Features
MJPEG with two-way communications;
P2P iOS / Android support;
SpO2 and Pulse Rate (PR) measurement;
Room temperature measurement;
Lullabies; Pictures; Video
Night light.
Check list
One User Manual
One 4G micro SD card
One baby unit
One USB connected adapter
One Pulse Oximeter (including one SpO2 probe)
Two batteries
Overview of front side
Overview of back side
Camera
Infrared light
Microphone
Night light
Pedestal
Night light button
1. Power switch 2. Micro SD card socket
3. USB interfaces 4. Sarus light
5. Power light 6. Speaker
7. Temperature sensing antenna
Photoresistor: Senses light automatically switching
from day to night.
Connection to internet
Operation procedures:
Step 1: Install the software IPC100, boot up the
software and tap "new camera"→ tap "add wireless
wizard"tap "next"→ tap "WIFI settings" and will
search WIFI as shown in below figure:
NOTE:
User name: IPCAM_XXXXXX;
Password: 88888888
Please go back to operating page when this step
finished.
Step 2: Click "Next" "Next" as shown in below
figure.
The password is default and tap next.
Step 3: Select user's wireless router and enter the
password and tap "Next"→ "Next" searching network
(connect the mobile phone to the WIFI), and appears the
figure as below figure:
Tap "Save", the signal icons " " in blue indicate
well connected to the WIFI, as shown in below
figure:
You can operate the IPC100 and remote control the
pan tilt.
Step 4: While the IPC100 connected to WIFI or
another mobile phone adds IPC100. Open the software
of IPC100, to tap "add new camera"→ "LAN
searching" (make sure no camera in the camera list),
as shown in below figure:
Tap "IPC-E8ABFXXXX" and then "Save", the
password is default blank. The signal icons " "
in blue indicate well connected to the WIFI, as shown
in below figure:
You can operate the IPC100 and remote control the
pan tilt.
(Notice: If the baby monitor needs to connect a new
wireless router, please reset the baby monitor: Long
press the reset button at the bottom of baby monitor
till the night light on)
1. Temperature: tap the temperature value to change the
unit Centigrade and Fahrenheit.
2. Photos 3. Video recording 4. Photograph
5. Previous song 6. Play & pause 7. Next song
8. Volume up 9. Volume down 10. MP3
11. Talkback 12. Monitor 13. Nightlight
14. Time 15.SpO2 & PR
Warning:
To prevent strangulation with the power cord, always
keep the baby unit and the power cord out of baby's
reach, at least 1metre/3.5 feet away. Do not use
extension cords.
Diagram
Install mobile phone software
Step 1: Connect the mobile phone to WIFI.
Step 2: Set the regional Network: open the software
--Refresh--Searched IP --Edit.
Step 3: Preview--Save--save
Step 4: Set the P2P network: P2P-please click here to
add the camera.
Step 5: Click "LAN search", if the mobile phone ID
is not within the LAN, ID input should be:
Step 6: Click the red square input the password
(888888)→ save.
Step 7: Click the camera
Step 8: The available settings for camera are audio
frequency, talkback, video recording, and resolution
value, with the function of photographing, cruise,
mirror and flip. You can switch among the camera
list, video list and instruction at the bottom of the
screen.
Remark: the video from camera list is connected to
the regional network and P2P is connected the outside
network.
Technical parameters
Model
IPC100
Description
IP camera for baby monitoring
Modulation
MJPEG with 2 way audio
Frames per second
15~25/s
SpO2 Range
35% - 100%
SpO2 Alarm
Low limit 90%
Pulse Rate Range
30bpm 240bpm
Pulse Rate Alarm
High limit 160bpm
Low limit 70bpm
APP / APK
Android/iOS
Infrared night view
Yes
AC adapter
6V 500mA
Walkie-talkie function
Yes
Night light function
Yes
Temperature detect
Yes
Monitor with motor
Yes
Other functions
Smart size, nice appearance, easy installation,
long time monitoring.
Multiple clients on mobile and computer, easy
and convenient.
Real-time audio and video monitoring and clear
transmission.
Alarm function: when the measured SpO2 or
Pulse Rate value exceeds the preset alarm limit,
then the smart phone will activate the audible and
visual alarm indications.
Infrared night vision function, you can see your
baby even he/she is in the darkness.
Pleasing nightlight and lullaby to comfort baby.
Especially suitable for infant care, elder care,
monitoring, etc., it can also be used for general
real time security monitoring.
Cautions:
This product is intended as an aid. It is not a
substitute for responsible and proper audit
supervision and not intended for use as a medical
monitor.
Please do not use other power adapters that may
not fit this product configuration.
Please do not expose the baby monitor to extreme
cold, heat, wet or direct sunlight.
Make sure the baby unit and the adapter cord are
always out of reach of the baby, at least 3
feet/1meter away from the baby or crib, to avoid
a possible strangulation hazard.
Never cover the baby unit or parent unit with
anything such as a towel or a blanket. Turn off
unit prior to cleaning.
Troubleshooting
Problem: Power indicator light not working.
Possible cause: Does not switch on; Power is not
getting to the unit; Low batteries.
Solution: Turn on the units; Make sure the units are
connected to the power supply; Replace the
batteries.
Problem: Power indicator flashing.
Possible cause: Not connected well with adapter;
Low batteries.
Solution: Make sure well connected; Replace the
batteries.
Problem: Parent unit makes loud noises.
Possible cause: Units are too close together; Volume
dial on parent unit may be too high.
Solution: Move the parent unit at least 3 feet/1meter
away from the baby unit; Turn down the volume on
the parent unit.
Problem: Weak sound may be coming from parent
unit.
Possible cause: Volume on parent unit or set too low
or muted.
Solution: Turn up the units or move closer to each
other.
Problem: Units may be too far from each other.
Possible cause: No signals between units.
Solution: Move the units closer to each other.
Supplementary Operation
Instruction for Pulse Oximeter
Instructions for Connection
Insert the sensor tips into the slots on the probe
holders. Place the sensor tip labeled “LED” into the
stationary probe holder on the silicone wrap belt, and
place the sensor tip labeled “PD” into the sliding
probe holder, as illustrated in Figure 1 and Figure 2.
Figure 1 Probe tip and holder
Figure 2 Y-type SpO2 Sensor with Rubber Wrap
NOTE: Make sure that the silicone button seats fully
into the hole in the back of the probe holder.
Wrap the oximeter on the leg near ankle with its
belts and position the front panel to a proper place
for convenient operation, as shown in Figure 4.
Wrap up the Y-type sensor onto the babys foot by
the rubber wrapper, as illustrated in Figure 3. Make
sure the alignment of the light-emitting tip (LED)
and the photo- detecting tip (PD) are aiming at each
other, then thread the end of wrap belt through the
outside slots on the probe holders and tighten the
rubber belt with proper force. The final placement is
shown in Figure 4.
Figure 3 Sensor wrapping up
Figure 4 Placement of the Oximeter and the Sensor
It's recommended that wrapping up the sensor onto
the baby's first toe if the foot is too thick to be
tighten, as shown in figure 5.
IMPORTANT: The sensor
connection is critical for the signal
strength and quality. Position LED
and PD facing each other on
opposite sides, so that the light
beam is transmitted as vertically as
possible and the light path is as
short as possible.
Pulse Oximeter
Y-type SpO2
Sensor with
Rubber
Wrapper
Instructions for Operation
After all connection have been completed, press the
Power Button ( ) for 3 seconds to power on the
oximeter, referring to below figure. When the
oximeter is powered up, the Power Indicator (yellow
lamp ) will light constantly. If the heart beat is
detected, the Heartbeat Indicator (red lamp )
flashes according with the heart rate. At the same
time the oximeter sends the measured data (SpO2
and PR) to Baby Monitor in a given time interval via
wireless communication, and the SpO2 and PR value
will be displayed on the terminal side of Baby
Monitor.
Appearance of the Pulse Oximeter
NOTES:
1. The oximeter has no automatic power-off function.
Press the Power Button for 3 seconds to turn it off
after the end of use each time.
2. If the Power Indicator flashes it means the battery
voltage is low for the oximeter, please replace the
batteries.
Distributed by:
eH4H LLC
1200 Abernathy Road, Suite 1700, Atlanta,
GA 30328
Website: www.Dormebaby.com
Tel: 888-741-2224 ext. 2
Fax: 832-442-4000
For mobile phone with Android system, please go to
Google Play and search "Dorme Baby" to download
and install the responding application;
For mobile phone with iOS system, please go to APP
Store and search "Dorme Baby" to download and
install the responding application.
FCC Caution.
§ 15.19 Labelling requirements.
This device complies with part 15 of the FCC
Rules. Operation is subject to the following
two conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
§ 15.21 Information to user.
Any Changes or modifications not expressly
approved by the party responsible for
compliance could void the user's authority to
operate the equipment.
§ 15.105 Information to the user.
Note: This equipment has been tested and
found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful
interference in a residential installation. This
equipment generates uses and can radiate
radio frequency energy and, if not installed
and used in accordance with the instructions,
may cause harmful interference to radio
communications. However, there is no
guarantee that interference will not occur in a
particular installation. If this equipment does
cause harmful interference to radio or
television reception, which can be determined
by turning the equipment off and on, the user
is encouraged to try to correct the interference
by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the
equipment and receiver.
-Connect the equipment into an outlet on a
circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced
radio/TV technician for help.
*RF warning for Mobile device:
This equipment complies with FCC radiation
exposure limits set forth for an
uncontrolled environment. This equipment sh
ould be installed and operated with
minimum distance 20cm between the radiator
& your body.

Navigation menu