Coway P 07Cl Users Manual
P-07CL to the manual 74ca4a74-f8c0-4996-a48e-20d49b7f097b
2015-02-05
: Coway Coway-P-07Cl-Users-Manual-534828 coway-p-07cl-users-manual-534828 coway pdf
Open the PDF directly: View PDF
.
Page Count: 28

P-07CL
Water Filtration Device
• Foryoursafetyandproperuseoftheproduct,pleasereadthis
User’sManualbeforeuse.
• WarrantycardisincludedinthisUser’sManual.

1
FEATURES
1. Continuous extraction function
Ifyouletthecokeleverdown,asyoucanextractthewater
continuouslyinastateofstoppedlever,itisconvenient.
2. Uniform water pressure keeping function
Intheareawiththehighwaterpressure,itprotectstheinsideof
theproductfromthehighwaterpressurebyprovidingamain
waterwithanuniformedwaterpressure.
3. Closed tank for preventing the secondary
pollution
Itisthehygienicbyapplyingtheextraclosedstructure
totheinnertanktopreventingthesecondarypollutiondueto
theintrusionofadust,worm,andotherforeignbody.
4. Compact, Slim Design
Thecompact,slimdesigntsanysmallspaceinyourkitchen.
Uninformed water
pressure keeping
Uninformed water
pressure keeping
Continuous
extraction
Continuous
extraction
Secondary
pollution
prevention
Secondary
pollution
prevention

ThankyouforusingCoway Water Filtration Device.
PleasereadthisUsers’Manualtouseandmaintaintheproductcorrectly.Ifyouencountera
problemwhileusingtheproduct,youmaysolvetheproblemreferringtotheUser’sManual.
Asthismanualcontainstheproductwarrantycard,pleasekeepitinasafeplace.
ThissystemconformstoNSF/ANSI42foraestheticchlorinereductionandNSF/ANSI53forVOC
reductionasveriedandsubstantiatedbytestdata.
ThissystemconformstoNSF/ANSI58forthereductionofpentavalentarsenic,barium,cadmium,
selenium,radium226/228,trivalentchromium,hexavalentchromium,lead,nitrate/nitriteas
veriedandsubstantiatedbytestdata.
Seeperformancedatasheetforindividualcontaminantsandreductionperformance.
Thissystemisacceptablefortreatmentforinuentconcentrationsofnomorethan27mg/
Lnitrateand3mg/LnitriteincombinationmeasuredasNandiscertiedfornitrate/nitrite
reductiononlyforwatersupplieswithapressureof280kPa(40psi)orgreater.
2
Coway
FEATURES / CONTENTS
DEAR CUSTOMERS
- Please keep the User’s Manual where it can be readily reached or found -
CONTENTS
FOR INFORMATION
SAFETY INFORMATION ...................3
Installationsafety...................... 3
Operationsafety....................... 3
Others................................. 4
PARTS NAME ............................5
WATER FILTRATION PROCESS .............6
HOW TO USE
INSTALLATION PRECAUTIONS ............7
HOW TO USE .............................9
Todrinktheroomwater ............... 9
Toextractcontinuously. . . . . . . . . . . . . . . . 9
MAINTENANCE
INSTALLATION ..........................10
CLEANING METHOD ....................12
Storagetank..........................12
FILTER REPLACEMENT ...................15
FILTER REPLACEMENT METHOD .........16
OTHERS
TROUBLESHOOTING ....................18
SPECIFICATIONS ........................19
WATER FLOW DIAGRAM .................20
PERFORMANCE DATA SHEET ............21
WARRANTY CARD .......................25

3
SAFETY INFORMATION
Ifnotobserved,
seriousinjuryor
evendeathcould
occur.
Ifnotobserved,
seriousinjuryor
propertydamage
couldoccur.
Ifnotobserved,slight
injuryorproperty
damagecouldoccur.
Danger Warning Caution
Installation safety
Do not install near a
heating device.
Otherwise,remayoccuras
aresult.
Do not install the
product on a sloped
oor.
Injurytotheuserordamage
totheunitmayresult.
Do not press the product
by constraint or impact.
Injurytodamagetotheunit
mayresult.
The ltration device installation shall
comply with applicable state and local
regulations.
Operation safety
When the water is
coming inside of the
product or there is a
puddle on the product,
call Service Center after
closing the supplying
valve and unplugging.
Otherwise,electricshockmay
occurasaresult.
If our product produces a
strange noise or odd
smell, immediately
unplug from the
electrical outlet and call
our Service Center.
Otherwise,electricshockor
remayoccurasaresult.
Be careful to keep this safety information.
Pleasereadthissafetyinformationcarefullytoensureyoursafetyandtopreventpossible
propertydamageorloss.

4
For Information
SAFETY INFORMATION | Installation safety | Operation safety | Others
Do not put the candle, a
light for cigarette on the
products.
Otherwise,remayoccuras
aresult.
Do not place any
containers with water,
medicine, food, small
metallic objects, or any
ammable material on
the top of the product.
Inthecaseforeignmaterial
getsinsidetheproduct,
electricshock,re,product
damagemayoccurasaresult.
To drink the ltered,
change the lter
according to the lter
replacement cycle.
Ifyouusetheexpiredlter,
thelterperformanceis
lowered.
Use after closing the
water tank cover
completely inside of the
product.
Thebuckortheforeignbody
canbeentered.
Others
Do not clean by spraying
the water directly or
don’t wipe the product
using the benzene and
thinner.
Otherwise,electricshockor
remayoccurasaresult.
Do not repair,
disassemble, or modify.
Otherwise,electricshockor
productdamagemayoccur
asaresult.
Do not use ltered water
for the water exchange
of an aquarium or a
shbowl.
Theroomwaterthroughthe
membraneisn’tsuitablefor
thesh’slifeenvironmentas
itremovedtheionicmaterial.
Insomecases,shesmight
evendie.
After moving the product
or replacing the inno-
sense lter, the black
powder can be remained
in the inner bottom of
the water tank.
Itisquietharmlessasthe
powderoftheactivated
carbonusedintheinno-sense
lterwasowedoutfor
improvingthewatertastes.
Rotate with grasping the
ltered water extraction
faucet or don’t raise the
product using the faucet.
Otherwise,theleakagemay
beoccurredorproductmay
break.
Do not use with water
that is microbiologically
unsafe or of unknown
quality without adequate
disinfection before or after
the system.

PARTS NAME
Front
Rear
Top Cover
Inlet(Orange)
Outlet(Blue)
Extraction Lever
Room water Extraction Faucet
Front Cover
5

WATER FILTRATION PROCESS
The 5-step Water Filtering System
Step 1, 2 : NEO-SENSE FILTER
Thisneo-senselterhasthefunctiontoreduceaestheticchlorine,odor,volatileorganic
compounds(VOC’s).
Step 3 : RO MEMBRANE FILTER
ROmembranelterhasthefunctiontoreducewatercontaminantssuchaspentavalentarsenic,
barium,cadmium,selenium,radium226/228,trivalentchromium,hexavalentchromium,lead,
nitrate/nitrite.
Step 4 : INNO-SENSE FILTER
Thisinno-senselterhasthefunctionstoreducesmellinductionmaterialandtoimprovetasteof
water.Italsohasthefunctiontoreduceaestheticchlorine,volatileorganiccompounds(VOC’s).
Step 5 : CERAMIC FILTER
Thelteristhecoretechnologyoftheltrationsystem.
Ifyoudon’tusequalifyinglterorifyouuseanoldlterthathasexpired,
thesystemperformancemaydegrade.
Uses of reject water
- Therejectwatershouldbeusedforcleaningtherestroom,thehouse,clothes,or
purposesotherthandrinking.
- Neverusetherejectwaterforadrinkingorcooking.
Tips
Reject
Water
Outlet CERAMIC
FILTER
NEO-SENSE
FILTER
ROMEMBRANE
FILTER
INNO-SENSE
FILTER
CERAMIC
FILTER
6
For Information
PARTS NAME / WATER FILTRATION PROCESS

INSTALLATION PRECAUTIONS
The summary for the proper installation of the water ltration device
1. Close main water supply valve to separate the faucet.
2. Apply the teon tape on the adaptor and t it to the
pipe.
3. Connect the faucet with the adaptor.
4. Connect 1/4 inch orange tubing with the connector
on the adaptor.
5. Open the feed valve to supply water to the ltration
system.
Do not tum the water pipe.
Install the adaptor with connector to the cold water pipe.
Flush water through each lter at least 5 minutes before
Connection.
7

Please check before use!
• Openthemainwatersupplyvalve.
Themainwatermustbesuppliedtooperatethewaterltrationdevicenormally.
• Afterinstallingtheproduct
Getridofthesavedwaterabovethefullwaterintheinnerwatertank2timesormoretouse.
• Whenyoudidn’tuseforalongtime
Ifyousavedthewaterforalongtimeoryoudidn’tuse,drainthewaterinsideofthewater
ltrationdevicecompletelyandremovethenewlylteredwateronetimetouse.
• Regularlterreplacement
Itisimportanttoreplacethelterregularlytomaintainwaterqualityasitisdesigned.Ifthelter
isoverusedbeyonditsservicelife,theperformanceofthewaterltrationdevicedeteriorate.Do
notmissthelterreplacementcycle.
Whenyoudon’tuseforalongtime,closethemainwatersupplyvalve.
Tips
8
How to Use
INSTALLATION PRECAUTIONS

HOW TO USE
To drink the room water
Ifyoupulltheextractionleverdownward,youcandrink
thelteredwater.
To extract continuously
Pleasextheleverbylettingextractionleverdown
about90˚.
9

INSTALLATION
Follow the instruction for installation
Connecttheorangecolorinlettubing 1
to the tap water
supplying pipe. Connect the outlet tubing
2.
Outlettubing
(Blue)
Inlettubing
(Orange)
2
1
Mainwater
supplyvalve
10
Maintenance
HOW TO USE | To drink the room water | To extract continuously / INSTALLATION

INSTALLATION
Be cautious!
Water ltration device installation place 1
Pleaseinstallthewaterltrationsystemnotataroughplace,adamp
place,aplacewheretheunitisexposedtothedirectsunlight,a
placewheredustispresent,oraplacethatthewaterdrops.
Water ltration device installation place 2
Pleaseinstallattheplacewhereitis10cmormoreofromthewall
andthebottomisatandrm.
After installing the water ltration system
Pleaseemptythewatertanklledwithlteredwatertwotimesafter
theproductinstallation.
Cold water plumbing
Pleaseconnectthesourcewater.Makesurethatthesourcewateris
notfromhotwaterline.Ifyouusehotwaterassourcewater,then
itwillcausepermanentdamagestoROmembraneandseverely
degradetheproductperformance.
Hot water Pipe
1O Cm
Tomaintainoptimalproductperformance,consultaCowayengineerforthedetailed
installationmethods.
Theremaybesomewaterremaininginsideofthelterwhichwasusedtotestthe
productduringinspectionprocessatthefactory.
Pleasefeelateasyanduseasitisn’ttheusedproduct.
Don’treusethemainwatersupplyvalveandhosethatwaspreviously
usedwhenyoure-installtheproduct.
Tips
11

CLEANING METHOD
Storage tank
1. Close the main water supply valve.
2. Please empty the water tank completely using
the continuous extraction method (See P.9).
3. Please remove the top cover, and then un-hook the xed clip holding the
top cover of the water tank. Now open the tank cover.
1
21
12
Maintenance
INSTALLATION / CLEANING METHOD | Storage tank

CLEANING METHOD
4. Please install again after separating the ceramic lter from the water tank
cover and shaking and cleansing in the drained water.
5. Please wipe the surface of the storage tank with
soft clothes.
6. Use the storage tank after cleaning it with the drained water, and empty
the water tank using the continuous extraction method.
7. Close the water tank cover and assemble the xing clip.
2
2
1
1
13

8. Close the upper cover, and open the main water supply valve.
Closethestoragetankcovercompletely.
Insectsorotherforeignparticlescanbeentered.
Whenyoucleanthestoragetank,don’tuseanychemicalsor
detergent.
Ifyoudon’tcleanchemicalsordetergentcleanly,itcanbe
harmfultothebody.
- Keepthesurroundingscleanandcleanthestoragetankonce
pertwomonths.
Tips
14
Maintenance
CLEANING METHOD | Storage tank

FILTER REPLACEMENT
Filter
Filterisacriticalcomponentforawaterltrationsystem.Replacing
authorizedltersataspeciedreplacementcycleisimportanttomaintain
thewaterquality,andapropersystemoperation.Pleasereplaceltersata
speciedreplacementcycle.Forreplacementlters,pleasecontactCoway
authorizeddealersanddistributors.
Filter replacement cycle
Ifthelterisnotregularlyreplaced,itmaydegradethewaterqualityfrom
theproduct.Thesourcewaterqualitycanshortenthelterreplacement
period.
Theperiodforthelterexchangeismadebasedon10Luseinadayfor
houseuse(4peoplebased)useforbusiness.
P-07CL
Part No. Names of Filter Replacement Cycle
WJNF8-S Neo-senselter 6months
WJMF8-20-S Romembranelter 20months
WJIF8-S Inno-senselter 18months
WJCC-02 Ceramiclter 12months
About lter replacement cycle
Thelterreplacementcycledescribedaboveisnotthelterquality
warrantyperiodbuttheexpectedcycle(life)thattheltershowsits
originalperformance.
Therefore,thelterreplacementcyclemaybereducedfortheareawith
thepoorwaterqualityormorewaterconsumption.
15

FILTER REPLACEMENT METHOD
1. Close the main water supply valve and drain the water inside of the water
ltration device (See P.12).
2. Separate the top cover and the front cover.
(Remove the 2 xing screws at the top of the product and then separate
the front cover.)
Don’tpulltheCup-touchLeverwiththeexcesspower.
Otherwise,theproductmaybreak.
Tips
1
1
2
16
Maintenance
FILTER REPLACEMENT / FILTER REPLACEMENT METHOD

FILTER REPLACEMENT METHOD
3. After separating the tting connected to the lter trying to replace, please
replace the lter. (Separate the tting using the proper tool.)
4. Close the front cover aligning the grooves and then fasten the 2 screws
xing the front cover.
Close the top cover.
Whenyouarereplacinglters,pleasemakesurethatacorrespondinglteranda
hosearermlyconnectedandthatthereisnoleakage.Itisrecommendedtoempty
thewatertanklledwiththelteredwateratleastonetimerightafterthelter
replacement.
Tips
Beforeinstallinganewlter,pleasedotheltercleansingrstasdirectedbelow:
Tips
Filter Name Cleansing Time Comment
Neo-senselter 30seconds
Inno-senselter 3minutes PleaseuseNeo-senselteredwaterforcleansing
Romembranelter 3minutes PleaseuseNeo-senselteredwaterforcleansing
17

TROUBLESHOOTING
Symptom Check Measures to take
Thewatertastes
weird.
• Didyoucleanthestoragetank? Cleanthestoragetank.
• Youdidn’tusethewaterltrationdevice
foralongtime.
Getridofthesavedwaterandcleanthe
storagetank.
• Isn’titabouttimetochangethelter? Requestthelterreplacement.
Thewaterdoesn’t
come.
• Isthewatersupplycutorisn’tthewater
supplyvalveclosed? Openthemainwatersupplyvalve.
• Thewaterextractionfaucetisoutof
order. Inthiscase,pleasecontactaservicecenter.
• Didyoumissthelterreplacementtimes? Requestthelterreplacement.
Thewateris
owingslower.
• Isn’titabouttimetochangethelter? Requestthelterreplacement.
• Didn’tyouclosethemainwatersupply
valve? Openthemainwatersupplyvalve.
• Didn’tthetemperatureofthemainwater
dropsuddenly?
Ifthewatertemperatureislowered,the
wateramountisdecreased.
Aleakagewas
occurred.
• Doesn’tthewaterinsideofthestorage
tankcoverorthewaterltrationdevice
owout?
Checkbyopeningtheuppercoverand
requesttheserviceafterclosingthemain
watervalve.
ThewaterFiltrationdevicemayoperateabnormallyduetominorcausesnotbecauseofthe
productmalfunctionbutbecauseofthefactthattheuserisnotfamiliarwiththeproductuse.
Insuchacase,problemscanbesolvedeasilyevenwithoutthehelpfromtheServiceCenterby
checkingthefollowingitems.Ifyoucan’tsolvetheproblemaftercheckingthefollowingitems,
pleasecalltheServiceCenter.
18
Others
FILTER REPLACEMENT METHOD / TROUBLESHOOTING

19
SPECIFICATION
Product Water Filtration Device
Model P-07CL
FiltrationMethod RO(ReverseOsmosis)
TankCapacity 3.9L
Dimension 200mm(W)×390mm(D)×370mm(H)
WorkingTemperature 5°C-35°C
ProductionRate 76.8L/d(25°C,138kPa)
WorkingPressure 138kPa–827kPa
NetWeight 4.5kg
• Thewateramountcanbedierentiatedaccordingtothewaterpressureandthewater
temperature.
• Thewatertankcapacityistheamountbythesizeandcanbedierentfromtheextraction
capacity.
• Withoutanypriornotice,allorpartsoftheproductaresubjecttochangeforthepurposeof
improvingtheperformanceoftheproduct.
• RefertoPerformancedatasheetforindividualcontaminants,reductionperformanceandgeneral
operatinginformation.

WATER FLOW DIAGRAM
P-07CL
Inno-sense
Filter
3FHVMBUPS
%'-$
20
Others
SPECIFICATION / WATER TER FLOW DIAGRAM

Water Filtration System Performance Data Sheet
Brand: Neos Model: P-07CL
ThissystemhasbeentestedandcertiedbytheWaterQualityAssociationaccordingtoNSF/ANSI42,53,and58for
thereductionofthesubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwaterenteringthe
systemwasreducedtoaconcentrationlessthanorequaltothepermissiblelimitforwaterleavingthesystem,as
speciedinNSF/ANSI42,53,and58.
Substance
Max.Allowable
Concentration
(mg/L)
Average
Inuent
(mg/L)
Average
Euent
(mg/L)
Minimum
Percent
Reduction(%)
Average
Percent
Reduction(%)
Arsenic(Pentavalant) 0.010 0.05 0.006 79.1 87.7
Barium 2.0 10 1.4 83.5 86.6
Radium226/228 5pCi/L 25pCi/L 5pCi/L N/A N/A
Cadmium 0.005 0.031 0.002 89.0 92.7
Chromium(Hexavalent) 0.1 0.358 0.023 93.8 95.1
Chromium(Trivalent) 0.1 0.367 0.028 93.8 95.7
Lead 0.010 0.153 0.005 93.6 95.1
Nitrate/Nitrite 10 29.6 4.8 78.5 83.7
Selenium 0.05 0.117 0.003 96.0 97.8
TDS <187.5 741.5 57.8 91.5 92.2
AestheticChlorine ≥50% 2.07 0.56 54.53 72.8
VOC* ≥95%reduction 0.32 0.0077 95.70 97.6
Whiletestingwasperformedunderlaboratoryconditions,actualperformancemayvary.
General Operating Information:
RatedCapacity 165gallons(forVOC)
4,400gallons(forAestheticChlorine)
Min-Maxoperatingpressure: 20~120psi(1.4~8.4kgf/cm2)
Min-Maxfeedwatertemperature: 41~95ºF(5~35ºC)
RatedServiceFlow 0.07GPM(forVOC)
0.5GPM(forAestheticChlorine)
DailyWaterProductionRate 42GPD
ProductEciencyRating 26.5%
• Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfection
beforeorafterthesystem.
• Refertotheownersmanualforspecicinstallationinstructions,manufacturer’slimitedwarranty,user
responsibility,andpartsandserviceavailability.
• Theinuentwatertothesystemshallincludethefollowingcharacteristics:
o Noorganicsolvents
o Chlorine:<2ppm
o pH:7-8
o Temperature:41~95ºF(5~35ºC)
o Iron:<2ppm
o Turbidity:<1NTU
o Hardness:<1000mg/L
21

• Forpartsandserviceavailability,pleasecontactyourlocaldealerorCoway.
• Thissystemisacceptablefortreatmentofinuentconcentrationsofnomorethan27mg/Lnitrateand3mg/L
nitriteincombinationmeasuredasNandiscertiedfornitrate/nitritereductiononlyforwatersupplieswitha
pressureof2.8kgf/cm2(40psi)orgreater.
• Anitrate/nitritesamplingkitshouldbeusedtomonitorthenitrate/nitritelevelsinyourproductdrinkingwater
atleasteverysixmonths.KitsmaybepurchasedfromyourlocaldealerorCoway.
• Thissystemhasbeentestedforthetreatmentofwatercontainingpentavalentarsenic(alsoknowasAs(V),
As(+5),orarsenate)atconcentrationsof0.050mg/Lorless.Thissystemreducespentavalentarsenic,but
maynotremoveotherformsofarsenic.Thissystemistobeusedonwatersuppliescontainingadetectable
freechlorineresidualatthesysteminletoronwatersuppliesthathavebeendemonstratedtocontainonly
pentavalentarsenic.Treatmentwithchloramines(combinedchlorine)isnotsucienttoensurecomplete
conversionoftrivalentarsenictopentavalentarsenic.PleaseseetheArsenicFactssectionofthisPerformance
DataSheetforfurtherinformation.
• Eciencyratingmeansthepercentageoftheinuentwatertothesystemthatisavailabletotheuserasreverse
osmosistreatedwaterunderoperatingconditionsthatapproximatetypicaldailyusage.
• Theproductwatershouldbetestedevery6monthstoensurethatthecontaminantsarebeingreduced
eectively.PleasecontactyourlocaldealerorCowaytoinitiatethisservice.
• Thisreverseosmosissystemcontainsareplaceabletreatmentcomponents,criticalfortheeectivereductionof
totaldissolvedsolidsandthatproductwatershallbetestedperiodicallytoverifythatthesystemisperforming
properly.Replacementofreverseosmosiscomponentshouldbewithoneofidenticalspecications,asdened
bythemanufacturer,toassurethesameeciencyandcontaminantreductionperformance.
• Theestimatedreplacementtimeoflter,whichisaconsumablepart,isnotanindicationofqualityguarantee
period,butitmeanstheidealtimeoflterreplacement.Accordingly,theestimatedtimeoflterreplacement
maybeshortenedincaseitisusedinanareaofpoorwaterquality.
ModelofFilter Type Usableperiod(months) COSTUS$
WNF8-S NEO-SENSEFILTER 6 46.00
WJMF8-20-S ROMEMBRANEFILTER 20 94.00
WJIF8–S INNOSENSEFILTER 18 47.00
WJCC-02 CERAMICFILTER 12 11.00
ARSENIC FACTS
Arsenic(abbreviatedAs)isfoundnaturallyinsomewellwater.Arsenicinwaterhasnocolor,tasteorodor.Itmust
bemeasuredbyalabtest.Publicwaterutilitiesmusthavetheirwatertestedforarsenic.Youcangettheresults
fromyourwaterutility.Ifyouhaveyourownwell,youcanhavethewatertested.Thelocalhealthdepartment
orthestateenvironmentalhealthagencycanprovidealistofcertiedlabs.Thecostistypically$15to$30.
InformationaboutarsenicinwatercanbefoundontheInternetattheUSEnvironmentalProtectionAgency
website:
www.epa.gov/safewater/arsenic.html
Therearetwoformsofarsenic:pentavalentarsenic(alsocalledAs(V),As(+5),andarsenate)andtrivalentarsenic
(alsocalledAs(III),As(+3),andarsenite).Inwellwater,arsenicmaybepentavalent,trivalent,oracombinationof
both.Specialsamplingproceduresareneededforalabtodeterminewhattypeandhowmuchofeachtypeof
arsenicisinthewater.Checkwiththelabsinyourareatoseeiftheycanprovidethistypeofservice.
Reverseosmosis(RO)watertreatmentsystemsdonotremovetrivalentarsenicfromwaterverywell.ROsystems
areveryeectiveatremovingpentavalentarsenic.Afreechlorineresidualwillrapidlyconverttrivalentarsenic
topentavalentarsenic.Otherwatertreatmentchemicalssuchasozoneandpotassiumpermanganatewillalso
changetrivalentarsenictopentavalentarsenic.Acombinedchlorineresidual(alsocalledchloramine)maynot
convertallthetrivalentarsenic.Ifyougetyourwaterfromapublicwaterutility,contacttheutilitytondoutiffree
chlorineorcombinedchlorineisusedinthewatersystem.
TheP-07CLsystemisdesignedtoremovepentavalentarsenic.Itwillnotconverttrivalentarsenictopentavalent
arsenic.Thesystemwastestedinalab.Underthoseconditions,thesystemreduced0.050mg/Lpentavalent
arsenicto0.010mg/L(ppm)(theUSEPAstandardfordrinkingwater)orless.Theperformanceofthesystemmaybe
dierentatyourinstallation.Havethetreatedwatertestedforarsenictocheckifthesystemisworkingproperly.
TheROcomponentoftheP-07CLsystemmustbereplacedevery24monthstoensurethesystemwillcontinueto
removepentavalentarsenic.Thecomponentidenticationandlocationswhereyoucanpurchasethecomponent
arelistedintheinstallation/operationmanual.
22
Others
PERFORMANCE DATA SHEET | P-07CL

23
* VOC Surrogate Claims
Chemical Drinkingwaterregulatory
level1(MCL/MAC)mg/L
Inuentchallenge
concentration2mg/L
Chemicalreduction
percent
Maximumproductwater
concentrationmg/L
alachlor 0.002 0.050 >98 0.0013
atrazine 0.003 0.100 >97 0.0033
benzene 0.005 0.081 >99 0.0013
carbofuran 0.04 0.190 >99 0.0013
carbontetrachloride 0.005 0.078 98 0.00184
chlorobenzene 0.1 0.077 >99 0.0013
chloropicrin - 0.015 99 0.00023
2,4-D 0.07 0.110 98 0.00174
dibromochloropropane(DBCP) 0.0002 0.052 >99 0.000023
o-dichlorobenzene 0.6 0.080 >99 0.0013
p-dichlorobenzene 0.075 0.040 >98 0.0013
1,2-dichloroethane 0.005 0.088 9550.00485
1,1-dichloroethylene 0.007 0.083 >99 0.0013
cis-1,2-dichloroethylene 0.07 0.170 >99 0.00053
trans-1,2-dichloroethylene 0.1 0.086 >99 0.0013
1,2-dichloropropane 0.005 0.080 >99 0.0013
cis-1,3-dichloropropylene - 0.079 >99 0.0013
dinoseb 0.007 0.170 99 0.00024
endrin 0.002 0.053 99 0.000594
ethylbenzene 0.7 0.088 >99 0.0013
ethylenedilbromide(EDB) 0.00005 0.044 >99 0.000023
haloacetonitriles(HAN):
bromochloroacetonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetoritrile
-
-
-
-
0.022
0.024
0.0096
0.015
98
98
98
98
0.00053
0.00063
0.00023
0.00033
haloketones(HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
-
-
0.0072
0.0082
99
96
0.00013
0.00033
heptachlor(H-34,Heptox) 0.0004 0.08 >99 0.0004
heptachlorepoxide 0.0002 0.0107698 0.00026
hexachlorobutadiene - 0.044 >98 0.0013
hexachlorocyclopentadiene 0.05 0.060 >99 0.0000023
lindane 0.0002 0.055 >99 0.000013
methoxychlor 0.04 0.050 >99 0.00013
pentachlorophenol 0.001 0.096 >99 0.0013
simazine 0.004 0.120 >97 0.0043
styrene 0.1 0.150 >99 0.00053
1,1,2,2-tetrachloroethane - 0.081 >99 0.0013
tetrachloroethylene 0.005 0.081 >99 0.0013
toluene 10.078 >99 0.0013
2,4,5-TP(silvex) 0.05 0.270 99 0.00164
tribromoaceticacid - 0.042 >98 0.0013
1,2,4-trichlorobenzene 0.07 0.160 >99 0.00053
1,1,1-trichloroethane 0.2 0.084 95 0.00464
1,1,2-trichloroethane 0.005 0.150 >99 0.00053
trichloroethylene 0.005 0.180 >99 0.00103
trihalomethanes(includes):
chloroform(surrogatechemical)
bromoform
bromodichloromethane
chlorodibromomethane 0.080 0.300 95 0.015
xylenes(total) 10 0.070 >99 0.0013
1. TheseharmonizedvalueswereagreeduponbyrepresentativesofUSEPAandHealthCanadaforthepurposeofevaluatingproductstotherequirementsof
thisStandard.
2. Inuentchallengelevelsareaverageinuentconcentrationsdeterminedinsurrogatequalicationtesting.
3. Maximumproductwaterlevelwasnotobservedbutwassetatthedetectionlimitoftheanalysis.
4. Maximumproductwaterlevelissetatavaluedeterminedinsurrogatequalicationtesting.
5. Chemicalreductionpercentandmaximumproductwaterlevelcalculatedatchloroform95%breakthroughpointasdeterminedinsurrogatequalication
testing.
6. Thesurrogatetestresultsforheptachlorepoxidedemonstrateda98%reduction.Thesedatawereusedtocalculateanupperoccurrenceconcentration
whichwouldproduceamaximumproductwaterlevelattheMCL.
WoongjinCoway.,Ltd.
658,Yugu-Ri,YuguEub,Gongju-Si,Choongchungnam-Do,Korea
Tel.:82-41-850-7879Fax.:82-41-841-7816

MEMO
24
Others PERFORMANCE DATA SHEET | P-07CL

WARRANTY CARD OR WARRANTY LETTER
ONE YEAR LIMITED WARRANTY
WATER FIRTRATION DEVICE P-07CL(“PRODUCT”)
Model:
Serial Number:
Customer Name: (“OWNER”)
Date of Purchase:
What This Warranty Covers:
Commencingwiththedateofpurchaseofthe
Productandcontinuingforaperiodofoneyear,
ifmanufacturingdefectsintheProductcausethe
Producttonotoperateproperlyforitsintended
use,thensubjecttotheexclusions,conditions,and
limitationscontainedherein,COWAYatitssole
optionwillrepairorreplacetheProduct.
Decisionsastotheextentofrepairorreplacement
requiredwillbemadesolelybyCOWAY.
TheremedyunderthisWarrantyisavailableonly
forthatportionoftheProductexhibitingdefects
atthetimeofthewarrantyclaim.Thereplacement
ProductaswellasanyremainingoriginalProduct
willbewarrantedonlyfortheoriginaloneyear
warrantyperiod.Thislimitedwarrantyapplies
onlytoProductusedforanapplicationspecied
byCOWAYfortheProductandappliedinstrict
accordancewithCOWAYpublishedspecications
ineectatthetimeofapplication.IFPRODUCTIS
USEDFOROTHERTHANITSINTENDEDPURPOSE,
ITISSOLDASISANDWITHOUTANYEXPRESS
ORIMPLIEDWARRANTIES,INCLUDINGOF
MERCHANTABILITYORFITNESSFORAPARTICULAR
PURPOSE.
What This Warranty Does Not Cover:
ThisWarrantywarrantsthattheProductwillbe
freefrommanufacturingdefectswhichaectthe
abilityoftheProducttooperateforitsintended
use;itisnotawarrantythattheProductwillnever
requirerepairsortoundertakeresponsibilities,
liabilitiesorobligationsotherthanthose
specicallyidentiedintheprecedingsection.
COWAYisnotresponsibleorliableforpersonal
injuryorpropertydamageofanykind,evenif
arisingfromabreachofthisWarranty.
Limitations and Exclusions:
TOTHEEXTENTPERMITTEDBYAPPLICABLELAW,
COWAYDISCLAIMSANYOTHERWARRANTY
EXPRESSORIMPLIED,THANTHATGUARANTEES
FORHEREIN.THISWARRANTYISINLIEUOFAND
EXCLUDESALLOTHERWARRANTIES,PROVIDES,
CONDITIONSANDREPRESENTATIONS,EXPRESS
ORIMPLIED,ORALORWRITTEN,STATUTORYOR
OTHERWISE,INCLUDINGBUTNOTLIMITEDTO
ANYIMPLIEDCONDITIONSORWARRANTIESAS
TOTHEMERCHANTABILITYORFITNESSFORA
PARTICULARPURPOSEOFTHECOWAYPRODUCT.
SOMESTATESDONOTALLOWLIMITATIONSON
HOWLONGANIMPLIEDWARRANTYLASTS,SO
THEABOVELIMITATIONMAYNOTAPPLYTOYOU.
COWAYDOESNOTAUTHORIZEANYPERSON
INCLUDINGITSREPRESENTATIVES,TOMAKEANY
REPRESENTATIONORTOOFFERANYWARRANTY,
CONDITIONORGUARANTYINRESPECTOFTHE
PRODUCTOTHERTHANTHISWARRANTY.THIS
LIMITEDWARRANTYSHALLBETHEOWNER’S
SOLEANDEXCLUSIVEREMEDYAGAINST
COWAYANDCOWAYSHALLNOTBELIABLEFOR
ANYCONSEQUENTIAL,EXEMPLARY,SPECIAL,
INCIDENTALOROTHERDAMAGESINCLUDING,
BUTNOTLIMITEDTO,LOSSOFPROFITS,AND
LOSSOFUSE.INCIDENTAL,CONSEQUENTIAL
ANDEXEMPLARYDAMAGESSHALLNOTBE
RECOVERABLEEVENIFTHEREMEDIESORTHE
ACTIONSPROVIDEDFORINTHISWARRANTYFAIL
OFTHEIRESSENTIALPURPOSE.SOMESTATESDO
NOTALLOWTHEEXCLUSIONORLIMITATIONOF
INCIDENTALORCONSEQUENTIALDAMAGES,SO
THEABOVELIMITATIONOREXCLUSIONMAYNOT
APPLYTOYOU.COWAYSHALLNOTBELIABLE
FORANYDAMAGESWHICHAREBASEDUPON
NEGLIGENCE,BREACHOFWARRANTY,STRICT
LIABILITYORANYOTHERLEGALTHEORYOF
LIABILITYOTHERTHANTHEEXCLUSIVELIABILITY
SETFORTHINTHISWARRANTY
25

Limitations on Implied Warranties:
Anyimpliedwarrantyofmerchantabilityor
tnessforaparticularpurposeoruse,shallbe
limitedtothedurationoftheforegoingexpress
writtenwarranty.
Conditions of Warranty:
COWAY’scontinuingliabilityunderthis
Warrantyisconditioneduponthefollowing:
a) Thedefectordamageisnotcaused
byoristheresultof:abnormaluseor
conditions;improperstorage,unauthorized
modicationsorrepair;misuse,neglect,
accident,alteration,improperinstallationor
otheractsthatarenotthefaultofCowayor
themanufactureroftheproductorthatare
notcoveredbythemanufacturer’swarranty;
b) TheProducthasnotbeenaltered,modied
orrepairedwithoutpriorwrittenapprovalof
COWAY;
c) TheOWNERhasnotiedCOWAYinwriting
ofanyfailureoftheProductcoveredbythis
Warrantywithinthirty(30)daysfollowing
suchfailure;
d) Therehasbeennomisuse,abuseor
negligencewithrespecttotheProducton
thepartoftheOWNER.
Waiver:
COWAY’sfailureatanytimetoenforceorrely
uponanyofthetermsorconditionsstated
hereinshallnotbeconstruedtobeawaiverof
itsrightshereunder.
Obtaining Warranty Service and OWNER’S
Duties:
IftheProductfailstooperateforits
intendedpurpose,thennotifyCowayorits
RepresentativeAgencywithin48hoursor
withinthenextbusinessdayafterdiscovery
ofanydefectintheProduct.TheOWNERmust
givewrittennoticetoCOWAYnolaterthan
thirty(30)daysafteradefectisdiscoveredor
shouldbyreasonablediligencehavebeen
discovered.ClaimsunderthisWarrantywill
requireproofofpurchasebytheOWNER.
USA
Add :WOONGJINCOWAYUSA,INC.
695SOUTHVERMONT,STE.110(SOUTHTOWER)LOSANGELES,CA90005,USA
Callcenter. :(213)386-9900/(213)480-1600
Fax. :(213)386-3990
26
Others
WARRANTY CARD

http://www.coway.com
1210229
002
MADEINKOREA