SEARS
OWNER'S
MANUAL
Model No. 390.304552

MODELNO.
390.304552
390.304612
390.304692

Model No. 390.304612

Model No. 390.304692

I:RRFTSMRN°
CAUTION:
Read and Follow
All Safety Rulesand
Operating Instructions
Before FirstUse of
This Product.
Save ThisManual For
Future Reference.

SUBMERSIBLE
SUMP PUMP
• Safety Instructions
• Installation
• Electrical
• Service
• Repair Parts

Sears, Roebuck and Co., Hoffman Estates, IL 60179
PRINTED

IN

U.S.A.

U.S.A.

Form NO.

F642-9811

(Rev, 10/22/02)

INTRODUCTION

CONTENTS
1NTROI)I

It 2Tl( )N/\\

SAFH'V

.

2

Plcasc

rczld

no\\

otlr

ill_,trtlctiolls

this

",','ill help

pttmp;

2

vitc

lronl

...........................

3

thai

rt'suh

...............................

i

in O111" %varrallt)

..............................................

5

H.ECFRICAI

PARTS

..................

......................................

INSTALLATION

St:RVICIi

,\ RRA NIS

........................................................

FULL

ONE

it

It will

Irom

als(i

C;lUSeS

bcl_.)rc
yotl

yotl

obtain

help

y(lu

We

CallnOl

install

and

flail valuc

and

avoid

needless

COlttrol

;llld

list

VOllr

gooti scr

service

costs

cautlol

cover

(_7

YEAR

WARRANTY

ON

CRAFTSMAN

® SUBMERSIBLE

SUMP

PUMPS

For one year from the date of purchase, Sears will repair or replace this pump, free of charge, if defective ha material or
workmanship.

LIMITED

WARRANTY

After one year and through
part. YOU pay for labor.

ON CRAFTSMAN*

two years from the date of purchase,

This warranty does not cover repairs or replacement
and operate this pump according
to the instructionsin

1/3-HP SUBMERSIBLE SUMP PUMPS

Sears will furnish,

parts necessary because
the owner's manual.

free of charge,

of abuse

a replacement

or negligence

LIMITATION
OF LIABILITY
SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL

pgrt for 7any defective

including

failure to install, adjust

oR CONSEQUENTIAL

LOSS OR

DIPENSE FROM PROPERTY DAMAGE DUE DIRECTLy OR INDIRECTLY FROM THE USE OF _
PRODUCT
.....
Some states do not allow the exclusion
or limitation Of incidental or consequential
damages, so the above _tation
or exclusion
n0t_apply to you.
WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER/DEPARTMENT
IN THE
UNITED STATES.
Tlfis warranty
This warranty

•

:

applies only whife the product is in use in the UMt_ S ta_ _
gives you specific iegal rights and you mayalso!ia,
de0flfe/figlxswhichvary_m
Sears,

Roebuck

and

Co.,

De]p_

817

read

manual

or

_This

on

and

follow

following
injury!

signal

I
injury,

words

death

[ _.WARNING

injury,

L.
& cAuTioN-,:
_
minor
The

personal
word

portant

and he alert

about

not

about
death

hazards

injury

property
hazards

or major

warns
" about

NOTICE

but

in

_es,

hazards

or property

indicates

related

to the potemial

that will

that
damage

special

or can
damage
will

or

if ignored.
cause

installing

pump

which

plumbing

and electrical

power
cord

pump

to
plug.

cool for 20 minutes
before
Modem
motors
are designed
tures.

water

or put

C. Ground

proceed

as follows

outlet
box
before
plug is pulled, let pump

attempting
to operate

to work
on it.
at high tempera-

codes

your

finger

the electrical

changing
shocks,

fuses.
To reduce
DO NOT stand in

in the fuse socket.
outlet

box.

D. Use only an individual
branch
circuit
with
Fault Circuit
Interrupter
(GFCI) protected
outlet

are im-

to hazards.

national

pump
After

if ignored.

instructions

1. To avoid risk nf serious bodily injury and property damage,
read safety instructions carefully before installing pump.
when

&Disconnect
pulling

seri-

Electrically powered stamp pumps normally give many years of
trouble-free
service when correctly installed, maintained,
and
used. However, unusual circumstances
(interruption
of power
to the pump, dirt/debris
in the sump, flooding that exceeds the
pump's capacity, electrical or mechanical
failure in the pump,
etc.) may prevent your pump from functioning normally. To pre
vent possible water damage due to flooding, consult your local
Sears store about installing a secondary sump pump or a DC
backup sump pump
See "Service", Page 5, for information
about common sump pump problems and remedies.

2. Follow local and/or

shocks,

B. Take extreme
care when
the chance
of fatal electrical

cause

can

OPERATION

per-

ff ignored.

that will
property

serious

AND

_*v_nn._uj
TO avoid fatal
if pump
needs
servicing:

for personal

cause

damage

IL 60179

this

alert symbol.
When you see this symor in this manual,
h)ok for one of the

or major

]warns

ous personal

instructions

3.

warns

sonal

safety

pump.

is the safety,
on your pump

bol

all

state to state.

'¢gA, HO_

RULES FOR SAFE INSTALLATION
Carefully

may

for

cord

a Ground
grounded

plug.

4. Never
run pump
dry. To do so can damage internal
parts,
overheat
the pump
(which
can cause burns to people
handling or servicing
the pump),
and will void the warranty!
5. DO NOT
been put
other
6. This
tions

attempt
to oil the pump
motor.
A special
oil has
into the motor housing
at the factory;
use of any

oil will void the warranty
pump
only.

ADDITIONAL
HATERIALS

is recommended
Pump

water

and could
for use

only with

damage

in permanent

the pump.
installa-

this pump.

INSTALLATION

Sump/Utility
Pump Hose Kit, SEARS Stock No. 27909, containing 24' (7.3M) of 1-1/4" flexible plastic pipe, a 1-1/4" plastic adapter and a stainless steel clamp.
Check

Valve, SEARS Stock

No. 2789.

INSTALLATION
THE SUMP
The sump should be located at the lowest place in the basement or area to be drained. Floor drains from other areas in
the basement
may be tiled into the sump. Drain tile around
a house foundation
can also be tiled into the sump, effectively removing
water and relieving pressure
frorn this area.
A suitable sump can be a 20" or 24" (500_10mm)
sewer tile.
The minimum
size is 12" (305mm)
in diameter
for Models
390.304552
and 390.304612;
10" (254mm)
for Model
390.304692.
A sump
Consult

cover is desirable to exclude refuse from the sump.
local code for sump cover specifications.

NOTICE:
and sump
all refuse.

Periodically
inspect pump, system components,
for debris and foreign objects. Keep sump free of
Perform routine maintenance
as required.

PUMP

INSTALLATION

Set the pump on the bottom of the sump, making sure that
is sits solidly and is level. Be sure there is enough
space
around the pump to allow the switch free movement
as the
sump water level changes.
Pump should not be installed on
clay, earth, or sand surfaces.
[& CAUTION } Risk of flooding.
If a flexible discharge
hose
is used, pump may move around in sump when motor starts.
If it moves far enough so that the switch hits the side of the
sump, the switch may stick and prevent pump from starting.
Make sure that pump is secured
so that it cannot
walk
around in sump.

FLOAT SWITCH
INSTALLATION
AND
OPERATION
(Models 390.304552
and 390.304612;
For Model 390.304692,
see Page 7)
The automatic
float switch is factory mounted
on the pump
and preset for a pumping
range of approximately
7". Tether
length is factory preset at 3-1/2" (89mm) (see Figure 3). Do
not change tether length.
Be sure automatic
float can swing freely through
its entire
arc without
interference
from pump, piping, sump wall or
any other object.
When sump is dry, the watertight
hanging in a downward
position

tape to seal threads

in plastic

pipe.

is

As water comes into the sump, the automatic
float switch
rises to an upward position and the pump starts.
Water will continue
to be pumped
hanging in the downward
position
stop.
IAWARNING]Risk

of electric

until the float switch is
again, when pump will

shock.

Before

installation,

check your local electrical
codes. To avoid personal
when servicing your pump, be sure that the power
connected
from both the pump and the float switch.

injury
is dis-

To check operation,
fill sump with water
ation through
one complete
cycle.

oper-

and observe

Grounded
Electrical

Hose Kit No. 27909 includes
1-1/4" flexible plastic pipe for
the discharge
pipe. Run discharge
pipe to the nearest sewer
outlet or other point of disposal. Use the most direct route
and the fewest turns and elbows possible.
Make sure that
pump cannot move around in sump pit.
Use teflon
only.

automatic
float switch
and the pump is off.

Make sure
pump cannot
move fn sump

Hand tighten

NOTE: To avoid backflow
into sump when pump shuts off,
install a Check Valve, SEARS Stock No. 2789, in threaded discharge port of pump. Be sure arrow on check valve body
points
away from the pump.
This Sears check
valve is
equipped
with an air bleed hole to prevent airlocking pump.
If using any other check valve, drill 1/8" (3.2mm)
hole in
dishcharge
pipe just above pump body but below check
valve to prevent air locks.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 8
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Tue Aug 14 15:49:51 2007
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu