Corning Optical Communication Wireless QXC85P19A17 QX REMOTE UNIT User Manual
Corning Optical Communication Wireless QX REMOTE UNIT
User Manual
Corning MobileAccess MobileAccessQX User Manual P/N: 709C0011101 REV: A00 Date: JANUARY2013 Preface Material RF Safety To comply with FCC RF exposure compliance requirement, adhere to the following warnings: Warning! Antennas used for this product must be fixed mounted on indoor permanent structures, providing a separation distance of at least 75 cm from all persons during normal operation. Warning! Each individual antenna used for this transmitter must be installed to provide a minimum separation distance of 75 cm or more from all persons and must not be co-located with any other antenna for meeting RF exposure requirements. Warning! Antenna gain should not exceed 12.5 dBi. Warning! The design of the antenna installation needs to be implemented in such a way so as to ensure RF radiation safety levels and non-environmental pollution during operation. ATTENTION Compliance with RF safety requirements: • MobileAccess products have no inherent significant RF radiation • The RF level on the downlink is very low at the downlink ports. Therefore, there is no dangerous RF radiation when the antenna is not connected. CAUTION Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Preface Material P/N: 709C0011101 Page II Laser Safety Care of Fiber Optic Connectors Fiber optic ports of the MobileAccessQX system emit invisible laser radiation at the 1310/1550 nm wavelength window. Do not remove the protective covers on the fiber optic connectors until a connection is ready to be made. Do not leave connectors uncovered when not connected. The laser apertures /outputs are the green SC/APC Bulkhead adapters located on the front panel of the equipment. The tip of the fiber optic connector should not come into contact with any object or dust. External optical power is less than 10 mW, Internal optical power is less than 500 mW. Refer to the cleaning procedure for information on the cleaning of the fiber tip. To avoid eye injury never look directly into the optical ports, patchcords or optical cables. Do not stare into beam or view directly with optical instruments. Always assume that optical outputs are on. Only technicians familiar with fiber optic safety practices and procedures should perform optical fiber connections and disconnections of MobileAccessQX devices and the associated cables. MobileAccessQX has been tested and certified as a Class 1 Laser product to IEC/EN 60825-1 (2007). It also meets the requirements for a Hazard Level 1 laser product to IEC/EN 60825-2: 2004 to the same degree. MobileAccessQX complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice NO. 50 (2007). MobileAccessQX employs a Class 3B laser and therefore the following label is affixed inside the unit adjacent to the laser: Preface Material P/N: 709C0011101 Page III Standards and Certification Corning MobileAccess products have met the approvals of the following certifying organizations: Company Certification ISO ISO 9001: 2000 and ISO 13485: 2003 Product Certifications US Radio Equipment and Systems: • FCC 47 CFR Part 22 – for CELL Frequency Band • FCC 47 CFR Part 24 – for PCS Frequency Band • FCC 47 CFR Part 27 – for 700 LTE and AWS Frequency Bands EMC • FCC 47 CFR Part 15 Subpart B Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. Warning! Changes or modifications to this equipment not expressly approved by Corning MobileAccess could void the user’s authority to operate the equipment. Europe Radio Equipment and Systems EN 301 502 – for GSM / EGSM Frequency Bands Standards and Certification P/N: 709C0011101 Page IV EN 300 328 – for WLAN 802.11b/g 2.4GHz Frequency Band EN 301 893 – for WLAN 802.11a 5GHz Frequency Band EMC EN 301 489 Safety EN 60950UL 60950 CAN/CSA-C22.2 No.60950 UL 2043 Laser Safety CDRH 21 CFR 1040.10, 1040.11 (Except for deviations per notice No.50, July 26, 2001) IEC 60825-1, Amendment 2 (January 2001) EN 60825-1 About this Guide and Other Relevant Documentation This user guide describes how to perform the physical installation of the MA2000 systems. The installation procedures of other units (e.g. RIU, SC-450) relevant to the system are detailed in their user manuals (see Additional Relevant Documentation below). Additional Relevant Documents The following documents are required if the corresponding units are included in your system. Document Name RIU Installation and Configuration Guide System Controller (SC-450) User Manual MobileAccessQX Datasheet MA Software Version Update Tool About this Guide and Other Relevant Documentation P/N: 709C0011101 Page V List of Acronyms BDA Bi-Directional Amplifier BTS Base Transceiver Station BTSC Base Transceiver Station Conditioner BU Base Unit DL Downlink RU Remote (Hub )Unit RIU Radio Interface Unit RBS Radio Base Station UL Uplink List of Acronyms P/N: 709C0011101 Page VI Table of Contents Preface Material ........................................................................................................................II RF Safety .......................................................................................................................................... II Laser Safety ..................................................................................................................................... III Care of Fiber Optic Connectors .......................................................................................................... III Standards and Certification ................................................................................................... IV Company Certification ....................................................................................................................... IV Product Certifications ........................................................................................................................ IV About this Guide and Other Relevant Documentation .......................................................... V List of Acronyms ..................................................................................................................... VI Table of Contents................................................................................................................... VII Introduction ........................................................................................................................1 1.1 Key Features and Capabilities ....................................................................................................... 1 1.2 System Architecture ..................................................................................................................... 2 1.3 QX Interfaces and Internal Modules .............................................................................................. 4 1.3.1 QX Interfaces ..................................................................................................................... 4 1.3.2 QX Main Internal Modules ................................................................................................... 6 1.4 SCU-F Interfaces .......................................................................................................................... 7 Installation Guidelines .......................................................................................................8 2.1 Infrastructure Preparation ............................................................................................................ 8 2.2 Installation Requirements ............................................................................................................. 8 2.3 Coaxial Cable Connections ............................................................................................................ 8 2.3.1 General Cable Installation Procedures .................................................................................. 8 2.3.2 RF Rules ............................................................................................................................ 9 2.3.3 Coax Cable Lengths and Losses ........................................................................................... 9 2.4 Fiber Optic Rules ....................................................................................................................... 10 2.5 Power Consumption, Connections and Power Supplies ................................................................. 11 2.5.1 Power Safety Instructions ................................................................................................. 11 2.5.2 Types of Power Supplies ................................................................................................... 11 2.6 Installation Conventions ............................................................................................................. 11 System Installation ..........................................................................................................12 3.1 Overview of Physical Installation ................................................................................................. 12 3.2 Unpacking and Inspection .......................................................................................................... 12 Table of Contents I P/N: 709C0011101 I Page VII 3.3 Inserting an RHU/AO Module in to QX Chassis ............................................................................. 14 3.4 Mounting ................................................................................................................................... 16 3.4.1 Rack Mount Installations ................................................................................................... 16 3.4.1.1 Plan the rack installation ....................................................................................... 16 3.4.1.2 Rack Installation Safety Instructions ...................................................................... 17 3.4.1.3 Mounting QX Unit in 19-IN Rack ............................................................................ 17 3.4.1.4 Mounting SCU-F Unit ............................................................................................ 17 3.4.2 Wall Mount Installation ..................................................................................................... 18 3.4.2.1 QX Horizontal Wall Mount Installation .................................................................... 19 3.4.2.2 QX Vertical Wall Mount Installation ........................................................................ 21 3.5 Connections............................................................................................................................... 24 3.5.1 QX Fiber Optic Connections ............................................................................................... 24 3.5.1.1 MIMO Configurations ............................................................................................ 25 3.5.2 RF Connections ................................................................................................................ 26 3.5.2.1 QX RF and Antenna Monitoring Connections .......................................................... 26 3.5.2.2 RF MIMO Connections to SCU-F ............................................................................ 28 3.5.2.3 Daisy Chaining the AMU modules of Multiple QX Units to a Single SCU-F ................. 29 3.5.2.4 SCU-F to Broadband Antenna Connections ............................................................. 30 3.5.3 Grounding the QX Unit ...................................................................................................... 30 3.5.4 Power Connections ........................................................................................................... 31 3.6 Verifying Normal Operation ........................................................................................................ 32 Maintenance .....................................................................................................................34 4.1 Replacing an RHU/AO Module ..................................................................................................... 34 4.2 Replacing Fan Module ................................................................................................................ 36 Appendix A: System Specifications ...............................................................................38 RF Parameters .................................................................................................................................. 38 Supported Services .................................................................................................................... 38 RF Parameters per Service at Antenna Port of Four Port Service Combiner Unit (SCU-F) ................. 39 Absolute Maximum Rating .......................................................................................................... 40 Optical Specifications ........................................................................................................................ 40 Environmental Specifications.............................................................................................................. 40 Standards and Approvals ................................................................................................................... 41 System Component Specifications ...................................................................................................... 42 Quad-Service Package (QX) ........................................................................................................ 42 Four - Port Service Combiner Unit (SCU-F) .................................................................................. 42 Appendix B: Ordering Information..................................................................................43 Table of Contents I P/N: 709C0011101I Page VIII 1 Introduction MobileAccess2000 QX (QX) is a member of the MobileAccess2000 family. It is a compact, modular, cellular indoor coverage remote unit supporting up to four services (currently, CELL/PCS, LTE and AWS). 1.1 Key Features and Capabilities All services are received from the head-end, over a single optic fiber and reconverted to RF for convergence and distribution over a common DAS antenna infrastructure. • Multi-Service Platform - Supports up to four services. Currently supported: CELL, PCS, AWS, 700 MHz LTE • Multi-Operator Optimized Platform Services from a number of operators can be supported by the same chassis or by different units and distributed over common DAS antenna infrastructure. • Optic Fiber savings - All services routed to a QX unit are routed over a single optic fiber • Modular Design upgrades – simply QX (and the conditioning module • Scalable MIMO Upgrades - Upgrade any or all services from SISO to MIMO by cascading another QX unit • Small Footprint - 3 U height rack • Simple maintenance - All connections and monitoring LEDs located on front panel, Modular, hot-swap, field replaceable service modules, including fan modules • Web Management - Web management via the SC-450 controller Service support can be quickly added as needed by inserting card like modules into the chassis without any downtime or additional cabling. In addition, two QX units can be cascaded to provide various combinations of SISO and MIMO services distributed over the same antenna infrastructure. MA2000 QX is managed by opening a Web session to the SC-450 Controller. MA2000 QX operates along with an SCU-F unit, which converges the services from one or more MA2000 QX units and provides the interface to the DAS infrastructure. Both QX and SCU-F are described in this manual. MobileAccessQX Figure 1-1 Introduction I P/N: 709C0011101I Page 1 The following benefits are achieved with the QX platform: Seamless service add a card in the parallel service at the head end) 1.2 System Architecture The QX and SCU-F are located at the floor level remote end. QX receives RF over optic service signals from the head end, reconverts the signals to RF over copper, adjusts them to the required level and outputs each service to dedicated interfaces. The signals are combined by the SCU-F (along with services from other QX units) and distributed over a common DAS (Distributed Antenna System) infrastructure. In the uplink, cellular service signals received at the DAS are separated by the SCU-F and routed to their dedicated QX ports. The signals are then converted to optic and forwarded to the head-end for reconversion to RF and distribution to the relevant BTS or BDA systems. Note: 3rd party equipment is sold separately (i.e. cabling, antennas). QX Architecture Diagram Figure 1-2 Headend: At the headend CMA elements provide interface to the wireless service provider’s network, condition the signals and convert them to optical signals for transportation over fiber optics towards the remote ends. • Radio Interface Unit (RIU) - the RIU conditions and custom tunes the RF Downlink (DL) signals from an operator’s signal source (BTS or BDA) to ensure a constant RF level. In the Uplink (UL), the signal (at the required level) is routed back to the operator’s signal source. System Architecture I P/N 709C011101 I Page 2 • RF to Optic converter unit – this can either be a Base Unit (BU) or an Optical Control Head End Unit (OCH), where the OCH is QX model specific. These are wideband units that convert the RF Downlink (DL) signals from the RIU into optical signals for routing over single or multi-mode fiber optic cabling (SMF/MMF) to/from the QX units located at the remote locations up to 2Km away. • System Controller (SC-450) - the system controller enables centralized remote management and control of MobileAccess elements. This unit connects directly to the RIU and BU and/or OCH and allows management of these as well as their hosted elements (e.g. QX) via a controller Web session. Remote End: At the remote end, the optical signal is reconverted to RF, filtered, amplified to the appropriate level, combined with other signals and distributed over the broadband antenna infrastructure. The QX unit is installed, along with the Four Port Service Combiner Unit (SCU-F). The QX system remote end consists of the following elements: • QX - each QX unit provides coverage for four RF services (e.g. CELL, PCS, 700LTE and AWS) via two types of service dedicated internal modules (RHU and AO). Each of these modules is monitored via the Controller as an independent unit. • Service Combiner Unit (SCU-F): a passive module that combines and distributes the UL and DL signals from one or more QX units to (up to) four broadband antennas. QX Solution System Architecture Figure 1-3 System Architecture I P/N 709C011101 I Page 3 1.3 QX Interfaces and Internal Modules 1.3.1 QX Interfaces This section provides a full, detailed description of the QX unit and relevant interface connections (Table 1-2) and LED indicators. Fan modules AMU connection ports Optic port slot DC power AC power AMU service ports MobileAccessQX Front Panel Figure 1-4 Table 1-1. QX Front Panel Interfaces Interface Description DB-15 AMU (Antenna Monitoring Unit) port. Connect to parallel port on SCU-F. Note that only one QX unit port can be connected to the parallel SCU-F port. For installations with more than one QX, cascade QX AMU ports using IN/OUT ports. IN/OUT AMU cascading ports. Use in case there are more than one QX units connected to the SCU-F. DB-9 RS232 serial connection (D-Type 9); Serves as AMU console port for service personnel Console Connect to network for AMU SW upgrade – for tech support personnel only Service specific QMA connectors Used for connecting to corresponding SCU-F High band and Low Band QMA connectors. Optic Port Slot Slot used to guide the optic fiber to the RHU module fiber optic SC/APC port inside the chassis. AC In Local AC power connection: 100-240VAC (use either AC or DC) DC In Remote DC power connection: 25 to 48VDC (use either AC or DC) QX Interfaces and Internal Modules I P/N 709C011101 I Page 4 The QX front panel supports three groups of LEDs: system level, for the RHU and for each Addon unit. MobileAccessQX Front Panel Figure 1-5 Table 1-2: LEDs Descriptions: Module LED Description QX (system level) Power Steady Green: Required power is supplied to AMU module of QX chassis Off: No power supplied to AMU module of QX chassis Steady Green: AMU module SW initialized Blinking Green: AMU module SW is initializing (blinks for the duration of approx. 1 minute) Steady Green: Fan status normal Blinking Green: Faulty fan, alarm triggered Steady Green: Power input detected for RHU module Off: No power detected for RHU module Blinking Green: Active communication detected – connected and discovered by the BU/OCH Steady Slow Blink: Faulty communication link - no external communication is received Steady Green: Normal optical link level from BU/OCH-QX Blinking Green: Low optical link level from BU/OCH-QX Off: No optical link is present Steady Green: Power input detected for first/second AddOn unit Off: No power detected for first/second Add-On unit Blinking Green: Indicates that the Add-On module is in normal operating mode. Run Fan RHU Power Comm Link AO1/AO2 Power Run Table 1-3: LED Descriptions QX Interfaces and Internal Modules I P/N 709C011101 I Page 5 1.3.2 QX Main Internal Modules The QX main components consist of the following internal modules: • Remote Hub Unit (RHU) – service specific unit, supports two voice services, converts the optical signals received from the BU/OCH to RF signals (and vice versa) and routes them to the coax antenna infrastructure (via the Four Port Service Combiner Unit – SCU-F). • Add-On (AO) – adds an additional voice service to the host RHU (QX includes two AO modules hosted by the RHU) Note: The voice services are combined by the connected Service Combiner Unit (SCU). • Antenna Monitoring Unit (AMU) – digital unit that enables antenna monitoring and relay messaging of the following information: • Antenna status • Fans status • Fans control • AMU/QX alarms. The AMU is connected to the SCU. The AMU modules of a number of QX units can be daisy chained to a single SCU-F (see section 3.5.2.1). • Fan Module – two extractable fans, simple to maintain and replace (see section 4.2). QX Interfaces and Internal Modules I P/N 709C011101 I Page 6 1.4 SCU-F Interfaces The SCU-F is a passive unit which interfaces to the QX RF service ports and internal AMU module and to the DAS infrastructure. All of the interfaces are located on the front panel (shown in Figure 1-6). DB-15 port to QX DB-15 port Antenna Ports 1-4 SCU-F Front Panel Low Band (1-4) ports; High Band (5-8) ports Figure 1-6 Table 1-4. SCU-F Front Panel Interfaces Interface Description DB-15 DB-15 port used to connect the SCU-F to the QX DB-15 port (internal AMU module port) Antenna Ports N-Type RF antenna ports used to connect to the broadband antenna infrastructure QMA Ports (Low/High) QMA type RF ports used to connect to the QX service ports: Low: Ports 1-4 support low band service connections from the QX High: Ports 5-8 support high band service connections from the QX SCU-F Interfaces I P/N 709C011101 I Page 7 2 Installation Guidelines 2.1 Infrastructure Preparation This following installation rules are based on the assumption that site survey and installation planning (including power requirements) have been completed. 2.2 Installation Requirements The infrastructure preparation consists of two main phases: Floor Planning: Planning the distribution of the antennas on each floor to provide the required coverage. Telecom Closet Planning: Planning the layout of the devices and cables in the telecom closet or shaft. 2.3 Coaxial Cable Connections 2.3.1 General Cable Installation Procedures Observe the general cable installation procedures that meet with the building codes in your area. The building code requires that all cabling be installed above ceiling level (where applicable). The length of cable from the risers to each antenna must be concealed above the ceiling. The cable must be properly supported and maintained straight using tie-wraps, cable trays and clamps or hangers every 10 feet (where practical above ceiling level). Where this is not practical, the following should be observed: • The minimum bending radius of 7” is required for the supplied ½” coax cable. • Cable that is kinked or has a bending radius smaller than 7” must be replaced. • Cable runs that span less than two floors should be secured to suitably located mechanical structures. • The cables should be supported only from the building structure. Installation Guidelines I P/N: 709C0011101I Page 8 x 2.3.2 RF Rules • When using the MobileAccess system in an environment in which other indoor coverage systems are installed, it is recommended (where possible) that the antennas are placed at least two meters apart • When bending coax cables, verify that the bending radius does not exceed the coax specifications. • Use wideband antennas supporting a range of 800Mhz to 2500Mhz • Use a VSWR meter (i.e. Site Master or equivalent) for checking coax cables, including the antennas. (<2). The VSWR must be measured prior to terminating the RUs in the remote communication rooms • Terminate all unused SCU ports with a 50 ohm load 2.3.3 Coax Cable Lengths and Losses Use coax ½”, 50ohm, male-to-male QMA type, for connecting to SCU broadband antenna ports. NOTE: The required distance between the antennas (installed in the ceiling) depends on the infrastructure and calculated path-loss. For example, if there is free space-loss between the antennas, a minimum distance of 100 ft is required; if there are partitions (loss) between the antennas, a distance of less than 100 ft between them is allowed. Coax Length coax Loss (900Mhz) connector loss Total Loss 30 0.7 1.5 2.2 40 0.9 1.5 2.4 50 1.1 1.5 2.6 60 1.3 1.5 2.8 70 1.5 1.5 80 1.7 1.5 3.2 90 1.9 1.5 3.4 100 2.1 1.5 3.6 110 2.3 1.5 3.8 120 2.5 1.5 130 2.7 1.5 4.2 140 2.9 1.5 4.4 150 3.1 1.5 4.6 160 3.3 1.5 4.8 170 3.5 1.5 180 3.7 1.5 5.2 190 3.9 1.5 5.4 200 4.1 1.5 5.6 Coaxial Cable Connections I P/N 709C011101 I Page 9 2.4 Fiber Optic Rules • Either single mode or multimode fiber can be used with QX products. • Only Multimode fiber, 50/125 or 62.5/125um complying with ANSI/TIA/EIA-568-B series, EN50173-1 or ISO/IEC 11801 can be used. The fiber length can be up to 300 meters assuming the following qualifications: • All fiber in a given length of fiber must be of the same core diameter. • All Bulkhead adapters must be Single mode SC/APC (Green) adapters. • All terminations cross connections or patches must be direct fusion splice or MobileAccess specified patch cords listed below. 900 microns pathcord for splicing, 2 Meters, 2xSC/APC Diamond p/n 62.5/125/900 ENC/1045341 Diamond p/n ENC/1045340 Beige boots, Black boots, 50/125/900 MA# 500001057 MA# 500001058 Zipcord patchcord, 4xSC/APC, 50/125/900/2000/4500 micron Diamond p/n ENC/1045342 Meter Black/Brown boots, 1 MA# 50000105 Diamond p/n ENC/1045343 Meter Black/Brown boots, 3 MA# 500001060 Zipcord patchcord, 4xSC/APC, 62.5/125/900/2000/4500 micron Diamond p/n ENC/1045344 Meter Beige/Brown boots, 1 MA# 500001061 Diamond p/n ENC/1045345 Meter Beige/Brown boots, 3 MA# 500001062 • Use only 8-degree SC APC connectors (green color). • Use only fusion splice for connecting two fibers. • Use minimum splicing/connectors to achieve minimum losses on the fibers (<0.5dB). • Use precaution while installing, bending, or connecting fiber optic cables. • Use an optical power meter and OTDR for checking the fiber optic cables. • Make sure the environment is clean while connecting/splicing fiber optic cables. • All fiber optic connections should be cleaned prior to attaching to termination points using a dry cleaning device (i.e. Cletop or equivalent). • Fiber connector protective caps should be installed on all non-terminated fibers and removed just before they are terminated. • Verify the Fiber Optic connections. • Pay special attention while connecting the SC APC connectors - you must hear the “click” when the connection is made. Fiber Optic Rules I P/N 709C011101 I Page 10 2.5 Power Consumption, Connections and Power Supplies 2.5.1 Power Safety Instructions SAFETY WARNINGS When installing or selecting the power supplies: • It is required to install a circuit breaker of 7.5A for the DC supply circuit. • Be sure to disconnect all power sources before servicing. • Calculate the required power according to the requirements of the specific installation and then determine the configuration of the power supplies. The required DC cables will then be determined by the selected PS configuration. • Use only UL approved power supplies • AC and DC power supply cables – only use the power cords supplied with the units 2.5.2 Types of Power Supplies CMA supplies various power supplies that can be installed in a rack or mounted on a wall, depending on your configuration. 2.6 Installation Conventions Some of the basic installation conventions are listed below for the QX system: • QX - usually placed in the communication shaft or closet of a corresponding floor so they can be easily located. Each QX unit can typically cover a floor of up to 30,000 sq ft. • Fiber optic cable - bundled fibers are terminated into the Base Units/Optical Control Hubs in the main communication room. The fibers are then routed to each coverage locations where individual fibers terminate into splice boxes. The splice box couples the installed fiber into the remote units. Enough spare fibers should be installed to take into account future expansion of the system. • For remote power supply configuration - cable bundles are routed from the main communication room and individual wire pairs are terminated into the power feed of individual units. By providing power from a single distribution point, maintenance can be reduced and UPS backup can be easily provided. The maximum distance from the source to the termination spot is 1000 feet using 18 gauge wires. In many locations local codes do not require power to be run through conduit if 100 watts or less is used. Please consult the regulations in your local jurisdiction prior to deploying remote power. When power cables require distances greater than 1000 feet 14 or 16 gauge wire may be used. • On each floor - the antennas are connected to the Service Combiner Unit (SCU) using coax cables. Power Consumption, Connections and Power Supplies I P/N 709C011101 I Page 11 3 System Installation The following sections provide an overview of the installation procedure for the QX and an SCU-F unit. Note: The QX must be installed with the SCU (in rack installations - preferably below the SCU). The QX can be mounted using one of the following options: • 19-in Rack – pre-assembled rack ears • Wall mount (interfaces facing front like in a rack installation) – supplied bracket • Vertical wall mount –interfaces facing down - ordered separately (P/N AK-QX-ENC-WMT-V) NOTE: Be sure to read the Installation Requirements (see section 2.2) and Power Consumption related instructions (see 2.3.3section 2.5) before proceeding with the actual connections. 3.1 Overview of Physical Installation Physical installation procedure steps 1. Unpacking and inspecting supplied items for QX and SCU-F units – see section 3.2. 2. Mounting SCU-F unit (not included – ordered separately) 3. Mounting QX unit 3.2 Unpacking and Inspection This section provides instructions for opening the shipping box, verifying that all supplied items have been received, and verifying that no shipping damage has occurred. Unpack and inspect the cartons according to the following procedure 1. Open the shipping carton and carefully unpack each unit from the protective packing material. 2. Check for signs of external damage. If there is any damage, call your CMA service representative. System Installation I P/N: 709C0011101I Page 12 3. Verify that all supplied items have been received for the QX (see Table 3-1) and Table 3-2). Table 3-1: Package Contents Kit Item P/N Description QTY. QX QX chassis Empty chassis AC Power Cable 705900007 Black, Straight, USA Length=1.8-2.5m , 110V DC Power Cable 705A030821 DC, Power Cable Edges. Length=5m Flat Cable 705900003 QMA Cable ,UL, Open RJ45 to RJ45 communication cable. Length 2m-2.15m 705A042101 QMA to QMA straight cable, R/A,0.141", Length=430mm Flat Cable (preconnected) 705A042601 RJ45 to RJ45 communication cable. Length=700mm AWS Add-On QMA Cable 705A042101 QMA to QMA straight cable, R/A,0.141", Length=430mm LTE Add-On QMA Cable 705A042101 QMA to QMA straight cable, R/A,0.141", Length=430mm RHU Module – (service specific) 10A with Table 3-2: SCU-F Package Contents Kit Item P/N Description SCU-F SCU-F SCU-F Four Port Service Combiner Unit with DB-15 to DB-15 Digital Cable 705A042301 Used for connecting the SCU-F DB-15 port to the QX DB-15 port (internal AMU module interface) QTY. Unpacking and Inspection I P/N 709C011101 I Page 13 3.3 Inserting an RHU/AO Module in to QX Chassis The QX chassis and Remote Hub Unit (RHU) and Add-On (AO) modules are provided separately, whereas the modules must be inserted in to the chassis. This requires opening the QX chassis front panel door and inserting the modules into their respective slots. The RHU/AO modules are hot swappable and can be inserted either before or after the system installation. To insert an RHU/AO Module 1. Open the QX door, by unscrewing the two captive screws. QX Front Door Screws Figure 3-1 2. Referring to the slot allocation labels inside of the chassis door, position the service module in the relevant slot with the handle facing front. Refer to Figure 3-2. IMPORTANT! Dummy modules must be inserted in unoccupied slots for termination. Slot Allocations for Service Modules Figure 3-2 NOTE 1: Termination modules are required for unoccupied slots – ordered separately. NOTE 2: When installing an LTE AO unit, an indication of the use of an internal or external filter must be selected – via the GUI. 3. Slide the module towards the back of the unit and fit the module ejectors in to the side notches of the slot (verify that the screws are unscrewed). Refer to Figure 3-3. Inserting an RHU/AO Module in to QX Chassis I P/N 709C011101 I Page 14 Positioning New Module in Designated Slot Figure 3-3 4. Push the module all the way back until it “clicks” in to the chassis backplane. 5. Close ejectors and close both captive screws to secure the module in place. Refer to Figure 3-4. 6. For each Add-On module, connect the internal DC power feed to the module DC power connector. Refer to Figure 3-4. Securing Module in Slot and DC Connections Figure 3-4 NOTE: The RHU service module does not have an internal power feed connection. Inserting an RHU/AO Module in to QX Chassis I P/N 709C011101 I Page 15 3.4 Mounting 3.4.1 Rack Mount Installations 3.4.1.1 Plan the rack installation NOTE: The unit can also be wall mounted using dedicated brackets (ordered separately). For wall mounted units – it is recommended to install the service modules first. 1. Verify that the height of the rack can support QX unit being installed, as well as additional equipment, SCU-F, AC or DC power, and space for the broadband coax connection. Also consider room for future expansions. 2. If the SCU-F supports more than one QX chassis – install in between QX units. See Figure 3-5. 3. To maintain low center gravity, ensure that heavier equipment is installed near the bottom of the rack, and that the rack is loaded from top to bottom. QX and SCU-F Locations in Rack Figure 3-5 Mounting I P/N 709C011101 I Page 16 3.4.1.2 Rack Installation Safety Instructions Review the following guidelines to help ensure your safety and protect the equipment from damage during the installation. • Only trained and qualified personnel should be allowed to install or replace this equipment. • Verify that ambient temperature of the environment does not exceed 50°C (122°F) • To maintain a low center of gravity, ensure that heavier equipment is installed near the bottom of the rack and load the rack from the bottom to the top. • Ensure that adequate airflow and ventilation within the rack and around the installed components so that the safety of the equipment is not compromised. It is recommended to allow for at least about 2 cm of airspace between devices in the rack. 3.4.1.3 Mounting QX Unit in 19-IN Rack NOTE: The QX can also be mounted on wall – see section 3.4.2 Install the QX in the 19-in rack below the SCU-F (recommended) and secure with preassembled rack ears. 3.4.1.4 Mounting SCU-F Unit 1. Assemble the SCU-F Routing Bracket as follows: • Unscrew the two screws located on the far right of the SCU-F front panel. Save the screws for next step. • Assemble the supplied Routing Bracket on to the right side of the SCU-F front panel using the two screws previously removed. See Figure 3-6. SCU-F with Assembled Routing Bracket Figure 3-6 2. Install the SCU-F unit in the 19-in rack and secure with the factory-assembled rack ears. Mounting I P/N 709C011101 I Page 17 SCU-F Pre-assembled Rack Ears Figure 3-7 3.4.2 Wall Mount Installation There are two wall mount installation options for the QX unit, whereas the SCU-F can also be mounted on top of the QX chassis so as to accommodate connections between the units: a. Horizontal Wall Mount (provided with QX) - QX unit is mounted in a horizontal alignment so that the front panel interfaces face towards the front (as in rack installations). See 0. b. Vertical Wall Mount (ordered separately: P/N AK-QX-ENC-WMT-V) – QX unit is mounted in a vertical alignment so that the front panel interfaces face towards the side. See Figure 3-8. QX Vertical Wall Mount Alignment Figure 3-8 Mounting I P/N 709C011101 I Page 18 3.4.2.1 QX Horizontal Wall Mount Installation To mount the QX horizontally on the wall 1. Mark and drill the installation holes in the wall, using the bracket as a guide. There are two options, as shown in Figure 3-9: • Holes A1 and A2 are used for securing the brackets to the wall in a fixed position • Holes B2, B2 and B3 are used for hanging the assembly on anchors QX Horizontal Wall Mount Bracket Holes Figure 3-9 2. Assemble the brackets on to the QX unit by securing each bracket to the side of the QX chassis using (6) 6-32X5/16' Flat Head 100', Phillips screws (supplied) as shown in Figure 3-10. Horizontal Wall Mount Bracket Assembly Figure 3-10 Mounting I P/N 709C011101 I Page 19 3. Optional – mount the SCU-F unit on to the QX chassis: • Remove the QX side rack ears (pre-assembled) to access the holes required for assembling SCU-F • Secure each SCU-F bracket to the side of the QX chassis using the six (6) supplied screws, as shown in Figure 3-11. SCU-F to QX Assembly for Wall mount Figure 3-11 Installation 4. Mount the assembly on the wall using one (or both) of the mounting options - hang the QX on the anchors (previously prepared in wall) and/or secure to wall using the three (3) additional holes (screws not supplied). Horizontal Wall Mount Bracket Assembly – Rear View Figure 3-12 Note: When mounted on the wall, there will be approximately 60mm (2.36”) of space between the wall and the back of the QX unit. Mounting I P/N 709C011101 I Page 20 3.4.2.2 QX Vertical Wall Mount Installation Note: Vertical Wall Mount brackets are ordered separately (P/N AK-QX-ENC-WMT-V). To mount the QX vertically on the wall 1. Verify that the following items are included in the accessory kit: Item QTY. Vertical Wall Mount Bracket for QX chassis Screw,4-40X5/16',Flat-HD, 100', Philips, Nerosta Image 16 2. Remove the factory assembled rack ears from the sides of the QX chassis so as to access the relevant screw holes for assembling the QX vertical wall mount brackets. See Figure 3-13. QX Rack Ears Figure 3-13 Mounting I P/N 709C011101 I Page 21 3. Assemble the vertical wall mount brackets on to the sides of the QX chassis using the eight (8) provided screws, as shown in Figure 3-14 Vertical Wall Mount Bracket Assembly Figure 3-14 Note: You may want to mark the mounting holes on the wall (according to brackets) prior to mounting. 4. Select the appropriate location on wall for the QX unit. Verify that: • There is enough free space around the unit for ventilation • Location enables opening the enclosure door to the side 5. (If not already marked) Mark the mounting holes on the wall according to the bracket holes and drill appropriate holes. Mounting I P/N 709C011101 I Page 22 6. Optional – mount the SCU-F unit on to the QX chassis by securing each SCU-F bracket to the side of the QX chassis with the six (6) supplied screws, as shown in Figure 3-15. SCU-F to QX Assembly for Wall mount Installation Figure 3-15 7. Mount the QX chassis on the wall with the panel interfaces facing towards the side, as shown in Figure 3-16. QX (with SCU-F on top) Vertical Mount Installation – Front View Figure 3-16 Mounting I P/N 709C011101 I Page 23 3.5 Connections The system connections required for the QX consist of the following: • Fiber optic connections to the RF to fiber optic converter unit at the headend – BU or OCH • RF and Antenna connections: • RF service connections to the four port Service Combiner Unit (SCU-F) • Antenna connections between the SCU and the broadband antennas • (QX) AMU module connections to SCU • Power – Local (AC) or Remote (DC) The connections are described in the following sections. 3.5.1 QX Fiber Optic Connections Note: Keep in mind the rules for handling and connecting F/O cables. The F/O cables will be connected to the associated BU/OCH in the communication room at a later phase. To connect fiber optic cabling 1. (If not already installed) Install splice box near the QX chassis. 2. Referring to Figure 3-16, remove the tab (both parts) covering the fiber slot (located on port panel) and set aside. Route the fiber through the slot and connect to the RHU SC/APC To/From ports, Refer to Figure 3-18 . 3. Replace the fiber slot tab (both parts). Removing Fiber Slot Tab Figure 3-17 Connections I P/N 709C011101 I Page 24 Routing Fiber to Connection Port Figure 3-18 Note: See section 3.5.1.1 for MIMO connections to RF to Fiber optic converter unit (BU/OCH). 3.5.1.1 MIMO Configurations Two QX units supporting the LTE700 and AWS bands can provide MIMO service coverage. For MIMO configurations Connect the fiber optic port of each of the two QX units’ supporting the LTE 700 and AWS (SISO) bands to a different BU/OCH optic module (see section 3.5.1 for description of connections). See Figure 3-19 for example of MIMO connections to OCH. Note: Connections are the same between QX and Base Unit (BU) as for OCH. QX to OCH MIMO Connections Figure 3-19 Connections I P/N 709C011101 I Page 25 3.5.2 RF Connections This section provides information describing the following connections: • RF (SISO) and antenna monitoring connections between QX and SCU-F • MIMO connections between QX and SCU-F • SCU-F to broadband antenna infrastructure connections 3.5.2.1 QX RF and Antenna Monitoring Connections To connect the RF service and antenna connections (refer to Figure 3-20) 1. Connect the QMA to QMA RF jumper cables (provided with each ordered service module) to the service specific QX RF QMA connector. 2. Route the cables through the assembled SCU-F Routing Bracket (see 3.4.1.4). 3. Connect the other side of the jumper cables to the relevant SCU-F low band (ports 1-4) and/or high band (ports 5-8) QMA ports. The connections shown in Figure 3-20 show an example of connections performed for the CELL/PCS/700LTE/AWS services: • QX High-frequency band mobile service to SCU-F High Ports (1 - 4) (e.g. AWS and PCS) (shown in blue) • QX Low-frequency band mobile service to SCU-F Low Ports (5 - 8) (e.g. CELL and LTE700) (shown in red) IMPORTANT! Terminate any unused ports. NOTE: Refer to section 3.5.2.2for connections required for MIMO configurations. Connections I P/N 709C011101 I Page 26 04. Connect the QX internal AMU module (for antenna sensing) to the SCU by connecting the DB15 female connector to the corresponding SCU DB15 female connector, using corresponding cable provided with the SCU-F (P/N 705A042301). See Figure 3-20. QX RF and Antenna Connections Figure 3-20 Connections I P/N 709C011101 I Page 27 3.5.2.2 RF MIMO Connections to SCU-F Two QX units supporting the LTE700 and AWS bands can be deployed in a MIMO configuration. The LTE700 and AWS RF service ports of both QX units are connected to the corresponding low band and high band SCU-F ports. See Figure 3-21. QX RF and Antenna Connections Figure 3-21 Connections I P/N 709C011101 I Page 28 3.5.2.3 Daisy Chaining the AMU modules of Multiple QX Units to a Single SCU-F NOTE: If installing more than one QX unit, they can be interconnected so that the antenna sense function is performed by a single AMU (Antenna Monitoring Unit) located inside the QX unit. Connect one of the two front panel ANT. Sense1 RJ45 connectors of the QX unit directly connected to the SCU-F DB-15 port to the ANT. Sense1 port of the additional QX unit using the RJ45 to RJ45 cable provided with the QX (P/N 705900003). It is recommended to connect the ports closest to each other. See Figure 3-22. Daisy Chaining AMU to SCU-F Connections Figure 3-22 Connections I P/N 709C011101 I Page 29 3.5.2.4 SCU-F to Broadband Antenna Connections To connect the broadband antennas The QX is connected to the antenna infrastructure via the Service Combiner Unit (SCU-F). Connect the SCU-F front panel N-Type RF Antenna Ports to the broadband antennas. See Figure 3-23. Note: Terminate any unused antenna ports with 50 ohm terminators. SCU-F to Antennas Connections Figure 3-23 3.5.3 Grounding the QX Unit Ground the QX cabinet via the grounding lug located on the rear. QX Grounding Lug Figure 3-24 Connections I P/N 709C011101 I Page 30 3.5.4 Power Connections The QX supports both local powering (100-240VAC) and remote powering (25 to 48VDC) options. Both types of power cables are provided with the unit (see section 3.2). Connect the power source to the QX using either Local or Remote power (both are supported): AC In - Local Power: 100-240VAC (Integrated AC/DC converter) DC In - Remote Power: 25 to 48VDC Refer to for Figure 3-25 location of power connectors. QX Power Connection Interfaces Figure 3-25 Connections I P/N 709C011101 I Page 31 3.6 Verifying Normal Operation Upon powering up the QX remote unit: • Confirm the fans are working after powering • Verify normal operation: Module LED Description QX Power Steady Green: Required power is supplied to AMU module of QX chassis Off: No power supplied to AMU module of QX chassis Steady Green: AMU module SW initialized Blinking Green: AMU module SW is initializing (blinks for the duration of approx. 1 minute) Steady Green: Fan status normal Red: Faulty fan, alarm triggered Steady Green: Power input module Off: No power detected for RHU module Blinking Green: Active communication detected Red: Faulty communication link Steady Green: Normal optical BU/OCH-QX Blinking Green: Low optical link level from BU/OCHQX Off: No optical link is detected from BU/OCH-QX Steady Green: Power input detected for first/second Add-On unit Off: No power detected for first/second Add-On unit Steady Green: Boot up sequence for first/second Add-On unit complete and functioning Blinking Green: Boot up sequence for first/second Add-On unit in process Run Fan RHU Power Comm Link AO1/AO2 Power Run detected link for level RHU from Verifying Normal Operation I P/N 709C011101 I Page 32 LED Indication of Normal Operation Figure 3-26 Verifying Normal Operation I P/N 709C011101 I Page 33 4 Maintenance This section provides maintenance information on the following: • Replacing existing RHU/AO modules currently in QX chassis • Replacing the QX chassis fan modules (in case of faulty fans) 4.1 Replacing an RHU/AO Module This section describes how to replace an existing RHU and/or RHU/AO module. The RHU and AO modules are easily removed from/added to the QX chassis, while the procedure does not require powering off the unit (hot-swap). To Replace an RHU/AO Module 1. Open the QX door, by unscrewing the two screws. QX Front Door Screws Replacing an RHU/AO Module I P/N 709C011101 I Page 34 Figure 4-1 2. To remove a module: NOTE: For partial configurations, a “dummy” module is inserted in the unused service module slot. Does not include connections. • Disconnect F/O (RHU) or DC power connection (Add-On) – where relevant • Open the captive screws securing the module in place • Open the ejectors and Pull the module out (using the handle) Removing Service Module Figure 4-2 3. To insert a module – refer to section 0 4. Connect the F/O and power connections to the corresponding ports on the module front panel. 5. Close the QX chassis door and secure the screws. 6. Connect the relevant RF SMA connector, located on the QX front panel (door), to the SCU. 7. Configure new service via the SC-450 Controller (refer to SC-450 User Manual). Replacing an RHU/AO Module I P/N 709C011101 I Page 35 4.2 Replacing Fan Module In case of faulty fans, they are easily replaced while the procedure does not require powering off the unit (hot-swap). To replace faulty fan(s) 1. Unscrew the four screws securing the fan to the chassis door. See Figure 4-3. Unscrewing Fan Module Screws Figure 4-3 2. Pull out the fan module and disconnect the cable. See Figure 4-4. Disconnect cable Removing Existing Fan Module Figure 4-4 3. Connect new fan module. 4. Fit the new fan module into place in the chassis door, as shown in Figure 4-5. Replacing Fan Module I P/N 709C011101 I Page 36 Insert fan module so that the metal plates are on each side Inserting New Fan Module Figure 4-5 5. Tighten the four fan module screws so it is secured to the QX front door panel. Replacing Fan Module I P/N 709C011101 I Page 37 5 Appendix A: System Specifications RF Parameters Supported Services Technologies Band Frequency Range Uplink (UL) Downlink (DL) CDMA/WCDMA**/TDMA/GSM/LTE* CELL800 824-849 869-894 CDMA/WCDMA**/TDMA/GSM/LTE* PCS1900 1850-1915 1930-1995 WCDMA**/LTE* AWS1200 1710-1755 2110-2155 700 MHz 698-716 728-746 776-787 746-757 LTE (*)WCDMA service is based on 3GPP standards, LTE service may deployed in the future due to Frequencies re-farming planned by the Carriers as well (**)WCDMA service is based on 3GPP2 CDMA2000 standards. Replacing Fan Module I P/N 709C011101 I Page 38 RF Parameters per Service at Antenna Port of Four Port Service Combiner Unit (SCUF) The RF Parameters listed in the tables in this section reflect the specifications at each of the four antenna ports of the SCU-F when combined with the QX. RF Parameters QX RF Parameters at Antenna Port of SCU-F PCS CELL TDMA/CDMA/ CDMA/WCDMA/ WCDMA TDMA/GSM AWS 700 MHz WCDMA LTE DL UL DL UL DL UL DL UL 16 20 21 21 2 Operators 13 17 18 18 4 Operators 10 14 15 15 8 Operators 11 12 12 Operators 10 16 20 21 21 4*** Pin (dBm) Input IP3 (dBm) AGC OFF Min -5 Input IP3 (dBm) AGC ON Min -6 Input IP3 (dBm) -7 -10 SFDR2 (dB) 71 66 55 -13* -13* 64 ** 20 20 20 20 Max Output Power per Antenna Port 1 Operator (Composite) Mean Gain (dB) 1 Max Intermod Distortion (dBm) Max NF (dB) Gain Flatness/Ripple (dB) 3 ±2.0 ±2.0 ±1.0 * WCDMA compiles with 3GPP TS 25.106 V5.0.0 (2002-03) table 9.4 spectrum emission mask. ** Out of band and spurious emissions compliant to FCC. ***Default Conditioner (BTSC) UL Gain=+3dB Factory set mean gain BU-RHU without RIU. May be field adjusted using controller system. SFDR for CDMA services is calculated in 100KB/sec. Gain Flatness/Ripple is specified for the non-duplexed port of the system. Overall system typical values. Error! Use the Home tab to apply Heading 1 no numbering to the text that you want to appear here. I CMA-xxx-AEN I Page 39 Absolute Maximum Rating Total RF Input Power to BU/OCH 10 dBm Total RF Input Power to QX RHU Module 20 dBm out-of-band; -10 dBm in-band Optical Specifications Optical Output Power < 3.0 mW Max. Optical Budget 2 dB for fiber + 1 dB for connectors (assumed) = 3 dB total. 300 m Multi-mode Optical Loss per Mated-pair Connectors 0.5 dB (max) Optical Connectors SC/APAC Fiber Type Single Mode Fiber (SMF): 9/125 µm Multi Mode Fiber (MMF): 50/125 µm or 62.5/125 µm (Minimum qualifications with ANSI/TIA/EIA-568-B series, EN50173-1 or ISO/IEC 11801 Wavelength 1310 ± 10 nm Maximum Distance Between Base Unit and Remote Unit 2 km Environmental Specifications Operating Temperature -5°C to +55°C (23°F to 131°F) Storage Temperature -20°C to 85°C (-4°F to 185°F) Humidity 10% to 95%, non-condensing Error! Use the Home tab to apply Heading 1 no numbering to the text that you want to appear here. I CMA-xxx-AEN I Page 40 Standards and Approvals Laser Safety CDRH 21 CFR 1040.10, 1040.11 (Except for deviations per notice No.50, July 26, 2001) IEC 60825-1, Amendment 2 (January 2001) EN 60825-1 CE Radio Equipment and Systems EN 301 502 – for GSM / EGSM Frequency Bands EN 300 328 – for WLAN 802.11b/g 2.4GHz Frequency Band EN 301 893 – for WLAN 802.11a 5GHz Frequency Band EMC EN 301 489 FCC Radio Equipment and Systems: FCC 47 CFR Part 22, 24, 27, 90 EMC: FCC 47 CFR Part 15 Subpart B Safety EN 60950UL 60950 CAN/CSA-C22.2 No.60950 UL 2043 Error! Use the Home tab to apply Heading 1 no numbering to the text that you want to appear here. I CMA-xxx-AEN I Page 41 System Component Specifications Quad-Service Package (QX) Supported Services CELL850; PCS1900; LTE700; AWS2100 Ports To Service Combiner Unit (SCU): (4) 50Ω QMA ports To Base Unit/Optical Control Hub (OCH-QX): AMU Master-Slave connections (2) SC/APC ports Local connection to AMU module for SW DL (for service personnel): To SCU-4: (1) RJ45 port RS232 local connection to AMU module (for service personnel): (1) DB9 connector Power (2) RJ45 ports (1) DB15 connector Local Power: 100-240VAC (Integrated AC/DC converter) Remote Power: 25 to 48VDC Max Power Consumption: 118W Physical Dimensions Mounting: 19” Rack or Wall (pre-assembled brackets) 17.1x14.5x5.2 (in) 434x369x133 (mm) (WxDxH) Weight: ~40 lb (~18 kg) Cooling Features Active heat dissipation (Fan) Four - Port Service Combiner Unit (SCU-F) Supported Services High band (1710 MHz - 2170 MHz) and low band (698 MHz – 960 MHz) RF services Ports To QX: (8) 50Ω QMA connectors To Wideband antennas: (4) N-Type 50Ω connectors For local maintenance: (1) DB15 connector Physical Dimensions Mounting: 19” Rack (pre-assembled brackets) 17.04x1.72x10.63 (in) 434x440x270 (mm) (WxDxH) Weight: 6.6 lb (3 kg) Error! Use the Home tab to apply Heading 1 no numbering to the text that you want to appear here. I CMA-xxx-AEN I Page 42 6 Appendix B: Ordering Information NOTE: The information listed below is updated up to the document publishing date. Refer to the QX datasheet for the most updated ordering information. QX Chassis and Modules Part Number Description 2000-QX-B-QC QX Chassis without Public Safety Support (termination modules not included; no coexistence with Public Safety) 2000-QX-B-QCF QX Chassis with Public Safety Support (termination modules not included; supports coexistence with Public Safety) 2000-C85P19-B-RHM QX Cell & PCS SISO Remote Hub Module (with Single-Mode Fiber Support) 2000-C85P19-B-RHM QX Cell & PCS SISO Remote Hub Module (with Multi-mode Mode Fiber Support) 2000M-C85P19-B-RHM QX LTE SISO Add-on module; 2000-L70-B-AM QX AWS SISO Add-on module 2000-A17-B-AM QX Cell & PCS SISO Remote Hub Module (with Single-Mode Fiber Support) QX Accessory Kits Part Number Description 2000-QX-B-FAM QX field replaceable Fan 2000-SCU-8-4-F 8 x 4 Service Combiner Unit with all connectors in the front 2000-L70-B-TM QX LTE SISO Add-on port termination module; 2000-A17-B-TM QX AWS SISO Add-on port termination module; AK-QX-ENC-WMT-V QX mounting brackets and screws to mount the chassis flush to the wall Error! Use the Home tab to apply Heading 1 no numbering to the text that you want to appear here. I CMA-xxx-AEN I Page 43
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Mira Perez Create Date : 2013:01:20 11:52:03+02:00 Modify Date : 2013:01:20 14:08:09+02:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2013:01:20 14:08:09+02:00 Creator Tool : Acrobat PDFMaker 9.0 for Word Document ID : uuid:1ce13bc8-7585-4dbe-8e8d-c19d8da74c0d Instance ID : uuid:5e8486c8-6872-40ba-bbbb-c2d18145500c Subject : 11 Format : application/pdf Creator : Mira Perez Producer : Adobe PDF Library 9.0 Source Modified : D:20130120095144 Tag Ad Hoc Review Cycle ID : 2075307393 Tag Email Subject : to Mira... Tag Author Email : michall@e-glue.com Tag Author Email Display Name : michal livne Page Layout : OneColumn Page Count : 51EXIF Metadata provided by EXIF.tools