Technical Support 1-800-345-8172                                 Remote Data Port  Page-1www.meieasitrax.com                                                                       Revision G1Mars Inc. 2003 Printed in USA.MEI is a trademark of Mars, Inc. Information is subject to change without notice. MEI has made every effort to ensure that theinformation in this document is accurate. However, we cannot be held responsible for any errors or omissions.Remote Data PortInstall Guide1301 Wilson DriveWest Chester PA 19380www.meieasitrax.comModel:Part No.:Serial No.:Voltage: 24-34VDC, 0.5AMPS
Technical Support 1-800-345-8172                                 Remote Data Port  Page-2www.meieasitrax.com                                                                       Revision G1TABLE OF CONTENTSINTRODUCTIONGeneral Information .............................................................................................. 3Product Features.................................................................................................... 3Interfaces Supported ............................................................................................. 3PRODUCT OVERVIEWSerial Number......................................................................................................... 4Configuration.......................................................................................................... 4Configurable Remote Data Port .......................................................................... 4MEI Easitrax VT1000........................................................................................... 5MEI Easitrax Data Pod 200 ................................................................................. 5Instruction Before Installation ............................................................................. 5Recommended Tools/Supplies .............................................................................. 5Required Installation Standard ............................................................................ 5AUTOMATIC PRODUCT INSTALLATIONAP6000/7000 Series Snack Machine ...............................................................6-8DIXIE NARCO PRODUCT INSTALLATIONDixie Single Price Machine..............................................................................9-11Dixie Narco Motor Cable Chart ........................................................................12RMI PRODUCT INSTALLATIONRMI 2000 / 8050 Machine ............................................................................ 13-15
Technical Support 1-800-345-8172                                 Remote Data Port  Page-3www.meieasitrax.com                                                                       Revision G1INTRODUCTIONGENERAL INFORMATIONThe remote data port lets you add industry-standard DEX data transfer capabilities to machines thatare not audit enabled or add enhanced capabilities to DEX-enabled machines.  The remote data portgathers data on cash transactions and vending cycles, including coin drops, bill insertions and productsales. This information is stored for later collection.The remote data port is compatible with most vending machines and is simple to use and install.  Thismanual is designed to assist in the installation of the remote data port into various vending machines.This manual will be revised periodically to ensure technical accuracy as more machines becomeavailable for retrofitting.The system is available in two options:1. Cash Only  - Monitors cash sales only.2. Full Option- Monitors cash sales and product vends.PRODUCT FEATURES•Optional Mounting Bracket•Linear Motor Monitoring•Matrix Motor Monitoring•Status LED•DEX JackNominal Voltage: 24-34VDCINTERFACES SUPPORTED•Micromech Interface•Pulse & Serial Bill Validator•ACD (Accumulated Credit Display)•Cash Counter1301 Wilson DriveWest Chester PA 19380www.meieasitrax.comModel:Part No.:Serial No.:Voltage: 24-34VDC, 0.5AMPS
Technical Support 1-800-345-8172                                 Remote Data Port  Page-4www.meieasitrax.com                                                                       Revision G1CONFIGURATIONThe remote data port will be shipped with factory default settings.  Each remote data port will requiremachine specific configuration using an MEI Support Tool.  See MEI Easitrax Remote Data PortConfiguration manual for instructions.REMOTE DATA PORTThe remote data port is the core of the audit retrieval system.  It allows for easy retrieval of cashtransactions and/or product vending cycles. The remote data port has five connection points forinterfacing the port directly or indirectly through data pods to the vending machine.PRODUCT OVERVIEWSERIAL NUMBER CONFIGURATIONWWYLCCPPPPPWW - Week Manufactured (01 through 52)Y-  Year Manufactured (2 for 2002)L-  Manufacturing LocationCC -  Configuration CodePPPPP -  Sequential Production NumberP1 - 215630001      P2 - 215634004         P3 - 215638002      P4 - 215636003      P5 - 215632005DDCMP/Printer   Electronic Lock        Config I/O, Dalla 1 Wire Temp     LMM/MMM/DLMM/DMMM   VMC PrinterDEX            Credit Card Reader         RS485 LAN      HII2 Interface     One Wire InterfaceMDB           Executive Interface (Master)   Optional Battery- Rechargeable     Micromech Coin Mech          Executive Interface (Slave)     Fill Sw. Detector (Req. External I/F)     Printer       Light Detector (Req. External Isolation)    ACD       Cash Counter I/F (Req. Isolation)     Parallel Coin Mech    Bill ValidatorBottom View
Technical Support 1-800-345-8172                                 Remote Data Port  Page-5www.meieasitrax.com                                                                       Revision G1MEI EASITRAX VT 1000 (LMM)The MEI EASITRAX VT 1000  is used when monitoring product vend cycles.  It allows for highvoltage monitoring of linear vend motors, credit line and cash counter.PRODUCT OVERVIEWMEI EASITRAX DATA POD 200 (DMMM)The MEI EASITRAX data pod 200 is used when monitoring product vend cycles. Its voltage source isthe data port. It allows for 5V logic to monitor matrix vend motors.Before Installation¨ Verify that the machine and its components work properly prior to data port installation.¨ Power MUST be removed from the vendor prior to starting the installation.¨ Visually inspect machine cables for defects. Adjust/Replace as needed.¨ Perform a test vend and verify change payback.¨ Locate a position where the data port is easily accessible, make sure that harnesses      will reach pod(s) and that no objects are obstructing the data port DEX Jack.¨ Clear all machine errors.Needed Tools/Supplies¨ Cable Ties (Supplied by MEI)– Black UV stable cable ties and self-adhesive cable tie bases.¨ Cleaning materials for vending machines.¨ General assorted tools such as screwdrivers wire cutters, etc.Required Installation StandardIt is a requirement that all products and cables are securely fastened to the vendor. The installer willneed to provide UV stable cable ties to securely fasten all cables to the vendor.  Any looping of excesscable must be fastened to the vendor and service loops need to be minimized.P1P3P2 Data Port InterfaceLinear MotorCash CounterP1P2 Data Port InterfaceMatrix Motor
Technical Support 1-800-345-8172                                 Remote Data Port  Page-6www.meieasitrax.com                                                                       Revision G1AP 6000 / 7000 Series Snack MachineRemote Data Port InstallationThis machine can utilize the Full Option and Cash Only Option.  If you are utilizing the Full Optionperform steps 1 through 15.Required Components:Description Part NumberMEI EASITRAX Remote Data Port 216173001MEI EASITRAX data pod 200 21366201212 Pin Micromech Cable* 215630006Electro-Mechanical “Stub” Harness 215636003MDB Power Cable 215630001VFM Interface Cable 21497700124V Supply Cable 215631014AP 6000/7000 KitMotor Monitor Cable 215635012APi 7x10 Motor Matrix Cable 214891001APi Series 4k-7k Power Cable 214919001*Note: The 12 Pin Micromech Cable and the VFM Interface Cable can be used with Mars and Coinco Products.Installation Instructions1). Verify proper operation of the payment system.  Perform a vend utilizing the billvalidator and coin mech.2). Power off the vending machine.3). Install the Electro-Mechanical “Stub” Harness (p/n 215636003) to the P4 connectorof the Remote Data Port (Observe orientation of the key. Ridge connector must faceup).4). Install the MDB power cable (p/n 215630001) into the plug marked P1 on the RemoteData Port (Observe orientation of the key. Ridge connector must face up).5). Using supplied Velcro, attach the remote data port (p/n 216173001) to the machine.Make sure that the location of the remote data port does not impede machineoperation.AP-MACHINE INSTALLATIONWARNINGDo Not drill into high voltage wiringwhen drilling any necessary mounting holes.
Technical Support 1-800-345-8172                                 Remote Data Port  Page-7www.meieasitrax.com                                                                       Revision G16) Connect the 12 Pin Micromech Cable (p/n 215630006) from the MEI coin changer tothe Electro-Mechanical “Stub” Harness (p/n 215636003) coming out of the RemoteData P4 Connector.*7) Connect the VFM Interface cable (p/n 214977001) from the bill Acceptor to theElectro-Mechanical “Stub” Harness (p/n 215636003) coming out of the Remote DataPort P4 Connector.*8). Connect the Motor Monitor Cable (p/n 215635012) from the Micromech Cable (p/n215630006) coming from the Coin Mech to the Data Pod 200 (p/n 213662012).9). Connect the APi 7 X 10 Motor Matrix Cable (p/n 214891001) between the Data Pod200 (p/n 213662012) and the Vending Machine. Using supplied Velcro, attach theData Pod 200 to the machine near the data port.  Make sure that the location of theData Pod 200 does not impede machine operation or the closing of the cabinet door.10) Connect the 24V Supply Cable (p/n 215631014) to the MDB power Cable (p/n215630001) coming from the P1 connector on the Remote Data Port.11) Connect the APi Series 4k-7k Power cable (p/n 214919001) from the 24V SupplyCable (p/n 215631014) to the Vending Machine.12). Secure harnesses as required using wire ties.13). Power on the vending machine.  A solid green LED should be visible through the DEXsocket (J1) located on the front of the data port.14). Configure the remote data port by using the Palm-Based MEI EASITRAX RDPInstallation Application.**15). Verify the Remote Data Port installation by using the Palm-Based MEI EASITRAXRDP Installation Application.*Coin Changer & Bill Acceptor:Call our technical support help desk for instructions when connecting to a coinchanger and/or bill acceptor manufactured by a company other than MEI.**Configuration:Details pertaining to the configuration of the Remote Data Port are covered in thesection “Palm-Based Installation Application”.AP-MACHINE INSTALLATION
Technical Support 1-800-345-8172                                 Remote Data Port  Page-8www.meieasitrax.com                                                                       Revision G1AP-MACHINE DIAGRAMPart No.:P1  P2  P3  P4  P5Dex Socket (J1)p/n  215630001p/n  215631014p/n  215636003p/n  215630006CoinMech216173001Bill Acceptorp/n  214977001p/n  215635012Data Pod 200p/n 213662012p/n  214891001VMCp/n  214919001
Technical Support 1-800-345-8172                                 Remote Data Port  Page-9www.meieasitrax.com                                                                       Revision G1DN Single Price MachineRemote Data Port InstallationThis machine can utilize the Full Option and Cash Only Option.  If you are utilizing the Full Optionperform steps 1 through 13.Required Components:Description Part NumberMEI EASITRAX Remote Data Port 216173001MEI EASITRAX VT 1000 LMM 213663003ACD Cable 215634009Electro-Mechanical “Stub” Harness 215636003MDB Power Cable 21563000124V Supply Cable 215631014DN Can KitMotor Monitor Cable 215638007Motor Cable (See Chart on page 12)Note:  The MEI Single Price Changer must have accessory harness p/n (01-12-121) attachedin order for installation.   These instructions are for MEI Single Price Coin Changer only.Installation Instructions1). Verify proper operation of the payment system.  Perform a vend utilizing the billvalidator and coin mech.2). Power off the vending machine.3). Install the Electro-Mechanical “Stub” Harness (p/n 215636003) to the P4 connectorof the Remote Data Port (Observe orientation of the key. Ridge connector must faceup).4). Install the MDB power cable (p/n 215630001) into the plug marked P1 on the RemoteData Port (Observe orientation of the key. Ridge connector must face up).5). Using supplied Velcro, attach the remote data port (p/n 216173001) to the machine.Make sure that the location of the remote data port does not impede machineoperation.DIXIE-MACHINE INSTALLATIONWARNINGDo Not drill into high voltage wiringwhen drilling any necessary mounting holes.
Technical Support 1-800-345-8172                                 Remote Data Port  Page-10www.meieasitrax.com                                                                       Revision G16). Installing the ACD cable (p/n 215634009):-Connect the 6 pin ACD connector at the end of the MEI coin mech harness to themating 6 pin connector on the ACD cable tap.*-Connect the ACD Cable tap connector marked P3 to the mating 10 pin connector ofthe Electro-Mechanical “Stub” Harness (p/n 215636003) that is already attached to P4of the Remote Data Port.*7). Connect the Motor Monitor Cable from the Electro-Mechanical “Stub” Harness (p/n215636003) to the VT1000 LMM (p/n 213663003).8). Connect the 24V Supply Cable (p/n 215631014) between the MDB Power Cable (p/n215630001) and the VT1000 LMM (p/n 213663003).9). To complete connection, pick appropriate Motor Cable, based on machine model, fromDixie Narco table on page 12. Use this Motor Cable to connect from the vendingmachine door to the 16 pin connector on the VT1000 LMM.10). Secure harnesses as required using wire ties.11). Power on the vending machine.  A solid green LED should be visible through the DEXsocket (J1) located on the front of the data port.12). Configure the remote data port by using the Palm-Based MEI EASITRAX RDPInstallation Application.**13). Verify the Remote Data Port installation by using the Palm-Based MEI EASITRAXRDP Installation Application.* Coin Changer:Call our technical support help desk for instructions when connecting to a coinchanger manufactured by a company other than MEI.**Configuration:Details pertaining to the configuration of the Remote Data Port are covered in thesection “Palm-Based Installation Application”.DIXIE-MACHINE INSTALLATION
Technical Support 1-800-345-8172                                 Remote Data Port  Page-11www.meieasitrax.com                                                                       Revision G1DIXIE-MACHINE DIAGRAMPart No.:P1  P2  P3  P4  P5Dex Socket (J1)p/n  215630001p/n  215631014p/n  215636003p/n  215634009CoinMechVT 1000 LMMp/n 213663003Machine DoorHarness( From Key Table p.12)16 Pin Connector216173001p/n  215638007Bill Acceptor
Technical Support 1-800-345-8172                                 Remote Data Port  Page-12www.meieasitrax.com                                                                       Revision G1KEY:90 = Series 90 213581001Rd = Reduced SplitRs = RS SEQUENCERTr = Triple Split 213594001Ts = TS SEQUENCER 21513501710 = Ten Clm (2x15 pin)10s = TC SEQUENCER 215133018Make/model Qualifier DoorCable InstalledCableDN – 8 803812110.11 Tr TrDN – 7 803812150.11 Tr TsDN - 7 803 803812150.11 Tr TsDN – 7 803812150.11 Tr TsDN – 6 803812340.01 Tr TrDN - 5 603 803812350.01 Tr TsDN - 5 603 803812370.01 Tr TsDN – 6 803812380.01 Tr TrDN – 5 803812540.01 Tr TrDN - 7 803 803815740.01 Tr TsDN – 9 803818540.01 10 10sDN –10 803818550.01 10 10DN – 8 803819180.01 Tr TrDN – 6 803819190.01 Tr TrDN –10 803819220.01 10 10DN – 8 803820440.01 Tr TrDN - 7 803 803820450.01 Tr TsDN – 8 803820460.01 Tr TrDN – 6 803821050.01 Tr TrDN – 5 803821410.01 Tr TrDN - 7 803 803822920.01 Tr TsDN - 7 803 803822920.11 Tr TsDN – 6 803823320.01 Tr TrDN – 6 803823320.11 Tr TrDN – 8 803823610.11 Tr TrDN – 6 803825890.01 Rd 90DN - 7 803 803825980.01 Rd RdDN – 8 803826000.01 Rd 90DN – 8 803826030.01 Rd 90DN - 7 803 803826670.01 Rd 90DN - 7 803 903828330.31 Rd 90DN - 7 803 903829040.31 Rd 90DN – 8 903829050.11 Rd 90DN – 8 903829060.11 Rd 90DN - 7 803 903829070.11 Rd 90DN – 8 903829080.11 Rd 90DN – 10 903829180.21 Rd 90KEY:90 = Series 90 213581001Rd = Reduced SplitRs = RS SEQUENCERTr = Triple Split 213594001Ts = TS SEQUENCER 21513501710 = Ten Clm (2x15 pin)10s = TC SEQUENCER 215133018Dixie Narco Motor Cable ChartDIXIE-MACHINE INSTALLATION
Technical Support 1-800-345-8172                                 Remote Data Port  Page-13www.meieasitrax.com                                                                       Revision G1RMI 2000 / 8050MEI EASITRAX Remote Data Port InstallationThis machine only utilizes the Cash Only Option.Required Components:Description Part NumberMEI EASITRAX Remote Data Port 216173001MEI EASITRAX VT 1000 LMM 213663003ACD Cable 215634009Electro-Mechanical “Stub” Harness 215636003MDB Power Cable 21563000124V Supply Cable 215631014115V Power Tap Cable 215633013Installation Instructions1). Verify proper operation of the payment system.  Perform a vend utilizing the billvalidator and coin mech.2). Power off the vending machine.3). Install the Electro-Mechanical “Stub” Harness (p/n 215636003) to the P4 connectorof the Remote Data Port (Observe orientation of the key. Ridge connector must faceup).4). Install the MDB power cable (p/n 215630001) into the plug marked P1 on the RemoteData Port (Observe orientation of the key. Ridge connector must face up).5). Using supplied Velcro, attach the remote data port (p/n 216173001) to the machine.Make sure that the location of the remote data port does not impede machineoperation.6). Installing the ACD cable (p/n 215634009):-Connect the 6 pin ACD connector at the end of the MEI coin mech harness to themating 6 pin connector on the ACD cable tap.*-Connect the ACD Cable tap connector marked P3 to the mating 10 pin connector ofthe electromechanical “Stub” harness (p/n 215636003) that is already attached to P4of the Remote Data Port.7). Secure the ACD harness using wire ties.RMI-MACHINE INSTALLATIONWARNINGDo Not drill into high voltage wiringwhen drilling any necessary mounting holes.
Technical Support 1-800-345-8172                                 Remote Data Port  Page-14www.meieasitrax.com                                                                       Revision G18). To connect power to the Remote Data Port, make the following connections:Plug in the 6 pin MDB end of the 24V supply cable (p/n 215631014) into the MDBconnector on the MDB power cable (p/n 21563001).Using the supplied 3M J-hook strips, attach the VT 1000 LMM module (p/n213663003) near the top hinge of the machine’s door. Make sure that the location ofthe VT1000 LMM does not impede machine operation.Connect the 2 pin plug of the installed 24V supply cable (p/n 215631014) to the 2 pinconnector on the front, left side of the VT1000 LMM (p/n 213663003).With the latch facing up, connect the 16 pin connector of the 115V power tap cable(p/n 215633013) into the VT1000 LMM at the front, center opening.On the vending machine, separate the 2 pin connector to the light transformer locatedon the inside part of the machine’s roof. The remaining end of the installed 115Vpower tab has a male and female connector that will mate with the now separated lighttransformer connectors on the inside part of the machine roof.9). Power on the vending machine.  A solid green LED should be visible through the DEXsocket (J1) located on the front of the data port.10). Configure the remote data port by using the Palm-Based MEI EASITRAX RDPInstallation Application.**11). Verify the Remote Data Port installation by using the Palm-Based MEI EASITRAXRDP Installation Application.* Coin Changer:Call our technical support help desk for instructions when connecting to a coinchanger manufactured by a company other than MEI.**Configuration:Details pertaining to the configuration of the Remote Data Port are covered in thesection “Palm-Based Installation Application”.RMI-MACHINE INSTALLATION
Technical Support 1-800-345-8172                                 Remote Data Port  Page-15www.meieasitrax.com                                                                       Revision G1RMI-MACHINE DIAGRAMPart No.:P1  P2  P3  P4  P5Dex Socket (J1)p/n  215630001p/n  215631014p/n  215636003p/n  215634009CoinMechVT 1000 LMMp/n 213663003115V Supplyfrom VMCMale ConnectorFemale Connectorp/n  21563301316 Pin Connector Female LightTransformer Connector Male LightTransformer Connector216173001
Technical Support 1-800-345-8172                                 Remote Data Port  Page-20www.meieasitrax.com                                                                       Revision G1USA, (902-928Mhz) -FCC ID: QP8-MEI915WLAN“This device complies with Part 15 of the FCC Rules. Operation is subject to the following twoconditions: (1) this device may not cause harmful interference, and (2) this device must acceptany interference received, including interference that may cause undesired operation.”“Warning: Changes or modifications to this unit not expressly approved by the partyresponsible for compliance could void the user’s authority to operate the equipment.”Canada, (902-928Mhz) -Canada: 1297B-MEI915WLAN“This Class B digital apparatus complies with Canadian ICES-003.”“Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada.”“Operation is subject to the following two conditions: (1) this device may not causeinterference, and (2) this device must accept any interference, including interference that maycause undesired operation of the device.”“This device has been designed to operate with an antenna having a maximum gain of 0 dB.Antennas having a higher gain is strictly prohibited per regulations of Industry Canada. Therequired antenna impedance is 50 ohms.”COMPLIANCE

Navigation menu