
VALVE
PRESSURE
REGULATORS
S3 S4 S5
8
S1
5
COLD PLATE
CARBONATOR
PUMP
FILTER
OPTIONAL
PRESSURE
REGULATOR
CO2
CYLINDER
FAUCETS
POTABLE
WATER
SUPPLY
6
S6 S7
9
10
INSTALL FOR
NON–CARB AS
REQUIRED
FAUCETS VIEWED FROM THIS SIDE
ITEMS INSIDE BROKEN LINE
INCLUDED WITH UNIT
OPTIONAL FOR
DIET DRINKS
OR ROOT BEER
5–15
PSIG
7
COLDPLATE
INLET
CONNECTIONS
2
3
4
1
SYRUP TANKS
15–50 PSIG
S10S9
S4
S3
S2
S5
S6
S7
S8
W1
VALVES 1,2,3
4,7,8,9,10
W2
VALVES 5,6
NON CARB WATER
S9
S10
S1
S4
S3
S2
S5
S6
S7
S8
W2
W1
W2
W1
CARBONATOR
TANK
DOUBLE CHECK
VALVE
75 PSI
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 23 - Publication Number: TP01071
FLOW DIAGRAM 300 (TWELVE FLAVOR MODELS)
FIGURE 27. Flow Diagram 300 (Twelve Flavor Models)
S8S3 S2
CHECK
VALVE
PRESSURE
REGULATORS
S1 S6 S5
10
CARBONATOR
PUMP
FILTER
OPTIONAL
PRESSURE
REGULATOR
CO2
CYLINDER
FAUCETS
POTABLE
WATER
SUPPLY
S4 S9
11
12
INSTALL FOR
NON–CARB AS
REQUIRED
FAUCETS VIEWED FROM THIS SIDE
OPTIONAL FOR
DIET DRINKS
OR ROOT BEER
5–15
PSIG
TO COLDPLATE
SYRUP INLETS
SYRUP TANKS
15–50 PSIG
S12S7
NON–CARB WATER
S11
S12
S10
W2
W1
DOUBLE CHECK
VALVE
S10S11
CO2
W1
W2
S10
S11
S12
S7
S8
S9
COLD PLATE
COLDPLATE
INLET
CONNECTIONS
7
8
9
S8
S9
S7
W1
W2
4
FAUCETS
5
6
S5
S6
S4
W2
W1
W1
W2
S4
S5
S6
S1
S2
S3
COLD PLATE
COLDPLATE
INLET
CONNECTIONS
1
2
3
S2
S3
S1
W1
W2
ITEM INSIDE BROKEN LINE
INCLUDED WITH UNIT
CARBONATOR TANK
75 PSI
IntelliCarb Training Manual
Publication Number: TP01071 - 24 - © 2004, IMI Cornelius Inc.
ELECTRICAL SECTION
FIGURE 28. Electrical Box 1xx Single Transformer
FIGURE 29. Electrical Box 2xx Single Transformer
FIGURE 30. Electrical Box 2XX Dual Transformer
Control Box Single Transformer Will Power
up to Three Valves Simultaneously. Transformer
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 25 - Publication Number: TP01071
CARBONATOR WIRING DIAGRAM
RESET CONNECTIONS
Time Out Selection Pins.
7min/3 min/Disabled
(Move Jumper to Select)
IntelliCarb Training Manual
Publication Number: TP01071 - 26 - © 2004, IMI Cornelius Inc.
WIRING DIAGRAM 1XX (120V)
FIGURE 31. Wiring Diagram 1xx (120V)
B
L
A
C
K
B
L
A
C
K
KEY SWITCH
B
L
A
C
K
O
R
A
N
G
E
R
E
D
B
L
A
C
K
R
E
D
W
H
I
T
E
BLACK WHITE
B
L
U
E
G
R
E
E
N
BLUE
RED
PINK
BLACK
BLACK
WHITE
BLACK
BLACK BLACK
PINK
B
L
A
C
K
W
H
I
T
E
TO BEVERAGE FAUCET
BLACK
BLACK
Q.C.
CONNECTOR
B
L
A
C
K
W
H
I
T
E
R
E
D
G
R
E
E
N
WHITE
WHITE
RED
WHITE
BLACK
BLACK
WHITE
B
L
U
E
B
L
U
E
BLUE RED
R
E
D
B
L
A
C
K
W
H
I
T
E
YELLOW
GRD
115V
SUPPLY
YELLOW
OPTIONAL
-- +
OPTIONAL
WHITE
OPTIONAL
WHITE
BLACK
G
R
E
E
N
TO HINGE
GRN
L
N
NC NOCOM
L1
L2
COMNO
NC
T’STAT LIGHT
WHT
ICE LEVEL
OPTION
12
DANGER! ELECTRIC SHOCK HAZARD. DISCONNECT
POWER BEFORE SERVICING UNIT.
SERVICE INFORMATION
DISPENSE
SWITCH
MOTOR
HEATER
CCW
AGITATOR
MOTOR
GATE
SOLENOID
(106VDC)
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 27 - Publication Number: TP01071
SCHEMATIC 1XX
FIGURE 32. Schematic 1xx
T’STAT
LIGHT
CAPACITOR
AGITATOR MOTOR
GATE
SOLENOID
BEVERAGE TRANSFORMER
MOTOR HEATER
OPTIONAL LIGHT
OPTIONAL
STARTER
OPTIONAL
BALLAST
TIMER
L1
L2
OPTIONAL LOW ICE LEVEL
BEVERAGE
VALVES
BEVERAGE
VALVES
N.O.
L
RECTIFIER
N.C.
C
VEND SWITCH
GN
BEVERAGE PA NEL
IntelliCarb Training Manual
Publication Number: TP01071 - 28 - © 2004, IMI Cornelius Inc.
WIRING DIAGRAM 2XX (120V MODEL)
FIGURE 33. Wiring Diagram 2xx (120V Model)
Q.C. CONNECTOR
R
E
D
B
L
A
C
K
R
E
D
B
L
A
C
K
BLACK
W
H
I
T
E
BLACK
W
H
I
T
E
B
L
A
C
K
Y
E
L
L
O
W
WHITE
WHITE
WHITE
BLACK
RED
G
R
E
E
N
BLACK
WHITE
R
E
D
W
H
I
T
E
B
L
A
C
K
B
L
A
C
K
Y
E
L
L
O
W
W
H
I
T
E
B
L
A
C
K
W
H
I
T
E
1
B
L
U
E
BLACK
GATE
SOLENOID
(106VDC)
DANGER!
SERVICE INFORMATION
ELECTRIC SHOCK HAZARD. DISCONNECT
POWER BEFORE SERVICING UNIT.
WHITE
BLACK
BLACK
DISPENSE
SWITCH
BLACK
WHITE
W
H
I
T
E
G
R
E
E
N
G
R
E
E
N
TO HINGE
BLK
BLACK
R
E
D
KEY SWITCH
TO BEVERAGE VALVES
MOTOR
HEATER
AGITATOR
MOTOR
B
L
A
C
K
B
L
A
C
K
YELLOW
4
NC NO COM
N
L2
2
3
G
R
E
E
N
B
L
U
E
TO 24V
TRANSFORMER
-- +
B
L
U
E
Y
E
L
B
L
K
OPTIONAL
LIGHT SOCKET
OPTI ONAL
LIGHT BALLAST
BLACK
WHITE
L
GRN
R
E
D
W
H
I
T
E
WHITE
BLACK
B
L
U
E
B
L
A
C
K
B
L
U
E
B
L
U
E
WHITE
I CE LEVEL SI GNAL
OPTI ON
BLUE
2
LIGHTT’STAT
RECTIFIER
MOTOR START
CAPACITOR
OPTIONAL
LIGHT
STARTER
MOTOR
START
RELAY
AGITATION
TIMER
BEVERAGE
TRANSFORMER
(OPTI ONAL)
BLUE
BEVERAGE
TRANSFORMER
(OPTI ONAL)
NC L1
NOCOM
OPTIONAL
LIGHT SOCKET
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 29 - Publication Number: TP01071
WIRING DIAGRAM 2XX (220/240V MODELS)
FIGURE 34. Wiring Diagram 2xx (220/240V Models)
BROWN
L
POWER LINE
FILTER
KEY SWITCH
TO BEVERAGE VALVES
MOTOR
HEATER
AGITATOR
MOTOR
B
L
A
C
K
B
L
A
C
K
YELLOW
4NO
NC L1
NC
NOCOM
N
L2
2
3
WHITE
TO 24V
TRANSFORMER
N
B
L
K
BLACK WHITE
L
R
E
D
WHITE
BLACK
B
L
U
E
B
L
A
C
K
B
L
U
E
ICE LEVEL SIGNAL
OPTION
BLUE
2
BROWN
B
L
A
C
K
BROWN
LT B L U E
GRN/YEL
E
G
R
N
/
Y
E
L
G
R
N
/
Y
E
L
TO
BEVERAGE
PANEL
DISPENSE
SWITCH
BLACK
BLACK
ELECTRIC SHOCK HAZARD. DISCONNECT
POWER BEFORE SERVICING UNIT .
SER VICE INFORMATION
DANGER!
GATE
SOLENOID
1
Y
E
L
L
O
W
B
L
A
C
K
W
H
I
T
ECOM
WHITE
BLACK
LIGHT
L
O
A
D
LT BLUE
GRN
TO HINGE
GUSSET
BLK
LT BLUE
LT BLUE
T’STAT
RED
BLACK
WHITE
WHITE
WHITE
B
L
A
C
K
W
H
I
T
E
BLACK
W
H
I
T
E
B
L
A
C
K
R
E
D
B
L
A
C
K
G
R
N
/
Y
E
L
B
L
U
E
Q.C. CONNECTOR
MOTOR START
CAPACITOR
OPTIONAL
LIGHT
STARTER
MOTOR
START
RELAY
AGITATION
TIMER
BEVERAGE
TRANSFORMER
(OPTIONAL)
OPTIONAL
LIGHT
SOCKET
G
R
N
/
Y
E
L
BLUE
W
H
I
T
E
BLACK
LINE
LAMP
BROWN
OPTIONAL
LIGHT
SOCKET
OPTIONAL
LIGHT
BALLAST
POWER
SWITCH
BROWN
BROWN
G
R
N
/
Y
E
L
G
R
N
/
Y
E
L
G
R
N
/
Y
E
L
G
R
N
/
Y
E
L
G
R
N
/
Y
E
L
BLACK
N
FIL TER
ASY
L
G
R
N
/
Y
E
L
L
T
B
L
U
E
B
R
O
W
N
BROWN
BROWN
R
E
D
R
E
D
B
L
U
E
J10
J9
BEVERAGE
TRANSFORMER
(OPTIONAL)
IntelliCarb Training Manual
Publication Number: TP01071 - 30 - © 2004, IMI Cornelius Inc.
WIRING DIAGRAM 2XX (220/240V MODELS)
FIGURE 35. Wiring Diagram 2xx (220/240V Models)
AGITATOR MOTOR
GATE
SOLENOID
OPTIONAL
BEVERAGE TRANSFORMER
MOTOR HEATER
OPTIONAL LIGHT
OPTIONAL
STARTER
OPTIONAL
BALLAST
TIMER L2
L1
OPTIONAL ICE LEVEL
OPTIONAL
BEVERAGE
VALVES
OPTIONAL
BEVERAGE
VALVES
N.O.
L
RECTIFIER
N.C.
C
VEND SWITCH
GN
BEVERAGE PANEL
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 31 - Publication Number: TP01071
WIRING DIAGRAM 300 (220/240V MODELS)
FIGURE 36. Wiring Diagram 300 (220/240V Models)
YELLOW
YELLOW YELLOW
YELLOW
W
H
I
T
E
W
H
I
T
E
W
H
I
T
E
W
H
I
T
E
B
L
A
C
K
R
E
D
B
L
A
C
K
B
L
A
C
K
OPTIONAL
LIGHT
SOCKET
KEY
SWITCH
(OPTIONAL)
TO HINGE BRACKET
TO BEVERAGE
FAUCET
PINK
GATE
SOLENOID
(DC COIL)
DISPENSE
SWITCH
RIGHT
AGITATOR
MOTOR
(CW)
DISPENSE
SWITCH
2
1
ICE LEVEL
SIGNAL OPTION
BLUE
LIGHTT’STAT
NC NO COM
L2
L1
COMNO
NC
OPTIONAL
LIGHT
BALLAST
WHITE
YELLOW
B
L
A
C
K
BLUE
B
L
U
E
B
L
U
E
WHITE
BLACK
BLACK
WHITE
WHITE
BEVERAGE
TRANSFORMER
(OPTIONAL)
R
E
D
W
H
I
T
E
B
L
A
C
K
AGITATION
TIMER
BLACK
BLACK
OPTIONAL
LIGHT STARTER
PINK
BLACK
BLACK
WHITE
BLACK
BLACK
RED
BLACK
B
L
A
C
K
W
H
I
T
E
R
E
D
B
L
U
E
R
E
D
O
R
N
B
L
A
C
K
MOTOR
CAPACITOR
TO 24V TRANSFORMER
KEY
SWITCH
(OPTIONAL)
B
L
A
C
K
B
L
A
C
K
GATE
SOLENOID
(DC COIL)
LEFT
AGITATOR
MOTOR
(CCW)
2
1
ICE LEVEL
SIGNAL OPTION
BLUE
LIGHTT’STAT
N
L
GRN
G
R
E
E
N
WHITE
OPTIONAL
LIGHT
BALLAST
B
L
U
E
W
H
I
T
E
R
E
D
B
L
A
C
K
O
R
N
MOTOR
CAPACITOR
TO 24V TRANSFORMER
GRN
B
L
A
C
K
R
E
D
BLUE
B
L
U
E
B
L
U
E
WHITE
BLACK
G
R
N
/
Y
E
L
WHITE
WHITE
TO BEVERAGE
FAUCET
BEVERAGE
TRANSFORMER
(OPTIONAL)
G
R
E
E
N
W
H
I
T
E
B
L
A
C
K
BLACK
BLACK
OPTIONAL
LIGHT STARTER
MOTOR
HEATER
W
H
I
T
E
B
L
A
C
K
BLACK
WHITE
BLACK
BLACK
RED
BLUE
G
R
E
E
N
GREEN/YELLOW
YELLOW
WHITE
RED
B
L
U
E
B
L
U
E
RED
MOTOR
HEATER
OPTIONAL
LIGHT
SOCKET
OPTIONAL
LIGHT
SOCKET
J10
J9
BLUE
BLUE
BLUE
BLUE
DANGER!
SERVICE INFORMATION
ELECTRIC SHOCK HAZARD. DISCONNECT
POWER BEFORE SERVICING UNIT.
IntelliCarb Training Manual
Publication Number: TP01071 - 32 - © 2004, IMI Cornelius Inc.
WIRING DIAGRAM 300 (220/240V MODELS)
FIGURE 37. Wiring Diagram 300 (220/240V Models)
DANGER ELECTRIC SHOCK HAZARD. DISCONNECT
POWER BEFORE SERVICING UNIT.
SERVICE INFORMATION
RED
BLACK
BLACK
WHITE
BLACK
B
R
N
B
L
U
B
R
N
MOTOR
HEATER
OPTIONAL
LIGHT STARTER
BLACK
B
L
A
C
K
G
R
E
E
N
BEVERAGE
TRANSFORMER
(OPTIONAL)
TO BEVERAGE
FAUCET
BLUE
WHITE
WHITE
B
L
U
E
B
L
U
E
BLUE
RED
R
E
D
B
L
A
C
K
GRN
TO 24V TRANSFORMER
MOTOR
CAPACITOR
O
R
N
B
L
A
C
K
R
E
D
W
H
I
T
E
B
L
U
E
OPTIONAL
LIGHT
BALLAST
WHITE
G
R
E
E
N
GRN
L
N
T’STAT LIGHT
BLUE
ICE LEVEL
SIGNAL OPTION
12
LEFT
AGITATOR
MOTOR
(CCW)
GATE
SOLENOID
(DC COIL)
B
L
A
C
K
B
L
A
C
K
KEY
SWITCH
(OPTIONAL)
TO 24V TRANSFORMER
MOTOR
CAPACITOR
B
L
A
C
K
O
R
N
B
L
U
E
R
E
D
W
H
I
T
E
B
L
A
C
K
BLACK
RED
BLACK
BLACK
WHITE
BLACK
BLACK
PINK
OPTIONAL
LIGHT STARTER
AGITATION
TIMER
W
H
I
T
E
BEVERAGE
TRANSFORMER
(OPTIONAL)
WHITE
WHITE
BLACK
BLACK
B
L
U
E
B
L
U
E
BLUE
RED
B
L
A
C
K
YELLOW
WHITE
OPTIONAL
LIGHT
BALLAST
NC NO COM
L1
L2
COMNO
NC
T’STAT LIGHT
BLUE
ICE LEVEL
SIGNAL OPTION
12DISPENSE
SWITCH
RIGHT
AGITATOR
MOTOR
(CW)
DISPENSE
SWITCH
GATE
SOLENOID
(DC COIL)
PINK
TO BEVERAGE
FAUCET
TO HINGE
KEY
SWITCH
(OPTIONAL)
OPTIONAL
LIGHT
SOCKET
B
L
A
C
K
B
L
A
C
K
B
L
A
C
K
W
H
I
T
E
W
H
I
T
E
W
H
I
T
E
W
H
I
T
E
YELLOW
YELLOW
YELLOW
YELLOW
BLUE
G
R
E
E
NB
R
N
YELLOW
BRN
WHITE
BRN
B
L
U
E
B
L
U
E
RED
R
E
D
MOTOR
HEATER
OPTIONAL
LIGHT
SOCKET
ON/OFF
SWITCH
OPTIONAL
LIGHT
SOCKET
J10
J9
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 33 - Publication Number: TP01071
SCHEMATIC 300 (120V MODELS)
FIGURE 38. Schematic 300 (120V Models)
CAPACITOR
BEVERAGE PANEL
OPTIONAL
BEVERAGE TRANSFORMER
OPTIONAL ICE LEVEL
OPTIONAL
BEVERAGE
VALVES
MOTOR HEATER
OPTIONAL LIGHT
GATE
SOLENOID
N.O.2
N.C.2
C
VEND SWITCH
AGITATOR MOTOR
CAPACITOR
BALLAST
STARTER
AGITATOR MOTOR
GATE
SOLENOID
OPTIONAL
BEVERAGE TRANSFORMER
MOTOR HEATER
OPTIONAL LIGHT
STARTER
BALLAST
OPTIONAL ICE LEVEL
OPTIONAL
BEVERAGE
VALVES
N.O.1
L
N.C.1
C
VEND SWITCH
GN
BEVERAGE PANEL
TIMER L2
L1
RECTIFIER
IntelliCarb Training Manual
Publication Number: TP01071 - 34 - © 2004, IMI Cornelius Inc.
SCHEMATIC 300 (220/240V MODELS)
FIGURE 39. Schematic 300 (220/240V Models)
OPTIONAL BEV. TRANSFORMER
LINE
FILTER
AGITATOR MOTOR
GATE
SOLENOID
OPTIONAL
BEV. TRANSFORMER
MOTOR HEATER
OPTIONAL LIGHT
OPTIONAL STARTER
OPTIONAL
BALLAST
N.C1
L
N.O1
C
VEND SWITCH
GN
MOTOR HEATER
E–BOX GD.
POWER
PUSH BUTTON
SWITCH
EMC
BEVERAGE
KEYLOCK SWITCH
BEV. FAUCETS
EMC
GATE
SOLENOID
VEND SWITCH
N.O2
N.C2
C
AGITATOR MOTOR
OPTIONAL BALLAST
OPTIONAL STARTER
OPTIONAL LIGHT
BEV. FAUCETS
24V
24V
TIMER L2
L1
RECTIFIER
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 35 - Publication Number: TP01071
TROUBLESHOOTING
SHURFLOW TROUBLESHOOTING
Pumping Capability
For example:
The distance syrup can be delivered is
limited by inherent factors (restrictions) within
the inlet & outlet sides of the beverage
dispensing system. Due to variances in
system configuration and equipment, an
accurate determination of pressure drop is
difficult. Before deciding on a systems
tubing size, SHURflo recommends
estimating system losses by considering the
following:
Syrup viscosity and temperature (coldplate,
re-circ., etc.).
Total syrup flow rate of valve(s) connected
to a pump.
Inside diameter of the inlet/outlet tubing,
fittings, bag connector, etc.
Horizontal & vertical distance of the outlet
tubing.
Vertical tubing runs will reduce total achievable
tubing run length. To estimate the losses within
the vertical distance, use the chart to the
right. Take 1% of the distance in feet [3% if
meters]. The resulting number is multiplied by
the vertical distance. This product is then
subtracted from the maximum horizontal
distance. The resulting length is the total
horizontal/vertical (horz./vert.) tubing run that is
obtainable for that flow rate, tubing I.D. and
viscosity.
Distances shown are the results of tests conducted at 70°F
[21°C] ambient with a static pressure of 85 psi. [5.8 bar] to the
pump. All distances assume a dynamic pressure of 35 psi. [2.38
bar] at the dispenser to maintain brix.
FLO W RATE
/
SEC .
1/
4" I.D.
[6 m m ]
3/
8" I.D.
[10mm]
1/
2" I.D.
[13mm]
OZ.mL Feet Meter Feet Meter Feet Meter
Diet
Soda
Syrup
(5 cP s.±3)
.5 15 500+ 152+ 500+ 152+ 500+ 152+
.7 5 22.5500 152 500+ 152+ 500+ 152+
1.0 30 453 138 500+ 152+ 500+ 152+
1.5 45 212 65 500+ 152+ 500+ 152+
2.0 60 102 31 500 152 500+ 152+
2.5 75 64 19 398 121 500 152
3.0 90 32 9297 90 500 152
3.5 105 -- -- 212 65 500 152
Standard
Soda
Syrup
(20 cP s.±3)
.5 15 500 152 500 152 500+ 152+
.7 5 22.5133 40 500 152 500+ 152+
1.0 30 79 24 388 118 500 152
1.5 45 32 9193 59 500 152
2.0 60 10 3127 39 366 112
Heavy
Soda
Syrup
(35 cP s.±3)
.5 15 129 39 500 152 500+ 152+
.7 5 22.575 23 345 105 500+ 152+
1.0 30 53 16 239 73 500 152
1.5 45 26 8127 39 425 129
MAXIMUM HORIZONTAL TUBING
LENGTHS
BY
VISCOSITY
Distances shown are intended as a guidline only.
(cPs.=Centipose)
TOTAL TUBING RUN
370 ft. [113M]
3/8" I.D. [10mm]
TUBING
HEAVY SODA
SYRUP
GAS IN 22 ft. [6.7M]
VERTICAL
FAST FLOW VALVE
1/2 oz./sec. [15 mL]
(syrup flow only)
3/8" I.D. [10mm]
TUBING (min.)
IntelliCarb Training Manual
Publication Number: TP01071 - 36 - © 2004, IMI Cornelius Inc.
The chart indicates that heavy syrup with 1/2 oz./sec [15mL] flow-rate (per the illustration) can be
sustained over a horizontal distance of 500 ft. [152M] when 3/8" I.D. [10mm] tubing is used.
Feet: Take 1% of 500 ft. (500 x 1%) = 5. Which then is multiplied by the 22 ft. vertical, (22 x 5) =
110 ft.
Subtract this product from the 500 ft. (500 - 110) =390. The results indicate a 390 ft. tubing run
(horz./vert.) is possible, while the example only requires a distance of 370 ft.
Meters: Take 3% of 152M (152 x 3%) = 4.56. Which then is multiplied by the 6.7M vertical, (4.56 x
6.7) = 30.5M.
Subtract this product from the 152M (152-30.5)=121.5. The results indicate a 121.5M tubing run
(horz./vert.) is possible, while the example only requires a distance of 113M.
NOTE: Had the example above resulted in a value that was equal to, or less than the nec-
essary total tubing run, consider a larger I.D. tubing or installation of a pump(s) in series
using a SHURflo Vacuum Regulator.
Pumps in Series for Long Distances
Long tubing runs or high vertical lift can be achieved by installing pumps in series. Standard
SHURflo Beverage pumps are not designed to have positive pressure on the inlet side. The
SHURflo Vacuum Regulating Valve (VRV) allows the pump to receive liquid from a pressurized
source. By positioning a VRV at the inlet of the secondary pump, incoming pressure is reduced
to zero, permitting syrup to be drawn in under vacuum.
SHURflo can recommend several other methods to meet the requirements for a particular installation,
including Pressurized Inlet Pumps or Accumulators. Contact SHURflo for more information.
Pump Sanitizing / Winterizing
Sanitization of the SHURflo Beverage Gas Pump is required. The frequency of Sanitization is
dependant on the concentrate type and its manufacturers requirements. Factors which also
affect the frequency of this procedure are: temperature, concentrate volatility, facility conditions,
installation and equipment. The sanitizing procedure fulfills a required 10 minute contact time
with a 200 ppm Sodium Hypochlorite solution. Refer to SHURflo Service Bulletin #1025 for the
N.S.F. listed sanitizing procedure for the SHURflo pump (only). Pumps that are subjected to
freezing (below 32° F [0°C]) must be purged of fluid to prevent damage. Refer to SHURflo
Service Bulletin #1025 for complete winterizing procedure. Refer to the equipment
manufacturers instructions for sanitizing and winterizing procedure for carbonators, dispensers
and tubing.
Pumps that have been winterized and/or out of service for a period of time should be sanitized prior to
being placed back in service.
Never apply pressure to the pumps liquid inlet. Pressurized tanks may damage internal
components if used to sanitize or purge fluid from the pump (operating or not).
GAS IN
B-I-B
SECOND
PUMP
VRV
FIRST
PUMP
TO NEXT
VRV/PUMP
OR
DISPENSER
GAS TO NEXT
PUMP
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 37 - Publication Number: TP01071
Pump Troubleshooting
DOES NOT OPERATE / GAS APPLIED / DISPENSER VALVE OPEN
B-I-B empty or inlet tubing pinched off activating vacuum "sold-out".
Gas regulator over-pressurizing. (Pump stalled)
Outlet tube kinked or restricted.
Operated without fluid for excessive period. (Dry run)
Transfer tube and gas lines contaminated (syrup, rust, oil, etc.) [ensure clean gas supply, change
out all contaminated pumps]
Internal damage of control cover.
OPERATES BUT WILL NOT PRIME / DISPENSER VALVE OPEN
[consult Start-up Procedure for proper priming]
Pump valves have no moisture/dry (add water/syrup to the inlet port with pump stroking slowly).
Vacuum leaks at Q.D., barb fitting clamps, or inlet fitting o-ring.
Debris in valve seats or warped/swollen valves.
DOES NOT ACHIEVE SOLD-OUT WITH EMPTY B-I-B
Vacuum leaks at Q.D., barb fitting clamps, or inlet fitting o-ring.
Excessive amount of air in B-I-B from improper packaging.
Air trapped in outlet tubing and/or pump fluid chambers.
AIR IN INLET AND/OR OUTLET TUBING
Vacuum leaks at Q.D. o-ring or barb fitting clamps.
Vacuum leaks at inlet fitting; o-ring pinched or missing.
Large amounts of air noticed only in the outlet tubing when pump operates (diaphragm/piston assem-
blies ruptured).
STROKES WITH DISPENSER VALVE CLOSED
Air trapped in outlet tubing and/or pump fluid chambers (open outlet and purge air, check for vacuum
leaks, or air in B-I-B).
Debris in outlet valves or warped/swollen valves.
FLUID FROM EXHAUST OR VISIBLE WITHIN GAS INLET TUBING
Carbonator check valve.
Ensure clean gas supply.
Diaphragm/piston assemblies ruptured.
[change out all contaminated pumps]
GAS BLOWING FROM EXHAUST CONTINUOUSLY
Control cover subjected to contaminated gas supply or damaged (ensure clean gas supply, change
out all contaminated pumps).
IntelliCarb Training Manual
Publication Number: TP01071 - 38 - © 2004, IMI Cornelius Inc.
DISPENSER TROUBLESHOOTING
Should your unit fail to operate properly, check that there is power to the unit and that the hopper
contains ice. If the unit does not dispense, check the following chart under the appropriate symptoms to
aid in locating the defect.
Trouble Probable Cause Remedy
BLOWN FUSE OR CIRCUIT
BREAKER. A. Short circuit in wiring
B. Inoperable gate solenoid.
C. Inoperable agitator motor.
A. Repair wiring.
B. Replace gate solenoid.
C. Replace agitator motor.
GATE DOES NOT OPEN.
AGITATOR DOES NOT
TURN.
A. No power.
B. Bent depressor plate (does not
actuate switch).
C. Inoperable dispensing switch.
A. Restore power.
B. Replace depressor plate.
C. Replace dispensing switch.
GATE DOES NOT OPEN OR
IS SLUGGISH. AGITATOR
TURNS.
A. Inoperable gate solenoid.
B. Excessive pressure against gate
slide.
C. Inoperable rectifier.
A. Replace gate solenoid.
B. Adjust gate slide.
C. Replace rectifier.
ICE DISPENSES CONTINU-
OUSLY. A. Stuck or bent depressor plate
(does not release switch).
B. Inoperable dispensing switch.
C. Improper switch installation.
A. Replace depressor plate.
B. Replace dispensing switch.
C. Make sure switch is installed
properly.
SLUSHY ICE. WATER IN
HOPPER. A. Blocked drain.
B. Unit not sitting level.
C. Poor ice quality due to water qual-
ity or icemaker problems.
D. Improper use of flaked ice.
A. Unplug drain.
B. Level the unit.
C. Correct water quality or repair ice-
maker.
D. Call Service Person.
BEVERAGES DO NOT DIS-
PENSE A. No 24 volts power to faucets.
B. No CO 2 pressure.
A. Restore 24 volt power to faucets.
B. Restore CO 2 pressure.
BEVERAGES TOO SWEET A. Carbonator not operating. A. Repair carbonator.
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 39 - Publication Number: TP01071
VALVE TROUBLESHOOTING
Excess Foam
Check
product
temperature
Check
system
Remove
nozzle
below 40°
Excess Foam
Check flow
rates
Clean
Problem
corrected
Check
system
Set flow rate
and ratio
Problem
corrected
Correct
? yes
no
Clean
?
Temp
?above 40°
yes
no
Problem:
excess foam
IntelliCarb Training Manual
Publication Number: TP01071 - 40 - © 2004, IMI Cornelius Inc.
Off Taste
Remove
nozzle
Clean
no
Off Taste
Problem
corrected
Clean
?Check ratio
Correct
?
Check
system
Set ratio
yes
yes
no
Problem
corrected
Problem:
off taste
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 41 - Publication Number: TP01071
Valve Stuck Open
Check
solenoid
visually
Check for
damaged
banjos
Valve Stuck Open
Check for
power at
solenoid
working
?yes (solenoid up)
Problem: valve
stuck open
Undetermined
problem call
800-238-3600
Damage
?
Replace
banjos
no
yes
Problem
corrected
Clean or
replace
solenoid
Problem
corrected
no (solenoid down)
Power
?
Replace
dispensing
switch
Problem
corrected
yes
no
IntelliCarb Training Manual
Publication Number: TP01071 - 42 - © 2004, IMI Cornelius Inc.
No Product
Check
solenoid
visually
Check
system
Check
voltage
(22-27 AC)
no
No Product
Check
switch
Problem
corrected
Power
?
Working
? yes
no
Problem:
no product
Check
resistance
of coil
40 ohms
?
Check
system
Replace
solenoid
Problem
corrected
yes
yes
no
Check
transformer
no
Replace
switch no
yes
IntelliCarb Training Manual
© 2004, IMI Cornelius Inc. - 43 - Publication Number: TP01071
CARBONATOR TROUBLESHOOTING
WARNING: Disconnect electrical power to the unit to prevent personal injury before attempting any
internal maintenance. Only qualified personnel should service the internal components or the elec-
trical wiring.
If repairs to the carbonated water or the plain water systems must be made, disconnect electrical
power to the Unit, then shut off CO2 and plain water sources. Dispense from dispensing valve until
carbonator tank CO2 pressure has been relieved.
Solid State Carbonator Level Control
FIGURE 40
NOTE: Carbonators that are equipped with a pump safety thermostat will have a black wire
instead of green connected to the C terminal.
Test Solid State Level Control
1. Remove all wires and:
Carb. motor should run.
2. Jumper C to HI:
Carb. motor should stop. Do not remove jumper wire.
3. Jumper LO to C:
Motor should remain stopped.
4. Remove 1st jumper from C and HI:
Motor should remain stopped.
5. Remove 2nd jumper from C and LO:
Motor should start.
If level control passes all above test, replace probe.
Trouble Probable Cause Remedy
CARBONATOR WILL NOT
OPERATE. A. Power cord unplugged or circuit
breaker open in panel box.
Inoperative carbonator.
B. Inoperative carbonator.
A. Plug in power cord or reset circuit
breaker.
B. Call a qualified Service Person.
WATER PUMP MOTOR
WILL NOT SHUT OFF. A. Carbonator internal problem. A. Call a qualified Service Person.
ERRATIC CYCLING OF
CARBONATOR.
A. Carbonator internal problem. A. Call a qualified Service Person.
WATER PUMP MOTOR
OPERATES BUT WATER
PUMP DOES NOT PUMP
WATER.
A. Carbonator internal problems or a
water supply line problem. A. Call a qualified Service Person.
CARBONATOR CARBON-
ATED WATER CAPACITY
TOO LOW
A. Carbonator internal problems or a
water supply line problem.
B. Water filter clogged.
A. Call a qualified Service Person.
B. Replace water filter.
C
HI
LO
MATING
CONNECTION
WIRING HARNESS
GREEN
ORANGE
RED GROUND
TERMINAL
CARBONATED LIQUID
LEVEL CONTROL
PROBE ASSY
SHORT ELECTRODE
LONG ELECTRODE
CARBONATOR TANK
C
HI ORANGE
LO RED
2ND JUMP
1ST JUMP
FIGURE 41
IMI Cornelius Inc.
www.cornelius.com
800-238-3600