Coway Chp 03Al Users Manual

CHP-03AR to the manual a0189081-81b8-4b16-9547-81113e71c78a

2015-02-05

: Coway Coway-Chp-03Al-Users-Manual-531479 coway-chp-03al-users-manual-531479 coway pdf

Open the PDF directly: View PDF PDF.
Page Count: 42

CHP-03AR/L/U
Water Filtration Device
• Thisproductcannotbeusedifthevoltageisdierentfromthat
mentionedintheratingplate.
• Foryoursafetyandproperuseoftheproduct,pleasereadthis
User’sManualbeforeuse.
• WarrantycardisincludedinthisUser’sManual.
FEATURES
1. Power saving function using the light sensor
Ifyoupressthe"Sleep"button,asitdecreasesthedrivingtimes
ofthemotorandtheheateratnightautomatically,theamountof
thepowerconsumptionisdecreased.
2. Booster pump for boosting the main water
(CHP-03AR)
Itequippedtheboosterpumptoshowtheuniformltering
abilitiesintheregionwiththelowmainwaterpressure.
3. Low water level detecting function
Itdecreasesthepowerconsumptionbystoppingtheworkingof
themotorandtheheaterwhenthewaterlevelinthedtoragetank
isloweredduetothewaterfailure.
4. Front draining system
Itisconvenientasitcandrainthehotwaterfromthefrontside
withoutmovingtheproductwhenyouopenthefrontdrainingdoor.
5. Fine particles ltering system
Itminimizedtheamountoftheneparticlethatcanbeenteredinto
thewatertankbyequppingtheinno-sencelter.
Sleep
Water Level
Sleep
Water Level
Sleep
Water Level
Sleep
Water Level
Booster
Pump
1
DEAR CUSTOMERS
Thankyouforusingour
Coway Water Filtration Device.
PleasereadthisUsersManualtouseandmaintaintheproductcorrectly.
Ifyouencounteraproblemwhileusingtheproduct,youmaysolvetheproblemreferringto
theUser’sManual.Asthismanualcontainstheproductwarrantycard,pleasekeepitinasafe
place.Thissystem(CHP-03AR/L/U)conformstoNSF/ANSI42foraestheticchlorinereduction
andNSF/ANSI53forVOCreductionasveriedandsubstantiatedbytestdata.
Thissystem(CHP-03AR/L)conformstoNSF/ANSI58forthereductionofpentavalentarsenic,
barium,cadmium,selenium,radium226/228,trivalentchromium,hexavalentchromium,lead,
nitrate/nitriteasveriedandsubstantiatedbytestdata.
Thissystem(CHP-03AR/L)registeredinCalifornia.
Seeperformancedatasheetforindividualcontaminantsandreductionperformance.
Thissystem(CHP-03AR/L)isacceptablefortreatmentforinuentconcentrationsofnomore
than27mg/Lnitrateand3mg/LnitriteincombinationmeasuredasNandiscertiedfor
nitrate/nitritereductiononlyforwatersupplieswithapressureof280kPa(40psi)orgreater.
CONTENTS
MAINTENANCE
INSTALLATION ..........................19
CLEANING METHOD ....................21
Storagetank..........................21
Gutter................................23
FILTER REPLACEMENT ...................24
FILTER REPLACEMENT METHOD .........25
OTHERS
TROUBLESHOOTING ....................27
SPECIFICATION .........................28
WATER FLOW DIAGRAM .................29
PERFORMANCE DATA SHEET ............30
WARRANTY CARD .......................39
FOR INFORMATION
SAFETY INFORMATION ...................3
Electricitysafety....................... 3
Installationsafety...................... 4
Operationsafety....................... 5
Others................................. 6
PARTS NAME ............................7
WATER FILTRATION PROCESS .............8
HOW TO USE
INSTALLATION PRECAUTIONS ...........12
OPERATION / INDICATION PART . . . . . . . . . 14
HOW TO USE ............................17
Todrinkthecoldwater................17
Todrinkthehotwater ................17
Todrinktheroomwater ..............18
- Please keep the User’s Manual where it can be readily reached or found -
Coway
FEATURES / CONTENTS
2
SAFETY INFORMATION
Electricity safety
Do not pull the power
cord.
Otherwise,electricshockor
remayoccurasaresult.
Do not touch the power
plug with a wet hand.
Otherwise,electricshockor
remayoccurasaresult.
Do not connect and
pull out the power plug
repeatedly.
Otherwise,electricshockor
remayoccurasaresult.
Unplug the product
before repair, inspection,
or parts replacement.
Otherwise,electricshockor
remayoccurasaresult.
Do not use a damaged
power cord or plug, and
loose outlet.
Otherwise,electricshockor
remayoccurasaresult.
Do not carry the unit by
its power cord.
Otherwise,electricshockor
remayoccurasaresult.
Do not forcefully bend the
power cord or put it under
a heavy object to prevent
it from being damaged or
deformed.
Otherwise,electricshockor
remayoccurasaresult.
If the electric outlet is wet,
carefully unplug the unit
and let the electric outlet
completely dry before
subsequent use.
Otherwise,electricshockor
remayoccurasaresult.
Be careful to keep this safety information.
Pleasereadthisinformationtopreventpropertylossandensureyoursafety.
Ifnotobserved,
seriousinjuryor
evendeathcould
occur.
Ifnotobserved,
seriousinjuryor
propertydamage
couldoccur.
Ifnotobserved,slight
injuryorproperty
damagecouldoccur.
Danger Warning Caution
3
Avoid installing the
system in places where
the air is damp, dust is
accumulated, or water
drops.
Otherwise,electricshockor
remayoccurasaresult.
Do not attempt to repair
or modify the power cord
at your discretion.
Otherwise,electricshockor
remayoccurasaresult.
Do not plug into an
outlet that is being used
by several other
appliances. Use an
electrical outlet dedicated.
Otherwise,remayoccuras
aresult.
Do not install the product
on a sloped oor.
Injurytotheuserordamage
totheunitmayresult.
Installation safety
Do not place or use the
Inammable gases, nor
the ammable materials
near the product.
Otherwise,electricshockor
remayoccurasaresult.
Do not install near a
heating device.
Otherwise,remayoccuras
aresult.
Do not press the product
by constraint or impact.
Injurytodamagetotheunit
mayresult.
SAFETY INFORMATION | Electricity safety | Installation safety
For Information
When you don’t use for a
long time, close the main
water supply valve and
unplug.
Otherwise,electricshockor
remayoccurasaresult.
In the case the power cord
is damaged, do not replace
the cord yourself. Call
Coway Service Center to
have it replaced.
Otherwise,electricshockor
remayoccurasaresult.
Remove any dust or water
o in the pin and contacts
of the power plug.
Otherwise,electricshockor
remayoccurasaresult.
The ltration device installation shall
comply with applicable state and local
regulations.
4
SAFETY INFORMATION
To drink the ltered
water, change the lter
according to the lter
replacement cycle.
Ifyouusetheexpiredlter,
thelterperformanceis
lowered.
Do not put the candle, a
light for cigarette on the
products.
Otherwise,remayoccuras
aresult.
When the water is coming
inside of the product or
there is a puddle on the
product, call Service Center
after closing the supplying
valve and unplugging.
Otherwise,electricshockmay
occurasaresult.
Do not allow hot water to
come in contact with the
human body.
Otherwise,burnmayoccurasa
result.
Operation safety
Do not place any
containers with water,
medicine, food, small
metallic objects, or any
ammable material on
the top of the product.
Inthecaseforeignmaterial
getsinsidetheproduct,
electricshock,re,product
damagemayoccurasaresult.
If our product produces a
strange noise or odd smell,
immediately unplug from
the electrical outlet and
call our Service Center.
Otherwise,electricshockor
remayoccurasaresult.
Use after closing the water
tank cover completely
inside of the product.
Thebuckortheforeignbody
canbeentered.
When you don’t use for a
long time, use after draining
the saved water completely
and emptying the newly
room water once again.
Thesavedwatercanbe
polluted.
Ifnotobserved,
seriousinjuryor
evendeathcould
occur.
Ifnotobserved,
seriousinjuryor
propertydamage
couldoccur.
Ifnotobserved,slight
injuryorproperty
damagecouldoccur.
Danger Warning Caution
5
Others
Do not clean by spraying
the water directly or don’t
wipe the product using the
benzene and thinner.
Otherwise,electricshockor
remayoccurasaresult.
Do not use ltered water
for the water exchange of
an aquarium or a shbowl.
Theroomwaterthroughthe
membraneisn’tsuitablefor
thesh’slifeenvironmentas
itremovedtheionicmaterial.
Insomecases,shesmight
evendie.
Clean after unplugging.
Otherwise,electricshockor
remayoccurasaresult.
Do not repair,
disassemble,
or modify.
Otherwise,electricshockor
productdamagemayoccur
asaresult.
After moving the product
or replacing the inno-
sense lter, the black
powder can be remained
in the inner bottom of
the water tank.
Itisquietharmlessasthe
powderoftheactivated
carbonusedinthe
inno-senselterwasowed
outforimprovingthewater
tastes.
Do not use with water
that is microbiologically
unsafe or of unknown
quality without
adequate disinfection
before or after the
system.
Rotate with grasping the
room water extraction
faucet or don’t raise the
product using the faucet.
Otherwiseleakageor
productdamagemayoccur
asaresult.
Danger Warning Caution
SAFETY INFORMATION | Operating safety | Others
For Information
6
PARTS NAME
Front
Rear
Cup-touch lever
Hot water safety button
Front draining door
Jog shuttle
Hot water safety faucet
Indication part
Gutter
Operation part
Cold/Room water
Changeover faucet
Front cover
Top cover
Rear cover
Power cord
Radiator
Outlet(Blue, CHP-03AR/L)
Inlet(Orange)
7
WATER FILTRATION PROCESS
STEP 1, 2 : NEO-SENSE FILTER
STEP 3 : RO MEMBRANE FILTER
STEP 4 : INNO-SENSE FILTER
STEP 5 : CERAMIC FILTER
Thisneo-senselterhasthefunctiontoreduceaestheticchlorine,odor,volatile
organiccompounds(VOC's).
ROmembranelterhasthefunctiontoreducewatercontaminantssuchaspentavalentarsenic,
barium,cadmium,selenium,radium226/228,trivalentchromium,hexavalentchromium,lead,
nitrate/nitrite.
Thisinno-senselterhasthefunctionstoreducesmellinductionmaterialandtoimprovetasteof
water.Italsohasthefunctiontoreduceaestheticchlorine,volatileorganiccompounds(VOC's).
The 5-step water ltering system (CHP-03AR/L)
Thelteristhecoretechnologyoftheltrationsystem.
Ifyoudon’tusequalifyinglterorifyouuseanoldlterthathasexpired,thesystem
performancemaydegrade.
Disposed
WaterOutlet
NEO-SENSE
FILTER
ROMEMBRANE
FILTER
CERAMIC
FILTER
INNO-SENSE
FILTER
CERAMIC
FILTER
PARTS NAME / WATER FILTRATION PROCESS
For Information
Uses of disposed water
- Thedailylifewatershouldbeusedforcleaningtherestroom,thehouse,clothes,or
purposesotherthandrinking.
- Neverusethedailylifewaterforadrinkingwateroracook.
Tips
8
WATER FILTRATION PROCESS
STEP 1, 2 : NEO-SENSE FILTER
STEP 3 : RO MEMBRANE FILTER
STEP 4 : POST-CARBON FILTER
STEP 6 : CERAMIC FILTER
STEP 5 : FINE FILTER
Thisneo-senselterhasthefunctiontoreduceaestheticchlorine,odor,volatile
organiccompounds(VOC's).
ROmembranelterhasthefunctiontoreducewatercontaminantssuchaspentavalentarsenic,
barium,cadmium,selenium,radium226/228,trivalentchromium,hexavalentchromium,lead,
nitrate/nitrite.
Thispost-carbonlterhasthefunctionstoreducesmellinductionmaterialandtoimprovetasteof
water.Italsohasthefunctiontoreduceaestheticchlorine,volatileorganiccompounds(VOC's).
Thisnelterhasthefunctiontoreduceneparticlesinthewater.
The 6-step water ltering system (CHP-03AR/L)
Disposed
WaterOutlet
NEO-SENSE
FILTER
ROMEMBRANE
FILTER
FINE
FILTER
CERAMIC
FILTER
POST-CARBON
FILTER
CERAMIC
FILTER
9
STEP 1, 2 : NEO-SENSE FILTER
STEP 3 : INNO-SENSE FILTER
STEP 4 : UF MEMBRANE FILTER
STEP 5 : CERAMIC FILTER
Thisneo-senselterhasthefunctiontoreduceaestheticchlorine,odor,volatile
organiccompounds(VOC's).
Thisinno-senselterhasthefunctionstoreducesmellinductionmaterialandto
improvetasteofwater.Italsohasthefunctiontoreduceaestheticchlorine,volatile
organiccompounds(VOC's).
The 5-step water ltering system (CHP-03AU)
NEO-SENSE
FILTER
INNO-SENSE
FILTER
CERAMIC
FILTER
UFMEMBRANE
FILTER
CERAMIC
FILTER
WATER FILTRATION PROCESS
For Information
10
WATER FILTRATION PROCESS
STEP 1, 2 : NEO-SENSE FILTER
STEP 3 : POST-CARBON FILTER
STEP 4 : UF MEMBRANE FILTER
STEP 5 : CERAMIC FILTER
Thisneo-senselterhasthefunctiontoreduceaestheticchlorine,odor,volatile
organiccompounds(VOC's).
Thispost-carbonlterhasthefunctionstoreducesmellinductionmaterialandto
improvetasteofwater.Italsohasthefunctiontoreduceaestheticchlorine,volatile
organiccompounds(VOC's).
The 5-step water ltering system (CHP-03AU)
NEO-SENSE
FILTER
POST-CARBON
FILTER
CERAMIC
FILTER
UFMEMBRANE
FILTER
CERAMIC
FILTER
11
INSTALLATION PRECAUTIONS
The summary for the proper installation of the water ltration device
1. Close main water supply valve to separate the faucet.
2. Wind the teon tape on the adaptor and t it to the
pipe.
3. Connect the faucet with the adaptor.
4. Connect 1/4 inch orange tubing with the connector
on the adaptor.
5. Open the feed valve to supply water to the ltration
system.
Do not tum the water pipe.
Shall install the adaptor with connector on the cold water
pipe.
Flush water through each lter at least 5 minutes before
Connection.
WATER FILTRATION PROCESS / INSTALLATION PRECAUTIONS
For Information
12
INSTALLATION PRECAUTIONS
Please check before use!
This product is for 120 V~ 60 Hz only.
Pleaseconnectthepowerplugtoadedicatedgroundedelectrical
outletfor120V~60Hz.Thewaterltrationdeviceworksnormally
onlywhentheelectricityisconnected.
• Openthemainwatersupplyvalve.
Themainwatermustbesuppliedtooperatethewaterltrationdevicenormally.
• Afterinstallingtheproduct
Getridofthesavedwaterabovethefullwaterintheinnerwatertank2timesormoretouse.
• Whentheindicatorintheindicationpartisturnedo
Whentheindicatorintheindicationpartisturnedo,checkifthepowersupplywasstopped
duetothepowerfailureorothercause.
• Regularlylterreplacement
Itisimportanttoreplacethelterregularlytodrinkthepurewater.Ifthelterisoverused
beyonditsservicelife,theperformanceofthewaterltrationdevicedeteriorate,Donotmissthe
lterreplacementcycle.
• Whenyoudidn’tuseforalongtime
Ifyousavedthewaterforalongtimeoryoudidn’tuse,drainthewaterinsideofthewater
ltrationdevicecompletelyandremovethenewlylteredwateronetimetouse.
• Whenyoudon’twanttouseforalongtime
Closethemainwatersupplyvalveandunplug.
• Draininghotwater
Slidethedrainingcoveratthefrontoftheproductoandconnectthedraininghose
(continuousextractionhose)todrainthehotwaterinthehotwatertank.
(Takecarenottoburnyourselfwhendrainingthehotwater.)
Whenyoudon’tuseforalongtime,closethemainwatersupplyvalveandunplug.
Tips
13
INSTALLATION PRECAUTIONS / OPERATION/INDICATION PART
How to Use
OPERATION / INDICATION PART
Indication part/Operation part
Indicationpart Operationpart
Power
cut
Water
level
Coldwaterfunctionindicator
Waterlevelindicator
ColdwatertemperatureindicatorSleepmodeindicator
Hotwaterfunction
indicator
Hotwater
temperatureindicator
1
4 6
5
23
1
Hot water function
indicator
Whenyouselecthotwater
mode,theindicatoristurned
on.
3
Water level indicator
Theindicatorislightened
accordingtothewaterlevel
ofthestoragetank.
Ifyouconnectthewater
ltrationdevice,oneblankis
lightenedbasically.
5
Cold water function
indicator
Whenyouselectcoldwater
function,theindicatoris
turnedon.
6
Cold water
temperature indicator
Theindicatoristurnedonaccording
tothecoldwatertemperature.As
manyindicatorsareturnedon,the
coldwaterbecomescoldmoreand
more.
4
Sleep mode indicator
Whenyouselectsleepmode,the
indicatoristurnedon.
2
Hot water temperature
indicator
Theindicatoristurnedonaccording
tothehotwatertemperature.As
manyindicatorsareturnedon,the
hotwaterbecomeshotmoreand
more.
14
OPERATION / INDICATION PART
Operation part
Cold water function
selection button
Whenyouwanttoselect/
deselectcoldwater
function,useit.
1 Hot water function
selection button
Whenyouwantto
select/deselectHot
waterfunction,useit.
2
Sleep mode
selection button
Whenyouwishtoselect/
deselectsleepmode,
useit.
3 Light sensor
Itisthesensorsensing
thelightaroundthe
product.
4
Power
cut
Water
level
Sleepmode
selectionbutton
Hotwaterfunction
selectionbutton
Lightsensor
Coldwaterfunction
selectionbutton
1
2
3
4
15
OPERATION/INDICATION PART
How to Use
To use the cold water function
Pressthecoldwaterfunctionselectionbuttonand
checkifcoldwatermodeindicatorintheindication
partisturnedon.Ifyouwanttoturnothecoldwater
mode,presstheselectionbuttonforseveralseconds.
Youcandrinkthecoldwaterwhenyouturnonthe
coldwaterfunctionandabout1hourispassed.
To use the hot water function
Pressthehotwaterfunctionselectionbutton,checkif
thehotwaterfunctionindicatorintheindicationpartis
turnedon.Ifyouwanttoturnothehotwatermode,
pleasepresstheselectionbuttonforseveralseconds.
Youcandrinkthehotwaterwhenyouturnonhot
waterfunctionand30minutesispassed.
To use the sleep mode
Whenyoupressthesleepmodeselectionbutton,as
thesleepmodeindicatoristurnedonandthenumber
ofthemotordrivingisdecreasedatnight,thepower
consumptionisdecreased.
Whenthesleepmodeisoperated,thecoldwater
becomelesscool.
16
HOW TO USE
To drink the hot water
Press the hot water selection button and check the lightening status in the
hot water function indicator.
Press the cold water selection button and check the lightening status in the
cold water function indicator.
Turnthejogshuttletotheleftinthecoldwater/room
waterchangeoverfaucetandpushthecup-touchlever.
Pressthehotwatersafetybuttonandpushthe
cup-touchlever.
Hotwater
safety
button
(PUSH)
Ifthecoldwaterdoesn’tcomefromthewaterltrationdevice,checkifthecoldwater
modeindicatorintheindicationpartisturnedon(SeeP.16).
Tips
Ifthehotwaterdoesn’tcomefromthewaterltrationdevice,checkifthehotwater
modeindicatorintheindicationpartisturnedon(SeeP.16).
Tips
To drink the cold water
17
To drink the room water
Turnthejogshuttletotherightinthecold
water/roomwaterchangeoverfaucetandpush
thecup-touchlever.
HOW TO USE | To drink the cold water | To drink the hot water | To drink the room water
How to Use
18
INSTALLATION
Follow the instruction for installation
Mainwater
supplyvalve 2coolingstopper
120V~60HzOnly
Inlettubing(Orange)
Outlettubing
(Blue,CHP-03AR/L)
Connecttheorangecolorinlettubing 1tothe
tapwatersupplyingpipe.Connectingtheoutlet
tubing 2.
1
2
19
Be cautious!
Water ltration device installation place 1
Pleaseinstallthewaterltrationsystemnotataroughplace,adamp
place,aplacewheretheunitisexposedtothedirectsunlight,aplace
wheredustispresent,oraplacethatthewaterdrops.
Water ltration device installation place 2
Pleaseinstallattheplacewhereitis10cmormoreofromthewall
andthebottomisatandrm.
After installing the water ltration system
Getridofthelteredwaterabovethefulledwater2timesormore
necessarilyafterinstalling.
Cold water plumbing
Pleaseconnecttothecoldwaterpipenecessarily.
(Ifyouconnecttothewarmwaterpipe,theltercanbedamaged.)
Movement and installation
Whenthepositionismoved,connectthepowercordwhen30minutes
passesafterinstalling.
Tomaintainoptimalproductperformance,consultaCowayengineerforthedetailed
installationmethods.
Theremaybesomewaterremaininginsideofthelterwhichwasusedtotestthe
productduringinspectionprocessatthefactory.
Pleasefeelateasyanduseasitisn’ttheusedproduct.
Don’treusethemainwatersupplyvalveandhosethatwaspreviouslyusedwhen
youinstalltheproduct.
Tips
Afte r 3 0
minu t es
Hot water X
INSTALLATION
Maintenance
20
CLEANINGMETHOD
Storage tank
3. Open the upper cover of the product and open the storage tank cover.
1. Turn o by pressing cold water/hot water mode
selection button in the front of the product for
2~3 seconds or more and unplug the power
cord. Close the main water supply valve.
2. Drain the water inside of the water ltration device completely
using the draining hose and the cold water/room water changeover faucet.
Pleasedrainthewaterinthecoldwater/roomwatertank
fromthecoldwater/roomwaterextractionfaucetanddrain
thewaterinthehotwatertankfromthefrontdrainhole.
(SeeP.13forthehotwaterdrainingmethod)
21
CLEANING METHOD | Storage tank
Maintenance
6. Use the storage tank after cleaning it with the taken water, draining
completely using the draining hose, and emptying the newly ltered water
one time or more.
5. Please wipe the surface of the storage tank with
soft clothes.
4. Shake and clean a ceramic lter in the taken water by rotating and
separating it from the cold water/room water separation membrane
.
7. Close the storage tank cover after rotating and equipping the ceramic lter
in the cold water/room water separation membrane.
22
CLEANING METHOD
8.
Open the main water supply valve after closing
the upper cover and plugging the power cord.
Please operate the water ltration device
again by pressing cold water/hot water mode
selection button in the front of the product after
checking if the water is coming from the cold
water/room water extraction faucet and the hot
water extraction faucet.
Gutter
1. Gutter separation method
2. Gutter assembling method
Ifyoupullthefrontpartofthegutter,itisseparated
easily.
Youjustpushthehookofthegutterslightlyafter
stickingtotheproduct.
Closethestoragetankcovercompletely.
Awormoraforeignbodycanbeentered.
Whenyoucleanthestoragetank,don’tusethemedicineorthe
detergent.
Ifyoudon’tcleanthemedicineorthedetergentcleanly,itcanbe
harmfultothebody.
- Keepthesurroundingscleanlyandcleanthestoragetankonce
pertwomonths.
Tips
23
CLEANING METHOD | Gutter / FILTER REPLACEMENT
Maintenance
FILTER REPLACEMENT
Filter
Thelifeofthewaterltrationsystemisthelter.Itisn’tthelegitimated
lteroryouusetoolongevenifitisthelegitimatedlter,thelter
performancecanbelowered.
Pleasechangetothelegitimatedlteraccordingtothereplacementcycle.
Filter replacement cycle
Ifthelterisnotregularlyreplaced,itmaydegradethewaterqualityfrom
theproduct.Thelterreplacementcycledependingonthemainwater
qualitycanbeshortenedraterthantheexpectedreplacementcycle.
Theperiodforthelterexchangeismadebasedon10Luseinadayfor
houseuse(4peoplebased)and20Luseforbusiness.
CHP-03AR
Part No. Names of Filter Usable Period
WJNF11 Neo-senselter 6months
WJMF11-50 ROMembranelter(CHP-03AR) 24months
WJMF11-30-S ROMembranelter(CHP-03AL) 24months
WJIF11
/WJCF11-POST
Inno-senselter
/Post-carbonlter 18months
WJFF7 Finelter 18months
WJCC-02 Ceramiclter 12months
CHP-03AU
Part No. Names of Filter Usable Period
WJNF11 Neo-senselter 6months
WJIF11
/WJCF11-POST
Inno-senselter
/Post-carbonlter 18months
WJMF11-UF Ufmembranelter 12months
WJCC-02 Ceramiclter 12months
About lter replacement cycle
Thelterreplacementcycledescribedaboveisnotthelterquality
warrantyperiodbuttheexpectedcycle(life)thattheltershowsitsoriginal
performance.
Therefore,thelterreplacementcyclemaybereducedfortheareawiththe
poorwaterqualityormoreapplication.
24
FILTER REPLACEMENT METHOD
2. Remove the gutter, and separate the front cover by pressing down, and
unplug and separate all the cables connected completely.
(If the water in the storage tank remains, close the cold water/room water
changeover faucet using the stopper inside of the upper cover
and separate the front cover.)
1. Close the main water supply valve after unplugging the power cord, and
drain the water inside of the water ltration device (See P.21).
1
2
3
4
5
25
FILTER REPLACEMENT METHOD
Maintenance
3. After separating the tting connected to the lter trying to replace, please
replace the lter. (Separate the tting using the proper tool.)
4. After connecting all the separated cables, t a groove in the front cover and
close with pressing it down.
Bychangingthelterandconnectingthettingandthehoseprecisely,checkthat
thereisnoleakageanddraintherstlteredwaternecessarily.
Tips
Pleasebesuretousethenewlteraftercleansing.
- Neo-senselter:PleaseassembleaftercleansingwithNeo-senselterforabout
30seconds.
- Postcarbon/Fine/Inno-sense/Membranelter(RO):
PleaseassembleaftercleansingwiththemainwaterpassedNeo-senselterfor
about3minutes.
Tips
26
TROUBLESHOOTING
Thewaterltrationdevicemayoperateabnormallyduetominorcausesnotbecauseofthe
productmalfunctionbutbecauseofthefactthattheuserisnotfamiliarwiththeproductuse.
Insuchacase,problemscanbesolvedeasilyevenwithoutthehelpfromtheServiceCenterby
checkingthefollowingitems.Ifyoucan’tsolvetheproblemaftercheckingthefollowingitems,
pleasecalltheServiceCenter.
Symptom Check Measures to take
Thewatertastes
weird.
• Didyoucleanthestoragetank? Cleanthestoragetank.
• Youdidn’tusethewaterltrationdevice
foralongtime.
Getridofthesavedwaterandcleanthe
storagetank.
• Isn’titabouttimetochangethelter? Requestthelterreplacement.
Thewaterdoesn’t
come.
• Isthewatersupplycutorisn’tthewater
supplyvalveclosed? Openthemainwatersupplyvalve.
• Didyoumissthelterreplacementtimes? Requestthelterreplacement.
Thewateris
owingslower.
• Isn’titabouttimetochangethelter? Requestthelterreplacement.
• Isthepowerconnected? Checkifthepowercordplugin120V~60
Hzoutlet.
• Didn’tyouclosethemainwatersupply
valve? Openthemainwatersupplyvalve.
• Didn’tthetemperatureofthemainwater
dropsuddenly?
Ifthewatertemperatureislowered,the
wateramountisdecreased.
Thecoldwater
doesn’tcome.
• Wasthecoldwatermodeindicator
lightened?
Pleasepressthecoldwatermodeselection
button.
• Didn’tyouclosethemainwatersupply
valve?
Ifitisthelowwaterleveltoprotectthe
electricmotor,thecoolingfunctiondoesn’t
operate.Openthemainwatersupplyvalve.
• Isn’tthebacksideofthewaterltration
deviceandthewalltooclose?
Pleasekeepthedistancebetweentheback
ofthewaterltrationdeviceandthewallto
10cmormore.
Alloperationwas
stoppedsuddenly
whendriving.
• Isthemainwaterbeingsuppliedactively? Checkthemainwatersupplyvalve.
• Isthepowerconnected? Checkifthepowercordplugin120V~60
Hzoutlet.
• Isn’twateroverowingorleaking? RequestA/S.
27
SPECIFICATION
Product Water Filtration Device
Model CHP-03AR CHP-03AL CHP-03AU
FiltrationMethod RO(ReverseOsmosis) UF
PowerSupply 120V~60Hz
Tank
Capacity
RoomWater 6.59L
ColdWater 3.61L
HotWater 1.2L
Total 11.4L
Dimension 344mm(W)×540mm(D)×525mm(H)
WorkingTemperature 5°C-35°C
ProductionRate 190L/d(25°C,414kPa) 113L/d(25°C,138kPa) 1500L/d(25°C,108kPa)
WorkingPressure 69kPa–827kPa 138kPa–827kPa 69kPa–827kPa
NetWeight 22.3kg 19.8kg 19.8kg
• Thewateramountcanbedierentiatedaccordingtothewaterpressureandthewater
temperature.
• Thewatertankcapacityistheamountbythesizeandcanbedierentfromtheextraction
capacity.
• Withoutanypriornotice,allorpartsoftheproductaresubjecttochangeforthepurposeof
improvingtheperformanceoftheproduct.
• Refertoperformancedatasheetforindividualcontaminants,reductionperformanceandgeneral
operatinginformation.
TROUBLESHOOTING / SPECIFICATION
Others
28
WATER FLOW DIAGRAM
CHP-03AR
CHP-03AL
CHP-03AU
• Apostcarbonltermaybeinstalledinsteadofaninno-senselter.
Fortheprecisespecicationsofyourproduct,refertothedataplateontheproduct.
29
WATER FLOW DIAGRAM / PERFORMANCE DATA SHEET | CHP-03AR
Others
Water Filtration System Performance Data Sheet
Brand: Mach Model: CHP-03AR
ThissystemhasbeentestedandcertiedbytheWaterQualityAssociationaccordingtoNSF/ANSI42,53,and58for
thereductionofthesubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwaterenteringthe
systemwasreducedtoaconcentrationlessthanorequaltothepermissiblelimitforwaterleavingthesystem,as
speciedinNSF/ANSI42,53,and58.
Substance
Max.Allowable
Concentration
(mg/L)
Average
Inuent
(mg/L)
Average
Euent
(mg/L)
Minimum
Percent
Reduction(%)
Average
Percent
Reduction(%)
Arsenic(Pentavalant) 0.010 0.05 0.006 79.1 87.7
Barium 2.0 10 1.4 83.5 86.6
Radium226/228 5pCi/L 25pCi/L 5pCi/L N/A N/A
Cadmium 0.005 0.031 0.002 89.0 92.7
Chromium(Hexavalent) 0.1 0.358 0.023 93.8 95.1
Chromium(Trivalent) 0.1 0.367 0.028 93.8 95.7
Lead 0.010 0.153 0.005 93.6 95.1
Nitrate/Nitrite 10 29.6 4.8 78.5 83.7
Selenium 0.05 0.117 0.003 96.0 97.8
TDS <187.5 741.5 27.7 95.7 96.3
AestheticChlorine
INNOSENSE ≥50% 2.07 0.56 54.53 72.8
POSTCARBON ≥50% 1.96 0.53 55.0 72.8
VOC*
INNOSENSE ≥95%reduction 0.32 0.0077 95.70 97.6
POSTCARBON ≥95%reduction 0.298 0.005 96.0 98.3
Whiletestingwasperformedunderlaboratoryconditions,actualperformancemayvary.
General Operating Information:
RatedCapacity
INNOSENSEFILTER 229gallons(forVOC)
6,103gallons(forAestheticChlorine)
POST-CARBONFILTER 212gallons(forVOC)
1,179gallons(forAestheticChlorine)
Min-Maxoperatingpressure: 10~120psi(0.7~8.4kgf/cm2)
Min-Maxfeedwatertemperature: 41~95ºF(5~35ºC)
RatedServiceFlow 0.07GPM(forVOC)
0.5GPM(forAestheticChlorine)
DailyWaterProductionRate 82.3GPD
ProductEciencyRating 39.2%
ElectricalRequirements: 120Vac/60Hz
• Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfection
beforeorafterthesystem.
• Refertotheownersmanualforspecicinstallationinstructions,manufacturer’slimitedwarranty,user
responsibility,andpartsandserviceavailability.
• Theinuentwatertothesystemshallincludethefollowingcharacteristics:
o Noorganicsolvents
o Chlorine:<2ppm
o pH:7-8
o Temperature:41~95ºF(5~35ºC)
o Iron:<2ppm
o Turbidity:<1NTU
o Hardness:<1000mg/L
30
• Forpartsandserviceavailability,pleasecontactyourlocaldealerorCoway.
• Thissystemisacceptablefortreatmentofinuentconcentrationsofnomorethan27mg/Lnitrateand3mg/L
nitriteincombinationmeasuredasNandiscertiedfornitrate/nitritereductiononlyforwatersupplieswitha
pressureof2.8kgf/cm2(40psi)orgreater.
• Anitrate/nitritesamplingkitshouldbeusedtomonitorthenitrate/nitritelevelsinyourproductdrinkingwater
atleasteverysixmonths.KitsmaybepurchasedfromyourlocaldealerorCoway.
• Thissystemhasbeentestedforthetreatmentofwatercontainingpentavalentarsenic(alsoknowasAs(V),
As(+5),orarsenate)atconcentrationsof0.050mg/Lorless.Thissystemreducespentavalentarsenic,but
maynotremoveotherformsofarsenic.Thissystemistobeusedonwatersuppliescontainingadetectable
freechlorineresidualatthesysteminletoronwatersuppliesthathavebeendemonstratedtocontainonly
pentavalentarsenic.Treatmentwithchloramines(combinedchlorine)isnotsucienttoensurecomplete
conversionoftrivalentarsenictopentavalentarsenic.PleaseseetheArsenicFactssectionofthisPerformance
DataSheetforfurtherinformation.
• Eciencyratingmeansthepercentageoftheinuentwatertothesystemthatisavailabletotheuserasreverse
osmosistreatedwaterunderoperatingconditionsthatapproximatetypicaldailyusage.
• Theproductwatershouldbetestedevery6monthstoensurethatthecontaminantsarebeingreduced
eectively.PleasecontactyourlocaldealerorCowaytoinitiatethisservice.
• Thisreverseosmosissystemcontainsareplaceabletreatmentcomponents,criticalfortheeectivereductionof
totaldissolvedsolidsandthatproductwatershallbetestedperiodicallytoverifythatthesystemisperforming
properly.Replacementofreverseosmosiscomponentshouldbewithoneofidenticalspecications,asdened
bythemanufacturer,toassurethesameeciencyandcontaminantreductionperformance.
• Theestimatedreplacementtimeoflter,whichisaconsumablepart,isnotanindicationofqualityguarantee
period,butitmeanstheidealtimeoflterreplacement.Accordingly,theestimatedtimeoflterreplacement
maybeshortenedincaseitisusedinanareaofpoorwaterquality.
ModelofFilter Type Usableperiod(months) COSTUS$
WJNF11 NEOSENSEFILTER 6 44.00
WJMF11-50 ROMEMBRANEFILTER 24 140.00
WJIF11
/WJCF11-POST
INNOSENSEFILTER
/POST-CARBONFILTER 18 31.00
WJFF7 FINEFILTER 18 26.00
WJCC-02 CERAMICFILTER 12 11.00
ARSENIC FACTS
Arsenic(abbreviatedAs)isfoundnaturallyinsomewellwater.Arsenicinwaterhasnocolor,tasteorodor.Itmust
bemeasuredbyalabtest.Publicwaterutilitiesmusthavetheirwatertestedforarsenic.Youcangettheresults
fromyourwaterutility.Ifyouhaveyourownwell,youcanhavethewatertested.Thelocalhealthdepartment
orthestateenvironmentalhealthagencycanprovidealistofcertiedlabs.Thecostistypically$15to$30.
InformationaboutarsenicinwatercanbefoundontheInternetattheUSEnvironmentalProtectionAgency
website:
www.epa.gov/safewater/arsenic.html
Therearetwoformsofarsenic:pentavalentarsenic(alsocalledAs(V),As(+5),andarsenate)andtrivalentarsenic
(alsocalledAs(III),As(+3),andarsenite).Inwellwater,arsenicmaybepentavalent,trivalent,oracombinationof
both.Specialsamplingproceduresareneededforalabtodeterminewhattypeandhowmuchofeachtypeof
arsenicisinthewater.Checkwiththelabsinyourareatoseeiftheycanprovidethistypeofservice.
Reverseosmosis(RO)watertreatmentsystemsdonotremovetrivalentarsenicfromwaterverywell.ROsystems
areveryeectiveatremovingpentavalentarsenic.Afreechlorineresidualwillrapidlyconverttrivalentarsenic
topentavalentarsenic.Otherwatertreatmentchemicalssuchasozoneandpotassiumpermanganatewillalso
changetrivalentarsenictopentavalentarsenic.Acombinedchlorineresidual(alsocalledchloramine)maynot
convertallthetrivalentarsenic.Ifyougetyourwaterfromapublicwaterutility,contacttheutilitytondoutiffree
chlorineorcombinedchlorineisusedinthewatersystem.
TheCHP-03ARsystemisdesignedtoremovepentavalentarsenic.Itwillnotconverttrivalentarsenictopentavalent
arsenic.Thesystemwastestedinalab.Underthoseconditions,thesystemreduced0.050mg/Lpentavalent
arsenicto0.010mg/L(ppm)(theUSEPAstandardfordrinkingwater)orless.Theperformanceofthesystemmaybe
dierentatyourinstallation.Havethetreatedwatertestedforarsenictocheckifthesystemisworkingproperly.
TheROcomponentoftheCHP-03ARsystemmustbereplacedevery24monthstoensurethesystemwill
31
StateofCalifornia
DepartmentofPublicHealth
Water Treatment Device
Certicate Number
08 - 1867
DateIssued:June24,2008
Trademark/Model DesignationReplacement Element(s)
MachCHP-03AR WJNF11Neo-SenseFilter
 WJMF11-50ROMembraneFilter
 WJCF11-POSTPost-carbonFilter
 WJFF7FineFilter
 WJCC-02CeramicFilter
Manufacturer:WoongjinCowayCoLTD
Thewatertreatmentdevice(s)listedonthiscerticatehavemetthetestingrequirementspursuanttoSection
116830oftheHealthandSafetyCodeforthefollowinghealthrelatedcontaminants:
Microbiological Contaminants and TurbidityInorganic/Radiological Contaminants
None Arsenic(Pentavalent)1
 Barium
 Cadmium
 Chromium(Hexavalent)
 Chromium(Trivalent)
 Lead
 Nitrate/Nitrite2
 Radium226/228
 Selenium
Organic Contaminants
VOCs
 Alachlor Endrin Simazine
Atrazine Ethylbenzene Styrene
 Benzene EDB 1,1,2,2-Tetrachloroethane
 Carbofuran Haloacetonitriles(HAN) Tetrachloroethylene
 CarbonTetrachloride Bromochloroacetonitrile Toluene
 Chlorobenzene Dibromoacetonitrile 2,4,5-TP(Silvex)
 Chloropicrin Dichloroacetonitrile TribromoaceticAcid
 2,4-D Trichloroacetonitrile 1,2,4-Trichlorobenzene
 DBCP Haloketones(HK) 1,1,1-Trichloroethane
 o-Dichlorobenzene 1,1-Dichloro-2-Propanone 1,1,2-Trichloroethane
 p-Dichlorobenzene 1,1,1-Trichloro-2-Propanone Trichloroethylene
 1,2-Dichloroethane Heptachlor Trihalomethanes(THMs)
 1,1-Dichloroethylene HeptachlorEpoxide Bromodichloromethane
 cis-1,2-Dichloroethylene Hexachlorobutadiene Bromoform
 trans-1,2-Dichloroethylene Hexachlorocyclopentadiene Chloroform
 1,2-Dichloropropane Lindane Chlorodibromomethane
 cis-1,3-Dichloropropylene Methoxychlor Xylenes
 Dinoseb Pentachlorophenol
Rated Service Capacity: 229 galRated Service Flow: 0.07 gpm
Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection
before or after the system.
1Claimsforarsenicreductionshallonlybemadeonwatersuppliesmaintainingdetectableresidualfreechlorineatthe
reverseosmosis(RO)systeminlet.Watersystemsusinganin-linechlorinatorshouldprovideaminimumof1minute
chlorinecontacttimebeforetheROsystem.
2Thissystemisacceptablefortreatmentofinuentconcentrationsofnomorethan27mg/Lnitrateand3mg/Lnitritein
combinationmeasuredasNandiscertiedfornitrate/nitritereductiononlyforwatersupplieswithapressureof280kPa
(40psig)orgreater.Asamplingandanalysistestkitfornitrateisprovidedforcheckingtheperformanceofthissystem.
Frequentanalysisisencouraged.
PERFORMANCE DATA SHEET | CHP-03AR
Others
32
Water Filtration System Performance Data Sheet
Brand: Mach Model: CHP-03AL
ThissystemhasbeentestedandcertiedbytheWaterQualityAssociationaccordingtoNSF/ANSI42,53,and58for
thereductionofthesubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwaterenteringthe
systemwasreducedtoaconcentrationlessthanorequaltothepermissiblelimitforwaterleavingthesystem,as
speciedinNSF/ANSI42,53,and58.
Substance
Max.Allowable
Concentration
(mg/L)
Average
Inuent
(mg/L)
Average
Euent
(mg/L)
Minimum
Percent
Reduction(%)
Average
Percent
Reduction(%)
Arsenic(Pentavalant) 0.010 0.05 0.006 79.1 87.7
Barium 2.0 10 1.4 83.5 86.6
Radium226/228 5pCi/L 25pCi/L 5pCi/L N/A N/A
Cadmium 0.005 0.031 0.002 89.0 92.7
Chromium(Hexavalent) 0.1 0.358 0.023 93.8 95.1
Chromium(Trivalent) 0.1 0.367 0.028 93.8 95.7
Lead 0.010 0.153 0.005 93.6 95.1
Nitrate/Nitrite 10 29.6 4.8 78.5 83.7
Selenium 0.05 0.117 0.003 96.0 97.8
TDS <187.5 741.5 57.8 91.5 92.2
AestheticChlorine
INNOSENSE ≥50% 2.07 0.56 54.53 72.8
POSTCARBON ≥50% 1.96 0.53 55.0 72.8
VOC*
INNOSENSE ≥95%reduction 0.32 0.0077 95.70 97.6
POSTCARBON ≥95%reduction 0.298 0.005 96.0 98.3
Whiletestingwasperformedunderlaboratoryconditions,actualperformancemayvary.
General Operating Information:
RatedCapacity
INNOSENSEFILTER 229gallons(forVOC)
6,103gallons(forAestheticChlorine)
POST-CARBONFILTER 212gallons(forVOC)
1,179gallons(forAestheticChlorine)
Min-Maxoperatingpressure: 20~120psi(1.4~8.4kgf/cm2)
Min-Maxfeedwatertemperature: 41~95ºF(5~35ºC)
RatedServiceFlow 0.07GPM(forVOC)
0.5GPM(forAestheticChlorine)
DailyWaterProductionRate 43.7GPD
ProductEciencyRating 29.5%
ElectricalRequirements: 120Vac/60Hz
• Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfection
beforeorafterthesystem.
• Refertotheownersmanualforspecicinstallationinstructions,manufacturer’slimitedwarranty,user
responsibility,andpartsandserviceavailability.
• Theinuentwatertothesystemshallincludethefollowingcharacteristics:
o Noorganicsolvents
o Chlorine:<2ppm
o pH:7-8
o Temperature:41~95ºF(5~35ºC)
o Iron:<2ppm
o Turbidity:<1NTU
o Hardness:<1000mg/L
33
PERFORMANCE DATA SHEET | CHP-03AL
Others
• Forpartsandserviceavailability,pleasecontactyourlocaldealerorCoway.
• Thissystemisacceptablefortreatmentofinuentconcentrationsofnomorethan27mg/Lnitrateand3mg/L
nitriteincombinationmeasuredasNandiscertiedfornitrate/nitritereductiononlyforwatersupplieswitha
pressureof2.8kgf/cm2(40psi)orgreater.
• Anitrate/nitritesamplingkitshouldbeusedtomonitorthenitrate/nitritelevelsinyourproductdrinkingwater
atleasteverysixmonths.KitsmaybepurchasedfromyourlocaldealerorCoway.
• Thissystemhasbeentestedforthetreatmentofwatercontainingpentavalentarsenic(alsoknowasAs(V),
As(+5),orarsenate)atconcentrationsof0.050mg/Lorless.Thissystemreducespentavalentarsenic,but
maynotremoveotherformsofarsenic.Thissystemistobeusedonwatersuppliescontainingadetectable
freechlorineresidualatthesysteminletoronwatersuppliesthathavebeendemonstratedtocontainonly
pentavalentarsenic.Treatmentwithchloramines(combinedchlorine)isnotsucienttoensurecomplete
conversionoftrivalentarsenictopentavalentarsenic.PleaseseetheArsenicFactssectionofthisPerformance
DataSheetforfurtherinformation.
• Eciencyratingmeansthepercentageoftheinuentwatertothesystemthatisavailabletotheuserasreverse
osmosistreatedwaterunderoperatingconditionsthatapproximatetypicaldailyusage.
• Theproductwatershouldbetestedevery6monthstoensurethatthecontaminantsarebeingreduced
eectively.PleasecontactyourlocaldealerorCowaytoinitiatethisservice.
• Thisreverseosmosissystemcontainsareplaceabletreatmentcomponents,criticalfortheeectivereductionof
totaldissolvedsolidsandthatproductwatershallbetestedperiodicallytoverifythatthesystemisperforming
properly.Replacementofreverseosmosiscomponentshouldbewithoneofidenticalspecications,asdened
bythemanufacturer,toassurethesameeciencyandcontaminantreductionperformance.
• Theestimatedreplacementtimeoflter,whichisaconsumablepart,isnotanindicationofqualityguarantee
period,butitmeanstheidealtimeoflterreplacement.Accordingly,theestimatedtimeoflterreplacement
maybeshortenedincaseitisusedinanareaofpoorwaterquality.
ModelofFilter Type Usableperiod(months) COSTUS$
WJNF11 NEO-SENSEFILTER 6 44.00
WJMF11-30-S ROMEMBRANEFILTER 24 131.00
WJIF11
/WJCF11-POST
INNOSENSEFILTER
/POST-CARBONFILTER 18 31.00
WJFF7 FINEFILTER 18 26.00
WJCC-02 CERAMICFILTER 12 11.00
ARSENIC FACTS
Arsenic(abbreviatedAs)isfoundnaturallyinsomewellwater.Arsenicinwaterhasnocolor,tasteorodor.Itmust
bemeasuredbyalabtest.Publicwaterutilitiesmusthavetheirwatertestedforarsenic.Youcangettheresults
fromyourwaterutility.Ifyouhaveyourownwell,youcanhavethewatertested.Thelocalhealthdepartment
orthestateenvironmentalhealthagencycanprovidealistofcertiedlabs.Thecostistypically$15to$30.
InformationaboutarsenicinwatercanbefoundontheInternetattheUSEnvironmentalProtectionAgency
website:www.epa.gov/safewater/arsenic.html
Therearetwoformsofarsenic:pentavalentarsenic(alsocalledAs(V),As(+5),andarsenate)andtrivalentarsenic
(alsocalledAs(III),As(+3),andarsenite).Inwellwater,arsenicmaybepentavalent,trivalent,oracombinationof
both.Specialsamplingproceduresareneededforalabtodeterminewhattypeandhowmuchofeachtypeof
arsenicisinthewater.Checkwiththelabsinyourareatoseeiftheycanprovidethistypeofservice.
Reverseosmosis(RO)watertreatmentsystemsdonotremovetrivalentarsenicfromwaterverywell.ROsystems
areveryeectiveatremovingpentavalentarsenic.Afreechlorineresidualwillrapidlyconverttrivalentarsenic
topentavalentarsenic.Otherwatertreatmentchemicalssuchasozoneandpotassiumpermanganatewillalso
changetrivalentarsenictopentavalentarsenic.Acombinedchlorineresidual(alsocalledchloramine)maynot
convertallthetrivalentarsenic.Ifyougetyourwaterfromapublicwaterutility,contacttheutilitytondoutiffree
chlorineorcombinedchlorineisusedinthewatersystem.
TheCHP-03ALsystemisdesignedtoremovepentavalentarsenic.Itwillnotconverttrivalentarsenictopentavalent
arsenic.Thesystemwastestedinalab.Underthoseconditions,thesystemreduced0.050mg/Lpentavalent
arsenicto0.010mg/L(ppm)(theUSEPAstandardfordrinkingwater)orless.Theperformanceofthesystemmaybe
dierentatyourinstallation.Havethetreatedwatertestedforarsenictocheckifthesystemisworkingproperly.
TheROcomponentoftheCHP-03ALsystemmustbereplacedevery24monthstoensurethesystemwill
continuetoremovepentavalentarsenic.Thecomponentidenticationandlocationswhereyoucanpurchasethe
componentarelistedintheinstallation/operationmanual.
34
StateofCalifornia
DepartmentofPublicHealth
Water Treatment Device
Certicate Number
08 - 1866
DateIssued:June24,2008
Trademark/Model DesignationReplacement Element(s)
MachCHP-03ALWJNF11Neo-SenseFilter
 WJMF11S-30ROMembraneFilter
 WJCF11-POSTPost-carbonFilter
 WJFF7FineFilter
 WJCC-02CeramicFilter
Manufacturer:WoongjinCowayCoLTD
Thewatertreatmentdevice(s)listedonthiscerticatehavemetthetestingrequirementspursuanttoSection
116830oftheHealthandSafetyCodeforthefollowinghealthrelatedcontaminants:
Microbiological Contaminants and TurbidityInorganic/Radiological Contaminants
None Arsenic(Pentavalent)1
 Barium
 Cadmium
 Chromium(Hexavalent)
 Chromium(Trivalent)
Lead
Nitrate/Nitrite2
Radium226/228
 Selenium
Organic Contaminants
VOCs
 Alachlor Endrin Simazine
 Atrazine Ethylbenzene Styrene
 Benzene EDB 1,1,2,2-Tetrachloroethane
 Carbofuran Haloacetonitriles(HAN) Tetrachloroethylene
 CarbonTetrachloride Bromochloroacetonitrile Toluene
 Chlorobenzene Dibromoacetonitrile 2,4,5-TP(Silvex)
 Chloropicrin Dichloroacetonitrile TribromoaceticAcid
 2,4-D Trichloroacetonitrile 1,2,4-Trichlorobenzene
 DBCP Haloketones(HK) 1,1,1-Trichloroethane
 o-Dichlorobenzene 1,1-Dichloro-2-Propanone 1,1,2-Trichloroethane
 p-Dichlorobenzene 1,1,1-Trichloro-2-Propanone Trichloroethylene
 1,2-Dichloroethane Heptachlor Trihalomethanes(THMs)
 1,1-Dichloroethylene HeptachlorEpoxide Bromodichloromethane
 cis-1,2-Dichloroethylene Hexachlorobutadiene Bromoform
 trans-1,2-Dichloroethylene Hexachlorocyclopentadiene Chloroform
 1,2-Dichloropropane Lindane Chlorodibromomethane
 cis-1,3-Dichloropropylene Methoxychlor Xylenes
 Dinoseb Pentachlorophenol
Rated Service Capacity: 229 galRated Service Flow: 0.07 gpm
Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection
before or after the system.
1Claimsforarsenicreductionshallonlybemadeonwatersuppliesmaintainingdetectableresidualfreechlorineatthe
reverseosmosis(RO)systeminlet.Watersystemsusinganin-linechlorinatorshouldprovideaminimumof1minute
chlorinecontacttimebeforetheROsystem.
2Thissystemisacceptablefortreatmentofinuentconcentrationsofnomorethan27mg/Lnitrateand3mg/Lnitritein
combinationmeasuredasNandiscertiedfornitrate/nitritereductiononlyforwatersupplieswithapressureof280kPa
(40psig)orgreater.Asamplingandanalysistestkitfornitrateisprovidedforcheckingtheperformanceofthissystem.
Frequentanalysisisencouraged.
35
PERFORMANCE DATA SHEET | CHP-03AU
Others
Water Filtration System Performance Data Sheet
Brand: Mach Model: CHP-03AU
ThissystemhasbeentestedandcertiedbytheWaterQualityAssociationaccordingtoNSF/ANSI42,and53for
thereductionofthesubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwaterenteringthe
systemwasreducedtoaconcentrationlessthanorequaltothepermissiblelimitforwaterleavingthesystem,as
speciedinNSF/ANSI42and53.
Substance
Max.Allowable
Concentration
(mg/L)
AverageInuent
(mg/L)
AverageEuent
(mg/L)
Minimum
Percent
Reduction(%)
AveragePercent
Reduction(%)
Aesthetic
Chlorine
INNOSENSE ≥50% 2.07 0.56 54.53 72.8
POSTCARBON ≥50% 1.96 0.53 55.0 72.8
VOC*
INNOSENSE ≥95%reduction 0.32 0.0077 95.70 97.6
POSTCARBON ≥95%reduction 0.298 0.005 96.0 98.3
Whiletestingwasperformedunderlaboratoryconditions,actualperformancemayvary.
General Operating Information:
RatedCapacity
INNOSENSEFILTER 229gallons(forVOC)
6,103gallons(forAestheticChlorine)
POST-CARBONFILTER 212gallons(forVOC)
1,179gallons(forAestheticChlorine)
Min-Maxoperatingpressure: 10~120psi(0.7~8.4kgf/cm2)
Min-Maxfeedwatertemperature: 41~95ºF(5~35ºC)
RatedServiceFlow 0.07GPM(forVOC)
0.5GPM(forAestheticChlorine)
ElectricalRequirements: 120Vac/60Hz
• Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfection
beforeorafterthesystem.
• Refertotheownersmanualforspecicinstallationinstructions,manufacturer’slimitedwarranty,user
responsibility,andpartsandserviceavailability.
• Forpartsandserviceavailability,pleasecontactyourlocaldealerorCoway.
ModelofFilter Type Usableperiod(months) COSTUS$
WJNF11 NEOSENSEFILTER 6 44.00
WJIF11
/WJCF11-POST
INNOSENSEFILTER
/POST-CARBONFILTER 18 31.00
WJMF11-UF UFMEMBRANEFILTER 12 63.00
WJCC-02 CERAMICFILTER 12 11.00
36
Chemical Drinkingwaterregulatory
level
1
(MCL/MAC)mg/L
Inuentchallenge
concentration
2
mg/L
Chemicalreduction
percent
Maximumproductwater
concentrationmg/L
alachlor 0.002 0.050 >98 0.001
3
atrazine 0.003 0.100 >97 0.003
3
benzene 0.005 0.081 >99 0.001
3
carbofuran 0.04 0.190 >99 0.001
3
carbontetrachloride 0.005 0.078 98 0.0018
4
chlorobenzene 0.1 0.077 >99 0.001
3
chloropicrin -0.015 99 0.0002
3
2,4-D 0.07 0.110 98 0.0017
4
dibromochloropropane(DBCP) 0.0002 0.052 >99 0.00002
3
o-dichlorobenzene 0.6 0.080 >99 0.001
3
p-dichlorobenzene 0.075 0.040 >98 0.001
3
1,2-dichloroethane 0.005 0.088 95
5
0.0048
5
1,1-dichloroethylene 0.007 0.083 >99 0.001
3
cis-1,2-dichloroethylene 0.07 0.170 >99 0.0005
3
trans-1,2-dichloroethylene 0.1 0.086 >99 0.001
3
1,2-dichloropropane 0.005 0.080 >99 0.001
3
cis-1,3-dichloropropylene -0.079 >99 0.001
3
dinoseb 0.007 0.170 99 0.0002
4
endrin 0.002 0.053 99 0.00059
4
ethylbenzene 0.7 0.088 >99 0.001
3
ethylenedilbromide(EDB) 0.00005 0.044 >99 0.00002
3
haloacetonitriles(HAN)
bromochloroacetonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetoritrile
-
-
-
-
0.022
0.024
0.0096
0.015
98
98
98
98
0.0005
3
0.0006
3
0.0002
3
0.0003
3
haloketones(HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
-
-
0.0072
0.0082
99
96
0.0001
3
0.0003
3
heptachlor(H-34,Heptox) 0.0004 0.08 >99 0.0004
heptachlorepoxide 0.0002 0.0107
6
98 0.0002
6
hexachlorobutadiene -0.044 >98 0.001
3
hexachlorocyclopentadiene 0.05 0.060 >99 0.000002
3
lindane 0.0002 0.055 >99 0.00001
3
methoxychlor 0.04 0.050 >99 0.0001
3
pentachlorophenol 0.001 0.096 >99 0.001
3
simazine 0.004 0.120 >97 0.004
3
styrene 0.1 0.150 >99 0.0005
3
1,1,2,2-tetrachloroethane -0.081 >99 0.001
3
tetrachloroethylene 0.005 0.081 >99 0.001
3
toluene 10.078 >99 0.001
3
2,4,5-TP(silvex) 0.05 0.270 99 0.0016
4
tribromoaceticacid -0.042 >98 0.001
3
1,2,4-trichlorobenzene 0.07 0.160 >99 0.0005
3
1,1,1-trichloroethane 0.2 0.084 95 0.0046
4
1,1,2-trichloroethane 0.005 0.150 >99 0.0005
3
trichloroethylene 0.005 0.180 >99 0.0010
3
trihalomethanes(includes):
chloroform(surrogatechemical)
bromoform
bromodichloromethane
chlorodibromomethane 0.080 0.300 95 0.015
xylenes(total) 10 0.070 >99 0.001
3
1.TheseharmonizedvalueswereagreeduponbyrepresentativesofUSEPAandHealthCanadaforthepurposeofevaluatingproductstotherequirementsofthisStandard.
2.Inuentchallengelevelsareaverageinuentconcentrationsdeterminedinsurrogatequalicationtesting.
3.Maximumproductwaterlevelwasnotobservedbutwassetatthedetectionlimitoftheanalysis.
4.maximumproductwaterlevelissetatavaluedeterminedinsurrogatequalicationtesting.
5.Chemicalreductionpercentandmaximumproductwaterlevelcalculatedatchloroform95%breakthroughpointasdeterminedinsurrogate
qualicationtesting.
6.Thesurrogatetestresultsforheptachlorepoxidedemonstrateda98%reduction.Thesedatawereusedtocalculateanupperoccurrence
concentrationwhichwouldproduceamaximumproductwaterlevelattheMCL.
* VOC Surrogate Claims
WoongjinCoway.,Ltd.
658,Yugu-Ri,YuguEub,Gongju-Si,Choongchungnam-Do,Korea
Tel.:82-41-850-7879Fax.:82-41-841-7816
37
MEMO
PERFORMANCE DATA SHEET | CHP-03AU
Others
38
What This Warranty Covers:
Commencingwiththedateofpurchaseofthe
Productandcontinuingforaperiodofoneyear,
ifmanufacturingdefectsintheProductcausethe
Producttonotoperateproperlyforitsintended
use,thensubjecttotheexclusions,conditions,and
limitationscontainedherein,COWAYatitssole
optionwillrepairorreplacetheProduct.
Decisionsastotheextentofrepairorreplacement
requiredwillbemadesolelybyCOWAY.
TheremedyunderthisWarrantyisavailableonly
forthatportionoftheProductexhibitingdefects
atthetimeofthewarrantyclaim.Thereplacement
ProductaswellasanyremainingoriginalProduct
willbewarrantedonlyfortheoriginaloneyear
warrantyperiod.Thislimitedwarrantyapplies
onlytoProductusedforanapplicationspecied
byCOWAYfortheProductandappliedinstrict
accordancewithCOWAYpublishedspecications
ineectatthetimeofapplication.IFPRODUCTIS
USEDFOROTHERTHANITSINTENDEDPURPOSE,
ITISSOLDASISANDWITHOUTANYEXPRESS
ORIMPLIEDWARRANTIES,INCLUDINGOF
MERCHANTABILITYORFITNESSFORAPARTICULAR
PURPOSE.
What This Warranty Does Not Cover:
ThisWarrantywarrantsthattheProductwillbe
freefrommanufacturingdefectswhichaectthe
abilityoftheProducttooperateforitsintended
use;itisnotawarrantythattheProductwillnever
requirerepairsortoundertakeresponsibilities,
liabilitiesorobligationsotherthanthose
specicallyidentiedintheprecedingsection.
COWAYisnotresponsibleorliableforpersonal
injuryorpropertydamageofanykind,evenif
arisingfromabreachofthisWarranty.
Limitations and Exclusions:
TOTHEEXTENTPERMITTEDBYAPPLICABLELAW,
COWAYDISCLAIMSANYOTHERWARRANTY
EXPRESSORIMPLIED,THANTHATPROVIDED
FORHEREIN.THISWARRANTYISINLIEUOFAND
EXCLUDESALLOTHERWARRANTIES,GUARANTEES,
CONDITIONSANDREPRESENTATIONS,EXPRESS
ORIMPLIED,ORALORWRITTEN,STATUTORYOR
OTHERWISE,INCLUDINGBUTNOTLIMITEDTO
ANYIMPLIEDCONDITIONSORWARRANTIESAS
TOTHEMERCHANTABILITYORFITNESSFORA
PARTICULARPURPOSEOFTHECOWAYPRODUCT.
SOMESTATESDONOTALLOWLIMITATIONSON
HOWLONGANIMPLIEDWARRANTYLASTS,SO
THEABOVELIMITATIONMAYNOTAPPLYTOYOU.
COWAYDOESNOTAUTHORIZEANYPERSON
INCLUDINGITSREPRESENTATIVES,TOMAKEANY
REPRESENTATIONORTOOFFERANYWARRANTY,
CONDITIONORGUARANTYINRESPECTOFTHE
PRODUCTOTHERTHANTHISWARRANTY.THIS
LIMITEDWARRANTYSHALLBETHEOWNER’S
SOLEANDEXCLUSIVEREMEDYAGAINST
COWAYANDCOWAYSHALLNOTBELIABLEFOR
ANYCONSEQUENTIAL,EXEMPLARY,SPECIAL,
INCIDENTALOROTHERDAMAGESINCLUDING,
BUTNOTLIMITEDTO,LOSSOFPROFITS,AND
LOSSOFUSE.INCIDENTAL,CONSEQUENTIAL
ANDEXEMPLARYDAMAGESSHALLNOTBE
RECOVERABLEEVENIFTHEREMEDIESORTHE
ACTIONSPROVIDEDFORINTHISWARRANTYFAIL
OFTHEIRESSENTIALPURPOSE.SOMESTATESDO
NOTALLOWTHEEXCLUSIONORLIMITATIONOF
INCIDENTALORCONSEQUENTIALDAMAGES,SO
THEABOVELIMITATIONOREXCLUSIONMAYNOT
APPLYTOYOU.COWAYSHALLNOTBELIABLE
FORANYDAMAGESWHICHAREBASEDUPON
NEGLIGENCE,BREACHOFWARRANTY,STRICT
LIABILITYORANYOTHERLEGALTHEORYOF
LIABILITYOTHERTHANTHEEXCLUSIVELIABILITY
SETFORTHINTHISWARRANTY
WARRANTY CARD OR WARRANTY LETTER
ONE YEAR LIMITED WARRANTY
WATER FIRTRATION DEVICE CHP-03AR/L/U (“PRODUCT”)
Model:
Serial Number:
Customer Name: (“OWNER”)
Date of Purchase:
39
Limitations on Implied Warranties:
Anyimpliedwarrantyofmerchantabilityor
tnessforaparticularpurposeoruse,shallbe
limitedtothedurationoftheforegoingexpress
writtenwarranty.
Conditions of Warranty:
COWAY’scontinuingliabilityunderthis
Warrantyisconditioneduponthefollowing:
a) Thedefectordamageisnotcaused
byoristheresultof:abnormaluseor
conditions;improperstorage,unauthorized
modicationsorrepair;misuse,neglect,
accident,alteration,improperinstallationor
otheractsthatarenotthefaultofCowayor
themanufactureroftheproductorthatare
notcoveredbythemanufacturer’swarranty;
b) TheProducthasnotbeenaltered,modied
orrepairedwithoutpriorwrittenapprovalof
COWAY;
c) TheOWNERhasnotiedCOWAYinwriting
ofanyfailureoftheProductcoveredbythis
Warrantywithinthirty(30)daysfollowing
suchfailure;
d) Therehasbeennomisuse,abuseor
negligencewithrespecttotheProducton
thepartoftheOWNER.
Waiver:
COWAY’sfailureatanytimetoenforceorrely
uponanyofthetermsorconditionsstated
hereinshallnotbeconstruedtobeawaiverof
itsrightshereunder.
Obtaining Warranty Service and OWNER’S
Duties:
IftheProductfailstooperateforits
intendedpurpose,thennotifyCowayorits
RepresentativeAgencywithin48hoursor
withinthenextbusinessdayafterdiscovery
ofanydefectintheProduct.TheOWNERmust
givewrittennoticetoCOWAYnolaterthan
thirty(30)daysafteradefectisdiscoveredor
shouldbyreasonablediligencehavebeen
discovered.ClaimsunderthisWarrantywill
requireproofofpurchasebytheOWNER.
USA
 Add :WOONGJINCOWAYUSA,INC.
 695SOUTHVERMONT,STE.110(SOUTHTOWER)LOSANGELES,CA90005,USA
Callcenter. :(213)386-9900/(213)480-1600
 Fax. :(213)386-3990
WARRANTY CARD
Others
40
http://www.coway.com MADEINKOREA
1210108
001

Navigation menu