Coway Chp 03Al Users Manual
CHP-03AR to the manual a0189081-81b8-4b16-9547-81113e71c78a
2015-02-05
: Coway Coway-Chp-03Al-Users-Manual-531479 coway-chp-03al-users-manual-531479 coway pdf
Open the PDF directly: View PDF .
Page Count: 42
CHP-03AR/L/U
Water Filtration Device
• Thisproductcannotbeusedifthevoltageisdierentfromthat
mentionedintheratingplate.
• Foryoursafetyandproperuseoftheproduct,pleasereadthis
User’sManualbeforeuse.
• WarrantycardisincludedinthisUser’sManual.
FEATURES
1. Power saving function using the light sensor
Ifyoupressthe"Sleep"button,asitdecreasesthedrivingtimes
ofthemotorandtheheateratnightautomatically,theamountof
thepowerconsumptionisdecreased.
2. Booster pump for boosting the main water
(CHP-03AR)
Itequippedtheboosterpumptoshowtheuniformltering
abilitiesintheregionwiththelowmainwaterpressure.
3. Low water level detecting function
Itdecreasesthepowerconsumptionbystoppingtheworkingof
themotorandtheheaterwhenthewaterlevelinthedtoragetank
isloweredduetothewaterfailure.
4. Front draining system
Itisconvenientasitcandrainthehotwaterfromthefrontside
withoutmovingtheproductwhenyouopenthefrontdrainingdoor.
5. Fine particles ltering system
Itminimizedtheamountoftheneparticlethatcanbeenteredinto
thewatertankbyequppingtheinno-sencelter.
Sleep
Water Level
Sleep
Water Level
Sleep
Water Level
Sleep
Water Level
Booster
Pump
1
DEAR CUSTOMERS
Thankyouforusingour
Coway Water Filtration Device.
PleasereadthisUsers’Manualtouseandmaintaintheproductcorrectly.
Ifyouencounteraproblemwhileusingtheproduct,youmaysolvetheproblemreferringto
theUser’sManual.Asthismanualcontainstheproductwarrantycard,pleasekeepitinasafe
place.Thissystem(CHP-03AR/L/U)conformstoNSF/ANSI42foraestheticchlorinereduction
andNSF/ANSI53forVOCreductionasveriedandsubstantiatedbytestdata.
Thissystem(CHP-03AR/L)conformstoNSF/ANSI58forthereductionofpentavalentarsenic,
barium,cadmium,selenium,radium226/228,trivalentchromium,hexavalentchromium,lead,
nitrate/nitriteasveriedandsubstantiatedbytestdata.
Thissystem(CHP-03AR/L)registeredinCalifornia.
Seeperformancedatasheetforindividualcontaminantsandreductionperformance.
Thissystem(CHP-03AR/L)isacceptablefortreatmentforinuentconcentrationsofnomore
than27mg/Lnitrateand3mg/LnitriteincombinationmeasuredasNandiscertiedfor
nitrate/nitritereductiononlyforwatersupplieswithapressureof280kPa(40psi)orgreater.
CONTENTS
MAINTENANCE
INSTALLATION ..........................19
CLEANING METHOD ....................21
Storagetank..........................21
Gutter................................23
FILTER REPLACEMENT ...................24
FILTER REPLACEMENT METHOD .........25
OTHERS
TROUBLESHOOTING ....................27
SPECIFICATION .........................28
WATER FLOW DIAGRAM .................29
PERFORMANCE DATA SHEET ............30
WARRANTY CARD .......................39
FOR INFORMATION
SAFETY INFORMATION ...................3
Electricitysafety....................... 3
Installationsafety...................... 4
Operationsafety....................... 5
Others................................. 6
PARTS NAME ............................7
WATER FILTRATION PROCESS .............8
HOW TO USE
INSTALLATION PRECAUTIONS ...........12
OPERATION / INDICATION PART . . . . . . . . . 14
HOW TO USE ............................17
Todrinkthecoldwater................17
Todrinkthehotwater ................17
Todrinktheroomwater ..............18
- Please keep the User’s Manual where it can be readily reached or found -
Coway
FEATURES / CONTENTS
2
SAFETY INFORMATION
Electricity safety
Do not pull the power
cord.
Otherwise,electricshockor
remayoccurasaresult.
Do not touch the power
plug with a wet hand.
Otherwise,electricshockor
remayoccurasaresult.
Do not connect and
pull out the power plug
repeatedly.
Otherwise,electricshockor
remayoccurasaresult.
Unplug the product
before repair, inspection,
or parts replacement.
Otherwise,electricshockor
remayoccurasaresult.
Do not use a damaged
power cord or plug, and
loose outlet.
Otherwise,electricshockor
remayoccurasaresult.
Do not carry the unit by
its power cord.
Otherwise,electricshockor
remayoccurasaresult.
Do not forcefully bend the
power cord or put it under
a heavy object to prevent
it from being damaged or
deformed.
Otherwise,electricshockor
remayoccurasaresult.
If the electric outlet is wet,
carefully unplug the unit
and let the electric outlet
completely dry before
subsequent use.
Otherwise,electricshockor
remayoccurasaresult.
Be careful to keep this safety information.
Pleasereadthisinformationtopreventpropertylossandensureyoursafety.
Ifnotobserved,
seriousinjuryor
evendeathcould
occur.
Ifnotobserved,
seriousinjuryor
propertydamage
couldoccur.
Ifnotobserved,slight
injuryorproperty
damagecouldoccur.
Danger Warning Caution
3
Avoid installing the
system in places where
the air is damp, dust is
accumulated, or water
drops.
Otherwise,electricshockor
remayoccurasaresult.
Do not attempt to repair
or modify the power cord
at your discretion.
Otherwise,electricshockor
remayoccurasaresult.
Do not plug into an
outlet that is being used
by several other
appliances. Use an
electrical outlet dedicated.
Otherwise,remayoccuras
aresult.
Do not install the product
on a sloped oor.
Injurytotheuserordamage
totheunitmayresult.
Installation safety
Do not place or use the
Inammable gases, nor
the ammable materials
near the product.
Otherwise,electricshockor
remayoccurasaresult.
Do not install near a
heating device.
Otherwise,remayoccuras
aresult.
Do not press the product
by constraint or impact.
Injurytodamagetotheunit
mayresult.
SAFETY INFORMATION | Electricity safety | Installation safety
For Information
When you don’t use for a
long time, close the main
water supply valve and
unplug.
Otherwise,electricshockor
remayoccurasaresult.
In the case the power cord
is damaged, do not replace
the cord yourself. Call
Coway Service Center to
have it replaced.
Otherwise,electricshockor
remayoccurasaresult.
Remove any dust or water
o in the pin and contacts
of the power plug.
Otherwise,electricshockor
remayoccurasaresult.
The ltration device installation shall
comply with applicable state and local
regulations.
4
SAFETY INFORMATION
To drink the ltered
water, change the lter
according to the lter
replacement cycle.
Ifyouusetheexpiredlter,
thelterperformanceis
lowered.
Do not put the candle, a
light for cigarette on the
products.
Otherwise,remayoccuras
aresult.
When the water is coming
inside of the product or
there is a puddle on the
product, call Service Center
after closing the supplying
valve and unplugging.
Otherwise,electricshockmay
occurasaresult.
Do not allow hot water to
come in contact with the
human body.
Otherwise,burnmayoccurasa
result.
Operation safety
Do not place any
containers with water,
medicine, food, small
metallic objects, or any
ammable material on
the top of the product.
Inthecaseforeignmaterial
getsinsidetheproduct,
electricshock,re,product
damagemayoccurasaresult.
If our product produces a
strange noise or odd smell,
immediately unplug from
the electrical outlet and
call our Service Center.
Otherwise,electricshockor
remayoccurasaresult.
Use after closing the water
tank cover completely
inside of the product.
Thebuckortheforeignbody
canbeentered.
When you don’t use for a
long time, use after draining
the saved water completely
and emptying the newly
room water once again.
Thesavedwatercanbe
polluted.
Ifnotobserved,
seriousinjuryor
evendeathcould
occur.
Ifnotobserved,
seriousinjuryor
propertydamage
couldoccur.
Ifnotobserved,slight
injuryorproperty
damagecouldoccur.
Danger Warning Caution
5
Others
Do not clean by spraying
the water directly or don’t
wipe the product using the
benzene and thinner.
Otherwise,electricshockor
remayoccurasaresult.
Do not use ltered water
for the water exchange of
an aquarium or a shbowl.
Theroomwaterthroughthe
membraneisn’tsuitablefor
thesh’slifeenvironmentas
itremovedtheionicmaterial.
Insomecases,shesmight
evendie.
Clean after unplugging.
Otherwise,electricshockor
remayoccurasaresult.
Do not repair,
disassemble,
or modify.
Otherwise,electricshockor
productdamagemayoccur
asaresult.
After moving the product
or replacing the inno-
sense lter, the black
powder can be remained
in the inner bottom of
the water tank.
Itisquietharmlessasthe
powderoftheactivated
carbonusedinthe
inno-senselterwasowed
outforimprovingthewater
tastes.
Do not use with water
that is microbiologically
unsafe or of unknown
quality without
adequate disinfection
before or after the
system.
Rotate with grasping the
room water extraction
faucet or don’t raise the
product using the faucet.
Otherwiseleakageor
productdamagemayoccur
asaresult.
Danger Warning Caution
SAFETY INFORMATION | Operating safety | Others
For Information
6
PARTS NAME
Front
Rear
Cup-touch lever
Hot water safety button
Front draining door
Jog shuttle
Hot water safety faucet
Indication part
Gutter
Operation part
Cold/Room water
Changeover faucet
Front cover
Top cover
Rear cover
Power cord
Radiator
Outlet(Blue, CHP-03AR/L)
Inlet(Orange)
7
WATER FILTRATION PROCESS
STEP 1, 2 : NEO-SENSE FILTER
STEP 3 : RO MEMBRANE FILTER
STEP 4 : INNO-SENSE FILTER
STEP 5 : CERAMIC FILTER
Thisneo-senselterhasthefunctiontoreduceaestheticchlorine,odor,volatile
organiccompounds(VOC's).
ROmembranelterhasthefunctiontoreducewatercontaminantssuchaspentavalentarsenic,
barium,cadmium,selenium,radium226/228,trivalentchromium,hexavalentchromium,lead,
nitrate/nitrite.
Thisinno-senselterhasthefunctionstoreducesmellinductionmaterialandtoimprovetasteof
water.Italsohasthefunctiontoreduceaestheticchlorine,volatileorganiccompounds(VOC's).
The 5-step water ltering system (CHP-03AR/L)
Thelteristhecoretechnologyoftheltrationsystem.
Ifyoudon’tusequalifyinglterorifyouuseanoldlterthathasexpired,thesystem
performancemaydegrade.
Disposed
WaterOutlet
NEO-SENSE
FILTER
ROMEMBRANE
FILTER
CERAMIC
FILTER
INNO-SENSE
FILTER
CERAMIC
FILTER
PARTS NAME / WATER FILTRATION PROCESS
For Information
Uses of disposed water
- Thedailylifewatershouldbeusedforcleaningtherestroom,thehouse,clothes,or
purposesotherthandrinking.
- Neverusethedailylifewaterforadrinkingwateroracook.
Tips
8
WATER FILTRATION PROCESS
STEP 1, 2 : NEO-SENSE FILTER
STEP 3 : RO MEMBRANE FILTER
STEP 4 : POST-CARBON FILTER
STEP 6 : CERAMIC FILTER
STEP 5 : FINE FILTER
Thisneo-senselterhasthefunctiontoreduceaestheticchlorine,odor,volatile
organiccompounds(VOC's).
ROmembranelterhasthefunctiontoreducewatercontaminantssuchaspentavalentarsenic,
barium,cadmium,selenium,radium226/228,trivalentchromium,hexavalentchromium,lead,
nitrate/nitrite.
Thispost-carbonlterhasthefunctionstoreducesmellinductionmaterialandtoimprovetasteof
water.Italsohasthefunctiontoreduceaestheticchlorine,volatileorganiccompounds(VOC's).
Thisnelterhasthefunctiontoreduceneparticlesinthewater.
The 6-step water ltering system (CHP-03AR/L)
Disposed
WaterOutlet
NEO-SENSE
FILTER
ROMEMBRANE
FILTER
FINE
FILTER
CERAMIC
FILTER
POST-CARBON
FILTER
CERAMIC
FILTER
9
STEP 1, 2 : NEO-SENSE FILTER
STEP 3 : INNO-SENSE FILTER
STEP 4 : UF MEMBRANE FILTER
STEP 5 : CERAMIC FILTER
Thisneo-senselterhasthefunctiontoreduceaestheticchlorine,odor,volatile
organiccompounds(VOC's).
Thisinno-senselterhasthefunctionstoreducesmellinductionmaterialandto
improvetasteofwater.Italsohasthefunctiontoreduceaestheticchlorine,volatile
organiccompounds(VOC's).
The 5-step water ltering system (CHP-03AU)
NEO-SENSE
FILTER
INNO-SENSE
FILTER
CERAMIC
FILTER
UFMEMBRANE
FILTER
CERAMIC
FILTER
WATER FILTRATION PROCESS
For Information
10
WATER FILTRATION PROCESS
STEP 1, 2 : NEO-SENSE FILTER
STEP 3 : POST-CARBON FILTER
STEP 4 : UF MEMBRANE FILTER
STEP 5 : CERAMIC FILTER
Thisneo-senselterhasthefunctiontoreduceaestheticchlorine,odor,volatile
organiccompounds(VOC's).
Thispost-carbonlterhasthefunctionstoreducesmellinductionmaterialandto
improvetasteofwater.Italsohasthefunctiontoreduceaestheticchlorine,volatile
organiccompounds(VOC's).
The 5-step water ltering system (CHP-03AU)
NEO-SENSE
FILTER
POST-CARBON
FILTER
CERAMIC
FILTER
UFMEMBRANE
FILTER
CERAMIC
FILTER
11
INSTALLATION PRECAUTIONS
The summary for the proper installation of the water ltration device
1. Close main water supply valve to separate the faucet.
2. Wind the teon tape on the adaptor and t it to the
pipe.
3. Connect the faucet with the adaptor.
4. Connect 1/4 inch orange tubing with the connector
on the adaptor.
5. Open the feed valve to supply water to the ltration
system.
Do not tum the water pipe.
Shall install the adaptor with connector on the cold water
pipe.
Flush water through each lter at least 5 minutes before
Connection.
WATER FILTRATION PROCESS / INSTALLATION PRECAUTIONS
For Information
12
INSTALLATION PRECAUTIONS
Please check before use!
This product is for 120 V~ 60 Hz only.
Pleaseconnectthepowerplugtoadedicatedgroundedelectrical
outletfor120V~60Hz.Thewaterltrationdeviceworksnormally
onlywhentheelectricityisconnected.
• Openthemainwatersupplyvalve.
Themainwatermustbesuppliedtooperatethewaterltrationdevicenormally.
• Afterinstallingtheproduct
Getridofthesavedwaterabovethefullwaterintheinnerwatertank2timesormoretouse.
• Whentheindicatorintheindicationpartisturnedo
Whentheindicatorintheindicationpartisturnedo,checkifthepowersupplywasstopped
duetothepowerfailureorothercause.
• Regularlylterreplacement
Itisimportanttoreplacethelterregularlytodrinkthepurewater.Ifthelterisoverused
beyonditsservicelife,theperformanceofthewaterltrationdevicedeteriorate,Donotmissthe
lterreplacementcycle.
• Whenyoudidn’tuseforalongtime
Ifyousavedthewaterforalongtimeoryoudidn’tuse,drainthewaterinsideofthewater
ltrationdevicecompletelyandremovethenewlylteredwateronetimetouse.
• Whenyoudon’twanttouseforalongtime
Closethemainwatersupplyvalveandunplug.
• Draininghotwater
Slidethedrainingcoveratthefrontoftheproductoandconnectthedraininghose
(continuousextractionhose)todrainthehotwaterinthehotwatertank.
(Takecarenottoburnyourselfwhendrainingthehotwater.)
Whenyoudon’tuseforalongtime,closethemainwatersupplyvalveandunplug.
Tips
13
INSTALLATION PRECAUTIONS / OPERATION/INDICATION PART
How to Use
OPERATION / INDICATION PART
Indication part/Operation part
Indicationpart Operationpart
Power
cut
Water
level
Coldwaterfunctionindicator
Waterlevelindicator
ColdwatertemperatureindicatorSleepmodeindicator
Hotwaterfunction
indicator
Hotwater
temperatureindicator
1
4 6
5
23
1
Hot water function
indicator
Whenyouselecthotwater
mode,theindicatoristurned
on.
3
Water level indicator
Theindicatorislightened
accordingtothewaterlevel
ofthestoragetank.
Ifyouconnectthewater
ltrationdevice,oneblankis
lightenedbasically.
5
Cold water function
indicator
Whenyouselectcoldwater
function,theindicatoris
turnedon.
6
Cold water
temperature indicator
Theindicatoristurnedonaccording
tothecoldwatertemperature.As
manyindicatorsareturnedon,the
coldwaterbecomescoldmoreand
more.
4
Sleep mode indicator
Whenyouselectsleepmode,the
indicatoristurnedon.
2
Hot water temperature
indicator
Theindicatoristurnedonaccording
tothehotwatertemperature.As
manyindicatorsareturnedon,the
hotwaterbecomeshotmoreand
more.
14
OPERATION / INDICATION PART
Operation part
Cold water function
selection button
Whenyouwanttoselect/
deselectcoldwater
function,useit.
1 Hot water function
selection button
Whenyouwantto
select/deselectHot
waterfunction,useit.
2
Sleep mode
selection button
Whenyouwishtoselect/
deselectsleepmode,
useit.
3 Light sensor
Itisthesensorsensing
thelightaroundthe
product.
4
▶
Power
cut
Water
level
Sleepmode
selectionbutton
Hotwaterfunction
selectionbutton
Lightsensor
Coldwaterfunction
selectionbutton
1
2
3
4
15
OPERATION/INDICATION PART
How to Use
To use the cold water function
Pressthecoldwaterfunctionselectionbuttonand
checkifcoldwatermodeindicatorintheindication
partisturnedon.Ifyouwanttoturnothecoldwater
mode,presstheselectionbuttonforseveralseconds.
Youcandrinkthecoldwaterwhenyouturnonthe
coldwaterfunctionandabout1hourispassed.
To use the hot water function
Pressthehotwaterfunctionselectionbutton,checkif
thehotwaterfunctionindicatorintheindicationpartis
turnedon.Ifyouwanttoturnothehotwatermode,
pleasepresstheselectionbuttonforseveralseconds.
Youcandrinkthehotwaterwhenyouturnonhot
waterfunctionand30minutesispassed.
To use the sleep mode
Whenyoupressthesleepmodeselectionbutton,as
thesleepmodeindicatoristurnedonandthenumber
ofthemotordrivingisdecreasedatnight,thepower
consumptionisdecreased.
Whenthesleepmodeisoperated,thecoldwater
becomelesscool.
16
HOW TO USE
To drink the hot water
Press the hot water selection button and check the lightening status in the
hot water function indicator.
Press the cold water selection button and check the lightening status in the
cold water function indicator.
Turnthejogshuttletotheleftinthecoldwater/room
waterchangeoverfaucetandpushthecup-touchlever.
Pressthehotwatersafetybuttonandpushthe
cup-touchlever.
▶
▶
Hotwater
safety
button
(PUSH)
▶
Ifthecoldwaterdoesn’tcomefromthewaterltrationdevice,checkifthecoldwater
modeindicatorintheindicationpartisturnedon(SeeP.16).
Tips
Ifthehotwaterdoesn’tcomefromthewaterltrationdevice,checkifthehotwater
modeindicatorintheindicationpartisturnedon(SeeP.16).
Tips
To drink the cold water
17
To drink the room water
Turnthejogshuttletotherightinthecold
water/roomwaterchangeoverfaucetandpush
thecup-touchlever.
▶
HOW TO USE | To drink the cold water | To drink the hot water | To drink the room water
How to Use
18
INSTALLATION
Follow the instruction for installation
Mainwater
supplyvalve 2coolingstopper
120V~60HzOnly
Inlettubing(Orange)
Outlettubing
(Blue,CHP-03AR/L)
Connecttheorangecolorinlettubing 1tothe
tapwatersupplyingpipe.Connectingtheoutlet
tubing 2.
1
2
19
Be cautious!
Water ltration device installation place 1
Pleaseinstallthewaterltrationsystemnotataroughplace,adamp
place,aplacewheretheunitisexposedtothedirectsunlight,aplace
wheredustispresent,oraplacethatthewaterdrops.
Water ltration device installation place 2
Pleaseinstallattheplacewhereitis10cmormoreofromthewall
andthebottomisatandrm.
After installing the water ltration system
Getridofthelteredwaterabovethefulledwater2timesormore
necessarilyafterinstalling.
Cold water plumbing
Pleaseconnecttothecoldwaterpipenecessarily.
(Ifyouconnecttothewarmwaterpipe,theltercanbedamaged.)
Movement and installation
Whenthepositionismoved,connectthepowercordwhen30minutes
passesafterinstalling.
Tomaintainoptimalproductperformance,consultaCowayengineerforthedetailed
installationmethods.
Theremaybesomewaterremaininginsideofthelterwhichwasusedtotestthe
productduringinspectionprocessatthefactory.
Pleasefeelateasyanduseasitisn’ttheusedproduct.
Don’treusethemainwatersupplyvalveandhosethatwaspreviouslyusedwhen
youinstalltheproduct.
Tips
Afte r 3 0
minu t es
Hot water X
INSTALLATION
Maintenance
20
CLEANINGMETHOD
Storage tank
3. Open the upper cover of the product and open the storage tank cover.
1. Turn o by pressing cold water/hot water mode
selection button in the front of the product for
2~3 seconds or more and unplug the power
cord. Close the main water supply valve.
2. Drain the water inside of the water ltration device completely
using the draining hose and the cold water/room water changeover faucet.
Pleasedrainthewaterinthecoldwater/roomwatertank
fromthecoldwater/roomwaterextractionfaucetanddrain
thewaterinthehotwatertankfromthefrontdrainhole.
(SeeP.13forthehotwaterdrainingmethod)
21
CLEANING METHOD | Storage tank
Maintenance
6. Use the storage tank after cleaning it with the taken water, draining
completely using the draining hose, and emptying the newly ltered water
one time or more.
5. Please wipe the surface of the storage tank with
soft clothes.
4. Shake and clean a ceramic lter in the taken water by rotating and
separating it from the cold water/room water separation membrane
.
7. Close the storage tank cover after rotating and equipping the ceramic lter
in the cold water/room water separation membrane.
22
CLEANING METHOD
8.
Open the main water supply valve after closing
the upper cover and plugging the power cord.
Please operate the water ltration device
again by pressing cold water/hot water mode
selection button in the front of the product after
checking if the water is coming from the cold
water/room water extraction faucet and the hot
water extraction faucet.
Gutter
1. Gutter separation method
2. Gutter assembling method
Ifyoupullthefrontpartofthegutter,itisseparated
easily.
Youjustpushthehookofthegutterslightlyafter
stickingtotheproduct.
Closethestoragetankcovercompletely.
Awormoraforeignbodycanbeentered.
Whenyoucleanthestoragetank,don’tusethemedicineorthe
detergent.
Ifyoudon’tcleanthemedicineorthedetergentcleanly,itcanbe
harmfultothebody.
- Keepthesurroundingscleanlyandcleanthestoragetankonce
pertwomonths.
Tips
23
CLEANING METHOD | Gutter / FILTER REPLACEMENT
Maintenance
FILTER REPLACEMENT
Filter
Thelifeofthewaterltrationsystemisthelter.Itisn’tthelegitimated
lteroryouusetoolongevenifitisthelegitimatedlter,thelter
performancecanbelowered.
Pleasechangetothelegitimatedlteraccordingtothereplacementcycle.
Filter replacement cycle
Ifthelterisnotregularlyreplaced,itmaydegradethewaterqualityfrom
theproduct.Thelterreplacementcycledependingonthemainwater
qualitycanbeshortenedraterthantheexpectedreplacementcycle.
Theperiodforthelterexchangeismadebasedon10Luseinadayfor
houseuse(4peoplebased)and20Luseforbusiness.
CHP-03AR
Part No. Names of Filter Usable Period
WJNF11 Neo-senselter 6months
WJMF11-50 ROMembranelter(CHP-03AR) 24months
WJMF11-30-S ROMembranelter(CHP-03AL) 24months
WJIF11
/WJCF11-POST
Inno-senselter
/Post-carbonlter 18months
WJFF7 Finelter 18months
WJCC-02 Ceramiclter 12months
CHP-03AU
Part No. Names of Filter Usable Period
WJNF11 Neo-senselter 6months
WJIF11
/WJCF11-POST
Inno-senselter
/Post-carbonlter 18months
WJMF11-UF Ufmembranelter 12months
WJCC-02 Ceramiclter 12months
About lter replacement cycle
Thelterreplacementcycledescribedaboveisnotthelterquality
warrantyperiodbuttheexpectedcycle(life)thattheltershowsitsoriginal
performance.
Therefore,thelterreplacementcyclemaybereducedfortheareawiththe
poorwaterqualityormoreapplication.
24
FILTER REPLACEMENT METHOD
2. Remove the gutter, and separate the front cover by pressing down, and
unplug and separate all the cables connected completely.
(If the water in the storage tank remains, close the cold water/room water
changeover faucet using the stopper inside of the upper cover
and separate the front cover.)
1. Close the main water supply valve after unplugging the power cord, and
drain the water inside of the water ltration device (See P.21).
1
2
3
4
5
25
FILTER REPLACEMENT METHOD
Maintenance
3. After separating the tting connected to the lter trying to replace, please
replace the lter. (Separate the tting using the proper tool.)
4. After connecting all the separated cables, t a groove in the front cover and
close with pressing it down.
Bychangingthelterandconnectingthettingandthehoseprecisely,checkthat
thereisnoleakageanddraintherstlteredwaternecessarily.
Tips
Pleasebesuretousethenewlteraftercleansing.
- Neo-senselter:PleaseassembleaftercleansingwithNeo-senselterforabout
30seconds.
- Postcarbon/Fine/Inno-sense/Membranelter(RO):
PleaseassembleaftercleansingwiththemainwaterpassedNeo-senselterfor
about3minutes.
Tips
26
TROUBLESHOOTING
Thewaterltrationdevicemayoperateabnormallyduetominorcausesnotbecauseofthe
productmalfunctionbutbecauseofthefactthattheuserisnotfamiliarwiththeproductuse.
Insuchacase,problemscanbesolvedeasilyevenwithoutthehelpfromtheServiceCenterby
checkingthefollowingitems.Ifyoucan’tsolvetheproblemaftercheckingthefollowingitems,
pleasecalltheServiceCenter.
Symptom Check Measures to take
Thewatertastes
weird.
• Didyoucleanthestoragetank? Cleanthestoragetank.
• Youdidn’tusethewaterltrationdevice
foralongtime.
Getridofthesavedwaterandcleanthe
storagetank.
• Isn’titabouttimetochangethelter? Requestthelterreplacement.
Thewaterdoesn’t
come.
• Isthewatersupplycutorisn’tthewater
supplyvalveclosed? Openthemainwatersupplyvalve.
• Didyoumissthelterreplacementtimes? Requestthelterreplacement.
Thewateris
owingslower.
• Isn’titabouttimetochangethelter? Requestthelterreplacement.
• Isthepowerconnected? Checkifthepowercordplugin120V~60
Hzoutlet.
• Didn’tyouclosethemainwatersupply
valve? Openthemainwatersupplyvalve.
• Didn’tthetemperatureofthemainwater
dropsuddenly?
Ifthewatertemperatureislowered,the
wateramountisdecreased.
Thecoldwater
doesn’tcome.
• Wasthecoldwatermodeindicator
lightened?
Pleasepressthecoldwatermodeselection
button.
• Didn’tyouclosethemainwatersupply
valve?
Ifitisthelowwaterleveltoprotectthe
electricmotor,thecoolingfunctiondoesn’t
operate.Openthemainwatersupplyvalve.
• Isn’tthebacksideofthewaterltration
deviceandthewalltooclose?
Pleasekeepthedistancebetweentheback
ofthewaterltrationdeviceandthewallto
10cmormore.
Alloperationwas
stoppedsuddenly
whendriving.
• Isthemainwaterbeingsuppliedactively? Checkthemainwatersupplyvalve.
• Isthepowerconnected? Checkifthepowercordplugin120V~60
Hzoutlet.
• Isn’twateroverowingorleaking? RequestA/S.
27
SPECIFICATION
Product Water Filtration Device
Model CHP-03AR CHP-03AL CHP-03AU
FiltrationMethod RO(ReverseOsmosis) UF
PowerSupply 120V~60Hz
Tank
Capacity
RoomWater 6.59L
ColdWater 3.61L
HotWater 1.2L
Total 11.4L
Dimension 344mm(W)×540mm(D)×525mm(H)
WorkingTemperature 5°C-35°C
ProductionRate 190L/d(25°C,414kPa) 113L/d(25°C,138kPa) 1500L/d(25°C,108kPa)
WorkingPressure 69kPa–827kPa 138kPa–827kPa 69kPa–827kPa
NetWeight 22.3kg 19.8kg 19.8kg
• Thewateramountcanbedierentiatedaccordingtothewaterpressureandthewater
temperature.
• Thewatertankcapacityistheamountbythesizeandcanbedierentfromtheextraction
capacity.
• Withoutanypriornotice,allorpartsoftheproductaresubjecttochangeforthepurposeof
improvingtheperformanceoftheproduct.
• Refertoperformancedatasheetforindividualcontaminants,reductionperformanceandgeneral
operatinginformation.
TROUBLESHOOTING / SPECIFICATION
Others
28
WATER FLOW DIAGRAM
CHP-03AR
CHP-03AL
CHP-03AU
• Apostcarbonltermaybeinstalledinsteadofaninno-senselter.
Fortheprecisespecicationsofyourproduct,refertothedataplateontheproduct.
29
WATER FLOW DIAGRAM / PERFORMANCE DATA SHEET | CHP-03AR
Others
Water Filtration System Performance Data Sheet
Brand: Mach Model: CHP-03AR
ThissystemhasbeentestedandcertiedbytheWaterQualityAssociationaccordingtoNSF/ANSI42,53,and58for
thereductionofthesubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwaterenteringthe
systemwasreducedtoaconcentrationlessthanorequaltothepermissiblelimitforwaterleavingthesystem,as
speciedinNSF/ANSI42,53,and58.
Substance
Max.Allowable
Concentration
(mg/L)
Average
Inuent
(mg/L)
Average
Euent
(mg/L)
Minimum
Percent
Reduction(%)
Average
Percent
Reduction(%)
Arsenic(Pentavalant) 0.010 0.05 0.006 79.1 87.7
Barium 2.0 10 1.4 83.5 86.6
Radium226/228 5pCi/L 25pCi/L 5pCi/L N/A N/A
Cadmium 0.005 0.031 0.002 89.0 92.7
Chromium(Hexavalent) 0.1 0.358 0.023 93.8 95.1
Chromium(Trivalent) 0.1 0.367 0.028 93.8 95.7
Lead 0.010 0.153 0.005 93.6 95.1
Nitrate/Nitrite 10 29.6 4.8 78.5 83.7
Selenium 0.05 0.117 0.003 96.0 97.8
TDS <187.5 741.5 27.7 95.7 96.3
AestheticChlorine
INNOSENSE ≥50% 2.07 0.56 54.53 72.8
POSTCARBON ≥50% 1.96 0.53 55.0 72.8
VOC*
INNOSENSE ≥95%reduction 0.32 0.0077 95.70 97.6
POSTCARBON ≥95%reduction 0.298 0.005 96.0 98.3
Whiletestingwasperformedunderlaboratoryconditions,actualperformancemayvary.
General Operating Information:
RatedCapacity
INNOSENSEFILTER 229gallons(forVOC)
6,103gallons(forAestheticChlorine)
POST-CARBONFILTER 212gallons(forVOC)
1,179gallons(forAestheticChlorine)
Min-Maxoperatingpressure: 10~120psi(0.7~8.4kgf/cm2)
Min-Maxfeedwatertemperature: 41~95ºF(5~35ºC)
RatedServiceFlow 0.07GPM(forVOC)
0.5GPM(forAestheticChlorine)
DailyWaterProductionRate 82.3GPD
ProductEciencyRating 39.2%
ElectricalRequirements: 120Vac/60Hz
• Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfection
beforeorafterthesystem.
• Refertotheownersmanualforspecicinstallationinstructions,manufacturer’slimitedwarranty,user
responsibility,andpartsandserviceavailability.
• Theinuentwatertothesystemshallincludethefollowingcharacteristics:
o Noorganicsolvents
o Chlorine:<2ppm
o pH:7-8
o Temperature:41~95ºF(5~35ºC)
o Iron:<2ppm
o Turbidity:<1NTU
o Hardness:<1000mg/L
30
• Forpartsandserviceavailability,pleasecontactyourlocaldealerorCoway.
• Thissystemisacceptablefortreatmentofinuentconcentrationsofnomorethan27mg/Lnitrateand3mg/L
nitriteincombinationmeasuredasNandiscertiedfornitrate/nitritereductiononlyforwatersupplieswitha
pressureof2.8kgf/cm2(40psi)orgreater.
• Anitrate/nitritesamplingkitshouldbeusedtomonitorthenitrate/nitritelevelsinyourproductdrinkingwater
atleasteverysixmonths.KitsmaybepurchasedfromyourlocaldealerorCoway.
• Thissystemhasbeentestedforthetreatmentofwatercontainingpentavalentarsenic(alsoknowasAs(V),
As(+5),orarsenate)atconcentrationsof0.050mg/Lorless.Thissystemreducespentavalentarsenic,but
maynotremoveotherformsofarsenic.Thissystemistobeusedonwatersuppliescontainingadetectable
freechlorineresidualatthesysteminletoronwatersuppliesthathavebeendemonstratedtocontainonly
pentavalentarsenic.Treatmentwithchloramines(combinedchlorine)isnotsucienttoensurecomplete
conversionoftrivalentarsenictopentavalentarsenic.PleaseseetheArsenicFactssectionofthisPerformance
DataSheetforfurtherinformation.
• Eciencyratingmeansthepercentageoftheinuentwatertothesystemthatisavailabletotheuserasreverse
osmosistreatedwaterunderoperatingconditionsthatapproximatetypicaldailyusage.
• Theproductwatershouldbetestedevery6monthstoensurethatthecontaminantsarebeingreduced
eectively.PleasecontactyourlocaldealerorCowaytoinitiatethisservice.
• Thisreverseosmosissystemcontainsareplaceabletreatmentcomponents,criticalfortheeectivereductionof
totaldissolvedsolidsandthatproductwatershallbetestedperiodicallytoverifythatthesystemisperforming
properly.Replacementofreverseosmosiscomponentshouldbewithoneofidenticalspecications,asdened
bythemanufacturer,toassurethesameeciencyandcontaminantreductionperformance.
• Theestimatedreplacementtimeoflter,whichisaconsumablepart,isnotanindicationofqualityguarantee
period,butitmeanstheidealtimeoflterreplacement.Accordingly,theestimatedtimeoflterreplacement
maybeshortenedincaseitisusedinanareaofpoorwaterquality.
ModelofFilter Type Usableperiod(months) COSTUS$
WJNF11 NEOSENSEFILTER 6 44.00
WJMF11-50 ROMEMBRANEFILTER 24 140.00
WJIF11
/WJCF11-POST
INNOSENSEFILTER
/POST-CARBONFILTER 18 31.00
WJFF7 FINEFILTER 18 26.00
WJCC-02 CERAMICFILTER 12 11.00
ARSENIC FACTS
Arsenic(abbreviatedAs)isfoundnaturallyinsomewellwater.Arsenicinwaterhasnocolor,tasteorodor.Itmust
bemeasuredbyalabtest.Publicwaterutilitiesmusthavetheirwatertestedforarsenic.Youcangettheresults
fromyourwaterutility.Ifyouhaveyourownwell,youcanhavethewatertested.Thelocalhealthdepartment
orthestateenvironmentalhealthagencycanprovidealistofcertiedlabs.Thecostistypically$15to$30.
InformationaboutarsenicinwatercanbefoundontheInternetattheUSEnvironmentalProtectionAgency
website:
www.epa.gov/safewater/arsenic.html
Therearetwoformsofarsenic:pentavalentarsenic(alsocalledAs(V),As(+5),andarsenate)andtrivalentarsenic
(alsocalledAs(III),As(+3),andarsenite).Inwellwater,arsenicmaybepentavalent,trivalent,oracombinationof
both.Specialsamplingproceduresareneededforalabtodeterminewhattypeandhowmuchofeachtypeof
arsenicisinthewater.Checkwiththelabsinyourareatoseeiftheycanprovidethistypeofservice.
Reverseosmosis(RO)watertreatmentsystemsdonotremovetrivalentarsenicfromwaterverywell.ROsystems
areveryeectiveatremovingpentavalentarsenic.Afreechlorineresidualwillrapidlyconverttrivalentarsenic
topentavalentarsenic.Otherwatertreatmentchemicalssuchasozoneandpotassiumpermanganatewillalso
changetrivalentarsenictopentavalentarsenic.Acombinedchlorineresidual(alsocalledchloramine)maynot
convertallthetrivalentarsenic.Ifyougetyourwaterfromapublicwaterutility,contacttheutilitytondoutiffree
chlorineorcombinedchlorineisusedinthewatersystem.
TheCHP-03ARsystemisdesignedtoremovepentavalentarsenic.Itwillnotconverttrivalentarsenictopentavalent
arsenic.Thesystemwastestedinalab.Underthoseconditions,thesystemreduced0.050mg/Lpentavalent
arsenicto0.010mg/L(ppm)(theUSEPAstandardfordrinkingwater)orless.Theperformanceofthesystemmaybe
dierentatyourinstallation.Havethetreatedwatertestedforarsenictocheckifthesystemisworkingproperly.
TheROcomponentoftheCHP-03ARsystemmustbereplacedevery24monthstoensurethesystemwill
31
StateofCalifornia
DepartmentofPublicHealth
Water Treatment Device
Certicate Number
08 - 1867
DateIssued:June24,2008
Trademark/Model DesignationReplacement Element(s)
MachCHP-03AR WJNF11Neo-SenseFilter
WJMF11-50ROMembraneFilter
WJCF11-POSTPost-carbonFilter
WJFF7FineFilter
WJCC-02CeramicFilter
Manufacturer:WoongjinCowayCoLTD
Thewatertreatmentdevice(s)listedonthiscerticatehavemetthetestingrequirementspursuanttoSection
116830oftheHealthandSafetyCodeforthefollowinghealthrelatedcontaminants:
Microbiological Contaminants and TurbidityInorganic/Radiological Contaminants
None Arsenic(Pentavalent)1
Barium
Cadmium
Chromium(Hexavalent)
Chromium(Trivalent)
Lead
Nitrate/Nitrite2
Radium226/228
Selenium
Organic Contaminants
VOCs
Alachlor Endrin Simazine
Atrazine Ethylbenzene Styrene
Benzene EDB 1,1,2,2-Tetrachloroethane
Carbofuran Haloacetonitriles(HAN) Tetrachloroethylene
CarbonTetrachloride Bromochloroacetonitrile Toluene
Chlorobenzene Dibromoacetonitrile 2,4,5-TP(Silvex)
Chloropicrin Dichloroacetonitrile TribromoaceticAcid
2,4-D Trichloroacetonitrile 1,2,4-Trichlorobenzene
DBCP Haloketones(HK) 1,1,1-Trichloroethane
o-Dichlorobenzene 1,1-Dichloro-2-Propanone 1,1,2-Trichloroethane
p-Dichlorobenzene 1,1,1-Trichloro-2-Propanone Trichloroethylene
1,2-Dichloroethane Heptachlor Trihalomethanes(THMs)
1,1-Dichloroethylene HeptachlorEpoxide Bromodichloromethane
cis-1,2-Dichloroethylene Hexachlorobutadiene Bromoform
trans-1,2-Dichloroethylene Hexachlorocyclopentadiene Chloroform
1,2-Dichloropropane Lindane Chlorodibromomethane
cis-1,3-Dichloropropylene Methoxychlor Xylenes
Dinoseb Pentachlorophenol
Rated Service Capacity: 229 galRated Service Flow: 0.07 gpm
Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection
before or after the system.
1Claimsforarsenicreductionshallonlybemadeonwatersuppliesmaintainingdetectableresidualfreechlorineatthe
reverseosmosis(RO)systeminlet.Watersystemsusinganin-linechlorinatorshouldprovideaminimumof1minute
chlorinecontacttimebeforetheROsystem.
2Thissystemisacceptablefortreatmentofinuentconcentrationsofnomorethan27mg/Lnitrateand3mg/Lnitritein
combinationmeasuredasNandiscertiedfornitrate/nitritereductiononlyforwatersupplieswithapressureof280kPa
(40psig)orgreater.Asamplingandanalysistestkitfornitrateisprovidedforcheckingtheperformanceofthissystem.
Frequentanalysisisencouraged.
PERFORMANCE DATA SHEET | CHP-03AR
Others
32
Water Filtration System Performance Data Sheet
Brand: Mach Model: CHP-03AL
ThissystemhasbeentestedandcertiedbytheWaterQualityAssociationaccordingtoNSF/ANSI42,53,and58for
thereductionofthesubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwaterenteringthe
systemwasreducedtoaconcentrationlessthanorequaltothepermissiblelimitforwaterleavingthesystem,as
speciedinNSF/ANSI42,53,and58.
Substance
Max.Allowable
Concentration
(mg/L)
Average
Inuent
(mg/L)
Average
Euent
(mg/L)
Minimum
Percent
Reduction(%)
Average
Percent
Reduction(%)
Arsenic(Pentavalant) 0.010 0.05 0.006 79.1 87.7
Barium 2.0 10 1.4 83.5 86.6
Radium226/228 5pCi/L 25pCi/L 5pCi/L N/A N/A
Cadmium 0.005 0.031 0.002 89.0 92.7
Chromium(Hexavalent) 0.1 0.358 0.023 93.8 95.1
Chromium(Trivalent) 0.1 0.367 0.028 93.8 95.7
Lead 0.010 0.153 0.005 93.6 95.1
Nitrate/Nitrite 10 29.6 4.8 78.5 83.7
Selenium 0.05 0.117 0.003 96.0 97.8
TDS <187.5 741.5 57.8 91.5 92.2
AestheticChlorine
INNOSENSE ≥50% 2.07 0.56 54.53 72.8
POSTCARBON ≥50% 1.96 0.53 55.0 72.8
VOC*
INNOSENSE ≥95%reduction 0.32 0.0077 95.70 97.6
POSTCARBON ≥95%reduction 0.298 0.005 96.0 98.3
Whiletestingwasperformedunderlaboratoryconditions,actualperformancemayvary.
General Operating Information:
RatedCapacity
INNOSENSEFILTER 229gallons(forVOC)
6,103gallons(forAestheticChlorine)
POST-CARBONFILTER 212gallons(forVOC)
1,179gallons(forAestheticChlorine)
Min-Maxoperatingpressure: 20~120psi(1.4~8.4kgf/cm2)
Min-Maxfeedwatertemperature: 41~95ºF(5~35ºC)
RatedServiceFlow 0.07GPM(forVOC)
0.5GPM(forAestheticChlorine)
DailyWaterProductionRate 43.7GPD
ProductEciencyRating 29.5%
ElectricalRequirements: 120Vac/60Hz
• Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfection
beforeorafterthesystem.
• Refertotheownersmanualforspecicinstallationinstructions,manufacturer’slimitedwarranty,user
responsibility,andpartsandserviceavailability.
• Theinuentwatertothesystemshallincludethefollowingcharacteristics:
o Noorganicsolvents
o Chlorine:<2ppm
o pH:7-8
o Temperature:41~95ºF(5~35ºC)
o Iron:<2ppm
o Turbidity:<1NTU
o Hardness:<1000mg/L
33
PERFORMANCE DATA SHEET | CHP-03AL
Others
• Forpartsandserviceavailability,pleasecontactyourlocaldealerorCoway.
• Thissystemisacceptablefortreatmentofinuentconcentrationsofnomorethan27mg/Lnitrateand3mg/L
nitriteincombinationmeasuredasNandiscertiedfornitrate/nitritereductiononlyforwatersupplieswitha
pressureof2.8kgf/cm2(40psi)orgreater.
• Anitrate/nitritesamplingkitshouldbeusedtomonitorthenitrate/nitritelevelsinyourproductdrinkingwater
atleasteverysixmonths.KitsmaybepurchasedfromyourlocaldealerorCoway.
• Thissystemhasbeentestedforthetreatmentofwatercontainingpentavalentarsenic(alsoknowasAs(V),
As(+5),orarsenate)atconcentrationsof0.050mg/Lorless.Thissystemreducespentavalentarsenic,but
maynotremoveotherformsofarsenic.Thissystemistobeusedonwatersuppliescontainingadetectable
freechlorineresidualatthesysteminletoronwatersuppliesthathavebeendemonstratedtocontainonly
pentavalentarsenic.Treatmentwithchloramines(combinedchlorine)isnotsucienttoensurecomplete
conversionoftrivalentarsenictopentavalentarsenic.PleaseseetheArsenicFactssectionofthisPerformance
DataSheetforfurtherinformation.
• Eciencyratingmeansthepercentageoftheinuentwatertothesystemthatisavailabletotheuserasreverse
osmosistreatedwaterunderoperatingconditionsthatapproximatetypicaldailyusage.
• Theproductwatershouldbetestedevery6monthstoensurethatthecontaminantsarebeingreduced
eectively.PleasecontactyourlocaldealerorCowaytoinitiatethisservice.
• Thisreverseosmosissystemcontainsareplaceabletreatmentcomponents,criticalfortheeectivereductionof
totaldissolvedsolidsandthatproductwatershallbetestedperiodicallytoverifythatthesystemisperforming
properly.Replacementofreverseosmosiscomponentshouldbewithoneofidenticalspecications,asdened
bythemanufacturer,toassurethesameeciencyandcontaminantreductionperformance.
• Theestimatedreplacementtimeoflter,whichisaconsumablepart,isnotanindicationofqualityguarantee
period,butitmeanstheidealtimeoflterreplacement.Accordingly,theestimatedtimeoflterreplacement
maybeshortenedincaseitisusedinanareaofpoorwaterquality.
ModelofFilter Type Usableperiod(months) COSTUS$
WJNF11 NEO-SENSEFILTER 6 44.00
WJMF11-30-S ROMEMBRANEFILTER 24 131.00
WJIF11
/WJCF11-POST
INNOSENSEFILTER
/POST-CARBONFILTER 18 31.00
WJFF7 FINEFILTER 18 26.00
WJCC-02 CERAMICFILTER 12 11.00
ARSENIC FACTS
Arsenic(abbreviatedAs)isfoundnaturallyinsomewellwater.Arsenicinwaterhasnocolor,tasteorodor.Itmust
bemeasuredbyalabtest.Publicwaterutilitiesmusthavetheirwatertestedforarsenic.Youcangettheresults
fromyourwaterutility.Ifyouhaveyourownwell,youcanhavethewatertested.Thelocalhealthdepartment
orthestateenvironmentalhealthagencycanprovidealistofcertiedlabs.Thecostistypically$15to$30.
InformationaboutarsenicinwatercanbefoundontheInternetattheUSEnvironmentalProtectionAgency
website:www.epa.gov/safewater/arsenic.html
Therearetwoformsofarsenic:pentavalentarsenic(alsocalledAs(V),As(+5),andarsenate)andtrivalentarsenic
(alsocalledAs(III),As(+3),andarsenite).Inwellwater,arsenicmaybepentavalent,trivalent,oracombinationof
both.Specialsamplingproceduresareneededforalabtodeterminewhattypeandhowmuchofeachtypeof
arsenicisinthewater.Checkwiththelabsinyourareatoseeiftheycanprovidethistypeofservice.
Reverseosmosis(RO)watertreatmentsystemsdonotremovetrivalentarsenicfromwaterverywell.ROsystems
areveryeectiveatremovingpentavalentarsenic.Afreechlorineresidualwillrapidlyconverttrivalentarsenic
topentavalentarsenic.Otherwatertreatmentchemicalssuchasozoneandpotassiumpermanganatewillalso
changetrivalentarsenictopentavalentarsenic.Acombinedchlorineresidual(alsocalledchloramine)maynot
convertallthetrivalentarsenic.Ifyougetyourwaterfromapublicwaterutility,contacttheutilitytondoutiffree
chlorineorcombinedchlorineisusedinthewatersystem.
TheCHP-03ALsystemisdesignedtoremovepentavalentarsenic.Itwillnotconverttrivalentarsenictopentavalent
arsenic.Thesystemwastestedinalab.Underthoseconditions,thesystemreduced0.050mg/Lpentavalent
arsenicto0.010mg/L(ppm)(theUSEPAstandardfordrinkingwater)orless.Theperformanceofthesystemmaybe
dierentatyourinstallation.Havethetreatedwatertestedforarsenictocheckifthesystemisworkingproperly.
TheROcomponentoftheCHP-03ALsystemmustbereplacedevery24monthstoensurethesystemwill
continuetoremovepentavalentarsenic.Thecomponentidenticationandlocationswhereyoucanpurchasethe
componentarelistedintheinstallation/operationmanual.
34
StateofCalifornia
DepartmentofPublicHealth
Water Treatment Device
Certicate Number
08 - 1866
DateIssued:June24,2008
Trademark/Model DesignationReplacement Element(s)
MachCHP-03ALWJNF11Neo-SenseFilter
WJMF11S-30ROMembraneFilter
WJCF11-POSTPost-carbonFilter
WJFF7FineFilter
WJCC-02CeramicFilter
Manufacturer:WoongjinCowayCoLTD
Thewatertreatmentdevice(s)listedonthiscerticatehavemetthetestingrequirementspursuanttoSection
116830oftheHealthandSafetyCodeforthefollowinghealthrelatedcontaminants:
Microbiological Contaminants and TurbidityInorganic/Radiological Contaminants
None Arsenic(Pentavalent)1
Barium
Cadmium
Chromium(Hexavalent)
Chromium(Trivalent)
Lead
Nitrate/Nitrite2
Radium226/228
Selenium
Organic Contaminants
VOCs
Alachlor Endrin Simazine
Atrazine Ethylbenzene Styrene
Benzene EDB 1,1,2,2-Tetrachloroethane
Carbofuran Haloacetonitriles(HAN) Tetrachloroethylene
CarbonTetrachloride Bromochloroacetonitrile Toluene
Chlorobenzene Dibromoacetonitrile 2,4,5-TP(Silvex)
Chloropicrin Dichloroacetonitrile TribromoaceticAcid
2,4-D Trichloroacetonitrile 1,2,4-Trichlorobenzene
DBCP Haloketones(HK) 1,1,1-Trichloroethane
o-Dichlorobenzene 1,1-Dichloro-2-Propanone 1,1,2-Trichloroethane
p-Dichlorobenzene 1,1,1-Trichloro-2-Propanone Trichloroethylene
1,2-Dichloroethane Heptachlor Trihalomethanes(THMs)
1,1-Dichloroethylene HeptachlorEpoxide Bromodichloromethane
cis-1,2-Dichloroethylene Hexachlorobutadiene Bromoform
trans-1,2-Dichloroethylene Hexachlorocyclopentadiene Chloroform
1,2-Dichloropropane Lindane Chlorodibromomethane
cis-1,3-Dichloropropylene Methoxychlor Xylenes
Dinoseb Pentachlorophenol
Rated Service Capacity: 229 galRated Service Flow: 0.07 gpm
Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection
before or after the system.
1Claimsforarsenicreductionshallonlybemadeonwatersuppliesmaintainingdetectableresidualfreechlorineatthe
reverseosmosis(RO)systeminlet.Watersystemsusinganin-linechlorinatorshouldprovideaminimumof1minute
chlorinecontacttimebeforetheROsystem.
2Thissystemisacceptablefortreatmentofinuentconcentrationsofnomorethan27mg/Lnitrateand3mg/Lnitritein
combinationmeasuredasNandiscertiedfornitrate/nitritereductiononlyforwatersupplieswithapressureof280kPa
(40psig)orgreater.Asamplingandanalysistestkitfornitrateisprovidedforcheckingtheperformanceofthissystem.
Frequentanalysisisencouraged.
35
PERFORMANCE DATA SHEET | CHP-03AU
Others
Water Filtration System Performance Data Sheet
Brand: Mach Model: CHP-03AU
ThissystemhasbeentestedandcertiedbytheWaterQualityAssociationaccordingtoNSF/ANSI42,and53for
thereductionofthesubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwaterenteringthe
systemwasreducedtoaconcentrationlessthanorequaltothepermissiblelimitforwaterleavingthesystem,as
speciedinNSF/ANSI42and53.
Substance
Max.Allowable
Concentration
(mg/L)
AverageInuent
(mg/L)
AverageEuent
(mg/L)
Minimum
Percent
Reduction(%)
AveragePercent
Reduction(%)
Aesthetic
Chlorine
INNOSENSE ≥50% 2.07 0.56 54.53 72.8
POSTCARBON ≥50% 1.96 0.53 55.0 72.8
VOC*
INNOSENSE ≥95%reduction 0.32 0.0077 95.70 97.6
POSTCARBON ≥95%reduction 0.298 0.005 96.0 98.3
Whiletestingwasperformedunderlaboratoryconditions,actualperformancemayvary.
General Operating Information:
RatedCapacity
INNOSENSEFILTER 229gallons(forVOC)
6,103gallons(forAestheticChlorine)
POST-CARBONFILTER 212gallons(forVOC)
1,179gallons(forAestheticChlorine)
Min-Maxoperatingpressure: 10~120psi(0.7~8.4kgf/cm2)
Min-Maxfeedwatertemperature: 41~95ºF(5~35ºC)
RatedServiceFlow 0.07GPM(forVOC)
0.5GPM(forAestheticChlorine)
ElectricalRequirements: 120Vac/60Hz
• Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfection
beforeorafterthesystem.
• Refertotheownersmanualforspecicinstallationinstructions,manufacturer’slimitedwarranty,user
responsibility,andpartsandserviceavailability.
• Forpartsandserviceavailability,pleasecontactyourlocaldealerorCoway.
ModelofFilter Type Usableperiod(months) COSTUS$
WJNF11 NEOSENSEFILTER 6 44.00
WJIF11
/WJCF11-POST
INNOSENSEFILTER
/POST-CARBONFILTER 18 31.00
WJMF11-UF UFMEMBRANEFILTER 12 63.00
WJCC-02 CERAMICFILTER 12 11.00
36
Chemical Drinkingwaterregulatory
level
1
(MCL/MAC)mg/L
Inuentchallenge
concentration
2
mg/L
Chemicalreduction
percent
Maximumproductwater
concentrationmg/L
alachlor 0.002 0.050 >98 0.001
3
atrazine 0.003 0.100 >97 0.003
3
benzene 0.005 0.081 >99 0.001
3
carbofuran 0.04 0.190 >99 0.001
3
carbontetrachloride 0.005 0.078 98 0.0018
4
chlorobenzene 0.1 0.077 >99 0.001
3
chloropicrin -0.015 99 0.0002
3
2,4-D 0.07 0.110 98 0.0017
4
dibromochloropropane(DBCP) 0.0002 0.052 >99 0.00002
3
o-dichlorobenzene 0.6 0.080 >99 0.001
3
p-dichlorobenzene 0.075 0.040 >98 0.001
3
1,2-dichloroethane 0.005 0.088 95
5
0.0048
5
1,1-dichloroethylene 0.007 0.083 >99 0.001
3
cis-1,2-dichloroethylene 0.07 0.170 >99 0.0005
3
trans-1,2-dichloroethylene 0.1 0.086 >99 0.001
3
1,2-dichloropropane 0.005 0.080 >99 0.001
3
cis-1,3-dichloropropylene -0.079 >99 0.001
3
dinoseb 0.007 0.170 99 0.0002
4
endrin 0.002 0.053 99 0.00059
4
ethylbenzene 0.7 0.088 >99 0.001
3
ethylenedilbromide(EDB) 0.00005 0.044 >99 0.00002
3
haloacetonitriles(HAN)
bromochloroacetonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetoritrile
-
-
-
-
0.022
0.024
0.0096
0.015
98
98
98
98
0.0005
3
0.0006
3
0.0002
3
0.0003
3
haloketones(HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
-
-
0.0072
0.0082
99
96
0.0001
3
0.0003
3
heptachlor(H-34,Heptox) 0.0004 0.08 >99 0.0004
heptachlorepoxide 0.0002 0.0107
6
98 0.0002
6
hexachlorobutadiene -0.044 >98 0.001
3
hexachlorocyclopentadiene 0.05 0.060 >99 0.000002
3
lindane 0.0002 0.055 >99 0.00001
3
methoxychlor 0.04 0.050 >99 0.0001
3
pentachlorophenol 0.001 0.096 >99 0.001
3
simazine 0.004 0.120 >97 0.004
3
styrene 0.1 0.150 >99 0.0005
3
1,1,2,2-tetrachloroethane -0.081 >99 0.001
3
tetrachloroethylene 0.005 0.081 >99 0.001
3
toluene 10.078 >99 0.001
3
2,4,5-TP(silvex) 0.05 0.270 99 0.0016
4
tribromoaceticacid -0.042 >98 0.001
3
1,2,4-trichlorobenzene 0.07 0.160 >99 0.0005
3
1,1,1-trichloroethane 0.2 0.084 95 0.0046
4
1,1,2-trichloroethane 0.005 0.150 >99 0.0005
3
trichloroethylene 0.005 0.180 >99 0.0010
3
trihalomethanes(includes):
chloroform(surrogatechemical)
bromoform
bromodichloromethane
chlorodibromomethane 0.080 0.300 95 0.015
xylenes(total) 10 0.070 >99 0.001
3
1.TheseharmonizedvalueswereagreeduponbyrepresentativesofUSEPAandHealthCanadaforthepurposeofevaluatingproductstotherequirementsofthisStandard.
2.Inuentchallengelevelsareaverageinuentconcentrationsdeterminedinsurrogatequalicationtesting.
3.Maximumproductwaterlevelwasnotobservedbutwassetatthedetectionlimitoftheanalysis.
4.maximumproductwaterlevelissetatavaluedeterminedinsurrogatequalicationtesting.
5.Chemicalreductionpercentandmaximumproductwaterlevelcalculatedatchloroform95%breakthroughpointasdeterminedinsurrogate
qualicationtesting.
6.Thesurrogatetestresultsforheptachlorepoxidedemonstrateda98%reduction.Thesedatawereusedtocalculateanupperoccurrence
concentrationwhichwouldproduceamaximumproductwaterlevelattheMCL.
* VOC Surrogate Claims
WoongjinCoway.,Ltd.
658,Yugu-Ri,YuguEub,Gongju-Si,Choongchungnam-Do,Korea
Tel.:82-41-850-7879Fax.:82-41-841-7816
37
MEMO
PERFORMANCE DATA SHEET | CHP-03AU
Others
38
What This Warranty Covers:
Commencingwiththedateofpurchaseofthe
Productandcontinuingforaperiodofoneyear,
ifmanufacturingdefectsintheProductcausethe
Producttonotoperateproperlyforitsintended
use,thensubjecttotheexclusions,conditions,and
limitationscontainedherein,COWAYatitssole
optionwillrepairorreplacetheProduct.
Decisionsastotheextentofrepairorreplacement
requiredwillbemadesolelybyCOWAY.
TheremedyunderthisWarrantyisavailableonly
forthatportionoftheProductexhibitingdefects
atthetimeofthewarrantyclaim.Thereplacement
ProductaswellasanyremainingoriginalProduct
willbewarrantedonlyfortheoriginaloneyear
warrantyperiod.Thislimitedwarrantyapplies
onlytoProductusedforanapplicationspecied
byCOWAYfortheProductandappliedinstrict
accordancewithCOWAYpublishedspecications
ineectatthetimeofapplication.IFPRODUCTIS
USEDFOROTHERTHANITSINTENDEDPURPOSE,
ITISSOLDASISANDWITHOUTANYEXPRESS
ORIMPLIEDWARRANTIES,INCLUDINGOF
MERCHANTABILITYORFITNESSFORAPARTICULAR
PURPOSE.
What This Warranty Does Not Cover:
ThisWarrantywarrantsthattheProductwillbe
freefrommanufacturingdefectswhichaectthe
abilityoftheProducttooperateforitsintended
use;itisnotawarrantythattheProductwillnever
requirerepairsortoundertakeresponsibilities,
liabilitiesorobligationsotherthanthose
specicallyidentiedintheprecedingsection.
COWAYisnotresponsibleorliableforpersonal
injuryorpropertydamageofanykind,evenif
arisingfromabreachofthisWarranty.
Limitations and Exclusions:
TOTHEEXTENTPERMITTEDBYAPPLICABLELAW,
COWAYDISCLAIMSANYOTHERWARRANTY
EXPRESSORIMPLIED,THANTHATPROVIDED
FORHEREIN.THISWARRANTYISINLIEUOFAND
EXCLUDESALLOTHERWARRANTIES,GUARANTEES,
CONDITIONSANDREPRESENTATIONS,EXPRESS
ORIMPLIED,ORALORWRITTEN,STATUTORYOR
OTHERWISE,INCLUDINGBUTNOTLIMITEDTO
ANYIMPLIEDCONDITIONSORWARRANTIESAS
TOTHEMERCHANTABILITYORFITNESSFORA
PARTICULARPURPOSEOFTHECOWAYPRODUCT.
SOMESTATESDONOTALLOWLIMITATIONSON
HOWLONGANIMPLIEDWARRANTYLASTS,SO
THEABOVELIMITATIONMAYNOTAPPLYTOYOU.
COWAYDOESNOTAUTHORIZEANYPERSON
INCLUDINGITSREPRESENTATIVES,TOMAKEANY
REPRESENTATIONORTOOFFERANYWARRANTY,
CONDITIONORGUARANTYINRESPECTOFTHE
PRODUCTOTHERTHANTHISWARRANTY.THIS
LIMITEDWARRANTYSHALLBETHEOWNER’S
SOLEANDEXCLUSIVEREMEDYAGAINST
COWAYANDCOWAYSHALLNOTBELIABLEFOR
ANYCONSEQUENTIAL,EXEMPLARY,SPECIAL,
INCIDENTALOROTHERDAMAGESINCLUDING,
BUTNOTLIMITEDTO,LOSSOFPROFITS,AND
LOSSOFUSE.INCIDENTAL,CONSEQUENTIAL
ANDEXEMPLARYDAMAGESSHALLNOTBE
RECOVERABLEEVENIFTHEREMEDIESORTHE
ACTIONSPROVIDEDFORINTHISWARRANTYFAIL
OFTHEIRESSENTIALPURPOSE.SOMESTATESDO
NOTALLOWTHEEXCLUSIONORLIMITATIONOF
INCIDENTALORCONSEQUENTIALDAMAGES,SO
THEABOVELIMITATIONOREXCLUSIONMAYNOT
APPLYTOYOU.COWAYSHALLNOTBELIABLE
FORANYDAMAGESWHICHAREBASEDUPON
NEGLIGENCE,BREACHOFWARRANTY,STRICT
LIABILITYORANYOTHERLEGALTHEORYOF
LIABILITYOTHERTHANTHEEXCLUSIVELIABILITY
SETFORTHINTHISWARRANTY
WARRANTY CARD OR WARRANTY LETTER
ONE YEAR LIMITED WARRANTY
WATER FIRTRATION DEVICE CHP-03AR/L/U (“PRODUCT”)
Model:
Serial Number:
Customer Name: (“OWNER”)
Date of Purchase:
39
Limitations on Implied Warranties:
Anyimpliedwarrantyofmerchantabilityor
tnessforaparticularpurposeoruse,shallbe
limitedtothedurationoftheforegoingexpress
writtenwarranty.
Conditions of Warranty:
COWAY’scontinuingliabilityunderthis
Warrantyisconditioneduponthefollowing:
a) Thedefectordamageisnotcaused
byoristheresultof:abnormaluseor
conditions;improperstorage,unauthorized
modicationsorrepair;misuse,neglect,
accident,alteration,improperinstallationor
otheractsthatarenotthefaultofCowayor
themanufactureroftheproductorthatare
notcoveredbythemanufacturer’swarranty;
b) TheProducthasnotbeenaltered,modied
orrepairedwithoutpriorwrittenapprovalof
COWAY;
c) TheOWNERhasnotiedCOWAYinwriting
ofanyfailureoftheProductcoveredbythis
Warrantywithinthirty(30)daysfollowing
suchfailure;
d) Therehasbeennomisuse,abuseor
negligencewithrespecttotheProducton
thepartoftheOWNER.
Waiver:
COWAY’sfailureatanytimetoenforceorrely
uponanyofthetermsorconditionsstated
hereinshallnotbeconstruedtobeawaiverof
itsrightshereunder.
Obtaining Warranty Service and OWNER’S
Duties:
IftheProductfailstooperateforits
intendedpurpose,thennotifyCowayorits
RepresentativeAgencywithin48hoursor
withinthenextbusinessdayafterdiscovery
ofanydefectintheProduct.TheOWNERmust
givewrittennoticetoCOWAYnolaterthan
thirty(30)daysafteradefectisdiscoveredor
shouldbyreasonablediligencehavebeen
discovered.ClaimsunderthisWarrantywill
requireproofofpurchasebytheOWNER.
USA
Add :WOONGJINCOWAYUSA,INC.
695SOUTHVERMONT,STE.110(SOUTHTOWER)LOSANGELES,CA90005,USA
Callcenter. :(213)386-9900/(213)480-1600
Fax. :(213)386-3990
WARRANTY CARD
Others
40
http://www.coway.com MADEINKOREA
1210108
001