Crest Audio Cki Series Users Manual Brochure V2

CKi Series to the manual 4171c28c-8d08-439e-a971-265bb928385d

2015-02-05

: Crest-Audio Crest-Audio-Cki-Series-Users-Manual-531532 crest-audio-cki-series-users-manual-531532 crest-audio pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadCrest-Audio Crest-Audio-Cki-Series-Users-Manual- CKi-brochure-v2  Crest-audio-cki-series-users-manual
Open PDF In BrowserView PDF
CKi Series
Power Amplifiers

CKi
SERIES

Introduction
Crest Audio, the first company to offer computer controlled amplification now raises the bar.
With the introduction of the CKi series of amplifiers,
Crest Audio has added many standard features that
other manufactures either charge additional for or
don’t offer at all.Whether your requirements are simple or extremely complex, CKi series amplification systems are perfect for permanent installations of any
size. As with all Crest Audio amplifiers, reliability and
sonic performance are the most important factors in
the amplifiers design.
With three different types of amplifiers, two
add-on modules, and plug in options, the CKi series of
amplifiers allows you the flexibility to install exactly
what you need to do the job. CKiS amplifiers are the
low impedance series, CKiV units are specially
designed for distributed systems, and CKiX is the 100
Volt, transformer isolated version of the amplifier.
Module options include NxEtherNet and
NxCobraNet cards which can be ordered installed in
the amplifiers or easily added later. The NxEtherNet
card is an ethernet based network module that enables
the amplifier to communicate with NexSys and
MediaMatrix software for control and reporting of
amplifier functions by remote computer control. The
NxCobraNet card incorporates all of the functionality
of the NxEtherNet module plus the ability to decode
2 channels of CobraNet digital audio.
CKi amplifiers standard features include
sequential turn-on / turn-off (STO), input gain switch
User resettable AC
mains breaker

Sequential Turn-on
connections

2

Barrier strip output
connectors

Fault I/O for connection to monitoring systems

(x20, 0dB / .775V, and x40), mode switch (stereo, parallel, bridged), ground lift switch, and removable detented potentiometers. In addition, status LEDs are provided on the front and rear of the unit for signal, ACL,
IGM, and protect conditions. Power monitoring is by
two LEDs, one which displays that power is present to
the amplifier and one that signifies that the amplifier is
operating (Active LED). Input is through 3-pin euro
style connectors and output is provided on 4 position
barrier strips. Fault I/O closure outputs are provided
on a three pin euro-style connector to alert external
supervisory systems, such as a control room display, if
an amp problem exists.
Amplifier options available include NxDSP
processor plug-in board and the transformer input isolation board. The NxDSP option allows control of
speaker related functions such as delay, EQ, and limiting.The transformer isolation board helps to eliminate
problems with improper audio grounding and impedance mis-matches between equipment.
Crest TourClass protection includes active clip
limiting (ACL) which prevents speaker damage by providing gentle gain reduction at the onset of clipping.
Instantaneous gain modulation (IGM) monitors speaker loads to detect conditions that overstress amplifiers. Autoramp gradually increases gain to the preset
amplifier setting when the amplifier is turned on.
Backed by Crest Audio’s 5 year warranty* and
exceptional service departments, CKi amplifiers are a perfect choice for all of your fixed installation requirements.

Detented rear panel
attenuators with
removable knobs

Module bay for NxCobraNet or
NxEthernet modules

Mode switch for Status LEDs make 3 pin euro Selectable input
sensitivity
in-rack troustyle input
stereo, parallel, and
Signal ground
bleshooting a
connectors
bridged mode
switch
breeze
operation

*USA, Canada, and many other countries.

CKiS Series
Designed to drive low impedance loads

Model

Stereo
8Ω

2Ω

Bridged
8Ω

4Ω

4Ω

Class

RMS

Maximum

CKi100s

60W

90W

N/A

180W

N/A

AB

22V

31V

CKi200s

120W

175W

N/A

350W

N/A

AB

32V

45V

CKi400s

255W

320W

N/A

510W

N/A

AB

56V

64V

CKi800s

440W

670W

N/A

880W

N/A

AB

64V

90V

CKi800-2s

420W

670W

870W

880W

1740W

H

64V

90V

CKi1200s

630W

940W

1130W

1880W

2260W

H

78V

110V

CKi1600s

815W

1130W

1440W

2260W

2880W

H

90V

127V

power ratings are Watts per channel, both channels driven, 1kHz, 0.02% THD+N

Model

1/8 power

1/3 power

Rack U

Weight

Idle (120V)

1/8 Power

1/3 Power

Maximum*

CKi100s

612

780

2

26.63 / 12.09

.5A

1.65A

2.3A

3.5A

CKi200s

1100

1380

2

29.44 / 13.37

.6A

3.0A

4.2A

6.5A

CKi400s

2120

2820

2

30.44 / 13.82

.7A

5.8A

8.6A

12A

CKi800s

3584

4700

3

50.20 / 22.80

.7A

10.0A

14.8A

15A

CKi800-2s

1210

3600

3

70.65 / 32.08

.7A

4.2A

12.1A

20A

CKi1200s

3164

5040

4

70.65 / 32.08

1.3A

9.6A

17.3A

26A

CKi1600s

3154

6525

4

70.65 / 32.08

1.3A

10.0A

22.6A

30A

lbs / kg

* circuit breaker rating, 120 V / 4 Ω

CKiV Series
Designed specifically for 70 Volt distributed applications

Model

70.7 Volt

140 Volt*

Class

RMS

Maximum

CKi100v

50W

100W

AB

92V

130V

CKi200v

100W

200W

AB

92V

130V

CKi400v

200W

400W

AB

92V

130V

CKi800v

400W

800W

AB

92V

130V

CKi1600v

800W

1600W

H

92V

130V

CKi2400v

1200W

2400W

H

92V

130V

70.7 Volt power rating is Watts per channel, both channels driven, 20Hz -20kHz, 0.02% THD+N
*bridged mono operation
Model

1/8 power

1/3 power

Rack U

Weight

Idle (120V)

1/8 Power

1/3 Power

Maximum*

CKi100v

269

304

2

25.26 / 11.47

.5A

.76A

1.02A

2.5A

CKi200v

816

932

2

27.20 / 12.35

.5A

2.2A

2.83A

4.2A

CKi400v

1304

1634

2

30.66 / 13.92

.6A

3.6A

5.1A

7.0A

CKi800v

2540

3263

3

50.20 / 22.80

.8A

7.0A

10.1A

15A

CKi1600v

2600

5000

4

70.65 / 32.08

1.3A

8.0A

17.0A

30A

CKi2400v

3100

6500

4

70.65 / 32.08

1.3A

10.0A

23.0A

30A

lbs / kg

4

* circuit breaker rating, 120 V

CKiX Series
Engineered for 100 Volt transformer isolated systems

Model

Stereo
50 Volt*

70.7 Volt*

100 Volt

Bridged
200 Volt

Class

RMS

Maximum

CKi150x

75W

75W

75W

150W

AB

105V

150V

CKi300x

150W

150W

150W

300W

AB

105V

150V

CKi500x

250W

250W

250W

500W

AB

105V

150V

CKi800x

400W

400W

400W

800W

AB

105V

150V

50, 70.7, and 100 Volt power rating is Watts per channel, both channels driven, 40Hz -20kHz, 0.1% THD+N
*50 and 70.7 Volt units are options that must be specified at time of order

Model

1/8 power

1/3 power

Rack U

Weight

Idle (240V)

1/8 Power

1/3 Power

Maximum*

CKi150x

363

427

3

32.00 / 14.55

.25A

.57A

.77A

1.88A

CKi300x

555

1683

3

35.00 / 15.91

.25A

1.6A

2.1A

3.2A

CKi500x

810

1024

3

35.00 / 15.91

.3A

2.2A

3.2A

4.4A

CKi800x

1195

1536

3

57.00 / 25.91

.4A

3.5A

5.2A

7.5A

lbs / kg

*circuit breaker rating, 240 Volt

NxCobraNet Module
Optional Module for NexSys Control and CobraNet Digital Audio

The NxCobraNet® module supports all NexSys control and monitoring functions
as well as delivering two channels of CobraNet digital audio to the amplifier on one ethernet cable. Supported computer controlled NexSys functions include gain, sequential
power, and real time load monitoring.Amplifier monitoring includes input and output level
(VU), DC protect, thermal protect, IGM, clip status, power state,AC mains, heatsink temperature, gain selection, ground lift status, and audio return.
The LED display allows easy in rack readout and monitoring of temperature,
gain, AC voltage, IP address, amplifier ID, as well as CobraNet bundle and channel status.
Individual indicators display fault and mute status by channel as well as ethernet link and
data indicators.
The NxCobraNet module requires no other additions to make it network ready.
The module has an RJ-45 ethernet connection that is made through a Category 5 compliant Neutrik EtherCon connector to ensure a secure connection.
Both the NxCobraNet and the NxEthernet modules can be ordered with CKi
amplifiers or easily installed in the field with two screws and a ribbon cable connection.

NxEtherNet Module
Option Module for NexSys Control of CKi Amplifiers

The Crest Audio NxEthernet module is designed for clients who need the control of
NexSys but do not need the digital audio delivery that the NxCobraNet module provides.

6

NxDSP
Optional DSP for NExSys Control and CobraNet Digital Audio

The Crest Audio NxDSP plug in board
for NxCobraNet and NxEthernet performs
various functions depending on which module
it is used with.
NxEthernet module: provides speaker
processing including limiting, equalization,
speaker alignment, delay and gain.
NxCobraNet module: in addition to
speaker processing the DSP installed in the
NxCobraNet module provides 8 channels of
CobraNet audio decoded to analog outputs
on the back of the module

Input Transformers
Optional Plug-in Input Transformers

Input isolation transformers are available for all CKi amplifiers. The plug- in module
can be specified with Sescom or Jensen isolation transformers.The modules can be installed
in the amplifier if ordered with the amplifiers or
easily added in the field.
FA-CKiXFMRJ-ZZ Jensen transformers
FA-CKiXFMRS-ZZ Sescom transformers

Crest Audio reserves the right to make improvements in manufacturing or design which may affect
specification. Crest Audio specification literature is available in electronic form to qualified users.
Contact Crest Audio Inc. for more information.
©2004 Crest Audio Inc.

Crest Audio Inc.
16-00 Pollitt Dr. Fair Lawn NJ 07410 USA
TEL: 201.909.8700 FAX: 201.909.8744
www.crestaudio.com

