Crestron Electronics MP-FSMIC Wireless Microphone with Frequency Hopping Transmitter User Manual MP FSMIC IG 7166Ar

Crestron Electronics Inc Wireless Microphone with Frequency Hopping Transmitter MP FSMIC IG 7166Ar

Users Manual

Crestron MP-FSMICFreeSpeech™ Wireless MicrophoneInstallation GuideCrestron Electronics, Inc.  Installation Guide - DOC. 716615 Volvo Drive   Rockleigh, NJ 07647  (2030245)Tel: 888.CRESTRON  06.11Fax: 201.767.7576   Specifications subject to www.crestron.com  change without notice.SPECIFICATIONWireless Communication  RF  2.4 GHz ISM Device; 79 Channels FHSS (2402     to 2480 MHz)  IR  38 kHz   Range (typical)  50 ft (~15 m) indoor, subject to site-specific     conditions (requires MP-FS-RX1 or MP-FS-RX2     receiver)*Battery  Battery Type  Lithium Ion Polymer, 3.7 Volt, 180 mAh  Usage per Charge  6 hours   Charging Time  2 hours  Cycle life  >500 cycles (80% capacity)    (Requires MP-FSDS2 docking station/charger)*Environmental  Temperature  41° to 104° F (5° to 40° C)  Humidity  10% to 90% RH (non-condensing)Enclosure  Plastic, matte black, includes magnetic clip for     lapel or lanyard attachmentDimensions  Height  2.10 in (54 mm)  Width   1.00 in (26 mm)  Depth  0.95 in (24 mm)Weight  0.7 oz (20 g)Included Accessory  MP-FS-LANYARD  Lanyard for MP-FSMICAvailable Accessories   MP-FS-RX1  FreeSpeech Single-Channel Wireless Mic Receiver  MP-FS-RX2  FreeSpeech Dual-Channel Wireless Mic Receiver   MP-FS100_PAK  FreeSpeech Single-Channel Wireless Mic System     Package  MP-FS200_PAK  FreeSpeech Dual-Channel Wireless Mic System     Package                MP-FSDS2  FreeSpeech Dual Wireless Mic Docking Station/    Charger   MP-FSTTS  Tabletop Stand for MP-FSMIC                                       DETAILSSPECIFICATIONSSpecifications for the MP-FSMIC are listed in the following table.MP-FSMIC SpecificationsFurther InquiriesIf you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling Crestron® at 1-888-CRESTRON [1-888-273-7876]. For assistance in your region, please refer to the Crestron Web site (www.crestron.com) for a listing of Crestron worldwide offices.You can also log onto the online help section of the Crestron Web site ww.crestron.com/onlinehelp) to ask questions about Crestron products. First-time users will need to establish a user account to fully benefit from all available features.Future UpdatesAs Crestron improves functions, adds new features and extends the capabilities of the MP-FSMIC, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision.Check the Crestron Web site periodically for manual update availability and its relevance. Updates are identified as an “Addendum” in the Download coumn.Crestron FreeSpeech™ systems provide a very simple and affordable solution for adding speech reinforcement as part of a complete classroom media presentation system. Compact and lightweight, the MP-FSMIC can be clipped to a lapel, hung around the neck, or placed in a tabletop stand*. As part of a complete FreeSpeech wireless mic system, the MP-FSMIC affords reliable and hassle-free operation. Simply press the ON button and go.Advanced FreeSpeech RF/IR wireless technology ensures consistent performance with complete freedom of movement — and minimized risk of noise or feedback. The infrared “beacon” signal prevents interference between multiple FreeSpeech systems in adjacent rooms, and even shuts the mic off automatically if the instructor leaves the room with the mic on.An internal rechargeable battery provides six hours of usage to last a full school day. Recharging for up to two MP-FSMICs is handled by the MP-FSDS2 docking station*. DESCRIPTIONMP-FSMIC *Item(s) are sold separately or as part of a MP-FS100_PAK or MP-FS200_PAK system package.*Item(s) are sold separately or as part of a MP-FS100_PAK or MP-FS200_PAK system package..Regulatory ComplianceFederal Communications Commission  (FCC) Compliance StatementIndustry Canada  (IC) Compliance StatementReorient or relocate the receiving antennaIncrease the separation between the equipment and receiverConnect the equipment into an outlet on a circuit different from that to which the receiver is connectedConsult the dealer or an experienced radio/TV technician for helpAs of the date of manufacture, the MP-FS-RX1 and MP-FS-RX2 have been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling.This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Crestron, the Crestron logo, and FreeSpeech are trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. ©2011 Crestron Electronics, Inc. CONNECTORS,CONTROLS &INDICATORS 1  Status  (1) Dual-color green/red LED. Blink patterns show        operational status and battery/charging condition1  2   IR Beacon  (2) Infrared LEDS, transmit operation data to        MP-FSIR IR Beacon Sensor(s)2  3  ON/MUTE  (1) Rocker button, turns wireless mic on and off,        and mutes mic audio  4  VOL  (1) Rocker button, adjusts mic volume when mic is        unmuted, adjusts program (line) volume when mic        is muted  5  ALERT  (1) Push button, triggers alert out relay and/or       alert tone  6  Service Port  Used for firmware upgrade. Only for use by installer  7  Charger Contacts  Connect to contacts in Docking Station/Charger2DESCRIPTION#Connectors, Controls & IndicatorsMP-FSMIC-B-T-1 Overall Dimensions0.95 in(24 mm)2.10 in(54 mm)1.00 in(26 mm)1324 2 576ALERTON MUTE +  VOL  -Return and Warranty Policies  Merchandise Returns / Repair Service 1.  No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number and return address.  2.  Products may be returned for credit, exchange or service with a CRESTRON Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any products returned with an RMA.  3.  Return freight charges following repair of items under warranty shall be paid by CRESTRON, shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser.  CRESTRON Limited Warranty CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touch screen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered.  This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any.  CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse, accidental damage, modification or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number altered, defaced or removed.  This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a third party or made by the purchaser for a third party.  CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty.  Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties.1.  Refer to the Microphone LED Blink Codes chart in the next column.2.  Item sold separately or as part of a MP-FS100_PAK or MP-FS200_PAK system package.INSTALLATIONInstallation of the MP-FSMIC consists of the following:  1.  Connect the power pack supplied with the MP-FSDS2 Dual Docking Station/Charger to line power and then to the docking station. The green LED on the docking station indicates power is applied.  2.  Place the mic in the docking station, and allow it to charge for at least two hours. When the battery is fully charged, the mic's Status LED blinks green.*  3.  Use the included magnetic clip for lapel or lanyard attachment, or place the mic in a tabletop stand. During operation, the mic should be positioned approximately four inches (100 mm) from the speaker's mouth.  Microphone LED Blink Codes**Charge Complete  G G  G G  G G  G G  G GCharge in Progress  R  R  R  R  ROn But Not Paired  G G G G G G G G G G G G G G G G GMuted  GGG  GGG  GGG  GGG  GGGPaired  G  G  G  G  GMissing Beacon While Paired  R  R  R  R  RLow Battery  RG  RG  RG  RG  RGLow Battery & Muted  RGGG  RGGG  RGGG  RGGG  RGGGLow Battery & Missiing Beacon  RR  RR  RR  RR  RRLow Battery & Not Paired  GRGRGRGRGRGRGRGRGRGRGRGRGShutting Off  RRRRRRRRRRRRRRRRRRRRRRRRRR**In the table, G=green; R=red*Refer to the Microphone LED Blink Codes chart in the next column.

Navigation menu